ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 307
|
6 Trouble shooting by Event log
304
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
To allow a larger reference torque the system parameters need to be
updated.
50356, Ordered MaxForce is too large
Description
The parameter MaxForce in instruction FCRefSprForce is larger than
the configured maximum value.
Consequences
The parameter MaxForce has been reduced to the configured
maximum value.
Recommended actions
To allow a larger value the system parameters need to be updated.
50357, Ordered MaxTorque is too large
Description
The parameter MaxTorque in instruction FCRefSprTorque is larger
than the configured maximum value.
Consequences
The parameter MaxTorque has been reduced to the configured
maximum value.
Recommended actions
To allow a larger value the system parameters need to be updated.
50358, Close to singularity when in force
control
Description
Close to singularity when in force control mode for robot arg .
Recommended actions
Modify path away from the singularity or change to joint interpolation.
50359, Path Recorder on StorePath level not
allowed
Description
The Path Recorder can only be used on base path level. The Path
Recorder has been stopped.
Recommended actions
Stop Path Recorder before StorePath, restart it after RestoPath.
50361, Brake release error
Description
Too large position error of joint arg after brake release.
Recommended actions
Try once more. Check cables. Check hardware. Check tuning if error
on additional axis.
50362, Brake release time out
Description
Joint arg was not in position after max time for brake release.
Recommended actions
Try once more. Check cables. Check hardware. Check tuning if error
on additional axis.
50363, SyncMoveOn failed
Description
Starting synchronized movements failed due to an internal error.
Consequences
It is not possible to restart the programs from the current position.
Recommended actions
Move the program pointers and try again.
50364, Axis in current vector mode
Description
Warning: Joint arg is configed in arg data as a current vector axis.
Drive system will be disconnected for this axis during normal
operation.
Recommended actions
Run service program to activate the current vector.
Set configuration data for the DRIVE SYSTEM parameter
current_vector_on to FALSE, for normal operation..
50365, Cyclic Brake Check Warning
Description
Cyclic Brake Check has failed
Consequences
Cyclic Brake Check has detected that robot arg may have reduced
brake perfomance on axis arg .
Recommended actions
Repeat the test to verify the result.
50366, Reference Error
Description
An error has occurred in the reference calculation. Internal status arg .
Consequences
The controller goes to Motors Off
Recommended actions
Check the error logs for previous errors that could be causing this
problem.
Try to restart the program possibly after moving the program pointer.
Restart the controller.
6 Trouble shooting by Event log
305
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50367, Sensor Sync machine stop
Description
Sensor Sync device arg has set machine stop signal arg .
Recommended actions
Do not restart robot before machine is open. Sensor sync is disabled.
50368, Too Short distance between equidistant
events
Description
The events are too close together. End of internal resources (events).
Task: arg
Program Ref. arg
Recommended actions
Increase the distance between equidistant events or use intermediate
positions to decrease segment length.
50369, Calibration using stored offset failed
Description
Failed to calibrate the sensor using stored offset.
Consequences
The force control system is not calibrated. It is not possible to activate
force control.
Probable causes
Calibration using stored offset is only possible if a normal calibration
has been performed earlier.
50370, Transfer of data to SMB memory failed
Description
Transfer of data from cabinet to SMB memory not allowed or
interrupted for mechanical unit arg due to disconnect of SMB.
Probable causes
SMB was disconnected before or during calibration or manual move
of data to SMB memory.
Recommended actions
Retry to calibrate or manually move data from cabinet to SMB
memory when SMB is reconnected.
50371, The programmed speed is too high
Description
The speed change functionality is only allowed for low programmed
speed.
Probable causes
The programmed speed is too high.
Recommended actions
Lower the programmed speed or modify the configuration parameters.
50372, Contact force too high
Description
The contact force is too high during the recover phase.
Probable causes
The programmed path in the recover function causes too high contact
forces.
Recommended actions
Check and modify the recover function or allow higher contact force.
50373, Too high Event Preset Time
Description
The configured Event Preset Time is too high. The maximum value is
arg .
Consequences
The Event Preset Time is reduced to the maximum value.
Probable causes
This error can occur for robots with a low Dynamic Resolution and a
high Event Preset Time. The reason is a computer memory limitation.
Recommended actions
Reduce the Event Preset Time in the configuration parameters to a
value no higher than arg .
50375, Dynamic load too high
Description
Required torque for robot arg axis arg too high.
Recommended actions
If weaving one of these actions may help:
- Reduce weave frequency or weave amplitude for this movement.
- Reduce process speed.
- Increase zone size if small zones are used.
- Increase distance between programmed points if they are close.
If Conveyor Tracking: Reduce conveyor speed.
50376, Geometric interpolation failed.
Description
Task. arg
Failed to interpolate the desired geometry.
Program Ref. arg
(Internal code: arg )
Recommended actions
Increase the zone size, move the programmed point, change tool
orientation or change interpolation method.
6 Trouble shooting by Event log
306
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50377, Only allowed in position control
Description
The instruction is only allowed when the robot is in position control
mode.
Probable causes
The error depends on calling an instruction that is only allowed to be
used in position control while in force control mode.
Recommended actions
Call the instruction only when the robot is in position control mode.
50378, Error in FCSetMaxForceChangeTune
Description
Incorrect value of the parameter ForceChange in instruction
FCSetMaxForceChangeTune.
Consequences
The program will stop.
Probable causes
The parameter must be set larger than zero and less than the configured
value.
Recommended actions
Change the parameter value.
50379, Active mechanical units have changed
Description
When calling RestoPath all mechanical units have to be in the same
active state as when StorePath was called.
Recommended actions
Make sure that all mechanical units that were active when calling
StorePath still are and that no other mechanical unit is active when
calling RestoPath.
50380, Checksum error
Description
Data in SMB memory for mechanical unit arg has erroneous
checksum.
Probable causes
New SMB-board. System shut down before data save finished.
Recommended actions
- Load new configuration files.
50381, Speed too low.
Description
Task. arg
The speed is too low (numerical resolution).
Program Ref. arg
Recommended actions
Increase the programmed speed.
Check also the other synchronized tasks in a multimove application.
50382, Weave pattern error
Description
Calculation of weave pattern has failed due to an internal error.
Recommended actions
Try to restart.
50383, Cartesian Soft Servo configuration error
Description
Some configuration parameter for Cartesian Soft Servo is not valid.
Consequences
The system will not start.
Probable causes
Some configuration parameter has been set to a
value that is not allowed.
Recommended actions
Verify that any modifed parameter are within allowed limits.
50384, Cartesian Soft Servo quaternions invalid
Description
The quaternions of the tool, workobject or the argument RefOrient in
the CSSAct instruction are invalid.
Consequences
Cartesian Soft Servo will not activate.
Recommended actions
Check the quaternions of the tool, workobject or the argument
RefOrient in the CSSAct instruction.
50385, Cartesian Soft Servo activation failed
Description
The instruction CSSAct failed.
Probable causes
Cartesian Soft Servo already active.
Recommended actions
Cartesian Soft Servo needs to be deativated before it can be activated.
50386, Cartesian Soft Servo offset activation
failed
Description
The instruction CSSForceOffsetAct failed.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 308
|
6 Trouble shooting by Event log
305
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50367, Sensor Sync machine stop
Description
Sensor Sync device arg has set machine stop signal arg .
Recommended actions
Do not restart robot before machine is open. Sensor sync is disabled.
50368, Too Short distance between equidistant
events
Description
The events are too close together. End of internal resources (events).
Task: arg
Program Ref. arg
Recommended actions
Increase the distance between equidistant events or use intermediate
positions to decrease segment length.
50369, Calibration using stored offset failed
Description
Failed to calibrate the sensor using stored offset.
Consequences
The force control system is not calibrated. It is not possible to activate
force control.
Probable causes
Calibration using stored offset is only possible if a normal calibration
has been performed earlier.
50370, Transfer of data to SMB memory failed
Description
Transfer of data from cabinet to SMB memory not allowed or
interrupted for mechanical unit arg due to disconnect of SMB.
Probable causes
SMB was disconnected before or during calibration or manual move
of data to SMB memory.
Recommended actions
Retry to calibrate or manually move data from cabinet to SMB
memory when SMB is reconnected.
50371, The programmed speed is too high
Description
The speed change functionality is only allowed for low programmed
speed.
Probable causes
The programmed speed is too high.
Recommended actions
Lower the programmed speed or modify the configuration parameters.
50372, Contact force too high
Description
The contact force is too high during the recover phase.
Probable causes
The programmed path in the recover function causes too high contact
forces.
Recommended actions
Check and modify the recover function or allow higher contact force.
50373, Too high Event Preset Time
Description
The configured Event Preset Time is too high. The maximum value is
arg .
Consequences
The Event Preset Time is reduced to the maximum value.
Probable causes
This error can occur for robots with a low Dynamic Resolution and a
high Event Preset Time. The reason is a computer memory limitation.
Recommended actions
Reduce the Event Preset Time in the configuration parameters to a
value no higher than arg .
50375, Dynamic load too high
Description
Required torque for robot arg axis arg too high.
Recommended actions
If weaving one of these actions may help:
- Reduce weave frequency or weave amplitude for this movement.
- Reduce process speed.
- Increase zone size if small zones are used.
- Increase distance between programmed points if they are close.
If Conveyor Tracking: Reduce conveyor speed.
50376, Geometric interpolation failed.
Description
Task. arg
Failed to interpolate the desired geometry.
Program Ref. arg
(Internal code: arg )
Recommended actions
Increase the zone size, move the programmed point, change tool
orientation or change interpolation method.
6 Trouble shooting by Event log
306
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50377, Only allowed in position control
Description
The instruction is only allowed when the robot is in position control
mode.
Probable causes
The error depends on calling an instruction that is only allowed to be
used in position control while in force control mode.
Recommended actions
Call the instruction only when the robot is in position control mode.
50378, Error in FCSetMaxForceChangeTune
Description
Incorrect value of the parameter ForceChange in instruction
FCSetMaxForceChangeTune.
Consequences
The program will stop.
Probable causes
The parameter must be set larger than zero and less than the configured
value.
Recommended actions
Change the parameter value.
50379, Active mechanical units have changed
Description
When calling RestoPath all mechanical units have to be in the same
active state as when StorePath was called.
Recommended actions
Make sure that all mechanical units that were active when calling
StorePath still are and that no other mechanical unit is active when
calling RestoPath.
50380, Checksum error
Description
Data in SMB memory for mechanical unit arg has erroneous
checksum.
Probable causes
New SMB-board. System shut down before data save finished.
Recommended actions
- Load new configuration files.
50381, Speed too low.
Description
Task. arg
The speed is too low (numerical resolution).
Program Ref. arg
Recommended actions
Increase the programmed speed.
Check also the other synchronized tasks in a multimove application.
50382, Weave pattern error
Description
Calculation of weave pattern has failed due to an internal error.
Recommended actions
Try to restart.
50383, Cartesian Soft Servo configuration error
Description
Some configuration parameter for Cartesian Soft Servo is not valid.
Consequences
The system will not start.
Probable causes
Some configuration parameter has been set to a
value that is not allowed.
Recommended actions
Verify that any modifed parameter are within allowed limits.
50384, Cartesian Soft Servo quaternions invalid
Description
The quaternions of the tool, workobject or the argument RefOrient in
the CSSAct instruction are invalid.
Consequences
Cartesian Soft Servo will not activate.
Recommended actions
Check the quaternions of the tool, workobject or the argument
RefOrient in the CSSAct instruction.
50385, Cartesian Soft Servo activation failed
Description
The instruction CSSAct failed.
Probable causes
Cartesian Soft Servo already active.
Recommended actions
Cartesian Soft Servo needs to be deativated before it can be activated.
50386, Cartesian Soft Servo offset activation
failed
Description
The instruction CSSForceOffsetAct failed.
6 Trouble shooting by Event log
307
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
Force offset was not activated.
Probable causes
CSSForceOffsetAct instruction is only allowed when Cartesian Soft
Servo is active.
Recommended actions
Activate Cartesian Soft Servo with the instruction CSSAct before
using the instruction CSSForceOffsetAct .
50387, Cartesian Soft Servo close to unstable
Description
Cartesian Soft Servo is close to unstable.
Consequences
The robot is halted as a security measure.
Probable causes
The system damping is too low.
Recommended actions
Increase the value of Damping in the CSSAct instruction or if that does
not help increase the value of the configuration parameter Damping
Stability Limit.
50388, Cartesian Soft Servo position
supervision error
Description
The user defined position supervision in Cartesian Soft Servo mode
trigged.
Consequences
The robot halts.
Probable causes
The position error is larger than the allowed range specified in the
configuration.
Recommended actions
Increase the allowed position error in the configuration or modify the
program.
50389, Cartesian Soft Servo singularity
Description
The robot is too close to singularity which effects the Cartesian Soft
Servo behaviour.
Consequences
The robot behaviour will be different from specified.
Recommended actions
Modify the program to avoid the singularity.
50390, Cartesian Soft Servo speed supervision
Description
The user defined speed supervision in Cartesian Soft Servo mode
trigged.
Consequences
The robot halts.
Probable causes
The speed error is larger than the allowed range specified in the
configuration.
Recommended actions
Increase the allowed speed error in the configuration or modify the
program.
50391, Cartesian Soft Servo movement not
allowed
Description
Jogging or a programmed movement has been detected.
Consequences
The ordered movement is ignored.
Recommended actions
Movement during Cartesian Soft Servo is only allowed if the switch
AllowMove has been used in the CSSAct instruction.
50392, SafeMove communication error
Description
Communication with SafeMove controller on drive module arg has
failed.
Consequences
Brake tests can not be done.
Recommended actions
Check if SafeMove hardware is connected.
50393, Force offset applied in non-soft direction
Description
The force-offset direction in CSSForceOffsetAct is not the same as the
soft direction specified by CSSAct.
Consequences
The robot will not become easier to push in the soft direction. There
can also be position deviations from the programmed path in the non-
soft directions.
Recommended actions
Make sure the direction given in CSSForceOffsetAct is compatible
with the direction given in CSSAct.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 309
|
6 Trouble shooting by Event log
306
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50377, Only allowed in position control
Description
The instruction is only allowed when the robot is in position control
mode.
Probable causes
The error depends on calling an instruction that is only allowed to be
used in position control while in force control mode.
Recommended actions
Call the instruction only when the robot is in position control mode.
50378, Error in FCSetMaxForceChangeTune
Description
Incorrect value of the parameter ForceChange in instruction
FCSetMaxForceChangeTune.
Consequences
The program will stop.
Probable causes
The parameter must be set larger than zero and less than the configured
value.
Recommended actions
Change the parameter value.
50379, Active mechanical units have changed
Description
When calling RestoPath all mechanical units have to be in the same
active state as when StorePath was called.
Recommended actions
Make sure that all mechanical units that were active when calling
StorePath still are and that no other mechanical unit is active when
calling RestoPath.
50380, Checksum error
Description
Data in SMB memory for mechanical unit arg has erroneous
checksum.
Probable causes
New SMB-board. System shut down before data save finished.
Recommended actions
- Load new configuration files.
50381, Speed too low.
Description
Task. arg
The speed is too low (numerical resolution).
Program Ref. arg
Recommended actions
Increase the programmed speed.
Check also the other synchronized tasks in a multimove application.
50382, Weave pattern error
Description
Calculation of weave pattern has failed due to an internal error.
Recommended actions
Try to restart.
50383, Cartesian Soft Servo configuration error
Description
Some configuration parameter for Cartesian Soft Servo is not valid.
Consequences
The system will not start.
Probable causes
Some configuration parameter has been set to a
value that is not allowed.
Recommended actions
Verify that any modifed parameter are within allowed limits.
50384, Cartesian Soft Servo quaternions invalid
Description
The quaternions of the tool, workobject or the argument RefOrient in
the CSSAct instruction are invalid.
Consequences
Cartesian Soft Servo will not activate.
Recommended actions
Check the quaternions of the tool, workobject or the argument
RefOrient in the CSSAct instruction.
50385, Cartesian Soft Servo activation failed
Description
The instruction CSSAct failed.
Probable causes
Cartesian Soft Servo already active.
Recommended actions
Cartesian Soft Servo needs to be deativated before it can be activated.
50386, Cartesian Soft Servo offset activation
failed
Description
The instruction CSSForceOffsetAct failed.
6 Trouble shooting by Event log
307
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
Force offset was not activated.
Probable causes
CSSForceOffsetAct instruction is only allowed when Cartesian Soft
Servo is active.
Recommended actions
Activate Cartesian Soft Servo with the instruction CSSAct before
using the instruction CSSForceOffsetAct .
50387, Cartesian Soft Servo close to unstable
Description
Cartesian Soft Servo is close to unstable.
Consequences
The robot is halted as a security measure.
Probable causes
The system damping is too low.
Recommended actions
Increase the value of Damping in the CSSAct instruction or if that does
not help increase the value of the configuration parameter Damping
Stability Limit.
50388, Cartesian Soft Servo position
supervision error
Description
The user defined position supervision in Cartesian Soft Servo mode
trigged.
Consequences
The robot halts.
Probable causes
The position error is larger than the allowed range specified in the
configuration.
Recommended actions
Increase the allowed position error in the configuration or modify the
program.
50389, Cartesian Soft Servo singularity
Description
The robot is too close to singularity which effects the Cartesian Soft
Servo behaviour.
Consequences
The robot behaviour will be different from specified.
Recommended actions
Modify the program to avoid the singularity.
50390, Cartesian Soft Servo speed supervision
Description
The user defined speed supervision in Cartesian Soft Servo mode
trigged.
Consequences
The robot halts.
Probable causes
The speed error is larger than the allowed range specified in the
configuration.
Recommended actions
Increase the allowed speed error in the configuration or modify the
program.
50391, Cartesian Soft Servo movement not
allowed
Description
Jogging or a programmed movement has been detected.
Consequences
The ordered movement is ignored.
Recommended actions
Movement during Cartesian Soft Servo is only allowed if the switch
AllowMove has been used in the CSSAct instruction.
50392, SafeMove communication error
Description
Communication with SafeMove controller on drive module arg has
failed.
Consequences
Brake tests can not be done.
Recommended actions
Check if SafeMove hardware is connected.
50393, Force offset applied in non-soft direction
Description
The force-offset direction in CSSForceOffsetAct is not the same as the
soft direction specified by CSSAct.
Consequences
The robot will not become easier to push in the soft direction. There
can also be position deviations from the programmed path in the non-
soft directions.
Recommended actions
Make sure the direction given in CSSForceOffsetAct is compatible
with the direction given in CSSAct.
6 Trouble shooting by Event log
308
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50394, Unit out of position
Description
The Robot arg is semi coordinated to Unit arg and the Unit must stand
in a fine point when the Robot is moving in the user frame.
Consequences
The restart will be interrupted.
Recommended actions
Use WaitSyncTask to separate the semi coordinated move from other
moves, SyncMoveOn, SyncMoveResume and SyncMoveOff. After a
SyncMoveOff the Unit must also be moved (MoveL or MoveExtJ) to
a finepoint to make regain possible after a stop during the semi
coordinated move. If the programmed position of the Unit is moved by
modpos the Robot program must be reset by moving the PP to be able
to restart the program. Step also the unit to the new position to make
stepping of the robot possible.
50395, Too long programmed move
Description
Task: arg
This move is too long for the programmed speed. The numerical
resolution in the path planning is not enough.
Program Ref. arg
Consequences
The speed will be increased i.e. higher than the programmed speed.
Recommended actions
Insert intermediate points or increase the speed.
50396, Default FC force supervision error
Description
The default force supervision has trigged because the programmed or
measured external forces are larger than the safety limit for the robot
type.
Consequences
The robot will stop.
Recommended actions
Modify the program to decrease the total external force acting on the
robot.
50397, Path frame rotation speed error
Description
The rotation speed of the path frame is too high when using FC
Machining with ForceFrameRef set to FC_REFFRAME_PATH.
Consequences
The robot will stop.
Recommended actions
Reduce programmed speed, increase corner zones, or decrease the
distance between the programmed path and the surface.
50398, AbsAcc circle begins with a frame
change
Description
Task: arg
When having the AbsAcc option, MoveC instructions that are
coordinated to another robot must use the same tool and work object
as the previous move instruction.
Consequences
The robot will stop.
Recommended actions
Change the move instruction before arg so that they both use the same
frames. Alternatively, add a (redundant) MoveL to the start point of the
circle arc, using the same frames as the MoveC instruction.
50399, AbsAcc circle is first movement
instruction
Description
Task: arg
When having the AbsAcc option, MoveC cannot be the first
movement instruction.
Consequences
The robot will stop.
Recommended actions
Add a movement instruction before arg , using the same tool and
frames.
50400, Manipulator configuration error
Description
The parameter disconnect_link_at_deactivate for
MEASUREMENT_CHANNEL was inconsistent for
measurement_link arg . All channels on the same link have to have the
same setting for this parameter.
Recommended actions
Check the configuration file - cold start the system with correct
parameters.
50401, Startup synchronization failed
Description
The system relay ' arg ' is defined but no response was received during
the startup(waited for arg minutes).
Recommended actions
Make sure that the in_signal of the relay is configured and connected
and startup all synchronized systems simultaneously.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 310
|
6 Trouble shooting by Event log
307
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
Force offset was not activated.
Probable causes
CSSForceOffsetAct instruction is only allowed when Cartesian Soft
Servo is active.
Recommended actions
Activate Cartesian Soft Servo with the instruction CSSAct before
using the instruction CSSForceOffsetAct .
50387, Cartesian Soft Servo close to unstable
Description
Cartesian Soft Servo is close to unstable.
Consequences
The robot is halted as a security measure.
Probable causes
The system damping is too low.
Recommended actions
Increase the value of Damping in the CSSAct instruction or if that does
not help increase the value of the configuration parameter Damping
Stability Limit.
50388, Cartesian Soft Servo position
supervision error
Description
The user defined position supervision in Cartesian Soft Servo mode
trigged.
Consequences
The robot halts.
Probable causes
The position error is larger than the allowed range specified in the
configuration.
Recommended actions
Increase the allowed position error in the configuration or modify the
program.
50389, Cartesian Soft Servo singularity
Description
The robot is too close to singularity which effects the Cartesian Soft
Servo behaviour.
Consequences
The robot behaviour will be different from specified.
Recommended actions
Modify the program to avoid the singularity.
50390, Cartesian Soft Servo speed supervision
Description
The user defined speed supervision in Cartesian Soft Servo mode
trigged.
Consequences
The robot halts.
Probable causes
The speed error is larger than the allowed range specified in the
configuration.
Recommended actions
Increase the allowed speed error in the configuration or modify the
program.
50391, Cartesian Soft Servo movement not
allowed
Description
Jogging or a programmed movement has been detected.
Consequences
The ordered movement is ignored.
Recommended actions
Movement during Cartesian Soft Servo is only allowed if the switch
AllowMove has been used in the CSSAct instruction.
50392, SafeMove communication error
Description
Communication with SafeMove controller on drive module arg has
failed.
Consequences
Brake tests can not be done.
Recommended actions
Check if SafeMove hardware is connected.
50393, Force offset applied in non-soft direction
Description
The force-offset direction in CSSForceOffsetAct is not the same as the
soft direction specified by CSSAct.
Consequences
The robot will not become easier to push in the soft direction. There
can also be position deviations from the programmed path in the non-
soft directions.
Recommended actions
Make sure the direction given in CSSForceOffsetAct is compatible
with the direction given in CSSAct.
6 Trouble shooting by Event log
308
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50394, Unit out of position
Description
The Robot arg is semi coordinated to Unit arg and the Unit must stand
in a fine point when the Robot is moving in the user frame.
Consequences
The restart will be interrupted.
Recommended actions
Use WaitSyncTask to separate the semi coordinated move from other
moves, SyncMoveOn, SyncMoveResume and SyncMoveOff. After a
SyncMoveOff the Unit must also be moved (MoveL or MoveExtJ) to
a finepoint to make regain possible after a stop during the semi
coordinated move. If the programmed position of the Unit is moved by
modpos the Robot program must be reset by moving the PP to be able
to restart the program. Step also the unit to the new position to make
stepping of the robot possible.
50395, Too long programmed move
Description
Task: arg
This move is too long for the programmed speed. The numerical
resolution in the path planning is not enough.
Program Ref. arg
Consequences
The speed will be increased i.e. higher than the programmed speed.
Recommended actions
Insert intermediate points or increase the speed.
50396, Default FC force supervision error
Description
The default force supervision has trigged because the programmed or
measured external forces are larger than the safety limit for the robot
type.
Consequences
The robot will stop.
Recommended actions
Modify the program to decrease the total external force acting on the
robot.
50397, Path frame rotation speed error
Description
The rotation speed of the path frame is too high when using FC
Machining with ForceFrameRef set to FC_REFFRAME_PATH.
Consequences
The robot will stop.
Recommended actions
Reduce programmed speed, increase corner zones, or decrease the
distance between the programmed path and the surface.
50398, AbsAcc circle begins with a frame
change
Description
Task: arg
When having the AbsAcc option, MoveC instructions that are
coordinated to another robot must use the same tool and work object
as the previous move instruction.
Consequences
The robot will stop.
Recommended actions
Change the move instruction before arg so that they both use the same
frames. Alternatively, add a (redundant) MoveL to the start point of the
circle arc, using the same frames as the MoveC instruction.
50399, AbsAcc circle is first movement
instruction
Description
Task: arg
When having the AbsAcc option, MoveC cannot be the first
movement instruction.
Consequences
The robot will stop.
Recommended actions
Add a movement instruction before arg , using the same tool and
frames.
50400, Manipulator configuration error
Description
The parameter disconnect_link_at_deactivate for
MEASUREMENT_CHANNEL was inconsistent for
measurement_link arg . All channels on the same link have to have the
same setting for this parameter.
Recommended actions
Check the configuration file - cold start the system with correct
parameters.
50401, Startup synchronization failed
Description
The system relay ' arg ' is defined but no response was received during
the startup(waited for arg minutes).
Recommended actions
Make sure that the in_signal of the relay is configured and connected
and startup all synchronized systems simultaneously.
6 Trouble shooting by Event log
309
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50402, Correction is not ended in a finepoint
Description
Task: arg
The last move instruction with correction specified has to be a
finepoint.
Program Ref. arg
Recommended actions
Change the zone parameter to fine.
50403, AW board not connected
Description
During startup, no communication was established with unit < arg > on
bus < arg >.
Consequences
It is not possible to access the unit or signals on the unit, since it is
currently not communicating with the controller.
Probable causes
The unit is either not connected to the system, or it is connected, but
has been assigned the wrong address.
Recommended actions
1. Make sure all unit addresses match the configuration.
2. Make sure all addresses are unique, and not used by more than one
unit.
3. Change the address and/or connect the missing unit.
4. If you changed the address, the power supply to the unit must be
cycled (switched OFF and then back ON), to make sure the address has
been changed.
50404, Additional axis movement during Wrist
Interpolation
Description
Task: arg
Program Ref. arg
An additional axis is programmed to move during Wrist Interpolation.
Consequences
The task execution will stop.
Recommended actions
Make sure that no additional axis is programmed to move while doing
Wrist Interpolation.
50405, Coordinated movement during Wrist
Interpolation
Description
Task: arg
Program Ref. arg
Attempt to do Wrist Interpolation against a moving frame.
Consequences
The task execution will stop.
Recommended actions
Remove movement coordination while doing the Wrist Interpolation.
50406, Wrist Interpolation point not on circle
plane
Description
Task: arg
Program Ref. arg
The target arg is not on the circle plane. The deviation is arg mm.
p1 = starting point
p2 = circle point
p3 = end point
Consequences
For a cutting process, the cut hole will not be circular.
Recommended actions
If a circular arc is intended, then change the corresponding target so
that it is on the circle plane.
50407, Wrist axis locked
Description
Task: arg
Program Ref. arg
Cannot do Wrist Interpolation using arg because axis arg is locked.
Consequences
The task execution will stop.
Recommended actions
Change to another wrist axis combination that does not involve the
locked axis. Note that the robot must have at least two movable wrist
axes to do Wrist Interpolation.
50408, Wrist joint limit
Description
Task: arg
Program Ref. arg
Cannot do Wrist Interpolation because robot axis arg will violate a
joint limit.
Consequences
The task execution will stop.
Recommended actions
Choose another robot configuration or another wrist axis combination.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 311
|
6 Trouble shooting by Event log
308
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50394, Unit out of position
Description
The Robot arg is semi coordinated to Unit arg and the Unit must stand
in a fine point when the Robot is moving in the user frame.
Consequences
The restart will be interrupted.
Recommended actions
Use WaitSyncTask to separate the semi coordinated move from other
moves, SyncMoveOn, SyncMoveResume and SyncMoveOff. After a
SyncMoveOff the Unit must also be moved (MoveL or MoveExtJ) to
a finepoint to make regain possible after a stop during the semi
coordinated move. If the programmed position of the Unit is moved by
modpos the Robot program must be reset by moving the PP to be able
to restart the program. Step also the unit to the new position to make
stepping of the robot possible.
50395, Too long programmed move
Description
Task: arg
This move is too long for the programmed speed. The numerical
resolution in the path planning is not enough.
Program Ref. arg
Consequences
The speed will be increased i.e. higher than the programmed speed.
Recommended actions
Insert intermediate points or increase the speed.
50396, Default FC force supervision error
Description
The default force supervision has trigged because the programmed or
measured external forces are larger than the safety limit for the robot
type.
Consequences
The robot will stop.
Recommended actions
Modify the program to decrease the total external force acting on the
robot.
50397, Path frame rotation speed error
Description
The rotation speed of the path frame is too high when using FC
Machining with ForceFrameRef set to FC_REFFRAME_PATH.
Consequences
The robot will stop.
Recommended actions
Reduce programmed speed, increase corner zones, or decrease the
distance between the programmed path and the surface.
50398, AbsAcc circle begins with a frame
change
Description
Task: arg
When having the AbsAcc option, MoveC instructions that are
coordinated to another robot must use the same tool and work object
as the previous move instruction.
Consequences
The robot will stop.
Recommended actions
Change the move instruction before arg so that they both use the same
frames. Alternatively, add a (redundant) MoveL to the start point of the
circle arc, using the same frames as the MoveC instruction.
50399, AbsAcc circle is first movement
instruction
Description
Task: arg
When having the AbsAcc option, MoveC cannot be the first
movement instruction.
Consequences
The robot will stop.
Recommended actions
Add a movement instruction before arg , using the same tool and
frames.
50400, Manipulator configuration error
Description
The parameter disconnect_link_at_deactivate for
MEASUREMENT_CHANNEL was inconsistent for
measurement_link arg . All channels on the same link have to have the
same setting for this parameter.
Recommended actions
Check the configuration file - cold start the system with correct
parameters.
50401, Startup synchronization failed
Description
The system relay ' arg ' is defined but no response was received during
the startup(waited for arg minutes).
Recommended actions
Make sure that the in_signal of the relay is configured and connected
and startup all synchronized systems simultaneously.
6 Trouble shooting by Event log
309
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50402, Correction is not ended in a finepoint
Description
Task: arg
The last move instruction with correction specified has to be a
finepoint.
Program Ref. arg
Recommended actions
Change the zone parameter to fine.
50403, AW board not connected
Description
During startup, no communication was established with unit < arg > on
bus < arg >.
Consequences
It is not possible to access the unit or signals on the unit, since it is
currently not communicating with the controller.
Probable causes
The unit is either not connected to the system, or it is connected, but
has been assigned the wrong address.
Recommended actions
1. Make sure all unit addresses match the configuration.
2. Make sure all addresses are unique, and not used by more than one
unit.
3. Change the address and/or connect the missing unit.
4. If you changed the address, the power supply to the unit must be
cycled (switched OFF and then back ON), to make sure the address has
been changed.
50404, Additional axis movement during Wrist
Interpolation
Description
Task: arg
Program Ref. arg
An additional axis is programmed to move during Wrist Interpolation.
Consequences
The task execution will stop.
Recommended actions
Make sure that no additional axis is programmed to move while doing
Wrist Interpolation.
50405, Coordinated movement during Wrist
Interpolation
Description
Task: arg
Program Ref. arg
Attempt to do Wrist Interpolation against a moving frame.
Consequences
The task execution will stop.
Recommended actions
Remove movement coordination while doing the Wrist Interpolation.
50406, Wrist Interpolation point not on circle
plane
Description
Task: arg
Program Ref. arg
The target arg is not on the circle plane. The deviation is arg mm.
p1 = starting point
p2 = circle point
p3 = end point
Consequences
For a cutting process, the cut hole will not be circular.
Recommended actions
If a circular arc is intended, then change the corresponding target so
that it is on the circle plane.
50407, Wrist axis locked
Description
Task: arg
Program Ref. arg
Cannot do Wrist Interpolation using arg because axis arg is locked.
Consequences
The task execution will stop.
Recommended actions
Change to another wrist axis combination that does not involve the
locked axis. Note that the robot must have at least two movable wrist
axes to do Wrist Interpolation.
50408, Wrist joint limit
Description
Task: arg
Program Ref. arg
Cannot do Wrist Interpolation because robot axis arg will violate a
joint limit.
Consequences
The task execution will stop.
Recommended actions
Choose another robot configuration or another wrist axis combination.
6 Trouble shooting by Event log
310
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50409, Wrist Interpolation not possible
Description
Task: arg
Program Ref. arg
The programmed Wrist Interpolation is not kinematically possible
using arg .
Consequences
The task execution will stop.
Recommended actions
Choose another robot configuration or another wrist axis combination.
Possible wrist axis combinations are: Wrist45, Wrist46, and Wrist56.
50410, Collinear targets in wrong order
Description
Task: arg
Program Ref. arg
The programmed targets are collinear, but the end point is between the
start point and the circle point.
Consequences
The task execution will stop.
Recommended actions
If a straight line is intended, then let the circle point and the end point
swap places with each other.
50411, Maximum allowed programmed TCP
load exceeded
Description
The currently defined TCP load for robot arg exceeds the maximum
allowed load for the robot model.
Consequences
The robot will stop.
Probable causes
The combination of the current tool load and payload exceeds the
maximum load allowed for the robot model.
Recommended actions
Make sure that the total TCP load is inside the load diagram for the
robot.
50412, Error in speed change tuning instruction
Description
The speed change tuning instruction resulted in an error.
Consequences
The robot will stop.
Probable causes
The speed change tuning instruction was not allowed, or the
parameters given were invalid.
Recommended actions
Check the values for the parameter and tuning type, and make sure the
correct force control option is installed and configured correctly.
50413, Bleeder resistor overload error
Description
In drive module arg , the bleeder resistor connected to the rectifier
unit at drive unit position arg was overloaded.
Consequences
No operation will be possible until the bleeder resistor has cooled
down. The system goes to Motors Off state.
Probable causes
1) The user program may contain too much deceleration of the
manipulator's axes. This fault is more likely if the system contains
additional axes.
2) Bleeder resistor has wrong resistance.
3) Short circuit in motor cable between phase to phase or phase to
ground.
Recommended actions
1) Rewrite the user program to reduce the amount of hard
decelerations.
2) Disconnect the bleeder and check the cable and measure the bleeder
resistance. The expected resistance should be approximately arg ohms.
3) Verify that the motor cables has no short circuits internally or to
ground.
50414, Bleeder resistor overload warning
Description
In drive module arg , the bleeder resistor connected to the rectifier
unit at drive unit position arg is close to overload.
Consequences
Operation will be possible but system is close to a stopping error.
Probable causes
1) The user program may contain too much deceleration of the
manipulator's axes. This fault is more likely if the system contains
additional axes.
2) Bleeder resistor has wrong resistance.
3) Short circuit in motor cable between phase to phase or phase to
ground.
Recommended actions
1) Rewrite the user program to reduce the amount of hard
decelerations.
2) Disconnect the bleeder and check the cable and measure the bleeder
resistance. The expected resistance should be approximately arg ohms.
3) Verify that the motor cables has no short circuits internally or to
ground.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 312
|
6 Trouble shooting by Event log
309
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50402, Correction is not ended in a finepoint
Description
Task: arg
The last move instruction with correction specified has to be a
finepoint.
Program Ref. arg
Recommended actions
Change the zone parameter to fine.
50403, AW board not connected
Description
During startup, no communication was established with unit < arg > on
bus < arg >.
Consequences
It is not possible to access the unit or signals on the unit, since it is
currently not communicating with the controller.
Probable causes
The unit is either not connected to the system, or it is connected, but
has been assigned the wrong address.
Recommended actions
1. Make sure all unit addresses match the configuration.
2. Make sure all addresses are unique, and not used by more than one
unit.
3. Change the address and/or connect the missing unit.
4. If you changed the address, the power supply to the unit must be
cycled (switched OFF and then back ON), to make sure the address has
been changed.
50404, Additional axis movement during Wrist
Interpolation
Description
Task: arg
Program Ref. arg
An additional axis is programmed to move during Wrist Interpolation.
Consequences
The task execution will stop.
Recommended actions
Make sure that no additional axis is programmed to move while doing
Wrist Interpolation.
50405, Coordinated movement during Wrist
Interpolation
Description
Task: arg
Program Ref. arg
Attempt to do Wrist Interpolation against a moving frame.
Consequences
The task execution will stop.
Recommended actions
Remove movement coordination while doing the Wrist Interpolation.
50406, Wrist Interpolation point not on circle
plane
Description
Task: arg
Program Ref. arg
The target arg is not on the circle plane. The deviation is arg mm.
p1 = starting point
p2 = circle point
p3 = end point
Consequences
For a cutting process, the cut hole will not be circular.
Recommended actions
If a circular arc is intended, then change the corresponding target so
that it is on the circle plane.
50407, Wrist axis locked
Description
Task: arg
Program Ref. arg
Cannot do Wrist Interpolation using arg because axis arg is locked.
Consequences
The task execution will stop.
Recommended actions
Change to another wrist axis combination that does not involve the
locked axis. Note that the robot must have at least two movable wrist
axes to do Wrist Interpolation.
50408, Wrist joint limit
Description
Task: arg
Program Ref. arg
Cannot do Wrist Interpolation because robot axis arg will violate a
joint limit.
Consequences
The task execution will stop.
Recommended actions
Choose another robot configuration or another wrist axis combination.
6 Trouble shooting by Event log
310
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50409, Wrist Interpolation not possible
Description
Task: arg
Program Ref. arg
The programmed Wrist Interpolation is not kinematically possible
using arg .
Consequences
The task execution will stop.
Recommended actions
Choose another robot configuration or another wrist axis combination.
Possible wrist axis combinations are: Wrist45, Wrist46, and Wrist56.
50410, Collinear targets in wrong order
Description
Task: arg
Program Ref. arg
The programmed targets are collinear, but the end point is between the
start point and the circle point.
Consequences
The task execution will stop.
Recommended actions
If a straight line is intended, then let the circle point and the end point
swap places with each other.
50411, Maximum allowed programmed TCP
load exceeded
Description
The currently defined TCP load for robot arg exceeds the maximum
allowed load for the robot model.
Consequences
The robot will stop.
Probable causes
The combination of the current tool load and payload exceeds the
maximum load allowed for the robot model.
Recommended actions
Make sure that the total TCP load is inside the load diagram for the
robot.
50412, Error in speed change tuning instruction
Description
The speed change tuning instruction resulted in an error.
Consequences
The robot will stop.
Probable causes
The speed change tuning instruction was not allowed, or the
parameters given were invalid.
Recommended actions
Check the values for the parameter and tuning type, and make sure the
correct force control option is installed and configured correctly.
50413, Bleeder resistor overload error
Description
In drive module arg , the bleeder resistor connected to the rectifier
unit at drive unit position arg was overloaded.
Consequences
No operation will be possible until the bleeder resistor has cooled
down. The system goes to Motors Off state.
Probable causes
1) The user program may contain too much deceleration of the
manipulator's axes. This fault is more likely if the system contains
additional axes.
2) Bleeder resistor has wrong resistance.
3) Short circuit in motor cable between phase to phase or phase to
ground.
Recommended actions
1) Rewrite the user program to reduce the amount of hard
decelerations.
2) Disconnect the bleeder and check the cable and measure the bleeder
resistance. The expected resistance should be approximately arg ohms.
3) Verify that the motor cables has no short circuits internally or to
ground.
50414, Bleeder resistor overload warning
Description
In drive module arg , the bleeder resistor connected to the rectifier
unit at drive unit position arg is close to overload.
Consequences
Operation will be possible but system is close to a stopping error.
Probable causes
1) The user program may contain too much deceleration of the
manipulator's axes. This fault is more likely if the system contains
additional axes.
2) Bleeder resistor has wrong resistance.
3) Short circuit in motor cable between phase to phase or phase to
ground.
Recommended actions
1) Rewrite the user program to reduce the amount of hard
decelerations.
2) Disconnect the bleeder and check the cable and measure the bleeder
resistance. The expected resistance should be approximately arg ohms.
3) Verify that the motor cables has no short circuits internally or to
ground.
6 Trouble shooting by Event log
311
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50415, Motor temperature error
Description
Motor temperature for joint arg is too high.
Consequences
It is not possible to continue until the motor has cooled down. The
system goes to Motors Off state.
Probable causes
The user program may contain too much hard acceleration and
deceleration of the joint. Gravity torque or external forces for the joint
can also be too high.
Recommended actions
Rewrite the user program to reduce the motor utilization.
50416, Motor temperature warning
Description
The motor temperature for joint arg is close to maximum value.
Consequences
It is possible to continue but the margin to maximum allowed
temperature is too low to sustain long term operation.
Probable causes
The user program may contain too much hard acceleration and hard
deceleration of the joint. The gravity torque or external forces for the
joint can also be too high.
Recommended actions
Rewrite the user program to reduce the motor utilization.
50417, Drive unit overload error
Description
The drive unit for joint arg has reached a too high temperature level.
The joint is connected to drive module arg with the drive unit at unit
position arg and node arg .
Consequences
No operation will be possible until the drive has cooled down. The
system goes to Motors Off state.
Probable causes
1) The joint may be running with a too high torque for extended
periods of time.
2) Short circuit in the manipulator using long motor cables.
Recommended actions
1) If possible, rewrite the user program to reduce the amount of hard
acceleration and hard deceleration.
2) Reduce the static torque due to gravity or external forces.
3) Check for short circuit in the motor cable or in the motor.
4) Check for other hardware eventlogs.
50418, Drive unit overload warning
Description
The drive unit for joint arg , connected to drive module arg with the
drive unit at unit position arg and node arg is approaching a too high
temperature level.
Consequences
It is possible to continue but margin to max temperature is too low for
long term operation.
Probable causes
1) The joint may be running with a too high torque for extended
periods of time.
2) Short circuit in the manipulator using long motor cables.
Recommended actions
1) If possible, rewrite the user program to reduce the amount of hard
acceleration and hard deceleration.
2) Reduce the static torque due to gravity or external forces.
3) Check for short circuit in the motor cable or in the motor.
4) Check for other hardware eventlogs.
50419, Common base_frame error
Description
Task: arg
The base_frame is moved by another task than the robot and could not
be solved, reason arg :
1 SingArea\Wrist not supported with MoveC.
2 The base_frame must be moved by first synchronized motion_group.
3 Only one common base_frame can be handled.
4 Absacc not supported with MoveC.
5 The common base_frame can only be solved in synchronized move.
Program Ref. arg
Recommended actions
1 Use SingArea\Off. The CirPathMode can also be used.
2,3 Check SYS.cfg and MOC.cfg.
4 Use MoveL or remove absacc.
5 Use MoveAbsJ.
50420, IndCnv Mechanical Unit Error
Description
The mechanical unit arg is not correctly configured for IndCnv
functionality.
Consequences
Program execution is stopped.
Probable causes
The mechanical unit arg consists of more than one single.
The single connected to arg is not of type FREE_ROT.
The single connected to arg is not defined as an Indexing Move single.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 313
|
6 Trouble shooting by Event log
310
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50409, Wrist Interpolation not possible
Description
Task: arg
Program Ref. arg
The programmed Wrist Interpolation is not kinematically possible
using arg .
Consequences
The task execution will stop.
Recommended actions
Choose another robot configuration or another wrist axis combination.
Possible wrist axis combinations are: Wrist45, Wrist46, and Wrist56.
50410, Collinear targets in wrong order
Description
Task: arg
Program Ref. arg
The programmed targets are collinear, but the end point is between the
start point and the circle point.
Consequences
The task execution will stop.
Recommended actions
If a straight line is intended, then let the circle point and the end point
swap places with each other.
50411, Maximum allowed programmed TCP
load exceeded
Description
The currently defined TCP load for robot arg exceeds the maximum
allowed load for the robot model.
Consequences
The robot will stop.
Probable causes
The combination of the current tool load and payload exceeds the
maximum load allowed for the robot model.
Recommended actions
Make sure that the total TCP load is inside the load diagram for the
robot.
50412, Error in speed change tuning instruction
Description
The speed change tuning instruction resulted in an error.
Consequences
The robot will stop.
Probable causes
The speed change tuning instruction was not allowed, or the
parameters given were invalid.
Recommended actions
Check the values for the parameter and tuning type, and make sure the
correct force control option is installed and configured correctly.
50413, Bleeder resistor overload error
Description
In drive module arg , the bleeder resistor connected to the rectifier
unit at drive unit position arg was overloaded.
Consequences
No operation will be possible until the bleeder resistor has cooled
down. The system goes to Motors Off state.
Probable causes
1) The user program may contain too much deceleration of the
manipulator's axes. This fault is more likely if the system contains
additional axes.
2) Bleeder resistor has wrong resistance.
3) Short circuit in motor cable between phase to phase or phase to
ground.
Recommended actions
1) Rewrite the user program to reduce the amount of hard
decelerations.
2) Disconnect the bleeder and check the cable and measure the bleeder
resistance. The expected resistance should be approximately arg ohms.
3) Verify that the motor cables has no short circuits internally or to
ground.
50414, Bleeder resistor overload warning
Description
In drive module arg , the bleeder resistor connected to the rectifier
unit at drive unit position arg is close to overload.
Consequences
Operation will be possible but system is close to a stopping error.
Probable causes
1) The user program may contain too much deceleration of the
manipulator's axes. This fault is more likely if the system contains
additional axes.
2) Bleeder resistor has wrong resistance.
3) Short circuit in motor cable between phase to phase or phase to
ground.
Recommended actions
1) Rewrite the user program to reduce the amount of hard
decelerations.
2) Disconnect the bleeder and check the cable and measure the bleeder
resistance. The expected resistance should be approximately arg ohms.
3) Verify that the motor cables has no short circuits internally or to
ground.
6 Trouble shooting by Event log
311
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50415, Motor temperature error
Description
Motor temperature for joint arg is too high.
Consequences
It is not possible to continue until the motor has cooled down. The
system goes to Motors Off state.
Probable causes
The user program may contain too much hard acceleration and
deceleration of the joint. Gravity torque or external forces for the joint
can also be too high.
Recommended actions
Rewrite the user program to reduce the motor utilization.
50416, Motor temperature warning
Description
The motor temperature for joint arg is close to maximum value.
Consequences
It is possible to continue but the margin to maximum allowed
temperature is too low to sustain long term operation.
Probable causes
The user program may contain too much hard acceleration and hard
deceleration of the joint. The gravity torque or external forces for the
joint can also be too high.
Recommended actions
Rewrite the user program to reduce the motor utilization.
50417, Drive unit overload error
Description
The drive unit for joint arg has reached a too high temperature level.
The joint is connected to drive module arg with the drive unit at unit
position arg and node arg .
Consequences
No operation will be possible until the drive has cooled down. The
system goes to Motors Off state.
Probable causes
1) The joint may be running with a too high torque for extended
periods of time.
2) Short circuit in the manipulator using long motor cables.
Recommended actions
1) If possible, rewrite the user program to reduce the amount of hard
acceleration and hard deceleration.
2) Reduce the static torque due to gravity or external forces.
3) Check for short circuit in the motor cable or in the motor.
4) Check for other hardware eventlogs.
50418, Drive unit overload warning
Description
The drive unit for joint arg , connected to drive module arg with the
drive unit at unit position arg and node arg is approaching a too high
temperature level.
Consequences
It is possible to continue but margin to max temperature is too low for
long term operation.
Probable causes
1) The joint may be running with a too high torque for extended
periods of time.
2) Short circuit in the manipulator using long motor cables.
Recommended actions
1) If possible, rewrite the user program to reduce the amount of hard
acceleration and hard deceleration.
2) Reduce the static torque due to gravity or external forces.
3) Check for short circuit in the motor cable or in the motor.
4) Check for other hardware eventlogs.
50419, Common base_frame error
Description
Task: arg
The base_frame is moved by another task than the robot and could not
be solved, reason arg :
1 SingArea\Wrist not supported with MoveC.
2 The base_frame must be moved by first synchronized motion_group.
3 Only one common base_frame can be handled.
4 Absacc not supported with MoveC.
5 The common base_frame can only be solved in synchronized move.
Program Ref. arg
Recommended actions
1 Use SingArea\Off. The CirPathMode can also be used.
2,3 Check SYS.cfg and MOC.cfg.
4 Use MoveL or remove absacc.
5 Use MoveAbsJ.
50420, IndCnv Mechanical Unit Error
Description
The mechanical unit arg is not correctly configured for IndCnv
functionality.
Consequences
Program execution is stopped.
Probable causes
The mechanical unit arg consists of more than one single.
The single connected to arg is not of type FREE_ROT.
The single connected to arg is not defined as an Indexing Move single.
6 Trouble shooting by Event log
312
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Make sure mechanical unit arg consists of only one single.
Make sure configuration parameter Motion/Single Type/Mechanics is
of type FREE_ROT.
Make sure configuration parameter Motion/Single Type/Indexing
Move is TRUE.
50421, IndCnv Tracking Single Error
Description
The single arg is not configured as an Indexing Move single
Consequences
Program execution is stopped.
Recommended actions
Make sure configuration parameter Process/Can Interface/Single To
Track refers to a single with Motion/Single Type/Indexing Move set to
TRUE.
50422, IndCnv and Independent joint error
Description
Independent joint instructions are not allowed when single arg is in
indexing mode.
Consequences
Program execution is stopped.
Recommended actions
Execute the RAPID instruction IndCnvReset before using the axis as
an independent joint.
50423, IndCnv Time before indexing move too
low
Description
The time between trig signal and start of indexing movement is
configured too low.
Consequences
The program execution is stopped.
Recommended actions
Increase system parameter "Motion/Single Type/Time before indexing
move" to at least arg (ms).
Remove or decrease robot acceleration limitations if possible.
Please consult the Conveyor Tracking application manual for further
actions.
50424, IndCnv Robot type not supported
Description
The IndCnv functionality does not support the installed robot type.
Consequences
The program execution is stopped.
50425, Friction FFW parameter is not On
Description
Tuning friction parameters requires Friction FFW On to be set to True.
Consequences
Friction tuning for joint arg will have no effect.
Recommended actions
Set parameter Friction FFW On to True for joint arg in the type arg that
belongs to the topic Motion.
50426, Out of interpolation objects
Description
The maximum number of available interpolation objects has been
reached. This can occur if the dynamic performance is set to a very low
value e.g. by use of the AccSet command.
Consequences
The program execution is stopped and the system goes to motors off.
Recommended actions
Increase the number of objects by adding 'extended_dec_dist 1' in cfg
instance MOTION_PLANNER.
6,
Description
71001, Duplicated address
Description
The I/O configuration is invalid.
The same addresses have been given for I/O unit < arg > and I/O unit
< arg >.
I/O units connected to the same I/O bus must have unique addresses.
This I/O unit has been rejected.
Recommended actions
1. Check that addresses are correct.
2. Check that the I/O units are connected to the correct I/O bus.
71002, Unit type undefined
Description
The I/O configuration for I/O unit < arg > is invalid.
Consequences
This unit type has been rejected, and no functions depending on this
unit type will work.
Probable causes
The unit type < arg > is unknown. All I/O units must refer to an existing,
defined unit type.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 314
|
6 Trouble shooting by Event log
311
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
50415, Motor temperature error
Description
Motor temperature for joint arg is too high.
Consequences
It is not possible to continue until the motor has cooled down. The
system goes to Motors Off state.
Probable causes
The user program may contain too much hard acceleration and
deceleration of the joint. Gravity torque or external forces for the joint
can also be too high.
Recommended actions
Rewrite the user program to reduce the motor utilization.
50416, Motor temperature warning
Description
The motor temperature for joint arg is close to maximum value.
Consequences
It is possible to continue but the margin to maximum allowed
temperature is too low to sustain long term operation.
Probable causes
The user program may contain too much hard acceleration and hard
deceleration of the joint. The gravity torque or external forces for the
joint can also be too high.
Recommended actions
Rewrite the user program to reduce the motor utilization.
50417, Drive unit overload error
Description
The drive unit for joint arg has reached a too high temperature level.
The joint is connected to drive module arg with the drive unit at unit
position arg and node arg .
Consequences
No operation will be possible until the drive has cooled down. The
system goes to Motors Off state.
Probable causes
1) The joint may be running with a too high torque for extended
periods of time.
2) Short circuit in the manipulator using long motor cables.
Recommended actions
1) If possible, rewrite the user program to reduce the amount of hard
acceleration and hard deceleration.
