text stringlengths 38 9.81k |
|---|
<s>[INST] Powerflex 753 frame 6 20F1 stuck in AB Logo Gents, when the PF powered up for the first time at site, the HIM shows/ initializing and stuck there. it is rev 14 drive.. any input or troubleshooting guide? STS led is blinking red.. when online using controlnet connection, it shows recoverable fault. nothing muc... |
<s>[INST] 1756-HSC card Configuration Don't seem to find anything in the configuration of this card using a encoder to change direction of counts? Have hooked it up counts up when turned counter clockwise. Would rather it counted up when turned clock wise. We switched the a and b channels going to the card and that see... |
<s>[INST] PowerFlex 525 7.001 Firmware Update Not Flashing I am trying to flash the firmware of a PowerFlex 525 from 5.001 to 7.001 without success. I am using ControlFlash 15.07 with Windows 11. I am able to see and pick the drive in ControlFlash, but it errors out at the end. The message I receive is ERROR: Update to... |
<s>[INST] PF40 Firmware upgrade Summary: Is it possible to Flash new firmware into a PF40I have some Older PF40's going into service that do not have the latest firmware in them and the RSLogix5000 does not recognize them. Can Th Drive Firmware be upgraded? [/INST] Hmmm, that seems strange, it should be recognized in a... |
<s>[INST] PF523 Output Phase Loss Summary: Parameter 557When P557=Disable, the motor is running OK, When P557=Enable, when give the command to the drive the motor can not run ,and the drive generate fault F21 output phase loss So strange!! Could someone give me some advice? Thanks [/INST] nan \\n </s> |
<s>[INST] Change nodes Maxpak III Summary: How to change nodes in a Reliance Maxpak III Hello, I have a CD drive Reliance Maxpak III, and I want to restore factory settings originates. As I can do from the keyboard? Thanks [/INST] Hope somebody will be able to help on that, I'm not, unforunately. In the meanwhile, I ma... |
<s>[INST] Ethernet Conections for PF70 drives Can anyone tell me how many ethernet conections a PF70 drive will take up using two datalinks talking to a ControlLogix? I need this to determine how many EN2T cards I will need in this system. Thanks. Eddie [/INST] Merlin402, a PF70 ethernet/ip card uses only one connectio... |
<s>[INST] PF 40 can't get reverse to work single phase feed (208) paramater is at 0 [/INST] timpl, just some more infos needed... may you post how do you connect the drive inputs?do you want to reverse from keypad, digital I/O, comms ?!P036, start source, which value ?A051 - A052 - A053 - A054 are different than defaul... |
<s>[INST] Power flex 527 ip address,Subnet mask & gate way getting default In power flex 527 the ip address and gateway are both same in our plant. (ex- IP address 192.168.2.84 ,subnet mask -255.255.255.0 & gateway 192.168.2.84 ). I set the ip address through dhcp . When after i connected to the network all the ipaddre... |
<s>[INST] Silent or Unattended Install of Multiversion Studio 5000. I'm trying to use Microsoft SCCM to manage and deploy Rockwell software has anyone gotten the multiversion of Studio 5000 to install all the available versions in the install file? If so, what was the command you used? I'm hoping this works: Setup.exe ... |
<s>[INST] Does PF40P suport -10V~10v? Hi, Use AB PF40P to replace Yaskawa F7 drives, User manual of PF40P said Analogue input suport +-10v, this means it supports -10V~10V? How to make it? [/INST] Hi there, In your manual, go to page 1-22, and have a look at the options for analog input. You will connect your analog si... |
<s>[INST] Powerflex 525 - Ethernet IP - Third Party PLC Hello All, I'm new to this forum, and have searched for documentation regarding the Powerflex 525 and the addressed / registers of the EDS File. I have used the 0001009600090500.eds file, downloadaded from the rockwell site. I use the embedded ethernet port and us... |
