Problem Statement: AspenOneのインストレーションでは、ライセンスがSLM サーバーからチェックアウト出来るようにする為、ポートの5093(TCPとUDP)が開いている必要があります。ここではTCP/UDPポートが開いているかどうかを確認する為の方法について説明します。 | Solution: You may use the common 'telnet' command to determine if a specific TCP port is open, but it's not suitable to test UDP ports. Telnetのコマンドを使用して特定のTCPポートがオープンかどうかを確認することは可能ですがUDPポートには向いていません。 UDPポートが開いているかどうかを確認する為にはフリーのユティリティのiPerf.exeを使って以下の方法で確認してください。
//iperf.fr/download/iperf_2.0.5/iperf-2.0.5-2-win32.zip... |
Problem Statement: Can two USB Dongles from AspenTech on the same computer? | Solution: For Standalone Licenses,multiple USB Dongles can be used on the same machine.
For Network Licenses, only one USB Dongle is supported per SLM Server.
Keywords: : Multiple USB Dongles, Sentinel Server
References: None |
Problem Statement: How can license usage be monitored from a client machine? | Solution: For monitoring license usage from user machine, please follow the below steps:
1. Go to Start / All Programs / AspenTech / Common Utilities / SLM License Profiler as shown
2. This dialog box will appear. Select the License server from the drop down as shown. Click on "Load Information" and then on "... |
Problem Statement: How do I decommission a license server? | Solution: This article will explain how to decommission a SLM License Server.
Remove the license file:
1. Go to C:\Program Files (x86)\Common Files\SafeNet Sentinel\Sentinel RMS License Manager\WinNT
2. Launch Loadls.exe
3. Click Remove, this will uninstall the license file.
Uninstall the license server software:
1.... |
Problem Statement: I have a dongle locked license file. When the dongle is plugged in or attached to my machine the locking information shows the corresponding lock code. However, when I try to install license file using aspenONE License File Installer, I get the error message, 'the selected license file has a lock cod... | Solution: If the correct dongle is plugged in and lock code matches with the license file, the error message usually occurs because dongle driver is not installed. Sentinel System Driver needs to be installed, so it can support communications with the device.
How to check if the dongle driver is installed:
Go to C:\P... |
Problem Statement: How do I install a license file on a Redundant License Server configuration? | Solution: Leader Server Configuration:
1. Download the license file on the Leader license server and double click to install.
Click Yes when prompted to install.
2. Click OK while confirming installation a redundancy license file.
3. Provide the hostname & IP address of Follower server and Click Add server... |
Problem Statement: How do I create Software License Manager (SLM) debugging (also known as trace logs) logs on the SLM Server? | Solution: This knowledge base article will explain how to create SLM Server debugging logs. These logs can be used to troubleshoot issues with the SLM Server (for example, the Sentinel RMS License Manager service crashing.).
To create the debugging logs, please follow these steps:
1) Log into the server with an acc... |
Problem Statement: I have multiple Network adapters on my license server. How can I get this type of configuration to work if my license file is locked to a Network Adapter? | Solution: If your license file has been locked to a Network Adapter it is important to ensure that the server recognize that Network adapter that the license file is locked to as the Primary network adapter. Use the following procedure to determine and set the primary NIC on a Windows 2003 Server:
1. Right-click ... |
Problem Statement: How do I use the SLM feature Project Tracking? | Solution: There is a project tracking option within the SLM Configuration Wizard that companies can use to assign a computer to be attached to a project by site and department.
Project Tracking, when enabled, tracks your license use by project. The Project Tracking page allows you to enable or disable job tracking. If ... |
Problem Statement: The LSHOST Environment Variable is used to direct the search for a network license to a list of
preferred servers. | Solution: 1. On your main desktop, right click on the My Computer icon, and select Properties.
2. Select the ADVANCED tab.
3. Click on the Environment Variables button.
4. Under the section called "System variables for...." check to see if you have an LSHost variable.
If ... |
Problem Statement: How do I verify the redundant license server is running? | Solution: 1. Launch WLMAdmin using aspenONE SLM License Manager on Leader and Follower server.
2. Expand the license server hostname, it should display big list of license keys.
3. Redundant: Yes means this license server is configured using redundancy license file.
4. Redundancy Info tab will display Leader and ... |
Problem Statement: How to configure Socket Buffer on a SLM License Server? | Solution: SLM Server is configured to use default socket buffer of 65535 bytes, customers with higher license usage are recommended to increase SLM Server socket buffer. This article will explain how to increase socket buffer for SLM Server.
SLM Client and Server communicates through Windows Sockets. The default socke... |
Problem Statement: Why do license usage logs show "Grace" entries? | Solution: The AspenTech License server will add the string :Grace in the usage log when a transaction has been logged for a product that supports grace functionality during check out or release of a license key used by products like Process Explorer, InfoPlus.21. etc.
