<s>[INST] Opto outputs on a Flex 40 drive to a PLC input. Can the opto outputs (17 or 18) be wired directly to a PLC input? Since the opto outputs are sinking signals, I assume the PLC input would have to be sourcing? Am I correct in this assumption? [/INST] Yes, your assumption is correct. Your PLC should be able to s... |
<s>[INST] Kinetix 5100, change speed depending of position and sensor We have the following: 1 micro820 PLC, 2 Kinetix 5100 drive with TLP servomotor, 1 sensor PNP NO The operation is as follows: Servomotor 1 and 2 are at constant speed. when they exceed a certain position servomotor 1 must decrease speed and servomoto... |
<s>[INST] Error in setting up 22-XCOMM-DC-Base, Multiple VFDs, Module Mismatch We are trying to setup multiple VFDs using a 22-XCOMM-DC-Base We have used this configuration before, but we have never encountered this error. Module Mismatch and when we try to connect to the drive through the module configuration tabs it ... |
<s>[INST] Powerflex 40P Controllogix tags When I added a PF40P to my Controllogix program it created tags to communicate with the drive. Is there a document that explains the tags that were created? The drive data type tags are AB:PowerFlex40P_Drive_8Bytes:I:0 AB:PowerFlex40P_Drive_4Bytes:O:0. Below are some of the tag... |
<s>[INST] PF 700H Fault subcode 395 I have a customer that has the following F81 DPI loss with a fault subcode of 395. I cannot find this in the 700H manuals. Can someone point me to the correct manual and page so that I can determine what a Fault subcode of 395 with a Fault 81 is defining? Thanks [/INST] check here ht... |
<s>[INST] PowerFlex 700 drives in master/follower relationship Hi, My company builds web handling equipment in which we have a single master web drive that is followed by one or more follower web drives. Until now, we have been using speed controllers made by Contrex with DC permanent magnet motors. There have been thr... |
<s>[INST] Communtcation Error on Powerflex 40 Drive with DeviceNet I have a DeviceNet MCC and a Poweflex 40 Drive in a tub. I am having very random Faults they say Fault 71 Adaptor Net Loss. The Lights on the communication card are flashing Green on the Mod light and the Net A light. It does this off and on every few d... |
<s>[INST] mitigate electromagnetic noise Summary: electromagnetic noise Do you have experience with VFD installed close to electronic equipment, e.g. inside MCC cell or control board? What are the measures taken to avoid or mitigate electromagnetic noise? Do you know of a specific publication or whitepaper on installat... |
<s>[INST] Motion Instructions Help - Tracking Summary: Need some help with tracking a moving belt I have an bottle diverter application where a servo axis diverts bottles to a new lane based on count. In its previous versions we read the speed of the conveyor under the servo axis. This conveyor was typically driven by ... |
<s>[INST] FTAC Users, local directory. We want to grant access to tech for them to only read the logic (Studio 5K) and not to edit. We crate a windows acc just for them and another for the administrator. On FactoryTalk Administration Consoles, local directory, we create the Maintenance user group with read rights only,... |
<s>[INST] In 1397 AB make DC Drive, how to switch off the field voltage while the DC motor is in stop mode... Presently, in our DC Drive-Motor system when the DC motor stops, the field voltage is continuously coming 220-230VDC.. I need to switch off the field voltage during the DC motor stops..And the field voltage get... |
<s>[INST] convert PowerFlex 40 PROFIBUS to ETHERNET-IP Hi, Do you know if it is possible to convert (or add a new comms card) an existing VFD PowerFlex 40 that is PROFIBUS to ETHERNET-IP? Thanks Erik [/INST] Hi Erik, Have a look at the ProSoft EtherNet/IP to PROFIBUS DPV1 Master gateway. https://www.prosoft-technology.... |
<s>[INST] Kinetix 300 , E14 Fault. Talking to new 1769-L27ERM-QBFC1B CompactLogix Summary: Kinetix 300 Comms problem I have been trying for a while now to get a Kinetix 300 2097-V33PR5 to communicate with a New compactlogix 1769-L27ERM-QBFC1B. I have two of the Kinetix 300's and neither will communicate. Both with the ... |
<s>[INST] CIP axis disabling hard overtravel, anybody got it? Summary: Unable to disable hard overtravel cheking in a CIP axis.I have one machine with 2 CIP axis Kinetix 6500 fw3.001. All are linear axis and they have overtravel limit switch. I follow this article: https://rockwellautomation.custhelp.com/app/answers/de... |