<s>[INST] Kinetix 6200 Driver Safety Fault FLT03 Summary: What is the means of FLT 03, without extend error code? How can we avoid this kind of issue? Does any detail information of this fault? What is the better solution to resolve this safety circuit faulKinetix 6200 Driver Safety Fault FLT03 What is the means of FLT... |
<s>[INST] Drive 1305 - BA09A Summary: Do not run from HIMStatus: Stopped, +0,00 Hz Parameters was reset to factory. Can't find in User manual how to run motor from HIM with no other control connectings like buttons, switches, potentiomemeters and outside DC source? If it possible? [/INST] Did you jump together terminal... |
<s>[INST] Kinetix 5500 using POINTIO digital input as home sensor Summary: using digit input as home sensorIs it possible to use a digital input acquired by a POINTIO as homing sensor for Kinetix 5500? (avoiding wiring the home sensor straight into the drive) [/INST] There's a couple of options. Jog the axis and execut... |
<s>[INST] Fault Kinetix 6500 Hello my friends. I have a problem and I hope you can help me. Why does a Servodrive remain in Stand by status? and it cannot be corrected, the only way is to turn off the entire machine (including PLC) and only then will the servo drive return to its Running working state. And it is not ju... |
<s>[INST] powerflex 400 heatsink overtemp fault Hi,We are getting a heatsink overtemp fault on our powerflex 400. The fans do NOT start turning when a start command is given. I replaced the fans and still no luck. I suspect there is some kind of power supply board that runs these fans. Does anybody know what part [/INS... |
<s>[INST] Powerflex 40 capacitor shelf life Summary: Cat [/INST] Ken, here a technote that may be interesting: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/18015 - fuzzy logic In order to enhance Forum's contributors reputation, please rate the replies you got and remember to close the thread clickin... |
<s>[INST] Powerflex 525 with 25-ENC-1 installed Hi, I have a PF525 FW 7.0.1 with enc card with a ifm rvp510 encoder. If tried using the CCW basic wizard with enc set to single chan, once I got to the direction test part of the wizard I get 0 encoder speed with the motor moving, and when I try quadrature I get faults ri... |
<s>[INST] Multi Turn High Resolution Encoder Power Supply Summary: Not sure how to determine the supply voltage for my motor encoderHi There, I am dealing with a Kinetix 300 drive connected to an MPL-B430P-MJ72AA motor, looking at the encoder connector setup, on publication 2097-IN001K-EN-P, page 11, at the bottom is a... |
<s>[INST] Kinetix5100 Micro LC50 Hi Everyone 1st time posting here. I have a Kineti5100, MicroLC50 and downloaded software provided by Rockwell, example code. Dynamic Position Move, using the C_RA_K5100_Index_CmdSts_V2.2 Everything works just fine except for one thing. After issuing a STO function and then resetting th... |
<s>[INST] 25-COMM-E2P Connectors I have several (18-20) 25-COMM-E2P, but they came with the PF523 Connectors and I am looking for the PF525 connectors. How do I get a hold of some PF525 connectors and are they easy to switch out? Thanks in advance for any help. [/INST] Welcome to Engage, Michael! Connectors are shipped... |
<s>[INST] drives software - hey guys, I am pretty new to the AB world. I have a solid understanding of drives but with DanFoss and Tele software was basic and straight forward. I am getting lost in the Rockwell world, no idea when or why you would use Linx. When you choose Observer over DriveExplorer or Executive or Li... |
<s>[INST] AB SMC-3 soft starter shows overload and need help in identifying any easy fixes I have a soft-starter SMC-3 and from today it throws overload error every time I power on and the motor shuts off in few seconds,I'm looking for any simple fixes that can get me started. I already did the reset press on the start... |
<s>[INST] Using MAJ instruction when a MAG is already active Hi everyone, I'm actually trying to torubleshoot a Tension control system created for an OEM and the way it actually works is gearing the axis with a virtual master and then after passing a defined speed they are enabling the tension control and beginning usi... |