01:0:0:0:10.10.10.10:5:357:IP21.Process.Browser_1... |
Problem Statement: The previous network token license file contained a license feature called AEA_Token that contained all the tokens that had been purchased. Now the new network token license file no longer contains the AEA_Token feature. | Solution: In newer versions of the SLM license files, the AEA_Token license feature was replaced with the SLM_Pool license feature which now contains the total number of tokens that were purchased by the customer.
This change does not alter the total number of tokens that the customer has purchased.
The only necess... |
Problem Statement: Why is my dongle not detecting in the SLM Configuration Wizard and showing an exclamation mark in the device manager? | Solution: This can be caused when the dongle driver is not installed, corrupt, or out of date. You will need to install the dongle driver to resolve this issue.
AspenTech's standard practice is to install the dongle driver from the SLM Tools located on the aspenONE DVD media. An alternate solution is to install the do... |
Problem Statement: This Knowledge Base article provides steps to decommission a License Server that is no longer used. | Solution: The best way to decommission a License Server that is no longer used is to completely uninstall the Aspen SLM Server from the computer. Please follow these steps to do so:
1. Log in to the computer hosting the old License Server.
2. Uninstall SLM Server, SLM tools and Sentinel RMS License Manager th... |
Problem Statement: How to verify that your reservation file is initialized. | Solution: If you need assistance on how to create a reservation file, visit this article: How to create a reservation file
To verify if a reservation file has been initialized successfully you can check by using the WLM Admin.
Open SLM License Manager and then open the WLM Admin tool
Select the License Server the res... |
Problem Statement: I have configured to use both standalone and network license. How can I check if I am using the standalone or network license? | Solution: Open an application e.g. Aspen HYSYS and then go to "File or Help --> About --> Licensing information"
On the licensing information, if you see 'no net' on the license location, it means you are using standalone or commuted licenses.
If you see your license server name e.g. 'atuklic1' on the license location ... |
Problem Statement: When open Aspen Software, get error message All licenses are currently in use, click Details, you will get error code 26, Your license is disabled due to an inconsistency in the computer's clock or a corruption in the system folders. | Solution: The reason why this error occurs is due to the license registration is missing, corrupted or a computer's date/time changed. There are two possible solution to fix an error 26.
Register the License
Run the aspenONE SLM License Manager and click the Configure button.
When the Configuration Wizard opens, add ... |
Problem Statement: How do I restrict a Machine or an IP Address or a Subnet Mask from using a license? | Solution: In order to restrict a Machine or an IP Address or a Subnet Mask from using the license file, a reservation file will need to be created and added to the license server.
To create a reservation file, follow the instructions from KB 000022087.
After creating the reservation file, you may add the Machine Name... |
Problem Statement: Which License Server folders are recommended to be excluded by third party virus scan applications? | Solution: In order to prevent third party virus scan applications from interfering with license checkouts, it is recommended that the following folders are excluded from the scanning routine:
C:\Program Files (x86)\AspenTech\
C:\Program Files (x86)\Common Files\AspenTech Shared\
C:\Program Files (x86)\SafeNet Sentinel\... |
Problem Statement: How should I correct an SLM Error 15 “User Excluded" when launching an Aspen product? | Solution: This error will occur when a user launches an Aspen product and their username, computer name, or IP Address has been included in a group reservation that has been created to block certain users/computers from running some of the Aspen applications.
This file is located on the license server computer in the... |
Problem Statement: Microsoft frequently releases individual hotfixes for the Windows operating systems to fix defects and to patch security loopholes. End users often inquire whether or not these individual Microsoft hotfixes are compatible with the Software License Manager (SLM) products. This knowledge base article d... | Solution: AspenTech tests new versions of the Software License Manager (SLM) with the latest Microsoft service packs and Microsoft hotfixes which are publicly available from Microsoft when the testing cycle begins for a new release. After product testing is completed and the new SLM version is officially released, no a... |
Problem Statement: How to determine how many tokens an AspenTech product will consume when launched? | Solution: You can view the number of tokens needed for each Aspen Product by using the SLM License Profiler located on the Start | All Programs | Aspentech | Common Utilities | SLM License Profiler (V8.7 and below) or Start | All Programs | Aspentech | Aspen SLM | aspenONE SLM License Manager | License Profiler (V8.8 a... |
Problem Statement: What can be done if a license file has been accidently encrypted in the following ways:
1 - encrypted by SEE (Symantec Endpoint Enterprise)
or
2 - encrypted by the operating system - for example Windows 10 | Solution: See attached document for more information.
Keywords: None
References: None |
Problem Statement: Is there a way to implement the token conversion utility on many client machines without having to run the utility on every client? | Solution: This article will help user to create a registry key and roll out to users machine to convert Standard (non-token) installation to Token installation.
Please follow below steps to create a registry key:
1. Run Token Conversion Utility to convert the installation from Standard to Token on a machine.
2. Go t... |
Problem Statement: How do I determine how many tokens are available on my license server? | Solution: If you have a network license you can check the total number of tokens you have using the SLM License Profiler. This knowledge base article will explain the steps involved.
