ca2ef737-2017-43ac-95bd-a81f8f87ffb1 | max or min loads are known. In any event—here are the average inputs we’re going to use in
this example.
Let’s assume that we have roughed out the design of our product and have need for a joint
which will be subjected to a concentric, per-bolt tensile load which will cycle between 3,000and 4,000 lbs. We’d like the min... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 481 |
b8212073-764c-4557-8052-4b9a6c92ea4e | using manual torque wrenches, and it will be used at room temperatures only. Here, then, are
our inputs:
AS ¼0.1419 in.2(from Appendix E)
DFP ¼28% of FP(10% from embedment plus 18% average relaxation
through elastic interaction)
LX ¼4,000 lbs
LXmin ¼3,000 lbs
s ¼+30%
FKn ¼0.2
sA ¼18 ksi (from Table 2.11)
syof bolts ¼13... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 482 |
415baea2-72af-4534-8402-4ae2be8aff80 | Now we’re ready to compute min and max assembly preloads (Equations 18.5 and 18.6)
MinFJ¼DFJþDFPrqdþDFP/C0/C1
¼(3,200 þ1,000 þ2,583 )¼6,783 lbs
MaxFJ¼aAMinFJ¼1:86(6,783 )¼12,616 lbs
18.5.2.2 Static Strength of the BoltsAre the bolts strong enough? From Equation 18.7
0:9F
y¼0:9(18,447 )¼16,602 lbs
This is greater than M... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 482 |
55e6bc0c-9d11-4750-8b73-8453f96721b0 | That’s only 73% of the yield strength ( Fy) of the bolt, leaving a 13% safety factor. Our choice
of a1=2in Grade 8 bolt may not be optimum, but it certainly appears to be acceptable.
18.5.2.3 Fatigue Strength
Next we analyze the fatigue situation, using Equation 18.9
FKnLX/C0LXmin ðÞ =2/C20sA
0:2(4000/C03000 )=2¼100psi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 483 |
7bd71227-85d2-40ea-bda0-97e157dc64cb | P¼Aflats/C0Adiam
AP¼0:442/C00:196¼0:246in:2
The yield strength of the joint material is 30 ksi, so we’ll call that the maximum allowable
contact pressure, PG[from Equation 18.14]
APPG¼0:246(34,000 )¼8,364 lbs
0:9MaxFJ¼0:9(12,616 )¼11,354 lbs
APPGis less than 0.9 Max FJand so the contact stress exceeds the limits impose... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 483 |
e7106bdf-5e60-4ba9-9aea-822b24c1d501 | PPGto 20,040 lbs,
well above the 0.9 Max FJvalue of 11,354 lbs.
Nogasketortemperaturechangeorshearloadsoreccentricloadsareinvolvedhere,sowe’re
done. As you can see, the procedure is easy to use. But estimating the values to be used for theinput data—loads and things—can require some effort and some engineering judgment... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 483 |
997684bf-ce12-4bd8-bed1-64c702d056df | Chapter 4 to check length of engagement etc. if we’re planning to use the bolts in tapped
holes, especially in soft materials. For example, one rule of thumb I’ve heard suggests that thelength of engagement should be at least two times the bolt diameter if a steel bolt is to be usedin a hole tapped in an aluminum joint... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 484 |
324b7747-fc43-4b64-9244-74ac1aa2b0b8 | 8:1 or more, it will never self-loosen’’ or ‘‘We always want the joint-to-bolt stiffness ratio to be
10:1 or greater.’’ In general, we want to avoid such poor energy storage parts as short, stiffbolts; composite or soft joint materials; etc.
18.6.3 A CCESSIBILITY
We want a minimum of 60 8in which to swing a wrench, and... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 484 |
d314d833-c387-49f1-a644-05291ace2512 | rather than with tension joints. See Chapter 19 for more on shear joint design.
18.6.5 L OADMAGNIFIERS
We want to avoid things which magnify the loads seen by the bolts. The most common
sources of this problem are prying, as illustrated in Figure 11.4, and eccentric shear loads,which will be discussed in Chapter 19. (S... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 484 |
beae0805-0db9-4b4f-850e-7701b3117547 | 18.6.7 D IFFERENTIAL EXPANSION
Differential expansion can create a significant and simultaneous increase—or decrease—inboth bolt tension and the clamping force of the joint. We can at least reduce the effects byusing bolts and joint members made of materials having similar coefficients of thermalexpansion. It helps if ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 484 |
15db308a-6876-47d0-aa2b-a933b51d23c1 | 438 Introduction to the Design and Behavior of Bolted Joints | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 484 |
ed39fbd3-6c59-4ab6-b43d-569571908618 | designers, for example, estimate the stresses in flange fillets. Studies have been made of ways
to combat bending stresses placed on certain types of aerospace joints [4]. And the PVRC istrying to quantify the effects of bending moments on gasketed, flanged joints. Excess stresscan cause shear joints to tear out, etc. ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 485 |
56dd9589-b4ac-4b07-b4d2-30c26c0620f5 | 18.6.10 H OLEINTERFERENCE
We want to avoid inadvertent interference between the bolts and clearance holes in jointmembers, by careful dimensioning of hole locations, sizes, etc. because hole interference canabsorb a substantial portion of assembly preload. If interference is desired or unavoidable weshould specify that... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 485 |
d5e3ada6-b34b-4076-a03d-1c9e7bc94b6e | 1=2in. diameter bolt will do the job
we might well decide to use a5=8in. or3=4in. one to cover the uncertainties.