<s>[INST] Questions regarding the MAPC master lock position and cam lock position Hi, I'm setting up a motion axis with MAPC motion instruction. We are programming a derrick crane's main boom hoist axis to maintain a constant horizontal movement speed. The virtual/master axis is the boom reach radius, and the physical/... |
<s>[INST] Powerflex 525 - Phase loss Hello , I want to ask if this setting “A557 phase loss detection” is parameter that can be used to detect phase loss on 3 phase motor . And if “phase loss treshold” A576 is set good if default is 25% for induction motor . My power supply is 400Volt AC as for Europe , i was wondering... |
<s>[INST] PowerFlex 700S doesn't spin motor Summary: PowerFlex 700S running, without alarms, but doesn't spin motor - Hi guys, -We have a PowerFlex 700S Phase II Frame 10 Cat: 20D385A0ENNBNGNE, where with the speed reference, and running, sometimes doesn't spin motor. We had checked parameters 125,126, (Torque Pos Limi... |
<s>[INST] ultra 3000 sercos DriveHardFault Summary: Have problem with drive hard faults on a ultra 3000 digital servo drivewe have this fault after we power down to clean machine, sometimes it will power back up with no issue. But most of the time it requires many power off then power on to correct the DriveHardFault. ... |
<s>[INST] Powerflex 70 -retreive parameters Summary: I would like to retreive the parameters of the drive Can you remove cover of powerflex 70 drive while on? I would like to upload the parameters. It has a mini-din round connector, but on the inside. Thanks George [/INST] Yes, you could remove the cover when the drive... |
<s>[INST] Upload Parameter from Kinetix 350 Hello every body. We have 5 kinetix 350 servo drive which have connected to 1769-L33ERM CPU in our machine . I want to back up program from PLC and Servo drive. If I upload program of PLC , are there parameters of servo drives in program of PLC? [/INST] Hello Akbar Kinetix 35... |
<s>[INST] Powerflex 753, Hi all, 1.is there any parameters to adjust in powerflex 753 to stop Fan for spinning backward before starting forward? 2. could spinning backward hurts powerflex 753? if it yes, how can fix this problem? Motor info: 50 HP, centrifugal Fan, 60 Hz, 460VAC AC drive info: 20F11ND077AA0NNNNN [/INST... |
<s>[INST] Kinextix 6000 upgrade to 2094-BMO1 s I have ordered the direct replacement for my old 2094-BMO1 drive and I was wondering if there would be any programming needed in order to use the S series drive? I know that the old one did not have the safety relay in it so I do not know if that is going to cause an issue... |
<s>[INST] Powerflex 525 vector mode explanation? Summary: What is velocity vector mode?We have recently learned that the PF525 drives in closed loop vector mode are not in flux vector control, they have what our local RA drives rep described as velocity vector control. He described it as glorified V/Hz mode with feedba... |
<s>[INST] Intermittent F12 HW overcurrent and F36 SW overcurrent faults I have a customer who installed a PF700 (20BD077A3AYNANC1) in place of a bulletin 1392 ac spindle drive. the original 1327- spindle motor remained, and the 1392 was removed.the machine after start up has run now for about 1 year. Intermittently the... |
<s>[INST] PM 3000 Modbus TCP Can anyone tell me how to communicate with modbus TCP on 1404-M405? Is it with the -ENT option, or is there another for modbus TCP? [/INST] PM3000 -ENT option only support Ethernet/IP protocol, there aren't other options for Modbus TCP (see screenshot)... :smileysad: In order to do this com... |
<s>[INST] FT Optix Databases. Is there a way to call and execute store procedures from Database within Optix? For instance, I would like to execute a stored procedure with a click of a button. [/INST] Great question. It's important to know that the default embedded database in Optix is SQLite. I'm not sure if stored pr... |