Step 1: Load the SLM License Profiler. This is included by default on every machine that has aspenONE installed.
Click on Start --> All P... |
Problem Statement: What information should be provided to AspenTech to get Commute or Time fix (error 75 or 26)? | Solution: License System Name from the license server.
V8.8 and above:
Launch aspenONE SLM License Manager
Click on License Profiler tool
Select License Server
Click on Load information
Collect the SYSTEM Name and sent it to us
V8.7 and below:
Start || All Programs || AspenTech || Common Utilities || SLM License Profil... |
Problem Statement: In the AUT, can the email notification CC other emails? | Solution: No, the AUT does not CC other emails. You will need to use an email distribution group and set AUT to send the notifications to the distribution group.
Keywords: AUT, Email, Usage Logs
References: None |
Problem Statement: Which switches are available for configuring LServOpts environment variable. | Solution: LServOpts environment variable will get created on license server by default to generate usage logs.
The table below lists the various options that can be set using:
LSERVOPTS - The environment variable that can be used to configure the License Manager.
Command-line - The options can be set on both Windows a... |
Problem Statement: Why do I get the error “License Limit Reached for AspenTech Products” when opening an Aspen product? | Solution: If you open an Aspen product and the error “License Limit Reached for AspenTech Products” is displayed, it most likely indicates that all your licenses or tokens have been checked out and you will need to wait for someone to return a license or tokens.
To confirm this, you may use the SLM License Profiler to ... |
Problem Statement: What do we need to do to migrate to a new license server? | Solution: Before decommissioning your existing license server, setup your new license server with the required drivers and software.
Dongle-Locked License (locked to a usb security dongle):
Install the latest version of the aspenONE SLM Software on the new license server.
Obtain it from the Download Center: https://esu... |
Problem Statement: When to select Install and Upgrade Options in aspenONE V12 Installer? | Solution: When aspenONE V12 software is installed on a computer, the Installer will check for the presence of any AspenTech software already installed on this computer. If any of the products/components on the computer are determined to be upgradable, the Installer will provide the Upgrade option as shown below.
Users... |
Problem Statement: License files on Virtual Machines are typically locked to hostname and/or IP-address. There may be situations where the IP address is not assigned by the time the Sentinel RMS Licensing Manager service starts up on a server. In these situations, the Licensing Manager service cannot validate the licen... | Solution: We recommend to enable automatic delayed start of the Sentinel RMS Licensing Manager service. Here are the steps:
Steps for setting the Sentinel RMS Licensing Manger Startup option to “Automatic (Delayed Start)”:
Open a Services Microsoft Management Console (MMC): [Start | Control Panel | Administration Tool... |
Problem Statement: How to display the Area enclosed by layout (Ap) and Perimeter of layout (Cp) to U-tube calculation details | Solution: Starting in V12, the user can display the Area enclosed by layout (Ap) and Perimeter of layout (Cp) under the Tubesheets/Expansion Joints results
Keywords: Ap, Cp, Tubesheets, UHX-12.5.9
References: None |
Problem Statement: How can I access Aspen Version Comparison Assistant (AVCA)? | Solution: You can find this tool in the Start menu | Aspen Engineering Tools
AVCA is installed automatically when installing aspenONE Engineering suite.
NOTE: Please be aware that Aspen Version Comparison Assistant will not work on any version before 2006.5.
Keywords: Aspen Version Comparison Assistant
References: No... |
Problem Statement: How to use the aspenONE EP Installer? | Solution: The new EP Installer provides a standard method for installing Emergency Patches (EP’s) with V12 going forward for all AspenTech products. It is delivered as a .EXE and is used to deploy V12+ EP’s.
Depending on the product being patched, the installer may need to stop and restart services, or require a reboot... |
Problem Statement: What does Amine Circulation rate mean? | Solution: The Circulation rate is the flow rate of the amine stream that circulates between the absorber and regenerator. Includes the flow rate of the amine stream including all components (amine, water and acid gas, etc.) in the stream.
The Recirculation Rate are reported at Std Ideal Liq Vol Flow. Find more informat... |
Problem Statement: What are some of the common issues while using Aspen Multicase and how can they be addressed? | Solution: This attached pdf file highlights some of the common issues you may see while using Aspen Multicase and possible solutions.
Keywords: Aspen Multicase, issues, unconverged, does not start, unable to find variables, trace components
References: None |
Problem Statement: How to co-exist with third party software that uses Rainbow or "SafeNet Sentinel" license manager?
SLM uses Rainbow (SafeNet Sentinel) license manager for its base product, however some third-party software uses the license manager too. And, if the third-party software uses the environment variable... | Solution: With AspenTech products, the environment variables LSHOST and LSFORCEHOST supersede the license server settings in the registry. And further, LSFORCEHOST supersedes LSHOST.