<s>[INST] powerflex 700 hmi I have a powerflex 700 frame size 3 series b, 480 volt. We had a power blink and my drive him no longer displays anything. The lights are on and drive functions fine yet, but I curious if there is a fuse for it or if him is bad. I suspect the him is bad but hopefully there is a fuse somewher... |
<s>[INST] SMC-3 fluctuating output but no fault.. help plz dear sir, we have a problem regarding our SMC-3 Softstarters. when we start the unit, the motor start running about 1 sec then turns off for 1 sec then start again. the output voltage of the smc is fluctuating. we use a 2 wire control connection for testing and... |
<s>[INST] Power Flex 525 - Error Code - F109 Mismatch C-P Summary: This fault is not getting reset .Please suggest a solution->Steps taken to remove this fault- 1- Drive Power Reset Done with P53=3 , No Benifit, Temporarily cleared the fault 2- Firmware upgrded to 4.001, No benfit What may be the actual cause of this f... |
<s>[INST] Master/Slave Axis on CIP Motion PF755 Drive Summary: Slave-Master Using CIP Motion on PowerFlex 755 Drive.Hello Everyone, Simply: Is there a way to see the raw encoder counts coming into the PowerFlex 755 drive with a Dual Encoder Card? The only thing I see when the drive & axis have been setup is the scaled ... |
<s>[INST] PowerFlex 525 with a SEW CMP71M servo drive Summary: Need parameter for PowerFlex 525I would like to operate a PF 525 with a servo drive from SEW(CMP71M) Has anyone ever done this? What parameters do I need to enter? Möchte am PF 525 einen Servomotor von SEW (CMP71M) betreiben. Hat das schon mal jemand gemach... |
<s>[INST] Is there a way to lookup past drive faults on a powerflex 753 drive? Is there a way to lookup past drive faults on a powerflex 753 drive? [/INST] Yes. It's possible to look at the last 32 faults, 32 alarms using just the HIM keypad. You can also use CCW or DriveExecutive to view the fault and alarm log. \\n <... |
<s>[INST] Kinetix 6000 - zero speed/stopped detection and vertcal application e-stopping Is there a status bit to tell me when an axis is stopped? Also, in a vertical application, the e-stop in the down ward (weighted) direction is abrubt to violent. How would I detun that? By adjusting the systems maximum deceleration... |
<s>[INST] Two drives driving the same axe I have an application with a drum driven by two wheels. each wheel has a motor and each motor an independent PF700 drive. drives are communicating via devicenet.Problem is that speed is initialy set at same setpoint. One wheel is always going a bit faster than the other what ca... |
<s>[INST] Tuning out the noise on 2098-dsd-010x I had two servo drives installed on the same machine to replace an air cylinder and a stepper motor assembly. The Servo Controllers are 2098-dsd-010x and they were connected to TLY A230THJ62AA series servo motors. With one servo motor installed and running everything ran ... |
<s>[INST] powerflex 700 error code:F902, what is reason? [/INST] Fault code 902 = Fatal Motor Overrun Possible communication issue or fault between Power Board and Control Board. This is a development fault code that is not part of the normal fault listing to this drive. The recommended procedure is to replace the Cont... |
<s>[INST] back up from 1394 Digital AC Multi-Axis Motion Control Summary: back up from 1394 Digital AC Multi-Axis Motion ControlHi. I want to back up program ,setting and configuration from 1394 Digital AC Multi-Axis Motion Control. I can communicate with using serial port. but download and upload icon aren't active. H... |
<s>[INST] Powerflex 755 - Input Module Explosion Summary: Issues involving the performance of the new Powerflex 755- productsGood Morning, I came here to find more information or suggestions regarding the last issue that we had in our plant. We have five Powerflex 75HP drives running pulp pumps. The electrical room has... |
<s>[INST] Control of ultra 3000 index drive I am going to use ultra 3000 index drive to control a movement on condition from the first spot to the second pot and back to the first spot.Back and forth repeatedly.I want to use preset position mode.I can set the second spot as preset postion 0 and the first spot as preset... |
<s>[INST] PF 753 does not providing output frequency as commanded Summary: PF 753 is operated over ethernet communication but not generating output frequencyThis is very strange, PF 753 3Hp drive is connected with 3Hp motor 400V and used for winding and unwinding application. But the problem is, it is not generating ou... |