<s>[INST] Re-tune Some one know where I can get info about a detailed description of tuning procedures?I need to understand when I need to make a new tune to my system. Or if I need to adjust some values or gains.I have some problems with loose position, torque over limits and some noises. [/INST] Here following a list... |
<s>[INST] SMC-3 series b: compressor is pulsing i have a switch cabinet for a heat pump with two compressors, I want to test it with a smaller compressor, but the smc-3 is pulsing the compressor for ca 1 minute befor continuous operation. what can I do that the start is not pulsing? using a zh21ke-tfd-524 compressor wi... |
<s>[INST] Upgrade 1336 Plus II to PowerFlex 70 Summary: Looking for information for converting prameters from 1336 Plus II to PFlex70 I am Upgrading a 1336 Plus II to PowerFlex 70. The 1336 Plus II uses the 1336-GM1 Remote IO adapter and the PowerFlex will be using the 20-COMM-R. I have the user manuals for both drives... |
<s>[INST] Controlling a PowerFlex 755 with serial MODBUS over RS485? Summary: Controlling a PowerFlex 755 with serial MODBUS over RS485? Can I controll a PowerFlex 755 with serial MODBUS over RS485, using the built in DPI port? [/INST] You will most likely have to use the 20-COMM-M Modbus/TCP communication adapter opti... |
<s>[INST] PowerFlex DC Interposing Relay Summary: Recommendations for Interposing Relay on Frame C drive? Customer says tech support said an interposing replay for the main contactor on a Frame C drive would help with contactor faults. KB document 32187 indicates that we don't recommend an interposing relay for a 100C ... |
<s>[INST] kinetix 5500 duplicated IP adress fault Hi, i Have a kinetix 5500 drive and it stop and show a message duplicated IP address in the manual this fault is a major fault, i try to change or another IP address but the fault still happening, the servo drive is faulted any time when is active and when the control ... |
<s>[INST] Kinetix 5500 S47 (FBK Device Failure) Summary: Kinetix 5500 Feedback woodoo with MPL motor.Hello Guys! I have an interesting problem with a Kinetix 5500 drive. The machine built with 3pc 2198-H008-ERS drive and 3pc MPL-B220T-VJ72AA motor. The CPU is a CompatcLogix L30ERM. The problem is what I wrote in the ti... |
<s>[INST] How to download parameters of drives via device net? I have a 1769-L32E controller attached with a devicenet module (1769-SDN) which consist of 7 nos of POWERFLEX40P Drive . How can I download the parameters of the drive without connecting my laptop to the drives? Is there a way I can download it through via ... |
<s>[INST] 1756-HSC has to counter 0 & 1 can we wire same encoder to both? [/INST] Bruce40, I've seen many times one encoder connected to two different devices... normally is not a suggested connection due to to the noise that may flow between the two devices over the encoder wires (here really you have the same device.... |
<s>[INST] Powerflex 4 Parameter A102 Summary: Display D019 shows A102 parameter as 219E We had a problem with a motor driven by a PowerFlex 4 drive. On looking at the PF4, saw it was displaying 219E on D019. If I understand correctly, D109 shows the value of A102, which is the Testpoint. What is the Testpoint used for?... |
<s>[INST] Motion forum is now OPEN TO THE PUBLIC! Rockwell Automation is very happy to announce that access to the Drives and Motion forums are now open to the public. Now, you no longer need to have a support contract to converse with your peers on Drives and Motion related issues! A step long requested by you, our cu... |
<s>[INST] Powerflex 70 electrical noise I am having a problem with electrical noise from the output of a pf70 that is affecting a metal detector in a food production line. The noise is being picked up on the coil of the detector and has been confirmed with an O'scope, it is preventing the detector from doing it's job. ... |
<s>[INST] Powerflex 755 Speed Synch I have an application in which two motor speeds need to be synchronized under varying loads. One motor is a 30HP and the other is 10HP. The 30HP is the master and carries the bulk of the load. The 10HP should run at the same speed as the master to assist with load. Each motor has a 1... |