AspenTech products do not need these environment variables to search for the license server. So, if the third-party software does not n... |
Problem Statement: Why do I receive following license error even when pointing to the correct license file and the license server is configured properly:
Unable to acquire [Product Name] license.
Error Code: 18
Description : The license for this product or feature could not be found. Be sure you are pointing to the cor... | Solution: The communication ports that the AspenTech SLM uses are:
TCP Port 5093
UDP Port 5093
TCP Port 5094
UDP Port 5094
If the Firewall is turned on, you will need to set some exceptions to the ports, so that the SLM licensing can work properly.
To add port Exceptions:
Start "Windows FireWall"on Control Panel
Wi... |
Problem Statement: What is Reservation and how to create Reservation file? | Solution: Reservations let you associate user groups with each feature. A certain number of licenses for that feature are then reserved in a pool for these user groups. Any licenses not specifically reserved remain in the general pool.
Please follow attached presentation to create a Reservation file.
A group specific... |
Problem Statement: How can I automate the SLM Configuration settings on multiple clients? | Solution: While SLM does not provide a mechanism for exporting license configuration settings, it is possible to perform this task by exporting the Windows Registry Key that holds the SLM Configuration of a client that is already configured and has been tested. Once the SLM Configuration File is exported and saved as ... |
Problem Statement: Unable to install a standalone license file remotely on a user machine.
Error " You are attempting to install this license file on a remotely connected machine, but the license file is not valid for remote connection (it is missing the 'SLM_AllowRemoteSession' license). Contact AspenTech to obtain a... | Solution: This issue will occur if a standalone license file is installed remotely from another machine. Standalone license files are not designed to be used on multi user machine or on a VM.
Install standalone license file manually by following below steps:
a. Remove all old license files from C:\Program Files (... |
Problem Statement: Why do I get the license error code 12 “Internal error in SentinelLM”?
Problem Description
-------------- SLM Common Error Dialog ---------------
Application: AspenHysys.exe
--------------- Information Flags ---------------
Error while checking out license HYSYS_Process
--------------- Sequence of ... | Solution: This error indicates version incompatibility issues between SLM Server(s) and AspenONE Client Software. In this case, the Software License Manager (SLM) License Server must be upgraded to a higher version in order to get rid of error code 12. Please refer to Knowledge Base 146299-2 entitled “What is the compa... |
Problem Statement: How do I check if my license server has a specific product key in use? | Solution: This knowledge base article describes how to find if your license server has a specific product key in use.
Launch aspenONE SLM License Manager and click on License Profiler
Select the License Server, click Load Information, and View Licenses
The Name shows all the license key names a... |
Problem Statement: Aspen Watch Shows Run status OldRunTime waiting – Possible root Couse and troubleshooting . | Solution: Make sure the following configurations are correct:
1. Time Zone , timestamp and daylight savings time auto adjustment need to be all the same .
2. Check the CIM-IO_logical_devices.def file to make sure you do not have duplicate entries anywhere.
verify the DLGPServiceName (3rd column is correct) and ve... |
Problem Statement: CIM-IO_MSG.LOG shows WNT Error 1314 -A required privilege is not held by the client.
29-MAR-2021 05:47:00.091, Logged by CIMIOManager on node xxxx: Win32 error 1314 logging on as xxxx for server xxxx
29-MAR-2021 05:47:00.019, Logged by CIMIOManager on node xxxx: CIMIO_MGMT_SERVER_LOGON, Error logging... | Solution: In order to resolve this issue, the local security policies need to be updated. Specifically, the account used to start CIM-IO Manager need to be added to the Local Policies for:
Act as part of the operating system
Log on as a batch job
Log on as a Service
Replace a process level token
Go into Control Panel ... |
Problem Statement: In PCWS Controllers last run time does not match with the system time . | Solution: When the PCWS server system time is changed you need to restart the Aspen APC web provider data service .
Key words:
PCWS , time sync
Keywords: None
References: None |
Problem Statement: When running the Aspen Operations Dashboard (the editor, viewer or image server), after about 15 minutes an error will appear stating "The demo license has expired." If you are running the dashboard editor, and you haven't yet saved your dashboard, clicking ok to this error will remove all components... | Solution: This error can happen for two reasons, both having to do with problems loading the license key for the RTView (the editor, viewer or image server) component.
If you are running the dashboard from within the Aspen RBV (Role Based Visualization) portal, the error is mostly likely occuring because the MIME type ... |
Problem Statement: As mentioned in the mMDM Help text, the Property list is a master list of all possible properties for all materials. The Property list on the Material Details tab is intended for overriding default values for properties, not for assigning properties.
mMDM is a reference (master data) system that can... | Solution: One solution for assigning properties to materials is to create a class with an array of Property type references, then assign the class to each material. You can then use this list to limit the properties queried for from the material.