2) Reduce the static torque due to gravity or external forces.
3) Check for short circuit in the motor cable or in the motor.
4) Check for other hardware eventlogs.
50418, Drive unit overload warning
Description
The drive unit for joint arg , connected to drive module arg with the
drive unit at unit position arg and node arg is approaching a too high
temperature level.
Consequences
It is possible to continue but margin to max temperature is too low for
long term operation.
Probable causes
1) The joint may be running with a too high torque for extended
periods of time.
2) Short circuit in the manipulator using long motor cables.
Recommended actions
1) If possible, rewrite the user program to reduce the amount of hard
acceleration and hard deceleration.
2) Reduce the static torque due to gravity or external forces.
3) Check for short circuit in the motor cable or in the motor.
4) Check for other hardware eventlogs.
50419, Common base_frame error
Description
Task: arg
The base_frame is moved by another task than the robot and could not
be solved, reason arg :
1 SingArea\Wrist not supported with MoveC.
2 The base_frame must be moved by first synchronized motion_group.
3 Only one common base_frame can be handled.
4 Absacc not supported with MoveC.
5 The common base_frame can only be solved in synchronized move.
Program Ref. arg
Recommended actions
1 Use SingArea\Off. The CirPathMode can also be used.
2,3 Check SYS.cfg and MOC.cfg.
4 Use MoveL or remove absacc.
5 Use MoveAbsJ.
50420, IndCnv Mechanical Unit Error
Description
The mechanical unit arg is not correctly configured for IndCnv
functionality.
Consequences
Program execution is stopped.
Probable causes
The mechanical unit arg consists of more than one single.
The single connected to arg is not of type FREE_ROT.
The single connected to arg is not defined as an Indexing Move single.
6 Trouble shooting by Event log
312
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Make sure mechanical unit arg consists of only one single.
Make sure configuration parameter Motion/Single Type/Mechanics is
of type FREE_ROT.
Make sure configuration parameter Motion/Single Type/Indexing
Move is TRUE.
50421, IndCnv Tracking Single Error
Description
The single arg is not configured as an Indexing Move single
Consequences
Program execution is stopped.
Recommended actions
Make sure configuration parameter Process/Can Interface/Single To
Track refers to a single with Motion/Single Type/Indexing Move set to
TRUE.
50422, IndCnv and Independent joint error
Description
Independent joint instructions are not allowed when single arg is in
indexing mode.
Consequences
Program execution is stopped.
Recommended actions
Execute the RAPID instruction IndCnvReset before using the axis as
an independent joint.
50423, IndCnv Time before indexing move too
low
Description
The time between trig signal and start of indexing movement is
configured too low.
Consequences
The program execution is stopped.
Recommended actions
Increase system parameter "Motion/Single Type/Time before indexing
move" to at least arg (ms).
Remove or decrease robot acceleration limitations if possible.
Please consult the Conveyor Tracking application manual for further
actions.
50424, IndCnv Robot type not supported
Description
The IndCnv functionality does not support the installed robot type.
Consequences
The program execution is stopped.
50425, Friction FFW parameter is not On
Description
Tuning friction parameters requires Friction FFW On to be set to True.
Consequences
Friction tuning for joint arg will have no effect.
Recommended actions
Set parameter Friction FFW On to True for joint arg in the type arg that
belongs to the topic Motion.
50426, Out of interpolation objects
Description
The maximum number of available interpolation objects has been
reached. This can occur if the dynamic performance is set to a very low
value e.g. by use of the AccSet command.
Consequences
The program execution is stopped and the system goes to motors off.
Recommended actions
Increase the number of objects by adding 'extended_dec_dist 1' in cfg
instance MOTION_PLANNER.
6,
Description
71001, Duplicated address
Description
The I/O configuration is invalid.
The same addresses have been given for I/O unit < arg > and I/O unit
< arg >.
I/O units connected to the same I/O bus must have unique addresses.
This I/O unit has been rejected.
Recommended actions
1. Check that addresses are correct.
2. Check that the I/O units are connected to the correct I/O bus.
71002, Unit type undefined
Description
The I/O configuration for I/O unit < arg > is invalid.
Consequences
This unit type has been rejected, and no functions depending on this
unit type will work.
Probable causes
The unit type < arg > is unknown. All I/O units must refer to an existing,
defined unit type.
6 Trouble shooting by Event log
313
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Make sure the unit type is defined.
2. Make sure the unit type is correctly spelt.
71003, I/O unit undefined
Description
The I/O configuration for I/O signal < arg > is invalid.
Consequences
This I/O signal has been rejected, and no functions depending on it will
work.
Probable causes
The I/O unit < arg > is unknown. All I/O signals must refer to an
existing/defined I/O unit.
Recommended actions
1. Make sure the I/O unit is defined.
2. Make sure the I/O unit name is correctly spelt.
71005, Invalid filter time
Description
The I/O configuration for I/O signal < arg > is invalid.
The passive filter time should either be 0 ms or in the range [ arg , arg ]
ms.
This I/O signal has been rejected.
Recommended actions
Correct the passive filter time for the I/O signal.
71006, Invalid filter time
Description
The I/O configuration for I/O signal < arg > is invalid.
The active filter time should either be 0 ms or in the range [ arg , arg ]
ms.
This I/O signal has been rejected.
Recommended actions
Correct the active filter time for the I/O signal.
71007, Logical values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The logical minimum value must be less than the logical maximum
value.
This I/O signal has been rejected.
Recommended actions
Correct the logical values for the I/O signal so that the minimum value
becomes less than the maximum value.
71008, Physical values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The physical minimum value must be less than the physical maximum
value.
This I/O signal has been rejected.
Recommended actions
Correct the physical values for the I/O signal so that the minimum
value becomes less than the maximum value.
71017, Cross connection without actor I/O
signal
Description
The I/O configuration is invalid.
The parameter <Actor arg > of one of the cross connections have been
omitted.
Rules:
1. All cross connections must specify at least one actor signal, i.e.
parameter <Actor I/O signal 1> must always be specified.
2. For each operator specified an actor I/O signal must follow, e.g. if
parameter <Operator 2> is specified then parameter <Actor 3> must
also be specified.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so the required actor I/O signals are
specified.
71019, I/O signal undefined
Description
The I/O configuration of a cross connection is invalid.
Consequences
The cross connection has been rejected, and no functions depending on
it will work.
Probable causes
The parameter <Actor arg > of one of the cross connections contains a
reference to an undefined I/O signal < arg >.
Recommended actions
1. Make sure the I/O signal is defined.
2. Make sure the I/O signal name is correctly spelt.
71020, Cross connection without resultant I/O
signal
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
have been omitted.
All cross connections must specify a resultant I/O signal.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 315
|
6 Trouble shooting by Event log
312
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Make sure mechanical unit arg consists of only one single.
Make sure configuration parameter Motion/Single Type/Mechanics is
of type FREE_ROT.
Make sure configuration parameter Motion/Single Type/Indexing
Move is TRUE.
50421, IndCnv Tracking Single Error
Description
The single arg is not configured as an Indexing Move single
Consequences
Program execution is stopped.
Recommended actions
Make sure configuration parameter Process/Can Interface/Single To
Track refers to a single with Motion/Single Type/Indexing Move set to
TRUE.
50422, IndCnv and Independent joint error
Description
Independent joint instructions are not allowed when single arg is in
indexing mode.
Consequences
Program execution is stopped.
Recommended actions
Execute the RAPID instruction IndCnvReset before using the axis as
an independent joint.
50423, IndCnv Time before indexing move too
low
Description
The time between trig signal and start of indexing movement is
configured too low.
Consequences
The program execution is stopped.
Recommended actions
Increase system parameter "Motion/Single Type/Time before indexing
move" to at least arg (ms).
Remove or decrease robot acceleration limitations if possible.
Please consult the Conveyor Tracking application manual for further
actions.
50424, IndCnv Robot type not supported
Description
The IndCnv functionality does not support the installed robot type.
Consequences
The program execution is stopped.
50425, Friction FFW parameter is not On
Description
Tuning friction parameters requires Friction FFW On to be set to True.
Consequences
Friction tuning for joint arg will have no effect.
Recommended actions
Set parameter Friction FFW On to True for joint arg in the type arg that
belongs to the topic Motion.
50426, Out of interpolation objects
Description
The maximum number of available interpolation objects has been
reached. This can occur if the dynamic performance is set to a very low
value e.g. by use of the AccSet command.
Consequences
The program execution is stopped and the system goes to motors off.
Recommended actions
Increase the number of objects by adding 'extended_dec_dist 1' in cfg
instance MOTION_PLANNER.
6,
Description
71001, Duplicated address
Description
The I/O configuration is invalid.
The same addresses have been given for I/O unit < arg > and I/O unit
< arg >.
I/O units connected to the same I/O bus must have unique addresses.
This I/O unit has been rejected.
Recommended actions
1. Check that addresses are correct.
2. Check that the I/O units are connected to the correct I/O bus.
71002, Unit type undefined
Description
The I/O configuration for I/O unit < arg > is invalid.
Consequences
This unit type has been rejected, and no functions depending on this
unit type will work.
Probable causes
The unit type < arg > is unknown. All I/O units must refer to an existing,
defined unit type.
6 Trouble shooting by Event log
313
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Make sure the unit type is defined.
2. Make sure the unit type is correctly spelt.
71003, I/O unit undefined
Description
The I/O configuration for I/O signal < arg > is invalid.
Consequences
This I/O signal has been rejected, and no functions depending on it will
work.
Probable causes
The I/O unit < arg > is unknown. All I/O signals must refer to an
existing/defined I/O unit.
Recommended actions
1. Make sure the I/O unit is defined.
2. Make sure the I/O unit name is correctly spelt.
71005, Invalid filter time
Description
The I/O configuration for I/O signal < arg > is invalid.
The passive filter time should either be 0 ms or in the range [ arg , arg ]
ms.
This I/O signal has been rejected.
Recommended actions
Correct the passive filter time for the I/O signal.
71006, Invalid filter time
Description
The I/O configuration for I/O signal < arg > is invalid.
The active filter time should either be 0 ms or in the range [ arg , arg ]
ms.
This I/O signal has been rejected.
Recommended actions
Correct the active filter time for the I/O signal.
71007, Logical values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The logical minimum value must be less than the logical maximum
value.
This I/O signal has been rejected.
Recommended actions
Correct the logical values for the I/O signal so that the minimum value
becomes less than the maximum value.
71008, Physical values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The physical minimum value must be less than the physical maximum
value.
This I/O signal has been rejected.
Recommended actions
Correct the physical values for the I/O signal so that the minimum
value becomes less than the maximum value.
71017, Cross connection without actor I/O
signal
Description
The I/O configuration is invalid.
The parameter <Actor arg > of one of the cross connections have been
omitted.
Rules:
1. All cross connections must specify at least one actor signal, i.e.
parameter <Actor I/O signal 1> must always be specified.
2. For each operator specified an actor I/O signal must follow, e.g. if
parameter <Operator 2> is specified then parameter <Actor 3> must
also be specified.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so the required actor I/O signals are
specified.
71019, I/O signal undefined
Description
The I/O configuration of a cross connection is invalid.
Consequences
The cross connection has been rejected, and no functions depending on
it will work.
Probable causes
The parameter <Actor arg > of one of the cross connections contains a
reference to an undefined I/O signal < arg >.
Recommended actions
1. Make sure the I/O signal is defined.
2. Make sure the I/O signal name is correctly spelt.
71020, Cross connection without resultant I/O
signal
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
have been omitted.
All cross connections must specify a resultant I/O signal.
6 Trouble shooting by Event log
314
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so that there are one resultant I/O signal
per cross connection.
71021, Duplicated cross connection resultants
Description
The I/O configuration is invalid.
Multiple cross connections have the same resultant I/O signal < arg >.
Having more than one cross connection that result in the setting of the
same signal may cause unpredictable behaviours, as you cannot
control their order of evaluation.
The complete cross connection configuration has been rejected.
Recommended actions
Make sure that the I/O signal is not specified as the resultant of several
cross connections.
71037, Closed chain in cross connection
Description
The I/O configuration is invalid.
The I/O signal < arg > is part of a cross connection chain that is closed
(i.e. forms a circular dependence that cannot be evaluated).
The complete cross connection configuration has been rejected.
Recommended actions
Correct the configuration for the cross connections where the I/O
signal above is part.
71038, Cross connection max depth exceeded
Description
The I/O configuration is invalid.
The I/O signal < arg > is part of a cross connection chain that is too
deep.
The maximum depth of a cross connection chain is < arg >.
The complete cross connection configuration has been rejected.
Recommended actions
Make the cross connection less deep.
71045, Invalid filter specification
Description
The I/O configuration for I/O signal < arg > is invalid.
No filter times can be specified for this type of I/O signal.
This I/O signal has been rejected.
Recommended actions
Set filter time to 0 or remove the statement.
71049, Analog I/O signal inverted
Description
The I/O configuration for I/O signal < arg > is invalid.
Analog I/O signals must not be inverted.
Only digital and group I/O signals can be inverted.
This I/O signal has been rejected.
Recommended actions
Remove the invert for the I/O signal (or change the signal type).
71050, Cross connection with non-digital actor
I/O signal
Description
The I/O configuration is invalid.
The parameter <Actor arg > of one of the cross connections refer to a
I/O signal < arg >, that is not digital.
Only digital I/O signals can be cross connected.
This cross connection has been rejected.
Recommended actions
Remove the non-digital I/O signal from the cross connection.
71052, Max number of cross connections
exceeded
Description
The I/O configuration is invalid.
The maximum number of cross connections, arg ,in the I/O system has
been exceeded.
Not all the cross connections have been accepted.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
cross connections) so that the maximum limit is not exceeded.
71054, Invalid signal type
Description
The I/O configuration for I/O signal < arg > is invalid.
The specified signal type < arg > is invalid/unknown.
Valid signal types are:
- DI (Digital input)
- DO (Digital output)
- AI (Analog input)
- AO (Analog output)
- GI (Group input)
- GO (Group output)
This I/O signal has been rejected.
Recommended actions
Correct the signal type of the I/O signal.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 316
|
6 Trouble shooting by Event log
313
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Make sure the unit type is defined.
2. Make sure the unit type is correctly spelt.
71003, I/O unit undefined
Description
The I/O configuration for I/O signal < arg > is invalid.
Consequences
This I/O signal has been rejected, and no functions depending on it will
work.
Probable causes
The I/O unit < arg > is unknown. All I/O signals must refer to an
existing/defined I/O unit.
Recommended actions
1. Make sure the I/O unit is defined.
2. Make sure the I/O unit name is correctly spelt.
71005, Invalid filter time
Description
The I/O configuration for I/O signal < arg > is invalid.
The passive filter time should either be 0 ms or in the range [ arg , arg ]
ms.
This I/O signal has been rejected.
Recommended actions
Correct the passive filter time for the I/O signal.
71006, Invalid filter time
Description
The I/O configuration for I/O signal < arg > is invalid.
The active filter time should either be 0 ms or in the range [ arg , arg ]
ms.
This I/O signal has been rejected.
Recommended actions
Correct the active filter time for the I/O signal.
71007, Logical values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The logical minimum value must be less than the logical maximum
value.
This I/O signal has been rejected.
Recommended actions
Correct the logical values for the I/O signal so that the minimum value
becomes less than the maximum value.
71008, Physical values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The physical minimum value must be less than the physical maximum
value.
This I/O signal has been rejected.
Recommended actions
Correct the physical values for the I/O signal so that the minimum
value becomes less than the maximum value.
71017, Cross connection without actor I/O
signal
Description
The I/O configuration is invalid.
The parameter <Actor arg > of one of the cross connections have been
omitted.
Rules:
1. All cross connections must specify at least one actor signal, i.e.
parameter <Actor I/O signal 1> must always be specified.
2. For each operator specified an actor I/O signal must follow, e.g. if
parameter <Operator 2> is specified then parameter <Actor 3> must
also be specified.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so the required actor I/O signals are
specified.
71019, I/O signal undefined
Description
The I/O configuration of a cross connection is invalid.
Consequences
The cross connection has been rejected, and no functions depending on
it will work.
Probable causes
The parameter <Actor arg > of one of the cross connections contains a
reference to an undefined I/O signal < arg >.
Recommended actions
1. Make sure the I/O signal is defined.
2. Make sure the I/O signal name is correctly spelt.
71020, Cross connection without resultant I/O
signal
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
have been omitted.
All cross connections must specify a resultant I/O signal.
6 Trouble shooting by Event log
314
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so that there are one resultant I/O signal
per cross connection.
71021, Duplicated cross connection resultants
Description
The I/O configuration is invalid.
Multiple cross connections have the same resultant I/O signal < arg >.
Having more than one cross connection that result in the setting of the
same signal may cause unpredictable behaviours, as you cannot
control their order of evaluation.
The complete cross connection configuration has been rejected.
Recommended actions
Make sure that the I/O signal is not specified as the resultant of several
cross connections.
71037, Closed chain in cross connection
Description
The I/O configuration is invalid.
The I/O signal < arg > is part of a cross connection chain that is closed
(i.e. forms a circular dependence that cannot be evaluated).
The complete cross connection configuration has been rejected.
Recommended actions
Correct the configuration for the cross connections where the I/O
signal above is part.
71038, Cross connection max depth exceeded
Description
The I/O configuration is invalid.
The I/O signal < arg > is part of a cross connection chain that is too
deep.
The maximum depth of a cross connection chain is < arg >.
The complete cross connection configuration has been rejected.
Recommended actions
Make the cross connection less deep.
71045, Invalid filter specification
Description
The I/O configuration for I/O signal < arg > is invalid.
No filter times can be specified for this type of I/O signal.
This I/O signal has been rejected.
Recommended actions
Set filter time to 0 or remove the statement.
71049, Analog I/O signal inverted
Description
The I/O configuration for I/O signal < arg > is invalid.
Analog I/O signals must not be inverted.
Only digital and group I/O signals can be inverted.
This I/O signal has been rejected.
Recommended actions
Remove the invert for the I/O signal (or change the signal type).
71050, Cross connection with non-digital actor
I/O signal
Description
The I/O configuration is invalid.
The parameter <Actor arg > of one of the cross connections refer to a
I/O signal < arg >, that is not digital.
Only digital I/O signals can be cross connected.
This cross connection has been rejected.
Recommended actions
Remove the non-digital I/O signal from the cross connection.
71052, Max number of cross connections
exceeded
Description
The I/O configuration is invalid.
The maximum number of cross connections, arg ,in the I/O system has
been exceeded.
Not all the cross connections have been accepted.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
cross connections) so that the maximum limit is not exceeded.
71054, Invalid signal type
Description
The I/O configuration for I/O signal < arg > is invalid.
The specified signal type < arg > is invalid/unknown.
Valid signal types are:
- DI (Digital input)
- DO (Digital output)
- AI (Analog input)
- AO (Analog output)
- GI (Group input)
- GO (Group output)
This I/O signal has been rejected.
Recommended actions
Correct the signal type of the I/O signal.
6 Trouble shooting by Event log
315
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71058, Lost communication with I/O unit
Description
The previously working communication with I/O unit < arg > on I/O
bus < arg > has been lost.
Consequences
It is not possible to access the I/O unit itself or I/O signals on the I/O
unit since it is currently not communicating with the controller. The
system will go to state SYS FAIL, if the I/O unit has been assigned
Unit Trustlevel Required (0) in the configuration.
Probable causes
The I/O unit may have been disconnected from the system.
Recommended actions
1. Make sure the I/O unit has been correctly installed.
2. Make sure the cabling to the I/O unit is correctly connected.
71061, Communication failure on I/O bus
Description
A communication failure on I/O bus < arg > has been detected.
Recommended actions
1. Check other messages for fieldbus specific error.
2. If no I/O units are configured to I/O bus, configure I/O units or
remove bus configuration.
71072, Cannot read stored signal value
Description
Cannot read the stored signal value for I/O signal < arg > as it is not
stored.
Recommended actions
Change the configuration of the I/O signal by setting the store attribute.
71076, Communication error from rtp1
Description
No response from the serial line.
Recommended actions
Check the device or connection.
71077, Communication error from rtp1
Description
Not possible to deliver the received message.
Recommended actions
Check the communication flow.
71078, Communication error from rtp1
Description
The response from the device has an invalid frame sequence.
Recommended actions
Check for noise on the serial line.
71080, Max number of unit types exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of unit types in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
unit types) so that the maximum limit is not exceeded.
71081, Max number of physical I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of physical I/O signals (bit-mappings) in
the I/O system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
physical I/O signals) so that the maximum limit is not exceeded.
71082, Max number of user I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of user I/O signals in the I/O system has
been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O signals) so that the maximum limit is not exceeded.
71083, Max number of symbols exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of symbols in the I/O system has been
exceeded.
The number of symbols is the sum of all namned configuration
instances:
- I/O Buses
- Unit types
- I/O Units
- I/O Signals
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 317
|
6 Trouble shooting by Event log
314
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so that there are one resultant I/O signal
per cross connection.
71021, Duplicated cross connection resultants
Description
The I/O configuration is invalid.
Multiple cross connections have the same resultant I/O signal < arg >.
Having more than one cross connection that result in the setting of the
same signal may cause unpredictable behaviours, as you cannot
control their order of evaluation.
The complete cross connection configuration has been rejected.
Recommended actions
Make sure that the I/O signal is not specified as the resultant of several
cross connections.
71037, Closed chain in cross connection
Description
The I/O configuration is invalid.
The I/O signal < arg > is part of a cross connection chain that is closed
(i.e. forms a circular dependence that cannot be evaluated).
The complete cross connection configuration has been rejected.
Recommended actions
Correct the configuration for the cross connections where the I/O
signal above is part.
71038, Cross connection max depth exceeded
Description
The I/O configuration is invalid.
The I/O signal < arg > is part of a cross connection chain that is too
deep.
The maximum depth of a cross connection chain is < arg >.
The complete cross connection configuration has been rejected.
Recommended actions
Make the cross connection less deep.
71045, Invalid filter specification
Description
The I/O configuration for I/O signal < arg > is invalid.
No filter times can be specified for this type of I/O signal.
This I/O signal has been rejected.
Recommended actions
Set filter time to 0 or remove the statement.
71049, Analog I/O signal inverted
Description
The I/O configuration for I/O signal < arg > is invalid.
Analog I/O signals must not be inverted.
Only digital and group I/O signals can be inverted.
This I/O signal has been rejected.
Recommended actions
Remove the invert for the I/O signal (or change the signal type).
71050, Cross connection with non-digital actor
I/O signal
Description
The I/O configuration is invalid.
The parameter <Actor arg > of one of the cross connections refer to a
I/O signal < arg >, that is not digital.
Only digital I/O signals can be cross connected.
This cross connection has been rejected.
Recommended actions
Remove the non-digital I/O signal from the cross connection.
71052, Max number of cross connections
exceeded
Description
The I/O configuration is invalid.
The maximum number of cross connections, arg ,in the I/O system has
been exceeded.
Not all the cross connections have been accepted.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
cross connections) so that the maximum limit is not exceeded.
71054, Invalid signal type
Description
The I/O configuration for I/O signal < arg > is invalid.
The specified signal type < arg > is invalid/unknown.
Valid signal types are:
- DI (Digital input)
- DO (Digital output)
- AI (Analog input)
- AO (Analog output)
- GI (Group input)
- GO (Group output)
This I/O signal has been rejected.
Recommended actions
Correct the signal type of the I/O signal.
6 Trouble shooting by Event log
315
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71058, Lost communication with I/O unit
Description
The previously working communication with I/O unit < arg > on I/O
bus < arg > has been lost.
Consequences
It is not possible to access the I/O unit itself or I/O signals on the I/O
unit since it is currently not communicating with the controller. The
system will go to state SYS FAIL, if the I/O unit has been assigned
Unit Trustlevel Required (0) in the configuration.
Probable causes
The I/O unit may have been disconnected from the system.
Recommended actions
1. Make sure the I/O unit has been correctly installed.
2. Make sure the cabling to the I/O unit is correctly connected.
71061, Communication failure on I/O bus
Description
A communication failure on I/O bus < arg > has been detected.
Recommended actions
1. Check other messages for fieldbus specific error.
2. If no I/O units are configured to I/O bus, configure I/O units or
remove bus configuration.
71072, Cannot read stored signal value
Description
Cannot read the stored signal value for I/O signal < arg > as it is not
stored.
Recommended actions
Change the configuration of the I/O signal by setting the store attribute.
71076, Communication error from rtp1
Description
No response from the serial line.
Recommended actions
Check the device or connection.
71077, Communication error from rtp1
Description
Not possible to deliver the received message.
Recommended actions
Check the communication flow.
71078, Communication error from rtp1
Description
The response from the device has an invalid frame sequence.
Recommended actions
Check for noise on the serial line.
71080, Max number of unit types exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of unit types in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
unit types) so that the maximum limit is not exceeded.
71081, Max number of physical I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of physical I/O signals (bit-mappings) in
the I/O system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
physical I/O signals) so that the maximum limit is not exceeded.
71082, Max number of user I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of user I/O signals in the I/O system has
been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O signals) so that the maximum limit is not exceeded.
71083, Max number of symbols exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of symbols in the I/O system has been
exceeded.
The number of symbols is the sum of all namned configuration
instances:
- I/O Buses
- Unit types
- I/O Units
- I/O Signals
6 Trouble shooting by Event log
316
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- Command types
- Commands
- I/O Access levels
- CIP Routes
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
symbols) so that the maximum limit is not exceeded.
71084, Max number of subscribed I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of subscribed I/O signals in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
subscriptions) so that the maximum limit is not exceeded.
71085, Max number of I/O units exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O units in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O units) so that the maximum limit is not exceeded.
71097, Input I/O signal stored
Description
The I/O configuration for I/O signal < arg > is invalid.
Input I/O signals must not be stored.
Only output I/O signals can be stored.
This I/O signal has been rejected.
Recommended actions
Remove the store for the I/O signal (or change the signal type).
71098, NFS server lost
Description
The contact with the NFS server < arg > is lost.
Recommended actions
1. The NFS server.
2. The network connection.
3. The controller configuration.
71099, Trusted NFS server lost
Description
The contact with the trusted NFS server < arg > is lost.
Recommended actions
1. The NFS server.
2. The network connection.
3. The controller configuration.
71100, Max number of I/O buses exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O buses in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O buses) so that the maximum limit is not exceeded.
71101, I/O bus undefined
Description
The I/O configuration for I/O unit < arg > is invalid.
The I/O bus < arg > cannot be found in the system. An I/O unit must
refer to a defined I/O bus.
Installed I/O buses are: argargarg
Consequences
This I/O unit has been rejected, and no functions depending on it will
work.
Recommended actions
1. Make sure the I/O bus is defined.
2. Make sure the I/O bus name is correctly spelt.
71108, Interbus I/O unit failure
Description
I/O unit < arg > at address < arg > reported peripheral fault. Interbus
specific error code: arg .
Consequences
The I/O unit cannot be contacted by the control system. Parts of the
Interbus network will not be accessible, depending on the network
topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the I/O unit at the above address is functioning correctly.
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 318
|
6 Trouble shooting by Event log
315
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71058, Lost communication with I/O unit
Description
The previously working communication with I/O unit < arg > on I/O
bus < arg > has been lost.
Consequences
It is not possible to access the I/O unit itself or I/O signals on the I/O
unit since it is currently not communicating with the controller. The
system will go to state SYS FAIL, if the I/O unit has been assigned
Unit Trustlevel Required (0) in the configuration.
Probable causes
The I/O unit may have been disconnected from the system.
Recommended actions
1. Make sure the I/O unit has been correctly installed.
2. Make sure the cabling to the I/O unit is correctly connected.
71061, Communication failure on I/O bus
Description
A communication failure on I/O bus < arg > has been detected.
Recommended actions
1. Check other messages for fieldbus specific error.
2. If no I/O units are configured to I/O bus, configure I/O units or
remove bus configuration.
71072, Cannot read stored signal value
Description
Cannot read the stored signal value for I/O signal < arg > as it is not
stored.
Recommended actions
Change the configuration of the I/O signal by setting the store attribute.
71076, Communication error from rtp1
Description
No response from the serial line.
Recommended actions
Check the device or connection.
71077, Communication error from rtp1
Description
Not possible to deliver the received message.
Recommended actions
Check the communication flow.
71078, Communication error from rtp1
Description
The response from the device has an invalid frame sequence.
Recommended actions
Check for noise on the serial line.
71080, Max number of unit types exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of unit types in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
unit types) so that the maximum limit is not exceeded.
71081, Max number of physical I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of physical I/O signals (bit-mappings) in
the I/O system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
physical I/O signals) so that the maximum limit is not exceeded.
71082, Max number of user I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of user I/O signals in the I/O system has
been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O signals) so that the maximum limit is not exceeded.
71083, Max number of symbols exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of symbols in the I/O system has been
exceeded.
The number of symbols is the sum of all namned configuration
instances:
- I/O Buses
- Unit types
- I/O Units
- I/O Signals
6 Trouble shooting by Event log
316
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- Command types
- Commands
- I/O Access levels
- CIP Routes
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
symbols) so that the maximum limit is not exceeded.
71084, Max number of subscribed I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of subscribed I/O signals in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
subscriptions) so that the maximum limit is not exceeded.
71085, Max number of I/O units exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O units in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O units) so that the maximum limit is not exceeded.
71097, Input I/O signal stored
Description
The I/O configuration for I/O signal < arg > is invalid.
Input I/O signals must not be stored.
Only output I/O signals can be stored.
This I/O signal has been rejected.
Recommended actions
Remove the store for the I/O signal (or change the signal type).
71098, NFS server lost
Description
The contact with the NFS server < arg > is lost.
Recommended actions
1. The NFS server.
2. The network connection.
3. The controller configuration.
71099, Trusted NFS server lost
Description
The contact with the trusted NFS server < arg > is lost.
Recommended actions
1. The NFS server.
2. The network connection.
3. The controller configuration.
71100, Max number of I/O buses exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O buses in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O buses) so that the maximum limit is not exceeded.
71101, I/O bus undefined
Description
The I/O configuration for I/O unit < arg > is invalid.
The I/O bus < arg > cannot be found in the system. An I/O unit must
refer to a defined I/O bus.
Installed I/O buses are: argargarg
Consequences
This I/O unit has been rejected, and no functions depending on it will
work.
Recommended actions
1. Make sure the I/O bus is defined.
2. Make sure the I/O bus name is correctly spelt.
71108, Interbus I/O unit failure
Description
I/O unit < arg > at address < arg > reported peripheral fault. Interbus
specific error code: arg .
Consequences
The I/O unit cannot be contacted by the control system. Parts of the
Interbus network will not be accessible, depending on the network
topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the I/O unit at the above address is functioning correctly.
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
6 Trouble shooting by Event log
317
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71109, Interbus bus failure
Description
The control system has lost communication with the Interbus network.
There is no error message from any Interbus board.
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the Customer Power Supply unit, supplying the
Interbus network with power, is working correctly. Replace any faulty
I/O unit.
2. Make sure any fuses are correctly connected.
3. Make sure all communication cables and connectors are working
correctly and of the recommended type.
4. Check network topology and cable length.
5. Restart the system.
71110, Interbus bus failure
Description
The control system has lost communication with the I/O unit at address
< arg . arg >. Interbus specific error code: arg .
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the I/O unit at the above address is functioning correctly.
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71111, ID code mismatch
Description
The ID code < arg > read from Interbus I/O unit < arg > doesn't match
the expected value arg from the unit type configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
Wrong ID code value may have been introduced to the system
parameters. The Interbus network may have been configured with a I/
O unit with the wrong ID code.
Recommended actions
Check the ID code of the I/O unit's unit type in the system parameters.
How to check the configuration file is detailed in the Trouble Shooting
Manual.
2. Replace the I/O unit with another using the correct ID code in the
Interbus configuration as specified in the supplier's documentation.
3. Specify a generic unit type in the system parameters: ibsGeneric and
ibsSlave.
71114, Invalid IP address
Description
The IP address < arg > is not valid.
Recommended actions
Check the communication configuration.
71115, Invalid subnet mask
Description
The subnet mask < arg > is not valid.
Recommended actions
Check the communication configuration.
71116, Deactivated I/O unit with Unit Trustlevel
<Required (0)>
Description
The I/O configuration of I/O unit < arg > is invalid.
I/O units with Unit Trustlevel Required (0) are not allowed to be
Deactivated.
Consequences
This I/O unit has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the configuration of the I/O unit by either Activating it or
changing the Unit Trustlevel.
71122, Incorrect IP address
Description
The address < arg > in protocol < arg > is not a correct IP address.
Recommended actions
Correct the address.
71123, No transmission protocol
Description
The transmission protocol < arg > given for application protocol < arg >
could not be found.
Recommended actions
Change the transmission protocol.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 319
|
6 Trouble shooting by Event log
316
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- Command types
- Commands
- I/O Access levels
- CIP Routes
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
symbols) so that the maximum limit is not exceeded.
71084, Max number of subscribed I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of subscribed I/O signals in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
subscriptions) so that the maximum limit is not exceeded.
71085, Max number of I/O units exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O units in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O units) so that the maximum limit is not exceeded.
71097, Input I/O signal stored
Description
The I/O configuration for I/O signal < arg > is invalid.
Input I/O signals must not be stored.
Only output I/O signals can be stored.
This I/O signal has been rejected.
Recommended actions
Remove the store for the I/O signal (or change the signal type).
71098, NFS server lost
Description
The contact with the NFS server < arg > is lost.
Recommended actions
1. The NFS server.
2. The network connection.
3. The controller configuration.
71099, Trusted NFS server lost
Description
The contact with the trusted NFS server < arg > is lost.
Recommended actions
1. The NFS server.
2. The network connection.
3. The controller configuration.
71100, Max number of I/O buses exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O buses in the I/O system has been
exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O buses) so that the maximum limit is not exceeded.
71101, I/O bus undefined
Description
The I/O configuration for I/O unit < arg > is invalid.
The I/O bus < arg > cannot be found in the system. An I/O unit must
refer to a defined I/O bus.
Installed I/O buses are: argargarg
Consequences
This I/O unit has been rejected, and no functions depending on it will
work.
Recommended actions
1. Make sure the I/O bus is defined.
2. Make sure the I/O bus name is correctly spelt.
71108, Interbus I/O unit failure
Description
I/O unit < arg > at address < arg > reported peripheral fault. Interbus
specific error code: arg .
Consequences
The I/O unit cannot be contacted by the control system. Parts of the
Interbus network will not be accessible, depending on the network
topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the I/O unit at the above address is functioning correctly.
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
6 Trouble shooting by Event log
317
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71109, Interbus bus failure
Description
The control system has lost communication with the Interbus network.
There is no error message from any Interbus board.
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the Customer Power Supply unit, supplying the
Interbus network with power, is working correctly. Replace any faulty
I/O unit.
2. Make sure any fuses are correctly connected.
3. Make sure all communication cables and connectors are working
correctly and of the recommended type.
4. Check network topology and cable length.
5. Restart the system.
71110, Interbus bus failure
Description
The control system has lost communication with the I/O unit at address
< arg . arg >. Interbus specific error code: arg .
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the I/O unit at the above address is functioning correctly.
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71111, ID code mismatch
Description
The ID code < arg > read from Interbus I/O unit < arg > doesn't match
the expected value arg from the unit type configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
Wrong ID code value may have been introduced to the system
parameters. The Interbus network may have been configured with a I/
O unit with the wrong ID code.
Recommended actions
Check the ID code of the I/O unit's unit type in the system parameters.
How to check the configuration file is detailed in the Trouble Shooting
Manual.
2. Replace the I/O unit with another using the correct ID code in the
Interbus configuration as specified in the supplier's documentation.
3. Specify a generic unit type in the system parameters: ibsGeneric and
ibsSlave.
71114, Invalid IP address
Description
The IP address < arg > is not valid.
Recommended actions
Check the communication configuration.
71115, Invalid subnet mask
Description
The subnet mask < arg > is not valid.
Recommended actions
Check the communication configuration.
71116, Deactivated I/O unit with Unit Trustlevel
<Required (0)>
Description
The I/O configuration of I/O unit < arg > is invalid.
I/O units with Unit Trustlevel Required (0) are not allowed to be
Deactivated.
Consequences
This I/O unit has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the configuration of the I/O unit by either Activating it or
changing the Unit Trustlevel.
71122, Incorrect IP address
Description
The address < arg > in protocol < arg > is not a correct IP address.
Recommended actions
Correct the address.
71123, No transmission protocol
Description
The transmission protocol < arg > given for application protocol < arg >
could not be found.
Recommended actions
Change the transmission protocol.
6 Trouble shooting by Event log
318
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71125, Mount Permission denied
Description
Permission was denied to mount the directory < arg > on the server
< arg >.
Recommended actions
Change the User or Group ID.
71126, Directory not exported
Description
Mounting directory < arg > as < arg > failed since it is not exported on
the server computer < arg >.
Protocol: < arg >.
Recommended actions
Export the directory on the server computer.
71128, Ethernet not installed
Description
The Ethernet Services option has to be installed when using remote
mounted disk.
Recommended actions
Reboot and install the Ethernet Services option.
71129, Too many remote disks
Description
The maximum number of remote mounted disks have been exceeded.
The maximum number is arg .
Recommended actions
Reduce the number of remote mounted disks.
71130, Too many remote servers
Description
The maximum number of servers for remote mounted disks have been
exceeded.
The maximum number is arg .
Recommended actions
1. Reduce the number of servers.
71131, Could not mount directory
Description
Mounting directory < arg > on the computer < arg > failed.
Protocol: < arg >.
Recommended actions
Check the server setup.
71139, Access error from I/O system
Description
Cannot read or write I/O signal < arg > due to communication down.
Recommended actions
Check 'No contact with I/O unit' report for more detailed information.
71141, Default value for I/O signal out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The default value is out of range.
This I/O signal has been rejected.
Recommended actions
Change the default value for the I/O signal.
71145, Interbus bus has been deactivated
Description
The Interbus bus has switched to a none running mode.
Recommended actions
Restart the system.
2. Check that correct Interbus boot project is selected.
71147, No response from the Interbus network
Description
Access to the Interbus network is denied.
Recommended actions
1. Check the Interbus board.
2. Check the internal Interbus configuration.
3. Reduce the cycle time on the slave I/O unit.
71148, No access to the Interbus network
Description
Access to the Interbus service interface is denied during arg , error code
is 0x arg .
Recommended actions
1. Check the internal Interbus configuration.
2. The Interbus may be faulty. Replace any faulty I/O unit if required.
71156, IPC queue full
Description
The interprocess communication (IPC) queue < arg > was full, when
sending to trap routine.
Recommended actions
Restart the system.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 320
|
6 Trouble shooting by Event log
317
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71109, Interbus bus failure
Description
The control system has lost communication with the Interbus network.
There is no error message from any Interbus board.
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the Customer Power Supply unit, supplying the
Interbus network with power, is working correctly. Replace any faulty
I/O unit.
2. Make sure any fuses are correctly connected.
3. Make sure all communication cables and connectors are working
correctly and of the recommended type.
4. Check network topology and cable length.
5. Restart the system.
71110, Interbus bus failure
Description
The control system has lost communication with the I/O unit at address
< arg . arg >. Interbus specific error code: arg .
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure the I/O unit at the above address is functioning correctly.
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71111, ID code mismatch
Description
The ID code < arg > read from Interbus I/O unit < arg > doesn't match
the expected value arg from the unit type configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
Wrong ID code value may have been introduced to the system
parameters. The Interbus network may have been configured with a I/
O unit with the wrong ID code.
Recommended actions
Check the ID code of the I/O unit's unit type in the system parameters.
How to check the configuration file is detailed in the Trouble Shooting
Manual.
2. Replace the I/O unit with another using the correct ID code in the
Interbus configuration as specified in the supplier's documentation.
3. Specify a generic unit type in the system parameters: ibsGeneric and
ibsSlave.
71114, Invalid IP address
Description
The IP address < arg > is not valid.
Recommended actions
Check the communication configuration.
71115, Invalid subnet mask
Description
The subnet mask < arg > is not valid.
Recommended actions
Check the communication configuration.
71116, Deactivated I/O unit with Unit Trustlevel
<Required (0)>
Description
The I/O configuration of I/O unit < arg > is invalid.
I/O units with Unit Trustlevel Required (0) are not allowed to be
Deactivated.
Consequences
This I/O unit has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the configuration of the I/O unit by either Activating it or
changing the Unit Trustlevel.
71122, Incorrect IP address
Description
The address < arg > in protocol < arg > is not a correct IP address.
Recommended actions
Correct the address.
71123, No transmission protocol
Description
The transmission protocol < arg > given for application protocol < arg >
could not be found.
Recommended actions
Change the transmission protocol.
6 Trouble shooting by Event log
318
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71125, Mount Permission denied
Description
Permission was denied to mount the directory < arg > on the server
< arg >.
Recommended actions
Change the User or Group ID.
71126, Directory not exported
Description
Mounting directory < arg > as < arg > failed since it is not exported on
the server computer < arg >.
Protocol: < arg >.
Recommended actions
Export the directory on the server computer.
71128, Ethernet not installed
Description
The Ethernet Services option has to be installed when using remote
mounted disk.
Recommended actions
Reboot and install the Ethernet Services option.
71129, Too many remote disks
Description
The maximum number of remote mounted disks have been exceeded.
The maximum number is arg .
Recommended actions
Reduce the number of remote mounted disks.
71130, Too many remote servers
Description
The maximum number of servers for remote mounted disks have been
exceeded.
The maximum number is arg .
Recommended actions
1. Reduce the number of servers.
71131, Could not mount directory
Description
Mounting directory < arg > on the computer < arg > failed.
Protocol: < arg >.
Recommended actions
Check the server setup.
71139, Access error from I/O system
Description
Cannot read or write I/O signal < arg > due to communication down.
Recommended actions
Check 'No contact with I/O unit' report for more detailed information.
71141, Default value for I/O signal out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The default value is out of range.
This I/O signal has been rejected.
Recommended actions
Change the default value for the I/O signal.
71145, Interbus bus has been deactivated
Description
The Interbus bus has switched to a none running mode.
Recommended actions
Restart the system.
2. Check that correct Interbus boot project is selected.
71147, No response from the Interbus network
Description
Access to the Interbus network is denied.
Recommended actions
1. Check the Interbus board.
2. Check the internal Interbus configuration.
3. Reduce the cycle time on the slave I/O unit.
71148, No access to the Interbus network
Description
Access to the Interbus service interface is denied during arg , error code
is 0x arg .
Recommended actions
1. Check the internal Interbus configuration.
2. The Interbus may be faulty. Replace any faulty I/O unit if required.
71156, IPC queue full
Description
The interprocess communication (IPC) queue < arg > was full, when
sending to trap routine.
Recommended actions
Restart the system.
6 Trouble shooting by Event log
319
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71158, Address out of range
Description
The I/O configuration is invalid.
The address of I/O unit < arg > is invalid (out of range).
This I/O unit has been rejected.
Recommended actions
1. Change the address.
2. Check the address syntax.
71163, I/O signal on internal I/O unit
Description
The I/O configuration is invalid.
The user-defined I/O signal < arg > must not be connected to the
internal I/O unit < arg >
User defined I/O signals are not allowed to be connected to internal I/
O units.
This I/O signal has been rejected.
Recommended actions
Connect the I/O signal to another I/O unit.
71164, Internal I/O signal in cross connection
Description
The I/O configuration contains an invalid cross connection.
The <Actor argarg > is a user-defined I/O signal whereas the resultant
I/O signal < arg > is an internal I/O signal.
It is not allowed to define cross connections where user-defined I/O
signals affect internal I/O signals.
Recommended actions
Correct the cross connection so that there are no internal I/O signals in
the resultant expression.
71165, FTP server went down
Description
The connection to a non-trusted FTP server has been lost.
IP address: < arg >.
Recommended actions
Check cable and FTP server settings.
71166, FTP server went down
Description
The connection to a trusted FTP server has been lost.
IP address: < arg >.
Recommended actions
Check cable and FTP server settings.
71167, Wrong transmission protocol
Description
No matching transmission protocol was found in the configuration.
Recommended actions
Change the transmission protocol.
71169, Ethernet not installed
Description
The option Ethernet Services with FTP is not installed on this system.
Recommended actions
Reboot and install the Ethernet Services with FTP option.
71182, I/O signal undefined
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
contains a reference to an undefined I/O signal < arg >.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so that the resultant I/O signal refers to an
existing I/O signal.
71183, Cross connection with invalid operator
Description
The I/O configuration is invalid.
The parameter <Operator arg > of one of the cross connections
contains an invalid/unknown operator < arg >.
Valid values for the logical operator are:
- AND
- OR
This cross connection has been rejected.
Recommended actions
Correct the operator.
71185, Duplicated name
Description
The I/O configuration is invalid.
The identifier < arg > has already been used as the name of another
configuration instance.
The following configuration instances must have unique names:
- I/O Buses
- Unit types
- I/O Units
- I/O Signals
- Command types
- Commands
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 321
|
6 Trouble shooting by Event log
318
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71125, Mount Permission denied
Description
Permission was denied to mount the directory < arg > on the server
< arg >.
Recommended actions
Change the User or Group ID.
71126, Directory not exported
Description
Mounting directory < arg > as < arg > failed since it is not exported on
the server computer < arg >.
Protocol: < arg >.
Recommended actions
Export the directory on the server computer.
71128, Ethernet not installed
Description
The Ethernet Services option has to be installed when using remote
mounted disk.
Recommended actions
Reboot and install the Ethernet Services option.
71129, Too many remote disks
Description
The maximum number of remote mounted disks have been exceeded.
The maximum number is arg .
Recommended actions
Reduce the number of remote mounted disks.
71130, Too many remote servers
Description
The maximum number of servers for remote mounted disks have been
exceeded.
The maximum number is arg .
Recommended actions
1. Reduce the number of servers.
71131, Could not mount directory
Description
Mounting directory < arg > on the computer < arg > failed.
Protocol: < arg >.
Recommended actions
Check the server setup.
71139, Access error from I/O system
Description
Cannot read or write I/O signal < arg > due to communication down.
Recommended actions
Check 'No contact with I/O unit' report for more detailed information.
71141, Default value for I/O signal out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The default value is out of range.
This I/O signal has been rejected.
Recommended actions
Change the default value for the I/O signal.
71145, Interbus bus has been deactivated
Description
The Interbus bus has switched to a none running mode.
Recommended actions
Restart the system.
2. Check that correct Interbus boot project is selected.
71147, No response from the Interbus network
Description
Access to the Interbus network is denied.
Recommended actions
1. Check the Interbus board.
2. Check the internal Interbus configuration.
3. Reduce the cycle time on the slave I/O unit.
71148, No access to the Interbus network
Description
Access to the Interbus service interface is denied during arg , error code
is 0x arg .
Recommended actions
1. Check the internal Interbus configuration.
2. The Interbus may be faulty. Replace any faulty I/O unit if required.
71156, IPC queue full
Description
The interprocess communication (IPC) queue < arg > was full, when
sending to trap routine.
Recommended actions
Restart the system.
6 Trouble shooting by Event log
319
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71158, Address out of range
Description
The I/O configuration is invalid.
The address of I/O unit < arg > is invalid (out of range).
This I/O unit has been rejected.
Recommended actions
1. Change the address.
2. Check the address syntax.
71163, I/O signal on internal I/O unit
Description
The I/O configuration is invalid.
The user-defined I/O signal < arg > must not be connected to the
internal I/O unit < arg >
User defined I/O signals are not allowed to be connected to internal I/
O units.
This I/O signal has been rejected.
Recommended actions
Connect the I/O signal to another I/O unit.
71164, Internal I/O signal in cross connection
Description
The I/O configuration contains an invalid cross connection.
The <Actor argarg > is a user-defined I/O signal whereas the resultant
I/O signal < arg > is an internal I/O signal.
It is not allowed to define cross connections where user-defined I/O
signals affect internal I/O signals.
Recommended actions
Correct the cross connection so that there are no internal I/O signals in
the resultant expression.
71165, FTP server went down
Description
The connection to a non-trusted FTP server has been lost.
IP address: < arg >.
Recommended actions
Check cable and FTP server settings.
71166, FTP server went down
Description
The connection to a trusted FTP server has been lost.
IP address: < arg >.
Recommended actions
Check cable and FTP server settings.
71167, Wrong transmission protocol
Description
No matching transmission protocol was found in the configuration.
Recommended actions
Change the transmission protocol.
71169, Ethernet not installed
Description
The option Ethernet Services with FTP is not installed on this system.
Recommended actions
Reboot and install the Ethernet Services with FTP option.
71182, I/O signal undefined
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
contains a reference to an undefined I/O signal < arg >.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so that the resultant I/O signal refers to an
existing I/O signal.
71183, Cross connection with invalid operator
Description
The I/O configuration is invalid.
The parameter <Operator arg > of one of the cross connections
contains an invalid/unknown operator < arg >.
Valid values for the logical operator are:
- AND
- OR
This cross connection has been rejected.
Recommended actions
Correct the operator.
71185, Duplicated name
Description
The I/O configuration is invalid.
The identifier < arg > has already been used as the name of another
configuration instance.
The following configuration instances must have unique names:
- I/O Buses
- Unit types
- I/O Units
- I/O Signals
- Command types
- Commands
6 Trouble shooting by Event log
320
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- I/O Access levels
- CIP Routes
This configuration instance has been rejected.
Recommended actions
1. Rename one of the configuration instances in system parameters.
2. Restart the system.
71193, Invalid physical I/O mapping
Description
I/O mapping error on I/O unit < arg >.
Recommended actions
Check configuration for physical signal mapping.
71196, Invalid encoding type
Description
The I/O configuration for I/O signal < arg > is invalid.
The encoding type < arg > is not valid for signal type < arg >.
Valid encoding types are:
- UNSIGNED
- TWO_COMP
This I/O signal has been rejected.
Recommended actions
Correct the encoding type for the I/O signal.
71201, Unknown I/O bus
Description
The I/O configuration is invalid.
The I/O bus < arg > cannot be found in the system.
Installed I/O buses are: argargargarg
Consequences
This I/O bus has been rejected, and no functions depending on it will
work.
Recommended actions
1. Make sure the system has been configured with the desired I/O bus.
2. Make sure the I/O bus option at hand is installed.
3. Check the configuration for I/O bus.
71205, Could not mount directory
Description
Mounting directory < arg > on the computer < arg > failed.
Protocol: < arg >.
Recommended actions
1. Check the FTP server setup.
2. Check the FTP client configuration.
3. Check communication hardware, cabling.
71220, No Profibus option has been installed
Description
A Profibus-DP master/slave board has been fitted, but no Profibus
option has been installed.
Consequences
No communication on the Profibus is possible. There may be
consequential errors from configuring Profibus when no such option
has been installed.
Probable causes
An attempt may have been made to add the Profibus functionality,
without installing the option correctly.
Recommended actions
1. If the Profibus option is required: configure a new system with this
option, and install the system.
2. If the Profibus option is not required: configure a new system
without this option, and install the system.
71221, Profibus firmware file not found
Description
The Profibus < arg > firmware file not found or not readable.
The board firmware may be out of date.
Recommended actions
Reinstall the system.
71222, Profibus configuration file not found
Description
The binary Profibus configuration file was not found.
- File: < arg >
- Path: < arg >.
Recommended actions
1. Make sure the file exists.
2. Change the path in the I/O configuration.
71223, Profibus file parse error
Description
The binary Profibus configuration file is corrupt. (Internal error: arg )
- File: < arg >
- Path: < arg >.
Recommended actions
Recreate and download the binary configuration file using the external
Profibus configuration tool.
71224, Profibus channel has been reflashed
Description
The arg channel firmware of the Profibus board has been updated from
< arg > to < arg >.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 322
|
6 Trouble shooting by Event log
319
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71158, Address out of range
Description
The I/O configuration is invalid.
The address of I/O unit < arg > is invalid (out of range).
This I/O unit has been rejected.
Recommended actions
1. Change the address.
2. Check the address syntax.
71163, I/O signal on internal I/O unit
Description
The I/O configuration is invalid.
The user-defined I/O signal < arg > must not be connected to the
internal I/O unit < arg >
User defined I/O signals are not allowed to be connected to internal I/
O units.
This I/O signal has been rejected.
Recommended actions
Connect the I/O signal to another I/O unit.
71164, Internal I/O signal in cross connection
Description
The I/O configuration contains an invalid cross connection.
The <Actor argarg > is a user-defined I/O signal whereas the resultant
I/O signal < arg > is an internal I/O signal.
It is not allowed to define cross connections where user-defined I/O
signals affect internal I/O signals.
Recommended actions
Correct the cross connection so that there are no internal I/O signals in
the resultant expression.
71165, FTP server went down
Description
The connection to a non-trusted FTP server has been lost.
IP address: < arg >.
Recommended actions
Check cable and FTP server settings.
71166, FTP server went down
Description
The connection to a trusted FTP server has been lost.
IP address: < arg >.
Recommended actions
Check cable and FTP server settings.
71167, Wrong transmission protocol
Description
No matching transmission protocol was found in the configuration.
Recommended actions
Change the transmission protocol.