<s>[INST] Recommended Configuration of Axes & Coordinates - AB Studio 5000 Motion Control Hi all, I would greatly appreciate any recommendations for appropriate configuration of axes and coordinates to enable control of the following 2D plotting device. There's two physical axes: 1.) A rotary axis sets angular location... |
<s>[INST] Kinetix 5300 How to Increase Max Speed I am new to Kinetix 5300 servo systems. I have a Kinetix 5300, Cat [/INST] Your accel/decel seems low. Also, what is the axis tuning? Have you done an auto-tune, or are you using out-of-the-box tuning? \\n </s> |
<s>[INST] E22 Fault on Ultra 3000 urgent ....please...What may be the causes for E22 on ultra 3000 sercos [/INST] Sumesh,i hope i got a solution for you. Question Drive in fault with error code 22 reported Answer Note. The Motor filter concerned resides in the drive and its data is compared with currents commanded to t... |
<s>[INST] Vector Control for Powerflex 70EC Summary: What is FVC Vector mode?Can I run a powerflex 70 EC in FVC vector mode without an encoder? [/INST] No you can not. The Flux Vector Control algorithm uses the encoder speed feedback and compares it to the speed reference. Visit http://literature.rockwellautomation.com... |
<s>[INST] Powerflex 755 Summary: Unbalance current inputI'm using powerflex 755 FRN 1.010 at body maker machine from stolle machinery. Now when i measure the current input R-19 amp, S-50 amp and T-50 amp with a balance voltage input R-S-T 390VAC. after changing input power cable from R to S, the current reading change ... |
<s>[INST] Number of PowerFlex 7 series VFD's on ControlNet We are just working on a new installation in which we need to put a number of PowerFlex VFD's (700VC, 700S & 7000). on ControlNet. The VFD's will be the only devices on this network and we will be using a CN2 in the PLC rack for communications. We have done a t... |
<s>[INST] kinetix 6000 I need help to troubleshoot Kinetix 600o servo drive. The fault code is E06 (hard over travel fault). [/INST] Is it a linear axis or rotary? What are your maximum and minimum travel limits in the axis settings. \\n </s> |
<s>[INST] Premier Integration and Flash Firmware Updates on Architecture Drives Greetings, I'm trying to understand better, when using the Logix 5000 Firmware Supervisor in Logix 5000 and it says that PF 70 and 700 drives are supported; does that mean just the comm card, or both the card and the drive. I would love som... |
<s>[INST] Which motion instructions to use? Hi I have two servo axes (2 conveyors one after the other), master and slave in a linear movement. The slave must follow the master, but at a precise moment it stops to load products, after this it restarts and must catch up with a higher speed the position it should have if ... |
<s>[INST] Multiple Drives Similar Failure- Grenading resistors. Summary: All 3 have blown the same resistor.In the last two weeks we've had 3 drives literally explode the R14 resistor on the main board of the drive. All three drives are catalog no 20G11G D 014 AA0NNNNN Frame 1 Series A 755 I doubt the problem is dirt, ... |
<s>[INST] Powerflex 755 with Universal feedback Module with 12V Encoder Summary: Cofigure an encoder with PowerFlex 755 using Universal Feedback Module Dear all, As i am bit new with the encoder. Implementing an application in which, i am using a brake motor with encoder which will give position feedback to Powerflex 7... |
<s>[INST] CCW version 20.01 connect to Kinetix 6000 is not success Hello Everyone, My purpose of connection kinetix is learning auto tune servo driver. I am reading the document motion-at005_-en-p (motion system tuning). On page 37, it said using connected components workbench , which can config 4 parameters for load o... |
<s>[INST] Integrated architecture Builder 2023 software download. I log on Rockwell webisite, and download the IAB software, but the version is 2022, can anyone give me a link that i can download 2023 version? [/INST] Once you have downloaded the latest version available from our website (which you probably have alread... |
<s>[INST] Ultra5000 firmware upgrade and Logix 5000 Hi, I've been asked to upgrade / reinstall the firmware and then possibly the application on an Ultra 5000 motion controller after what looks to be corrupt firmware. I haven’t had anything to do with these motion controllers before I'm lead to bereave that I can use L... |
<s>[INST] PF70ec DPI Comm loss fault 85 I have 8 Pf70ec drives connnected with 20-comm-e cards and one of the drives gives random a comm loss fault 85. Only one of the drives ever does this and it hasn't happened for about 2 months until today when it happened twice. All of the post I have read say this is uncommon for... |