Note: If the organization foresees the case where there could be more ... |
Problem Statement: This Knowledge Base article describes how definition lifespans are handled in Aspen Manufacturing Master Data Manager (mMDM). | Solution: Please download and review the attached document titled:
Aspen mMDM Definition Lifespans
Keywords:
References: None |
Problem Statement: In a Pipeline Area Project, how do I fix the following error message?
ERROR> 'GP - 1' QUESTION MARK FOUND IN NUMERIC DATA | Solution: This message appears in a Pipeline project in ACCE when there is missing information on the Area specs of the Pipeline areas.
When a new Pipeline Project is created, ACCE will automatically add a new Pipeline Area, however the Area specs for this item will not have default values for all parameters, so the us... |
Problem Statement: Recent Windows versions support Text Scaling at High DPI screens, but it doesn't work well for some legacy application. The issues include: texts blur, element dislocation and element disappear. | Solution: Text Scaling can be disabled for per application. Here is a workaround for the issue if you have to enable Text Scaling for other applications because of High DPI screens:
Find the DMC3 Builder (or any other application has issue under Text Scaling) )in Start Menu and right click it.
Select Open file location... |
Problem Statement: How to resolve Aspen CIM IO Communication issues related to WNT Error messages and corresponding KB articles | Solution: WNT Error Cause of the error KB Article to refer
"WNT Error=10054 An existing connection was forcibly closed by the remote host"? These messages indicate that the network connection is being closed by an external mechanism or program. When this occurs the data transfer stops briefly then the "10054" message i... |
Problem Statement: How to Map LIMS data to IQ . | Solution: Setup interface to map the tag in .IQF file for that :
If data is collected in IP21 – setup CIM_IO for IP21 interface
If data is directly collected in OPC and interface needs to be done from CIM-IO for OPC .
After successful interface – Please change settings and parameter I .IQF file .
You might need to set... |
Problem Statement: In the APC Centralized Benefits Monitoring User Guide, the Process Data Configuration section (page 9) explains that to enable the APC Benefits Monitoring page, the ATProcessDataREST.config file must be modified to specify the data source (server where Aspen Watch is installed or a centralized server... | Solution: In the factory installation of the MSC V11 Suite, multiple data sources are not supported. When modifying the ATProcessDataREST.config file, the user can only specify one data source. As a result, one Web Server can only display the Benefits Monitoring data from one Aspen Watch Server.
However, MES V11.0 Cu... |
Problem Statement: In the View Trend window within Aspen Mtell Agent Builder, the following buttons may be missing:
View Excursions
View Metrics (no longer available in V12)
Probability Trend
View Failure Details
Export Data
Save Agent
Close | Solution: One potential solution is to decrease your zoom setting.
1. Open Windows Settings. If you are working on a virtual machine (VM), you will need to open Windows Settings on your host computer.
2. Select System.
3. On the left sidebar, select Display (if it is not already open).
4. Under Scale and lay... |
Problem Statement: What are the Expansion Templates and how to use them? | Solution: The Expansion Templates are built diagrams frequently used of multiple equipment connected.
The Expansion Templates are configurations of multiple equipment and connectors. These can be placed in a drawing to save time for a frequently used configuration like distillation columns (with condenser and reboiler... |
Problem Statement: This Knowledge Base article shows how to use the aspenONE Process Explorer (a1PE) Trend Plot in a separate web page or iframe with a URL. | Solution: The a1PE Trend Plot can be used in a separate web page or iFrame with a URL such as:
http://localhost/ProcessExplorer/WebControls/PBPlots.asp?outsidea1=graphic&tag=ATCP301
... or this one without the Legend and TimeLine:
http://localhost/ProcessExplorer/WebControls/PBPlots.asp?outsidea1=graphic&tag=ATCP30... |
Problem Statement: When migrated to Office 365 and ASW V10, Aspen Properties, Aspen Simulation Workbook asks to enable every time when open MS-Excel. | Solution: 1. Disable all other non-ASW Excel addins.
2. The registry key for ASW may have been switched from “load at open” to “do not load at open”, which makes the ribbon disappear upon launching Excel.
3. Go to the Registry Editor (regedit),
4. The LoadBehavior value should be set to 3 as in the below path:
Compute... |
Problem Statement: This knowledge base article explains the steps to resolve an issue where when trying to register the Aspen Properties databases using the database manager with a remote SQL server, an error will display "No more properties database is available in Server .... Select a Different Sever.". | Solution: The machine may already have local databases that were registered on the machine.
Open the database manager and right click the already registered databases and select Delete Database Registration for all four databases. After deletion, try connecting to the remote SQL server and register the databases.
Key... |
Problem Statement: There is not possible to use the Copy & Paste options for a curve on the Non-Linear model on DMC3 Builder, but there are some parameters that can be changed in a curve to make it exactly like another one. | Solution: For this procedure, we are going to copy the corresponding curve for the model between CV1 and MV2 to the model curve for the model between CV2 and MV2.
The steps to perform the procedure are the next:
Click on Build Models.