18.6.12 S ELECTING A TORQUE TO BEUSED AT ASSEMBLY
VDI doesn’t tell us, specifically, how to pick an assembly torque, but they give us the necessaryinformation to do this. The target preload would be the mid... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 485 |
9be62f49-a790-47bc-b0fd-0b17a3e722b3 | D¼nominal diameter of the fastener (in., mm)
FPa¼preload to be used at assembly (lb, N)
Continuing the example of Section 18.5:
FPa¼(1þ1:86)(6783 )=2¼9700 lbs
T¼0:2(0:5)9700¼970in:-lbBickford/Introduction to the Design and Behavior of Bolted Joints 8176_C018 Final Proof page 439 26.7.2007 1:55pm Compositor Name: VAmoud... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 485 |
c27cc4f2-f521-415a-8748-1e81b599260e | And that’s it! If we do all of the things described in this section and in Section 18.4, we’ll end
up with better-designed bolted joints than most of those which are already out there. Whocould ask for anything more?
EXERCISES
This chapter is basically a recapitulation of most of the previous chapters, so the answers t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 486 |
be6a1218-bac0-40f8-85cd-4785713862e8 | 4. The bolts will be lubricated with moly paste, for better control of preload, and will be
tightened with a torque wrench. What torque will you specify?
5. What range of preload would you expect to encounter when that torque is applied to a
production quantity of this joint; assuming perfect tools and operators?
6. Wh... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 486 |
b8f7074b-b7c4-4c5a-bfeb-87ece376ce1b | production quantity of these bolts?
10. With the estimated minimum in-service tensile stress in mind, what possible bolt or joint
failure modes must you consider, and under what service conditions?
11. What are some obvious things you can do if you are concerned about one or more of
these failure modes?
REFERENCES
1. J... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 486 |
5e739a4e-a6fd-49ce-a124-1fe45c666b20 | 3. McNeill, W., A. Heston, and J. Schuetz, A study of factors entering into the calculation for
connecting rod joints according to the VDI 2230 guidelines, VDI Berichte No. 766, 1989.
4. Baumann, T.R., Designing safer prestressed joints, Machine Design , pp. 39ff, April 25, 1991.
5. Eccles, W., Bolted joint design, Eng... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 486 |
b619873e-a238-4e09-9198-49f15157cc9a | Joint design, Prepared by the Technical Information Staff of the Industrial Fastener Institute, Machine
Design , p. 12, September 11, 1969.
Junker, G.H., Principle of the calculation of high-duty bolted joints, SPS, Jenkins town, PA.
Osgood, C.C., How elasticity influe nces bolted joint design—part 1, Machine Design , ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 487 |
ac2288dd-e3a3-4fbd-99ee-597813b9e700 | (VDI), Berlin, West Germany, October 1977.
B. Pressure Vessel and Piping Joints
ASME Boiler and Pressure Vessel Code , ASME, New York, 1983. Section III—Division 1, Subsection
NB-Design of Class 1 components (those contained in the reactor coolant boundary). See
especially sections NB3231 and Appendix E.
Section III—Di... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 487 |
6a3d3936-4aa0-47c1-90d6-6a2e7aaffda1 | Bulletin 314, Welding Research Council, New York, May 1986.
Petrie, E.C., The ring joint; its relative merit and application, Heating ,Piping and Air Conditioning ,
vol. 9, no. 4, April 1937.
Reddy, M.D. and B.S. Nau, Factors affecting the design of large flanged joints and joint seals for
chemical plant, British Hydro... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 487 |
df8b7306-2dbc-4903-82f2-35bcf5b73f51 | Laboratory, Oak Ridge, TN, September 30, 1976.
Wesstrom, D.B. and S.E. Bergh, Effect of internal pressure on stresses and strains in bolted-flanged
connections, ASME Transactions , p. 121, 1951.
Webjorn, J., The bolted joint, a series of problems, Dissertation No. 130, Institute of Technology,
Linkoping, Sweden, 1985.
... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 487 |
ef3bada5-ab42-40cb-8062-495a5acdb716 | ed., Wiley, New York, 1987.
Manual of Steel Construction , 8th ed., American Institute of Steel Construction (AISC), Chicago, 1980.