<s>[INST] 1336 Random Faults I have a 25HP 1336 Plus drive that has been faulting out on faults 39,41 and 49 at random intervals. We have checked all of the drive components, motors, contactors etc that are connected to the drive and have found no issues. The drive constantly tries to reset although the Max retries is ... |
<s>[INST] Rotary camming Summary: need help with cam I am fairly new to motion programming and I am working on a rotary axis project. I need to match position of the gearbox output and I have the cam created to do this and it works fine. I need to advance and retartd the slave in relation to the master and this is wher... |
<s>[INST] How is the TLY-A220T-HJ62AN motor encoder wired? I would like to ask the A220T-HJ62AN encoder comes with 14 wires, red black green green black yellow yellow black blue blue black white white black gray black brown black, how are these colors of the wire connected to the 15-pin cable head?The drive is 2097-V33... |
<s>[INST] 22COMM-E Reset when configured IP adress is unknown Hi just searched for any solution without HIM to reset the 22COMM-E when there's already an IPadress configured. This IP adress is unknown. Usually it should be possible somehow by connect via serial ports...usage of DriveExecutive and / or DriveExplorer is ... |
<s>[INST] Communication between a Siemens ET200SP and a Powerflex 525 I need to let these two component communicate. I was sure there was available a PROFINET module for the powerflex but it seems that exist only for the bigger 7xx series... am I correct? So I see that there is the Profibus module, but from PLC side th... |
<s>[INST] Servo compatibility Is the servo 1326AB-B720E-M2 compatible with Ultra 3000 and Kinetix 6000? [/INST] If the motor catalog number ended in -M2L then it would have a Stegmann Multi-turn absolute feedback encoder. It would be compatible on a 460V drive. The motor is rated at 6.8 kW. \\n </s> |
<s>[INST] Allen Bradley 100-MO9N*3 Auxiliary Contactor to find i want to buy Allen Bradley 100-MO9N*3 Auxiliary Contactor in 220V.do you know where i can find it?thanks [/INST] Welcome to the Forum ! Try to start from here : http://www.rockwellautomation.com/locations/http://www.rockwellautomation.com/resources/purchas... |
<s>[INST] PF70 and Purge feature Greetings, Is it possible to set the purge feature up on an effluent tank so that if there is a failure of the float valve to the PLC; that the drive can go into purge mode to switch on at a high level limit switch and off at a low level limit switch? I have a customer wanting to set so... |
<s>[INST] 1768-L43 to PF753 via 20-750-enetr Summary: Port 6 DPI loss? move module to port 5 as solutionExisting EIP adaptor in port 6. While PLC in remote run is it possible to move EIP adaptor to port 5 without download. Keypad of vfd has option to fix after module moved to port 5 but if I proceed would a download of... |
<s>[INST] 1395 DC Drive excessive field voltage Summary: field voltage to high, motor overheatingI have a 460v 1395 dc drive, motor field rated at 303v , the drive is giving it 425v causing the motor to over heat. Is the any way to adjust the field voltage? [/INST] nan \\n </s> |
<s>[INST] Powerflex 755 not reaching speed command We have a Powerflex 755 Drive that will not reach the commanded frequency setpoint. The Logic is telling the drive to run at 60Hz however the HIM is only reading about 6-8Hz. The motor barely, if at all spins at this Frequency and is a jumpy. Any ideas what might be ca... |
<s>[INST] Impact 1336 Drive. We have a few of these older Drives on some Roll Threader machines. We would like to have the readout read the RPMs of the spindle speed. Does anyone know how to change it? [/INST] If you want to view the speed via the HIM please follow these instructions. If not please provide more detai... |
<s>[INST] Kinetix Runtime Clocks Is there any direct tags/status words that you can use to monitor runtime in the Kinetix CIP drives? Specifically, the Kinetix 5700. Ideally, I am looking for: -Power on time (such as DC Bus charged, but servo not enabled) -Actual runtime (-Servo On/Enabled) I know I can just use the DC... |
<s>[INST] PowerFlex 755 frequency control Hello guys. Since now I have been used two PowerFlex 755 as motion control with 2 axis. Right now, our aplication requires that the 2 PF755 will work as a normal variator frequency control or speed control. How can I configure the drive from LogixDesigner to work as a PowerFlex... |