71169, Ethernet not installed
Description
The option Ethernet Services with FTP is not installed on this system.
Recommended actions
Reboot and install the Ethernet Services with FTP option.
71182, I/O signal undefined
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
contains a reference to an undefined I/O signal < arg >.
This cross connection has been rejected.
Recommended actions
Correct the cross connection so that the resultant I/O signal refers to an
existing I/O signal.
71183, Cross connection with invalid operator
Description
The I/O configuration is invalid.
The parameter <Operator arg > of one of the cross connections
contains an invalid/unknown operator < arg >.
Valid values for the logical operator are:
- AND
- OR
This cross connection has been rejected.
Recommended actions
Correct the operator.
71185, Duplicated name
Description
The I/O configuration is invalid.
The identifier < arg > has already been used as the name of another
configuration instance.
The following configuration instances must have unique names:
- I/O Buses
- Unit types
- I/O Units
- I/O Signals
- Command types
- Commands
6 Trouble shooting by Event log
320
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- I/O Access levels
- CIP Routes
This configuration instance has been rejected.
Recommended actions
1. Rename one of the configuration instances in system parameters.
2. Restart the system.
71193, Invalid physical I/O mapping
Description
I/O mapping error on I/O unit < arg >.
Recommended actions
Check configuration for physical signal mapping.
71196, Invalid encoding type
Description
The I/O configuration for I/O signal < arg > is invalid.
The encoding type < arg > is not valid for signal type < arg >.
Valid encoding types are:
- UNSIGNED
- TWO_COMP
This I/O signal has been rejected.
Recommended actions
Correct the encoding type for the I/O signal.
71201, Unknown I/O bus
Description
The I/O configuration is invalid.
The I/O bus < arg > cannot be found in the system.
Installed I/O buses are: argargargarg
Consequences
This I/O bus has been rejected, and no functions depending on it will
work.
Recommended actions
1. Make sure the system has been configured with the desired I/O bus.
2. Make sure the I/O bus option at hand is installed.
3. Check the configuration for I/O bus.
71205, Could not mount directory
Description
Mounting directory < arg > on the computer < arg > failed.
Protocol: < arg >.
Recommended actions
1. Check the FTP server setup.
2. Check the FTP client configuration.
3. Check communication hardware, cabling.
71220, No Profibus option has been installed
Description
A Profibus-DP master/slave board has been fitted, but no Profibus
option has been installed.
Consequences
No communication on the Profibus is possible. There may be
consequential errors from configuring Profibus when no such option
has been installed.
Probable causes
An attempt may have been made to add the Profibus functionality,
without installing the option correctly.
Recommended actions
1. If the Profibus option is required: configure a new system with this
option, and install the system.
2. If the Profibus option is not required: configure a new system
without this option, and install the system.
71221, Profibus firmware file not found
Description
The Profibus < arg > firmware file not found or not readable.
The board firmware may be out of date.
Recommended actions
Reinstall the system.
71222, Profibus configuration file not found
Description
The binary Profibus configuration file was not found.
- File: < arg >
- Path: < arg >.
Recommended actions
1. Make sure the file exists.
2. Change the path in the I/O configuration.
71223, Profibus file parse error
Description
The binary Profibus configuration file is corrupt. (Internal error: arg )
- File: < arg >
- Path: < arg >.
Recommended actions
Recreate and download the binary configuration file using the external
Profibus configuration tool.
71224, Profibus channel has been reflashed
Description
The arg channel firmware of the Profibus board has been updated from
< arg > to < arg >.
6 Trouble shooting by Event log
321
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71225, Profibus configuration error
Description
The local slave channel has more DI/DO than the configuration in its
master.
Recommended actions
Make the number of DI/DO of the external Profibus master more or
equal than the local slave.
71226, Profibus configuration ok
Description
The number of DI/DO of the external Profibus master is now more or
equal than for the I/O unit of DP_SLAVE type.
Recommended actions
71227, Initialization of Profibus slave failed
Description
The slave channel on the Profibus-DP master/slave board did not start
up correctly.
Consequences
No communication on the Profibus slave channel is possible.
Probable causes
The board hardware may be malfunctioning.
Recommended actions
1. Restart the system.
2. Replace the Profibus slave board if faulty.
71228, Profibus binary configuration fault
Description
The configuration data in the binary file is not accepted by the slave at
address < arg >.
Recommended actions
Make the configuration data in the binary file match the configuration
for the slave and reboot the system
71229, Profibus binary parameter fault
Description
The parameter data in the binary file is not accepted by the slave at
address < arg >.
Recommended actions
Make the parameter data in the binary file match the parameters for the
slave and reboot the system.
71230, I/O unit configuration error
Description
I/O unit < arg > is configured in system parameters but is missing or
incorrect in Profibus binary file.
Recommended actions
1. Check/change system parameters.
2. Check/change Profibus binary file.
71231, Wrong Profibus I/O unit is connected
Description
Profibus I/O unit < arg > at address < arg > has the wrong identity
number. Reported identity number is arg . Expected identity number is
arg .
Consequences
The system will not be able to Activate the I/O unit and no
communication on the Profibus will be possible.
Probable causes
-The I/O unit at address < arg > may be the wrong type of I/O unit.
-The configuration may be incorrect, i.e. an incorrect binary
configuration file and in some cases incorrect system parameters.
Recommended actions
1. Make sure the system parameters are correct.
2. Make sure the Profibus binary file is correct.
3. Replace the I/O unit.
71232, Too many internal Profibus slaves
Description
There are too many internal Profibus slaves defined in the system.
Consequences
Profibus I/O unit < arg > will not be configured. No communication
with this unit
will be possible.
Probable causes
Profibus I/O unit < arg > is defined as an internal slave while another
internal slave has already been configured.
The maximum number of internal slaves is 1.
Recommended actions
1. Make sure the system parameters are correct.
2. Make sure the Profibus binary file is correct.
71241, Too many I/O units on I/O bus
Description
The I/O configuration for I/O unit < arg > is invalid.
The number of I/O units on I/O bus < arg > must not exceed arg .
This I/O unit has been rejected.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 323
|
6 Trouble shooting by Event log
320
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- I/O Access levels
- CIP Routes
This configuration instance has been rejected.
Recommended actions
1. Rename one of the configuration instances in system parameters.
2. Restart the system.
71193, Invalid physical I/O mapping
Description
I/O mapping error on I/O unit < arg >.
Recommended actions
Check configuration for physical signal mapping.
71196, Invalid encoding type
Description
The I/O configuration for I/O signal < arg > is invalid.
The encoding type < arg > is not valid for signal type < arg >.
Valid encoding types are:
- UNSIGNED
- TWO_COMP
This I/O signal has been rejected.
Recommended actions
Correct the encoding type for the I/O signal.
71201, Unknown I/O bus
Description
The I/O configuration is invalid.
The I/O bus < arg > cannot be found in the system.
Installed I/O buses are: argargargarg
Consequences
This I/O bus has been rejected, and no functions depending on it will
work.
Recommended actions
1. Make sure the system has been configured with the desired I/O bus.
2. Make sure the I/O bus option at hand is installed.
3. Check the configuration for I/O bus.
71205, Could not mount directory
Description
Mounting directory < arg > on the computer < arg > failed.
Protocol: < arg >.
Recommended actions
1. Check the FTP server setup.
2. Check the FTP client configuration.
3. Check communication hardware, cabling.
71220, No Profibus option has been installed
Description
A Profibus-DP master/slave board has been fitted, but no Profibus
option has been installed.
Consequences
No communication on the Profibus is possible. There may be
consequential errors from configuring Profibus when no such option
has been installed.
Probable causes
An attempt may have been made to add the Profibus functionality,
without installing the option correctly.
Recommended actions
1. If the Profibus option is required: configure a new system with this
option, and install the system.
2. If the Profibus option is not required: configure a new system
without this option, and install the system.
71221, Profibus firmware file not found
Description
The Profibus < arg > firmware file not found or not readable.
The board firmware may be out of date.
Recommended actions
Reinstall the system.
71222, Profibus configuration file not found
Description
The binary Profibus configuration file was not found.
- File: < arg >
- Path: < arg >.
Recommended actions
1. Make sure the file exists.
2. Change the path in the I/O configuration.
71223, Profibus file parse error
Description
The binary Profibus configuration file is corrupt. (Internal error: arg )
- File: < arg >
- Path: < arg >.
Recommended actions
Recreate and download the binary configuration file using the external
Profibus configuration tool.
71224, Profibus channel has been reflashed
Description
The arg channel firmware of the Profibus board has been updated from
< arg > to < arg >.
6 Trouble shooting by Event log
321
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71225, Profibus configuration error
Description
The local slave channel has more DI/DO than the configuration in its
master.
Recommended actions
Make the number of DI/DO of the external Profibus master more or
equal than the local slave.
71226, Profibus configuration ok
Description
The number of DI/DO of the external Profibus master is now more or
equal than for the I/O unit of DP_SLAVE type.
Recommended actions
71227, Initialization of Profibus slave failed
Description
The slave channel on the Profibus-DP master/slave board did not start
up correctly.
Consequences
No communication on the Profibus slave channel is possible.
Probable causes
The board hardware may be malfunctioning.
Recommended actions
1. Restart the system.
2. Replace the Profibus slave board if faulty.
71228, Profibus binary configuration fault
Description
The configuration data in the binary file is not accepted by the slave at
address < arg >.
Recommended actions
Make the configuration data in the binary file match the configuration
for the slave and reboot the system
71229, Profibus binary parameter fault
Description
The parameter data in the binary file is not accepted by the slave at
address < arg >.
Recommended actions
Make the parameter data in the binary file match the parameters for the
slave and reboot the system.
71230, I/O unit configuration error
Description
I/O unit < arg > is configured in system parameters but is missing or
incorrect in Profibus binary file.
Recommended actions
1. Check/change system parameters.
2. Check/change Profibus binary file.
71231, Wrong Profibus I/O unit is connected
Description
Profibus I/O unit < arg > at address < arg > has the wrong identity
number. Reported identity number is arg . Expected identity number is
arg .
Consequences
The system will not be able to Activate the I/O unit and no
communication on the Profibus will be possible.
Probable causes
-The I/O unit at address < arg > may be the wrong type of I/O unit.
-The configuration may be incorrect, i.e. an incorrect binary
configuration file and in some cases incorrect system parameters.
Recommended actions
1. Make sure the system parameters are correct.
2. Make sure the Profibus binary file is correct.
3. Replace the I/O unit.
71232, Too many internal Profibus slaves
Description
There are too many internal Profibus slaves defined in the system.
Consequences
Profibus I/O unit < arg > will not be configured. No communication
with this unit
will be possible.
Probable causes
Profibus I/O unit < arg > is defined as an internal slave while another
internal slave has already been configured.
The maximum number of internal slaves is 1.
Recommended actions
1. Make sure the system parameters are correct.
2. Make sure the Profibus binary file is correct.
71241, Too many I/O units on I/O bus
Description
The I/O configuration for I/O unit < arg > is invalid.
The number of I/O units on I/O bus < arg > must not exceed arg .
This I/O unit has been rejected.
6 Trouble shooting by Event log
322
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reduce the number of defined I/O units and reboot the system.
71244, Incorrect Interbus unit type
Description
I/O unit < arg > at address < arg > has a unit type not supported by the
system.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
One or more of the units connected to the network is of a hardware
version not supported by the system.
Recommended actions
1. Replace the unsupported I/O unit with one of the correct version.
2. Make sure the system parameters are correct.
3. Reconfigure the Interbus network.
71245, I/O unit not defined in Interbus
configuration
Description
I/O unit < arg . arg > is not assigned to any address in the Interbus
configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
Data for defining the I/O unit is missing in the Interbus configuration.
Recommended actions
Change the Interbus configuration using the CMD tool under the
Process Data menu. Add an address for the I/O unit. The CMD tool is
available from your local ABB representative.
71246, No access to Interbus data
Description
Access to the Interbus board data interface is denied. arg not
performed, error code arg .
Recommended actions
1. The Interbus board may be faulty. Replace any faulty boards if
required.
2. Check the Interbus internal configuration.
71248, Interbus I/O unit configuration mismatch
Description
The Interbus I/O unit with address < arg > is configured in the system
parameters, but not in the Interbus configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
The Interbus unit address in the Interbus configuration differs from
that in the system parameters, or the I/O unit may not have been
configured at all in the Interbus configuration.
Recommended actions
1. Make sure system parameters are correct.
2. Reconfigure the Interbus network.
71249, Interbus I/O unit configuration mismatch
Description
The Interbus I/O unit with address < arg . arg > is configured in the
Interbus configuration, but not in the system parameters.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
The Interbus unit address in the Interbus configuration differs from
that in the system parameters, or the I/O unit may not have been
configured at all in the system parameters.
Recommended actions
1. Make sure system parameters are correct.
2. Reconfigure the Interbus network.
71250, Cannot configure Interbus board
Description
An error has occurred when downloading Interbus configuration file to
the Interbus board. Interbus specific error code: arg .
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Probable causes
The path specifying the Interbus configuration files points out the
wrong files or that configuration file is incorrect.
Recommended actions
1. Use RobotStudio to check the path to the configuration files.
2. Make sure the configuration files are correct.
3. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71258, Interbus configuration file not found
Description
The Interbus configuration file < arg >, configured in the system
parameters, was not found.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 324
|
6 Trouble shooting by Event log
321
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71225, Profibus configuration error
Description
The local slave channel has more DI/DO than the configuration in its
master.
Recommended actions
Make the number of DI/DO of the external Profibus master more or
equal than the local slave.
71226, Profibus configuration ok
Description
The number of DI/DO of the external Profibus master is now more or
equal than for the I/O unit of DP_SLAVE type.
Recommended actions
71227, Initialization of Profibus slave failed
Description
The slave channel on the Profibus-DP master/slave board did not start
up correctly.
Consequences
No communication on the Profibus slave channel is possible.
Probable causes
The board hardware may be malfunctioning.
Recommended actions
1. Restart the system.
2. Replace the Profibus slave board if faulty.
71228, Profibus binary configuration fault
Description
The configuration data in the binary file is not accepted by the slave at
address < arg >.
Recommended actions
Make the configuration data in the binary file match the configuration
for the slave and reboot the system
71229, Profibus binary parameter fault
Description
The parameter data in the binary file is not accepted by the slave at
address < arg >.
Recommended actions
Make the parameter data in the binary file match the parameters for the
slave and reboot the system.
71230, I/O unit configuration error
Description
I/O unit < arg > is configured in system parameters but is missing or
incorrect in Profibus binary file.
Recommended actions
1. Check/change system parameters.
2. Check/change Profibus binary file.
71231, Wrong Profibus I/O unit is connected
Description
Profibus I/O unit < arg > at address < arg > has the wrong identity
number. Reported identity number is arg . Expected identity number is
arg .
Consequences
The system will not be able to Activate the I/O unit and no
communication on the Profibus will be possible.
Probable causes
-The I/O unit at address < arg > may be the wrong type of I/O unit.
-The configuration may be incorrect, i.e. an incorrect binary
configuration file and in some cases incorrect system parameters.
Recommended actions
1. Make sure the system parameters are correct.
2. Make sure the Profibus binary file is correct.
3. Replace the I/O unit.
71232, Too many internal Profibus slaves
Description
There are too many internal Profibus slaves defined in the system.
Consequences
Profibus I/O unit < arg > will not be configured. No communication
with this unit
will be possible.
Probable causes
Profibus I/O unit < arg > is defined as an internal slave while another
internal slave has already been configured.
The maximum number of internal slaves is 1.
Recommended actions
1. Make sure the system parameters are correct.
2. Make sure the Profibus binary file is correct.
71241, Too many I/O units on I/O bus
Description
The I/O configuration for I/O unit < arg > is invalid.
The number of I/O units on I/O bus < arg > must not exceed arg .
This I/O unit has been rejected.
6 Trouble shooting by Event log
322
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reduce the number of defined I/O units and reboot the system.
71244, Incorrect Interbus unit type
Description
I/O unit < arg > at address < arg > has a unit type not supported by the
system.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
One or more of the units connected to the network is of a hardware
version not supported by the system.
Recommended actions
1. Replace the unsupported I/O unit with one of the correct version.
2. Make sure the system parameters are correct.
3. Reconfigure the Interbus network.
71245, I/O unit not defined in Interbus
configuration
Description
I/O unit < arg . arg > is not assigned to any address in the Interbus
configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
Data for defining the I/O unit is missing in the Interbus configuration.
Recommended actions
Change the Interbus configuration using the CMD tool under the
Process Data menu. Add an address for the I/O unit. The CMD tool is
available from your local ABB representative.
71246, No access to Interbus data
Description
Access to the Interbus board data interface is denied. arg not
performed, error code arg .
Recommended actions
1. The Interbus board may be faulty. Replace any faulty boards if
required.
2. Check the Interbus internal configuration.
71248, Interbus I/O unit configuration mismatch
Description
The Interbus I/O unit with address < arg > is configured in the system
parameters, but not in the Interbus configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
The Interbus unit address in the Interbus configuration differs from
that in the system parameters, or the I/O unit may not have been
configured at all in the Interbus configuration.
Recommended actions
1. Make sure system parameters are correct.
2. Reconfigure the Interbus network.
71249, Interbus I/O unit configuration mismatch
Description
The Interbus I/O unit with address < arg . arg > is configured in the
Interbus configuration, but not in the system parameters.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
The Interbus unit address in the Interbus configuration differs from
that in the system parameters, or the I/O unit may not have been
configured at all in the system parameters.
Recommended actions
1. Make sure system parameters are correct.
2. Reconfigure the Interbus network.
71250, Cannot configure Interbus board
Description
An error has occurred when downloading Interbus configuration file to
the Interbus board. Interbus specific error code: arg .
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Probable causes
The path specifying the Interbus configuration files points out the
wrong files or that configuration file is incorrect.
Recommended actions
1. Use RobotStudio to check the path to the configuration files.
2. Make sure the configuration files are correct.
3. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71258, Interbus configuration file not found
Description
The Interbus configuration file < arg >, configured in the system
parameters, was not found.
6 Trouble shooting by Event log
323
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Probable causes
The Interbus configuration file does not exist or the path specified in
the system parameters was incorrect.
Recommended actions
1. Make sure the Interbus configuration files are correctly located.
2. Use RobotStudio to check the path to the configuration files.
71259, Cannot read the Interbus configuration
file
Description
An error occurred when attempting to read the Interbus board
configuration file < arg >.
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Recommended actions
1. Reload the Interbus configuration file to the robot controller.
2. Restart the system.
71260, Interbus bus failure
Description
The control system has lost communication with the Interbus network.
Interbus specific error code: arg .
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure all communication cables and connectors are working
correctly and of the recommended type
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71261, Transport layer failure
Description
The physical channel for transport layer arg is invalid.
Recommended actions
Verify that the physical channel is valid, see manual.
71273, I/O unit configuration mismatch
Description
I/O unit < arg > is configured in the system parameters, but it cannot be
found in the I/O bus specific configuration.
Probable causes
1. The address of the I/O unit in the system parameters are not the same
as in the I/O bus specific configuration.
2. The I/O unit has not been configured at all in the I/O bus specific
configuration.
Recommended actions
1. Check I/O unit configuration in system parameters
2. Check I/O bus specific configuration
71274, Interbus bus failure
Description
The control system was unable to determine the bus operating mode of
the Interbus board.
Recommended actions
Restart the system.
71276, Communication established with I/O unit
Description
Communication established with I/O unit < arg >.
71278, Mount permission denied
Description
Permission was denied to mount the directory < arg > on the server
< arg >.
Recommended actions
Check the username and password.
71288, Mount path is too large
Description
Mount path is too large. Mount path consists of FTP server mount
point and server path.
- Max length: < arg >
- Protocol used: < arg >
Recommended actions
Change FTP server mount point or server path.
71289, Memory partition is too big
Description
The memory partition for communication purposes cannot be
allocated. The requested partition arg kB. System partition will be
used.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 325
|
6 Trouble shooting by Event log
322
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reduce the number of defined I/O units and reboot the system.
71244, Incorrect Interbus unit type
Description
I/O unit < arg > at address < arg > has a unit type not supported by the
system.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
One or more of the units connected to the network is of a hardware
version not supported by the system.
Recommended actions
1. Replace the unsupported I/O unit with one of the correct version.
2. Make sure the system parameters are correct.
3. Reconfigure the Interbus network.
71245, I/O unit not defined in Interbus
configuration
Description
I/O unit < arg . arg > is not assigned to any address in the Interbus
configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
Data for defining the I/O unit is missing in the Interbus configuration.
Recommended actions
Change the Interbus configuration using the CMD tool under the
Process Data menu. Add an address for the I/O unit. The CMD tool is
available from your local ABB representative.
71246, No access to Interbus data
Description
Access to the Interbus board data interface is denied. arg not
performed, error code arg .
Recommended actions
1. The Interbus board may be faulty. Replace any faulty boards if
required.
2. Check the Interbus internal configuration.
71248, Interbus I/O unit configuration mismatch
Description
The Interbus I/O unit with address < arg > is configured in the system
parameters, but not in the Interbus configuration.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
The Interbus unit address in the Interbus configuration differs from
that in the system parameters, or the I/O unit may not have been
configured at all in the Interbus configuration.
Recommended actions
1. Make sure system parameters are correct.
2. Reconfigure the Interbus network.
71249, Interbus I/O unit configuration mismatch
Description
The Interbus I/O unit with address < arg . arg > is configured in the
Interbus configuration, but not in the system parameters.
Consequences
The I/O unit has not been configured, and cannot be used by the
system.
Probable causes
The Interbus unit address in the Interbus configuration differs from
that in the system parameters, or the I/O unit may not have been
configured at all in the system parameters.
Recommended actions
1. Make sure system parameters are correct.
2. Reconfigure the Interbus network.
71250, Cannot configure Interbus board
Description
An error has occurred when downloading Interbus configuration file to
the Interbus board. Interbus specific error code: arg .
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Probable causes
The path specifying the Interbus configuration files points out the
wrong files or that configuration file is incorrect.
Recommended actions
1. Use RobotStudio to check the path to the configuration files.
2. Make sure the configuration files are correct.
3. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71258, Interbus configuration file not found
Description
The Interbus configuration file < arg >, configured in the system
parameters, was not found.
6 Trouble shooting by Event log
323
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Probable causes
The Interbus configuration file does not exist or the path specified in
the system parameters was incorrect.
Recommended actions
1. Make sure the Interbus configuration files are correctly located.
2. Use RobotStudio to check the path to the configuration files.
71259, Cannot read the Interbus configuration
file
Description
An error occurred when attempting to read the Interbus board
configuration file < arg >.
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Recommended actions
1. Reload the Interbus configuration file to the robot controller.
2. Restart the system.
71260, Interbus bus failure
Description
The control system has lost communication with the Interbus network.
Interbus specific error code: arg .
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure all communication cables and connectors are working
correctly and of the recommended type
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71261, Transport layer failure
Description
The physical channel for transport layer arg is invalid.
Recommended actions
Verify that the physical channel is valid, see manual.
71273, I/O unit configuration mismatch
Description
I/O unit < arg > is configured in the system parameters, but it cannot be
found in the I/O bus specific configuration.
Probable causes
1. The address of the I/O unit in the system parameters are not the same
as in the I/O bus specific configuration.
2. The I/O unit has not been configured at all in the I/O bus specific
configuration.
Recommended actions
1. Check I/O unit configuration in system parameters
2. Check I/O bus specific configuration
71274, Interbus bus failure
Description
The control system was unable to determine the bus operating mode of
the Interbus board.
Recommended actions
Restart the system.
71276, Communication established with I/O unit
Description
Communication established with I/O unit < arg >.
71278, Mount permission denied
Description
Permission was denied to mount the directory < arg > on the server
< arg >.
Recommended actions
Check the username and password.
71288, Mount path is too large
Description
Mount path is too large. Mount path consists of FTP server mount
point and server path.
- Max length: < arg >
- Protocol used: < arg >
Recommended actions
Change FTP server mount point or server path.
71289, Memory partition is too big
Description
The memory partition for communication purposes cannot be
allocated. The requested partition arg kB. System partition will be
used.
6 Trouble shooting by Event log
324
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Decrease commPartSize.
71290, Could not add FTP device
Description
Adding the FTP device < arg > to the operating system failed.
Application protocol < arg >.
Recommended actions
Change the local path of the configuration of the FTP device.
71291, Invalid local path
Description
Local path of the FTP device < arg > is invalid.
Recommended actions
Local path must end with :
71293, Invalid input size
Description
On DeviceNet I/O unit < arg > the connection 1 input size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type
71294, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 1 output size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type
71295, Invalid input size
Description
On DeviceNet I/O unit < arg > the connection 2 input size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
71296, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 2 output size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
71297, Invalid connection type
Description
The DeviceNet I/O unit < arg > does not support arg connection.
Recommended actions
1. Change connection 1 type and/or connection 2 type in configuration.
2. Use DN_GENERIC unit type.
71298, Duplicated address
Description
The address < arg > for the DeviceNet master on I/O bus < arg > is
occupied by another I/O unit on the network.
Recommended actions
1. Change master address in configuration.
2. Disconnect I/O unit occupying the address from the network.
3. Restart the system.
71299, No power on DeviceNet bus
Description
The 24 V power supply from the DeviceNet power supply is missing.
Consequences
No communication on the DeviceNet bus < arg > is possible.
Probable causes
The power supply unit, cabling, input voltage to the power supply or
the output load may cause the power loss. See the Trouble Shooting
Manual and Circuit Diagram!
Recommended actions
1. Check all cabling to the power supply unit.
2. Measure the output and input voltage levels.
3. Replace the faulty I/O unit if required.
71300, DeviceNet bus communication warning
Description
A minor number of communication errors occurred on DeviceNet bus
< arg >.
Consequences
Normal operation will be maintained, even on the DeviceNet.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 326
|
6 Trouble shooting by Event log
323
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Probable causes
The Interbus configuration file does not exist or the path specified in
the system parameters was incorrect.
Recommended actions
1. Make sure the Interbus configuration files are correctly located.
2. Use RobotStudio to check the path to the configuration files.
71259, Cannot read the Interbus configuration
file
Description
An error occurred when attempting to read the Interbus board
configuration file < arg >.
Consequences
The I/O bus has not been configured, and cannot be used by the system.
Recommended actions
1. Reload the Interbus configuration file to the robot controller.
2. Restart the system.
71260, Interbus bus failure
Description
The control system has lost communication with the Interbus network.
Interbus specific error code: arg .
Consequences
Parts of the Interbus network will not be accessible, depending on the
network topology and the nature of the fault.
Probable causes
A number of errors may cause this. Further information may be found
in the standard Interbus documentation.
Recommended actions
1. Make sure all communication cables and connectors are working
correctly and of the recommended type
2. Check the Interbus specific error code as specified in the Interbus
Manuals: Firmware Service and Error Messages.
71261, Transport layer failure
Description
The physical channel for transport layer arg is invalid.
Recommended actions
Verify that the physical channel is valid, see manual.
71273, I/O unit configuration mismatch
Description
I/O unit < arg > is configured in the system parameters, but it cannot be
found in the I/O bus specific configuration.
Probable causes
1. The address of the I/O unit in the system parameters are not the same
as in the I/O bus specific configuration.
2. The I/O unit has not been configured at all in the I/O bus specific
configuration.
Recommended actions
1. Check I/O unit configuration in system parameters
2. Check I/O bus specific configuration
71274, Interbus bus failure
Description
The control system was unable to determine the bus operating mode of
the Interbus board.
Recommended actions
Restart the system.
71276, Communication established with I/O unit
Description
Communication established with I/O unit < arg >.
71278, Mount permission denied
Description
Permission was denied to mount the directory < arg > on the server
< arg >.
Recommended actions
Check the username and password.
71288, Mount path is too large
Description
Mount path is too large. Mount path consists of FTP server mount
point and server path.
- Max length: < arg >
- Protocol used: < arg >
Recommended actions
Change FTP server mount point or server path.
71289, Memory partition is too big
Description
The memory partition for communication purposes cannot be
allocated. The requested partition arg kB. System partition will be
used.
6 Trouble shooting by Event log
324
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Decrease commPartSize.
71290, Could not add FTP device
Description
Adding the FTP device < arg > to the operating system failed.
Application protocol < arg >.
Recommended actions
Change the local path of the configuration of the FTP device.
71291, Invalid local path
Description
Local path of the FTP device < arg > is invalid.
Recommended actions
Local path must end with :
71293, Invalid input size
Description
On DeviceNet I/O unit < arg > the connection 1 input size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type
71294, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 1 output size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type
71295, Invalid input size
Description
On DeviceNet I/O unit < arg > the connection 2 input size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
71296, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 2 output size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
71297, Invalid connection type
Description
The DeviceNet I/O unit < arg > does not support arg connection.
Recommended actions
1. Change connection 1 type and/or connection 2 type in configuration.
2. Use DN_GENERIC unit type.
71298, Duplicated address
Description
The address < arg > for the DeviceNet master on I/O bus < arg > is
occupied by another I/O unit on the network.
Recommended actions
1. Change master address in configuration.
2. Disconnect I/O unit occupying the address from the network.
3. Restart the system.
71299, No power on DeviceNet bus
Description
The 24 V power supply from the DeviceNet power supply is missing.
Consequences
No communication on the DeviceNet bus < arg > is possible.
Probable causes
The power supply unit, cabling, input voltage to the power supply or
the output load may cause the power loss. See the Trouble Shooting
Manual and Circuit Diagram!
Recommended actions
1. Check all cabling to the power supply unit.
2. Measure the output and input voltage levels.
3. Replace the faulty I/O unit if required.
71300, DeviceNet bus communication warning
Description
A minor number of communication errors occurred on DeviceNet bus
< arg >.
Consequences
Normal operation will be maintained, even on the DeviceNet.
6 Trouble shooting by Event log
325
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The fault may be caused by interference, power supply units and
cables, or communication cables.
Recommended actions
1. Make sure any terminating resistors are correctly connected.
2. Make sure all communication cables and connectors are working
correctly and of the recommended type.
3. Check network topology and cable length.
4. Make sure the DeviceNet Power Supply unit is working correctly.
Replace any faulty unit.
71301, Bus off, DeviceNet bus communication
failure
Description
A major number of communication errors occurred on DeviceNet bus
< arg >.
Consequences
All communication on the DeviceNet Bus has stopped.
Probable causes
The fault may be caused by interference, power supply units and
cables, or communication cables.
Recommended actions
1. Make sure the DeviceNet Power Supply unit is working correctly.
Replace any faulty I/O unit.
2. Make sure any terminating resistors are correctly connected.
3. Make sure all communication cables and connectors are working
correctly and of the recommended type.
4. Check network topology and cable length.
5. Restart the system.
71302, No DeviceNet option has been installed
Description
A DeviceNet master/slave board has been fitted, but no DeviceNet
option has been installed.
Consequences
No communication on the DeviceNet is possible. There may be
consequential errors from configuring DeviceNet when no such option
has been installed.
Probable causes
An attempt may have been made to add the DeviceNet functionality,
without installing the option correctly.
Recommended actions
1. If the DeviceNet option is required: configure a new system with this
option, and install the system.
2. If the DeviceNet option is not required: configure a new system
without this option, and install the system.
71303, Invalid DeviceNet vendor id
Description
The vendor id read from DeviceNet I/O unit < arg > doesn't match value
in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change vendor id in configuration.
2. Check that the type of I/O unit is correct.
71304, Invalid DeviceNet device type
Description
The device type read from DeviceNet I/O unit < arg > doesn't match
value in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change device type in configuration.
2. Check that the type of I/O unit is correct.
71305, Invalid DeviceNet product code
Description
The product code read from DeviceNet I/O unit < arg > doesn't match
value in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change product code in configuration.
2. Check that the type of I/O unit is correct.
71306, DeviceNet unknown error
Description
An unknown error is reported from I/O unit < arg > error code arg .
Recommended actions
1. Restart the system.
2. Report problem to ABB.
71307, DeviceNet generic connection 1
Description
On DeviceNet I/O unit < arg > connection 1 configuration are generic.
Real values:
- Connection 1 type: < arg >
- Connection 1 input size: < arg >
- Connection 1 output size: < arg >
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 327
|
6 Trouble shooting by Event log
324
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Decrease commPartSize.
71290, Could not add FTP device
Description
Adding the FTP device < arg > to the operating system failed.
Application protocol < arg >.
Recommended actions
Change the local path of the configuration of the FTP device.
71291, Invalid local path
Description
Local path of the FTP device < arg > is invalid.
Recommended actions
Local path must end with :
71293, Invalid input size
Description
On DeviceNet I/O unit < arg > the connection 1 input size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type
71294, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 1 output size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type
71295, Invalid input size
Description
On DeviceNet I/O unit < arg > the connection 2 input size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
71296, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 2 output size does not
match the I/O unit.
Recommended actions
1. Change size in configuration.
2. Check module.
71297, Invalid connection type
Description
The DeviceNet I/O unit < arg > does not support arg connection.
Recommended actions
1. Change connection 1 type and/or connection 2 type in configuration.
2. Use DN_GENERIC unit type.
71298, Duplicated address
Description
The address < arg > for the DeviceNet master on I/O bus < arg > is
occupied by another I/O unit on the network.
Recommended actions
1. Change master address in configuration.
2. Disconnect I/O unit occupying the address from the network.
3. Restart the system.
71299, No power on DeviceNet bus
Description
The 24 V power supply from the DeviceNet power supply is missing.
Consequences
No communication on the DeviceNet bus < arg > is possible.
Probable causes
The power supply unit, cabling, input voltage to the power supply or
the output load may cause the power loss. See the Trouble Shooting
Manual and Circuit Diagram!
Recommended actions
1. Check all cabling to the power supply unit.
2. Measure the output and input voltage levels.
3. Replace the faulty I/O unit if required.
71300, DeviceNet bus communication warning
Description
A minor number of communication errors occurred on DeviceNet bus
< arg >.
Consequences
Normal operation will be maintained, even on the DeviceNet.
6 Trouble shooting by Event log
325
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The fault may be caused by interference, power supply units and
cables, or communication cables.
Recommended actions
1. Make sure any terminating resistors are correctly connected.
2. Make sure all communication cables and connectors are working
correctly and of the recommended type.
3. Check network topology and cable length.
4. Make sure the DeviceNet Power Supply unit is working correctly.
Replace any faulty unit.
71301, Bus off, DeviceNet bus communication
failure
Description
A major number of communication errors occurred on DeviceNet bus
< arg >.
Consequences
All communication on the DeviceNet Bus has stopped.
Probable causes
The fault may be caused by interference, power supply units and
cables, or communication cables.
Recommended actions
1. Make sure the DeviceNet Power Supply unit is working correctly.
Replace any faulty I/O unit.
2. Make sure any terminating resistors are correctly connected.
3. Make sure all communication cables and connectors are working
correctly and of the recommended type.
4. Check network topology and cable length.
5. Restart the system.
71302, No DeviceNet option has been installed
Description
A DeviceNet master/slave board has been fitted, but no DeviceNet
option has been installed.
Consequences
No communication on the DeviceNet is possible. There may be
consequential errors from configuring DeviceNet when no such option
has been installed.
Probable causes
An attempt may have been made to add the DeviceNet functionality,
without installing the option correctly.
Recommended actions
1. If the DeviceNet option is required: configure a new system with this
option, and install the system.
2. If the DeviceNet option is not required: configure a new system
without this option, and install the system.
71303, Invalid DeviceNet vendor id
Description
The vendor id read from DeviceNet I/O unit < arg > doesn't match value
in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change vendor id in configuration.
2. Check that the type of I/O unit is correct.
71304, Invalid DeviceNet device type
Description
The device type read from DeviceNet I/O unit < arg > doesn't match
value in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change device type in configuration.
2. Check that the type of I/O unit is correct.
71305, Invalid DeviceNet product code
Description
The product code read from DeviceNet I/O unit < arg > doesn't match
value in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change product code in configuration.
2. Check that the type of I/O unit is correct.
71306, DeviceNet unknown error
Description
An unknown error is reported from I/O unit < arg > error code arg .
Recommended actions
1. Restart the system.
2. Report problem to ABB.
71307, DeviceNet generic connection 1
Description
On DeviceNet I/O unit < arg > connection 1 configuration are generic.
Real values:
- Connection 1 type: < arg >
- Connection 1 input size: < arg >
- Connection 1 output size: < arg >
6 Trouble shooting by Event log
326
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71308, DeviceNet generic connection 2
Description
On DeviceNet I/O unit < arg > connection 2 configuration are generic.
Real values:
- Connection 2 type: < arg >
- Connection 2 input size: < arg >
- Connection 2 output size: < arg >
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71309, DeviceNet generic unit identification
Description
On DeviceNet I/O unit < arg > identity configuration are generic.
Real values:
- Vendor Id: < arg >
- Product code: < arg >
- Device type: < arg >
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71310, DeviceNet I/O unit connection error
Description
DeviceNet I/O unit < arg > is occupied by another master.
Recommended actions
1. Check configuration.
2. Cycle power on I/O unit.
71311, Unable to established communication
on DeviceNet bus
Description
Unable to established communication on DeviceNet bus < arg >
because no I/O units are physically connected.
Recommended actions
1. Check cables and connectors.
2. Connect I/O units to I/O bus.
3. Restart the system.
4. Remove I/O units on the I/O bus < arg > from the configuration.
71312, DeviceNet I/O unit explicit connection
not enabled
Description
DeviceNet I/O unit < arg > does not have the explicit message
connection enabled.
Recommended actions
Change configuration.
71313, Fieldbus command type order number
not unique.
Description
The I/O configuration is invalid.
Fieldbus command < arg > and < arg > are connected to the same unit
type < arg > and have the same order number < arg >.
The order number of commands connected to the same I/O unit must
be unique.
This command has been rejected.
Recommended actions
Correct the configuration.
71314, Invalid fieldbus command type
Description
The I/O configuration is invalid.
One of the fieldbus commands has a reference to an invalid/unknown
command type < arg >.
All fieldbus commands must refer to an existing command type.
This fieldbus command has been rejected.
Recommended actions
Correct the fieldbus command type for the command.
71315, Max number of fieldbus commands
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of fieldbus commands in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
fieldbus commands) so that the maximum limit is not exceeded.
71316, Max number of fieldbus command types
exceeded
Description
The I/O configuration is invalid.
The maximum number arg , of fieldbus command types in the I/O
system has been exceeded.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 328
|
6 Trouble shooting by Event log
325
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The fault may be caused by interference, power supply units and
cables, or communication cables.
Recommended actions
1. Make sure any terminating resistors are correctly connected.
2. Make sure all communication cables and connectors are working
correctly and of the recommended type.
3. Check network topology and cable length.
4. Make sure the DeviceNet Power Supply unit is working correctly.
Replace any faulty unit.
71301, Bus off, DeviceNet bus communication
failure
Description
A major number of communication errors occurred on DeviceNet bus
< arg >.
Consequences
All communication on the DeviceNet Bus has stopped.
Probable causes
The fault may be caused by interference, power supply units and
cables, or communication cables.
Recommended actions
1. Make sure the DeviceNet Power Supply unit is working correctly.
Replace any faulty I/O unit.
2. Make sure any terminating resistors are correctly connected.
3. Make sure all communication cables and connectors are working
correctly and of the recommended type.
4. Check network topology and cable length.
5. Restart the system.
71302, No DeviceNet option has been installed
Description
A DeviceNet master/slave board has been fitted, but no DeviceNet
option has been installed.
Consequences
No communication on the DeviceNet is possible. There may be
consequential errors from configuring DeviceNet when no such option
has been installed.
Probable causes
An attempt may have been made to add the DeviceNet functionality,
without installing the option correctly.
Recommended actions
1. If the DeviceNet option is required: configure a new system with this
option, and install the system.
2. If the DeviceNet option is not required: configure a new system
without this option, and install the system.
71303, Invalid DeviceNet vendor id
Description
The vendor id read from DeviceNet I/O unit < arg > doesn't match value
in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change vendor id in configuration.
2. Check that the type of I/O unit is correct.
71304, Invalid DeviceNet device type
Description
The device type read from DeviceNet I/O unit < arg > doesn't match
value in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change device type in configuration.
2. Check that the type of I/O unit is correct.
71305, Invalid DeviceNet product code
Description
The product code read from DeviceNet I/O unit < arg > doesn't match
value in unit type configuration.
- Configuration: < arg >
- Actual: < arg >
Recommended actions
1. Change product code in configuration.
2. Check that the type of I/O unit is correct.
71306, DeviceNet unknown error
Description
An unknown error is reported from I/O unit < arg > error code arg .
Recommended actions
1. Restart the system.
2. Report problem to ABB.
71307, DeviceNet generic connection 1
Description
On DeviceNet I/O unit < arg > connection 1 configuration are generic.
Real values:
- Connection 1 type: < arg >
- Connection 1 input size: < arg >
- Connection 1 output size: < arg >
6 Trouble shooting by Event log
326
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71308, DeviceNet generic connection 2
Description
On DeviceNet I/O unit < arg > connection 2 configuration are generic.
Real values:
- Connection 2 type: < arg >
- Connection 2 input size: < arg >
- Connection 2 output size: < arg >
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71309, DeviceNet generic unit identification
Description
On DeviceNet I/O unit < arg > identity configuration are generic.
Real values:
- Vendor Id: < arg >
- Product code: < arg >
- Device type: < arg >
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71310, DeviceNet I/O unit connection error
Description
DeviceNet I/O unit < arg > is occupied by another master.
Recommended actions
1. Check configuration.
2. Cycle power on I/O unit.
71311, Unable to established communication
on DeviceNet bus
Description
Unable to established communication on DeviceNet bus < arg >
because no I/O units are physically connected.
Recommended actions
1. Check cables and connectors.
2. Connect I/O units to I/O bus.
3. Restart the system.
4. Remove I/O units on the I/O bus < arg > from the configuration.
71312, DeviceNet I/O unit explicit connection
not enabled
Description
DeviceNet I/O unit < arg > does not have the explicit message
connection enabled.
Recommended actions
Change configuration.
71313, Fieldbus command type order number
not unique.
Description
The I/O configuration is invalid.
Fieldbus command < arg > and < arg > are connected to the same unit
type < arg > and have the same order number < arg >.
The order number of commands connected to the same I/O unit must
be unique.
This command has been rejected.
Recommended actions
Correct the configuration.
71314, Invalid fieldbus command type
Description
The I/O configuration is invalid.
One of the fieldbus commands has a reference to an invalid/unknown
command type < arg >.
All fieldbus commands must refer to an existing command type.
This fieldbus command has been rejected.
Recommended actions
Correct the fieldbus command type for the command.
71315, Max number of fieldbus commands
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of fieldbus commands in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
fieldbus commands) so that the maximum limit is not exceeded.
71316, Max number of fieldbus command types
exceeded
Description
The I/O configuration is invalid.
The maximum number arg , of fieldbus command types in the I/O
system has been exceeded.
6 Trouble shooting by Event log
327
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
fieldbus command types) so that the maximum limit is not exceeded.
71317, DeviceNet I/O unit reset
Description
DeviceNet I/O unit < arg > have been restarted through fieldbus
command arg ,
to make sure fieldbus command values are activated.
This will cause the I/O unit to loose contact while the I/O unit is
restarted and then automatically be reconnected.
Recommended actions
1. Do nothing.
2. If restart not necessary remove fieldbus command configuration on
unit type.
71318, Failed to send fieldbus command
Description
Fieldbus command < arg > to I/O unit < arg > was not successfully sent.
Recommended actions
Check fieldbus command configuration.
71320, Max number of I/O access levels
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O access levels in the I/O system has
been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O access levels) so that the maximum limit is not exceeded.
71321, Invalid I/O access level
Description
The I/O configuration is invalid.
The I/O signal < arg > has a reference to an invalid/undefined I/O
access level < arg >.
All I/O signals must either omit the access level or refer to an existing
access level.
This I/O signal has been rejected.
Recommended actions
Change I/O access level to one that exist or define a new I/O access
level.
71323, Invalid bit values
Description
The I/O configuration for I/O signal < arg > is invalid.
The minimum bit value < arg > must not be less than < arg >.
The maximum bit value < arg > must not exceed < arg >.
The minimum bit value must be less than the maximum bit value.
This I/O signal has been rejected.
Recommended actions
1. Check that the I/O signal is configured with the correct encoding
type.
2. Check that the min and max bit values are correct.
71324, Physical limitation values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The physical limitation minimum value must be less than the physical
limitation maximum value.
This I/O signal has been rejected.
Recommended actions
Correct the physical limitation values for the I/O signal so that the
minimum value becomes less than the maximum value.
71325, Invalid I/O bus configuration
Description
The I/O configuration for I/O bus < arg > is invalid.
User-defined (externally loaded) I/O buses must no be specified as
local.
This I/O bus has been rejected.
Recommended actions
Change the bus type of the I/O bus.
71326, Invalid unit type configuration
Description
The I/O configuration for unit type < arg > is invalid.
User-defined (externally loaded) unit types must no be specified as
local.
This I/O bus has been rejected.
Recommended actions
Change the bus type of the I/O unit type.
71328, Invalid name
Description
The I/O configuration is invalid.
The configuration instance < arg > does not comply with the rules of
RAPID identifiers.
This configuration instance has been rejected.
Recommended actions
Correct the name of the configuration instance so that it complies with
the following rules:
Rules of RAPID identifiers:
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 329
|
6 Trouble shooting by Event log
326
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71308, DeviceNet generic connection 2
Description
On DeviceNet I/O unit < arg > connection 2 configuration are generic.
Real values:
- Connection 2 type: < arg >
- Connection 2 input size: < arg >
- Connection 2 output size: < arg >
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71309, DeviceNet generic unit identification
Description
On DeviceNet I/O unit < arg > identity configuration are generic.
Real values:
- Vendor Id: < arg >
- Product code: < arg >
- Device type: < arg >
Recommended actions
1. Create a new unit type with correct values.
2. Update your current unit type configuration.
71310, DeviceNet I/O unit connection error
Description
DeviceNet I/O unit < arg > is occupied by another master.
Recommended actions
1. Check configuration.
2. Cycle power on I/O unit.
71311, Unable to established communication
on DeviceNet bus
Description
Unable to established communication on DeviceNet bus < arg >
because no I/O units are physically connected.
Recommended actions
1. Check cables and connectors.
2. Connect I/O units to I/O bus.
3. Restart the system.
4. Remove I/O units on the I/O bus < arg > from the configuration.
71312, DeviceNet I/O unit explicit connection
not enabled
Description
DeviceNet I/O unit < arg > does not have the explicit message
connection enabled.
Recommended actions
Change configuration.
71313, Fieldbus command type order number
not unique.
Description
The I/O configuration is invalid.
Fieldbus command < arg > and < arg > are connected to the same unit
type < arg > and have the same order number < arg >.
The order number of commands connected to the same I/O unit must
be unique.
This command has been rejected.
Recommended actions
Correct the configuration.
71314, Invalid fieldbus command type
Description
The I/O configuration is invalid.
One of the fieldbus commands has a reference to an invalid/unknown
command type < arg >.
All fieldbus commands must refer to an existing command type.
This fieldbus command has been rejected.
Recommended actions
Correct the fieldbus command type for the command.
71315, Max number of fieldbus commands
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of fieldbus commands in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
fieldbus commands) so that the maximum limit is not exceeded.
71316, Max number of fieldbus command types
exceeded
Description
The I/O configuration is invalid.
The maximum number arg , of fieldbus command types in the I/O
system has been exceeded.
6 Trouble shooting by Event log
327
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
fieldbus command types) so that the maximum limit is not exceeded.
71317, DeviceNet I/O unit reset
Description
DeviceNet I/O unit < arg > have been restarted through fieldbus
command arg ,
to make sure fieldbus command values are activated.
This will cause the I/O unit to loose contact while the I/O unit is
restarted and then automatically be reconnected.
Recommended actions
1. Do nothing.
2. If restart not necessary remove fieldbus command configuration on
unit type.
71318, Failed to send fieldbus command
Description
Fieldbus command < arg > to I/O unit < arg > was not successfully sent.
Recommended actions
Check fieldbus command configuration.
71320, Max number of I/O access levels
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O access levels in the I/O system has
been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O access levels) so that the maximum limit is not exceeded.
71321, Invalid I/O access level
Description
The I/O configuration is invalid.
The I/O signal < arg > has a reference to an invalid/undefined I/O
access level < arg >.
All I/O signals must either omit the access level or refer to an existing
access level.
This I/O signal has been rejected.
Recommended actions
Change I/O access level to one that exist or define a new I/O access
level.
71323, Invalid bit values
Description
The I/O configuration for I/O signal < arg > is invalid.
The minimum bit value < arg > must not be less than < arg >.
The maximum bit value < arg > must not exceed < arg >.
The minimum bit value must be less than the maximum bit value.
This I/O signal has been rejected.
Recommended actions
1. Check that the I/O signal is configured with the correct encoding
type.
2. Check that the min and max bit values are correct.
71324, Physical limitation values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The physical limitation minimum value must be less than the physical
limitation maximum value.
This I/O signal has been rejected.
Recommended actions
Correct the physical limitation values for the I/O signal so that the
minimum value becomes less than the maximum value.
71325, Invalid I/O bus configuration
Description
The I/O configuration for I/O bus < arg > is invalid.
User-defined (externally loaded) I/O buses must no be specified as
local.
This I/O bus has been rejected.
Recommended actions
Change the bus type of the I/O bus.
71326, Invalid unit type configuration
Description
The I/O configuration for unit type < arg > is invalid.
User-defined (externally loaded) unit types must no be specified as
local.
This I/O bus has been rejected.
Recommended actions
Change the bus type of the I/O unit type.
71328, Invalid name
Description
The I/O configuration is invalid.
The configuration instance < arg > does not comply with the rules of
RAPID identifiers.
This configuration instance has been rejected.
Recommended actions
Correct the name of the configuration instance so that it complies with
the following rules:
Rules of RAPID identifiers:
6 Trouble shooting by Event log
328
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
1, The length must not exceed 16 characters.
2, The first character must be a letter (a-z or A-Z).
3, Subsequent characters must be letters (a-z or A-Z), digits (0-9) or
underscores (_).
71329, Invalid Connector ID
Description
The I/O configuration for I/O bus < arg > is invalid.
No or invalid connector ID is selected for the < arg > bus type.
This I/O bus has been rejected.
Recommended actions
Select a valid connector ID for the I/O bus.
71330, Conflicting bus types
Description
The I/O configuration for I/O bus < arg > is invalid.
There are duplicated < arg > I/O buses with same connector ID < arg >.
I/O buses of the same type must have unique connector ID:s.
This I/O bus has been rejected.
Recommended actions
Correct the connector ID for the I/O bus.
71331, Invalid bus type
Description
The I/O configuration for I/O bus < arg > is invalid.
The bus type < arg > is invalid or unknown
Installed valid bus types are: argargarg
Consequences
This I/O bus has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the bus type for the I/O bus.
71332, Invalid recovery time
Description
The I/O configuration for I/O bus < arg > is invalid.
The value of the recovery time parameter < arg > is incorrect.
The recovery time (how often to try regaining contact with lost I/O
units) must not be less than 5 seconds.
This I/O bus has been rejected.
Recommended actions
Correct the recovery time for the I/O bus.
71333, Invalid DeviceNet baud rate
Description
The I/O configuration for I/O bus < arg > is invalid.
The value of the DeviceNet baud rate parameter < arg > is incorrect.
Valid DeviceNet baud rates are:
- 125
- 250
- 500
This I/O bus has been rejected.
Recommended actions
Correct the DeviceNet baud rate for the I/O bus.
71334, Command type without reference to unit
type
Description
The I/O configuration is invalid.
No reference to a unit type is defined for the command type < arg >.
All command types must have a reference to an existing unit type.
This command type has been rejected.
Recommended actions
Define a unit type reference for the command type.
71335, Invalid unit type
Description
The I/O configuration for command type < arg > is invalid.
The unit type < arg > is invalid/unknown.
All command types must refer to an existing/defined unit type.
This command type has been rejected.
Recommended actions
Correct the unit type for the command type.
71336, Command type without DeviceNet path
Description
The I/O configuration is invalid.
No DeviceNet path is defined for the command type < arg >.
This command type has been rejected.
Recommended actions
Define a DeviceNet path < arg > for the command type.
71337, Command type without DeviceNet
service identifier
Description
The I/O configuration is invalid.
No DeviceNet service identifier is defined for the command type
< arg >.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 330
|
6 Trouble shooting by Event log
327
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
fieldbus command types) so that the maximum limit is not exceeded.
71317, DeviceNet I/O unit reset
Description
DeviceNet I/O unit < arg > have been restarted through fieldbus
command arg ,
to make sure fieldbus command values are activated.
This will cause the I/O unit to loose contact while the I/O unit is
restarted and then automatically be reconnected.
Recommended actions
1. Do nothing.
2. If restart not necessary remove fieldbus command configuration on
unit type.
71318, Failed to send fieldbus command
Description
Fieldbus command < arg > to I/O unit < arg > was not successfully sent.
Recommended actions
Check fieldbus command configuration.
71320, Max number of I/O access levels
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of I/O access levels in the I/O system has
been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O access levels) so that the maximum limit is not exceeded.