Specification for structural steel joints using ASTM A325 or A490 bolts, American Institute of Steel
Construction (AISC), Chicago, November 13, 1985. (Note: This specification is now avail... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 487 |
b7797461-9db6-4d69-bbbb-9b92277c7ce7 | Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C018 Final Proof page 442 26.7.2007 1:55pm Compositor Name: VAmoudavally | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 488 |
4147ac94-1850-4756-81bc-b62b4a943a6e | 19Design of Joints Loaded in Shear
19.1 AN OVERVIEW
Eighteen chapters ago I described two kinds of bolted joints: those loaded in tension and
those loaded in shear. With the exception of Chapter 12, the discussion since then has beenfocused on tension joints because they’re more common, their behavior is more complex, ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 489 |
7b844b37-9f23-4043-a173-a5ba0a5c20a5 | There are many different types of shear joint, but most can be defined as either a lap joint
or a butt joint, as shown in Figure 19.1. Historically, joints of either type were furtherclassified as ‘‘friction type’’ or ‘‘bearing type.’’ The structural steel industry has now aban-doned the friction and bearing classifica... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 489 |
ceac0d56-f637-47e3-bdd7-ab2bf1172b4a | that shear joints are more forgiving of assembly errors or preload scatter; they can operate
successfully under a much wider range of clamping force than can many tension joints. One ofthe main reasons for this is that shear loads don’t change bolt tension or clamping force theway tension loads do.
One new problem we d... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 489 |
7a086f1c-8066-4cb5-82ca-c3aadaecc753 | We’re going to start our study of shear joint design with our old friends, the VDI
equations. We’ll see what they have to teach us about shear joints, and will find that it’s
useful but not enough. So we’ll go on to look at the way the bolts and joint members seeand resist shear loads. All of this will be pertinent for... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 489 |
fe70b72e-178e-400f-8723-74056b2ff4d7 | Kulak et al. [7]. This complete text is now available, free, on the Research Council onStructural Connections (RCSC) Web site. Structural steel designers should rely on this textand on the bolt specs also written by the RCSC [8,13] rather than on my text. The bolt spec isalso available on the RCSC and AISC Web sites. I... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 489 |
b2763bad-d973-4bd6-8f1e-53f80c56dea3 | 19.2 THE VDI PROCEDURE APPLIED TO SHEAR JOINTS
Let’s return, for a final time, to the VDI joint design equations first encountered in Chapter
18 [11]. These raise two important issues we must address when designing any joint: theminimum clamping force we can expect to see in the joint and the maximum tension the bolts
... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 490 |
fb5f5957-80cf-4799-942d-51b4d9e73e5b | MaxFJ¼maximum anticipated bolt tension created during assembly; equals the clamping
force that bolt applies to the joint before the joint is put in service (lb, N)
MinFJ¼minimum anticipated bolt tension and clamping force created during assembly,
before the joint is put in service (lb, N)
FPrqd ¼minimum preload (and pe... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 490 |
4079415d-fda5-4bcf-bc9a-d687fd8e8a8b | lower splice plates.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C019 Final Proof page 444 26.7.2007 1:27pm Compositor Name: VAmoudavally
444 Introduction to the Design and Behavior of Bolted Joints | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 490 |
43e4b594-dc38-479f-9aed-5a8464642727 | FKn¼DFB=Lxwhere DFB¼the change in tension created in the bolts by the external load
This is the load factor we used when discussing tension joints in general
DFJ¼the change in clamping force (or bolt tension) created by an external tensile load
on the joint (lb, N)
Let’s look at each of these terms and see how they app... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 491 |
ec0588ec-51c2-4159-a3e3-6be2d843c641 | tension joint, but the effects are usually smaller, with the exception of embedment. Let’s lookat each effect as it applies to a shear joint.
Embedment : We can expect to see a typical embedment loss, perhaps 5%–10%.
Elastic interactions : Bibel tells us that the average elastic interaction loss in an ungasketed,
metal... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 491 |
ae220855-1e1b-4bec-9e99-301ca2b59f9e | assembly. I would expect the loss to be negligible, however, certainly nothing like the majorloss created by a gasket.
Thermal : In most of the (few) structural steel joints I’ve studied the bolts and joint
members have both been made of steel, presumably with similar coefficients of expansion.Unlike, say, a pressure v... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 491 |
7a14ad49-96a0-491d-b0f2-df66b7ae5487 | not uncommon. All of which suggests that differential expansion can be ignored in structuralsteel joints.