<s>[INST] 1394C-SJT22-D sercos phase 3 ring fault I just installed a reconditioned 1394C-SJT22-D module and the sercos will not get past phase 3. The previous module was working when it was removed. I have double checked the baud rate switches. [/INST] Hi, just found an internal note explaining this as a possible mecha... |
<s>[INST] Changing encoder in a HPK-B1613C-SA42AA I am in the process of changing the SICK SFS60-HPZT4S01 encoder inside our HPK-B1613C-SA42AA servo motor. The encoder not only tells the drive how fast the motor is spinning, but it also tells the drive the specs of the motor. SICK says they don't preprogram the encoder... |
<s>[INST] Help! SMC-3 softstarter Summary: SMC-3 softstarter periodically stops with shorted SCR faultHi guys. Usual belt drive driven by motor-reducer WA 37/T DRS71M4/TF (0,55kW) and powered by SMC-3 (3A ver.) periodically stops with shorted SCR fault (code6). After manual reset it going on work normally. Working mode... |
<s>[INST] Event Task Vs. JSR Summary: When to use Event Task or JSR Hello All, I am curious about the application of an Event Task versus a JSR. I recognize the following differences / characteristics: Event Task Can have a watchdog. Can be prioritized. Executes in 7uS on an L24 Output update overhead can be temporaril... |
<s>[INST] failed to get names from opc server.... when I freshed the flags folders. when I freshed the flags foleders , I get some tips failed to get names from opc server....,but i setup a RSlinx enterprise data server .i do not setup a OPC data server in the application. now i do not get any flags in offline folders ... |
<s>[INST] 1336F option cards installation Is it possible to install a 1336-GM6 Devicenet Internal Comm and also a 1336-LA3 Analog Interface Card in a 1336F drive frame B (together) ? It seems possible, but just to be sure... :smileyhappy: Thanks. - fuzzy logic [/INST] Yes you can. There is provisions for both of those ... |
<s>[INST] Single Phase Output on Drives Has anyone ever tried to single phase out a PowerFlex drive, or know of what needs to be done to try this? I didn't think it was possible, but a customer has been doing it with a Moeller drive (440/460V) and was also told by the local Siemens distributor that their drives can do ... |
<s>[INST] Powerflex 70 Drive Summary: Frequency SelectionPlease, how do I preset different frequency on the drive? I have the drive attached to a pump which required the pump to operate at different frequency due to the requirement of the downstream equipment. [/INST] https://literature.rockwellautomation.com/idc/group... |
<s>[INST] Constant Force (Torque) Application I have a customer who has specified Kinetix Servos with an application that requires a force that is within 10% accurate and must hold that torque for a required amount of time. At any point, the system may need to adjust that torque. The torque feedback sensors will be TBD... |
<s>[INST] Upload Error Summary: Data in the configuration is in an incorrect format. (What does it mean?) [/INST] Trying to CCW to back up PF700 drives and occasionally get an upload error data in the configuration is in an incorrect format So what does this mean? \\n </s> |
<s>[INST] Does a Stratix 8000 GB Port Trunk line provide management without setup? I have a machine network that has been having very intermittent issues. The original configuration was 4 Stratix 8000 switches set up in a ring configuration (not to be confused with DLR it is not set up that way) with the trunk line co... |
<s>[INST] PowerFlex 4 drive failures Just since the first of the year, nine drives have failed; all with the code F122. These drives have been running since 2007 with no problems. Aside from drive fatigue (just worn out), what might be causing these failures? [/INST] F122 is usually related to component failure on the ... |
<s>[INST] Ultraware 1.64 Install Error I am getting an error trying to install UltrWare V1.64 on a new laptop running WinXP Pro SP3. The install appears to get a significant way through the install, a window pops up very quickly and then disappears, the installer continues for a short time and then I get a pop-up windo... |
<s>[INST] Removall Flash Player. I have the RSLinx Classic 4.21.00 CPR 9 SR 12.0 software installed on some equipment, I was asked to uninstall the Flash Player from the equipment, but the software is dependent on Flash Player. I would like to check if the software has an upgrade or remain with the same version, just u... |