71321, Invalid I/O access level
Description
The I/O configuration is invalid.
The I/O signal < arg > has a reference to an invalid/undefined I/O
access level < arg >.
All I/O signals must either omit the access level or refer to an existing
access level.
This I/O signal has been rejected.
Recommended actions
Change I/O access level to one that exist or define a new I/O access
level.
71323, Invalid bit values
Description
The I/O configuration for I/O signal < arg > is invalid.
The minimum bit value < arg > must not be less than < arg >.
The maximum bit value < arg > must not exceed < arg >.
The minimum bit value must be less than the maximum bit value.
This I/O signal has been rejected.
Recommended actions
1. Check that the I/O signal is configured with the correct encoding
type.
2. Check that the min and max bit values are correct.
71324, Physical limitation values out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The physical limitation minimum value must be less than the physical
limitation maximum value.
This I/O signal has been rejected.
Recommended actions
Correct the physical limitation values for the I/O signal so that the
minimum value becomes less than the maximum value.
71325, Invalid I/O bus configuration
Description
The I/O configuration for I/O bus < arg > is invalid.
User-defined (externally loaded) I/O buses must no be specified as
local.
This I/O bus has been rejected.
Recommended actions
Change the bus type of the I/O bus.
71326, Invalid unit type configuration
Description
The I/O configuration for unit type < arg > is invalid.
User-defined (externally loaded) unit types must no be specified as
local.
This I/O bus has been rejected.
Recommended actions
Change the bus type of the I/O unit type.
71328, Invalid name
Description
The I/O configuration is invalid.
The configuration instance < arg > does not comply with the rules of
RAPID identifiers.
This configuration instance has been rejected.
Recommended actions
Correct the name of the configuration instance so that it complies with
the following rules:
Rules of RAPID identifiers:
6 Trouble shooting by Event log
328
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
1, The length must not exceed 16 characters.
2, The first character must be a letter (a-z or A-Z).
3, Subsequent characters must be letters (a-z or A-Z), digits (0-9) or
underscores (_).
71329, Invalid Connector ID
Description
The I/O configuration for I/O bus < arg > is invalid.
No or invalid connector ID is selected for the < arg > bus type.
This I/O bus has been rejected.
Recommended actions
Select a valid connector ID for the I/O bus.
71330, Conflicting bus types
Description
The I/O configuration for I/O bus < arg > is invalid.
There are duplicated < arg > I/O buses with same connector ID < arg >.
I/O buses of the same type must have unique connector ID:s.
This I/O bus has been rejected.
Recommended actions
Correct the connector ID for the I/O bus.
71331, Invalid bus type
Description
The I/O configuration for I/O bus < arg > is invalid.
The bus type < arg > is invalid or unknown
Installed valid bus types are: argargarg
Consequences
This I/O bus has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the bus type for the I/O bus.
71332, Invalid recovery time
Description
The I/O configuration for I/O bus < arg > is invalid.
The value of the recovery time parameter < arg > is incorrect.
The recovery time (how often to try regaining contact with lost I/O
units) must not be less than 5 seconds.
This I/O bus has been rejected.
Recommended actions
Correct the recovery time for the I/O bus.
71333, Invalid DeviceNet baud rate
Description
The I/O configuration for I/O bus < arg > is invalid.
The value of the DeviceNet baud rate parameter < arg > is incorrect.
Valid DeviceNet baud rates are:
- 125
- 250
- 500
This I/O bus has been rejected.
Recommended actions
Correct the DeviceNet baud rate for the I/O bus.
71334, Command type without reference to unit
type
Description
The I/O configuration is invalid.
No reference to a unit type is defined for the command type < arg >.
All command types must have a reference to an existing unit type.
This command type has been rejected.
Recommended actions
Define a unit type reference for the command type.
71335, Invalid unit type
Description
The I/O configuration for command type < arg > is invalid.
The unit type < arg > is invalid/unknown.
All command types must refer to an existing/defined unit type.
This command type has been rejected.
Recommended actions
Correct the unit type for the command type.
71336, Command type without DeviceNet path
Description
The I/O configuration is invalid.
No DeviceNet path is defined for the command type < arg >.
This command type has been rejected.
Recommended actions
Define a DeviceNet path < arg > for the command type.
71337, Command type without DeviceNet
service identifier
Description
The I/O configuration is invalid.
No DeviceNet service identifier is defined for the command type
< arg >.
6 Trouble shooting by Event log
329
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This command type has been rejected.
Recommended actions
Define a DeviceNet service identifier < arg > for the command type.
71338, Invalid DeviceNet service identifier
Description
The I/O configuration is invalid.
DeviceNet service identifier < arg > is not valid for command type
< arg >.
Valid DeviceNet service identifiers are:
< arg >
< arg >
< arg >
This command type has been rejected.
Recommended actions
Correct the DeviceNet service identifier for the command type.
71339, Fieldbus command without reference to
I/O unit
Description
The I/O configuration is invalid.
One of the fieldbus commands has no reference to a I/O unit.
All fieldbus commands must have a reference to an existing I/O unit.
This fieldbus command has been rejected.
Recommended actions
Define a I/O unit reference for the fieldbus command.
71340, Invalid I/O unit
Description
The I/O configuration is invalid.
One of the fieldbus commands has a reference to an invalid/unknown
I/O unit < arg >.
All fieldbus commands must have a reference to an existing I/O unit.
This fieldbus command has been rejected.
Recommended actions
Correct the I/O unit for the fieldbus command.
71341, Fieldbus command, no reference to
command type
Description
The I/O configuration is invalid.
One of the fieldbus commands has no reference to a command type.
All fieldbus commands must have a reference to an existing command
type.
This fieldbus command has been rejected.
Recommended actions
Define a command type reference for the fieldbus command.
71342, Unit type mismatch
Description
The I/O configuration is invalid.
One of the fieldbus commands refers to a I/O unit < arg > and a
command type < arg > that refer to different unit types.
The I/O unit and command type referred to by a fieldbus command
must refer to the same unit type.
This fieldbus command has been rejected.
Recommended actions
Correct the configuration.
71344, Unit map undefined
Description
The I/O configuration for I/O signal < arg > is invalid.
Unit map is undefined or empty.
A unit map must be specified for all physical I/O signals (i.e. signals
connected to an unit).
This I/O signal has been rejected.
Recommended actions
Define a unit map for the I/O signal.
71346, Unit map out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The unit map < arg > is invalid since bit < arg > is out of range.
All bits in the unit map must be in the range [0, arg ].
This I/O signal has been rejected.
Recommended actions
Correct the unit map.
71347, Unit map with overlapping segments
Description
The I/O configuration for I/O signal < arg > is invalid.
The unit map < arg > contains segments (e.g bit arg ) that overlap each
other.
This I/O signal has been rejected.
Recommended actions
Correct the unit map.
71348, Unit map with unexpected character
Description
The I/O configuration for I/O signal < arg > is invalid.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 331
|
6 Trouble shooting by Event log
328
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
1, The length must not exceed 16 characters.
2, The first character must be a letter (a-z or A-Z).
3, Subsequent characters must be letters (a-z or A-Z), digits (0-9) or
underscores (_).
71329, Invalid Connector ID
Description
The I/O configuration for I/O bus < arg > is invalid.
No or invalid connector ID is selected for the < arg > bus type.
This I/O bus has been rejected.
Recommended actions
Select a valid connector ID for the I/O bus.
71330, Conflicting bus types
Description
The I/O configuration for I/O bus < arg > is invalid.
There are duplicated < arg > I/O buses with same connector ID < arg >.
I/O buses of the same type must have unique connector ID:s.
This I/O bus has been rejected.
Recommended actions
Correct the connector ID for the I/O bus.
71331, Invalid bus type
Description
The I/O configuration for I/O bus < arg > is invalid.
The bus type < arg > is invalid or unknown
Installed valid bus types are: argargarg
Consequences
This I/O bus has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the bus type for the I/O bus.
71332, Invalid recovery time
Description
The I/O configuration for I/O bus < arg > is invalid.
The value of the recovery time parameter < arg > is incorrect.
The recovery time (how often to try regaining contact with lost I/O
units) must not be less than 5 seconds.
This I/O bus has been rejected.
Recommended actions
Correct the recovery time for the I/O bus.
71333, Invalid DeviceNet baud rate
Description
The I/O configuration for I/O bus < arg > is invalid.
The value of the DeviceNet baud rate parameter < arg > is incorrect.
Valid DeviceNet baud rates are:
- 125
- 250
- 500
This I/O bus has been rejected.
Recommended actions
Correct the DeviceNet baud rate for the I/O bus.
71334, Command type without reference to unit
type
Description
The I/O configuration is invalid.
No reference to a unit type is defined for the command type < arg >.
All command types must have a reference to an existing unit type.
This command type has been rejected.
Recommended actions
Define a unit type reference for the command type.
71335, Invalid unit type
Description
The I/O configuration for command type < arg > is invalid.
The unit type < arg > is invalid/unknown.
All command types must refer to an existing/defined unit type.
This command type has been rejected.
Recommended actions
Correct the unit type for the command type.
71336, Command type without DeviceNet path
Description
The I/O configuration is invalid.
No DeviceNet path is defined for the command type < arg >.
This command type has been rejected.
Recommended actions
Define a DeviceNet path < arg > for the command type.
71337, Command type without DeviceNet
service identifier
Description
The I/O configuration is invalid.
No DeviceNet service identifier is defined for the command type
< arg >.
6 Trouble shooting by Event log
329
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This command type has been rejected.
Recommended actions
Define a DeviceNet service identifier < arg > for the command type.
71338, Invalid DeviceNet service identifier
Description
The I/O configuration is invalid.
DeviceNet service identifier < arg > is not valid for command type
< arg >.
Valid DeviceNet service identifiers are:
< arg >
< arg >
< arg >
This command type has been rejected.
Recommended actions
Correct the DeviceNet service identifier for the command type.
71339, Fieldbus command without reference to
I/O unit
Description
The I/O configuration is invalid.
One of the fieldbus commands has no reference to a I/O unit.
All fieldbus commands must have a reference to an existing I/O unit.
This fieldbus command has been rejected.
Recommended actions
Define a I/O unit reference for the fieldbus command.
71340, Invalid I/O unit
Description
The I/O configuration is invalid.
One of the fieldbus commands has a reference to an invalid/unknown
I/O unit < arg >.
All fieldbus commands must have a reference to an existing I/O unit.
This fieldbus command has been rejected.
Recommended actions
Correct the I/O unit for the fieldbus command.
71341, Fieldbus command, no reference to
command type
Description
The I/O configuration is invalid.
One of the fieldbus commands has no reference to a command type.
All fieldbus commands must have a reference to an existing command
type.
This fieldbus command has been rejected.
Recommended actions
Define a command type reference for the fieldbus command.
71342, Unit type mismatch
Description
The I/O configuration is invalid.
One of the fieldbus commands refers to a I/O unit < arg > and a
command type < arg > that refer to different unit types.
The I/O unit and command type referred to by a fieldbus command
must refer to the same unit type.
This fieldbus command has been rejected.
Recommended actions
Correct the configuration.
71344, Unit map undefined
Description
The I/O configuration for I/O signal < arg > is invalid.
Unit map is undefined or empty.
A unit map must be specified for all physical I/O signals (i.e. signals
connected to an unit).
This I/O signal has been rejected.
Recommended actions
Define a unit map for the I/O signal.
71346, Unit map out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The unit map < arg > is invalid since bit < arg > is out of range.
All bits in the unit map must be in the range [0, arg ].
This I/O signal has been rejected.
Recommended actions
Correct the unit map.
71347, Unit map with overlapping segments
Description
The I/O configuration for I/O signal < arg > is invalid.
The unit map < arg > contains segments (e.g bit arg ) that overlap each
other.
This I/O signal has been rejected.
Recommended actions
Correct the unit map.
71348, Unit map with unexpected character
Description
The I/O configuration for I/O signal < arg > is invalid.
6 Trouble shooting by Event log
330
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Found unexpected end or character at position < arg > in the unit map:
< arg >.
This I/O signal has been rejected.
Recommended actions
Correct the unit map so that is comply with the following syntax:
- {bit} = ([0-9]+)
- {range} = ([0-9]+[-][0-9]+)
- {segment} = ({bit} | {range})
- {unit map} = ({segment}[,])*{segment}
Examples of valid unit maps:
- "1"
- "0-7, 15-8"
- "1,4-3,7"
71349, Invalid signal size
Description
The I/O configuration for I/O signal < arg > is invalid.
There is a mismatch between the signal type and the size of the signal.
The signal size < arg > is given by the unit map: < arg >.
This I/O signal has been rejected.
Recommended actions
Correct either the signal type or the unit map so that the following rules
are fulfilled:
- The size of digital I/O signals must be exactly one bit.
- The size of analog and group I/O signals must be between 2 and 32
bits.
71350, Invalid bus type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown bus type < arg >.
Installed valid bus types are: argargarg
Consequences
This unit type has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the bus type for the unit type.
71351, Invalid connection 1 type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown type for connection 1
< arg >.
The type for connection 1 must be one of the following:
- POLLED
- STROBE
- COS
- CYCLIC
- COS_ACKSUP
- CYCLIC_ACKSUP
This unit type has been rejected.
Recommended actions
Correct the connection 1 type of the unit type.
71352, Invalid connection 2 type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown type for connection 2
< arg >.
The type for connection 2 must either be omitted or one of the
following:
- POLLED
- STROBE
- COS
- CYCLIC
- COS_ACKSUP
- CYCLIC_ACKSUP
This unit type has been rejected.
Recommended actions
Correct the connection 2 type of the unit type.
71353, Unit without reference to unit type
Description
The I/O configuration is invalid.
No reference to a unit type is defined for the I/O unit < arg >.
This I/O signal has been rejected.
Recommended actions
Define a unit type reference for the I/O unit.
71354, I/O unit without reference to I/O bus
Description
The I/O configuration is invalid.
No reference to a I/O bus is defined for the I/O unit < arg >.
This I/O unit has been rejected.
Recommended actions
Define a I/O bus reference for the I/O unit.
71355, Invalid trustlevel
Description
The I/O configuration is invalid.
Unit type < arg > has an invalid/unknown trustlevel < arg >.
Valid trustlevel values are:
- 0 (Required)
- 1 (Error when lost)
- 2 (Loss accepted)
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 332
|
6 Trouble shooting by Event log
329
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This command type has been rejected.
Recommended actions
Define a DeviceNet service identifier < arg > for the command type.
71338, Invalid DeviceNet service identifier
Description
The I/O configuration is invalid.
DeviceNet service identifier < arg > is not valid for command type
< arg >.
Valid DeviceNet service identifiers are:
< arg >
< arg >
< arg >
This command type has been rejected.
Recommended actions
Correct the DeviceNet service identifier for the command type.
71339, Fieldbus command without reference to
I/O unit
Description
The I/O configuration is invalid.
One of the fieldbus commands has no reference to a I/O unit.
All fieldbus commands must have a reference to an existing I/O unit.
This fieldbus command has been rejected.
Recommended actions
Define a I/O unit reference for the fieldbus command.
71340, Invalid I/O unit
Description
The I/O configuration is invalid.
One of the fieldbus commands has a reference to an invalid/unknown
I/O unit < arg >.
All fieldbus commands must have a reference to an existing I/O unit.
This fieldbus command has been rejected.
Recommended actions
Correct the I/O unit for the fieldbus command.
71341, Fieldbus command, no reference to
command type
Description
The I/O configuration is invalid.
One of the fieldbus commands has no reference to a command type.
All fieldbus commands must have a reference to an existing command
type.
This fieldbus command has been rejected.
Recommended actions
Define a command type reference for the fieldbus command.
71342, Unit type mismatch
Description
The I/O configuration is invalid.
One of the fieldbus commands refers to a I/O unit < arg > and a
command type < arg > that refer to different unit types.
The I/O unit and command type referred to by a fieldbus command
must refer to the same unit type.
This fieldbus command has been rejected.
Recommended actions
Correct the configuration.
71344, Unit map undefined
Description
The I/O configuration for I/O signal < arg > is invalid.
Unit map is undefined or empty.
A unit map must be specified for all physical I/O signals (i.e. signals
connected to an unit).
This I/O signal has been rejected.
Recommended actions
Define a unit map for the I/O signal.
71346, Unit map out of range
Description
The I/O configuration for I/O signal < arg > is invalid.
The unit map < arg > is invalid since bit < arg > is out of range.
All bits in the unit map must be in the range [0, arg ].
This I/O signal has been rejected.
Recommended actions
Correct the unit map.
71347, Unit map with overlapping segments
Description
The I/O configuration for I/O signal < arg > is invalid.
The unit map < arg > contains segments (e.g bit arg ) that overlap each
other.
This I/O signal has been rejected.
Recommended actions
Correct the unit map.
71348, Unit map with unexpected character
Description
The I/O configuration for I/O signal < arg > is invalid.
6 Trouble shooting by Event log
330
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Found unexpected end or character at position < arg > in the unit map:
< arg >.
This I/O signal has been rejected.
Recommended actions
Correct the unit map so that is comply with the following syntax:
- {bit} = ([0-9]+)
- {range} = ([0-9]+[-][0-9]+)
- {segment} = ({bit} | {range})
- {unit map} = ({segment}[,])*{segment}
Examples of valid unit maps:
- "1"
- "0-7, 15-8"
- "1,4-3,7"
71349, Invalid signal size
Description
The I/O configuration for I/O signal < arg > is invalid.
There is a mismatch between the signal type and the size of the signal.
The signal size < arg > is given by the unit map: < arg >.
This I/O signal has been rejected.
Recommended actions
Correct either the signal type or the unit map so that the following rules
are fulfilled:
- The size of digital I/O signals must be exactly one bit.
- The size of analog and group I/O signals must be between 2 and 32
bits.
71350, Invalid bus type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown bus type < arg >.
Installed valid bus types are: argargarg
Consequences
This unit type has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the bus type for the unit type.
71351, Invalid connection 1 type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown type for connection 1
< arg >.
The type for connection 1 must be one of the following:
- POLLED
- STROBE
- COS
- CYCLIC
- COS_ACKSUP
- CYCLIC_ACKSUP
This unit type has been rejected.
Recommended actions
Correct the connection 1 type of the unit type.
71352, Invalid connection 2 type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown type for connection 2
< arg >.
The type for connection 2 must either be omitted or one of the
following:
- POLLED
- STROBE
- COS
- CYCLIC
- COS_ACKSUP
- CYCLIC_ACKSUP
This unit type has been rejected.
Recommended actions
Correct the connection 2 type of the unit type.
71353, Unit without reference to unit type
Description
The I/O configuration is invalid.
No reference to a unit type is defined for the I/O unit < arg >.
This I/O signal has been rejected.
Recommended actions
Define a unit type reference for the I/O unit.
71354, I/O unit without reference to I/O bus
Description
The I/O configuration is invalid.
No reference to a I/O bus is defined for the I/O unit < arg >.
This I/O unit has been rejected.
Recommended actions
Define a I/O bus reference for the I/O unit.
71355, Invalid trustlevel
Description
The I/O configuration is invalid.
Unit type < arg > has an invalid/unknown trustlevel < arg >.
Valid trustlevel values are:
- 0 (Required)
- 1 (Error when lost)
- 2 (Loss accepted)
6 Trouble shooting by Event log
331
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- 3 (Stop when lost)
This command type has been rejected.
Recommended actions
Correct the trustlevel for the unit type.
71356, Bus type mismatch
Description
The I/O configuration is invalid.
Unit < arg > refers to a I/O bus and a unit type with different bus types.
This I/O unit has been rejected.
Recommended actions
1. Check that the I/O unit is connected to the correct I/O bus and that
the bus type of that I/O bus is correct.
2. Check that the I/O unit refers to the correct unit type and that the bus
type of that unit type is correct.
71357, Duplicated I/O units on I/O bus <Local>
Description
The I/O configuration for I/O unit < arg > is invalid.
There is already another user-defined I/O unit connected to the I/O bus
<Local>.
Only one user-defined I/O unit may be connected to the I/O bus
<Local>.
This I/O unit has been rejected.
Recommended actions
Correct the I/O configuration.
71358, Power fail restore full
Description
I/O unit < arg > could not be setup for power failure restore.
The table for power fail is full.
Recommended actions
Remove some other I/O units from the restore list.
71359, Option Multiple Serial Ports is not
installed
Description
The system has attempted to address the serial port < arg >, and failed.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
The option, Multiple Serial Ports, has not been installed in the system.
Recommended actions
1. If the option is required: configure a new system WITH this option,
and install the system.
2. If the option is NOT required: remove the unsupported
communication channels from the configuration.
71361, Cross connection with non digital
resultant signal
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
refer to a I/O signal < arg >, that is not digital.
Only digital I/O signals can be cross connected.
This cross connection has been rejected.
Recommended actions
Remove the non-digital I/O signal from the cross connection.
71362, I/O signal mapped outside the I/O unit
data area
Description
Cannot change physical state of I/O signal < arg > to VALID.
The reason is that the I/O signal is mapped to bit(s) that lies outside the
data area of the I/O unit it is assigned to.
I/O signal assigned to I/O unit < arg >
I/O signal mapped to bit(s): < arg >
Output data area size for the I/O unit is arg bits
Input data area size for the I/O unit is arg bits
Consequences
The physical state of this I/O signal remains NOT VALID.
Recommended actions
1. Check that the unit mapping of the I/O signal is correct.
2. Check that the I/O signal is assigned to the correct I/O unit.
3. Check the system parameters Connection Input/Output size on the
unit type, it is possible to increase those parameters on some unit types.
71363, Slave configuration invalid
Description
The I/O unit < arg > configured on the master address is not valid as an
internal slave.
Recommended actions
1. Change the address on the I/O unit.
2. Change the unit type on the unit to DN_SLAVE.
71364, I/O queue overload
Description
The I/O queue handling input and output I/O signals to and from the
system has been overloaded.
Consequences
The system will go to status SYS STOP.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 333
|
6 Trouble shooting by Event log
330
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Found unexpected end or character at position < arg > in the unit map:
< arg >.
This I/O signal has been rejected.
Recommended actions
Correct the unit map so that is comply with the following syntax:
- {bit} = ([0-9]+)
- {range} = ([0-9]+[-][0-9]+)
- {segment} = ({bit} | {range})
- {unit map} = ({segment}[,])*{segment}
Examples of valid unit maps:
- "1"
- "0-7, 15-8"
- "1,4-3,7"
71349, Invalid signal size
Description
The I/O configuration for I/O signal < arg > is invalid.
There is a mismatch between the signal type and the size of the signal.
The signal size < arg > is given by the unit map: < arg >.
This I/O signal has been rejected.
Recommended actions
Correct either the signal type or the unit map so that the following rules
are fulfilled:
- The size of digital I/O signals must be exactly one bit.
- The size of analog and group I/O signals must be between 2 and 32
bits.
71350, Invalid bus type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown bus type < arg >.
Installed valid bus types are: argargarg
Consequences
This unit type has been rejected, and no functions depending on it will
work.
Recommended actions
Correct the bus type for the unit type.
71351, Invalid connection 1 type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown type for connection 1
< arg >.
The type for connection 1 must be one of the following:
- POLLED
- STROBE
- COS
- CYCLIC
- COS_ACKSUP
- CYCLIC_ACKSUP
This unit type has been rejected.
Recommended actions
Correct the connection 1 type of the unit type.
71352, Invalid connection 2 type
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown type for connection 2
< arg >.
The type for connection 2 must either be omitted or one of the
following:
- POLLED
- STROBE
- COS
- CYCLIC
- COS_ACKSUP
- CYCLIC_ACKSUP
This unit type has been rejected.
Recommended actions
Correct the connection 2 type of the unit type.
71353, Unit without reference to unit type
Description
The I/O configuration is invalid.
No reference to a unit type is defined for the I/O unit < arg >.
This I/O signal has been rejected.
Recommended actions
Define a unit type reference for the I/O unit.
71354, I/O unit without reference to I/O bus
Description
The I/O configuration is invalid.
No reference to a I/O bus is defined for the I/O unit < arg >.
This I/O unit has been rejected.
Recommended actions
Define a I/O bus reference for the I/O unit.
71355, Invalid trustlevel
Description
The I/O configuration is invalid.
Unit type < arg > has an invalid/unknown trustlevel < arg >.
Valid trustlevel values are:
- 0 (Required)
- 1 (Error when lost)
- 2 (Loss accepted)
6 Trouble shooting by Event log
331
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- 3 (Stop when lost)
This command type has been rejected.
Recommended actions
Correct the trustlevel for the unit type.
71356, Bus type mismatch
Description
The I/O configuration is invalid.
Unit < arg > refers to a I/O bus and a unit type with different bus types.
This I/O unit has been rejected.
Recommended actions
1. Check that the I/O unit is connected to the correct I/O bus and that
the bus type of that I/O bus is correct.
2. Check that the I/O unit refers to the correct unit type and that the bus
type of that unit type is correct.
71357, Duplicated I/O units on I/O bus <Local>
Description
The I/O configuration for I/O unit < arg > is invalid.
There is already another user-defined I/O unit connected to the I/O bus
<Local>.
Only one user-defined I/O unit may be connected to the I/O bus
<Local>.
This I/O unit has been rejected.
Recommended actions
Correct the I/O configuration.
71358, Power fail restore full
Description
I/O unit < arg > could not be setup for power failure restore.
The table for power fail is full.
Recommended actions
Remove some other I/O units from the restore list.
71359, Option Multiple Serial Ports is not
installed
Description
The system has attempted to address the serial port < arg >, and failed.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
The option, Multiple Serial Ports, has not been installed in the system.
Recommended actions
1. If the option is required: configure a new system WITH this option,
and install the system.
2. If the option is NOT required: remove the unsupported
communication channels from the configuration.
71361, Cross connection with non digital
resultant signal
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
refer to a I/O signal < arg >, that is not digital.
Only digital I/O signals can be cross connected.
This cross connection has been rejected.
Recommended actions
Remove the non-digital I/O signal from the cross connection.
71362, I/O signal mapped outside the I/O unit
data area
Description
Cannot change physical state of I/O signal < arg > to VALID.
The reason is that the I/O signal is mapped to bit(s) that lies outside the
data area of the I/O unit it is assigned to.
I/O signal assigned to I/O unit < arg >
I/O signal mapped to bit(s): < arg >
Output data area size for the I/O unit is arg bits
Input data area size for the I/O unit is arg bits
Consequences
The physical state of this I/O signal remains NOT VALID.
Recommended actions
1. Check that the unit mapping of the I/O signal is correct.
2. Check that the I/O signal is assigned to the correct I/O unit.
3. Check the system parameters Connection Input/Output size on the
unit type, it is possible to increase those parameters on some unit types.
71363, Slave configuration invalid
Description
The I/O unit < arg > configured on the master address is not valid as an
internal slave.
Recommended actions
1. Change the address on the I/O unit.
2. Change the unit type on the unit to DN_SLAVE.
71364, I/O queue overload
Description
The I/O queue handling input and output I/O signals to and from the
system has been overloaded.
Consequences
The system will go to status SYS STOP.
6 Trouble shooting by Event log
332
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
This is caused by too frequent signal changes or too large bursts of
signal changes, generated by input I/O signals or cross connections
between I/O signals.
Recommended actions
Check the cross connections. How to check the configuration file is
detailed in the Trouble Shooting Manual.
2. Check the frequency of input I/O signals from any external
equipment connected to the system. Make sure it is not abnormal, and
change if required.
3. If an extremely heavy I/O load is normal and required, investigate
whether programming delays in the RAPID application may solve the
problem.
71365, Safety I/O queue overload
Description
The safety I/O queue handling safety input and output I/O signals has
been overloaded.
Consequences
The system will go to status SYS HALT.
Probable causes
This is caused by too frequent signal changes of safety I/O signals.
Sometimes this may be due to erratic ground connection in I/O signals
from external equipment.
Recommended actions
1. Repeated safety input I/O signals will cause the system to halt.
See the error log for other faults that may cause the condition.
2. Check the grounding of each signal from any external equipment
affecting the safety I/O signals.
3. Check the frequency of input I/O signals from any external
equipment connected to the system. Make sure it is not abnormal, and
change is required.
71366, Cross connection I/O queue overload
Description
The cross connection I/O queue handling input and output I/O signals
to and from the system has been overloaded.
Consequences
The system will go to status SYS STOP.
Probable causes
This is caused by too frequent signal changes or too large bursts of
signal changes, generated by input or output I/O signals being actors
in cross connections.
Recommended actions
Check the cross connections. How to check the configuration file is
detailed in the Trouble Shooting Manual.
2. Check the frequency of input and output I/O signals being actors in
cross connections.
3. If an extremely heavy I/O load is normal and required, investigate
whether programming delays in the RAPID application may solve the
problem.
71367, No communication with I/O unit
Description
During start-up, no communication was established with I/O unit
< arg > on the I/O bus < arg >.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller. The system will go to
state SYS FAIL, if the I/O unit has been assigned Unit Trustlevel
<Required (0)> in the configuration.
Probable causes
The I/O unit is either not connected to the system, or it is connected,
but has been assigned the wrong address.
Recommended actions
1. Make sure all I/O unit addresses match the configuration.
2. Make sure all addresses are unique, and not used by more than one
I/O unit.
3. Change the address and/or connect the missing I/O unit.
4. If you changed the address, the power supply to the I/O unit must be
cycled (switched OFF and then back ON), to make sure the address has
been changed.
71368, No Interbus option has been installed
Description
A Interbus master/slave board has been fitted, but no Interbus option
has been installed.
Consequences
No communication on the Interbus is possible. There may be
consequential errors from configuring Interbus when no such option
has been installed.
Probable causes
An attempt may have been made to add the Interbus functionality,
without installing the option correctly.
Recommended actions
1. If the Interbus option is required: configure a new system WITH this
option, and install the system.
2. If the Interbus option is NOT required: configure a new system
WITHOUT this option, and install the system.
71377, Dengensha board failure
Description
No contact with Dengensha PCI board.
Consequences
Dengensha Spot Welding will not be available for use.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 334
|
6 Trouble shooting by Event log
331
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
- 3 (Stop when lost)
This command type has been rejected.
Recommended actions
Correct the trustlevel for the unit type.
71356, Bus type mismatch
Description
The I/O configuration is invalid.
Unit < arg > refers to a I/O bus and a unit type with different bus types.
This I/O unit has been rejected.
Recommended actions
1. Check that the I/O unit is connected to the correct I/O bus and that
the bus type of that I/O bus is correct.
2. Check that the I/O unit refers to the correct unit type and that the bus
type of that unit type is correct.
71357, Duplicated I/O units on I/O bus <Local>
Description
The I/O configuration for I/O unit < arg > is invalid.
There is already another user-defined I/O unit connected to the I/O bus
<Local>.
Only one user-defined I/O unit may be connected to the I/O bus
<Local>.
This I/O unit has been rejected.
Recommended actions
Correct the I/O configuration.
71358, Power fail restore full
Description
I/O unit < arg > could not be setup for power failure restore.
The table for power fail is full.
Recommended actions
Remove some other I/O units from the restore list.
71359, Option Multiple Serial Ports is not
installed
Description
The system has attempted to address the serial port < arg >, and failed.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
The option, Multiple Serial Ports, has not been installed in the system.
Recommended actions
1. If the option is required: configure a new system WITH this option,
and install the system.
2. If the option is NOT required: remove the unsupported
communication channels from the configuration.
71361, Cross connection with non digital
resultant signal
Description
The I/O configuration is invalid.
The parameter <Resultant I/O signal> of one of the cross connections
refer to a I/O signal < arg >, that is not digital.
Only digital I/O signals can be cross connected.
This cross connection has been rejected.
Recommended actions
Remove the non-digital I/O signal from the cross connection.
71362, I/O signal mapped outside the I/O unit
data area
Description
Cannot change physical state of I/O signal < arg > to VALID.
The reason is that the I/O signal is mapped to bit(s) that lies outside the
data area of the I/O unit it is assigned to.
I/O signal assigned to I/O unit < arg >
I/O signal mapped to bit(s): < arg >
Output data area size for the I/O unit is arg bits
Input data area size for the I/O unit is arg bits
Consequences
The physical state of this I/O signal remains NOT VALID.
Recommended actions
1. Check that the unit mapping of the I/O signal is correct.
2. Check that the I/O signal is assigned to the correct I/O unit.
3. Check the system parameters Connection Input/Output size on the
unit type, it is possible to increase those parameters on some unit types.
71363, Slave configuration invalid
Description
The I/O unit < arg > configured on the master address is not valid as an
internal slave.
Recommended actions
1. Change the address on the I/O unit.
2. Change the unit type on the unit to DN_SLAVE.
71364, I/O queue overload
Description
The I/O queue handling input and output I/O signals to and from the
system has been overloaded.
Consequences
The system will go to status SYS STOP.
6 Trouble shooting by Event log
332
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
This is caused by too frequent signal changes or too large bursts of
signal changes, generated by input I/O signals or cross connections
between I/O signals.
Recommended actions
Check the cross connections. How to check the configuration file is
detailed in the Trouble Shooting Manual.
2. Check the frequency of input I/O signals from any external
equipment connected to the system. Make sure it is not abnormal, and
change if required.
3. If an extremely heavy I/O load is normal and required, investigate
whether programming delays in the RAPID application may solve the
problem.
71365, Safety I/O queue overload
Description
The safety I/O queue handling safety input and output I/O signals has
been overloaded.
Consequences
The system will go to status SYS HALT.
Probable causes
This is caused by too frequent signal changes of safety I/O signals.
Sometimes this may be due to erratic ground connection in I/O signals
from external equipment.
Recommended actions
1. Repeated safety input I/O signals will cause the system to halt.
See the error log for other faults that may cause the condition.
2. Check the grounding of each signal from any external equipment
affecting the safety I/O signals.
3. Check the frequency of input I/O signals from any external
equipment connected to the system. Make sure it is not abnormal, and
change is required.
71366, Cross connection I/O queue overload
Description
The cross connection I/O queue handling input and output I/O signals
to and from the system has been overloaded.
Consequences
The system will go to status SYS STOP.
Probable causes
This is caused by too frequent signal changes or too large bursts of
signal changes, generated by input or output I/O signals being actors
in cross connections.
Recommended actions
Check the cross connections. How to check the configuration file is
detailed in the Trouble Shooting Manual.
2. Check the frequency of input and output I/O signals being actors in
cross connections.
3. If an extremely heavy I/O load is normal and required, investigate
whether programming delays in the RAPID application may solve the
problem.
71367, No communication with I/O unit
Description
During start-up, no communication was established with I/O unit
< arg > on the I/O bus < arg >.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller. The system will go to
state SYS FAIL, if the I/O unit has been assigned Unit Trustlevel
<Required (0)> in the configuration.
Probable causes
The I/O unit is either not connected to the system, or it is connected,
but has been assigned the wrong address.
Recommended actions
1. Make sure all I/O unit addresses match the configuration.
2. Make sure all addresses are unique, and not used by more than one
I/O unit.
3. Change the address and/or connect the missing I/O unit.
4. If you changed the address, the power supply to the I/O unit must be
cycled (switched OFF and then back ON), to make sure the address has
been changed.
71368, No Interbus option has been installed
Description
A Interbus master/slave board has been fitted, but no Interbus option
has been installed.
Consequences
No communication on the Interbus is possible. There may be
consequential errors from configuring Interbus when no such option
has been installed.
Probable causes
An attempt may have been made to add the Interbus functionality,
without installing the option correctly.
Recommended actions
1. If the Interbus option is required: configure a new system WITH this
option, and install the system.
2. If the Interbus option is NOT required: configure a new system
WITHOUT this option, and install the system.
71377, Dengensha board failure
Description
No contact with Dengensha PCI board.
Consequences
Dengensha Spot Welding will not be available for use.
6 Trouble shooting by Event log
333
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
-Dengensha board not present in PCI contact.
Recommended actions
1. Install the PCI card into one of the main computers PCI slots.
2. Make sure the PCI card is working.
71378, Failed to access the Dengensha PCI
board.
Description
The Dengensha PCI board has stopped responding.
Consequences
Dengensha Spot Welding will not be available for use.
Probable causes
-The board may have internal software or hardware problems.
Recommended actions
Power off and try again
71379, Unknown communication physical
channel connector
Description
The connector < arg > defined for the physical channel < arg > is
unknown.
Consequences
The physical channel will not be available for use.
Probable causes
-The connector defined in the physical channel configuration may be
misspelt or refers to a connector not available for use.
- Connector configuration is missing.
Recommended actions
1. Make sure the connector defined in the physical channel
configuration is referring to an available connector.
2. Make sure the option Multiple Serial Ports is installed if required by
the used configuration.
3. Reinstall the system to make sure the system configuration files are
OK.
71380, Communication connector driver is
already in use
Description
The connector < arg > cannot use the driver < arg >. The driver is already
in use by connector < arg >.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
-The configuration files may have been faulty.
-A configuration file with improperly configured Physical Channels
may have been loaded.
Recommended actions
1. Make sure physical connector configuration is valid.
2. Reinstall the system to make sure the system configuration files are
OK.
71381, Communication connector is already in
use
Description
The physical channel < arg > cannot use connector < arg >. The
connector is already in use by physical channel < arg >.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
Several physical channels may have been assigned to the same
connector in the configuration.
Recommended actions
Make sure each connector is used by one physical channel only.
71382, DeviceNet watchdog time has expired
Description
The system has not received any reply from the DeviceNet unit, and
the watchdog timer has timed out.
Consequences
The DeviceNet bus is NOT running, and no communication on the
DeviceNet bus < arg > will be possible. The system goes to status SYS
FAIL. The full meaning of this status is described in the Trouble
Shooting Manual, IRC5.
Probable causes
The I/O load on the DeviceNet bus may be too high, for instance if a
RAPID program is trying to set I/O signals at a rate that exceeds the
bandwidth available on the DeviceNet bus.
Recommended actions
Reduce the I/O load on the DeviceNet bus.
71383, User defined I/O units can't be
connected to the I/O bus <Local>
Description
The I/O configuration for I/O unit < arg > is invalid.
No user-defined unit may be connected to the I/O bus <Local>.
This I/O unit has been rejected.
Recommended actions
Correct the I/O configuration.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 335
|
6 Trouble shooting by Event log
332
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
This is caused by too frequent signal changes or too large bursts of
signal changes, generated by input I/O signals or cross connections
between I/O signals.
Recommended actions
Check the cross connections. How to check the configuration file is
detailed in the Trouble Shooting Manual.
2. Check the frequency of input I/O signals from any external
equipment connected to the system. Make sure it is not abnormal, and
change if required.
3. If an extremely heavy I/O load is normal and required, investigate
whether programming delays in the RAPID application may solve the
problem.
71365, Safety I/O queue overload
Description
The safety I/O queue handling safety input and output I/O signals has
been overloaded.
Consequences
The system will go to status SYS HALT.
Probable causes
This is caused by too frequent signal changes of safety I/O signals.
Sometimes this may be due to erratic ground connection in I/O signals
from external equipment.
Recommended actions
1. Repeated safety input I/O signals will cause the system to halt.
See the error log for other faults that may cause the condition.
2. Check the grounding of each signal from any external equipment
affecting the safety I/O signals.
3. Check the frequency of input I/O signals from any external
equipment connected to the system. Make sure it is not abnormal, and
change is required.
71366, Cross connection I/O queue overload
Description
The cross connection I/O queue handling input and output I/O signals
to and from the system has been overloaded.
Consequences
The system will go to status SYS STOP.
Probable causes
This is caused by too frequent signal changes or too large bursts of
signal changes, generated by input or output I/O signals being actors
in cross connections.
Recommended actions
Check the cross connections. How to check the configuration file is
detailed in the Trouble Shooting Manual.
2. Check the frequency of input and output I/O signals being actors in
cross connections.
3. If an extremely heavy I/O load is normal and required, investigate
whether programming delays in the RAPID application may solve the
problem.
71367, No communication with I/O unit
Description
During start-up, no communication was established with I/O unit
< arg > on the I/O bus < arg >.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller. The system will go to
state SYS FAIL, if the I/O unit has been assigned Unit Trustlevel
<Required (0)> in the configuration.
Probable causes
The I/O unit is either not connected to the system, or it is connected,
but has been assigned the wrong address.
Recommended actions
1. Make sure all I/O unit addresses match the configuration.
2. Make sure all addresses are unique, and not used by more than one
I/O unit.
3. Change the address and/or connect the missing I/O unit.
4. If you changed the address, the power supply to the I/O unit must be
cycled (switched OFF and then back ON), to make sure the address has
been changed.
71368, No Interbus option has been installed
Description
A Interbus master/slave board has been fitted, but no Interbus option
has been installed.
Consequences
No communication on the Interbus is possible. There may be
consequential errors from configuring Interbus when no such option
has been installed.
Probable causes
An attempt may have been made to add the Interbus functionality,
without installing the option correctly.
Recommended actions
1. If the Interbus option is required: configure a new system WITH this
option, and install the system.
2. If the Interbus option is NOT required: configure a new system
WITHOUT this option, and install the system.
71377, Dengensha board failure
Description
No contact with Dengensha PCI board.
Consequences
Dengensha Spot Welding will not be available for use.
6 Trouble shooting by Event log
333
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
-Dengensha board not present in PCI contact.
Recommended actions
1. Install the PCI card into one of the main computers PCI slots.
2. Make sure the PCI card is working.
71378, Failed to access the Dengensha PCI
board.
Description
The Dengensha PCI board has stopped responding.
Consequences
Dengensha Spot Welding will not be available for use.
Probable causes
-The board may have internal software or hardware problems.
Recommended actions
Power off and try again
71379, Unknown communication physical
channel connector
Description
The connector < arg > defined for the physical channel < arg > is
unknown.
Consequences
The physical channel will not be available for use.
Probable causes
-The connector defined in the physical channel configuration may be
misspelt or refers to a connector not available for use.
- Connector configuration is missing.
Recommended actions
1. Make sure the connector defined in the physical channel
configuration is referring to an available connector.
2. Make sure the option Multiple Serial Ports is installed if required by
the used configuration.
3. Reinstall the system to make sure the system configuration files are
OK.
71380, Communication connector driver is
already in use
Description
The connector < arg > cannot use the driver < arg >. The driver is already
in use by connector < arg >.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
-The configuration files may have been faulty.
-A configuration file with improperly configured Physical Channels
may have been loaded.
Recommended actions
1. Make sure physical connector configuration is valid.
2. Reinstall the system to make sure the system configuration files are
OK.
71381, Communication connector is already in
use
Description
The physical channel < arg > cannot use connector < arg >. The
connector is already in use by physical channel < arg >.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
Several physical channels may have been assigned to the same
connector in the configuration.
Recommended actions
Make sure each connector is used by one physical channel only.
71382, DeviceNet watchdog time has expired
Description
The system has not received any reply from the DeviceNet unit, and
the watchdog timer has timed out.
Consequences
The DeviceNet bus is NOT running, and no communication on the
DeviceNet bus < arg > will be possible. The system goes to status SYS
FAIL. The full meaning of this status is described in the Trouble
Shooting Manual, IRC5.
Probable causes
The I/O load on the DeviceNet bus may be too high, for instance if a
RAPID program is trying to set I/O signals at a rate that exceeds the
bandwidth available on the DeviceNet bus.
Recommended actions
Reduce the I/O load on the DeviceNet bus.
71383, User defined I/O units can't be
connected to the I/O bus <Local>
Description
The I/O configuration for I/O unit < arg > is invalid.
No user-defined unit may be connected to the I/O bus <Local>.
This I/O unit has been rejected.
Recommended actions
Correct the I/O configuration.
6 Trouble shooting by Event log
334
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71385, Request message resource exhausted
Description
Unable to handle more concurrent IO requests.
Out of concurrent I/O request using delay, pulse, or timeout argument.
Consequences
I/O request cannot be fulfilled.
Probable causes
To many I/O instructions with pulse or delay argument.
To many process instructions with pulse, delay or timeout.
Recommended actions
1. Reduce the number of concurrent I/O instructions with pulse or
delay argument.
2. Reduce the number of concurrent process instructions that use pulse,
delay or timeout argument.
71386, DeviceNet Quick Connect not supported
Description
The unit type < arg > may not be connected to the DeviceNet bus as a
Quick Connect I/O unit.
Consequences
This unit type has been rejected, and no functions depending on this
unit type will work.
Probable causes
The unit connected may be of a too early version.
Recommended actions
1. Disable the Quick Connect configuration parameter.
2. Replace the DeviceNet master/slave board with a later version.
71389, Configuration file error
Description
Errors occurred during loading of configuration data.
All configuration errors are placed in the cfg Event Log.
Consequences
The configuration in file will not be installed.
Recommended actions
View the errors in the cfg Event log.
71390, The DeviceNet bus have recovered from
bus off
Description
The DeviceNet bus < arg > have recovered from bus off state.
71391, System Signal configuration
Description
There was an error during the configuration of a System Input/Output
Signal.
System I/O name: arg
Consequences
The system will go to state SYS FAIL.
Probable causes
All errors during configuration of System Input/Output Signals are
considered fatal and the system will go to state SYS FAIL.
Recommended actions
1. Check the connection of the Unit to which the System Signal is
connected.
2. Check the configuration of the I/O unit.
71392, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 1 output size < arg > does
not match the I/O unit. When using strobe connection the only valid
output size are 1 or -1.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type.
71393, Error when allocating generic size
Description
Failed to allocate generic arg size (-1) on DeviceNet I/O unit < arg >.
Probable causes
The DeviceNet I/O unit < arg > cannot be configured with unit type
DN_GENERIC or with a generic arg size (-1).
Recommended actions
1. Update your current unit type configuration with new arg size.
2. Do not use DN_GENERIC unit type.
71394, Invalid physical communication channel
Description
The communication channel arg is out of range.
Consequences
The communication channel arg is unavailable.
Probable causes
Option not installed or the communication channel < arg > is out of
range.
Recommended actions
1. Check the allowed minimum and maximum of connectors.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 336
|
6 Trouble shooting by Event log
333
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
-Dengensha board not present in PCI contact.
Recommended actions
1. Install the PCI card into one of the main computers PCI slots.
2. Make sure the PCI card is working.
71378, Failed to access the Dengensha PCI
board.
Description
The Dengensha PCI board has stopped responding.
Consequences
Dengensha Spot Welding will not be available for use.
Probable causes
-The board may have internal software or hardware problems.
Recommended actions
Power off and try again
71379, Unknown communication physical
channel connector
Description
The connector < arg > defined for the physical channel < arg > is
unknown.
Consequences
The physical channel will not be available for use.
Probable causes
-The connector defined in the physical channel configuration may be
misspelt or refers to a connector not available for use.
- Connector configuration is missing.
Recommended actions
1. Make sure the connector defined in the physical channel
configuration is referring to an available connector.
2. Make sure the option Multiple Serial Ports is installed if required by
the used configuration.
3. Reinstall the system to make sure the system configuration files are
OK.
71380, Communication connector driver is
already in use
Description
The connector < arg > cannot use the driver < arg >. The driver is already
in use by connector < arg >.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
-The configuration files may have been faulty.
-A configuration file with improperly configured Physical Channels
may have been loaded.
Recommended actions
1. Make sure physical connector configuration is valid.
2. Reinstall the system to make sure the system configuration files are
OK.
71381, Communication connector is already in
use
Description
The physical channel < arg > cannot use connector < arg >. The
connector is already in use by physical channel < arg >.
Consequences
The connector and the physical channel using the connector will not be
available for use.
Probable causes
Several physical channels may have been assigned to the same
connector in the configuration.
Recommended actions
Make sure each connector is used by one physical channel only.
71382, DeviceNet watchdog time has expired
Description
The system has not received any reply from the DeviceNet unit, and
the watchdog timer has timed out.
Consequences
The DeviceNet bus is NOT running, and no communication on the
DeviceNet bus < arg > will be possible. The system goes to status SYS
FAIL. The full meaning of this status is described in the Trouble
Shooting Manual, IRC5.
Probable causes
The I/O load on the DeviceNet bus may be too high, for instance if a
RAPID program is trying to set I/O signals at a rate that exceeds the
bandwidth available on the DeviceNet bus.
Recommended actions
Reduce the I/O load on the DeviceNet bus.
71383, User defined I/O units can't be
connected to the I/O bus <Local>
Description
The I/O configuration for I/O unit < arg > is invalid.
No user-defined unit may be connected to the I/O bus <Local>.
This I/O unit has been rejected.
Recommended actions
Correct the I/O configuration.
6 Trouble shooting by Event log
334
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71385, Request message resource exhausted
Description
Unable to handle more concurrent IO requests.
Out of concurrent I/O request using delay, pulse, or timeout argument.
Consequences
I/O request cannot be fulfilled.
Probable causes
To many I/O instructions with pulse or delay argument.
To many process instructions with pulse, delay or timeout.
Recommended actions
1. Reduce the number of concurrent I/O instructions with pulse or
delay argument.
2. Reduce the number of concurrent process instructions that use pulse,
delay or timeout argument.
71386, DeviceNet Quick Connect not supported
Description
The unit type < arg > may not be connected to the DeviceNet bus as a
Quick Connect I/O unit.
Consequences
This unit type has been rejected, and no functions depending on this
unit type will work.
Probable causes
The unit connected may be of a too early version.
Recommended actions
1. Disable the Quick Connect configuration parameter.
2. Replace the DeviceNet master/slave board with a later version.
71389, Configuration file error
Description
Errors occurred during loading of configuration data.
All configuration errors are placed in the cfg Event Log.
Consequences
The configuration in file will not be installed.
Recommended actions
View the errors in the cfg Event log.
71390, The DeviceNet bus have recovered from
bus off
Description
The DeviceNet bus < arg > have recovered from bus off state.
71391, System Signal configuration
Description
There was an error during the configuration of a System Input/Output
Signal.
System I/O name: arg
Consequences
The system will go to state SYS FAIL.
Probable causes
All errors during configuration of System Input/Output Signals are
considered fatal and the system will go to state SYS FAIL.
Recommended actions
1. Check the connection of the Unit to which the System Signal is
connected.
2. Check the configuration of the I/O unit.
71392, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 1 output size < arg > does
not match the I/O unit. When using strobe connection the only valid
output size are 1 or -1.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type.
71393, Error when allocating generic size
Description
Failed to allocate generic arg size (-1) on DeviceNet I/O unit < arg >.
Probable causes
The DeviceNet I/O unit < arg > cannot be configured with unit type
DN_GENERIC or with a generic arg size (-1).
Recommended actions
1. Update your current unit type configuration with new arg size.
2. Do not use DN_GENERIC unit type.
71394, Invalid physical communication channel
Description
The communication channel arg is out of range.
Consequences
The communication channel arg is unavailable.
Probable causes
Option not installed or the communication channel < arg > is out of
range.
Recommended actions
1. Check the allowed minimum and maximum of connectors.
6 Trouble shooting by Event log
335
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
2. Check options required.
71395, No transport protocol
Description
The transport protocol < arg > for channel < arg > is missing.
Consequences
The transport instance < arg > is unavailable.
Probable causes
The option holding the transport protocol < arg > is not installed or the
protocol name is faulty.
Recommended actions
1. Install missing option.
2. Change the transport protocol name.
71396, No transmission protocol
Description
The transport protocol < arg > is missing or the name of the transport
protocol is faulty for < arg >.
Consequences
The application protocol instance < arg > is unavailable.
Probable causes
The option holding the transport is not installed or the application
name is faulty.
Recommended actions
1. Install the option.
2. Change the name of the transport in the configuration.
71397, No application protocol
Description
The application protocol < arg > is missing or the name is faulty.
Consequences
The application instance < arg > is unavailable.
Probable causes
The option holding the application protocol is not installed or the
protocol name is faulty.
Recommended actions
1. Install the option.
2. Change the name of the application protocol.
71398, Communication error from bosv24
Description
No response from the serial line.
Recommended actions
Check the device or connection.
71399, Communication error from bosv24
Description
Not possible to deliver the received message.
Recommended actions
Check the communication flow.
71400, Communication error from bosv24
Description
The response from the device has an invalid frame sequence.
Recommended actions
Check for noise on the serial line.
71401, No option exist for the < arg > Fieldbus
Adapter
Description
A < arg > Fieldbus Adapter has been found, but no option has been
installed.
Consequences
No communication on < arg > Fieldbus Adapter is possible. There
may be consequential errors from configuring when no such option has
been installed.
Probable causes
An attempt may have been made to add the < arg > Fieldbus Adapter
functionality, without installing the option correctly.
Recommended actions
If the < arg > Fieldbus Adapter option is required: configure a new
system with this option, and install the system.
71402, Duplicated address on the arg I/O bus
Description
The arg I/O bus address is duplicated on the network.
Conflicting address < arg >.
Consequences
No communication on the arg I/O bus is possible.
Recommended actions
1. Change the address on the conflicting I/O unit (or physically
disconnect the I/O unit) or change the address for the arg I/O bus.
2. Restart the system.
71403, The interval time is invalid
Description
For the DeviceNet unit type < arg > the connection arg interval time is
invalid.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 337
|
6 Trouble shooting by Event log
334
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71385, Request message resource exhausted
Description
Unable to handle more concurrent IO requests.