Airframe structures, on the other hand, often involve several materials, including
aluminum joint members and bolts of ferrous metals or exotic alloys. Temperature changes,however, are still modest. Grip lengths, f... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 491 |
21b74b4a-ba39-470c-b849-567db104216b | torque wrench is used on unlubricated bolts, for example, scatter might be +30%. Following
VDI’s lead, this would create an aAof (1þ0.3) =(l/C00.3) or 1.86. There are some factors that
make tool scatter different when we’re dealing with a shear joint, however. First of all, preloadcontrol is less important in most shea... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 491 |
d8154f87-ae4e-43a0-86a0-a09676a1f0c5 | structural steel work, at least, the bolts are often tightened well past yield, on purpose, and this
reduces scatter to +5% or so [1] and an aAof only 1.11. (VDI says that yield control will result
in an aA¼1.0, as you’ll see in Table 18.1, but I think that that’s overoptimistic.)
FPrqd: This is the force required to g... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 492 |
319fb51c-1bba-42ab-892b-4d8ddc05c4e0 | Do we now have what we need to design a shear joint? Hardly. The VDI equations allow
us to define the bolts required in a joint. This information helps us size the joint members andpick joint materials, but it isn’t sufficient to configure a joint. Most configurations will bebased on past experience or custom in a part... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 492 |
ed2d9657-5f1d-498d-abcb-51c262b3f170 | As Equations 19.1 and 19.2 show us, furthermore, we can’t even define the bolts until
we determine F
Prqd. Just as the leakage properties of a gasket determined FPrqdand there-
fore dominated the design in pressure vessel applications, so does something other than the boltdominate the design of a shear joint. We’ll tak... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 492 |
accc1cfd-31f1-4949-9c87-8b58af194952 | 19.3 HOW SHEAR JOINTS RESIST SHEAR LOADS
19.3.1 I NGENERAL
Shear joints resist applied loads in two ways. First, the interface clamping force generated by
the bolts creates friction forces which resist joint slip. Second, the bolts act as shear pins toprevent slip. Because of this, structural steel joints used to be di... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 492 |
78f8bc42-f4b5-44a1-997e-ebb72025e2e2 | their concern would apply to shear joints in other industries as well. At the risk of some
redundancy, here’s what they say.
19.3.2 C ONCEPT OF SLIP-CRITICAL JOINTS
Why are friction-type and bearing-type joints no longer considered valid models for structuralsteel joints, and what has replaced them?
Steel erectors must... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 492 |
cb590295-8e3b-44dc-bc1f-a7b2117f6df6 | joints are almost nonexistent.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C019 Final Proof page 446 26.7.2007 1:27pm Compositor Name: VAmoudavally
446 Introduction to the Design and Behavior of Bolted Joints | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 492 |
d6008117-53e8-4eff-b71b-f02169b787b7 | Every joint loaded in shear, furthermore, derives some of its initial strength from friction
between the joint members, even if the bolts were only snugged. Furthermore, every joint
under unidirectional axial shear loads fails by first slipping into bearing. Final failure of
such a joint is by shear of bolts and joint ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 493 |
78670b02-030c-42a3-a521-596126b3fc2e | As a result of all this, structural steel designers currently use the shear and bearing
strengths of bolt and joint members, rather than the friction forces, to estimate the ultimate
strength of all joints. They design for friction-dependent, no-slip behavior only in applications
which the engineer of record considers ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 493 |
248efa38-ff88-4122-a5f6-9f9dba48920c | Joints subjected to significant load reversals are also considered slip-critical, as are some
joints under fatigue loading. Again, it’s up to the engineer of record to specify which joints are
slip-critical, and should, as a result, be heavily preloaded. (Structural joints loaded in tension
are also heavily preloaded, ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 493 |
027956e4-62f0-47e1-9a0c-bcc60fd9ba94 | The concept of slip-critical joints was first codified in the November 13, 1985 version of
the AISC Specification for Structural Steel Joints Using A325 and A490 Bolts. This was one
of several significant differences between the 1985 edition of this specification and earlier
editions. After completing the 1985 specific... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 493 |
b121c245-da38-467a-914b-64487d9f0742 | until the bolts are brought into bearing. Next (3), there’s additional elastic deformation of the parts. This
is followed (4) by plastic yielding of bolts and joint members. Finally (5), something breaks.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C019 Final Proof page 447 26.7.2007 1:27pm Co... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 493 |
48f8db32-afd7-4f1b-afdd-f3e0e403cb09 | optional, alternate load and resistance factor design specification—again for A325 and A490
bolts. This so-called LRFD specification was approved for publication on June 8, 1988.People involved in structural steel work should obtain and study these two documents.They are significant departures from previous editions of... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 494 |
bea2fa1f-2211-4892-a188-1407f277d7e7 | version of Fisher and Struik [1].