<s>[INST] 755 AC Drive Harmonic spectrum Hi everyone! Does anyone have the harmonic spectrum of the 755 AC Drive Harmonic? [/INST] If someone is asking about harmonics, they are probably looking at compliance. The harmonics can depend upon the design of the VFD, the VFD configuration parameters, the connected load, and... |
<s>[INST] Rockwell vulnerabilities Hello I've never used this form before and I'm not sure if this is the right place to ask this question but do we have some settings somewhere that we can pass along to customers so they can get automatic notification of when Rockwell knows of a security vulnerability? [/INST] Hello a... |
<s>[INST] Reading 1336 VFD over ethernet possible? This may be a dumb question but I see a 1336 VFD drive in my RSwho, but I can't right click on it and see a data monitor. I can use a browser to it's IP and see data there, speed, faults etc. If I wanted to use OPC or ABR to read the data from this drive over ethernet ... |
<s>[INST] FTVSE Client PC - Specify Directory Issue. I have an issue with Network Distributed Station. When trying to change directory from local to network on Client PC, i get an error like this (see picture below). The Client PC is a mobile panel from KeBa KeTop155 with an Embedded Windows version. There are other cl... |
<s>[INST] RSNetWorx ControlNet Software. I've observed that all the I/O IF16H and OF8H installed on 1 backplane rack lost their hart parameters. Upon download the back up program the control module properties shows the code 16#0304 wich indicate that the module is not configured to send scheduled data.To use the RSNetW... |
<s>[INST] Multi Motor application with Powerflex 755 In our standard application we normaly use a 45kW drive for 6 or 7 5.5kW Motors. Now we have a application with 18 1.8kW Motors (--> 32.4kW)We want to use also a 45kW Drive and standard 5% Output Line reactor (1321-3Rxx)Cable length per Motor is maximum 10 Meters. Yo... |
<s>[INST] powerflex 753 and 755 lock parameters can we lock parameters with this series of drives? [/INST] Welcome to Engage, aguirre! Try to read the following technote: QA18210 Hope this helps, fuzzy logic Please don't forget to LIKE and highlight the decisive answer: REPLY > Make Best Answer \\n </s> |
<s>[INST] how to select the powerflex drive when you get an application like 3ph, 600v, 2hp, what will be based on to choose powerflex 40 or powerflex 70(for example), why?sometimes, design engineer chose the powerflex40 not 70, however, I found 70 also is okay to handle the current, frequency, and torque, tons of thx ... |
<s>[INST] Virtual axis in the emulator Does anyone know if you can run a virtual axis in the logix 5000 emulator. Ican load the program but get and error.bit whenever I try and run it [/INST] You may find all what is supported in RSEmulate5000 at this link: http://literature.rockwellautomation.com/idc/groups/literature... |
<s>[INST] DriveExecutive requires Administrator rights Using DriveExecutive ver 5.01 to connect to a PowerFlex drive requires the user have administrator rights to the computer. Referring to Answer 54009http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54009This issue is over a year old. Has anyone found a... |
<s>[INST] Kinetix 6000 in mode torque control.... How do I configure kinetix6000 to work in mode torque control with MPL-B320P-M? Thanks [/INST] Under the Drive tab, you can select Torque Mode instead of Position Loop. I'm drawing a blank on the exact names, but it's under that selection box. Just be careful that you p... |
<s>[INST] Conversion from Beijer to FTView. I have to perform a conversion from E-Designer (Beijer) to FT View, it exist any tool that help with this conversion or is necessary do it from the beginning in FT View? [/INST] When recreating the application in FT View Studio, I find it helpful to take a screen capture of e... |