Out of concurrent I/O request using delay, pulse, or timeout argument.
Consequences
I/O request cannot be fulfilled.
Probable causes
To many I/O instructions with pulse or delay argument.
To many process instructions with pulse, delay or timeout.
Recommended actions
1. Reduce the number of concurrent I/O instructions with pulse or
delay argument.
2. Reduce the number of concurrent process instructions that use pulse,
delay or timeout argument.
71386, DeviceNet Quick Connect not supported
Description
The unit type < arg > may not be connected to the DeviceNet bus as a
Quick Connect I/O unit.
Consequences
This unit type has been rejected, and no functions depending on this
unit type will work.
Probable causes
The unit connected may be of a too early version.
Recommended actions
1. Disable the Quick Connect configuration parameter.
2. Replace the DeviceNet master/slave board with a later version.
71389, Configuration file error
Description
Errors occurred during loading of configuration data.
All configuration errors are placed in the cfg Event Log.
Consequences
The configuration in file will not be installed.
Recommended actions
View the errors in the cfg Event log.
71390, The DeviceNet bus have recovered from
bus off
Description
The DeviceNet bus < arg > have recovered from bus off state.
71391, System Signal configuration
Description
There was an error during the configuration of a System Input/Output
Signal.
System I/O name: arg
Consequences
The system will go to state SYS FAIL.
Probable causes
All errors during configuration of System Input/Output Signals are
considered fatal and the system will go to state SYS FAIL.
Recommended actions
1. Check the connection of the Unit to which the System Signal is
connected.
2. Check the configuration of the I/O unit.
71392, Invalid output size
Description
On DeviceNet I/O unit < arg > the connection 1 output size < arg > does
not match the I/O unit. When using strobe connection the only valid
output size are 1 or -1.
Recommended actions
1. Change size in configuration.
2. Check module.
3. Use DN_GENERIC unit type.
71393, Error when allocating generic size
Description
Failed to allocate generic arg size (-1) on DeviceNet I/O unit < arg >.
Probable causes
The DeviceNet I/O unit < arg > cannot be configured with unit type
DN_GENERIC or with a generic arg size (-1).
Recommended actions
1. Update your current unit type configuration with new arg size.
2. Do not use DN_GENERIC unit type.
71394, Invalid physical communication channel
Description
The communication channel arg is out of range.
Consequences
The communication channel arg is unavailable.
Probable causes
Option not installed or the communication channel < arg > is out of
range.
Recommended actions
1. Check the allowed minimum and maximum of connectors.
6 Trouble shooting by Event log
335
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
2. Check options required.
71395, No transport protocol
Description
The transport protocol < arg > for channel < arg > is missing.
Consequences
The transport instance < arg > is unavailable.
Probable causes
The option holding the transport protocol < arg > is not installed or the
protocol name is faulty.
Recommended actions
1. Install missing option.
2. Change the transport protocol name.
71396, No transmission protocol
Description
The transport protocol < arg > is missing or the name of the transport
protocol is faulty for < arg >.
Consequences
The application protocol instance < arg > is unavailable.
Probable causes
The option holding the transport is not installed or the application
name is faulty.
Recommended actions
1. Install the option.
2. Change the name of the transport in the configuration.
71397, No application protocol
Description
The application protocol < arg > is missing or the name is faulty.
Consequences
The application instance < arg > is unavailable.
Probable causes
The option holding the application protocol is not installed or the
protocol name is faulty.
Recommended actions
1. Install the option.
2. Change the name of the application protocol.
71398, Communication error from bosv24
Description
No response from the serial line.
Recommended actions
Check the device or connection.
71399, Communication error from bosv24
Description
Not possible to deliver the received message.
Recommended actions
Check the communication flow.
71400, Communication error from bosv24
Description
The response from the device has an invalid frame sequence.
Recommended actions
Check for noise on the serial line.
71401, No option exist for the < arg > Fieldbus
Adapter
Description
A < arg > Fieldbus Adapter has been found, but no option has been
installed.
Consequences
No communication on < arg > Fieldbus Adapter is possible. There
may be consequential errors from configuring when no such option has
been installed.
Probable causes
An attempt may have been made to add the < arg > Fieldbus Adapter
functionality, without installing the option correctly.
Recommended actions
If the < arg > Fieldbus Adapter option is required: configure a new
system with this option, and install the system.
71402, Duplicated address on the arg I/O bus
Description
The arg I/O bus address is duplicated on the network.
Conflicting address < arg >.
Consequences
No communication on the arg I/O bus is possible.
Recommended actions
1. Change the address on the conflicting I/O unit (or physically
disconnect the I/O unit) or change the address for the arg I/O bus.
2. Restart the system.
71403, The interval time is invalid
Description
For the DeviceNet unit type < arg > the connection arg interval time is
invalid.
6 Trouble shooting by Event log
336
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The interval time have a lower value than the production inhibit time.
Recommended actions
Change the connection arg interval time to be higher than the
production inhibit time for the unit type < arg > in the I/O configuration.
71404, Invalid input/output size
Description
The I/O unit < arg > have a invalid value (zero) for the input or output
size.
Recommended actions
Change the input/output size to a value greater value then zero.
71405, Duplicate I/O unit mapping
Description
The I/O signal < arg > has the same unit mapping as I/O signal < arg >.
Consequences
Mapping more than one I/O signal against the same bit(s) in the I/O
unit map can cause unpredictable values for these I/O signals since
their order of evaluation cannot be controlled. E.g. if an inverted group
output I/O signal is mapped to the same bits as some digital output I/O
signals, the status of these bits are depending on the order the I/O
signals are set.
Recommended actions
It is highly recommended that mapping of several I/O signals to the
same bit(s) is avoided.
71406, Communication established on
DeviceNet bus
Description
The DeviceNet bus < arg > has established communication.
71407, Route interface not found
Description
The route interface < arg > for I/O bus < arg > is not found in the system.
Consequences
The route is not available. Messages to devices connected to < arg >
will not forwarded.
Probable causes
The I/O bus < arg > not defined or spelled wrong.
Recommended actions
Change the I/O bus identifier.
71408, Route port number out of range
Description
The given port number arg of route < arg > is outside its range.
Consequences
The route is not available. Messages to devices connected to < arg >
will not be forwarded.
Probable causes
The number arg is outside its range.
Recommended actions
Change port number.
71409, Not able to add a port to arg
Description
Not able to define port arg of route < arg > due to lack of resources.
Consequences
The route is not available. Messages to devices connected to port
argarg is not forwared.
Probable causes
The < arg > doesn't support this many ports.
Recommended actions
When possible reduce the number of ports or report the problem to
ABB.
71410, CIP route option not installed
Description
The CIP route option is not enabled since it was not selected at system
creation.
Consequences
Any CIP route definitions will be omitted.
Probable causes
The CIP route option is not installed in the system.
Recommended actions
Create and install a system with the CIP route option.
71411, Out of route resources
Description
Not able to add anymore routes due to no more route resources in the
system.
Consequences
Route < arg > will not be added to the system.
Probable causes
Too many routes have been defined. The system only allows arg
routes.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 338
|
6 Trouble shooting by Event log
335
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
2. Check options required.
71395, No transport protocol
Description
The transport protocol < arg > for channel < arg > is missing.
Consequences
The transport instance < arg > is unavailable.
Probable causes
The option holding the transport protocol < arg > is not installed or the
protocol name is faulty.
Recommended actions
1. Install missing option.
2. Change the transport protocol name.
71396, No transmission protocol
Description
The transport protocol < arg > is missing or the name of the transport
protocol is faulty for < arg >.
Consequences
The application protocol instance < arg > is unavailable.
Probable causes
The option holding the transport is not installed or the application
name is faulty.
Recommended actions
1. Install the option.
2. Change the name of the transport in the configuration.
71397, No application protocol
Description
The application protocol < arg > is missing or the name is faulty.
Consequences
The application instance < arg > is unavailable.
Probable causes
The option holding the application protocol is not installed or the
protocol name is faulty.
Recommended actions
1. Install the option.
2. Change the name of the application protocol.
71398, Communication error from bosv24
Description
No response from the serial line.
Recommended actions
Check the device or connection.
71399, Communication error from bosv24
Description
Not possible to deliver the received message.
Recommended actions
Check the communication flow.
71400, Communication error from bosv24
Description
The response from the device has an invalid frame sequence.
Recommended actions
Check for noise on the serial line.
71401, No option exist for the < arg > Fieldbus
Adapter
Description
A < arg > Fieldbus Adapter has been found, but no option has been
installed.
Consequences
No communication on < arg > Fieldbus Adapter is possible. There
may be consequential errors from configuring when no such option has
been installed.
Probable causes
An attempt may have been made to add the < arg > Fieldbus Adapter
functionality, without installing the option correctly.
Recommended actions
If the < arg > Fieldbus Adapter option is required: configure a new
system with this option, and install the system.
71402, Duplicated address on the arg I/O bus
Description
The arg I/O bus address is duplicated on the network.
Conflicting address < arg >.
Consequences
No communication on the arg I/O bus is possible.
Recommended actions
1. Change the address on the conflicting I/O unit (or physically
disconnect the I/O unit) or change the address for the arg I/O bus.
2. Restart the system.
71403, The interval time is invalid
Description
For the DeviceNet unit type < arg > the connection arg interval time is
invalid.
6 Trouble shooting by Event log
336
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The interval time have a lower value than the production inhibit time.
Recommended actions
Change the connection arg interval time to be higher than the
production inhibit time for the unit type < arg > in the I/O configuration.
71404, Invalid input/output size
Description
The I/O unit < arg > have a invalid value (zero) for the input or output
size.
Recommended actions
Change the input/output size to a value greater value then zero.
71405, Duplicate I/O unit mapping
Description
The I/O signal < arg > has the same unit mapping as I/O signal < arg >.
Consequences
Mapping more than one I/O signal against the same bit(s) in the I/O
unit map can cause unpredictable values for these I/O signals since
their order of evaluation cannot be controlled. E.g. if an inverted group
output I/O signal is mapped to the same bits as some digital output I/O
signals, the status of these bits are depending on the order the I/O
signals are set.
Recommended actions
It is highly recommended that mapping of several I/O signals to the
same bit(s) is avoided.
71406, Communication established on
DeviceNet bus
Description
The DeviceNet bus < arg > has established communication.
71407, Route interface not found
Description
The route interface < arg > for I/O bus < arg > is not found in the system.
Consequences
The route is not available. Messages to devices connected to < arg >
will not forwarded.
Probable causes
The I/O bus < arg > not defined or spelled wrong.
Recommended actions
Change the I/O bus identifier.
71408, Route port number out of range
Description
The given port number arg of route < arg > is outside its range.
Consequences
The route is not available. Messages to devices connected to < arg >
will not be forwarded.
Probable causes
The number arg is outside its range.
Recommended actions
Change port number.
71409, Not able to add a port to arg
Description
Not able to define port arg of route < arg > due to lack of resources.
Consequences
The route is not available. Messages to devices connected to port
argarg is not forwared.
Probable causes
The < arg > doesn't support this many ports.
Recommended actions
When possible reduce the number of ports or report the problem to
ABB.
71410, CIP route option not installed
Description
The CIP route option is not enabled since it was not selected at system
creation.
Consequences
Any CIP route definitions will be omitted.
Probable causes
The CIP route option is not installed in the system.
Recommended actions
Create and install a system with the CIP route option.
71411, Out of route resources
Description
Not able to add anymore routes due to no more route resources in the
system.
Consequences
Route < arg > will not be added to the system.
Probable causes
Too many routes have been defined. The system only allows arg
routes.
6 Trouble shooting by Event log
337
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reduce the number of routes.
71412, The DeviceNet bus has regained the bus
power
Description
The DeviceNet bus < arg > has regained the 24 V bus power.
71413, Dengensha option not installed
Description
The Dengensha option has not been correctly installed in the system.
Recommended actions
Reinstall the system using a proper key containing the Dengensha
option.
71414, Concurrent changes of signal value
Description
Concurrent changes of I/O signal < arg > value have been detected.
Consequences
A signal value change of I/O signal < arg > is aborted due to another
value change of the same I/O signal.
Probable causes
The concurrent value change is due to an undesired signal change
sequence in a program. Multiple changes of I/O signal arg might
appear when a I/O signal is pulsed, e.g.
SetDO arg , 0;
PulseDO /High /PLength = 0.01, arg ;
WaitTime 0.01;
SetDO arg , 1;
The I/O signal arg will be 1 at the end, but at rare occasions there will
not be any visible pulse. This type of sequence should be avoided.
Recommended actions
Verify that concurrent value changes are desired of I/O signal
< arg >, otherwise modify the signal change sequence.
71415, No bus power
Description
The 24 V power to the DeviceNet Lean bus is missing.
Consequences
No communication on the DeviceNet Lean bus is possible.
Probable causes
The power supply unit, cabling, input voltage to the power supply or
the output load may cause the power loss. See the trouble shooting
section in the manual.
Recommended actions
1. Make sure that the DeviceNet Lean bus contact is connected.
2. Check all cabling to the power supply unit.
3. Measure the output and input voltage levels.
4. Replace the faulty unit if required.
71416, Bus power restored
Description
The 24 V power to the DeviceNet Lean bus is restored.
71417, DeviceNet Lean hardware missing
Description
The DSQC 572 hardware adapter with the DeviceNet Lean bus contact
is missing.
Consequences
No communication on the DeviceNet Lean bus is possible.
Probable causes
DSQC 572 is missing or the cabling between the main computer unit
and DSQC 572 is not inserted.
Recommended actions
1. Check all cabling.
2. Replace the faulty DSQC 572 hardware adapter if required.
71418, Not allowed vendor
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not
supported. Reported vendor ID was arg , expected arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
1. Remove the I/O unit from the configuration.
2. Replace the I/O unit with a supported type.
71419, Not allowed unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not a
supported DeviceNet Lean module type.
Consequences
No communication to the I/O unit is possible.
Recommended actions
1. Remove the I/O unit from the configuration.
2. Replace the I/O unit with a supported I/O unit type.
71420, Wrong unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not of the
same type as configured.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 339
|
6 Trouble shooting by Event log
336
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The interval time have a lower value than the production inhibit time.
Recommended actions
Change the connection arg interval time to be higher than the
production inhibit time for the unit type < arg > in the I/O configuration.
71404, Invalid input/output size
Description
The I/O unit < arg > have a invalid value (zero) for the input or output
size.
Recommended actions
Change the input/output size to a value greater value then zero.
71405, Duplicate I/O unit mapping
Description
The I/O signal < arg > has the same unit mapping as I/O signal < arg >.
Consequences
Mapping more than one I/O signal against the same bit(s) in the I/O
unit map can cause unpredictable values for these I/O signals since
their order of evaluation cannot be controlled. E.g. if an inverted group
output I/O signal is mapped to the same bits as some digital output I/O
signals, the status of these bits are depending on the order the I/O
signals are set.
Recommended actions
It is highly recommended that mapping of several I/O signals to the
same bit(s) is avoided.
71406, Communication established on
DeviceNet bus
Description
The DeviceNet bus < arg > has established communication.
71407, Route interface not found
Description
The route interface < arg > for I/O bus < arg > is not found in the system.
Consequences
The route is not available. Messages to devices connected to < arg >
will not forwarded.
Probable causes
The I/O bus < arg > not defined or spelled wrong.
Recommended actions
Change the I/O bus identifier.
71408, Route port number out of range
Description
The given port number arg of route < arg > is outside its range.
Consequences
The route is not available. Messages to devices connected to < arg >
will not be forwarded.
Probable causes
The number arg is outside its range.
Recommended actions
Change port number.
71409, Not able to add a port to arg
Description
Not able to define port arg of route < arg > due to lack of resources.
Consequences
The route is not available. Messages to devices connected to port
argarg is not forwared.
Probable causes
The < arg > doesn't support this many ports.
Recommended actions
When possible reduce the number of ports or report the problem to
ABB.
71410, CIP route option not installed
Description
The CIP route option is not enabled since it was not selected at system
creation.
Consequences
Any CIP route definitions will be omitted.
Probable causes
The CIP route option is not installed in the system.
Recommended actions
Create and install a system with the CIP route option.
71411, Out of route resources
Description
Not able to add anymore routes due to no more route resources in the
system.
Consequences
Route < arg > will not be added to the system.
Probable causes
Too many routes have been defined. The system only allows arg
routes.
6 Trouble shooting by Event log
337
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reduce the number of routes.
71412, The DeviceNet bus has regained the bus
power
Description
The DeviceNet bus < arg > has regained the 24 V bus power.
71413, Dengensha option not installed
Description
The Dengensha option has not been correctly installed in the system.
Recommended actions
Reinstall the system using a proper key containing the Dengensha
option.
71414, Concurrent changes of signal value
Description
Concurrent changes of I/O signal < arg > value have been detected.
Consequences
A signal value change of I/O signal < arg > is aborted due to another
value change of the same I/O signal.
Probable causes
The concurrent value change is due to an undesired signal change
sequence in a program. Multiple changes of I/O signal arg might
appear when a I/O signal is pulsed, e.g.
SetDO arg , 0;
PulseDO /High /PLength = 0.01, arg ;
WaitTime 0.01;
SetDO arg , 1;
The I/O signal arg will be 1 at the end, but at rare occasions there will
not be any visible pulse. This type of sequence should be avoided.
Recommended actions
Verify that concurrent value changes are desired of I/O signal
< arg >, otherwise modify the signal change sequence.
71415, No bus power
Description
The 24 V power to the DeviceNet Lean bus is missing.
Consequences
No communication on the DeviceNet Lean bus is possible.
Probable causes
The power supply unit, cabling, input voltage to the power supply or
the output load may cause the power loss. See the trouble shooting
section in the manual.
Recommended actions
1. Make sure that the DeviceNet Lean bus contact is connected.
2. Check all cabling to the power supply unit.
3. Measure the output and input voltage levels.
4. Replace the faulty unit if required.
71416, Bus power restored
Description
The 24 V power to the DeviceNet Lean bus is restored.
71417, DeviceNet Lean hardware missing
Description
The DSQC 572 hardware adapter with the DeviceNet Lean bus contact
is missing.
Consequences
No communication on the DeviceNet Lean bus is possible.
Probable causes
DSQC 572 is missing or the cabling between the main computer unit
and DSQC 572 is not inserted.
Recommended actions
1. Check all cabling.
2. Replace the faulty DSQC 572 hardware adapter if required.
71418, Not allowed vendor
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not
supported. Reported vendor ID was arg , expected arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
1. Remove the I/O unit from the configuration.
2. Replace the I/O unit with a supported type.
71419, Not allowed unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not a
supported DeviceNet Lean module type.
Consequences
No communication to the I/O unit is possible.
Recommended actions
1. Remove the I/O unit from the configuration.
2. Replace the I/O unit with a supported I/O unit type.
71420, Wrong unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not of the
same type as configured.
6 Trouble shooting by Event log
338
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Reported product code was arg , expected was arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
Change the I/O unit configuration.
71421, Duplicated address on the DeviceNet
Lean bus
Description
The reserved address arg for the DeviceNet Lean master is occupied
by an another I/O unit on the network.
Recommended actions
1. Change the address on the conflicting I/O unit.
2. Disconnect the I/O unit occupying the masters address from the
network.
71422, High load on the DeviceNet Lean bus
Description
The amount of traffic on the DeviceNet Lean bus is too high, or the
system is too busy to handle all messages on the DeviceNet Lean bus.
Consequences
I/O data might be lost or delayed.
Recommended actions
1. Change the production inhibit parameter on all configured I/O units.
2. Reduce system load.
71423, Minor error on the DeviceNet Lean bus
Description
A minor amount of communication errors have occurred on the
DeviceNet Lean bus.
Consequences
I/O data might be lost or delayed.
Recommended actions
Check all cabling
71424, DeviceNet Lean bus off
Description
A major amount of errors has occurred on the DeviceNet Lean bus.
The bus will try to recover when possible.
Consequences
No data exchange with configured I/O units will be possible.
Recommended actions
Check all cabling
71425, DeviceNet Lean too many I/O units
Description
There are too many I/O units configured on the DeviceNet Lean bus.
The maximum allowed number is arg . The I/O unit < arg > is rejected.
Consequences
No data exchange with I/O unit < arg > will be possible.
Recommended actions
Remove the I/O unit from I/O configuration.
71426, DeviceNet Lean bus regained
Description
The operating mode of the DeviceNet Lean bus has changed to state
running.
Consequences
Data exchange with configured I/O units will be possible.
71427, DeviceNet Lean option key missing
Description
The option key needed to run DeviceNet Lean on the IRC5 controller
was not detected.
Consequences
No communication on I/O bus DeviceNet Lean is possible.
Probable causes
An attempt may have been made to add the DeviceNet Lean
functionality, without installing the option correctly.
Recommended actions
1. Configure a new system with the DeviceNet Lean option, and install
the system.
2. If DeviceNet Lean is not required: configure a new system without
this option, and install that system.
71428, DeviceNet Lean I/O unit configured
Description
A new I/O unit has been found and configured on the DeviceNet Lean
bus.
Unit name: arg
Unit address: arg
Input bytes / Output bytes: arg
Vendor ID: arg
Product code: arg
Recommended actions
1. Restart the IRC5 controller to activate the I/O unit configuration.
2. Edit or delete the configuration.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 340
|
6 Trouble shooting by Event log
337
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reduce the number of routes.
71412, The DeviceNet bus has regained the bus
power
Description
The DeviceNet bus < arg > has regained the 24 V bus power.
71413, Dengensha option not installed
Description
The Dengensha option has not been correctly installed in the system.
Recommended actions
Reinstall the system using a proper key containing the Dengensha
option.
71414, Concurrent changes of signal value
Description
Concurrent changes of I/O signal < arg > value have been detected.
Consequences
A signal value change of I/O signal < arg > is aborted due to another
value change of the same I/O signal.
Probable causes
The concurrent value change is due to an undesired signal change
sequence in a program. Multiple changes of I/O signal arg might
appear when a I/O signal is pulsed, e.g.
SetDO arg , 0;
PulseDO /High /PLength = 0.01, arg ;
WaitTime 0.01;
SetDO arg , 1;
The I/O signal arg will be 1 at the end, but at rare occasions there will
not be any visible pulse. This type of sequence should be avoided.
Recommended actions
Verify that concurrent value changes are desired of I/O signal
< arg >, otherwise modify the signal change sequence.
71415, No bus power
Description
The 24 V power to the DeviceNet Lean bus is missing.
Consequences
No communication on the DeviceNet Lean bus is possible.
Probable causes
The power supply unit, cabling, input voltage to the power supply or
the output load may cause the power loss. See the trouble shooting
section in the manual.
Recommended actions
1. Make sure that the DeviceNet Lean bus contact is connected.
2. Check all cabling to the power supply unit.
3. Measure the output and input voltage levels.
4. Replace the faulty unit if required.
71416, Bus power restored
Description
The 24 V power to the DeviceNet Lean bus is restored.
71417, DeviceNet Lean hardware missing
Description
The DSQC 572 hardware adapter with the DeviceNet Lean bus contact
is missing.
Consequences
No communication on the DeviceNet Lean bus is possible.
Probable causes
DSQC 572 is missing or the cabling between the main computer unit
and DSQC 572 is not inserted.
Recommended actions
1. Check all cabling.
2. Replace the faulty DSQC 572 hardware adapter if required.
71418, Not allowed vendor
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not
supported. Reported vendor ID was arg , expected arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
1. Remove the I/O unit from the configuration.
2. Replace the I/O unit with a supported type.
71419, Not allowed unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not a
supported DeviceNet Lean module type.
Consequences
No communication to the I/O unit is possible.
Recommended actions
1. Remove the I/O unit from the configuration.
2. Replace the I/O unit with a supported I/O unit type.
71420, Wrong unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not of the
same type as configured.
6 Trouble shooting by Event log
338
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Reported product code was arg , expected was arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
Change the I/O unit configuration.
71421, Duplicated address on the DeviceNet
Lean bus
Description
The reserved address arg for the DeviceNet Lean master is occupied
by an another I/O unit on the network.
Recommended actions
1. Change the address on the conflicting I/O unit.
2. Disconnect the I/O unit occupying the masters address from the
network.
71422, High load on the DeviceNet Lean bus
Description
The amount of traffic on the DeviceNet Lean bus is too high, or the
system is too busy to handle all messages on the DeviceNet Lean bus.
Consequences
I/O data might be lost or delayed.
Recommended actions
1. Change the production inhibit parameter on all configured I/O units.
2. Reduce system load.
71423, Minor error on the DeviceNet Lean bus
Description
A minor amount of communication errors have occurred on the
DeviceNet Lean bus.
Consequences
I/O data might be lost or delayed.
Recommended actions
Check all cabling
71424, DeviceNet Lean bus off
Description
A major amount of errors has occurred on the DeviceNet Lean bus.
The bus will try to recover when possible.
Consequences
No data exchange with configured I/O units will be possible.
Recommended actions
Check all cabling
71425, DeviceNet Lean too many I/O units
Description
There are too many I/O units configured on the DeviceNet Lean bus.
The maximum allowed number is arg . The I/O unit < arg > is rejected.
Consequences
No data exchange with I/O unit < arg > will be possible.
Recommended actions
Remove the I/O unit from I/O configuration.
71426, DeviceNet Lean bus regained
Description
The operating mode of the DeviceNet Lean bus has changed to state
running.
Consequences
Data exchange with configured I/O units will be possible.
71427, DeviceNet Lean option key missing
Description
The option key needed to run DeviceNet Lean on the IRC5 controller
was not detected.
Consequences
No communication on I/O bus DeviceNet Lean is possible.
Probable causes
An attempt may have been made to add the DeviceNet Lean
functionality, without installing the option correctly.
Recommended actions
1. Configure a new system with the DeviceNet Lean option, and install
the system.
2. If DeviceNet Lean is not required: configure a new system without
this option, and install that system.
71428, DeviceNet Lean I/O unit configured
Description
A new I/O unit has been found and configured on the DeviceNet Lean
bus.
Unit name: arg
Unit address: arg
Input bytes / Output bytes: arg
Vendor ID: arg
Product code: arg
Recommended actions
1. Restart the IRC5 controller to activate the I/O unit configuration.
2. Edit or delete the configuration.
6 Trouble shooting by Event log
339
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71429, No configuration in the Profinet PCI
board
Description
There is no bus configuration in the Profinet PCI board.
Recommended actions
Download a configuration to the board using an external software tool.
71430, Incompatible firmware in Profinet board
Description
The current firmware in the Profinet PCI board, version < arg >, is
incompatible with this RobotWare release.
Consequences
No communication on Profinet is possible.
Recommended actions
Download firmware of version < arg > to the Profinet PCI board using
the Firmware Loader in Siemens Step7. Contact ABB support for more
information about how to do that.
71431, Configuration update in progress
Description
No configuration found in the Profinet PCI board or an external
software tool has stopped the Profinet bus.
DO NOT restart the IRC5 controller until the Profinet configuration is
fully downloaded.
Consequences
No connection to I/O units will be possible.
Recommended actions
Use an external software tool to download a configuration and to start
the Profinet bus.
71432, Profinet hardware exception
Description
The Profinet PCI board has reported an internal software exception in
its firmware. The exception occurred before this restart. Follow the
actions steps below to recover from this error state.
Consequences
No connection to I/O units will be possible.
Probable causes
A configuration download from an external Profinet tool might have
been interrupted before it was completed.
Recommended actions
1. Clear all configuration data in the Profinet PCI board using an
external software tool.
2. Reconfigure the Profinet PCI board using an external software tool.
3. Warmtart the IRC5 controller.
71433, No contact with Profinet PCI board
Description
The Profinet PCI board could not be contacted. Error code returned
arg .
Consequences
No connection to I/O units will be possible.
Probable causes
1. The Profinet board is missing or malfunctioning.
2. A new configuration is being downloaded from an external software
tool.
Recommended actions
Make sure the Profinet PCI board is installed in the IRC5 controller.
71434, Profinet bus stopped
Description
A new Profinet configuration has been downloaded using an external
software configuration tool. Since the new configuration has major
changes, the IRC5 controller could not reuse the I/O configuration in
the IRC5 controller. A restart is needed.
Consequences
No connection to I/O units will be possible.
Recommended actions
Restart the IRC5 controller.
71435, Profinet I/O unit not configured
Description
A Profinet I/O unit at address < arg > has generated an alarm. The I/O
unit is configured in the Profinet PCI board, but not in the IRC5
controller.
The I/O unit needs to be configured in the IRC5 controller for the alarm
to be handled.
Consequences
No connection to the I/O unit will be possible.
Recommended actions
1. Add the I/O unit to the IRC5 controller I/O configuration.
2. Remove the configuration in the Profinet PCI board.
71436, Profinet configuration missing
Description
The I/O unit < arg > is configured in the IRC5 controller, but is not
found in the Profinet PCI board configuration.
Consequences
No connection to the I/O unit will be possible.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 341
|
6 Trouble shooting by Event log
338
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Reported product code was arg , expected was arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
Change the I/O unit configuration.
71421, Duplicated address on the DeviceNet
Lean bus
Description
The reserved address arg for the DeviceNet Lean master is occupied
by an another I/O unit on the network.
Recommended actions
1. Change the address on the conflicting I/O unit.
2. Disconnect the I/O unit occupying the masters address from the
network.
71422, High load on the DeviceNet Lean bus
Description
The amount of traffic on the DeviceNet Lean bus is too high, or the
system is too busy to handle all messages on the DeviceNet Lean bus.
Consequences
I/O data might be lost or delayed.
Recommended actions
1. Change the production inhibit parameter on all configured I/O units.
2. Reduce system load.
71423, Minor error on the DeviceNet Lean bus
Description
A minor amount of communication errors have occurred on the
DeviceNet Lean bus.
Consequences
I/O data might be lost or delayed.
Recommended actions
Check all cabling
71424, DeviceNet Lean bus off
Description
A major amount of errors has occurred on the DeviceNet Lean bus.
The bus will try to recover when possible.
Consequences
No data exchange with configured I/O units will be possible.
Recommended actions
Check all cabling
71425, DeviceNet Lean too many I/O units
Description
There are too many I/O units configured on the DeviceNet Lean bus.
The maximum allowed number is arg . The I/O unit < arg > is rejected.
Consequences
No data exchange with I/O unit < arg > will be possible.
Recommended actions
Remove the I/O unit from I/O configuration.
71426, DeviceNet Lean bus regained
Description
The operating mode of the DeviceNet Lean bus has changed to state
running.
Consequences
Data exchange with configured I/O units will be possible.
71427, DeviceNet Lean option key missing
Description
The option key needed to run DeviceNet Lean on the IRC5 controller
was not detected.
Consequences
No communication on I/O bus DeviceNet Lean is possible.
Probable causes
An attempt may have been made to add the DeviceNet Lean
functionality, without installing the option correctly.
Recommended actions
1. Configure a new system with the DeviceNet Lean option, and install
the system.
2. If DeviceNet Lean is not required: configure a new system without
this option, and install that system.
71428, DeviceNet Lean I/O unit configured
Description
A new I/O unit has been found and configured on the DeviceNet Lean
bus.
Unit name: arg
Unit address: arg
Input bytes / Output bytes: arg
Vendor ID: arg
Product code: arg
Recommended actions
1. Restart the IRC5 controller to activate the I/O unit configuration.
2. Edit or delete the configuration.
6 Trouble shooting by Event log
339
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71429, No configuration in the Profinet PCI
board
Description
There is no bus configuration in the Profinet PCI board.
Recommended actions
Download a configuration to the board using an external software tool.
71430, Incompatible firmware in Profinet board
Description
The current firmware in the Profinet PCI board, version < arg >, is
incompatible with this RobotWare release.
Consequences
No communication on Profinet is possible.
Recommended actions
Download firmware of version < arg > to the Profinet PCI board using
the Firmware Loader in Siemens Step7. Contact ABB support for more
information about how to do that.
71431, Configuration update in progress
Description
No configuration found in the Profinet PCI board or an external
software tool has stopped the Profinet bus.
DO NOT restart the IRC5 controller until the Profinet configuration is
fully downloaded.
Consequences
No connection to I/O units will be possible.
Recommended actions
Use an external software tool to download a configuration and to start
the Profinet bus.
71432, Profinet hardware exception
Description
The Profinet PCI board has reported an internal software exception in
its firmware. The exception occurred before this restart. Follow the
actions steps below to recover from this error state.
Consequences
No connection to I/O units will be possible.
Probable causes
A configuration download from an external Profinet tool might have
been interrupted before it was completed.
Recommended actions
1. Clear all configuration data in the Profinet PCI board using an
external software tool.
2. Reconfigure the Profinet PCI board using an external software tool.
3. Warmtart the IRC5 controller.
71433, No contact with Profinet PCI board
Description
The Profinet PCI board could not be contacted. Error code returned
arg .
Consequences
No connection to I/O units will be possible.
Probable causes
1. The Profinet board is missing or malfunctioning.
2. A new configuration is being downloaded from an external software
tool.
Recommended actions
Make sure the Profinet PCI board is installed in the IRC5 controller.
71434, Profinet bus stopped
Description
A new Profinet configuration has been downloaded using an external
software configuration tool. Since the new configuration has major
changes, the IRC5 controller could not reuse the I/O configuration in
the IRC5 controller. A restart is needed.
Consequences
No connection to I/O units will be possible.
Recommended actions
Restart the IRC5 controller.
71435, Profinet I/O unit not configured
Description
A Profinet I/O unit at address < arg > has generated an alarm. The I/O
unit is configured in the Profinet PCI board, but not in the IRC5
controller.
The I/O unit needs to be configured in the IRC5 controller for the alarm
to be handled.
Consequences
No connection to the I/O unit will be possible.
Recommended actions
1. Add the I/O unit to the IRC5 controller I/O configuration.
2. Remove the configuration in the Profinet PCI board.
71436, Profinet configuration missing
Description
The I/O unit < arg > is configured in the IRC5 controller, but is not
found in the Profinet PCI board configuration.
Consequences
No connection to the I/O unit will be possible.
6 Trouble shooting by Event log
340
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Add the configuration for the I/O unit in the Profinet PCI board
using an external configuration tool.
2. Remove the I/O unit configuration from the IRC5 controller
configuration.
71437, Profinet internal slave config warning
Description
The Profinet internal slave is configured in the IRC5 controller with
the following modules:
arg The connecting Profinet master have an different module
configuration.
Mismatch detected in slot arg .
Consequences
The connection attempt is rejected.
Recommended actions
1. Reconfigure the connecting Profinet master.
2. Reconfigure the Profinet internal slave in the IRC5 controller.
71438, Profinet internal slave configuration
warning
Description
The Profinet internal slave is configured in the IRC5 controller as a arg
byte input module in slot arg and a arg byte output module in slot arg ,
but the connecting Profinet master have a module configure in slot arg .
Consequences
The connection attempt is rejected.
Recommended actions
Reconfigure the connecting Profinet master.
71439, Profinet diagnostics received
Description
The I/O unit < arg > has reported diagnostic data in slot arg .
Use I/O unit specific documentation for more explaination on the
diagnostics data.
Data received:
arg
71440, Profinet configuration mismatch
Description
Profinet-IO routing has been configured using an external Profinet
configuration tool. To be able to use Profinet-IO routing on the IRC5
controller, the Profinet internal slave needs to be configured in the
IRC5 controller.
Consequences
No Profinet-IO routing will be possible.
Recommended actions
1. Add the Profinet internal slave to the I/O configuration.
2. Remove the Profinet-IO routing configuration from the DSQC 678.
71441, Profinet-IO routing warning
Description
Since Profinet-IO routing is configured on I/O unit < arg >, some data
bits might be dependent on the PLC connection status and operating
mode.
If the I/O unit < arg > has I/O signals mapped on digital output bits
controlled by the PLC, these I/O signals can be set by the IRC5
controller, but will not affect the I/O units output values.
Consequences
Some I/O signals might not be handled by the IRC5 controller.
Recommended actions
1. Configure write protection on digital outputs I/O signals mapped
by the IRC5 controller, but controlled by the PLC.
2. Name I/O signals to reflect the fact that they are controlled by the
PLC.
71442, Profinet option key missing
Description
The option needed to run Profinet on the IRC5 controller was not
detected.
Consequences
No communication on Profinet bus is possible.
Probable causes
An attempt may have been made to add the Profinet functionality,
without installing the option correctly.
Recommended actions
1. Configure a new system with the Profinet option, and install the
system.
2. If Profinet is not required, configure a new system without this
option, and install that system.
71443, Too many Profinet internal slaves
Description
There are too many Profinet internal slaves defined in the IRC5
controller.
Consequences
Profinet I/O unit < arg > will not be configured. No communication
with this I/O unit will be possible.
Probable causes
Profinet I/O unit < arg > is defined as an Profinet internal slave while
another Profinet internal slave has already been configured.
Recommended actions
Remove I/O unit < arg > from the configuration.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 342
|
6 Trouble shooting by Event log
339
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71429, No configuration in the Profinet PCI
board
Description
There is no bus configuration in the Profinet PCI board.
Recommended actions
Download a configuration to the board using an external software tool.
71430, Incompatible firmware in Profinet board
Description
The current firmware in the Profinet PCI board, version < arg >, is
incompatible with this RobotWare release.
Consequences
No communication on Profinet is possible.
Recommended actions
Download firmware of version < arg > to the Profinet PCI board using
the Firmware Loader in Siemens Step7. Contact ABB support for more
information about how to do that.
71431, Configuration update in progress
Description
No configuration found in the Profinet PCI board or an external
software tool has stopped the Profinet bus.
DO NOT restart the IRC5 controller until the Profinet configuration is
fully downloaded.
Consequences
No connection to I/O units will be possible.
Recommended actions
Use an external software tool to download a configuration and to start
the Profinet bus.
71432, Profinet hardware exception
Description
The Profinet PCI board has reported an internal software exception in
its firmware. The exception occurred before this restart. Follow the
actions steps below to recover from this error state.
Consequences
No connection to I/O units will be possible.
Probable causes
A configuration download from an external Profinet tool might have
been interrupted before it was completed.
Recommended actions
1. Clear all configuration data in the Profinet PCI board using an
external software tool.
2. Reconfigure the Profinet PCI board using an external software tool.
3. Warmtart the IRC5 controller.
71433, No contact with Profinet PCI board
Description
The Profinet PCI board could not be contacted. Error code returned
arg .
Consequences
No connection to I/O units will be possible.
Probable causes
1. The Profinet board is missing or malfunctioning.
2. A new configuration is being downloaded from an external software
tool.
Recommended actions
Make sure the Profinet PCI board is installed in the IRC5 controller.
71434, Profinet bus stopped
Description
A new Profinet configuration has been downloaded using an external
software configuration tool. Since the new configuration has major
changes, the IRC5 controller could not reuse the I/O configuration in
the IRC5 controller. A restart is needed.
Consequences
No connection to I/O units will be possible.
Recommended actions
Restart the IRC5 controller.
71435, Profinet I/O unit not configured
Description
A Profinet I/O unit at address < arg > has generated an alarm. The I/O
unit is configured in the Profinet PCI board, but not in the IRC5
controller.
The I/O unit needs to be configured in the IRC5 controller for the alarm
to be handled.
Consequences
No connection to the I/O unit will be possible.
Recommended actions
1. Add the I/O unit to the IRC5 controller I/O configuration.
2. Remove the configuration in the Profinet PCI board.
71436, Profinet configuration missing
Description
The I/O unit < arg > is configured in the IRC5 controller, but is not
found in the Profinet PCI board configuration.
Consequences
No connection to the I/O unit will be possible.
6 Trouble shooting by Event log
340
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Add the configuration for the I/O unit in the Profinet PCI board
using an external configuration tool.
2. Remove the I/O unit configuration from the IRC5 controller
configuration.
71437, Profinet internal slave config warning
Description
The Profinet internal slave is configured in the IRC5 controller with
the following modules:
arg The connecting Profinet master have an different module
configuration.
Mismatch detected in slot arg .
Consequences
The connection attempt is rejected.
Recommended actions
1. Reconfigure the connecting Profinet master.
2. Reconfigure the Profinet internal slave in the IRC5 controller.
71438, Profinet internal slave configuration
warning
Description
The Profinet internal slave is configured in the IRC5 controller as a arg
byte input module in slot arg and a arg byte output module in slot arg ,
but the connecting Profinet master have a module configure in slot arg .
Consequences
The connection attempt is rejected.
Recommended actions
Reconfigure the connecting Profinet master.
71439, Profinet diagnostics received
Description
The I/O unit < arg > has reported diagnostic data in slot arg .
Use I/O unit specific documentation for more explaination on the
diagnostics data.
Data received:
arg
71440, Profinet configuration mismatch
Description
Profinet-IO routing has been configured using an external Profinet
configuration tool. To be able to use Profinet-IO routing on the IRC5
controller, the Profinet internal slave needs to be configured in the
IRC5 controller.
Consequences
No Profinet-IO routing will be possible.
Recommended actions
1. Add the Profinet internal slave to the I/O configuration.
2. Remove the Profinet-IO routing configuration from the DSQC 678.
71441, Profinet-IO routing warning
Description
Since Profinet-IO routing is configured on I/O unit < arg >, some data
bits might be dependent on the PLC connection status and operating
mode.
If the I/O unit < arg > has I/O signals mapped on digital output bits
controlled by the PLC, these I/O signals can be set by the IRC5
controller, but will not affect the I/O units output values.
Consequences
Some I/O signals might not be handled by the IRC5 controller.
Recommended actions
1. Configure write protection on digital outputs I/O signals mapped
by the IRC5 controller, but controlled by the PLC.
2. Name I/O signals to reflect the fact that they are controlled by the
PLC.
71442, Profinet option key missing
Description
The option needed to run Profinet on the IRC5 controller was not
detected.
Consequences
No communication on Profinet bus is possible.
Probable causes
An attempt may have been made to add the Profinet functionality,
without installing the option correctly.
Recommended actions
1. Configure a new system with the Profinet option, and install the
system.
2. If Profinet is not required, configure a new system without this
option, and install that system.
71443, Too many Profinet internal slaves
Description
There are too many Profinet internal slaves defined in the IRC5
controller.
Consequences
Profinet I/O unit < arg > will not be configured. No communication
with this I/O unit will be possible.
Probable causes
Profinet I/O unit < arg > is defined as an Profinet internal slave while
another Profinet internal slave has already been configured.
Recommended actions
Remove I/O unit < arg > from the configuration.
6 Trouble shooting by Event log
341
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71444, Profinet diagnostics received
Description
The I/O unit < arg > has reported diagnostic data in slot arg .
arg
71445, Profinet PCI board error
Description
The Profinet PCI board could not be found.
Consequences
No connection to I/O units will be possible.
Probable causes
The Profinet PCI board is not installed or a 'reset to factory settings'
command has been performed. The 'reset to factory settings' command
demands another restart of the IRC5 controller in order to be
completed.
Recommended actions
1. Install the Profinet PCI board in the IRC5 controller.
2. Restart the IRC5 controller to perform the 'reset to factory settings'
command.
71446, Profinet configuration mismatch
Description
Configuration mismatch between the Fieldbus Adapter and the
connecting Profinet master in slot arg .
Consequences
The Fieldbus Adapter will indicate a diagnostic error and no
communication will be established between the Fieldbus Adapter and
the connecting Profinet master.
Probable causes
Mismatch of the data type/size in slot arg for the Profinet master
configuration. The expected data type/size is argarg bytes.
Recommended actions
Correct the data type/size in slot arg in the external configuration tool
or change the data size in the IRC5 controller configuration.
NOTE:
In the Profinet master configuration input data shall be in slot 1 and
output data in slot 2.
71447, Profinet internal slave error
Description
The I/O unit < arg > is configured as an internal slave. The unit address
must then be 0, but is configured to arg .
Consequences
The I/O unit < arg > will not be configured.
Recommended actions
Change the unit address to 0.
71448, I/O bus recovered from communication
failure
Description
The I/O bus < arg > has recover from the previous communication
failure.
71449, Too many fieldbus adapters configured
Description
Too many fieldbus adapters configured. It is only allowed to have one
fieldbus adapter configured.
Consequences
The fieldbus adapter < arg > has been rejected, and no functions
depending on it will work.
Recommended actions
1. Remove a fieldbus adapter in the configuration.
2. Restart the system.
71450, EtherNet/IP Master/Slave option not
installed
Description
A EtherNet/IP I/O bus is configured, but the EtherNet/IP Master/Slave
option has not been installed.
Consequences
No communication on the EtherNet/IP is possible. There may be
consequential errors from configuring EtherNet/IP when no such
option has been installed.
Probable causes
An attempt may have been made to add the EtherNet/IP functionality,
without installing the option correctly.
Recommended actions
1. If the EtherNet/IP option is required: configure a new system with
this option, and install the system.
2. If the EtherNet/IP option is not required: configure a new system
without this option, and install the system.
71451, Ethernet extra port option not installed
Description
A EtherNet/IP I/O bus is configured to use the extra Ethernet port, but
the Ethernet extra port option has not been installed.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
An attempt may have been made to add the EtherNet/IP functionality,
without installing the correct option.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 343
|
6 Trouble shooting by Event log
340
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Add the configuration for the I/O unit in the Profinet PCI board
using an external configuration tool.
2. Remove the I/O unit configuration from the IRC5 controller
configuration.
71437, Profinet internal slave config warning
Description
The Profinet internal slave is configured in the IRC5 controller with
the following modules:
arg The connecting Profinet master have an different module
configuration.
Mismatch detected in slot arg .
Consequences
The connection attempt is rejected.
Recommended actions
1. Reconfigure the connecting Profinet master.
2. Reconfigure the Profinet internal slave in the IRC5 controller.
71438, Profinet internal slave configuration
warning
Description
The Profinet internal slave is configured in the IRC5 controller as a arg
byte input module in slot arg and a arg byte output module in slot arg ,
but the connecting Profinet master have a module configure in slot arg .
Consequences
The connection attempt is rejected.
Recommended actions
Reconfigure the connecting Profinet master.
71439, Profinet diagnostics received
Description
The I/O unit < arg > has reported diagnostic data in slot arg .
Use I/O unit specific documentation for more explaination on the
diagnostics data.
Data received:
arg
71440, Profinet configuration mismatch
Description
Profinet-IO routing has been configured using an external Profinet
configuration tool. To be able to use Profinet-IO routing on the IRC5
controller, the Profinet internal slave needs to be configured in the
IRC5 controller.
Consequences
No Profinet-IO routing will be possible.
Recommended actions
1. Add the Profinet internal slave to the I/O configuration.
2. Remove the Profinet-IO routing configuration from the DSQC 678.
71441, Profinet-IO routing warning
Description
Since Profinet-IO routing is configured on I/O unit < arg >, some data
bits might be dependent on the PLC connection status and operating
mode.
If the I/O unit < arg > has I/O signals mapped on digital output bits
controlled by the PLC, these I/O signals can be set by the IRC5
controller, but will not affect the I/O units output values.
Consequences
Some I/O signals might not be handled by the IRC5 controller.
Recommended actions
1. Configure write protection on digital outputs I/O signals mapped
by the IRC5 controller, but controlled by the PLC.
2. Name I/O signals to reflect the fact that they are controlled by the
PLC.
71442, Profinet option key missing
Description
The option needed to run Profinet on the IRC5 controller was not
detected.
Consequences
No communication on Profinet bus is possible.
Probable causes
An attempt may have been made to add the Profinet functionality,
without installing the option correctly.
Recommended actions
1. Configure a new system with the Profinet option, and install the
system.
2. If Profinet is not required, configure a new system without this
option, and install that system.
71443, Too many Profinet internal slaves
Description
There are too many Profinet internal slaves defined in the IRC5
controller.
Consequences
Profinet I/O unit < arg > will not be configured. No communication
with this I/O unit will be possible.
Probable causes
Profinet I/O unit < arg > is defined as an Profinet internal slave while
another Profinet internal slave has already been configured.
Recommended actions
Remove I/O unit < arg > from the configuration.
6 Trouble shooting by Event log
341
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71444, Profinet diagnostics received
Description
The I/O unit < arg > has reported diagnostic data in slot arg .
arg
71445, Profinet PCI board error
Description
The Profinet PCI board could not be found.
Consequences
No connection to I/O units will be possible.
Probable causes
The Profinet PCI board is not installed or a 'reset to factory settings'
command has been performed. The 'reset to factory settings' command
demands another restart of the IRC5 controller in order to be
completed.
Recommended actions
1. Install the Profinet PCI board in the IRC5 controller.
2. Restart the IRC5 controller to perform the 'reset to factory settings'
command.
71446, Profinet configuration mismatch
Description
Configuration mismatch between the Fieldbus Adapter and the
connecting Profinet master in slot arg .
Consequences
The Fieldbus Adapter will indicate a diagnostic error and no
communication will be established between the Fieldbus Adapter and
the connecting Profinet master.
Probable causes
Mismatch of the data type/size in slot arg for the Profinet master
configuration. The expected data type/size is argarg bytes.
Recommended actions
Correct the data type/size in slot arg in the external configuration tool
or change the data size in the IRC5 controller configuration.
NOTE:
In the Profinet master configuration input data shall be in slot 1 and
output data in slot 2.
71447, Profinet internal slave error
Description
The I/O unit < arg > is configured as an internal slave. The unit address
must then be 0, but is configured to arg .
Consequences
The I/O unit < arg > will not be configured.
Recommended actions
Change the unit address to 0.
71448, I/O bus recovered from communication
failure
Description
The I/O bus < arg > has recover from the previous communication
failure.
71449, Too many fieldbus adapters configured
Description
Too many fieldbus adapters configured. It is only allowed to have one
fieldbus adapter configured.
Consequences
The fieldbus adapter < arg > has been rejected, and no functions
depending on it will work.
Recommended actions
1. Remove a fieldbus adapter in the configuration.
2. Restart the system.
71450, EtherNet/IP Master/Slave option not
installed
Description
A EtherNet/IP I/O bus is configured, but the EtherNet/IP Master/Slave
option has not been installed.
Consequences
No communication on the EtherNet/IP is possible. There may be
consequential errors from configuring EtherNet/IP when no such
option has been installed.
Probable causes
An attempt may have been made to add the EtherNet/IP functionality,
without installing the option correctly.
Recommended actions
1. If the EtherNet/IP option is required: configure a new system with
this option, and install the system.
2. If the EtherNet/IP option is not required: configure a new system
without this option, and install the system.
71451, Ethernet extra port option not installed
Description
A EtherNet/IP I/O bus is configured to use the extra Ethernet port, but
the Ethernet extra port option has not been installed.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
An attempt may have been made to add the EtherNet/IP functionality,
without installing the correct option.
6 Trouble shooting by Event log
342
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. If the Ethernet extra port option is required: configure a new system
with this option, and install the system.
2. If the Ethernet extra port option is not required: change the
configuration and restart the system.
71452, Too many EtherNet/IP buses are
configured
Description
Too many EtherNet/IP I/O buses are configured. There is only possibly
to have one I/O bus for EtherNet/IP Master/Slave.
Recommended actions
1. Remove one the EtherNet/IP buses from the configuration.
2. Restart the system.
71453, Wrong identity for a EtherNet/IP I/O unit
Description
Wrong identity for the I/O unit < arg >.
The correct identity is:
Vendor ID < arg >
Device Type < arg >
Product Code < arg >
Consequences
No contact will be established with this I/O unit.
Recommended actions
1. Correct the configuration for the I/O unit type < arg > with the
identity information above.
2. Restart the system.
71454, The arg address is missing
Description
No IP address is specified for the arg I/O bus.
Consequences
No communication on the arg I/O bus is possible.
Recommended actions
1. Specify a valid IP address in the I/O bus configuration.
2. Restart the system.
71455, EtherNet/IP connection type unknown
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown connection type < arg >.
The connection type must be one of the following:
- MULTICAST
- POINT2POINT
Consequences
This unit type has been rejected.
Recommended actions
1. Correct the connection type of the unit type.
2. Restart the system.
71456, EtherNet/IP hardware is missing
Description
The DSQC 612 hardware needed for running EtherNet/IP is missing.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
An attempt may have been made to add EtherNet/IP functionality on
the first Ethernet port, without installing the correct hardware.
Note: If you are running MultiMove two DSQC 612 boards are
required, otherwise one board.
Recommended actions
1. Install a DSQC 612 board in the IRC5 controller.
2. Restart the system.
71457, The EtherNet/IP gateway address is
invalid
Description
It is not possible to have the gateway address same as the IP address.
Or the gateway address can not be same as the default destination
<0.0.0.0>.
Consequences
The default IRC5 controller gateway address < arg > will be used and
not the specified gateway address < arg >.
Recommended actions
1. If no physical gateway is used, do not specify any gateway address
in the configuration.
2. Restart the system.
71458, Could not change the default gateway
address
Description
If no destination address is specified in the Ethernet/IP configuration,
the default IRC5 controller gateway address will be changed. The
destination address was not given and the specified gateway address
< arg > was not valid and could not be used..
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the gateway in the EtherNet/IP I/O bus configuration.