Although the definition of slip-critical comes from the structural steel industry, the
concept is valid for most if not all shear joints. If any amount of slip will place the structureat risk, the designer must specify enough bolting to create sufficient friction to prevent slip. Ifsom... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 494 |
cf12351c-f9af-46ea-a23a-d4a6c55c5e7a | insertion tool of some sort before the nuts are tightened. Slip is prevented by zero bolt-to-hole
clearance. It’s difficult to create a known amount of interface clamping force under theseconditions, however, as illustrated in Figures 6.6 through 6.8, the joints must be designed soto resist applied loads in bearing. In... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 494 |
eb4169f4-d67c-45de-b142-42f794e3ddc7 | When we apply the VDI equations to shear joints we see that F
Prqd, the clamping force
required to prevent joint failure, can be a key issue. In order to quantify FPrqdwe need to
relate bolt tension to joint strength. The relationship will depend, obviously, on whether we’redesigning for strength-through-friction or st... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 494 |
5654f155-2a36-4811-bee0-0c97d233327e | s) and we’ll use the same
terminology.
The slip resistance is also a function of the number of slip surfaces ( M) involved in the
joint (see Figure 19.3). Three surfaces produce three times as much slip resistance as one
FIGURE 19.3 Shear joints having one and three slip surfaces.Bickford/Introduction to the Design and... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 494 |
b2454354-6b13-4c01-a2be-5d7d4b315ab3 | surface, and so on. The equation for slip resistance, therefore, is (see p. 71 in Ref. [1] or p. 75
in Ref. [7])
RS¼mSFPNM (19:3)
where
RS¼slip resistance of the joint (lb, N)
mS¼slip coefficient of the joint
FP¼preload per bolt (lb, N)
N¼number of bolts holding the joint together
M¼number of slip surfaces (see Figure ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 495 |
f219ee5f-5288-42ed-9f6e-441a494fe36b | in service. By definition FPrqdis the minimum bolt load required for a successful joint, which,
in this case means to prevent slip.
19.4.2 A LLOWABLE STRESS PROCEDURE
We can use Equations 19.1 through 19.3 to design a friction-type shear joint. We’ll look at anexample in a minute. But first: I said in the introduction ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 495 |
27275011-2eb9-4344-8a43-295fc6ff8638 | L
Xmax¼FsAbNM (19:4)
where
LXmax¼the maximum load which can be placed on the joint (lb, N)
Ab¼nominal body area of a bolt (in.2,m m2)
N¼number of bolts on one side of the joint
M¼number of slip planes
Fs¼allowable slip load per unit of bolt area (psi, MPa)
A table of allowed values of Fsis given in the reference. These... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 495 |
7f2dea8e-90de-4344-bb61-7d4262d884d2 | This equation does not include any reference to bolt preload, which might seem to be a
strange omission. But it’s only one of many provisions in the bolt specification of that document.In Table 4 of that document we’ll find specifications for the minimum tensions which must becreated in bolts of various sizes during as... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 495 |
4f2d3b32-cdee-4037-9b2f-c3a7d6729c24 | 19.4.3 O THERFACTORS TO CONSIDER
Equations 19.1 through 19.3 seem to define everything required to prevent the failure of ageneral-purpose, friction-type joint. But, as usual, there some other factors to be considered—including some substantial uncertainties.Bickford/Introduction to the Design and Behavior of Bolted Jo... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 495 |
778d4125-256e-4e9b-a79c-7db36f8f3571 | One factor is the strength of the joint member itself. It’s certainly possible to design a joint
in which the friction forces will exceed the tensile strength of the joint. That’s also easy to
avoid. Cyclic loads on a friction joint, however, can cause it to suffer a fatigue failure through
the gross cross section as i... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 496 |
59958b07-8f86-4b96-b496-d9e6e3056926 | In critical situations we may have to build, instrument, and test a prototype or model. Finite-
element analysis is also becoming more popular as a way to do this, but the FEA model
should be confirmed by physical tests whenever possible. As far as structural steel is con-
cerned, the cited references deal with these u... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 496 |
f15b2e91-8828-4c8c-8be8-f74858edebd8 | expect to see when we tighten a group of as-received bolts with a given torque will probably
be duplicated by a +30% variation in the slip resistance in a group of joints clamped together
by a given amount of preload. To my knowledge, only the structural steel industry has
published slip coefficient data. Let’s take a ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 496 |
5df45fc3-03c9-4ae6-aa5c-d0e002d6b829 | to allow the use of any coating which has been tested by procedures specified in Ref. [8], and
which has been so certified.
Note that the treatment of the faying surfaces and coating, and not just the type of
coating, affects the slip coefficient of the joint. For example, a hot-dip galvanized coating hasLX LX
N G
FIGU... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 496 |
532e0bfe-40d9-4797-a490-732d7633db2b | a friction coefficient of 0.18 (average). If that same coating is wire-brushed or grit-blasted,
however, the average coefficient becomes 0.4 (Ref. [7], p. 212).