<s>[INST] seriesA and SeriesB Summary: is power-flex driver seriesA and seriesB work together? hello, my name is said and I have a trouble at the machine drivers, machine has allen-breadley power flex drivers(vector ) seriesA (old version)and we want to use this series A with together series B power flex drivers.PLC is... |
<s>[INST] Ultra 3000 non index Analog input position control HelloDoes anybody know or have an example how to control position on an Ultra3K with the analog input? I tried but I keep having E19 code, I have no problems if I control speed with the analog input, but on position is not working.Any help will be greatly app... |
<s>[INST] powerflex, 753,755 can you lock parameters? with this series of drives [/INST] Duplicated thread, see HERE for the one already answered: I'm closing this thread. fuzzy logic Please don't forget to LIKE and highlight the decisive answer: REPLY > Make Best Answer \\n </s> |
<s>[INST] Kinetix 5500 module fault Hello Everyone, Now the system have 4 servos ( Kinetix 5500), all of them are running good, but sometimes one of them has the module fault.so this servo will go to stopped status. Can you give me suggestion how to find the reason, how to check it. Thank you [/INST] Hello Carry, More ... |
<s>[INST] PowerFlex 70 not using the speed ref from the PLC Summary: The drive shows that the Ref Owner is DPI Port5 but the drive ramps up to 60hz anywayThe plant was recently hit by lightning and there was an AB 1336 Plus running a pump. The PLC was sending the speed reference to the 1336 via an different R I/O card.... |
<s>[INST] PF525: load reduction (e.g. via RPM reduction) when the load is about to exceed the set overload limit. P033 is set as overload current limiet. If P033 < actual current (b003) the motor is stopped and an alarm is raised. When the motor is stopped and alarm is raised seems to be a timer based on the difference... |
<s>[INST] Him module Powerflex 700 series Hey, I have a powerflex 7 00 series drive with a HIM module. We are using HZ as a speed reference. I was asked to edit the user lines so the mechanic can see rpm on user display. I seem to only be able to edit and scale the last two lines on the display how can I keep hz as spe... |
<s>[INST] Kinetix 300 Save/Load Connection/Configuration wanted. Summary: Cannot find documentation explaining Save/Load functions. Please send linkI have to back existing configurations ons Kinetix 300 servo drives before making changes to a machine. I have never worked on these drives. There are Save Connection, Load... |
<s>[INST] Kinetix 6000 High registration input use I have a kinetix 6000 drive and I'm trying to use the high speed registration input (REG1), but I don't know in which tag of the axis can I monitor this input. could someone tell me where can I see the status of this input in the control logix? [/INST] I believe what y... |
<s>[INST] 2094BM01s motor power connector Is there a part number for a replacement motor power ( MP )connector on a 2094BM01S .Customer received one bad connector on his drive. [/INST] Yes, the catalog number is : 2094-XNINV-1 - fuzzy logic \\n </s> |
<s>[INST] PF 400 output frequency problem Summary: drive is not running on commanded frequencyCustomer have power flex 400 Ac Drive, 125Hp. They are using it for Agitator application. For first 12 hour they run drive on 25 Hz its working ok, After that they run it at 50Hz but in this condition drive output frequency au... |
<s>[INST] Common Bus 1336 Drive Spare Parts For common bus 1336 drive (S/F/E/T), cat. no. such as 1336E-R700C-AN-EN (700HP@513-620VDC), is the spare parts list as attached suitable for selection? [/INST] Yes, it is the right one... common bus parts are indicated in tables, this is the only parts list for 1336 Impact. -... |
<s>[INST] Feedback only axis using a CLX SERCOS module Hello, The setup is a CLX processor with a 3 axis SERCOS module controlling one U3K axis. I now need to bring in an encoder as a Feedback Only axis. What's the best way? Any way of getting it onto the SERCOS module. Thanks [/INST] http://literature.rockwellautomati... |