2. Restart the system.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 344
|
6 Trouble shooting by Event log
341
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71444, Profinet diagnostics received
Description
The I/O unit < arg > has reported diagnostic data in slot arg .
arg
71445, Profinet PCI board error
Description
The Profinet PCI board could not be found.
Consequences
No connection to I/O units will be possible.
Probable causes
The Profinet PCI board is not installed or a 'reset to factory settings'
command has been performed. The 'reset to factory settings' command
demands another restart of the IRC5 controller in order to be
completed.
Recommended actions
1. Install the Profinet PCI board in the IRC5 controller.
2. Restart the IRC5 controller to perform the 'reset to factory settings'
command.
71446, Profinet configuration mismatch
Description
Configuration mismatch between the Fieldbus Adapter and the
connecting Profinet master in slot arg .
Consequences
The Fieldbus Adapter will indicate a diagnostic error and no
communication will be established between the Fieldbus Adapter and
the connecting Profinet master.
Probable causes
Mismatch of the data type/size in slot arg for the Profinet master
configuration. The expected data type/size is argarg bytes.
Recommended actions
Correct the data type/size in slot arg in the external configuration tool
or change the data size in the IRC5 controller configuration.
NOTE:
In the Profinet master configuration input data shall be in slot 1 and
output data in slot 2.
71447, Profinet internal slave error
Description
The I/O unit < arg > is configured as an internal slave. The unit address
must then be 0, but is configured to arg .
Consequences
The I/O unit < arg > will not be configured.
Recommended actions
Change the unit address to 0.
71448, I/O bus recovered from communication
failure
Description
The I/O bus < arg > has recover from the previous communication
failure.
71449, Too many fieldbus adapters configured
Description
Too many fieldbus adapters configured. It is only allowed to have one
fieldbus adapter configured.
Consequences
The fieldbus adapter < arg > has been rejected, and no functions
depending on it will work.
Recommended actions
1. Remove a fieldbus adapter in the configuration.
2. Restart the system.
71450, EtherNet/IP Master/Slave option not
installed
Description
A EtherNet/IP I/O bus is configured, but the EtherNet/IP Master/Slave
option has not been installed.
Consequences
No communication on the EtherNet/IP is possible. There may be
consequential errors from configuring EtherNet/IP when no such
option has been installed.
Probable causes
An attempt may have been made to add the EtherNet/IP functionality,
without installing the option correctly.
Recommended actions
1. If the EtherNet/IP option is required: configure a new system with
this option, and install the system.
2. If the EtherNet/IP option is not required: configure a new system
without this option, and install the system.
71451, Ethernet extra port option not installed
Description
A EtherNet/IP I/O bus is configured to use the extra Ethernet port, but
the Ethernet extra port option has not been installed.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
An attempt may have been made to add the EtherNet/IP functionality,
without installing the correct option.
6 Trouble shooting by Event log
342
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. If the Ethernet extra port option is required: configure a new system
with this option, and install the system.
2. If the Ethernet extra port option is not required: change the
configuration and restart the system.
71452, Too many EtherNet/IP buses are
configured
Description
Too many EtherNet/IP I/O buses are configured. There is only possibly
to have one I/O bus for EtherNet/IP Master/Slave.
Recommended actions
1. Remove one the EtherNet/IP buses from the configuration.
2. Restart the system.
71453, Wrong identity for a EtherNet/IP I/O unit
Description
Wrong identity for the I/O unit < arg >.
The correct identity is:
Vendor ID < arg >
Device Type < arg >
Product Code < arg >
Consequences
No contact will be established with this I/O unit.
Recommended actions
1. Correct the configuration for the I/O unit type < arg > with the
identity information above.
2. Restart the system.
71454, The arg address is missing
Description
No IP address is specified for the arg I/O bus.
Consequences
No communication on the arg I/O bus is possible.
Recommended actions
1. Specify a valid IP address in the I/O bus configuration.
2. Restart the system.
71455, EtherNet/IP connection type unknown
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown connection type < arg >.
The connection type must be one of the following:
- MULTICAST
- POINT2POINT
Consequences
This unit type has been rejected.
Recommended actions
1. Correct the connection type of the unit type.
2. Restart the system.
71456, EtherNet/IP hardware is missing
Description
The DSQC 612 hardware needed for running EtherNet/IP is missing.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
An attempt may have been made to add EtherNet/IP functionality on
the first Ethernet port, without installing the correct hardware.
Note: If you are running MultiMove two DSQC 612 boards are
required, otherwise one board.
Recommended actions
1. Install a DSQC 612 board in the IRC5 controller.
2. Restart the system.
71457, The EtherNet/IP gateway address is
invalid
Description
It is not possible to have the gateway address same as the IP address.
Or the gateway address can not be same as the default destination
<0.0.0.0>.
Consequences
The default IRC5 controller gateway address < arg > will be used and
not the specified gateway address < arg >.
Recommended actions
1. If no physical gateway is used, do not specify any gateway address
in the configuration.
2. Restart the system.
71458, Could not change the default gateway
address
Description
If no destination address is specified in the Ethernet/IP configuration,
the default IRC5 controller gateway address will be changed. The
destination address was not given and the specified gateway address
< arg > was not valid and could not be used..
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the gateway in the EtherNet/IP I/O bus configuration.
2. Restart the system.
6 Trouble shooting by Event log
343
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71459, Illegal address for EtherNet/IP
Description
The address < arg > for the EtherNet/IP bus is illegal.
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the address in the EtherNet/IP bus configuration.
2. Restart the system.
71460, Not able to connect to EtherNet/IP I/O
unit
Description
The configured I/O unit < arg > with address < arg > does not physically
exist on the EtherNet/IP bus.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller. The system will go to
state SYS FAIL, if the I/O unit has been assigned Unit Trust level
Required (0) in the configuration.
Probable causes
The I/O unit does not exist physically.
The I/O unit address is wrong.
The I/O unit is malfunctioning.
Recommended actions
1. Check if the I/O unit physically exist on the EtherNet/IP bus or if the
address is correct.
2. If the address has been changed, restart the system.
71461, Duplicated address on the EtherNet/IP I/
O bus
Description
The I/O unit < arg > and the EtherNet/IP master have been configured
with the same address in the controller.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller.
Recommended actions
1. Change the address for the I/O unit < arg > or the address for the
EtherNet/IP master in the configuration. If changing the I/O unit
address and it have this address physically it must also be changed in
the I/O unit.
2. Restart the system.
71462, Illegal subnet mask for EtherNet/IP
Description
The subnet mask < arg > for the EtherNet/IP bus is illegal.
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the subnet mask in the EtherNet/IP bus configuration.
2. Restart the system.
71463, Illegal address for EtherNet/IP bus
Description
The EtherNet/IP address < arg > is reserved.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
The specified address is on a subnet reserved by another Ethernet port.
Two Ethernet ports on the IRC5 controller can not be on the same
subnet.
Example:
EtherNet/IP port: 192.168.125.x
Service port: 192.168.125.x
Note:
The subnets within the range 192.168.125.xxx - 192.168.130.xxx are
predefined and can not be used.
Recommended actions
1. Change the address to another subnet.
2. Restart the system.
71464, Could not add a new gateway for
EtherNet/IP
Description
Could not add the gateway address < arg > with the destination address
< arg > for EtherNet/IP.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
1. The gateway address or the destination address are invalid.
2. No destination address have been specified.
Recommended actions
1. Correct the gateway address or the destination address in the
EtherNet/IP bus configuration.
2. Restart the system.
71465, DeviceNet Lean error response
Description
The I/O unit < arg > has reported an error response.
General Error Code arg .
Additional Code arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 345
|
6 Trouble shooting by Event log
342
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. If the Ethernet extra port option is required: configure a new system
with this option, and install the system.
2. If the Ethernet extra port option is not required: change the
configuration and restart the system.
71452, Too many EtherNet/IP buses are
configured
Description
Too many EtherNet/IP I/O buses are configured. There is only possibly
to have one I/O bus for EtherNet/IP Master/Slave.
Recommended actions
1. Remove one the EtherNet/IP buses from the configuration.
2. Restart the system.
71453, Wrong identity for a EtherNet/IP I/O unit
Description
Wrong identity for the I/O unit < arg >.
The correct identity is:
Vendor ID < arg >
Device Type < arg >
Product Code < arg >
Consequences
No contact will be established with this I/O unit.
Recommended actions
1. Correct the configuration for the I/O unit type < arg > with the
identity information above.
2. Restart the system.
71454, The arg address is missing
Description
No IP address is specified for the arg I/O bus.
Consequences
No communication on the arg I/O bus is possible.
Recommended actions
1. Specify a valid IP address in the I/O bus configuration.
2. Restart the system.
71455, EtherNet/IP connection type unknown
Description
The I/O configuration is invalid.
The unit type < arg > has an invalid/unknown connection type < arg >.
The connection type must be one of the following:
- MULTICAST
- POINT2POINT
Consequences
This unit type has been rejected.
Recommended actions
1. Correct the connection type of the unit type.
2. Restart the system.
71456, EtherNet/IP hardware is missing
Description
The DSQC 612 hardware needed for running EtherNet/IP is missing.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
An attempt may have been made to add EtherNet/IP functionality on
the first Ethernet port, without installing the correct hardware.
Note: If you are running MultiMove two DSQC 612 boards are
required, otherwise one board.
Recommended actions
1. Install a DSQC 612 board in the IRC5 controller.
2. Restart the system.
71457, The EtherNet/IP gateway address is
invalid
Description
It is not possible to have the gateway address same as the IP address.
Or the gateway address can not be same as the default destination
<0.0.0.0>.
Consequences
The default IRC5 controller gateway address < arg > will be used and
not the specified gateway address < arg >.
Recommended actions
1. If no physical gateway is used, do not specify any gateway address
in the configuration.
2. Restart the system.
71458, Could not change the default gateway
address
Description
If no destination address is specified in the Ethernet/IP configuration,
the default IRC5 controller gateway address will be changed. The
destination address was not given and the specified gateway address
< arg > was not valid and could not be used..
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the gateway in the EtherNet/IP I/O bus configuration.
2. Restart the system.
6 Trouble shooting by Event log
343
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71459, Illegal address for EtherNet/IP
Description
The address < arg > for the EtherNet/IP bus is illegal.
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the address in the EtherNet/IP bus configuration.
2. Restart the system.
71460, Not able to connect to EtherNet/IP I/O
unit
Description
The configured I/O unit < arg > with address < arg > does not physically
exist on the EtherNet/IP bus.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller. The system will go to
state SYS FAIL, if the I/O unit has been assigned Unit Trust level
Required (0) in the configuration.
Probable causes
The I/O unit does not exist physically.
The I/O unit address is wrong.
The I/O unit is malfunctioning.
Recommended actions
1. Check if the I/O unit physically exist on the EtherNet/IP bus or if the
address is correct.
2. If the address has been changed, restart the system.
71461, Duplicated address on the EtherNet/IP I/
O bus
Description
The I/O unit < arg > and the EtherNet/IP master have been configured
with the same address in the controller.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller.
Recommended actions
1. Change the address for the I/O unit < arg > or the address for the
EtherNet/IP master in the configuration. If changing the I/O unit
address and it have this address physically it must also be changed in
the I/O unit.
2. Restart the system.
71462, Illegal subnet mask for EtherNet/IP
Description
The subnet mask < arg > for the EtherNet/IP bus is illegal.
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the subnet mask in the EtherNet/IP bus configuration.
2. Restart the system.
71463, Illegal address for EtherNet/IP bus
Description
The EtherNet/IP address < arg > is reserved.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
The specified address is on a subnet reserved by another Ethernet port.
Two Ethernet ports on the IRC5 controller can not be on the same
subnet.
Example:
EtherNet/IP port: 192.168.125.x
Service port: 192.168.125.x
Note:
The subnets within the range 192.168.125.xxx - 192.168.130.xxx are
predefined and can not be used.
Recommended actions
1. Change the address to another subnet.
2. Restart the system.
71464, Could not add a new gateway for
EtherNet/IP
Description
Could not add the gateway address < arg > with the destination address
< arg > for EtherNet/IP.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
1. The gateway address or the destination address are invalid.
2. No destination address have been specified.
Recommended actions
1. Correct the gateway address or the destination address in the
EtherNet/IP bus configuration.
2. Restart the system.
71465, DeviceNet Lean error response
Description
The I/O unit < arg > has reported an error response.
General Error Code arg .
Additional Code arg
6 Trouble shooting by Event log
344
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Read about the General Error Code in the DeviceNet specification
Appendix H.
2. The I/O unit might be occupied by another master.
3. Cycle the power of the I/O unit.
71466, Profinet configuration failed
Description
The configuration file < arg > was not accepted by the DSQC 678.
Error code returned arg .
Consequences
No new configuration will be stored in the DSQC 678.
Recommended actions
Make sure that the correct filetype is used.
71467, Profinet configuration file missing
Description
The configuration file < arg > was not found.
Consequences
No new configuration will be stored in the DSQC 678.
Recommended actions
1. Make sure the file exists.
2. Make sure that the configuration file is placed in the HOME
directory of your current system.
71468, Profinet board DSQC 678 upgraded
Description
The Profinet board DSQC 678 have been upgraded to a new firmware
with version < arg >
Consequences
The new firmware might affect some of the configuration parameters
or other communication behaviour.
Recommended actions
1. Make sure that no configuration changes are needed for connecting
controllers.
2. Make sure that current Step 7 configuration in the DSQC 678 is
compatible with the new firmware.
71469, Max number of internal I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of internal I/O signals in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O signals specfied in the additional option configuration) so that the
maximum limit is not exceeded.
71470, Wrong unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not of the
same type as configured.
Reported vendor ID was arg , expected was arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
Change the I/O unit configuration.
71471, Duplicated address on DeviceNet Lean
bus
Description
The I/O unit < arg > and the DeviceNet Lean master is configured with
the same address.
Consequences
The I/O unit < arg > has been rejected.
Recommended actions
1. Change address for I/O unit < arg > or the DeviceNet Lean master.
71472, Fieldbus command error
Description
Could not send fieldbus command to I/O unit < arg > because there is a
syntax error in the command path string.
Fieldbus command type name < arg >.
Additional info:
arg
Consequences
The fieldbus command was not sent.
Recommended actions
1. Correct the fieldbus command path string.
71473, DeviceNet Lean bus scan result
Description
Address: Product: Vendor ID: Product code:
arg
80001, arg
Description
arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 346
|
6 Trouble shooting by Event log
343
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
71459, Illegal address for EtherNet/IP
Description
The address < arg > for the EtherNet/IP bus is illegal.
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the address in the EtherNet/IP bus configuration.
2. Restart the system.
71460, Not able to connect to EtherNet/IP I/O
unit
Description
The configured I/O unit < arg > with address < arg > does not physically
exist on the EtherNet/IP bus.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller. The system will go to
state SYS FAIL, if the I/O unit has been assigned Unit Trust level
Required (0) in the configuration.
Probable causes
The I/O unit does not exist physically.
The I/O unit address is wrong.
The I/O unit is malfunctioning.
Recommended actions
1. Check if the I/O unit physically exist on the EtherNet/IP bus or if the
address is correct.
2. If the address has been changed, restart the system.
71461, Duplicated address on the EtherNet/IP I/
O bus
Description
The I/O unit < arg > and the EtherNet/IP master have been configured
with the same address in the controller.
Consequences
It is not possible to access the I/O unit or I/O signals on it, since it is
currently not communicating with the controller.
Recommended actions
1. Change the address for the I/O unit < arg > or the address for the
EtherNet/IP master in the configuration. If changing the I/O unit
address and it have this address physically it must also be changed in
the I/O unit.
2. Restart the system.
71462, Illegal subnet mask for EtherNet/IP
Description
The subnet mask < arg > for the EtherNet/IP bus is illegal.
Consequences
No communication on the EtherNet/IP bus is possible.
Recommended actions
1. Correct the subnet mask in the EtherNet/IP bus configuration.
2. Restart the system.
71463, Illegal address for EtherNet/IP bus
Description
The EtherNet/IP address < arg > is reserved.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
The specified address is on a subnet reserved by another Ethernet port.
Two Ethernet ports on the IRC5 controller can not be on the same
subnet.
Example:
EtherNet/IP port: 192.168.125.x
Service port: 192.168.125.x
Note:
The subnets within the range 192.168.125.xxx - 192.168.130.xxx are
predefined and can not be used.
Recommended actions
1. Change the address to another subnet.
2. Restart the system.
71464, Could not add a new gateway for
EtherNet/IP
Description
Could not add the gateway address < arg > with the destination address
< arg > for EtherNet/IP.
Consequences
No communication on the EtherNet/IP bus is possible.
Probable causes
1. The gateway address or the destination address are invalid.
2. No destination address have been specified.
Recommended actions
1. Correct the gateway address or the destination address in the
EtherNet/IP bus configuration.
2. Restart the system.
71465, DeviceNet Lean error response
Description
The I/O unit < arg > has reported an error response.
General Error Code arg .
Additional Code arg
6 Trouble shooting by Event log
344
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Read about the General Error Code in the DeviceNet specification
Appendix H.
2. The I/O unit might be occupied by another master.
3. Cycle the power of the I/O unit.
71466, Profinet configuration failed
Description
The configuration file < arg > was not accepted by the DSQC 678.
Error code returned arg .
Consequences
No new configuration will be stored in the DSQC 678.
Recommended actions
Make sure that the correct filetype is used.
71467, Profinet configuration file missing
Description
The configuration file < arg > was not found.
Consequences
No new configuration will be stored in the DSQC 678.
Recommended actions
1. Make sure the file exists.
2. Make sure that the configuration file is placed in the HOME
directory of your current system.
71468, Profinet board DSQC 678 upgraded
Description
The Profinet board DSQC 678 have been upgraded to a new firmware
with version < arg >
Consequences
The new firmware might affect some of the configuration parameters
or other communication behaviour.
Recommended actions
1. Make sure that no configuration changes are needed for connecting
controllers.
2. Make sure that current Step 7 configuration in the DSQC 678 is
compatible with the new firmware.
71469, Max number of internal I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of internal I/O signals in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O signals specfied in the additional option configuration) so that the
maximum limit is not exceeded.
71470, Wrong unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not of the
same type as configured.
Reported vendor ID was arg , expected was arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
Change the I/O unit configuration.
71471, Duplicated address on DeviceNet Lean
bus
Description
The I/O unit < arg > and the DeviceNet Lean master is configured with
the same address.
Consequences
The I/O unit < arg > has been rejected.
Recommended actions
1. Change address for I/O unit < arg > or the DeviceNet Lean master.
71472, Fieldbus command error
Description
Could not send fieldbus command to I/O unit < arg > because there is a
syntax error in the command path string.
Fieldbus command type name < arg >.
Additional info:
arg
Consequences
The fieldbus command was not sent.
Recommended actions
1. Correct the fieldbus command path string.
71473, DeviceNet Lean bus scan result
Description
Address: Product: Vendor ID: Product code:
arg
80001, arg
Description
arg
6 Trouble shooting by Event log
345
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
arg
arg
arg
Recommended actions
80002, arg
Description
arg
arg
arg
arg
Recommended actions
80003, arg
Description
arg
arg
arg
arg
Recommended actions
9,
Description
10,
Description
110001, Process Supervision Phase PRE
Description
Task: arg
Supervision failed for process phase PRE.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110002, Process Supervision Phase
PRE_START
Description
Task: arg
Supervision failed for process phase PRE_START.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110003, Process Supervision Phase START
Description
Task: arg
Supervision failed for process phase START.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110004, Process Supervision Phase MAIN
Description
Task: arg
Supervision failed for process phase MAIN.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110005, Process Supervision Phase END_MAIN
Description
Task: arg
Supervision failed for process phase END_MAIN.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 347
|
6 Trouble shooting by Event log
344
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Read about the General Error Code in the DeviceNet specification
Appendix H.
2. The I/O unit might be occupied by another master.
3. Cycle the power of the I/O unit.
71466, Profinet configuration failed
Description
The configuration file < arg > was not accepted by the DSQC 678.
Error code returned arg .
Consequences
No new configuration will be stored in the DSQC 678.
Recommended actions
Make sure that the correct filetype is used.
71467, Profinet configuration file missing
Description
The configuration file < arg > was not found.
Consequences
No new configuration will be stored in the DSQC 678.
Recommended actions
1. Make sure the file exists.
2. Make sure that the configuration file is placed in the HOME
directory of your current system.
71468, Profinet board DSQC 678 upgraded
Description
The Profinet board DSQC 678 have been upgraded to a new firmware
with version < arg >
Consequences
The new firmware might affect some of the configuration parameters
or other communication behaviour.
Recommended actions
1. Make sure that no configuration changes are needed for connecting
controllers.
2. Make sure that current Step 7 configuration in the DSQC 678 is
compatible with the new firmware.
71469, Max number of internal I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg , of internal I/O signals in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the number of
I/O signals specfied in the additional option configuration) so that the
maximum limit is not exceeded.
71470, Wrong unit type
Description
The I/O unit < arg > connected to the DeviceNet Lean bus is not of the
same type as configured.
Reported vendor ID was arg , expected was arg .
Consequences
No communication to the I/O unit is possible.
Recommended actions
Change the I/O unit configuration.
71471, Duplicated address on DeviceNet Lean
bus
Description
The I/O unit < arg > and the DeviceNet Lean master is configured with
the same address.
Consequences
The I/O unit < arg > has been rejected.
Recommended actions
1. Change address for I/O unit < arg > or the DeviceNet Lean master.
71472, Fieldbus command error
Description
Could not send fieldbus command to I/O unit < arg > because there is a
syntax error in the command path string.
Fieldbus command type name < arg >.
Additional info:
arg
Consequences
The fieldbus command was not sent.
Recommended actions
1. Correct the fieldbus command path string.
71473, DeviceNet Lean bus scan result
Description
Address: Product: Vendor ID: Product code:
arg
80001, arg
Description
arg
6 Trouble shooting by Event log
345
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
arg
arg
arg
Recommended actions
80002, arg
Description
arg
arg
arg
arg
Recommended actions
80003, arg
Description
arg
arg
arg
arg
Recommended actions
9,
Description
10,
Description
110001, Process Supervision Phase PRE
Description
Task: arg
Supervision failed for process phase PRE.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110002, Process Supervision Phase
PRE_START
Description
Task: arg
Supervision failed for process phase PRE_START.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110003, Process Supervision Phase START
Description
Task: arg
Supervision failed for process phase START.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110004, Process Supervision Phase MAIN
Description
Task: arg
Supervision failed for process phase MAIN.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110005, Process Supervision Phase END_MAIN
Description
Task: arg
Supervision failed for process phase END_MAIN.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
6 Trouble shooting by Event log
346
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110006, Process Supervision Phase POST1
Description
Task: arg
Supervision failed for process phase POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110007, Process Supervision Phase
END_POST1
Description
Task: arg
Supervision failed for process phase END_POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110008, Process Supervision Phase POST2
Description
Task: arg
Supervision failed for process phase POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110009, Process Supervision Phase
END_POST2
Description
Task: arg
Supervision failed for process phase END_POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110012, Movement start timeout
Description
Task: arg
Time ( arg second(s)) between start of process and Robot movement is
too long.
Recommended actions
Check your process equipment.
110013, Application process interrupted
Description
Task: arg
The application process was not terminated properly.
arg
Consequences
Eventual post-motion phases were not executed.
Probable causes
1. Logical RAPID instructions in a sequence of application movement
instructions consuming too much execution time.
2. The last instruction in the sequence of application movement
instructions, that does not indicate the sequence end.
3. A process error occurred too close to the endpoint of the process: a
process restart is not performed.
Recommended actions
Remove the logical instructions, that cause the delay,
or
check, that the last application movement instruction indicates, that it
is the last one.
110014, Option 'Optical Tracking' or 'Weldguide'
is missing
Description
Task: arg
The optional argument '\Track' may not be used without the option
'Optical Tracking' or 'Weldguide'.
arg
Recommended actions
Remove the optional argument '\Track'
or
Order a RobotWare key that, depending on your equipment, contains
the option 'Optical Tracking' or 'Weldguide'.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 348
|
6 Trouble shooting by Event log
345
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
arg
arg
arg
Recommended actions
80002, arg
Description
arg
arg
arg
arg
Recommended actions
80003, arg
Description
arg
arg
arg
arg
Recommended actions
9,
Description
10,
Description
110001, Process Supervision Phase PRE
Description
Task: arg
Supervision failed for process phase PRE.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110002, Process Supervision Phase
PRE_START
Description
Task: arg
Supervision failed for process phase PRE_START.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110003, Process Supervision Phase START
Description
Task: arg
Supervision failed for process phase START.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110004, Process Supervision Phase MAIN
Description
Task: arg
Supervision failed for process phase MAIN.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110005, Process Supervision Phase END_MAIN
Description
Task: arg
Supervision failed for process phase END_MAIN.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
6 Trouble shooting by Event log
346
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110006, Process Supervision Phase POST1
Description
Task: arg
Supervision failed for process phase POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110007, Process Supervision Phase
END_POST1
Description
Task: arg
Supervision failed for process phase END_POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110008, Process Supervision Phase POST2
Description
Task: arg
Supervision failed for process phase POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110009, Process Supervision Phase
END_POST2
Description
Task: arg
Supervision failed for process phase END_POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110012, Movement start timeout
Description
Task: arg
Time ( arg second(s)) between start of process and Robot movement is
too long.
Recommended actions
Check your process equipment.
110013, Application process interrupted
Description
Task: arg
The application process was not terminated properly.
arg
Consequences
Eventual post-motion phases were not executed.
Probable causes
1. Logical RAPID instructions in a sequence of application movement
instructions consuming too much execution time.
2. The last instruction in the sequence of application movement
instructions, that does not indicate the sequence end.
3. A process error occurred too close to the endpoint of the process: a
process restart is not performed.
Recommended actions
Remove the logical instructions, that cause the delay,
or
check, that the last application movement instruction indicates, that it
is the last one.
110014, Option 'Optical Tracking' or 'Weldguide'
is missing
Description
Task: arg
The optional argument '\Track' may not be used without the option
'Optical Tracking' or 'Weldguide'.
arg
Recommended actions
Remove the optional argument '\Track'
or
Order a RobotWare key that, depending on your equipment, contains
the option 'Optical Tracking' or 'Weldguide'.
6 Trouble shooting by Event log
347
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110015, Option Path Offset is missing
Description
Task: arg
The switch '\Corr' may not be used without the option Path Offset.
arg
Recommended actions
Remove the switch '\Corr'
or
Order a RobotWare key, that contains the option 'Path Offset'.
110016, Unsafe flying end
Description
Program execution has proceeded to the next RAPID instruction
before the application process finished.
Consequences
If a process error occurs, the application process will be stopped on the
fly, but the robot movement will not be stopped.
Probable causes
The zone size and the fly_end distance of the flying end instruction do
not fit together.
Recommended actions
Increase fly_end distance or decrease the zone size of the instruction
with flying end.
110020, Supervision limit
Description
Task: arg
The maximum number of signals to be supervised (max. 32) has been
exceeded in one of the supervision phases.
arg
Recommended actions
Remove signals from supervision for phase arg in order to meet the
limit of 32.
110021, Unknown supervision list
Description
Task: arg
The Supervision list type arg is unknown.
arg
Consequences
Supervision is not set up or removed.
Recommended actions
Change the supervision list type.
110025, No active CAP process
Description
Task: arg
There is no active CAP process for this instruction.
arg
Recommended actions
Verify that arg is used according to documentation.
110030, Invalid ICap Event
Description
Task: arg
arg is invalid as event for the instruction ICap.
arg
Recommended actions
Use one of the valid ICap events described in the reference manual for
CAP.
110032, No TRAP routine for CAP_STOP
Description
Task: arg
CAP requires a RAPID TRAP routine to be defined for the event
CAP_STOP.
This is necessary as to stop external equipment when RAPID
execution stops.
arg
Recommended actions
Add a TRAP routine for CAP_STOP in your RAPID code.
110034, Skip without process finished
Description
The robot has reached the end of the distance it was requested to move
without active application process.
Recommended actions
Recovery:
You might want to handle errno arg in your error handler
110040, Process Supervision Phase END_PRE
Description
Task: arg
Supervision failed for process phase END_PRE.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 349
|
6 Trouble shooting by Event log
346
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110006, Process Supervision Phase POST1
Description
Task: arg
Supervision failed for process phase POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110007, Process Supervision Phase
END_POST1
Description
Task: arg
Supervision failed for process phase END_POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110008, Process Supervision Phase POST2
Description
Task: arg
Supervision failed for process phase POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110009, Process Supervision Phase
END_POST2
Description
Task: arg
Supervision failed for process phase END_POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110012, Movement start timeout
Description
Task: arg
Time ( arg second(s)) between start of process and Robot movement is
too long.
Recommended actions
Check your process equipment.
110013, Application process interrupted
Description
Task: arg
The application process was not terminated properly.
arg
Consequences
Eventual post-motion phases were not executed.
Probable causes
1. Logical RAPID instructions in a sequence of application movement
instructions consuming too much execution time.
2. The last instruction in the sequence of application movement
instructions, that does not indicate the sequence end.
3. A process error occurred too close to the endpoint of the process: a
process restart is not performed.
Recommended actions
Remove the logical instructions, that cause the delay,
or
check, that the last application movement instruction indicates, that it
is the last one.
110014, Option 'Optical Tracking' or 'Weldguide'
is missing
Description
Task: arg
The optional argument '\Track' may not be used without the option
'Optical Tracking' or 'Weldguide'.
arg
Recommended actions
Remove the optional argument '\Track'
or
Order a RobotWare key that, depending on your equipment, contains
the option 'Optical Tracking' or 'Weldguide'.
6 Trouble shooting by Event log
347
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110015, Option Path Offset is missing
Description
Task: arg
The switch '\Corr' may not be used without the option Path Offset.
arg
Recommended actions
Remove the switch '\Corr'
or
Order a RobotWare key, that contains the option 'Path Offset'.
110016, Unsafe flying end
Description
Program execution has proceeded to the next RAPID instruction
before the application process finished.
Consequences
If a process error occurs, the application process will be stopped on the
fly, but the robot movement will not be stopped.
Probable causes
The zone size and the fly_end distance of the flying end instruction do
not fit together.
Recommended actions
Increase fly_end distance or decrease the zone size of the instruction
with flying end.
110020, Supervision limit
Description
Task: arg
The maximum number of signals to be supervised (max. 32) has been
exceeded in one of the supervision phases.
arg
Recommended actions
Remove signals from supervision for phase arg in order to meet the
limit of 32.
110021, Unknown supervision list
Description
Task: arg
The Supervision list type arg is unknown.
arg
Consequences
Supervision is not set up or removed.
Recommended actions
Change the supervision list type.
110025, No active CAP process
Description
Task: arg
There is no active CAP process for this instruction.
arg
Recommended actions
Verify that arg is used according to documentation.
110030, Invalid ICap Event
Description
Task: arg
arg is invalid as event for the instruction ICap.
arg
Recommended actions
Use one of the valid ICap events described in the reference manual for
CAP.
110032, No TRAP routine for CAP_STOP
Description
Task: arg
CAP requires a RAPID TRAP routine to be defined for the event
CAP_STOP.
This is necessary as to stop external equipment when RAPID
execution stops.
arg
Recommended actions
Add a TRAP routine for CAP_STOP in your RAPID code.
110034, Skip without process finished
Description
The robot has reached the end of the distance it was requested to move
without active application process.
Recommended actions
Recovery:
You might want to handle errno arg in your error handler
110040, Process Supervision Phase END_PRE
Description
Task: arg
Supervision failed for process phase END_PRE.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
6 Trouble shooting by Event log
348
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recovery:
You might want to handle errno arg in your error handler
110041, Process Supervision Phase
START_POST1
Description
Task: arg
Supervision failed for process phase START_POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110042, Process Supervision Phase
START_POST2
Description
Task: arg
Supervision failed for process phase START_POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110100, Fatal process error
Description
Task: arg
A fatal process error has been reported. Check previous error messages
for more information about the reason of the error.
Recommended actions
A restart of the system or move of program pointer is highly
recommended.
110101, Invalid weave shape
Description
Task: arg
The weave shape used is invalid:
[No shape = 0, Zig-zag shape = 1, V-shape = 2, Triangular shape = 3]
Recommended actions
Correct the shape component.
110102, Invalid weave length
Description
Task: arg
The weave length used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component length.
110103, Invalid weave cycle time
Description
Task: arg
The weave cycle time used is invalid:
(0 - 100) [s]
Recommended actions
Correct the component cycle_time.
110104, Invalid weave width
Description
Task: arg
The weave width used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component width.
110105, Invalid weave height
Description
Task: arg
The weave height used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component height
110106, Invalid weave dwell left
Description
Task: arg
The weave dwell_left used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_left
110107, Invalid weave dwell center
Description
Task: arg
The weave dwell_center used is invalid:
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 350
|
6 Trouble shooting by Event log
347
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110015, Option Path Offset is missing
Description
Task: arg
The switch '\Corr' may not be used without the option Path Offset.
arg
Recommended actions
Remove the switch '\Corr'
or
Order a RobotWare key, that contains the option 'Path Offset'.
110016, Unsafe flying end
Description
Program execution has proceeded to the next RAPID instruction
before the application process finished.
Consequences
If a process error occurs, the application process will be stopped on the
fly, but the robot movement will not be stopped.
Probable causes
The zone size and the fly_end distance of the flying end instruction do
not fit together.
Recommended actions
Increase fly_end distance or decrease the zone size of the instruction
with flying end.
110020, Supervision limit
Description
Task: arg
The maximum number of signals to be supervised (max. 32) has been
exceeded in one of the supervision phases.
arg
Recommended actions
Remove signals from supervision for phase arg in order to meet the
limit of 32.
110021, Unknown supervision list
Description
Task: arg
The Supervision list type arg is unknown.
arg
Consequences
Supervision is not set up or removed.
Recommended actions
Change the supervision list type.
110025, No active CAP process
Description
Task: arg
There is no active CAP process for this instruction.
arg
Recommended actions
Verify that arg is used according to documentation.
110030, Invalid ICap Event
Description
Task: arg
arg is invalid as event for the instruction ICap.
arg
Recommended actions
Use one of the valid ICap events described in the reference manual for
CAP.
110032, No TRAP routine for CAP_STOP
Description
Task: arg
CAP requires a RAPID TRAP routine to be defined for the event
CAP_STOP.
This is necessary as to stop external equipment when RAPID
execution stops.
arg
Recommended actions
Add a TRAP routine for CAP_STOP in your RAPID code.
110034, Skip without process finished
Description
The robot has reached the end of the distance it was requested to move
without active application process.
Recommended actions
Recovery:
You might want to handle errno arg in your error handler
110040, Process Supervision Phase END_PRE
Description
Task: arg
Supervision failed for process phase END_PRE.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
6 Trouble shooting by Event log
348
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recovery:
You might want to handle errno arg in your error handler
110041, Process Supervision Phase
START_POST1
Description
Task: arg
Supervision failed for process phase START_POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110042, Process Supervision Phase
START_POST2
Description
Task: arg
Supervision failed for process phase START_POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110100, Fatal process error
Description
Task: arg
A fatal process error has been reported. Check previous error messages
for more information about the reason of the error.
Recommended actions
A restart of the system or move of program pointer is highly
recommended.
110101, Invalid weave shape
Description
Task: arg
The weave shape used is invalid:
[No shape = 0, Zig-zag shape = 1, V-shape = 2, Triangular shape = 3]
Recommended actions
Correct the shape component.
110102, Invalid weave length
Description
Task: arg
The weave length used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component length.
110103, Invalid weave cycle time
Description
Task: arg
The weave cycle time used is invalid:
(0 - 100) [s]
Recommended actions
Correct the component cycle_time.
110104, Invalid weave width
Description
Task: arg
The weave width used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component width.
110105, Invalid weave height
Description
Task: arg
The weave height used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component height
110106, Invalid weave dwell left
Description
Task: arg
The weave dwell_left used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_left
110107, Invalid weave dwell center
Description
Task: arg
The weave dwell_center used is invalid:
6 Trouble shooting by Event log
349
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
(0 - 1) [m]
Recommended actions
Correct the component dwell_center
110108, Invalid weave dwell right
Description
Task: arg
The weave dwell_right used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_right
110109, Invalid weave bias
Description
Task: arg
The weave bias used is invalid:
(-1 - 1) [m]
Recommended actions
Correct the component bias
110110, Invalid weave direction angle
Description
Task: arg
The weave direction angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component dir
110111, Invalid weave tilt angle
Description
Task: arg
The weave tilt angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component tilt
110112, Invalid weave rotation angle
Description
Task: arg
The weave rotation angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component rot
110113, Invalid horizontal weave offset
Description
Task: arg
The horizontal weave offset is invalid:
110114, Invalid vertical weave offset
Description
Task: arg
The vertical weave offset is invalid:
110115, Invalid weave sync left
Description
Task: arg
The weave sync left value is invalid:
(0 - 100) [%]
Recommended actions
Correct the component ptrn_sync_left in capweavedata.
110116, Invalid weave sync right
Description
Task: arg
The weave sync right value is invalid:
(0 - 100) [%]
Recommended actions
Correct the component ptrn_sync_right in capweavedata.
110117, Weave bias not allowed
Description
Task: arg
It is not allowed to use bias for shapes other than Zig-zag (=1).
Recommended actions
Correct the components 'bias' and/or 'shape' in capweavedata.
110118, Weave bias too big
Description
Task: arg
It is not allowed to use a bias that is bigger than half the width.
Recommended actions
Correct the components 'bias' and/or 'width' in capweavedata.
110119, Weave dwell too big
Description
Task: arg
It is not allowed to use a dwell that is bigger than the length.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 351
|
6 Trouble shooting by Event log
348
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recovery:
You might want to handle errno arg in your error handler
110041, Process Supervision Phase
START_POST1
Description
Task: arg
Supervision failed for process phase START_POST1.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110042, Process Supervision Phase
START_POST2
Description
Task: arg
Supervision failed for process phase START_POST2.
arg
Recommended actions
Check the signal(s) that failed:
arg
arg
Recovery:
You might want to handle errno arg in your error handler
110100, Fatal process error
Description
Task: arg
A fatal process error has been reported. Check previous error messages
for more information about the reason of the error.
Recommended actions
A restart of the system or move of program pointer is highly
recommended.
110101, Invalid weave shape
Description
Task: arg
The weave shape used is invalid:
[No shape = 0, Zig-zag shape = 1, V-shape = 2, Triangular shape = 3]
Recommended actions
Correct the shape component.
110102, Invalid weave length
Description
Task: arg
The weave length used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component length.
110103, Invalid weave cycle time
Description
Task: arg
The weave cycle time used is invalid:
(0 - 100) [s]
Recommended actions
Correct the component cycle_time.
110104, Invalid weave width
Description
Task: arg
The weave width used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component width.
110105, Invalid weave height
Description
Task: arg
The weave height used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component height
110106, Invalid weave dwell left
Description
Task: arg
The weave dwell_left used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_left
110107, Invalid weave dwell center
Description
Task: arg
The weave dwell_center used is invalid:
6 Trouble shooting by Event log
349
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
(0 - 1) [m]
Recommended actions
Correct the component dwell_center
110108, Invalid weave dwell right
Description
Task: arg
The weave dwell_right used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_right
110109, Invalid weave bias
Description
Task: arg
The weave bias used is invalid:
(-1 - 1) [m]
Recommended actions
Correct the component bias
110110, Invalid weave direction angle
Description
Task: arg
The weave direction angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component dir
110111, Invalid weave tilt angle
Description
Task: arg
The weave tilt angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component tilt
110112, Invalid weave rotation angle
Description
Task: arg
The weave rotation angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component rot
110113, Invalid horizontal weave offset
Description
Task: arg
The horizontal weave offset is invalid:
110114, Invalid vertical weave offset
Description
Task: arg
The vertical weave offset is invalid:
110115, Invalid weave sync left
Description
Task: arg
The weave sync left value is invalid:
(0 - 100) [%]
Recommended actions
Correct the component ptrn_sync_left in capweavedata.
110116, Invalid weave sync right
Description
Task: arg
The weave sync right value is invalid:
(0 - 100) [%]
Recommended actions
Correct the component ptrn_sync_right in capweavedata.
110117, Weave bias not allowed
Description
Task: arg
It is not allowed to use bias for shapes other than Zig-zag (=1).
Recommended actions
Correct the components 'bias' and/or 'shape' in capweavedata.
110118, Weave bias too big
Description
Task: arg
It is not allowed to use a bias that is bigger than half the width.
Recommended actions
Correct the components 'bias' and/or 'width' in capweavedata.
110119, Weave dwell too big
Description
Task: arg
It is not allowed to use a dwell that is bigger than the length.
6 Trouble shooting by Event log
350
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The ramp slope (amplitude/length) is limited.
Recommended actions
Correct the components 'dwell_right/center/left' and/or 'length' in
capweavedata.
110120, Weave bias change too big
Description
Task: arg
The weave bias change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for bias, and/or check that the change
of the bias is less than the maximum.
110121, Weave width tuning error
Description
Task: arg
The weave width change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for width, and/or check that the change
of the width is less than the maximum.
110122, Weave height tuning error
Description
Task: arg
The weave height change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave height tuning increment, and/or check that the change of
the height is less than the maximum.
110130, Signal not defined
Description
Task: arg
The signal arg is not defined.
arg
Recommended actions
Define the signal arg in eio.cfg
110131, No Signal specified
Description
Task: arg
No signal specified!
arg
Recommended actions
Specify a DI signal
110132, An internal error occurred
Description
Task: arg
arg
Recommended actions
Check the 'Internal' Log.
110160, Track error
Description
Task: arg
Track error.
arg
Recommended actions
Check joint definition.
Recovery: arg
110161, Track start error
Description
Task: arg
Track start error.
arg
Recommended actions
Check joint definition in captrackdata.
Recovery: arg
110162, Track max path corr error
Description
Task: arg
Track max path corr error.
arg
Recommended actions
Check joint definition and max_corr in captrackdata.
Recovery: arg
110163, Track communication error
Description
Task: arg
No communication between sensor and controller.
Recommended actions
Check the hardware
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 352
|
6 Trouble shooting by Event log
349
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
(0 - 1) [m]
Recommended actions
Correct the component dwell_center
110108, Invalid weave dwell right
Description
Task: arg
The weave dwell_right used is invalid:
(0 - 1) [m]
Recommended actions
Correct the component dwell_right
110109, Invalid weave bias
Description
Task: arg
The weave bias used is invalid:
(-1 - 1) [m]
Recommended actions
Correct the component bias
110110, Invalid weave direction angle
Description
Task: arg
The weave direction angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component dir
110111, Invalid weave tilt angle
Description
Task: arg
The weave tilt angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component tilt
110112, Invalid weave rotation angle
Description
Task: arg
The weave rotation angle used is invalid:
(-PI/2 - PI/2) [rad]
Recommended actions
Correct the component rot
110113, Invalid horizontal weave offset
Description
Task: arg
The horizontal weave offset is invalid:
110114, Invalid vertical weave offset
Description
Task: arg
The vertical weave offset is invalid:
110115, Invalid weave sync left
Description
Task: arg
The weave sync left value is invalid:
(0 - 100) [%]
Recommended actions
Correct the component ptrn_sync_left in capweavedata.
110116, Invalid weave sync right
Description
Task: arg
The weave sync right value is invalid:
(0 - 100) [%]
Recommended actions
Correct the component ptrn_sync_right in capweavedata.
110117, Weave bias not allowed
Description
Task: arg
It is not allowed to use bias for shapes other than Zig-zag (=1).
Recommended actions
Correct the components 'bias' and/or 'shape' in capweavedata.
110118, Weave bias too big
Description
Task: arg
It is not allowed to use a bias that is bigger than half the width.
Recommended actions
Correct the components 'bias' and/or 'width' in capweavedata.
110119, Weave dwell too big
Description
Task: arg
It is not allowed to use a dwell that is bigger than the length.
6 Trouble shooting by Event log
350
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The ramp slope (amplitude/length) is limited.
Recommended actions
Correct the components 'dwell_right/center/left' and/or 'length' in
capweavedata.
110120, Weave bias change too big
Description
Task: arg
The weave bias change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for bias, and/or check that the change
of the bias is less than the maximum.
110121, Weave width tuning error
Description
Task: arg
The weave width change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for width, and/or check that the change
of the width is less than the maximum.
110122, Weave height tuning error
Description
Task: arg
The weave height change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave height tuning increment, and/or check that the change of
the height is less than the maximum.
110130, Signal not defined
Description
Task: arg
The signal arg is not defined.
arg
Recommended actions
Define the signal arg in eio.cfg
110131, No Signal specified
Description
Task: arg
No signal specified!
arg
Recommended actions
Specify a DI signal
110132, An internal error occurred
Description
Task: arg
arg
Recommended actions
Check the 'Internal' Log.
110160, Track error
Description
Task: arg
Track error.
arg
Recommended actions
Check joint definition.
Recovery: arg
110161, Track start error
Description
Task: arg
Track start error.
arg
Recommended actions
Check joint definition in captrackdata.
Recovery: arg
110162, Track max path corr error
Description
Task: arg
Track max path corr error.
arg
Recommended actions
Check joint definition and max_corr in captrackdata.
Recovery: arg
110163, Track communication error
Description
Task: arg
No communication between sensor and controller.
Recommended actions
Check the hardware
6 Trouble shooting by Event log
351
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110164, Track correction lost
Description
Task: arg
Track lost due to power fail.
arg
Recommended actions
Move PP to main, or step through the rest of the CAP sequence.
110165, No Sensor Measurement
Description
Task: arg
No sensor measurement available.
arg
110166, Sensor Not ready yet
Description
Task: arg
The sensor is not ready.
arg
110167, General error from sensor
Description
Task: arg
General sensor error.
arg
110168, Sensor busy
Description
Task: arg
The sensor is busy.
arg
110169, Unknown command to sensor
Description
Task: arg
Some for the sensor unknown command was sent.
arg
110170, Illegal variable or block number in
sensor
Description
Task: arg
The variable number or block number is unknown to the sensor.
arg
110171, External alarm from sensor
Description
Task: arg
An external sensor alarm occurred.
arg
110172, Camera alarm from sensor
Description
Task: arg
The sensor camera sent an alarm.
arg
110173, Temperature alarm from sensor
Description
Task: arg
The sensor temperature is out of admitted bounds.
arg
110174, Value to sensor out of range
Description
Task: arg
The value sent to the sensor is out of bounds.
arg
110175, Camera check failed
Description
Task: arg
It was not possible to perform a sensor camera check.
arg
110176, Sensor communication time out
Description
Task: arg
Timeout occured in communication with the sensor.
arg
110177, Tracker calibration error
Description
Task: arg
Sensor: arg
It was not possible to perform a valid tracker calibration.
Consequences
The sensor arg is not calibrated, thus should not be used for tracking.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 353
|
6 Trouble shooting by Event log
350
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The ramp slope (amplitude/length) is limited.
Recommended actions
Correct the components 'dwell_right/center/left' and/or 'length' in
capweavedata.
110120, Weave bias change too big
Description
Task: arg
The weave bias change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for bias, and/or check that the change
of the bias is less than the maximum.
110121, Weave width tuning error
Description
Task: arg
The weave width change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for width, and/or check that the change
of the width is less than the maximum.
110122, Weave height tuning error
Description
Task: arg
The weave height change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave height tuning increment, and/or check that the change of
the height is less than the maximum.
110130, Signal not defined
Description
Task: arg
The signal arg is not defined.
arg
Recommended actions
Define the signal arg in eio.cfg
110131, No Signal specified
Description
Task: arg
No signal specified!
arg
Recommended actions
Specify a DI signal
110132, An internal error occurred
Description
Task: arg
arg
Recommended actions
Check the 'Internal' Log.
110160, Track error
Description
Task: arg
Track error.
arg
Recommended actions
Check joint definition.
Recovery: arg
110161, Track start error
Description
Task: arg
Track start error.
arg
Recommended actions
Check joint definition in captrackdata.
Recovery: arg
110162, Track max path corr error
Description
Task: arg
Track max path corr error.
arg
Recommended actions
Check joint definition and max_corr in captrackdata.
Recovery: arg
110163, Track communication error
Description
Task: arg
No communication between sensor and controller.
Recommended actions
Check the hardware
6 Trouble shooting by Event log
351
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110164, Track correction lost
Description
Task: arg
Track lost due to power fail.
arg
Recommended actions
Move PP to main, or step through the rest of the CAP sequence.
110165, No Sensor Measurement
Description
Task: arg
No sensor measurement available.
arg
110166, Sensor Not ready yet
Description
Task: arg
The sensor is not ready.
arg
110167, General error from sensor
Description
Task: arg
General sensor error.
arg
110168, Sensor busy
Description
Task: arg
The sensor is busy.
arg
110169, Unknown command to sensor
Description
Task: arg
Some for the sensor unknown command was sent.
arg
110170, Illegal variable or block number in
sensor
Description
Task: arg
The variable number or block number is unknown to the sensor.
arg
110171, External alarm from sensor
Description
Task: arg
An external sensor alarm occurred.
arg
110172, Camera alarm from sensor
Description
Task: arg
The sensor camera sent an alarm.
arg
110173, Temperature alarm from sensor
Description
Task: arg
The sensor temperature is out of admitted bounds.
arg
110174, Value to sensor out of range
Description
Task: arg
The value sent to the sensor is out of bounds.
arg
110175, Camera check failed
Description
Task: arg
It was not possible to perform a sensor camera check.
arg
110176, Sensor communication time out
Description
Task: arg
Timeout occured in communication with the sensor.
arg
110177, Tracker calibration error
Description
Task: arg
Sensor: arg
It was not possible to perform a valid tracker calibration.
Consequences
The sensor arg is not calibrated, thus should not be used for tracking.
6 Trouble shooting by Event log
352
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The average calibration precisions obtained in the x-, y-, z- directions
of the sensor tool are: arg . The desired ones are: arg .
Recommended actions
Verify that the calibration plate has not been moved. Check the sensor
settings. Start LTC to run a manual calibration setup followed by a new
calibration.
110178, Tracker verification error
Description
Task: arg
Sensor: arg
It was not possible to perform a valid tracker calibration verification.
Consequences
The sensor arg does not meet the calibration precision and will
therefore be unreliable for tracking.
Probable causes
The average verification precisions obtained in the x-, y-, z- directions
of the sensor tool are: arg . The desired ones are: arg .
Recommended actions
Start LTC to run a manual verification with a different number of
measurements. If problems persist, run a new manual calibration from
LTC.
110179, Left lap joint definition not correct
Description
Task: arg
Sensor: arg
The definition of the left joint (number arg ) is not correct.
Consequences
It will not be possible to perform a sensor calibration.
Probable causes
The measure obtained in the y-direction of the sensor tool on the left
lap-joint is : arg mm. The value should be positive.
Recommended actions
Check the left-lap joint definition ( arg ) in the sensor's ( arg )PC
interface. Possibly switch between the right and left lap-joint
definitions.
110180, Sensor Calibration Data updated
Description
The sensor calibration data for arg ( arg and arg ) are updated.
Task: arg
Recommended actions
If you use CAP without RW Arc, you have to rerun the RAPID
instruction
CapLATRSetup arg , arg , arg \SensorFreq:=xxx;
to make CAP use the updated sensor calibration data.
110203, Application error
Description
Task: arg
The maximum program number, 'DA_PROG_MAX' is above the num
data type limit.
Current value: arg
Consequences
The maximum configured program number will not be set.
Probable causes
The specified program number arg is above the maximum integer
value for the num data type, max value 8388608.
Recommended actions
Check the program.
110204, Application error
Description
Task: arg
Any return code other than DAOK is rejected from arg
Recommended actions
110205, Application error
Description
Task: arg
Forward sequence jumping is not allowed.
Recommended actions
Check the program sequence.
110206, Application error
Description
Task: arg
Missing I/O-signal arg .
Recommended actions
Check the I/O configuration.
110207, Application error
Description
Task: arg
Process number arg of application arg was already installed.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 354
|
6 Trouble shooting by Event log
351
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110164, Track correction lost
Description
Task: arg
Track lost due to power fail.
arg
Recommended actions
Move PP to main, or step through the rest of the CAP sequence.
110165, No Sensor Measurement
Description
Task: arg
No sensor measurement available.
arg
110166, Sensor Not ready yet
Description
Task: arg
The sensor is not ready.
arg
110167, General error from sensor
Description
Task: arg
General sensor error.
arg
110168, Sensor busy
Description
Task: arg
The sensor is busy.
arg
110169, Unknown command to sensor
Description
Task: arg
Some for the sensor unknown command was sent.
arg
110170, Illegal variable or block number in
sensor
Description
Task: arg
The variable number or block number is unknown to the sensor.
arg
110171, External alarm from sensor
Description
Task: arg
An external sensor alarm occurred.
arg
110172, Camera alarm from sensor
Description
Task: arg
The sensor camera sent an alarm.
arg
110173, Temperature alarm from sensor
Description
Task: arg
The sensor temperature is out of admitted bounds.
arg
110174, Value to sensor out of range
Description
Task: arg
The value sent to the sensor is out of bounds.
arg
110175, Camera check failed
Description
Task: arg
It was not possible to perform a sensor camera check.
arg
110176, Sensor communication time out
Description
Task: arg
Timeout occured in communication with the sensor.
arg
110177, Tracker calibration error
Description
Task: arg
Sensor: arg
It was not possible to perform a valid tracker calibration.