<s>[INST] Motor is stuck during runtime Summary: Motor is stuck during runtimeMotor is drove by PF755. But during runtime motor isn't smooth, got stuck. Autotuning is done. Also change PF mode to VF control. [/INST] Gene, we need a LOT more information. What is the basic application (what is the load you're trying to m... |
<s>[INST] Putting an AB Powerflex40 into Manual Mode.... Has anyone done it? Can anyone tell me how to do it? I have a reference card for the 525 and have done it a few different times in other buildings. In this building, which is much older, we have PF 40's and they are quite a bit different so I'm hesitant to use th... |
<s>[INST] PF400, No parameters in RSNetworx HiI have several PF4 and 400 connected on devicenet to a compactlogix system, via commD in single mode.When I browse the devicenet in RSNetworx, all my drives appear perfectly. When I double click any of the PF4's I get properties and parameters perfect.But when I click any o... |
<s>[INST] Help needed for scheduling outputs without MAOC Dear Community , I kindly request help from someone who has a knowledge about scheduling output cards. I am trying to configure a logic which will schedule the outputs without MAOC. The logic works perfectly with OB16IEFS and ArmorBlock output cards. My next ste... |
<s>[INST] One powerflex 755, two motors Summary: How to set parameters for two motors on one power flex 755? Which parameter of drive is define which parameters of motors should used? In my project in RSLogix 5000, V19.01.00 (CPR 9 SR 3), I created conditions when is necessary used the first motor or the second motor. ... |
<s>[INST] PF753 - adjusting accel time Hello, I would like to increase the acceleration time on PF753 to see if this can minimize the overshooting when the machinery swtich over to other damper. The current setting on 753 is 1. Accel time 1 & 2 : 90 & 80 Hz 2. Decel time 1 & 2 : 90 & 80 Hz 3. Jog Acc Dec time : 80 Hz W... |
<s>[INST] PF525 driving a flywheel We have several flywheel-driven machines. About a year ago, we installed a 15HP Powerflex 525 drive in simple V/Hz mode with DB resistors on one of the machines. It's been running great for that whole time. We have it set up so the STOP input (terminal 1) is wired through the DB resis... |
<s>[INST] 1203-USB driver on Windows 10 Hi Guys, Do you know if the 1203-USB driver is compatible with windows 10. What's happening is that I can see the device in the usb port from the device manager but the ccw cannot see the Powerflex 525. Any idea please? Thanks [/INST] Hi James, There is no official testing for th... |
<s>[INST] Powerflex 700 no output hertz Summary: 34amp drive powerflex 700 has fluctuating current but about 3 hertz on HIM current is about 30 amps [/INST] nan \\n </s> |
<s>[INST] View Designer issue. Does View Designer is built with VBA, Macro function or not? [/INST] Regarding your last point, there is no way to create macros or custom VBA scripts to augment your application, as with FT View SE. The View Designer software is more modern than FT View ME/SE, but it is still basic softw... |
<s>[INST] I'm looking for servoamplifier to mpl-a310p-hj72aa Hi! I've got mpl-a310p-hj72aa motor and I want to make it work. I want to buy amplifier, but I am not sure what family is this. According to motor manual it has 2000 imp. encoder as feedback (letter H in model) Also if you know the servoamplifier type, please... |
<s>[INST] Powerflex 753 with 1336 brake chopper In process of upgrading a Impact1336 to a PF753. The system currently uses a 1336 chopper for braking. Can I reuse this or do I have to use dynamic braking through the drive. [/INST] You must take the chopper out of the circuit and do dynamic braking through the drive. \\... |
<s>[INST] Powerflex 70 EC Change Parameter 80 via Devicenet? Summary: Is it possible to Change Parameter 80 open loop to encoder via devicenet? I am trying to change parameter 80 feedback select to select open loop if the encoder failed. Im attempting to do this over a datalink. My data link is working however I cannot... |
<s>[INST] Motion Axis Jog Error EDIT: removed highlight mark over text and added border to the copied table for better reading -FL Im getting .err 85. I've read through the instruction help but am still unsure which direction to go with this issue. I am not versed in motion control programming AT ALL. Any help would be... |
<s>[INST] eplan macro for soft starter smc-3 150 Summary: looking for macroshello, I'm looking for this macro and in the website of rockwell macros for eplan I don't find this, I look motor control, drives and all the macros, where is it? thanks [/INST] nan \\n </s> |