Note, too, that generic classifications for coatings are not possible. The actual slip
coefficient of an inorganic, zinc-rich paint, for example, will vary fro... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 497 |
c448dd99-0f63-46ab-a070-5f05cf724ae5 | If a coating is required for corrosion protection, it should be one that has been thoroughly
tested. The four listed below, for example, have at one time or other been tested by the Research
Council on Structural Connections. Less expensive vinyl washes and paints are a recent addition
to the list (Ref. [7], p. 206).
1... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 497 |
b62c58a5-7935-4a80-8cdb-2492cfda26a5 | The slip coefficients given above are average figures. In critical situations it’s going to be
necessary to use minimum figures or (as is the codified practice in structural steel, allowablestress procedures) provide enough safety factor in the bolting requirements to cover suchcontingencies. Several tables in Chapter ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 497 |
4158c9c1-8f2b-4c7b-b1f8-cefd0df782c4 | and the standard deviation. Since the text deals exclusively with structural steel joints, the
treatments and coatings are limited to those found in or proposed for that industry.As mentioned above, coatings include hot-dip galvanizing, zinc-rich paint, vinyl coatings,and metallized surfaces which have been sprayed wit... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 497 |
9628f300-1334-46e7-8f10-e596a5640990 | Although most of this data won’t apply directly to joints in other industries, a sampling
may be of interest. You’ll find these in Table 19.1. Note that a standard deviation equal to10% of the average slip coefficient is not hard to find. This would suggest a three sigmadeviation of +30%, confirming my statements above... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 497 |
fc2792dd-1ca2-4e07-9c9e-70d569ab8283 | 1
41
2Lx = 5000 lbs Lx
(A)
(B)1
413
8
3
8
FIGURE 19.5 The joint shown here is used as a design example in the text. Load LXis also an axial shear
load because its line of action passes through the centroid of the joint. Note there will be no tendency for
the bolt group to rotate under such a load. The joint and splice ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 498 |
bafcce6e-912e-4895-879b-a0f43e7835bb | Sandblasted Vinyl wash 0.3–0.5 0.27 0.01
Sandblasted Vinyl wash; exposed
2 months0.3–0.5 0.27 0.05
Acid pickling Bath Hot-dip galvanized Not given 0.21 0.08
Acid pickling Bath Hot-dip galvanized 2.4–5.0 0.23 0.023
Source : All data taken from Kulak, G.L., Fisher J.W., and Struik, J.H.A. in Guide to Design
Criteria for ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 498 |
5055ec8f-8889-4f43-91bc-281a42f37e53 | Cross-sectional areas of the bolt:
Body¼AB¼pD2=4¼0.110 in.2
Tensile stress area of threads ¼As¼0.0836 in.2(see Appendix E)
Yield strength of bolt material ¼sy¼92 ksi (see Table 5.1)
Shear strength of bolt material ¼ss¼79 ksi (see Table 5.2)
Joint material: A36
Number of slip surfaces (or shear planes) ¼M¼2
Average tens... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 499 |
65e481cd-b4a3-478b-81c5-fc42d980489e | Then we’ll return to the VDI equations to see what information they can add. So first, fromEquation 19.3, recognizing that the F
Pin this equation is our first cut at the VDI FPrqd:
Rs¼mSFPrqdNM
The frictional forces must be large enough to resist the 5,000 lbs load, so Rs¼5,000. The
average slip coefficient for clean ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 499 |
4c6b6242-ea90-4427-8995-edcffac892ab | to use 1.86, but that would mean a Max FJgreater than the yield strength of the bolts, and it
would be impossible to develop that much preload in these3=4in. A325 bolts. If we accept
the VDI equations, therefore, we’d have to redesign the joint to use larger or more bolts.Or we could specify joint surface treatment giv... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 499 |
f1985d92-fefc-4f3c-b03c-ed25078e930f | Now, from Equation 19.2
7,691¼1.11 Min FJ
MinFJ¼6,929 lbs
and, from Equation 19.1
6,929¼1.3FPrqd
FPrqd¼5,330 lbs
This value of FPrqdis greater than the FPrqddetermined earlier from Equation 19.3. Which is
correct? The modified VDI Equations 19.1 and 19.2 take into account such factors as tool
scatter and elastic intera... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 500 |
ebe454ec-3e33-41dc-baad-b19ec769e794 | Now
m
s¼0:33/C02(0:07)¼0:19
From Equation 19.3
FPrqd¼5,000
0:19(2)(2)¼6,579 lbs
Plugging this value into Equations 19.1 and 19.2 would again suggest a Max FJabove the
tensile capacity of the bolt. One way or another, the cold, hard, realistic approach of VDI will
force us to use larger or more numerous bolts, or higher... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 500 |
33d745c4-1fa9-46ac-9c3b-d129c45475d7 | A325s, and holes are standard (i.e., neither slotted nor oversize). So
LXmax¼17,000 (0:110)(2)(2)¼7,480 lbs
Since the anticipated load is only 5,000 lbs, our design is acceptable. Do we now use Equation19.3 to find the preload required to support this load? For this example we’d have to.