Consequences
The sensor arg is not calibrated, thus should not be used for tracking.
6 Trouble shooting by Event log
352
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The average calibration precisions obtained in the x-, y-, z- directions
of the sensor tool are: arg . The desired ones are: arg .
Recommended actions
Verify that the calibration plate has not been moved. Check the sensor
settings. Start LTC to run a manual calibration setup followed by a new
calibration.
110178, Tracker verification error
Description
Task: arg
Sensor: arg
It was not possible to perform a valid tracker calibration verification.
Consequences
The sensor arg does not meet the calibration precision and will
therefore be unreliable for tracking.
Probable causes
The average verification precisions obtained in the x-, y-, z- directions
of the sensor tool are: arg . The desired ones are: arg .
Recommended actions
Start LTC to run a manual verification with a different number of
measurements. If problems persist, run a new manual calibration from
LTC.
110179, Left lap joint definition not correct
Description
Task: arg
Sensor: arg
The definition of the left joint (number arg ) is not correct.
Consequences
It will not be possible to perform a sensor calibration.
Probable causes
The measure obtained in the y-direction of the sensor tool on the left
lap-joint is : arg mm. The value should be positive.
Recommended actions
Check the left-lap joint definition ( arg ) in the sensor's ( arg )PC
interface. Possibly switch between the right and left lap-joint
definitions.
110180, Sensor Calibration Data updated
Description
The sensor calibration data for arg ( arg and arg ) are updated.
Task: arg
Recommended actions
If you use CAP without RW Arc, you have to rerun the RAPID
instruction
CapLATRSetup arg , arg , arg \SensorFreq:=xxx;
to make CAP use the updated sensor calibration data.
110203, Application error
Description
Task: arg
The maximum program number, 'DA_PROG_MAX' is above the num
data type limit.
Current value: arg
Consequences
The maximum configured program number will not be set.
Probable causes
The specified program number arg is above the maximum integer
value for the num data type, max value 8388608.
Recommended actions
Check the program.
110204, Application error
Description
Task: arg
Any return code other than DAOK is rejected from arg
Recommended actions
110205, Application error
Description
Task: arg
Forward sequence jumping is not allowed.
Recommended actions
Check the program sequence.
110206, Application error
Description
Task: arg
Missing I/O-signal arg .
Recommended actions
Check the I/O configuration.
110207, Application error
Description
Task: arg
Process number arg of application arg was already installed.
6 Trouble shooting by Event log
353
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
110208, Application error
Description
Task: arg
Number arg is not a valid start number.
Recommended actions
110209, Application error
Description
Task: arg
The user hook arg is not a valid sequence entry.
Recommended actions
Check the program sequence.
110210, Application error
Description
Task: arg
The program number arg is above the num data type limit.
Consequences
The program number will not be set.
Probable causes
The specified program number arg is above the maximum integer
value for the num data type, max value 8388608.
Recommended actions
Check the program.
110211, Application error
Description
Task: arg
The instruction arg reported a fatal error.
Recommended actions
110212, Application error
Description
Task: arg
arg tried to use a non existent process descriptor.
A fatal error in damastr class.
arg
Probable causes
The XXShPowerOn has not been executed.
Recommended actions
Check if XXShPowerOn was done.
110214, Application error
Description
Task: arg
arg tried to use a non existent application descriptor.
arg
Probable causes
The XXShPowerOn has not been executed, or to few DA_PROC task
are specified.
Recommended actions
Check if XXShPowerOn was done.
If using only DAP you should save a sys.cfg, and add a new
DA_PROCX task in that file. Check what files are loaded for
DA_PROC1 task and add them to your new task.
110216, Application error
Description
Task: arg
Attempt to install a process number
outside it's limits.
arg
arg
Recommended actions
Check the program, max number of processes are limited to 4.
110220, Application error
Description
Task: arg
The user data variable choice does not exist.
arg
arg
110221, Application error
Description
Task: arg
The user data variable has incorrect type.
arg
arg
110222, Application error
Description
Task: arg
The internal process data type lacks daintdata as first element.
arg
arg
Recommended actions
Check the program.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 355
|
6 Trouble shooting by Event log
352
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The average calibration precisions obtained in the x-, y-, z- directions
of the sensor tool are: arg . The desired ones are: arg .
Recommended actions
Verify that the calibration plate has not been moved. Check the sensor
settings. Start LTC to run a manual calibration setup followed by a new
calibration.
110178, Tracker verification error
Description
Task: arg
Sensor: arg
It was not possible to perform a valid tracker calibration verification.
Consequences
The sensor arg does not meet the calibration precision and will
therefore be unreliable for tracking.
Probable causes
The average verification precisions obtained in the x-, y-, z- directions
of the sensor tool are: arg . The desired ones are: arg .
Recommended actions
Start LTC to run a manual verification with a different number of
measurements. If problems persist, run a new manual calibration from
LTC.
110179, Left lap joint definition not correct
Description
Task: arg
Sensor: arg
The definition of the left joint (number arg ) is not correct.
Consequences
It will not be possible to perform a sensor calibration.
Probable causes
The measure obtained in the y-direction of the sensor tool on the left
lap-joint is : arg mm. The value should be positive.
Recommended actions
Check the left-lap joint definition ( arg ) in the sensor's ( arg )PC
interface. Possibly switch between the right and left lap-joint
definitions.
110180, Sensor Calibration Data updated
Description
The sensor calibration data for arg ( arg and arg ) are updated.
Task: arg
Recommended actions
If you use CAP without RW Arc, you have to rerun the RAPID
instruction
CapLATRSetup arg , arg , arg \SensorFreq:=xxx;
to make CAP use the updated sensor calibration data.
110203, Application error
Description
Task: arg
The maximum program number, 'DA_PROG_MAX' is above the num
data type limit.
Current value: arg
Consequences
The maximum configured program number will not be set.
Probable causes
The specified program number arg is above the maximum integer
value for the num data type, max value 8388608.
Recommended actions
Check the program.
110204, Application error
Description
Task: arg
Any return code other than DAOK is rejected from arg
Recommended actions
110205, Application error
Description
Task: arg
Forward sequence jumping is not allowed.
Recommended actions
Check the program sequence.
110206, Application error
Description
Task: arg
Missing I/O-signal arg .
Recommended actions
Check the I/O configuration.
110207, Application error
Description
Task: arg
Process number arg of application arg was already installed.
6 Trouble shooting by Event log
353
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
110208, Application error
Description
Task: arg
Number arg is not a valid start number.
Recommended actions
110209, Application error
Description
Task: arg
The user hook arg is not a valid sequence entry.
Recommended actions
Check the program sequence.
110210, Application error
Description
Task: arg
The program number arg is above the num data type limit.
Consequences
The program number will not be set.
Probable causes
The specified program number arg is above the maximum integer
value for the num data type, max value 8388608.
Recommended actions
Check the program.
110211, Application error
Description
Task: arg
The instruction arg reported a fatal error.
Recommended actions
110212, Application error
Description
Task: arg
arg tried to use a non existent process descriptor.
A fatal error in damastr class.
arg
Probable causes
The XXShPowerOn has not been executed.
Recommended actions
Check if XXShPowerOn was done.
110214, Application error
Description
Task: arg
arg tried to use a non existent application descriptor.
arg
Probable causes
The XXShPowerOn has not been executed, or to few DA_PROC task
are specified.
Recommended actions
Check if XXShPowerOn was done.
If using only DAP you should save a sys.cfg, and add a new
DA_PROCX task in that file. Check what files are loaded for
DA_PROC1 task and add them to your new task.
110216, Application error
Description
Task: arg
Attempt to install a process number
outside it's limits.
arg
arg
Recommended actions
Check the program, max number of processes are limited to 4.
110220, Application error
Description
Task: arg
The user data variable choice does not exist.
arg
arg
110221, Application error
Description
Task: arg
The user data variable has incorrect type.
arg
arg
110222, Application error
Description
Task: arg
The internal process data type lacks daintdata as first element.
arg
arg
Recommended actions
Check the program.
6 Trouble shooting by Event log
354
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110223, Application error
Description
Task: arg
The user data type definitions exceed the maximum data storage size.
arg
arg
Recommended actions
Check the program.
110224, Application error
Description
Task: arg
The user data type definitions does not correspond to what was
defined.
arg
arg
110226, Application error
Description
Task: arg
An error occurred while attempting to reload the Power Failure area.
An automatic restart of the processes will not be possible.
arg
arg
110229, Application error
Description
Task arg :
Error from arg . The data type definitions exceed the maximum data
storage size.
arg
Recommended actions
Check the data size.
110230, Application error
Description
Task arg :
Not possible to execute instruction in motors off state for servo tool arg
.
Recommended actions
Retry after setting motors on.
110300, Parameter error
Description
Task: arg
The max string length of the parameter arg is 5 characters.
Current used name is arg .
See specification in arg .
arg
Recommended actions
Check the length of the string data value.
110302, Parameter error
Description
Task: arg
The specified signal arg in the instruction arg has no reference.
arg
Recommended actions
Check the EIO configuration.
110303, Parameter error
Description
Task: arg
The optional signals \ arg and \ arg must be used together.
See specification in arg .
arg
Recommended actions
Check the program.
110304, Parameter error
Description
Task: arg
The parameter arg of the instruction arg is not an array.
arg
Recommended actions
Check the data definition.
110305, Parameter error
Description
Task: arg
The dimension of the data array arg is to big.
See specification in arg .
arg
Recommended actions
Check the data declaration.
110306, Parameter error
Description
Task: arg
The array arg of the instruction arg is not right defined.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 356
|
6 Trouble shooting by Event log
353
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
110208, Application error
Description
Task: arg
Number arg is not a valid start number.
Recommended actions
110209, Application error
Description
Task: arg
The user hook arg is not a valid sequence entry.
Recommended actions
Check the program sequence.
110210, Application error
Description
Task: arg
The program number arg is above the num data type limit.
Consequences
The program number will not be set.
Probable causes
The specified program number arg is above the maximum integer
value for the num data type, max value 8388608.
Recommended actions
Check the program.
110211, Application error
Description
Task: arg
The instruction arg reported a fatal error.
Recommended actions
110212, Application error
Description
Task: arg
arg tried to use a non existent process descriptor.
A fatal error in damastr class.
arg
Probable causes
The XXShPowerOn has not been executed.
Recommended actions
Check if XXShPowerOn was done.
110214, Application error
Description
Task: arg
arg tried to use a non existent application descriptor.
arg
Probable causes
The XXShPowerOn has not been executed, or to few DA_PROC task
are specified.
Recommended actions
Check if XXShPowerOn was done.
If using only DAP you should save a sys.cfg, and add a new
DA_PROCX task in that file. Check what files are loaded for
DA_PROC1 task and add them to your new task.
110216, Application error
Description
Task: arg
Attempt to install a process number
outside it's limits.
arg
arg
Recommended actions
Check the program, max number of processes are limited to 4.
110220, Application error
Description
Task: arg
The user data variable choice does not exist.
arg
arg
110221, Application error
Description
Task: arg
The user data variable has incorrect type.
arg
arg
110222, Application error
Description
Task: arg
The internal process data type lacks daintdata as first element.
arg
arg
Recommended actions
Check the program.
6 Trouble shooting by Event log
354
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110223, Application error
Description
Task: arg
The user data type definitions exceed the maximum data storage size.
arg
arg
Recommended actions
Check the program.
110224, Application error
Description
Task: arg
The user data type definitions does not correspond to what was
defined.
arg
arg
110226, Application error
Description
Task: arg
An error occurred while attempting to reload the Power Failure area.
An automatic restart of the processes will not be possible.
arg
arg
110229, Application error
Description
Task arg :
Error from arg . The data type definitions exceed the maximum data
storage size.
arg
Recommended actions
Check the data size.
110230, Application error
Description
Task arg :
Not possible to execute instruction in motors off state for servo tool arg
.
Recommended actions
Retry after setting motors on.
110300, Parameter error
Description
Task: arg
The max string length of the parameter arg is 5 characters.
Current used name is arg .
See specification in arg .
arg
Recommended actions
Check the length of the string data value.
110302, Parameter error
Description
Task: arg
The specified signal arg in the instruction arg has no reference.
arg
Recommended actions
Check the EIO configuration.
110303, Parameter error
Description
Task: arg
The optional signals \ arg and \ arg must be used together.
See specification in arg .
arg
Recommended actions
Check the program.
110304, Parameter error
Description
Task: arg
The parameter arg of the instruction arg is not an array.
arg
Recommended actions
Check the data definition.
110305, Parameter error
Description
Task: arg
The dimension of the data array arg is to big.
See specification in arg .
arg
Recommended actions
Check the data declaration.
110306, Parameter error
Description
Task: arg
The array arg of the instruction arg is not right defined.
6 Trouble shooting by Event log
355
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
arg
Recommended actions
Check the data against the specification.
110307, Parameter error
Description
Task: arg
The event time array element arg . arg is less than 0.
See specification in arg .
arg
Recommended actions
Check the time event data.
110308, Parameter error
Description
Task: arg
The data selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110309, Parameter error
Description
Task: arg
The selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110310, Parameter error
Description
Task: arg
The selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110311, No Spot task
Description
Task: arg
No motion task is configured for Spot.
arg
Probable causes
Check the configuration
110312, Wrong number of DAPROC tasks
Description
Task: arg
Error from arg . arg DA_PROC task(s) are configured in the system.
Number of daprocs must be in the interval 1 - arg .
arg
Recommended actions
Check the configuration.
110313, Not possible to activate/deactivate
Description
Task: arg
Error in arg . This daproc is not possible to activate/deactivate.
arg
Recommended actions
Check index in the daproc descriptor.
110401, Gas supervision
Description
Task: arg
arg
Gas supervision signal not set at start of welding.
Recommended actions
Check the gas equipment.
Recovery: You might want to handle errno arg in your error handler.
110402, Water supervision
Description
Task: arg
arg
Water supervision signal not set at start of welding.
Recommended actions
Check the water cooling equipment.
Recovery: You might want to handle errno arg in your error handler.
110403, Arc supervision
Description
Task: arg
arg
Arc ignition supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 357
|
6 Trouble shooting by Event log
354
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110223, Application error
Description
Task: arg
The user data type definitions exceed the maximum data storage size.
arg
arg
Recommended actions
Check the program.
110224, Application error
Description
Task: arg
The user data type definitions does not correspond to what was
defined.
arg
arg
110226, Application error
Description
Task: arg
An error occurred while attempting to reload the Power Failure area.
An automatic restart of the processes will not be possible.
arg
arg
110229, Application error
Description
Task arg :
Error from arg . The data type definitions exceed the maximum data
storage size.
arg
Recommended actions
Check the data size.
110230, Application error
Description
Task arg :
Not possible to execute instruction in motors off state for servo tool arg
.
Recommended actions
Retry after setting motors on.
110300, Parameter error
Description
Task: arg
The max string length of the parameter arg is 5 characters.
Current used name is arg .
See specification in arg .
arg
Recommended actions
Check the length of the string data value.
110302, Parameter error
Description
Task: arg
The specified signal arg in the instruction arg has no reference.
arg
Recommended actions
Check the EIO configuration.
110303, Parameter error
Description
Task: arg
The optional signals \ arg and \ arg must be used together.
See specification in arg .
arg
Recommended actions
Check the program.
110304, Parameter error
Description
Task: arg
The parameter arg of the instruction arg is not an array.
arg
Recommended actions
Check the data definition.
110305, Parameter error
Description
Task: arg
The dimension of the data array arg is to big.
See specification in arg .
arg
Recommended actions
Check the data declaration.
110306, Parameter error
Description
Task: arg
The array arg of the instruction arg is not right defined.
6 Trouble shooting by Event log
355
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
arg
Recommended actions
Check the data against the specification.
110307, Parameter error
Description
Task: arg
The event time array element arg . arg is less than 0.
See specification in arg .
arg
Recommended actions
Check the time event data.
110308, Parameter error
Description
Task: arg
The data selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110309, Parameter error
Description
Task: arg
The selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110310, Parameter error
Description
Task: arg
The selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110311, No Spot task
Description
Task: arg
No motion task is configured for Spot.
arg
Probable causes
Check the configuration
110312, Wrong number of DAPROC tasks
Description
Task: arg
Error from arg . arg DA_PROC task(s) are configured in the system.
Number of daprocs must be in the interval 1 - arg .
arg
Recommended actions
Check the configuration.
110313, Not possible to activate/deactivate
Description
Task: arg
Error in arg . This daproc is not possible to activate/deactivate.
arg
Recommended actions
Check index in the daproc descriptor.
110401, Gas supervision
Description
Task: arg
arg
Gas supervision signal not set at start of welding.
Recommended actions
Check the gas equipment.
Recovery: You might want to handle errno arg in your error handler.
110402, Water supervision
Description
Task: arg
arg
Water supervision signal not set at start of welding.
Recommended actions
Check the water cooling equipment.
Recovery: You might want to handle errno arg in your error handler.
110403, Arc supervision
Description
Task: arg
arg
Arc ignition supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
6 Trouble shooting by Event log
356
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110404, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110405, Current supervision
Description
Task: arg
arg
Current supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110406, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal not set at start of welding.
Recommended actions
Check the wirefeed unit.
Recovery: You might want to handle errno arg in your error handler.
110407, Wirestick supervision
Description
Task: arg
arg
Wirestick supervision signal set at start of welding.
Recommended actions
Check, if the wire got stuck at the object.
Recovery: You might want to handle errno arg in your error handler.
110408, Arc ignition failed
Description
Task: arg
arg
Arc ignition failed at start of welding.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110409, Schedule strobe undefined
Description
Task: arg
arg
Schedule strobe undefined.
Recommended actions
Define a weld schedule strobe input.
Recovery: You might want to handle errno arg in your error handler.
110410, Schedule transfer error
Description
Task: arg
arg
It was not possible to transfer the schedule.
Probable causes
The schedule port was busy with previous transfer.
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110411, Process stopped
Description
Task: arg
arg
Process was stopped by the digital input 'stop process'.
Recommended actions
Check the digital input 'stop process'.
Recovery: You might want to handle errno arg in your error handler.
110412, Arc fill ignition failed
Description
Task: arg
arg
Arc fill ignition failed.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110413, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Recommended actions
Check the welding equipment.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 358
|
6 Trouble shooting by Event log
355
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
arg
Recommended actions
Check the data against the specification.
110307, Parameter error
Description
Task: arg
The event time array element arg . arg is less than 0.
See specification in arg .
arg
Recommended actions
Check the time event data.
110308, Parameter error
Description
Task: arg
The data selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110309, Parameter error
Description
Task: arg
The selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110310, Parameter error
Description
Task: arg
The selector arg in the instruction arg is not valid.
arg
Recommended actions
Check the selector against the specification.
110311, No Spot task
Description
Task: arg
No motion task is configured for Spot.
arg
Probable causes
Check the configuration
110312, Wrong number of DAPROC tasks
Description
Task: arg
Error from arg . arg DA_PROC task(s) are configured in the system.
Number of daprocs must be in the interval 1 - arg .
arg
Recommended actions
Check the configuration.
110313, Not possible to activate/deactivate
Description
Task: arg
Error in arg . This daproc is not possible to activate/deactivate.
arg
Recommended actions
Check index in the daproc descriptor.
110401, Gas supervision
Description
Task: arg
arg
Gas supervision signal not set at start of welding.
Recommended actions
Check the gas equipment.
Recovery: You might want to handle errno arg in your error handler.
110402, Water supervision
Description
Task: arg
arg
Water supervision signal not set at start of welding.
Recommended actions
Check the water cooling equipment.
Recovery: You might want to handle errno arg in your error handler.
110403, Arc supervision
Description
Task: arg
arg
Arc ignition supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
6 Trouble shooting by Event log
356
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110404, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110405, Current supervision
Description
Task: arg
arg
Current supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110406, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal not set at start of welding.
Recommended actions
Check the wirefeed unit.
Recovery: You might want to handle errno arg in your error handler.
110407, Wirestick supervision
Description
Task: arg
arg
Wirestick supervision signal set at start of welding.
Recommended actions
Check, if the wire got stuck at the object.
Recovery: You might want to handle errno arg in your error handler.
110408, Arc ignition failed
Description
Task: arg
arg
Arc ignition failed at start of welding.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110409, Schedule strobe undefined
Description
Task: arg
arg
Schedule strobe undefined.
Recommended actions
Define a weld schedule strobe input.
Recovery: You might want to handle errno arg in your error handler.
110410, Schedule transfer error
Description
Task: arg
arg
It was not possible to transfer the schedule.
Probable causes
The schedule port was busy with previous transfer.
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110411, Process stopped
Description
Task: arg
arg
Process was stopped by the digital input 'stop process'.
Recommended actions
Check the digital input 'stop process'.
Recovery: You might want to handle errno arg in your error handler.
110412, Arc fill ignition failed
Description
Task: arg
arg
Arc fill ignition failed.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110413, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Recommended actions
Check the welding equipment.
6 Trouble shooting by Event log
357
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recovery: You might want to handle errno arg in your error handler.
110414, Weld supervision
Description
Task: arg
arg
Weld ignition supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110415, Weld Off Supervision timeout
Description
Task: arg
arg
The ArcEst signal was not reset at the end of the weld within the
specified time. ( arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110416, Weld Off Supervision timeout
Description
Task: arg
arg
The WeldOK signal was not reset at the end of the weld within the
specified time.
( arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110421, Gas supervision
Description
Task: arg
arg
Gas supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg min.
Recommended actions
Check the gas equipment.
Recovery: You might want to handle errno arg in your error handler.
110422, Water supervision
Description
Task: arg
arg
Water supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the cooling water equipment.
Recovery: You might want to handle errno arg in your error handler.
110423, Arc supervision
Description
Task: arg
arg
Arc supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110424, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110425, Current supervision
Description
Task: arg
arg
Current supervision signal went low during welding.
Seam name: arg
Time from weld start: arg
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 359
|
6 Trouble shooting by Event log
356
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110404, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110405, Current supervision
Description
Task: arg
arg
Current supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110406, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal not set at start of welding.
Recommended actions
Check the wirefeed unit.
Recovery: You might want to handle errno arg in your error handler.
110407, Wirestick supervision
Description
Task: arg
arg
Wirestick supervision signal set at start of welding.
Recommended actions
Check, if the wire got stuck at the object.
Recovery: You might want to handle errno arg in your error handler.
110408, Arc ignition failed
Description
Task: arg
arg
Arc ignition failed at start of welding.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110409, Schedule strobe undefined
Description
Task: arg
arg
Schedule strobe undefined.
Recommended actions
Define a weld schedule strobe input.
Recovery: You might want to handle errno arg in your error handler.
110410, Schedule transfer error
Description
Task: arg
arg
It was not possible to transfer the schedule.
Probable causes
The schedule port was busy with previous transfer.
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110411, Process stopped
Description
Task: arg
arg
Process was stopped by the digital input 'stop process'.
Recommended actions
Check the digital input 'stop process'.
Recovery: You might want to handle errno arg in your error handler.
110412, Arc fill ignition failed
Description
Task: arg
arg
Arc fill ignition failed.
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110413, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Recommended actions
Check the welding equipment.
6 Trouble shooting by Event log
357
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recovery: You might want to handle errno arg in your error handler.
110414, Weld supervision
Description
Task: arg
arg
Weld ignition supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110415, Weld Off Supervision timeout
Description
Task: arg
arg
The ArcEst signal was not reset at the end of the weld within the
specified time. ( arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110416, Weld Off Supervision timeout
Description
Task: arg
arg
The WeldOK signal was not reset at the end of the weld within the
specified time.
( arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110421, Gas supervision
Description
Task: arg
arg
Gas supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg min.
Recommended actions
Check the gas equipment.
Recovery: You might want to handle errno arg in your error handler.
110422, Water supervision
Description
Task: arg
arg
Water supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the cooling water equipment.
Recovery: You might want to handle errno arg in your error handler.
110423, Arc supervision
Description
Task: arg
arg
Arc supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110424, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110425, Current supervision
Description
Task: arg
arg
Current supervision signal went low during welding.
Seam name: arg
Time from weld start: arg
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
6 Trouble shooting by Event log
358
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110426, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal went low during welding.
Seam name: arg
Time from weld start: arg
Recommended actions
Check the wirefeed unit.
Recovery: You might want to handle errno arg in your error handler.
110427, Process stopped
Description
Task: arg
arg
Process was stopped during welding by the digital input 'stop process'.
Seam name: arg
Time from weld start: arg
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110428, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110429, Arc ignition failed
Description
Task: arg
arg
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110430, Arc fill ignition failed
Description
Task: arg
arg
Arc ignition failed during crater fill.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110431, Weld supervision
Description
Task: arg
arg
Weld supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110432, Arc ignition failed
Description
Task: arg
arg
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment. Signal WeldOK.
Recovery: You might want to handle errno arg in your error handler.
110433, Arc fill ignition failed
Description
Task: arg
arg
Arc ignition failed with signal WeldOk during crater fill.
Seam name: arg .
Time from weld start: arg .
110435, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO1 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 360
|
6 Trouble shooting by Event log
357
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recovery: You might want to handle errno arg in your error handler.
110414, Weld supervision
Description
Task: arg
arg
Weld ignition supervision signal not set at start of welding.
Recommended actions
Check the power source.
Recovery: You might want to handle errno arg in your error handler.
110415, Weld Off Supervision timeout
Description
Task: arg
arg
The ArcEst signal was not reset at the end of the weld within the
specified time. ( arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110416, Weld Off Supervision timeout
Description
Task: arg
arg
The WeldOK signal was not reset at the end of the weld within the
specified time.
( arg seconds)
Recommended actions
Check the welding equipment and/or adjust the Weld Off timeout
value,
found in Arc Equipment Properties.
110421, Gas supervision
Description
Task: arg
arg
Gas supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg min.
Recommended actions
Check the gas equipment.
Recovery: You might want to handle errno arg in your error handler.
110422, Water supervision
Description
Task: arg
arg
Water supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the cooling water equipment.
Recovery: You might want to handle errno arg in your error handler.
110423, Arc supervision
Description
Task: arg
arg
Arc supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110424, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110425, Current supervision
Description
Task: arg
arg
Current supervision signal went low during welding.
Seam name: arg
Time from weld start: arg
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
6 Trouble shooting by Event log
358
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110426, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal went low during welding.
Seam name: arg
Time from weld start: arg
Recommended actions
Check the wirefeed unit.
Recovery: You might want to handle errno arg in your error handler.
110427, Process stopped
Description
Task: arg
arg
Process was stopped during welding by the digital input 'stop process'.
Seam name: arg
Time from weld start: arg
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110428, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110429, Arc ignition failed
Description
Task: arg
arg
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110430, Arc fill ignition failed
Description
Task: arg
arg
Arc ignition failed during crater fill.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110431, Weld supervision
Description
Task: arg
arg
Weld supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110432, Arc ignition failed
Description
Task: arg
arg
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment. Signal WeldOK.
Recovery: You might want to handle errno arg in your error handler.
110433, Arc fill ignition failed
Description
Task: arg
arg
Arc ignition failed with signal WeldOk during crater fill.
Seam name: arg .
Time from weld start: arg .
110435, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO1 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
6 Trouble shooting by Event log
359
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110436, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO2 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110437, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO3 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110438, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO4 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110439, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO5 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110440, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO1 went low during
welding.
110441, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO2 went low during
welding.
110442, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO3 went low during
welding.
110443, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO4 went low during
welding.
110444, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO5 went low during
welding.
110445, Gas supervision
Description
Task: arg
arg
Gas supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110446, Water supervision
Description
Task: arg
arg
Water supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110447, Arc supervision
Description
Task: arg
arg
Arc supervision signal went low during welding.
Seam name: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 361
|
6 Trouble shooting by Event log
358
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110426, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal went low during welding.
Seam name: arg
Time from weld start: arg
Recommended actions
Check the wirefeed unit.
Recovery: You might want to handle errno arg in your error handler.
110427, Process stopped
Description
Task: arg
arg
Process was stopped during welding by the digital input 'stop process'.
Seam name: arg
Time from weld start: arg
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110428, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110429, Arc ignition failed
Description
Task: arg
arg
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110430, Arc fill ignition failed
Description
Task: arg
arg
Arc ignition failed during crater fill.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110431, Weld supervision
Description
Task: arg
arg
Weld supervision signal went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment.
Recovery: You might want to handle errno arg in your error handler.
110432, Arc ignition failed
Description
Task: arg
arg
Seam name: arg .
Time from weld start: arg .
Recommended actions
Check the welding equipment. Signal WeldOK.
Recovery: You might want to handle errno arg in your error handler.
110433, Arc fill ignition failed
Description
Task: arg
arg
Arc ignition failed with signal WeldOk during crater fill.
Seam name: arg .
Time from weld start: arg .
110435, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO1 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
6 Trouble shooting by Event log
359
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110436, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO2 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110437, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO3 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110438, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO4 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110439, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO5 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110440, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO1 went low during
welding.
110441, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO2 went low during
welding.
110442, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO3 went low during
welding.
110443, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO4 went low during
welding.
110444, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO5 went low during
welding.
110445, Gas supervision
Description
Task: arg
arg
Gas supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110446, Water supervision
Description
Task: arg
arg
Water supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110447, Arc supervision
Description
Task: arg
arg
Arc supervision signal went low during welding.
Seam name: arg
6 Trouble shooting by Event log
360
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Time from weld start: arg .
110448, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110449, Current supervision
Description
Task: arg
arg
Current supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110450, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110451, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110460, Weld Error Recovery
Description
PROC Parameters was loaded by arg
Configuration of Weld Error Recovery is Complete.
110461, Weld Error Recovery
Description
PROC Parameters for Weld Error Recovery could not be loaded in task
arg
110462, Weld Error Recovery
Description
Robot arg moved from error location.
Robot will attempt to move back to the error location.
110463, Weld Error Recovery Failed
Description
Incorrect Weld Error Recovery Usage.
A user-defined service routine must return the robot to within 50mm
of breakpoint.
Recommended actions
Re-program your service routine.
110464, EquipmentClass Error
Description
Task: arg
The Specified EquipmentClass arg could not be unloaded.
110465, EquipmentClass Error
Description
Task: arg
The Specified EquipmentClass arg could not be found at path:
arg
110466, RW Arc Installation
Description
Weld System arg (of arg installed) started in task arg
Active EquipmentClass arg
Status OK
110467, RW Arc Installation
Description
Deactivation and Unload of EquipmentClass arg failed.
110468, RW Arc Installation
Description
Weld System arg deactivated in task arg
Status OK
110469, RW Arc Installation
Description
Load and Init of EquipmentClass arg failed.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 362
|
6 Trouble shooting by Event log
359
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110436, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO2 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110437, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO3 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110438, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO4 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110439, User defined signal supervision
Description
Task: arg
arg
User defined signal defined by USERIO5 went low during welding.
Seam name: arg .
Time from weld start: arg .
Recommended actions
Recovery: You might want to handle errno arg in your error handler.
110440, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO1 went low during
welding.
110441, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO2 went low during
welding.
110442, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO3 went low during
welding.
110443, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO4 went low during
welding.
110444, User defined signal supervision
Description
Task: arg
User defined signal arg defined by USERIO5 went low during
welding.
110445, Gas supervision
Description
Task: arg
arg
Gas supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110446, Water supervision
Description
Task: arg
arg
Water supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110447, Arc supervision
Description
Task: arg
arg
Arc supervision signal went low during welding.
Seam name: arg
6 Trouble shooting by Event log
360
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Time from weld start: arg .
110448, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110449, Current supervision
Description
Task: arg
arg
Current supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110450, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110451, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110460, Weld Error Recovery
Description
PROC Parameters was loaded by arg
Configuration of Weld Error Recovery is Complete.
110461, Weld Error Recovery
Description
PROC Parameters for Weld Error Recovery could not be loaded in task
arg
110462, Weld Error Recovery
Description
Robot arg moved from error location.
Robot will attempt to move back to the error location.
110463, Weld Error Recovery Failed
Description
Incorrect Weld Error Recovery Usage.
A user-defined service routine must return the robot to within 50mm
of breakpoint.
Recommended actions
Re-program your service routine.
110464, EquipmentClass Error
Description
Task: arg
The Specified EquipmentClass arg could not be unloaded.
110465, EquipmentClass Error
Description
Task: arg
The Specified EquipmentClass arg could not be found at path:
arg
110466, RW Arc Installation
Description
Weld System arg (of arg installed) started in task arg
Active EquipmentClass arg
Status OK
110467, RW Arc Installation
Description
Deactivation and Unload of EquipmentClass arg failed.
110468, RW Arc Installation
Description
Weld System arg deactivated in task arg
Status OK
110469, RW Arc Installation
Description
Load and Init of EquipmentClass arg failed.
6 Trouble shooting by Event log
361
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110470, Configuration Parameter Error
Description
Task: arg
PROC Configuration Parameter argarg
could not be found in cfg database.
Recommended actions
Check the installation of PROC domain parameters.
110471, Undefined Signal Error
Description
arg
Failing signal during weld phase arg could not be determined.
110472, Configuration Parameter Error
Description
Task: arg
PROC Configuration Parameter argarg
is a required parameter.
Recommended actions
Check the installation of PROC domain parameters.
110473, Weld Equipment Error
Description
Task: arg
arg
Error: arg
(format: ErrorCode ErrorText)
Recommended actions
Check the Power Source.
110474, RW Arc EIO signal error
Description
There is no communication with signal arg on unit arg .
Consequences
Welding will not be possible without communication with this EIO
unit.
Recommended actions
Check the communication link with the EIO unit.
110475, Calibration variable missing
Description
Task: arg
No Calibration variable is specified in Arc Sensor Properties.
Default calibration data is used. arg = arg
Consequences
Calibration data is needed for optimal sensor performance.
110476, Calibration variable error
Description
Task: arg
The specified Calibration variable arg in in Arc Sensor Properties
could not be found in any loaded RAPID modules.
Default calibration data is used. arg = arg
Consequences
Calibration data is needed for optimal sensor performance.
Recommended actions
Check variable name in Arc Sensor Properties and make sure that the
Sensor Calibration program is loaded.
110477, Device name mismatch
Description
Task: arg
Device name arg in in Arc Sensor Properties and Communication
settings does not match.
Consequences
The same device name must be specified in both Arc Sensor Properties
and Communication settings for the sensor to work properly.
110478, Process stop due to WDM Stability
error
Description
Task: arg
arg
Consequences
RW Arc has stopped the welding process due to a Weld Data Monitor
stability infraction.
Recommended actions
See Weld Data Monitor elog for more information.
110479, Process stop due to WDM Signature
error
Description
Task: arg
arg
Consequences
RW Arc has stopped the welding process due to a Weld Data Monitor
signature infraction.
Recommended actions
See Weld Data Monitor elog for more information.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 363
|
6 Trouble shooting by Event log
360
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Time from weld start: arg .
110448, Voltage supervision
Description
Task: arg
arg
Voltage supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110449, Current supervision
Description
Task: arg
arg
Current supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110450, Wirefeed supervision
Description
Task: arg
arg
Wirefeed supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110451, Torch supervision
Description
Task: arg
arg
Torch supervision signal went low during welding.
Seam name: arg
Time from weld start: arg .
110460, Weld Error Recovery
Description
PROC Parameters was loaded by arg
Configuration of Weld Error Recovery is Complete.
110461, Weld Error Recovery
Description
PROC Parameters for Weld Error Recovery could not be loaded in task
arg
110462, Weld Error Recovery
Description
Robot arg moved from error location.
Robot will attempt to move back to the error location.
110463, Weld Error Recovery Failed
Description
Incorrect Weld Error Recovery Usage.
A user-defined service routine must return the robot to within 50mm
of breakpoint.
Recommended actions
Re-program your service routine.
110464, EquipmentClass Error
Description
Task: arg
The Specified EquipmentClass arg could not be unloaded.
110465, EquipmentClass Error
Description
Task: arg
The Specified EquipmentClass arg could not be found at path:
arg
110466, RW Arc Installation
Description
Weld System arg (of arg installed) started in task arg
Active EquipmentClass arg
Status OK
110467, RW Arc Installation
Description
Deactivation and Unload of EquipmentClass arg failed.
110468, RW Arc Installation
Description
Weld System arg deactivated in task arg
Status OK
110469, RW Arc Installation
Description
Load and Init of EquipmentClass arg failed.
6 Trouble shooting by Event log
361
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110470, Configuration Parameter Error
Description
Task: arg
PROC Configuration Parameter argarg
could not be found in cfg database.
Recommended actions
Check the installation of PROC domain parameters.
110471, Undefined Signal Error
Description
arg
Failing signal during weld phase arg could not be determined.
110472, Configuration Parameter Error
Description
Task: arg
PROC Configuration Parameter argarg
is a required parameter.
Recommended actions
Check the installation of PROC domain parameters.
110473, Weld Equipment Error
Description
Task: arg
arg
Error: arg
(format: ErrorCode ErrorText)
Recommended actions
Check the Power Source.
110474, RW Arc EIO signal error
Description
There is no communication with signal arg on unit arg .
Consequences
Welding will not be possible without communication with this EIO
unit.
Recommended actions
Check the communication link with the EIO unit.
110475, Calibration variable missing
Description
Task: arg
No Calibration variable is specified in Arc Sensor Properties.
Default calibration data is used. arg = arg
Consequences
Calibration data is needed for optimal sensor performance.
110476, Calibration variable error
Description
Task: arg
The specified Calibration variable arg in in Arc Sensor Properties
could not be found in any loaded RAPID modules.
Default calibration data is used. arg = arg
Consequences
Calibration data is needed for optimal sensor performance.
Recommended actions
Check variable name in Arc Sensor Properties and make sure that the
Sensor Calibration program is loaded.
110477, Device name mismatch
Description
Task: arg
Device name arg in in Arc Sensor Properties and Communication
settings does not match.
Consequences
The same device name must be specified in both Arc Sensor Properties
and Communication settings for the sensor to work properly.
110478, Process stop due to WDM Stability
error
Description
Task: arg
arg
Consequences
RW Arc has stopped the welding process due to a Weld Data Monitor
stability infraction.
Recommended actions
See Weld Data Monitor elog for more information.
110479, Process stop due to WDM Signature
error
Description
Task: arg
arg
Consequences
RW Arc has stopped the welding process due to a Weld Data Monitor
signature infraction.
Recommended actions
See Weld Data Monitor elog for more information.
6 Trouble shooting by Event log
362
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110480, Arc Welding Task Busy
Description
Task: arg
arg
Serious File System problem encountered.
Recommended actions
The Controller must be warmstarted to solve the problem.
110481, System Retry limit
Description
Task: arg
arg
Max number of retries has been reached on system level.
System Misc, NoOfRetry= arg
Recommended actions
Increase parameter value to avoid reaching the limit.
110482, Sensor calibration data updated
Description
Sensor calibration data updated in task: arg
Active calibration data: arg = arg
110490, Weld Error Recovery IO Error
Description
Task: arg
arg
The breakout input was left on. The external device must reset the
signal.
The Weld Error Recovery IO interface is disabled. Respond to
FlexPendant.
110491, Weld Error Recovery IO Error
Description
Task: arg
arg
Invalid response arg supplied on signal agiWER_Response.
Valid range: ( arg )
Request has been changed to Abort.
110492, Weld Error Recovery IO Error
Description
Task: arg
arg
Escape option is not available. Request has been changed to MoveOut.
110493, Weld Error Recovery IO Error
Description
Task: arg
arg
System is waiting for the diWERAck input to go low.
110494, Weld Error Recovery IO Error
Description
Task: arg
arg
Supplied value on giWER_Response ( arg ) is not within range: ( arg )
Request has been changed to: arg
110495, Weld Error Recovery IO Interface
Description
Task: arg
The Weld Error Recovery IO Interface is successfully configured for
arg
and is ready for use.
110500, Track error
Description
Task: arg
arg
The robot controller has been asking 'blindcount'(trackdata) times for
correction data from the sensor, but did not get any.
Recommended actions
Check sensor setup and trackdata. Recovery: You might want to handle
errno arg in your error handler.
110501, Track start error
Description
Task: arg
arg
Not any valid correction data from the sensor while executing the
current ArcX instruction.
Recommended actions
Check sensor setup and trackdata. Recovery: You might want to handle
errno arg in your error handler.
110502, Track correction error
Description
Task: arg
arg
The correction is too big.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 364
|
6 Trouble shooting by Event log
361
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110470, Configuration Parameter Error
Description
Task: arg
PROC Configuration Parameter argarg
could not be found in cfg database.
Recommended actions
Check the installation of PROC domain parameters.
110471, Undefined Signal Error
Description
arg
Failing signal during weld phase arg could not be determined.
110472, Configuration Parameter Error
Description
Task: arg
PROC Configuration Parameter argarg
is a required parameter.
Recommended actions
Check the installation of PROC domain parameters.
110473, Weld Equipment Error
Description
Task: arg
arg
Error: arg
(format: ErrorCode ErrorText)
Recommended actions
Check the Power Source.
110474, RW Arc EIO signal error
Description
There is no communication with signal arg on unit arg .
Consequences
Welding will not be possible without communication with this EIO
unit.
Recommended actions
Check the communication link with the EIO unit.
110475, Calibration variable missing
Description
Task: arg
No Calibration variable is specified in Arc Sensor Properties.
Default calibration data is used. arg = arg
Consequences
Calibration data is needed for optimal sensor performance.
110476, Calibration variable error
Description
Task: arg
The specified Calibration variable arg in in Arc Sensor Properties
could not be found in any loaded RAPID modules.
Default calibration data is used. arg = arg
Consequences
Calibration data is needed for optimal sensor performance.
Recommended actions
Check variable name in Arc Sensor Properties and make sure that the
Sensor Calibration program is loaded.
110477, Device name mismatch
Description
Task: arg
Device name arg in in Arc Sensor Properties and Communication
settings does not match.
Consequences
The same device name must be specified in both Arc Sensor Properties
and Communication settings for the sensor to work properly.
110478, Process stop due to WDM Stability
error
Description
Task: arg
arg
Consequences
RW Arc has stopped the welding process due to a Weld Data Monitor
stability infraction.
Recommended actions
See Weld Data Monitor elog for more information.
110479, Process stop due to WDM Signature
error
Description
Task: arg
arg
Consequences
RW Arc has stopped the welding process due to a Weld Data Monitor
signature infraction.
Recommended actions
See Weld Data Monitor elog for more information.
6 Trouble shooting by Event log
362
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110480, Arc Welding Task Busy
Description
Task: arg
arg
Serious File System problem encountered.
Recommended actions
The Controller must be warmstarted to solve the problem.
110481, System Retry limit
Description
Task: arg
arg
Max number of retries has been reached on system level.
System Misc, NoOfRetry= arg
Recommended actions
Increase parameter value to avoid reaching the limit.
110482, Sensor calibration data updated
Description
Sensor calibration data updated in task: arg
Active calibration data: arg = arg
110490, Weld Error Recovery IO Error
Description
Task: arg
arg
The breakout input was left on. The external device must reset the
signal.
The Weld Error Recovery IO interface is disabled. Respond to
FlexPendant.
110491, Weld Error Recovery IO Error
Description
Task: arg
arg
Invalid response arg supplied on signal agiWER_Response.
Valid range: ( arg )
Request has been changed to Abort.
110492, Weld Error Recovery IO Error
Description
Task: arg
arg
Escape option is not available. Request has been changed to MoveOut.
110493, Weld Error Recovery IO Error
Description
Task: arg
arg
System is waiting for the diWERAck input to go low.
110494, Weld Error Recovery IO Error
Description
Task: arg
arg
Supplied value on giWER_Response ( arg ) is not within range: ( arg )
Request has been changed to: arg
110495, Weld Error Recovery IO Interface
Description
Task: arg
The Weld Error Recovery IO Interface is successfully configured for
arg
and is ready for use.
110500, Track error
Description
Task: arg
arg
The robot controller has been asking 'blindcount'(trackdata) times for
correction data from the sensor, but did not get any.
Recommended actions
Check sensor setup and trackdata. Recovery: You might want to handle
errno arg in your error handler.
110501, Track start error
Description
Task: arg
arg
Not any valid correction data from the sensor while executing the
current ArcX instruction.
Recommended actions
Check sensor setup and trackdata. Recovery: You might want to handle
errno arg in your error handler.
110502, Track correction error
Description
Task: arg
arg
The correction is too big.
6 Trouble shooting by Event log
363
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Check that the seam definitions in the program reflect the actual
seams. 2. Increase 'max_corr' in 'trackdata'. Recovery: You might want
to handle errno arg in your error handler.
110503, Illegal arcflydata specified
Description
Task: arg
arg
The value of parameter arg in arcflydata is arg
Consequences
Flying arg will not work correctly with this value.
Recommended actions
Increase the value of arg in arcflydata to a value greater than zero.
110504, Illegal flydata combination
Description
Task: arg
arg
Flying arg is not possible with finepoint.
Consequences
There will be no flying arg
Recommended actions
Change to zonepoint in ArcX arg instruction.
110505, Illegal zonepoint specified
Description
Task: arg
arg
A zonepoint is used in the weld arg instruction without any optional
arcflydata in the instruction.
Consequences
The zonepoint will be converted to a finepoint.
Recommended actions
Add the optional argument arcflydata to the ArcX arg instruction if
flying arg is wanted.
110506, Illegal arcflydata combination
Description
Task: arg
arg
The arcflydata parameter arg has a value which is greater than the
value of parameter arg .
Consequences
The value of arg will be reduced to the value of arg .
Recommended actions
Reduce the value of parameter arg so that the value is lower than or
equal to the value of parameter arg .
110507, RW Arc EIO signal error
Description
Task: arg
arg
The value of arg for signal arg is below its minimum logical value
( arg )
Consequences
The value of signal arg will be set to the minimum value arg .
Recommended actions
Check the values of arg components in seamdata and welddata.
Change the value or change the min logical parameter for signal arg to
avoid this message.
110508, Wirestick supervision
Description
Task: arg
arg
Wirestick supervision signal set at end of welding.
Recommended actions
Check, if the wire got stuck at the object.
Recovery: You might want to handle errno arg in your errorhandler.
110601, Spot application invalid data error
Description
Task: arg
The number of configured guns in 'SW_NOF_GUNS' are less than
one(1).
Current value is arg .
Consequences
It will not be possible to run any spot instructions.
Probable causes
1. The setup data 'SW_NOF_GUNS' has been assigned a value less
than 1.
2. The user module swdefusr.sys has not been loaded correctly.
Recommended actions
1. Check the value of the data 'SW_NOF_GUNS' in the swdefusr.sys
module.
2. Check that the user module swdefusr.sys has been loaded.
110602, Spot application invalid data error
Description
Task: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 365
|
6 Trouble shooting by Event log
362
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110480, Arc Welding Task Busy
Description
Task: arg
arg
Serious File System problem encountered.
Recommended actions
The Controller must be warmstarted to solve the problem.
110481, System Retry limit
Description
Task: arg
arg
Max number of retries has been reached on system level.
System Misc, NoOfRetry= arg
Recommended actions
Increase parameter value to avoid reaching the limit.
110482, Sensor calibration data updated
Description
Sensor calibration data updated in task: arg
Active calibration data: arg = arg
110490, Weld Error Recovery IO Error
Description
Task: arg
arg
The breakout input was left on. The external device must reset the
signal.
The Weld Error Recovery IO interface is disabled. Respond to
FlexPendant.
110491, Weld Error Recovery IO Error
Description
Task: arg
arg
Invalid response arg supplied on signal agiWER_Response.
Valid range: ( arg )
Request has been changed to Abort.
110492, Weld Error Recovery IO Error
Description
Task: arg
arg
Escape option is not available. Request has been changed to MoveOut.
110493, Weld Error Recovery IO Error
Description
Task: arg
arg
System is waiting for the diWERAck input to go low.
110494, Weld Error Recovery IO Error
Description
Task: arg
arg
Supplied value on giWER_Response ( arg ) is not within range: ( arg )
Request has been changed to: arg
110495, Weld Error Recovery IO Interface
Description
Task: arg
The Weld Error Recovery IO Interface is successfully configured for
arg
and is ready for use.
110500, Track error
Description
Task: arg
arg
The robot controller has been asking 'blindcount'(trackdata) times for
correction data from the sensor, but did not get any.
Recommended actions
Check sensor setup and trackdata. Recovery: You might want to handle
errno arg in your error handler.
110501, Track start error
Description
Task: arg
arg
Not any valid correction data from the sensor while executing the
current ArcX instruction.
Recommended actions
Check sensor setup and trackdata. Recovery: You might want to handle
errno arg in your error handler.
110502, Track correction error
Description
Task: arg
arg
The correction is too big.
6 Trouble shooting by Event log
363
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Check that the seam definitions in the program reflect the actual
seams. 2. Increase 'max_corr' in 'trackdata'. Recovery: You might want
to handle errno arg in your error handler.
110503, Illegal arcflydata specified
Description
Task: arg
arg
The value of parameter arg in arcflydata is arg
Consequences
Flying arg will not work correctly with this value.
Recommended actions
Increase the value of arg in arcflydata to a value greater than zero.
110504, Illegal flydata combination
Description
Task: arg
arg
Flying arg is not possible with finepoint.
Consequences
There will be no flying arg
Recommended actions
Change to zonepoint in ArcX arg instruction.
110505, Illegal zonepoint specified
Description
Task: arg
arg
A zonepoint is used in the weld arg instruction without any optional
arcflydata in the instruction.
Consequences
The zonepoint will be converted to a finepoint.
Recommended actions
Add the optional argument arcflydata to the ArcX arg instruction if
flying arg is wanted.
110506, Illegal arcflydata combination
Description
Task: arg
arg
The arcflydata parameter arg has a value which is greater than the
value of parameter arg .
Consequences
The value of arg will be reduced to the value of arg .
Recommended actions
Reduce the value of parameter arg so that the value is lower than or
equal to the value of parameter arg .
110507, RW Arc EIO signal error
Description
Task: arg
arg
The value of arg for signal arg is below its minimum logical value
( arg )
Consequences
The value of signal arg will be set to the minimum value arg .
Recommended actions
Check the values of arg components in seamdata and welddata.
Change the value or change the min logical parameter for signal arg to
avoid this message.
110508, Wirestick supervision
Description
Task: arg
arg
Wirestick supervision signal set at end of welding.
Recommended actions
Check, if the wire got stuck at the object.
Recovery: You might want to handle errno arg in your errorhandler.
110601, Spot application invalid data error
Description
Task: arg
The number of configured guns in 'SW_NOF_GUNS' are less than
one(1).
Current value is arg .
Consequences
It will not be possible to run any spot instructions.
Probable causes
1. The setup data 'SW_NOF_GUNS' has been assigned a value less
than 1.
2. The user module swdefusr.sys has not been loaded correctly.
Recommended actions
1. Check the value of the data 'SW_NOF_GUNS' in the swdefusr.sys
module.
2. Check that the user module swdefusr.sys has been loaded.
110602, Spot application invalid data error
Description
Task: arg
6 Trouble shooting by Event log
364
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The number of configured guns in 'SW_NOF_GUNS' are more than
10.
Current value is arg .
Consequences
It will not be possible to run any spot instructions.
Probable causes
The setup data 'SW_NOF_GUNS' has been assigned a value larger
than 10.
Recommended actions
Check the value of the data 'SW_NOF_GUNS' in the swdefusr.sys
module.
110603, Spot application optional argument
error
Description
Task: arg
No optional argument has been selected.
At least one optional argument is required.
Consequences
The instruction will not work correctly.
Recommended actions
Select an optional argument for this instruction.
110604, Gun error
Description
Task: arg
arg
Can not close a closed gun, the gun is not open!
110605, Spot application pre position error
Description
Task: arg
The optional argument PrePos are less than zero(0).
Consequences
It will not be possible to run this instruction until the argument are
changed.
Recommended actions
Change the value to a higher value than zero(0).
110606, Spot application gun activation error
Description
Task: arg
The servo gun arg is not activated.
Consequences
It will not be possible to run any spot instructions until the servo gun
is activated.
Probable causes
The servo gun has not been activated before trying to run this
instruction.
Recommended actions
Activate the servo gun arg .
Use the instruction 'ActUnit' to activate the servo gun, or set the
'Activate at Start Up' motion parameter to yes.
110607, Spot application gun initialization error
Description
Task: arg
The gun position is not initialized for the servo gun arg .
A service calibration to find the gun contact position is required before
continuing the program execution.
Consequences
It will not be possible to run any spot instructions until a service
calibration is done.
Probable causes
The servo gun has probably been fine calibrated and a service
calibration has not been done.
Recommended actions
1. Run the service routine 'ManServiceCalib' to find the contact
position of the gun, use option 2 - Initialize the servo gun position.
This needs to be done after the gun has been fine calibrated.
2. If tuning a gun it is possible to turn off the gun synchronization
check, set the motion parameter 'Sync check off' to Yes.