Make sure that in the Inputs tab, the model you desire to modify has a check on the ... |
Problem Statement: Why do I get the error message ‘Cannot find the SCHEMA entry in Software\AspenTech\AspenBasicEngineering\19.1\Simulators\Provision’ when attempting to import a PRO/II model into ABE V10? | Solution: The purpose of this article is to describe the procedure to import PRO/II models built in V9.3 or newer versions (specifically PRO/II V10 models) into ABE V10. If after following the instructions described in this article, the user still deals with problems, please contact AspenTech Support for help (esupport... |
Problem Statement: In Aspen Basic Engineering Mapper, what are the different stream classes used for? | Solution: When using Mapper tool to map streams from the simulation, users have the following options:
PFDPipingSystem
ControlPipingSystem
MaterialPipingSystem
InstrumentLine
PrimaryPipingSystem
SecondaryPipingSystem
UtilityPipingSystem
These stream classes hierarchy can be represented with the schematic below:
Fro... |
Problem Statement: In Aspen HYSYS's liquid density calculation of TEG, would using Volume Translation value from a third party tool provide a valid result? (For example, using PVTSim's Cpen Peneloux volume correction for Volume Translation term entry) | Solution: Because HYSYS uses a different value for TEG critical pressure than other literature (please refer to article 47396), Volume Translation value calclulated from outside tools will not be compatible with HYSYS. However, since property models inside HYSYS have been re-parameterized to account for HYSYS's incorre... |
Problem Statement: Is slug flow analysis in Flare Analyzer System based on the same method used in HYSYS? | Solution: In HYSYS, a mathematical model based on mass and momentum equations was developed to identify slug flow possibility. The model involves study of the traveling waves solutions and flow stability test. M Watson developed this model and described the detailed methodology in his paper: Watson, M., "The Modelling... |
Problem Statement: How to transfer the simulation into different cases using ABE Mapper? | Solution: A case is a collection of descriptive values for objects and connections. Cases typically reflect different situations that would affect the same datasheet, e.g. operating conditions in summer and winter. Its scope does not cover topological cases where the number of objects, or connectivity of the same objec... |
Problem Statement: Starting from V8.7, similar to other client applications, aspenONE Process Explorer (A1PE) can be secured using AFW Security. This solution demonstrates the procedure to enable security for A1PE. | Solution: To secure A1PE using AFW:
1. log on to AFW Security manager from Start | Programs | AspenTech | AFW security Manager
2. Right Click on Application | All Tasks | Import Application | Browse to C:\Program Files (x86)\AspenTech\ProcessData
3. Select AspenMESClientApplications_AFW.xml click on OK
4. Once the app... |
Problem Statement: After migrating to ABE V11, some attributes of data type "Real" fail to report data that had been assigned to it in previous version. | Solution: A properly defined attribute has Quantity Type associated with it to show correct units of measure. When migrating to ABE V11, attributes of data type "Real" without a Quantity Type defined will be automatically updated with Quantity Type "Dimensionless," as there is no way for ABE to reliably guess the Quant... |
Problem Statement: Nothing happens when I try to run the old reporter in Aspen Economic Evaluation. No widow appears after trying to launch the interactive reports. | Solution: One of the latest updates in Microsoft Office broke the connection between the Old Icarus Reporter and Microsoft Access Database Engine. This in turn does not allow any application to correctly launch the Icarus reporter. The user can confirm this behavior by looking at the task manager, no instance of the Re... |
Problem Statement: Where can I find the Project Schedule generated by ACCE? | Solution: After a Project Evaluation in Aspen Capital Cost Estimator, a Project Schedule is generated through the Critical Path Method (CPM). This schedule is reported as three different views:
General schedule, which shows a simplified view of the full schedule
Engineering schedule, which shows more details on enginee... |
Problem Statement: Why am I seeing different results / stream properties when opening the same case on two different machines? | Solution: First of all, the users should confirm that the version and patch numbers are the same on both machines that have been used to open the simulation file. Since the internal parameters used to solve the flowsheet may have changed as a result of fixes or improvements, it is possible to obtain different results.
... |
Problem Statement: When running a case study and adding the Flow Regime of a pipe segment as the dependent variable, this is displayed as a number instead of the text in the results tab. Which is the numerical correspondence to the different flow regimes and flow correlations? | Solution: Inside of a case study that uses the Flow Regime of a pipe segment as a dependent variable, the flow regime will display as a number. The following is a list with the numerical correspondence of the different flow regimes and correlations:
Value Flow Regime Correlation
0 Liquid Only -
1 Vapour Only -
2 Aque... |
Problem Statement:
Some older versions of Internet Explorer (IE) cannot load the Prerequisites Viewer web page correctly. | Solution:
Aspen recommends that you update to the latest version of Internet Explorer, or use Microsoft Edge/Google Chrome web browser. The Prerequisites Viewer web page should look like this:
Keywords: aspenONE Install
Product Prerequisite Requirements
References: None |
Problem Statement: Unable to install Aspen 32bit and 64bit products when they are on different drives.