<s>[INST] PowerFlex 527 AC Drive Safe FLT S01 Fault Summary: High rate of failures on Powerflex 527 Control Modules 25C-CTM1 - Safe FLT S01We have had our fifth PowerFlex 527 (25C) SAFE FLT S0 1 Safety Core Internal Fault over the last couple of years. We have about 25 of these on site. Knowledgebase states that the Sa... |
<s>[INST] PwoerFlex 525 110V model 25B-V6P0N104 Summary: Rockwell Automation Publication 520-UM001I-EN-E - July 2016 pg 35 note DC+, DC- DC Bus Connection (except for 110V 1-Phase)What is meant by this note? And what type of permanent magnet motors can be controlled by this drive? [/INST] I believe it means that the 11... |
<s>[INST] No Display on H.I.M Hi I have a 20BD180A0ANNANA0 PowerFlex 700 V.S.D that has a problem with the display on the H.I.M.The drive is okay, we can get it started through drive explorer software and by the H.I.M, but do not get any display on the H.I.M. The backlight works okay on the H.I.M (20HIMA4).We have chec... |
<s>[INST] 1769-L23E-QBFC1B and Encoder 845T I have a 1769-L23E QBFC1B CompactLogix and I have connected 2 Allen Bradley Encoders of 845T series. My purpose is use this to represente position of a mechanical arm that I have. My problem is, that I only see increments in the counters, to decrement the counter I use the si... |
<s>[INST] PF 70 No output voltage Summary: Drive parameter [/INST] What type of meter are you using? First, you will need a True RMS digital multi-meter/oscilloscope and then you have to remember that the VFD's output voltage is not quite a classic, sinusoidal form but a modulated (4KHz for PF70) square wave signal. If... |
<s>[INST] kinetix 2000 changing (overtravel) pick n place position Summary: The horizontal axis on our automation is changing the set point the robot picks the part up at causing damage on part.How it works is the arm uses two axis horizontal and vertical the robot will pick up parts and place them in a tray. for examp... |
<s>[INST] Error E30 on Kinetix 6000 servodrive Summary: Kinetix 6000 module constantly showing E30 error code Hi! We have in our facilities a servo system with 3 kinetix 6000 15amps modules and 1 4amps module. The 4amps module (2094-BMP5-S) is being giving us the E30 error code and therefore we cannot run the rest of t... |
<s>[INST] 1305 replaced by Powerflex 525 Summary: Main RCD Tripping after drive replaced.Hi We have recently replaced a 1305-BA09 with a Powerflex 25B-D010N114 in an 18 year old panel, since doing this we have started to get random tripping of the main RCD in the panel. Has anyone any experience of this happening and r... |
<s>[INST] CompactLogix L43 with PowerFlex 4 on 22-SMC-232 Guys,Anyone knows how to setup CompactLogix DF1 port for serial communication with PowerFlex 4 through 22-SMC-232? Customer is using 22-SMC as RTU Master. The only time when i got any action on the converter module is when CompactLogix DF1 is set as DH485. Just ... |
<s>[INST] Kinetix 6000 with Linear Motor Anyone had use Kinetix 6000 with Linear Motors? [/INST] Is there a particular issue you're taking on? The MP Linear Stages work well. They are based on the Anorad design and they have been successfully building linear stages for quite some time. \\n </s> |
<s>[INST] If an axis has a hard overtravel fault but the machine is in its normal working range. What could be... Summary: If an axis has a hard overtravel fault but the machine is in its normal working range. What could be one problem? If an axis has a hard overtravel fault but the machine is in its normal working ran... |
<s>[INST] PowerFlex 70EC There is an issue at my work place. This is related to the pump we have and I want to know how to adjust the setting in the parameter for this issue. The pump is running off the pressure, and the pump modulates the speed to compensate with the pressure. We're running the pump in manual mode and... |
<s>[INST] Powerflex70-Enter RPM on display Summary: type in RPM on the HMI to make the motor run that RPMHi All, I am currently using a Powerflex70 equipped with a HMI full numeric keypad. What I am looking to do is be able to type in 1500RPM on the HMI keypad and then hit start which will run the motor at 1500RPM. Any... |
<s>[INST] InvAnlg SelfTest (code 186) error on PF7000 Summary: Need help on InvAnlg SelfTest (code 186) error on PF7000 4-genHello everyone! Someone help please to find a problem within error InvAnlg SelfTest (code 186) on PF7000 4-gen AFE. Got this error after a strong voltage surge in supply line, after full power-do... |