<s>[INST] Synchronization (motion) between three motors using 3 PowerFlex 525 VFDs and 3 encoders? Summary: 05BH00CB02AF encoders motion synchronizationI am trying to setup the motion tracking of a large platform using three motors controlled by three VFDs. These motors have to move at the same pace and be 100% synchro... |
<s>[INST] PF700 two Reference Speed What configuration should I do with PF700 if 2 reference speed is required? Speed 1 - Via PotentiometerSpeed 2 - Analog (4-20 mA) [/INST] Utilize the digital inputs to switch between Reference select 1 & 2 (par 361 - 366) and Reference A & B (par 90 & 93) \\n </s> |
<s>[INST] PLC SCADA integtation easy testing or forcing. I am integrating both PLC and SCADA. I have a signal list and I am putting Jumper across XIC to active OTE in online program edits and seeing responses on SCADA. Putting jumper across XIC ( not IOs to force) taking me too much time to test the program online. Is... |
<s>[INST] I want to do a backup of a Factory Talk View SE network distributed application V7 project, to later move it to a newer server with the V13 application. I planned to use the Distributed Application Manager tool to backup the application, but I can't find it in the old server or in the FT view SE 7 installatio... |
<s>[INST] 10 HP Bucket Modification Question Hello, Was wanting to check and see what y'all thought about a potential modification to the bucket I have attached. We are looking to add another 10 HP motor to one of our tanks, and we are looking to have one motor run for a period of time, then turn off, and then start th... |
<s>[INST] PowerFlex 700S speed control I have a PowerFlex 700S firmware ver 4.002 Series:A and need to control motor speed using a 4-20mA analog input. I have successfully configured and run the drive using Par 14 - Preset Speed 1, encoder feedback, digital inputs 1 & 2 as Enable & Run, but I can't get the analog input... |
<s>[INST] Serial Communications in LabVIEW are giving incorrect data compared to Ultraware Hey all, I am running into an issue with data that I see in Ultraware 3000 compared to what LabVIEW is reading when requesting the same information from the servo via serial communications. my LabVIEW code is basically taking the... |
<s>[INST] RDD Motor Summary: Can I use PF700s to control RDD motor.Hi, I had a project which I plan to use a RDD motor but heard that this only compatible with Kinetix drive. I wanted to use PF700s which we use a lot and I wanted to know if someone here, uses this motor. I need to learn from someone who has hands-on wi... |
<s>[INST] Using a powermonitor 1000 with RSview ME I would like to bring some of the powermonitor datatables into a RSviewMe application. I am using Ethernet to communicate. When I create the shortcut I can see an online folder. I right click and try to refresh. The online folder will not populate with tags. Is it poss... |
<s>[INST] Powerflex 40p - AtPos bit Does anyone know, when the pf40p:I.CommFreqCnt_or_AtPos is exactly set or reset, when working in positioning mode?This is because of timing issues. We issue a new start command, but it takes time that the 'old' AtPos bit is reset. What is the best programming practice to overcome thi... |
<s>[INST] Problem with direction servo motor AB . Summary: how changing the direction of rotation of the servo motor Dear All . I have problem with servo motor AB , when we try with jog motor run forward ,it run reverse. I don’t know how to adjust for motor run direction correct and occur some error E07 & E19 . If ever... |
<s>[INST] PF70 Drive & 20HIMA6 HIM Summary: Can i connect 20-HIM-A6 to PF70 Drive? As i know 20HIMA6 supports PF70 drive. However, what are the limitations coming while programming? Whether all functionality will be available for PF70 drive in 20-HIM-A6 like 20-HIM-A3 ? Is there only certain functions will be activated... |
<s>[INST] Is there a way to setup Optix to a Logix Emulator on the same workstation for testing? [/INST] We use Logix Echo to communicate to FTOptix. https://www.rockwellautomation.com/en-us/products/software/factorytalk/designsuite/logix-echo.html\n </s> |