Normally we’d use Table 4 in Re... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 500 |
800164d2-c69e-41f7-a574-7f58a14d1f1a | experience. Although such factors as tool scatter and elastic interaction are invisible in the
design equations, they were always present in practice and are covered by implication inthe allowable load figures or in the specified procedures for the handling, installation, andtightening of the bolts. If you are designin... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 501 |
50714073-08bf-49fa-9148-f86b00e4c2d8 | 19.5 STRENGTH OF BEARING-TYPE JOINTS
Several factors determine the load-carrying capability of a bearing-type shear joint. Theseinclude:
.The shear strength of the bolts
.The tensile strength of the joint members (called plates in structural steel)
.The bearing stress created in the plates by the bolts
.The tearout str... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 501 |
e222a569-c4bc-4f21-8359-b0bd92214be6 | N¼number of bolts on one side of the joint
sS¼shear strength of the bolt material (psi, MPa)
These terms will become clearer when we look at an example in a minute. But first, some
general comments about shear loads on bolts. Equation 19.5 implies that every bolt will bearan equal share of the load in a shear joint, an... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 501 |
73aa564b-d008-40f5-bc4b-787483df996b | to the leading and trailing edges of the joint will see far more load than those nearer the center
of the bolt pattern. Unfortunately, not even the bolts in a given row will share the loadabsorbed by that row equally. The placement of the bolts in their holes, minor variations inhole and bolt diameter, and the way the ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 501 |
17e34ecc-5987-4781-b41c-173431ba81b7 | of the applied load passes through the centroid of the bolt group as it does in Figures 19.4 and
19.5. The safety factor must be increased still further if the applied load is eccentric. Just asprying significantly magnified the loads seen by some of the bolts in a tension joint, so doeseccentricity magnify them in a s... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 502 |
8cf80162-e052-4c82-8465-78e2e4eb11ec | where
s¼shear stress (psi, MPa)
F¼shearing force applied to that one bolt (lb, N)
Ablt¼total cross-sectional shear area of that one bolt (in.2,m m2)
If there are Nbolts on one side of the joint, then
F¼LX=N (19:7)
For example, in Figure 19.5 upper and lower splice plates hold two joint members together.There are two bo... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 502 |
3fb1f412-94c3-408a-a7f5-bf010af0b8ef | As¼tensile stress area of the threads (in., mm) (see Appendix F)
In Figure 19.5 two shear planes pass through each bolt, one plane through the body and onethrough the threads, so
A
blt¼1(AB)þ1(AS):These are3=8/C020 UN bolts, so AB¼0:110in:2andAs¼0:0836 in:2
Ablt¼0:110þ0:0836¼0:194in:2
We can now compute the stress with... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 502 |
db13545e-d5e9-4faf-af53-b471c97eb49f | The allowable shear stress for Grade A325 bolts used in structural steel applications is 21 ksi
(145 MPa) [8], so we’re probably OK. The allowable stress in other industries might be higher,closer perhaps to the 79 ksi shear strength of A325 bolt material (Table 5.2). In fact, as analternative we can compute the total ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 503 |
c9f83fc8-4214-4764-9061-be16dce964f8 | So the joint shown in Figure 19.5 should be able to support the 5,000 lbs load with a 6:1 safety
factor. But we still have several other factors to consider.
19.5.2 T ENSILE STRENGTH OF JOINTPLATES
We compute the tensile strength of the joint with respect to the net section which includes themost bolts. (All rows may n... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 503 |
928d0cba-8a75-4feb-9b3e-4da74c5b8e42 | 19.5.3 B EARING STRESS
The bearing stress the bolts create in the joint plates is found from
sB¼LX
NDL G(19:9)
where
sB¼bearing stress (psi, MPa)
LX¼load applied to joint (lb, N)
N¼number of bolts on one side of the joint
D¼nominal diameter of the bolts (in., mm)
LG¼grip length of the joint (in., mm)
The area in bearin... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 503 |
bf48ef2c-3411-4d22-9571-49cca51aa6d8 | if the bolts are A325 or A490. The exact amount allowed depends upon whether or not the
holes are slotted, upon the number of bolts, and upon the distance between the row of boltBickford/Introduction to the Design and Behavior of Bolted Joints 8176_C019 Final Proof page 457 26.7.2007 1:27pm Compositor Name: VAmoudavall... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 503 |
51d5ef78-38ba-4c25-8343-d517f3d9f491 | holes and the edge of the plate. If we accept 1.0 times the minimum ultimate strength of A36
we can accept a bearing stress of up to 58,000 psi, well below the amount computed above.