A defect was introduced in aspenONE V8.4 release where it allows a user to select different drives and root paths as destination for aspenONE 32-bit/64bit installation. If the installation drives are different betwee... | Solution: Uninstall the existing 32-bit/64-bit aspenONE applications and reinstall them on the same drive.
Correct Settings:
Incorrect Settings:
Keywords: aspenONE Install
Aspen Engineering Suite (AES)
Manufacturing and Supply Chain (MSC)
Asset Performance Management (APM)
References: None |
Problem Statement: FAQs regarding multi-user accessibility and file sharing availability for APC / DMC3 Builder | Solution: 1. Can multiple people use the server at the same time?
It is Microsoft’s requirement that any Windows Server OS by default allows up to 2 users to be remoted into the machine at the same time. Therefore, up to 2 users can run DMC3 Builder on the same server at the same time without any problem. To use Window... |
Problem Statement: How do you model Penicillin recovery by extraction? | Solution: Example Files
This example is delivered with Aspen Plus as the files pen.bkp, penext.f and penfrm.f in the the Aspen Plus GUI directory in a sub-directory called app.
Before running this application, you must copy the Fortran subroutines penext.f and penfrm.f from the application directory to your working dir... |
Problem Statement: How do you model Sour Water Stripping? | Solution: Example Files
This example is delivered with Aspen Plus as the files sour.bkp and sour.tff in the the Aspen Plus GUI directory in a sub-directory called app.
Copy the SOUR.TFF from the APP directory to your local directory to view the stream results with the application customized stream report format.
Proces... |
Problem Statement: How do you model an atmospheric crude tower? | Solution: Example Files
This example is delivered with Aspen Plus as a file called cdu.bkp in the the Aspen Plus GUI directory in a sub-directory called app.
Process Overview
This application uses the Aspen Plus PetroFrac model to simulate an atmospheric crude tower. It uses the tray-sizing and tray-rating features to... |
Problem Statement: How do you model the separation of acetone and methanol using water to break the azeotrope? | Solution: Example Files
This example is delivered with Aspen Plus as the file solvent.bkp in the the Aspen Plus GUI directory in a sub-directory called app.
Process Overview
Solvents from various pharmaceutical processes are separated in a series of distillation columns. The solvent mixture includes acetone, methanol,... |
Problem Statement: How do you model gas drying with triethylene-glycol (TEG)? | Solution: Example Files
This example is delivered with Aspen Plus as the file as teg.bkp in the the Aspen Plus GUI directory in a sub-directory called app.
Process Overview
The absorption column removes water from the gas stream. TEG is the liquid desiccant.
Model Approach
A sensitivity study shows how the water cont... |
Problem Statement: Is it possible to use the Aspen Properties Excel Add-In to analyze azeotropic behavior? | Solution: This example illustrates how to use the Aspen Properties Excel Add-In to analyze azeotropic behavior. Azeotropic compositions and temperatures (at constant pressure) are calculated for binary and ternary systems. The temperature dependence of a binary azeotrope is also evaluated.
Knowledge of azeotropic behav... |
Problem Statement: How do you analyze and understand the solubility of a complex drug, specifically the weak base fluconazole, as a function of temperature and pH? | Solution: Aspen Properties is able to describe the solubility of complex substances because it correctly accounts for fluid nonideality and aqueous chemistry. This capability is demonstrated by analyzing the aqueous solubility of fluconazole.
Solubility of drugs in solvents is an important part of the analysis and manu... |
Problem Statement: Is it possible to use the Aspen Properties Excel Add-In to analyze solubility processes in drug research and production? | Solution: This example illustrates how to use the Aspen Properties Excel add-in to analyze solubility processes in drug research and production. The predicted and correlated solubility of aspirin in several solvents and solvent mixtures is first evaluated, and then the application to typical solubility processes is dem... |
Problem Statement: Is it possible to use the Aspen Properties Excel Add-In to analyze evaporative losses from spills? | Solution: This example implements a method described by Peress (Peress, Jimmy, "Estimate Evaporative Losses from Spills," Chemical Engineering Progress, April 2003, page 32) to estimate the evaporation rate when an organic liquid is spilled on the ground. This method is rather simple, but is nevertheless useful to obta... |
Problem Statement: How do you use Aspen Properties and Excel to calculate the pressure of a fixed-volume system, for example those found in batch reactors?
Batch reactors are charged with a certain amount of material. The chemical composition of the mixture and the temperature changes as the reaction proceeds. The pres... | Solution: This example demonstrates how you can use the Aspen Properties Excel add-in to predict and understand these pressure changes and thus design an experiment for safe operation.