<s>[INST] Flex cables on TLY motor ? Hi, Is it possible to use continuous flex cables on TLY-series motor? I could not find any indication anywhere that it's possible. I'm looking at : TLY-A2540P-H with 2093-AM02 K2000 drive : power : 2090-CPEM7DF-16AFxx power+brake : 2090-CPBM7DF-16AFxx feedback : 2090-CFBM7DF-CDAFxx ... |
<s>[INST] Where can I find the documents about the configuration for PF755 Point to Point application My system is a lifter controlled by PF755. In this system, there is one 20-750-ENC-1 on VFD port 4 and one 20-750_UFB-1 on VFD port 5. First, I configure 'Port 4:Encoder Feedback' as velocity feedback(Parameter:125) an... |
<s>[INST] Ultarware and Kinetix 3 Summary: Trouble!!Hello, I'm trying to set up a kinetix3 drive with the ultraware software. First, when i enable the drive from the software the display on the drive instantly shows Pot. When i try to jog the motor, i get a error message action cancelled by drive error [/INST] nan \\n ... |
<s>[INST] Cannot Delete or Un-Inhibit PowerFlex module in RS5000 RS5000 Version 18 (recently revved up from 17). Three PowerFlex drives were added to ENBT in IO tree and inhbitied online when controller was 17. Controller revved up to 18 and put back in service a couple of weeks ago. Today trying to commission those th... |
<s>[INST] 755 Parameter 38 Summary: I have a 25HP drive that works best with the switching freq at 2khz. When power is cycled, it defaults to 4khz. Why? [/INST] What is the version of the drive? What is the voltage and amperage of the drive? What are the values of parameters 305 and 306? (Voltage Class and Duty Rating)... |
<s>[INST] 1756-M02AE With PF700S Summary: 1756-M02AE With PF700S Hi! Does anyone know if it's possible to use 1756-M02AE to control PF700S drives? I would like to use the motion instrction in rslogix5000, like MAPC,MAM and MAG to control PF700S drives, Thanks. [/INST] PF700S could be used in a motion application only w... |
<s>[INST] powerflex 700 input We bought a powerflex 700 drive to a US reseller and they confirm us that it is possible to plug it with 3-phase or single phase on input. We try on the French electrical communication (220-240V single phase) but it blows the fuses of our place. Note that the drive works well if we plug it... |
<s>[INST] Kinetix 6000 analog output monitors (0-5V) or (0-10V)? Regarding the output voltage range of the analog output monitors for the Kinetix 6000 drive series : The manuals specify a 0-5VDC analog output voltage range for the monitors. But, I have seen a number of K6000 modules that produce 0-10VDC on the analog o... |
<s>[INST] 1336 Plus II - Can't clear overcurrent fault (12) I have a 1336 Plus II drive that is tripped on overcurrent fault (12) and I can't reset this fault. I have tried resetting with and without the motor leads conected to the drive.I have tried downloading the parameters to the driveI have recycled the powerI hav... |
<s>[INST] Kinetix 6000 y kinetix 6200 en el mismo riel EDIT: I've provided below the translation to the posted text in the quote. Please use the English language when posting so that it can be easily read by everyone. Thanks! - Mark Churchill Estimados es posible trabajar kinetix 6000 y kinetix 6200 sobre el mismo riel... |
<s>[INST] Controlling Backlash with two motors I was wondering if someone has experience in driving two motors in anti-backlash with the Allen-Bradley servo drives? The mechanism rotator has two sets of motor-gearbox drive assemblies to eliminate the anti-backlash, when the mechanism is driven under computer (Controllo... |
<s>[INST] Flying step change I use PowerFlex 700 drive in Pos/Spd Prof mode (Speed/Torque Mod P88). The used profil has 3 steps. First : Type: Encode abs.Second : Type: Encode abs.Third : Type : End Hold Pos. This is what I want to do : I command the first step and while it is running, then I command the second one on ... |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.