19.5.4 T EAROUT STRENGTH
To compute the tearout strength we must first compute the minimum plate area which would
have to be sheared. Thi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 504 |
4ea94e14-0b22-4d2c-8e91-aae03d996f29 | Leg¼distance from bolt hole to edge of plate (in., mm)3
4
3
8
FIGURE 19.6 We compute the bearing stresses created by the bolt on the joint plates using the cross-
hatched area shown here, which is equal to the nominal diameter of the bolt times the joint’s grip length.
In the joint shown in Figure 19.5, therefore, the ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 504 |
dd305bdd-cdfc-4df4-b57f-5c31c847a43a | In our example
Ash¼(2)(2)(0:375)(0:750)¼1:125in:2
And the tearout strength would be
RTO¼Ashss (19:11)
where
RTO¼tearout strength of joint (lb, N)
ss¼shear strength of plate material (psi, MPa)
In our example:
RTO¼(1:125)(48,000 )¼54,000 lbs
Note that computation of tearout strength becomes far more complicated if there... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 505 |
d1c31d8f-0a61-4aaf-9e16-a39a65d77b0b | applied load is only a sixth of the shear strength, joint failure will not occur.
We also estimated the bearing stress the bolts will create on the joint and found it to be
much less than that we can allow. So the design of our bearing-type joint is confirmed.
19.5.6 C LAMPING FORCE REQUIRED BY A BEARING -TYPEJOINT
OK ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 505 |
d4b96399-d7b2-42d8-87a1-8b1027223f8a | prevent joint failure, so that we could solve VDI Equations 19.1 and 19.2. What do Equations
19.5 through 19.11 tell us about FPrqd? They tell us that no specific FPrqdis required. The
bearing-type shear joint will theoretically resist shear loads even if all the bolts are dead loose.In practice, we’ll tighten them at ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 505 |
73383ca8-fe92-4c1d-af8e-df784f9b2030 | 19.6 ECCENTRICALLY LOADED SHEAR JOINTS
19.6.1 R OTATION ABOUT AN INSTANT CENTER
Axial shear load means that the centerline of the external load passes through the centroid of
the group of fasteners holding the shear joint together, as suggested in Figures 19.4 and 19.5.Bickford/Introduction to the Design and Behavior o... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 505 |
331094be-dee0-4ef7-b689-68aa8255073e | In many cases shear joints are subjected to external loads that don’t pass through the centroid
of the fastener group, as in Figure 19.8. Such joints are called eccentrically loaded shear joints.
The external load is applied to the bolts through some sort of leverage determined by the
geometry of the joint; so eccentri... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 506 |
28f81ee0-7be1-4726-b3ca-2105f2f9af14 | ing and involves eccentricity and safety factors that must be determined by experiment. Such
factors are listed in structural design handbooks, which also list precomputed solutions for a
number of standard joints (see also Refs. [7] and [9]).
For our purposes, it is sufficient to say that those bolts located farthest ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 506 |
fd72b02d-94d0-4c03-8dc4-da30c3f8727b | 19.6.2 R OTATION ABOUT THE CENTROID OF THE BOLTGROUP
Although the joint will actually attempt to rotate about an instant center, it is easier to
estimate the shear loads on the bolts if we assume that it tries to rotate about the centroid of
the bolt group. This historically earlier and simpler approach results in cons... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 507 |
699071fc-8c7e-422f-9b04-e8e50f7c3a21 | xn¼distance of bolt nfrom an arbitrarily located yaxis (in., mm)
111
34
222
C
2.52.25
33
4xy
FIGURE 19.10 This joint is used as an example in the text, to compute the location of the centroid (C) of
the bolt group. The bolts are1=4in. in diameter. The xandyaxes are arbitrarily located along the left and
bottom sides of... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 507 |
4e5bb033-a03a-434e-9607-7d51fa926019 | yn¼distance of bolt nfrom an arbitrarily located xaxis (in., mm)
X¼distance of the centroid from the yaxis (in., mm)
Y¼distance of the centroid from the xaxis (in., mm)
With reference to Figure 19.10, let’s assume that the nominal diameter of the bolts is1=4in. and
that we’ve arbitrarily located xandyaxes along the bot... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 508 |
aee20565-e567-4526-8ef1-f5f0b3643afa | Now, with reference to Figures 19.11 and 19.12 we’re going to estimate the shear load on an
eccentrically loaded fastener. Let’s assume that the joint shown is a bearing type. First, we
compute the primary shear load on each fastener.
PP¼LX=N (19:14)
where
PP¼the primary shear force on each bolt (lb, N)
LX¼the load app... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 508 |
98259c64-45c5-4f40-a274-a9e5d73c316b | LX = 15,000 lbs
Line of
actionCrd 2
2
22
8
FIGURE 19.11 The joint shown here is used as an example in the text to compute the effects of an
eccentric load on a shear joint. Note that the line of action of the applied force, LX, is 8 in. from a
parallel line passing through the centroid (C) of the bolt group.
LX
C
2,500... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 509 |