How To Use It
The example uses a ternary mixture of water, ammonia and nitrogen as a representative reactor charge. In order to run the... |
Problem Statement: Study of a Gas-Gas Heat Exchanger in Ammonia Synthesis | Solution: This application demonstrates the use of Excel Aspen Properties to analyze a counter-current heat exchanger. The heat exchanger is taken from an ammonia plant where the reactor effluent, following steam generation, is used to heat the incoming gas. The user specifies the incoming flow rates, the extent of con... |
Problem Statement: Do we have an example of a CAPE OPEN standalone property package? | Solution: The implementation of the code inside the CAPE OPEN components, such as how to develop a thermodynamic package, is not the responsibility of AspenTech. What we support is the usage (i.e. calling) the CAPE OPEN components of Aspen Plus.
Attached to this Solution is material developed to illustrate the system u... |
Problem Statement: How can we compute the actual critical point of a mixture? | Solution: This sort of calculation only makes sense with a property method based on an equation of state (EOS). It has to be said that ordinary cubic equations of state such as the popular RK-SOAVE and PENG-ROB are not particularly accurate near critical, besides being limited to hydrocarbons and light gases only.
In p... |
Problem Statement: Is there an example of how to use Heuristic Method Calculations for Steady-State Detection? | Solution: Use the attached spreadsheet to help determine appropriate values for the Light Filter, Heavy Filter, Tolerance and Trend Tolerance for a plant data tag.
KeyWords:
Keywords: None
References: None |
Problem Statement: How do you access existing prop-set properties in order to calculate another user prop-set property? For example, is it possbile to calculate the Wobbe index which equals the following:
Wobbe Index = NETHEATV/(SGRELAIR)^0.5
NETHEATV = Net heating value of a stream (available as the prop-set property ... | Solution: The CALUPP property monitor is used to calculate the prop-set properties listed in Chapter 4 of the Physical Property Data
Keywords: None
References: Manual. See |
Problem Statement: Is it possible to model and isomer separation such as that of para and meta-xylene? | Solution: As long as both molecules are in the databanks or have different properties, it should be possible to separate them.
Attached are two examples of a reactive distillation para and metaxylenes separation using tert-buylebenzene as a reactive solvent:
The first uses an equilibrium reaction (xylene11.bkp)
The sec... |
Problem Statement: Is there a way I can model a single stage batch separation (flash) in Aspen Plus? | Solution: The way model a batch flash, without the use of Aspen Dynamics, is to employ the batch reactor model in Aspen Plus, RBatch. RBatch can be used in Aspen Plus without a reaction set by unchecking the Reactive system box on the Setup\Reactions sheet. In such a case it becomes simply a batch flash block.
See the ... |
Problem Statement: Attached is a simulation of 85 wt.% benzene and 15wt.% anthracene. Both liquids are heated up from 25 deg C at 1 bar to 220 deg C. Benzene has a boiling point of 80.09 deg C, and anthracene has a boiling point of 342.03 deg C. Therefore, shouldn't the vapor fraction at 220 deg C be approximately 0.85... | Solution: The amounts of the coexisting phases and the vapor fraction of a binary mixture can be derived from its phase equilibrium (T-xy) diagram.
The attached figure shows the T-xy diagram of benzene-anthracene at 1 bar. The red dot represents the overall or initial composition. It is located in the 2-phase region.
... |
Problem Statement: How does one pass a parameter variable from excel/VBA to a calculator block? | Solution: Please see the attached example file. There are a few basic steps.
First, define the variables for the calculator block (in Aspen Plus) and declare the variable type as PARAMETER, and be sure to enter an initial value at the bottom of the form . It is a good idea to set the Information Flow setting to EXPORT ... |
Problem Statement: How to determine density model parameters for an electrolyte system | Solution: Density data are supplied in the form of temperature, pressure, composition, and the density or molar volume of the liquid mixture. These data may be used to determine the parameters for the Clarke density model. For more details on this model see the Physical Properties Methods and Models reference manual.
B... |
Problem Statement: How can I model a Steam Ejector in Aspen Plus? | Solution: Steam ejectors can be modeled at various levels of detail. In general they are designed to pull a certain level of vacuum for a certain range of gas rates. A typical application is to maintain a set pressure at the top of a vacuum distillation column or a set of columns. Modeling them predictively from first ... |
Problem Statement: How is it possible to regress WATSOL parameters?
How do you format the data to be regressed?
The only type of data that can be entered to regress WATSOL paramters is WATSOL data. What is WATSOL data? | Solution: WATSOL data on the Properties\Data form is water solubility, i.e. the mole fraction of water in the organic (liquid 1) phase of a two liquid phase system of water and the organic component.
In the attached file, Data for the water solubility of benzene in water was added. Then, the WATSOL parameter was regres... |
Problem Statement: How do I get the Aspen Plus 11.1 Getting Started Guides in Japanese? | Solution: The Aspen Plus 11.1 Getting Started Guides are now available in the Documentation area of the online Technical Support Center.
Japanese fonts need to be installed to view the files properly.
The following Getting Started Guides are available:
Aspen Plus Getting Started Building and Running a Process Models
A... |