Location: Configuration/Motion/SG_PROCESS.
110608, Spot application gun synchronization
error
Description
Task: arg
The gun position is not synchronized for the servo gun arg .
A service calibration to find the gun contact position is required before
continuing the program execution.
Consequences
It will not be possible to run any spot instructions until a service
calibration is done.
Probable causes
The revolution counters for the servo gun has probably been updated
and a service calibration has not been done.
Recommended actions
1. Run the service routine 'ManServiceCalib' to find the contact
position of the gun, use option 1 - Synchronize the servo gun position.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 366
|
6 Trouble shooting by Event log
363
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
1. Check that the seam definitions in the program reflect the actual
seams. 2. Increase 'max_corr' in 'trackdata'. Recovery: You might want
to handle errno arg in your error handler.
110503, Illegal arcflydata specified
Description
Task: arg
arg
The value of parameter arg in arcflydata is arg
Consequences
Flying arg will not work correctly with this value.
Recommended actions
Increase the value of arg in arcflydata to a value greater than zero.
110504, Illegal flydata combination
Description
Task: arg
arg
Flying arg is not possible with finepoint.
Consequences
There will be no flying arg
Recommended actions
Change to zonepoint in ArcX arg instruction.
110505, Illegal zonepoint specified
Description
Task: arg
arg
A zonepoint is used in the weld arg instruction without any optional
arcflydata in the instruction.
Consequences
The zonepoint will be converted to a finepoint.
Recommended actions
Add the optional argument arcflydata to the ArcX arg instruction if
flying arg is wanted.
110506, Illegal arcflydata combination
Description
Task: arg
arg
The arcflydata parameter arg has a value which is greater than the
value of parameter arg .
Consequences
The value of arg will be reduced to the value of arg .
Recommended actions
Reduce the value of parameter arg so that the value is lower than or
equal to the value of parameter arg .
110507, RW Arc EIO signal error
Description
Task: arg
arg
The value of arg for signal arg is below its minimum logical value
( arg )
Consequences
The value of signal arg will be set to the minimum value arg .
Recommended actions
Check the values of arg components in seamdata and welddata.
Change the value or change the min logical parameter for signal arg to
avoid this message.
110508, Wirestick supervision
Description
Task: arg
arg
Wirestick supervision signal set at end of welding.
Recommended actions
Check, if the wire got stuck at the object.
Recovery: You might want to handle errno arg in your errorhandler.
110601, Spot application invalid data error
Description
Task: arg
The number of configured guns in 'SW_NOF_GUNS' are less than
one(1).
Current value is arg .
Consequences
It will not be possible to run any spot instructions.
Probable causes
1. The setup data 'SW_NOF_GUNS' has been assigned a value less
than 1.
2. The user module swdefusr.sys has not been loaded correctly.
Recommended actions
1. Check the value of the data 'SW_NOF_GUNS' in the swdefusr.sys
module.
2. Check that the user module swdefusr.sys has been loaded.
110602, Spot application invalid data error
Description
Task: arg
6 Trouble shooting by Event log
364
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The number of configured guns in 'SW_NOF_GUNS' are more than
10.
Current value is arg .
Consequences
It will not be possible to run any spot instructions.
Probable causes
The setup data 'SW_NOF_GUNS' has been assigned a value larger
than 10.
Recommended actions
Check the value of the data 'SW_NOF_GUNS' in the swdefusr.sys
module.
110603, Spot application optional argument
error
Description
Task: arg
No optional argument has been selected.
At least one optional argument is required.
Consequences
The instruction will not work correctly.
Recommended actions
Select an optional argument for this instruction.
110604, Gun error
Description
Task: arg
arg
Can not close a closed gun, the gun is not open!
110605, Spot application pre position error
Description
Task: arg
The optional argument PrePos are less than zero(0).
Consequences
It will not be possible to run this instruction until the argument are
changed.
Recommended actions
Change the value to a higher value than zero(0).
110606, Spot application gun activation error
Description
Task: arg
The servo gun arg is not activated.
Consequences
It will not be possible to run any spot instructions until the servo gun
is activated.
Probable causes
The servo gun has not been activated before trying to run this
instruction.
Recommended actions
Activate the servo gun arg .
Use the instruction 'ActUnit' to activate the servo gun, or set the
'Activate at Start Up' motion parameter to yes.
110607, Spot application gun initialization error
Description
Task: arg
The gun position is not initialized for the servo gun arg .
A service calibration to find the gun contact position is required before
continuing the program execution.
Consequences
It will not be possible to run any spot instructions until a service
calibration is done.
Probable causes
The servo gun has probably been fine calibrated and a service
calibration has not been done.
Recommended actions
1. Run the service routine 'ManServiceCalib' to find the contact
position of the gun, use option 2 - Initialize the servo gun position.
This needs to be done after the gun has been fine calibrated.
2. If tuning a gun it is possible to turn off the gun synchronization
check, set the motion parameter 'Sync check off' to Yes.
Location: Configuration/Motion/SG_PROCESS.
110608, Spot application gun synchronization
error
Description
Task: arg
The gun position is not synchronized for the servo gun arg .
A service calibration to find the gun contact position is required before
continuing the program execution.
Consequences
It will not be possible to run any spot instructions until a service
calibration is done.
Probable causes
The revolution counters for the servo gun has probably been updated
and a service calibration has not been done.
Recommended actions
1. Run the service routine 'ManServiceCalib' to find the contact
position of the gun, use option 1 - Synchronize the servo gun position.
6 Trouble shooting by Event log
365
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This needs to be done after the revolution counters has been lost or
updated.
2. If tuning a gun it is possible to turn off the gun synchronization
check, set the motion parameter 'Sync check off' to Yes.
Location: Configuration/Motion/SG_PROCESS.
110609, Spot application no guns defined error
Description
Task: arg
No guns has been defined, the setup data 'SW_NOF_GUNS' can not be
read.
The setup data 'SW_NOF_GUNS' should be in the range of: 1 to
maximum arg .
Consequences
It will not be possible to run any spot instructions until this data has
been defined.
Probable causes
The setup data 'SW_NOF_GUNS' has been deleted or the user module
has not been loaded correctly.
Recommended actions
1. Check that the setup data is defined in the user modules and that the
modules are loaded.
2. Check that no syntax error are present in the user modules.
110610, Spot application gun name error
Description
Task: arg
The servo gun arg specified in curr_gundata{ arg }, does not exist in the
motion parameters.
Consequences
It will not be possible to run any spot instruction until the correct servo
gun name is specified in curr_gundata.
Probable causes
The gun name in curr_gundata does not match any mechanical unit in
the system or no configuration for a servo gun has been loaded.
Recommended actions
1. Run the service routine 'ManAddGunName' to search the system for
servo guns and to update the gun name parameter in curr_gundata,
2. Load motion configuration for the servo gun.
110611, Spot application invalid data error
Description
Task: arg
Invalid value of data arg . Allowed values are: 0, 1 or 2.
Current value is arg
Consequences
It will not be possible to run any spot instruction until this data is
changed.
Probable causes
A invalid value has been defined.
Recommended actions
Change the value of arg .
110612, Spot application invalid robot error
Description
Task: arg
Invalid robot number, robot number arg .
Recommended actions
Check that arg was done.
110613, Spot application invalid error id
Description
Task: arg
Invalid error number Id
Invalid use of arg .
Current Error Id: arg
Probable causes
The error number id was larger than arg .
Recommended actions
Don't use arg . This routine is for the Spot application use only.
110614, Gun error
Description
Task: arg
arg
Gun error ( arg ).
Force calibration failed. Check the values and try again. Do not restart
system until a valid force calibration is made.
Recommended actions
Check values and do a force calibration again.
110615, Spot application gun control error
Description
Task: arg
It is not possible to close or open the servo gun arg in motors off or
emergency stop state.
Consequences
The gun has not opened or closed.
Probable causes
The system was set to motors off state during process for some reason.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 367
|
6 Trouble shooting by Event log
364
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The number of configured guns in 'SW_NOF_GUNS' are more than
10.
Current value is arg .
Consequences
It will not be possible to run any spot instructions.
Probable causes
The setup data 'SW_NOF_GUNS' has been assigned a value larger
than 10.
Recommended actions
Check the value of the data 'SW_NOF_GUNS' in the swdefusr.sys
module.
110603, Spot application optional argument
error
Description
Task: arg
No optional argument has been selected.
At least one optional argument is required.
Consequences
The instruction will not work correctly.
Recommended actions
Select an optional argument for this instruction.
110604, Gun error
Description
Task: arg
arg
Can not close a closed gun, the gun is not open!
110605, Spot application pre position error
Description
Task: arg
The optional argument PrePos are less than zero(0).
Consequences
It will not be possible to run this instruction until the argument are
changed.
Recommended actions
Change the value to a higher value than zero(0).
110606, Spot application gun activation error
Description
Task: arg
The servo gun arg is not activated.
Consequences
It will not be possible to run any spot instructions until the servo gun
is activated.
Probable causes
The servo gun has not been activated before trying to run this
instruction.
Recommended actions
Activate the servo gun arg .
Use the instruction 'ActUnit' to activate the servo gun, or set the
'Activate at Start Up' motion parameter to yes.
110607, Spot application gun initialization error
Description
Task: arg
The gun position is not initialized for the servo gun arg .
A service calibration to find the gun contact position is required before
continuing the program execution.
Consequences
It will not be possible to run any spot instructions until a service
calibration is done.
Probable causes
The servo gun has probably been fine calibrated and a service
calibration has not been done.
Recommended actions
1. Run the service routine 'ManServiceCalib' to find the contact
position of the gun, use option 2 - Initialize the servo gun position.
This needs to be done after the gun has been fine calibrated.
2. If tuning a gun it is possible to turn off the gun synchronization
check, set the motion parameter 'Sync check off' to Yes.
Location: Configuration/Motion/SG_PROCESS.
110608, Spot application gun synchronization
error
Description
Task: arg
The gun position is not synchronized for the servo gun arg .
A service calibration to find the gun contact position is required before
continuing the program execution.
Consequences
It will not be possible to run any spot instructions until a service
calibration is done.
Probable causes
The revolution counters for the servo gun has probably been updated
and a service calibration has not been done.
Recommended actions
1. Run the service routine 'ManServiceCalib' to find the contact
position of the gun, use option 1 - Synchronize the servo gun position.
6 Trouble shooting by Event log
365
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This needs to be done after the revolution counters has been lost or
updated.
2. If tuning a gun it is possible to turn off the gun synchronization
check, set the motion parameter 'Sync check off' to Yes.
Location: Configuration/Motion/SG_PROCESS.
110609, Spot application no guns defined error
Description
Task: arg
No guns has been defined, the setup data 'SW_NOF_GUNS' can not be
read.
The setup data 'SW_NOF_GUNS' should be in the range of: 1 to
maximum arg .
Consequences
It will not be possible to run any spot instructions until this data has
been defined.
Probable causes
The setup data 'SW_NOF_GUNS' has been deleted or the user module
has not been loaded correctly.
Recommended actions
1. Check that the setup data is defined in the user modules and that the
modules are loaded.
2. Check that no syntax error are present in the user modules.
110610, Spot application gun name error
Description
Task: arg
The servo gun arg specified in curr_gundata{ arg }, does not exist in the
motion parameters.
Consequences
It will not be possible to run any spot instruction until the correct servo
gun name is specified in curr_gundata.
Probable causes
The gun name in curr_gundata does not match any mechanical unit in
the system or no configuration for a servo gun has been loaded.
Recommended actions
1. Run the service routine 'ManAddGunName' to search the system for
servo guns and to update the gun name parameter in curr_gundata,
2. Load motion configuration for the servo gun.
110611, Spot application invalid data error
Description
Task: arg
Invalid value of data arg . Allowed values are: 0, 1 or 2.
Current value is arg
Consequences
It will not be possible to run any spot instruction until this data is
changed.
Probable causes
A invalid value has been defined.
Recommended actions
Change the value of arg .
110612, Spot application invalid robot error
Description
Task: arg
Invalid robot number, robot number arg .
Recommended actions
Check that arg was done.
110613, Spot application invalid error id
Description
Task: arg
Invalid error number Id
Invalid use of arg .
Current Error Id: arg
Probable causes
The error number id was larger than arg .
Recommended actions
Don't use arg . This routine is for the Spot application use only.
110614, Gun error
Description
Task: arg
arg
Gun error ( arg ).
Force calibration failed. Check the values and try again. Do not restart
system until a valid force calibration is made.
Recommended actions
Check values and do a force calibration again.
110615, Spot application gun control error
Description
Task: arg
It is not possible to close or open the servo gun arg in motors off or
emergency stop state.
Consequences
The gun has not opened or closed.
Probable causes
The system was set to motors off state during process for some reason.
6 Trouble shooting by Event log
366
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Go to motors on state again and restart the instruction.
110616, Spot application weld position aborted
Description
Task: arg
The weld position was aborted, current rob target arg .
Current gun: arg
Consequences
This weld position was not welded.
The strength of the welded object has been reduced.
Probable causes
The spot instruction was aborted for some reason, the PP was moved
or the instruction was skipped.
Recommended actions
Check that it was OK to skip this position.
110617, Spot application invalid data error
Description
Task: arg
Invalid value of data 'gun_type' in curr_gundata{ arg }.
Allowed values for the gun type are: 1 = servo gun or 2 = pneumatic
gun.
Current value is arg .
Consequences
This instruction will not work properly.
Recommended actions
Change the value of 'gun_type' in curr_gundata{ arg }.
110618, Spot application invalid data error
Description
Task: arg
Invalid value of data 'pre_close_time' in curr_gundata{ arg }.
Allowed interval: 0 to max arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'pre_close_time' in curr_gundata{ arg }.
110619, Spot application invalid data error
Description
Task: arg
Invalid value of data 'pre_equ_time' in curr_gundata{ arg }.
Allowed interval: 0 to max arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'pre_equ_time' in curr_gundata{ arg }.
110620, Spot application invalid data error
Description
Task: arg
Invalid value of 'weld_timeout' in curr_gundata{ arg }.
Allowed interval: arg to arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'weld_timeout' in curr_gundata{ arg }.
110621, Spot application invalid data error
Description
Task: arg
Invalid value of the 'tip_force' parameter in spotdata.
Allowed values are: 0 to max arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'tip_force' parameter in spotdata.
110622, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_thickness' in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_thickness' parameter in spotdata.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 368
|
6 Trouble shooting by Event log
365
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
This needs to be done after the revolution counters has been lost or
updated.
2. If tuning a gun it is possible to turn off the gun synchronization
check, set the motion parameter 'Sync check off' to Yes.
Location: Configuration/Motion/SG_PROCESS.
110609, Spot application no guns defined error
Description
Task: arg
No guns has been defined, the setup data 'SW_NOF_GUNS' can not be
read.
The setup data 'SW_NOF_GUNS' should be in the range of: 1 to
maximum arg .
Consequences
It will not be possible to run any spot instructions until this data has
been defined.
Probable causes
The setup data 'SW_NOF_GUNS' has been deleted or the user module
has not been loaded correctly.
Recommended actions
1. Check that the setup data is defined in the user modules and that the
modules are loaded.
2. Check that no syntax error are present in the user modules.
110610, Spot application gun name error
Description
Task: arg
The servo gun arg specified in curr_gundata{ arg }, does not exist in the
motion parameters.
Consequences
It will not be possible to run any spot instruction until the correct servo
gun name is specified in curr_gundata.
Probable causes
The gun name in curr_gundata does not match any mechanical unit in
the system or no configuration for a servo gun has been loaded.
Recommended actions
1. Run the service routine 'ManAddGunName' to search the system for
servo guns and to update the gun name parameter in curr_gundata,
2. Load motion configuration for the servo gun.
110611, Spot application invalid data error
Description
Task: arg
Invalid value of data arg . Allowed values are: 0, 1 or 2.
Current value is arg
Consequences
It will not be possible to run any spot instruction until this data is
changed.
Probable causes
A invalid value has been defined.
Recommended actions
Change the value of arg .
110612, Spot application invalid robot error
Description
Task: arg
Invalid robot number, robot number arg .
Recommended actions
Check that arg was done.
110613, Spot application invalid error id
Description
Task: arg
Invalid error number Id
Invalid use of arg .
Current Error Id: arg
Probable causes
The error number id was larger than arg .
Recommended actions
Don't use arg . This routine is for the Spot application use only.
110614, Gun error
Description
Task: arg
arg
Gun error ( arg ).
Force calibration failed. Check the values and try again. Do not restart
system until a valid force calibration is made.
Recommended actions
Check values and do a force calibration again.
110615, Spot application gun control error
Description
Task: arg
It is not possible to close or open the servo gun arg in motors off or
emergency stop state.
Consequences
The gun has not opened or closed.
Probable causes
The system was set to motors off state during process for some reason.
6 Trouble shooting by Event log
366
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Go to motors on state again and restart the instruction.
110616, Spot application weld position aborted
Description
Task: arg
The weld position was aborted, current rob target arg .
Current gun: arg
Consequences
This weld position was not welded.
The strength of the welded object has been reduced.
Probable causes
The spot instruction was aborted for some reason, the PP was moved
or the instruction was skipped.
Recommended actions
Check that it was OK to skip this position.
110617, Spot application invalid data error
Description
Task: arg
Invalid value of data 'gun_type' in curr_gundata{ arg }.
Allowed values for the gun type are: 1 = servo gun or 2 = pneumatic
gun.
Current value is arg .
Consequences
This instruction will not work properly.
Recommended actions
Change the value of 'gun_type' in curr_gundata{ arg }.
110618, Spot application invalid data error
Description
Task: arg
Invalid value of data 'pre_close_time' in curr_gundata{ arg }.
Allowed interval: 0 to max arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'pre_close_time' in curr_gundata{ arg }.
110619, Spot application invalid data error
Description
Task: arg
Invalid value of data 'pre_equ_time' in curr_gundata{ arg }.
Allowed interval: 0 to max arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'pre_equ_time' in curr_gundata{ arg }.
110620, Spot application invalid data error
Description
Task: arg
Invalid value of 'weld_timeout' in curr_gundata{ arg }.
Allowed interval: arg to arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'weld_timeout' in curr_gundata{ arg }.
110621, Spot application invalid data error
Description
Task: arg
Invalid value of the 'tip_force' parameter in spotdata.
Allowed values are: 0 to max arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'tip_force' parameter in spotdata.
110622, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_thickness' in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_thickness' parameter in spotdata.
6 Trouble shooting by Event log
367
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110623, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_tolerance' parameter in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_tolerance' parameter in spotdata.
110624, Spot application invalid data error
Description
Task: arg
Invalid value of the 'prog_no' parameter in spotdata.
Allowed values are: 0 to max arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'prog_no' parameter in spotdata.
110625, Spot application invalid data error
Description
Task: arg
Invalid value of the 'sim_type' parameter in simdata.
Allowed values are: 0 to arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'sim_type' parameter in simdata
110626, Spot application invalid data error
Description
Task: arg
Invalid value of the 'tip_force' parameter in forcedata.
Allowed values are: 0 to arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'tip_force' parameter in forcedata.
110627, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_thickness' parameter in forcedata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_thickness' parameter in forcedata.
110628, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_tolerance' parameter in forcedata.
Allowed values are: 0 to arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_tolerance' parameter in forcedata.
110629, Spot application invalid data error
Description
Task: arg
Invalid value of the 'force_time' parameter in forcedata.
Allowed values are: arg to arg s.
Current value: arg s.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'force_time' parameter in forcedata.
110630, Spot application weld complete timeout
Description
Task: arg
arg
Current robtarget: arg
Current gun: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 369
|
6 Trouble shooting by Event log
366
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Go to motors on state again and restart the instruction.
110616, Spot application weld position aborted
Description
Task: arg
The weld position was aborted, current rob target arg .
Current gun: arg
Consequences
This weld position was not welded.
The strength of the welded object has been reduced.
Probable causes
The spot instruction was aborted for some reason, the PP was moved
or the instruction was skipped.
Recommended actions
Check that it was OK to skip this position.
110617, Spot application invalid data error
Description
Task: arg
Invalid value of data 'gun_type' in curr_gundata{ arg }.
Allowed values for the gun type are: 1 = servo gun or 2 = pneumatic
gun.
Current value is arg .
Consequences
This instruction will not work properly.
Recommended actions
Change the value of 'gun_type' in curr_gundata{ arg }.
110618, Spot application invalid data error
Description
Task: arg
Invalid value of data 'pre_close_time' in curr_gundata{ arg }.
Allowed interval: 0 to max arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'pre_close_time' in curr_gundata{ arg }.
110619, Spot application invalid data error
Description
Task: arg
Invalid value of data 'pre_equ_time' in curr_gundata{ arg }.
Allowed interval: 0 to max arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'pre_equ_time' in curr_gundata{ arg }.
110620, Spot application invalid data error
Description
Task: arg
Invalid value of 'weld_timeout' in curr_gundata{ arg }.
Allowed interval: arg to arg seconds.
Current value: arg seconds.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'weld_timeout' in curr_gundata{ arg }.
110621, Spot application invalid data error
Description
Task: arg
Invalid value of the 'tip_force' parameter in spotdata.
Allowed values are: 0 to max arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'tip_force' parameter in spotdata.
110622, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_thickness' in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_thickness' parameter in spotdata.
6 Trouble shooting by Event log
367
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110623, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_tolerance' parameter in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_tolerance' parameter in spotdata.
110624, Spot application invalid data error
Description
Task: arg
Invalid value of the 'prog_no' parameter in spotdata.
Allowed values are: 0 to max arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'prog_no' parameter in spotdata.
110625, Spot application invalid data error
Description
Task: arg
Invalid value of the 'sim_type' parameter in simdata.
Allowed values are: 0 to arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'sim_type' parameter in simdata
110626, Spot application invalid data error
Description
Task: arg
Invalid value of the 'tip_force' parameter in forcedata.
Allowed values are: 0 to arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'tip_force' parameter in forcedata.
110627, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_thickness' parameter in forcedata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_thickness' parameter in forcedata.
110628, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_tolerance' parameter in forcedata.
Allowed values are: 0 to arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_tolerance' parameter in forcedata.
110629, Spot application invalid data error
Description
Task: arg
Invalid value of the 'force_time' parameter in forcedata.
Allowed values are: arg to arg s.
Current value: arg s.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'force_time' parameter in forcedata.
110630, Spot application weld complete timeout
Description
Task: arg
arg
Current robtarget: arg
Current gun: arg
6 Trouble shooting by Event log
368
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
The weld was not completed.
Probable causes
The weld controller did not reply with weld complete within the
configured time.
Recommended actions
1. Try to reweld the position.
2. Check the weld controller for any errors.
3. Increase the weld_timeout parameter in curr_gundata{ arg }.
110631, Spot application weld error reported
Description
Task: arg
arg
Current robtarget: arg
Current gun: arg
Consequences
The weld was not completed.
Probable causes
The weld controller reported an error and stopped the current ongoing
weld.
Recommended actions
1. Try to reweld the position.
2. Check the weld controller for any errors.
110632, Current error ignored
Description
Task: arg
arg
arg
110633, Spot application no mechanical unit
error
Description
Task: arg
arg
The servo gun does not exist in the motion parameters, no servo gun
parameters has been loaded.
Current gun name: arg .
Consequences
It will not be possible to run any spot instructions until configurations
for a servo gun is added.
Probable causes
No configuration for servo gun parameters has been loaded.
Recommended actions
Load configurations for servo gun.
110634, Spot application cfg data limit error
Description
Task: arg
The data value is outside the limit.
Recommended actions
Change the value.
110635, Spot application tip position error
Description
Task: arg
Tip position error.
arg
Current gun: arg
Probable causes
1. The geometry of the plates are wrong or the tips are damaged.
2. The value of the plate_thickness parameter in arg is not the same as
the actual thickness of the plates.
Recommended actions
1. Check that the thickness of the plates are correct and corresponds to
the value in the plate_thickness parameter in arg .
2. Check that the tips are OK.
110636, Spot application process error
Description
Task: arg
Process error.
arg
arg
Current gun: arg
Consequences
The position was not welded.
Probable causes
An error occurred during the weld process.
Recommended actions
Check the welding equipment.
110637, Spot application text index too high
error
Description
Task: arg
Text index out of bounds in SwTextGet.
Current index number: arg
Probable causes
The index number is too high
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 370
|
6 Trouble shooting by Event log
367
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110623, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_tolerance' parameter in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_tolerance' parameter in spotdata.
110624, Spot application invalid data error
Description
Task: arg
Invalid value of the 'prog_no' parameter in spotdata.
Allowed values are: 0 to max arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'prog_no' parameter in spotdata.
110625, Spot application invalid data error
Description
Task: arg
Invalid value of the 'sim_type' parameter in simdata.
Allowed values are: 0 to arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'sim_type' parameter in simdata
110626, Spot application invalid data error
Description
Task: arg
Invalid value of the 'tip_force' parameter in forcedata.
Allowed values are: 0 to arg .
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'tip_force' parameter in forcedata.
110627, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_thickness' parameter in forcedata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_thickness' parameter in forcedata.
110628, Spot application invalid data error
Description
Task: arg
Invalid value of the 'plate_tolerance' parameter in forcedata.
Allowed values are: 0 to arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'plate_tolerance' parameter in forcedata.
110629, Spot application invalid data error
Description
Task: arg
Invalid value of the 'force_time' parameter in forcedata.
Allowed values are: arg to arg s.
Current value: arg s.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the 'force_time' parameter in forcedata.
110630, Spot application weld complete timeout
Description
Task: arg
arg
Current robtarget: arg
Current gun: arg
6 Trouble shooting by Event log
368
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
The weld was not completed.
Probable causes
The weld controller did not reply with weld complete within the
configured time.
Recommended actions
1. Try to reweld the position.
2. Check the weld controller for any errors.
3. Increase the weld_timeout parameter in curr_gundata{ arg }.
110631, Spot application weld error reported
Description
Task: arg
arg
Current robtarget: arg
Current gun: arg
Consequences
The weld was not completed.
Probable causes
The weld controller reported an error and stopped the current ongoing
weld.
Recommended actions
1. Try to reweld the position.
2. Check the weld controller for any errors.
110632, Current error ignored
Description
Task: arg
arg
arg
110633, Spot application no mechanical unit
error
Description
Task: arg
arg
The servo gun does not exist in the motion parameters, no servo gun
parameters has been loaded.
Current gun name: arg .
Consequences
It will not be possible to run any spot instructions until configurations
for a servo gun is added.
Probable causes
No configuration for servo gun parameters has been loaded.
Recommended actions
Load configurations for servo gun.
110634, Spot application cfg data limit error
Description
Task: arg
The data value is outside the limit.
Recommended actions
Change the value.
110635, Spot application tip position error
Description
Task: arg
Tip position error.
arg
Current gun: arg
Probable causes
1. The geometry of the plates are wrong or the tips are damaged.
2. The value of the plate_thickness parameter in arg is not the same as
the actual thickness of the plates.
Recommended actions
1. Check that the thickness of the plates are correct and corresponds to
the value in the plate_thickness parameter in arg .
2. Check that the tips are OK.
110636, Spot application process error
Description
Task: arg
Process error.
arg
arg
Current gun: arg
Consequences
The position was not welded.
Probable causes
An error occurred during the weld process.
Recommended actions
Check the welding equipment.
110637, Spot application text index too high
error
Description
Task: arg
Text index out of bounds in SwTextGet.
Current index number: arg
Probable causes
The index number is too high
6 Trouble shooting by Event log
369
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Change the index number.
110638, Gun error
Description
Task: arg
arg
arg
110639, Gun error
Description
Task: arg
arg
A ManServiceCalib is required before continuing the program
execution.
arg
110640, Spot application missing signal error
Description
Task: arg
The signal arg is missing in the EIO configuration.
Consequences
It will not be possible to use some internal functionality.
Probable causes
The signal arg was removed from the EIO configuration.
Recommended actions
Add the missing signal arg .
110641, Spot application invalid data error
Description
Task: arg
Invalid value of the sim_time parameter in simdata.
Allowed values are: 0 to arg s.
Current value: arg s.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the sim_time parameter in simdata
110642, Spot application invalid speed error
Description
Task: arg
It is not possible to run with reduced speed for SW Equalizing.
Allowed value (in percent): arg %.
arg
arg
Consequences
The instruction will not work until this value is changed.
Probable causes
The speed was probably lowered by the operator.
Recommended actions
Set the speed to arg %.
110643, Spot application gun conflict error
Description
Task: arg
More than one robot try to use the same gun at the same time.
arg
Consequences
All the robots in the system are stopped.
Probable causes
The same gun is used from more than one motion task.
Recommended actions
Change the gun number or wait for the other robot to finish. You have
to deactivate the used gun before another robot can use it. This is done
with the instruction "DeactProc".
110644, Could not save the module
Description
Task: arg
arg
Could not save the module arg
The disk is full or the file is write protected.
110645, Spot application invalid data
Description
Task: arg
Software equalizing error.
The instructions SpotML and SpotMJ can not be used with Software
Equalizing activated.
Consequences
The instruction will be stopped.
Probable causes
Software Equalizing is activated in curr_gundata.
Recommended actions
1. Do not use the instructions SpotML and SpotMJ together with
Software Equalizing.
2. Reset the 'softw_equ' variable in curr_gundata and run the
instruction without Software Equalizing.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 371
|
6 Trouble shooting by Event log
368
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
The weld was not completed.
Probable causes
The weld controller did not reply with weld complete within the
configured time.
Recommended actions
1. Try to reweld the position.
2. Check the weld controller for any errors.
3. Increase the weld_timeout parameter in curr_gundata{ arg }.
110631, Spot application weld error reported
Description
Task: arg
arg
Current robtarget: arg
Current gun: arg
Consequences
The weld was not completed.
Probable causes
The weld controller reported an error and stopped the current ongoing
weld.
Recommended actions
1. Try to reweld the position.
2. Check the weld controller for any errors.
110632, Current error ignored
Description
Task: arg
arg
arg
110633, Spot application no mechanical unit
error
Description
Task: arg
arg
The servo gun does not exist in the motion parameters, no servo gun
parameters has been loaded.
Current gun name: arg .
Consequences
It will not be possible to run any spot instructions until configurations
for a servo gun is added.
Probable causes
No configuration for servo gun parameters has been loaded.
Recommended actions
Load configurations for servo gun.
110634, Spot application cfg data limit error
Description
Task: arg
The data value is outside the limit.
Recommended actions
Change the value.
110635, Spot application tip position error
Description
Task: arg
Tip position error.
arg
Current gun: arg
Probable causes
1. The geometry of the plates are wrong or the tips are damaged.
2. The value of the plate_thickness parameter in arg is not the same as
the actual thickness of the plates.
Recommended actions
1. Check that the thickness of the plates are correct and corresponds to
the value in the plate_thickness parameter in arg .
2. Check that the tips are OK.
110636, Spot application process error
Description
Task: arg
Process error.
arg
arg
Current gun: arg
Consequences
The position was not welded.
Probable causes
An error occurred during the weld process.
Recommended actions
Check the welding equipment.
110637, Spot application text index too high
error
Description
Task: arg
Text index out of bounds in SwTextGet.
Current index number: arg
Probable causes
The index number is too high
6 Trouble shooting by Event log
369
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Change the index number.
110638, Gun error
Description
Task: arg
arg
arg
110639, Gun error
Description
Task: arg
arg
A ManServiceCalib is required before continuing the program
execution.
arg
110640, Spot application missing signal error
Description
Task: arg
The signal arg is missing in the EIO configuration.
Consequences
It will not be possible to use some internal functionality.
Probable causes
The signal arg was removed from the EIO configuration.
Recommended actions
Add the missing signal arg .
110641, Spot application invalid data error
Description
Task: arg
Invalid value of the sim_time parameter in simdata.
Allowed values are: 0 to arg s.
Current value: arg s.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the sim_time parameter in simdata
110642, Spot application invalid speed error
Description
Task: arg
It is not possible to run with reduced speed for SW Equalizing.
Allowed value (in percent): arg %.
arg
arg
Consequences
The instruction will not work until this value is changed.
Probable causes
The speed was probably lowered by the operator.
Recommended actions
Set the speed to arg %.
110643, Spot application gun conflict error
Description
Task: arg
More than one robot try to use the same gun at the same time.
arg
Consequences
All the robots in the system are stopped.
Probable causes
The same gun is used from more than one motion task.
Recommended actions
Change the gun number or wait for the other robot to finish. You have
to deactivate the used gun before another robot can use it. This is done
with the instruction "DeactProc".
110644, Could not save the module
Description
Task: arg
arg
Could not save the module arg
The disk is full or the file is write protected.
110645, Spot application invalid data
Description
Task: arg
Software equalizing error.
The instructions SpotML and SpotMJ can not be used with Software
Equalizing activated.
Consequences
The instruction will be stopped.
Probable causes
Software Equalizing is activated in curr_gundata.
Recommended actions
1. Do not use the instructions SpotML and SpotMJ together with
Software Equalizing.
2. Reset the 'softw_equ' variable in curr_gundata and run the
instruction without Software Equalizing.
6 Trouble shooting by Event log
370
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110646, Spot application invalid data
Description
Task: arg
Invalid value of release_dist in curr_gundata{ arg }.
Allowed interval: 0 to max arg mm.
Current value: arg mm.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'release_dist' in curr_gundata{ arg }
110647, Spot application invalid data
Description
Task: arg
The calculated deflection distance for this gun is invalid.
Allowed interval: - arg to max arg mm.
Current value: arg mm.
Current gun: arg
deflection = spotdata.tip_force * curr_gundata{ arg }.deflection_dist /
curr_gundata{ arg }.deflection_force
Consequences
The instruction will not work until this value is changed.
Probable causes
A too big gun deflection has been entered in curr_gundata{ arg } or the
deflection force in curr_gundata is set too low.
Recommended actions
1. Check the deflection distance in curr_gundata{ arg }.
2. Check the deflection force in curr_gundata{ arg }.
3. Check and increase the maximum limit in the setup data
'MAX_DEFLECTION' if needed.
110648, Spot application invalid data
Description
Task: arg
The value of 'deflection_time' in curr_gundata{ arg } is invalid.
Allowed values are: 0 to max arg s.
Current value: arg s.
Current gun: arg
Consequences
The instruction will not work until this value is changed.
Probable causes
A too high gun deflection time has been entered in curr_gundata{ arg }.
Recommended actions
Check the deflection time in curr_gundata{ arg }.
110649, Spot application IO error
Description
Task: arg
It is not possible to set the signal, the I/O unit is lost.
Consequences
The signal will not be set.
Probable causes
The power to the IO unit is lost or the cable is damaged.
Recommended actions
1. Check the power to IO units.
2. Check that the cabling is OK.
110650, Spot application search error
Description
Task: arg
Touch up error, no surface was found during the search sequence in
MeasureWearL
Current gun: arg
Consequences
The tool will not be updated.
Probable causes
Check for missing or wrong tips and the the reference plate is located
in the correct position.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the reference plate is in the correct position.
3. Increase the setup data arg is needed.
110651, Spot application tip range error
Description
Task: arg
New tips with unexpected size, the size of the tips exceeds the
configured tip change supervision value.
Difference between new and old (worn) tips): arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 372
|
6 Trouble shooting by Event log
369
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Change the index number.
110638, Gun error
Description
Task: arg
arg
arg
110639, Gun error
Description
Task: arg
arg
A ManServiceCalib is required before continuing the program
execution.
arg
110640, Spot application missing signal error
Description
Task: arg
The signal arg is missing in the EIO configuration.
Consequences
It will not be possible to use some internal functionality.
Probable causes
The signal arg was removed from the EIO configuration.
Recommended actions
Add the missing signal arg .
110641, Spot application invalid data error
Description
Task: arg
Invalid value of the sim_time parameter in simdata.
Allowed values are: 0 to arg s.
Current value: arg s.
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of the sim_time parameter in simdata
110642, Spot application invalid speed error
Description
Task: arg
It is not possible to run with reduced speed for SW Equalizing.
Allowed value (in percent): arg %.
arg
arg
Consequences
The instruction will not work until this value is changed.
Probable causes
The speed was probably lowered by the operator.
Recommended actions
Set the speed to arg %.
110643, Spot application gun conflict error
Description
Task: arg
More than one robot try to use the same gun at the same time.
arg
Consequences
All the robots in the system are stopped.
Probable causes
The same gun is used from more than one motion task.
Recommended actions
Change the gun number or wait for the other robot to finish. You have
to deactivate the used gun before another robot can use it. This is done
with the instruction "DeactProc".
110644, Could not save the module
Description
Task: arg
arg
Could not save the module arg
The disk is full or the file is write protected.
110645, Spot application invalid data
Description
Task: arg
Software equalizing error.
The instructions SpotML and SpotMJ can not be used with Software
Equalizing activated.
Consequences
The instruction will be stopped.
Probable causes
Software Equalizing is activated in curr_gundata.
Recommended actions
1. Do not use the instructions SpotML and SpotMJ together with
Software Equalizing.
2. Reset the 'softw_equ' variable in curr_gundata and run the
instruction without Software Equalizing.
6 Trouble shooting by Event log
370
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110646, Spot application invalid data
Description
Task: arg
Invalid value of release_dist in curr_gundata{ arg }.
Allowed interval: 0 to max arg mm.
Current value: arg mm.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'release_dist' in curr_gundata{ arg }
110647, Spot application invalid data
Description
Task: arg
The calculated deflection distance for this gun is invalid.
Allowed interval: - arg to max arg mm.
Current value: arg mm.
Current gun: arg
deflection = spotdata.tip_force * curr_gundata{ arg }.deflection_dist /
curr_gundata{ arg }.deflection_force
Consequences
The instruction will not work until this value is changed.
Probable causes
A too big gun deflection has been entered in curr_gundata{ arg } or the
deflection force in curr_gundata is set too low.
Recommended actions
1. Check the deflection distance in curr_gundata{ arg }.
2. Check the deflection force in curr_gundata{ arg }.
3. Check and increase the maximum limit in the setup data
'MAX_DEFLECTION' if needed.
110648, Spot application invalid data
Description
Task: arg
The value of 'deflection_time' in curr_gundata{ arg } is invalid.
Allowed values are: 0 to max arg s.
Current value: arg s.
Current gun: arg
Consequences
The instruction will not work until this value is changed.
Probable causes
A too high gun deflection time has been entered in curr_gundata{ arg }.
Recommended actions
Check the deflection time in curr_gundata{ arg }.
110649, Spot application IO error
Description
Task: arg
It is not possible to set the signal, the I/O unit is lost.
Consequences
The signal will not be set.
Probable causes
The power to the IO unit is lost or the cable is damaged.
Recommended actions
1. Check the power to IO units.
2. Check that the cabling is OK.
110650, Spot application search error
Description
Task: arg
Touch up error, no surface was found during the search sequence in
MeasureWearL
Current gun: arg
Consequences
The tool will not be updated.
Probable causes
Check for missing or wrong tips and the the reference plate is located
in the correct position.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the reference plate is in the correct position.
3. Increase the setup data arg is needed.
110651, Spot application tip range error
Description
Task: arg
New tips with unexpected size, the size of the tips exceeds the
configured tip change supervision value.
Difference between new and old (worn) tips): arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
6 Trouble shooting by Event log
371
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110652, Spot application touch up error
Description
Task: arg
The calculated touch up force is to high!
Overload at least of axis arg .
Probable causes
The touch up contact force is probably too high.
Recommended actions
Lower the setup data touch up contact force, 'm_touch_force'.
110653, Spot application tip range error
Description
Task: arg
New moveable tip with unexpected size, the size of the tips exceeds the
configured tip change supervision value.
Difference between new and old (worn) tips): arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
110654, Spot application tip change range error
Description
Task: arg
New fixed tip with unexpected size, the size of the tips exceeds the tip
change supervision value.
Difference between actual tip and reference tip: arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
110655, Spot application tip wear range error
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip wear
tolerance!
Actual tip wear (moveable tip): arg mm.
Tip wear tolerance: arg to arg mm.
Current gun: arg
Probable causes
The tips has probably been worn out, and the current tip wear exceeds
the maximum allowed value defined in the tip wear tolerance setup
data tipwear_superv{ arg }.
Recommended actions
Check that the maximum allowed supervision value in
tipwear_superv{ arg } is enough.
110656, Spot application tip wear range error
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip wear
tolerance!
Actual tip wear (fixed tip): arg mm.
Tip wear tolerance: arg to arg mm.
Current gun: arg
Probable causes
The tips has probably been worn out, and the current tip wear exceeds
the maximum allowed value defined in the tip wear tolerance setup
data tipwear_superv{ arg }.
Recommended actions
Check that the maximum allowed supervision value in
tipwear_superv{ arg } is enough.
110657, Spot application independent mode
error
Description
Task: arg
It is not possible to use independent mode in Spot instructions when
software equalizing is activated.
Current gun: arg
Consequences
It will not be possible to run any spot instruction until the independent
mode is deactivated.
Probable causes
The independent mode is activated.
Recommended actions
Reset the independent mode with the instruction 'IndGunMoveReset'.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 373
|
6 Trouble shooting by Event log
370
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110646, Spot application invalid data
Description
Task: arg
Invalid value of release_dist in curr_gundata{ arg }.
Allowed interval: 0 to max arg mm.
Current value: arg mm.
Current gun: arg
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Recommended actions
Change the value of 'release_dist' in curr_gundata{ arg }
110647, Spot application invalid data
Description
Task: arg
The calculated deflection distance for this gun is invalid.
Allowed interval: - arg to max arg mm.
Current value: arg mm.
Current gun: arg
deflection = spotdata.tip_force * curr_gundata{ arg }.deflection_dist /
curr_gundata{ arg }.deflection_force
Consequences
The instruction will not work until this value is changed.
Probable causes
A too big gun deflection has been entered in curr_gundata{ arg } or the
deflection force in curr_gundata is set too low.
Recommended actions
1. Check the deflection distance in curr_gundata{ arg }.
2. Check the deflection force in curr_gundata{ arg }.
3. Check and increase the maximum limit in the setup data
'MAX_DEFLECTION' if needed.
110648, Spot application invalid data
Description
Task: arg
The value of 'deflection_time' in curr_gundata{ arg } is invalid.
Allowed values are: 0 to max arg s.
Current value: arg s.
Current gun: arg
Consequences
The instruction will not work until this value is changed.
Probable causes
A too high gun deflection time has been entered in curr_gundata{ arg }.
Recommended actions
Check the deflection time in curr_gundata{ arg }.
110649, Spot application IO error
Description
Task: arg
It is not possible to set the signal, the I/O unit is lost.
Consequences
The signal will not be set.
Probable causes
The power to the IO unit is lost or the cable is damaged.
Recommended actions
1. Check the power to IO units.
2. Check that the cabling is OK.
110650, Spot application search error
Description
Task: arg
Touch up error, no surface was found during the search sequence in
MeasureWearL
Current gun: arg
Consequences
The tool will not be updated.
Probable causes
Check for missing or wrong tips and the the reference plate is located
in the correct position.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the reference plate is in the correct position.
3. Increase the setup data arg is needed.
110651, Spot application tip range error
Description
Task: arg
New tips with unexpected size, the size of the tips exceeds the
configured tip change supervision value.
Difference between new and old (worn) tips): arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
6 Trouble shooting by Event log
371
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110652, Spot application touch up error
Description
Task: arg
The calculated touch up force is to high!
Overload at least of axis arg .
Probable causes
The touch up contact force is probably too high.
Recommended actions
Lower the setup data touch up contact force, 'm_touch_force'.
110653, Spot application tip range error
Description
Task: arg
New moveable tip with unexpected size, the size of the tips exceeds the
configured tip change supervision value.
Difference between new and old (worn) tips): arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
110654, Spot application tip change range error
Description
Task: arg
New fixed tip with unexpected size, the size of the tips exceeds the tip
change supervision value.
Difference between actual tip and reference tip: arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
110655, Spot application tip wear range error
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip wear
tolerance!
Actual tip wear (moveable tip): arg mm.
Tip wear tolerance: arg to arg mm.
Current gun: arg
Probable causes
The tips has probably been worn out, and the current tip wear exceeds
the maximum allowed value defined in the tip wear tolerance setup
data tipwear_superv{ arg }.
Recommended actions
Check that the maximum allowed supervision value in
tipwear_superv{ arg } is enough.
110656, Spot application tip wear range error
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip wear
tolerance!
Actual tip wear (fixed tip): arg mm.
Tip wear tolerance: arg to arg mm.
Current gun: arg
Probable causes
The tips has probably been worn out, and the current tip wear exceeds
the maximum allowed value defined in the tip wear tolerance setup
data tipwear_superv{ arg }.
Recommended actions
Check that the maximum allowed supervision value in
tipwear_superv{ arg } is enough.
110657, Spot application independent mode
error
Description
Task: arg
It is not possible to use independent mode in Spot instructions when
software equalizing is activated.
Current gun: arg
Consequences
It will not be possible to run any spot instruction until the independent
mode is deactivated.
Probable causes
The independent mode is activated.
Recommended actions
Reset the independent mode with the instruction 'IndGunMoveReset'.
6 Trouble shooting by Event log
372
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110658, Spot application error singularity error
Description
Task: arg
The robot is close to singularity. The performance of the Software
Equalizing will be poor.
Consequences
The performance of the Software Equalizing will be poor.
Probable causes
The robot is close to singularity.
Recommended actions
Reorient the robot or move the point.
110659, Spot application robot limit error
Description
Task: arg
The robot is outside it's working area.
Consequences
The position is not possible to reach.
Probable causes
The robot is outside it's working area or the robot is very close to it
when the gun arm deflection compensation is working.
Recommended actions
Reorient the robot or move the point.
110660, Spot application user module version
warning
Description
Task: arg
The version number of the user module(s) are different than the current
spot application version.
Current version of the spot application is arg .
Currently loaded user module and version number, arg , arg .
Consequences
The spot application might not work correctly, there is a possibility that
the customizable user modules has changed since previous RobotWare
releases.
There is a risk that improvements and/or corrections added since
previous RobotWare releases are unavailable.
Probable causes
The user modules probably originates from an backup taken from an
older system.
Recommended actions
1. Check that the user modules are up to date, compare them to the
versions in this RobotWare release.
2. Load the correct module(s) and make a P-start of the system.
3. This warning can be ignored if the improvements and/or corrections
in the user modules are not critical to the customer application.
110661, Spot application error signal label error
Description
Task: arg
The 'SignalLabel' name arg is not defined in the EIO configuration.
Probable causes
The 'SignalLabel' name is not defined in the EIO configuration.
Recommended actions
1. Check that the 'SignalLabel' is defined in the EIO configuration.
2. Add the missing 'SignalLabel'.
110662, Spot application missing routine error
Description
Task: arg
A Spot user routine is missing, routine arg
This software option will not work correctly without this routine.
Consequences
This software option will not work correctly without this routine.
Probable causes
The module with the routine is not loaded or the routine has been
removed from the module.
Recommended actions
1. Check that the module with the routine is loaded.
2. Load or add the missing module or routine.
110663, Spot application user data missing
error
Description
Task: arg
A Spot user data is missing, data arg
This software option may not work correctly without this data.
Consequences
This software option may not work correctly without this data.
Probable causes
The module with the data is not loaded or the data has been removed.
Recommended actions
1. Check that the module with the data is loaded.
2. Load or add the missing module or data.
3. Ignore this warning if the data has been intentionally removed.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 374
|
6 Trouble shooting by Event log
371
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110652, Spot application touch up error
Description
Task: arg
The calculated touch up force is to high!
Overload at least of axis arg .
Probable causes
The touch up contact force is probably too high.
Recommended actions
Lower the setup data touch up contact force, 'm_touch_force'.
110653, Spot application tip range error
Description
Task: arg
New moveable tip with unexpected size, the size of the tips exceeds the
configured tip change supervision value.
Difference between new and old (worn) tips): arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
110654, Spot application tip change range error
Description
Task: arg
New fixed tip with unexpected size, the size of the tips exceeds the tip
change supervision value.
Difference between actual tip and reference tip: arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
Tips with unexpected size was mounted on the gun or the size exceeds
the maximum allowed value defined in the tip change tolerance setup
data tipchg_superv{ arg }.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value in
tipchg_superv{ arg } is enough.
110655, Spot application tip wear range error
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip wear
tolerance!
Actual tip wear (moveable tip): arg mm.
Tip wear tolerance: arg to arg mm.
Current gun: arg
Probable causes
The tips has probably been worn out, and the current tip wear exceeds
the maximum allowed value defined in the tip wear tolerance setup
data tipwear_superv{ arg }.
Recommended actions
Check that the maximum allowed supervision value in
tipwear_superv{ arg } is enough.
110656, Spot application tip wear range error
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip wear
tolerance!
Actual tip wear (fixed tip): arg mm.
Tip wear tolerance: arg to arg mm.
Current gun: arg
Probable causes
The tips has probably been worn out, and the current tip wear exceeds
the maximum allowed value defined in the tip wear tolerance setup
data tipwear_superv{ arg }.
Recommended actions
Check that the maximum allowed supervision value in
tipwear_superv{ arg } is enough.
110657, Spot application independent mode
error
Description
Task: arg
It is not possible to use independent mode in Spot instructions when
software equalizing is activated.
Current gun: arg
Consequences
It will not be possible to run any spot instruction until the independent
mode is deactivated.
Probable causes
The independent mode is activated.
Recommended actions
Reset the independent mode with the instruction 'IndGunMoveReset'.
6 Trouble shooting by Event log
372
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110658, Spot application error singularity error
Description
Task: arg
The robot is close to singularity. The performance of the Software
Equalizing will be poor.
Consequences
The performance of the Software Equalizing will be poor.
Probable causes
The robot is close to singularity.
Recommended actions
Reorient the robot or move the point.
110659, Spot application robot limit error
Description
Task: arg
The robot is outside it's working area.
Consequences
The position is not possible to reach.
Probable causes
The robot is outside it's working area or the robot is very close to it
when the gun arm deflection compensation is working.
Recommended actions
Reorient the robot or move the point.
110660, Spot application user module version
warning
Description
Task: arg
The version number of the user module(s) are different than the current
spot application version.
Current version of the spot application is arg .
Currently loaded user module and version number, arg , arg .
Consequences
The spot application might not work correctly, there is a possibility that
the customizable user modules has changed since previous RobotWare
releases.
There is a risk that improvements and/or corrections added since
previous RobotWare releases are unavailable.
Probable causes
The user modules probably originates from an backup taken from an
older system.
Recommended actions
1. Check that the user modules are up to date, compare them to the
versions in this RobotWare release.
2. Load the correct module(s) and make a P-start of the system.
3. This warning can be ignored if the improvements and/or corrections
in the user modules are not critical to the customer application.
110661, Spot application error signal label error
Description
Task: arg
The 'SignalLabel' name arg is not defined in the EIO configuration.
Probable causes
The 'SignalLabel' name is not defined in the EIO configuration.
Recommended actions
1. Check that the 'SignalLabel' is defined in the EIO configuration.
2. Add the missing 'SignalLabel'.
110662, Spot application missing routine error
Description
Task: arg
A Spot user routine is missing, routine arg
This software option will not work correctly without this routine.
Consequences
This software option will not work correctly without this routine.
Probable causes
The module with the routine is not loaded or the routine has been
removed from the module.
Recommended actions
1. Check that the module with the routine is loaded.
2. Load or add the missing module or routine.
110663, Spot application user data missing
error
Description
Task: arg
A Spot user data is missing, data arg
This software option may not work correctly without this data.
Consequences
This software option may not work correctly without this data.
Probable causes
The module with the data is not loaded or the data has been removed.
Recommended actions
1. Check that the module with the data is loaded.
2. Load or add the missing module or data.
3. Ignore this warning if the data has been intentionally removed.
6 Trouble shooting by Event log
373
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110664, Spot application sw equalizing active
error
Description
Task: arg
It is not possible to run synchronized Spot instructions when the
software equalizing mode is activated.
It is only possible to run spot instructions with software equalizing
activated in semi coordinated mode.
Consequences
It will not be possible to run any spot instructions with software
equalizing activated until the synchronized mode is disabled.
Probable causes
Synchronized mode is selected in the spot instruction.
Recommended actions
Turn off software equalizing to be able to run in synchronized mode or
change the spot instructions to semi coordinated movements instead.
110665, arg
Description
Task: arg
arg
arg
Recommended actions
arg
110666, Spot application servo gun close error
Description
Task: arg
Can not close a closed servo gun, the servo gun arg is not open!
Probable causes
The gun is already closed.
Recommended actions
Open the gun before trying to close it.
110667, Spot application force calib error
Description
Task: arg
Force calibration failed for servo gun arg .
Check the force calibration values and try again. Do not restart system
until a valid force calibration is made.
Consequences
The force calibration data will not be saved to the motion parameters.
Recommended actions
Check the values and try to do a force calibration again.
110668, Spot application thickness error
ignored
Description
Task: arg
arg
The current thickness error was ignored.
Current gun: arg
argarg
Probable causes
The operator probably ignored the thickness error.
Recommended actions
Check that it was OK to ignore the thickness error.
110669, Spot application gun number error
Description
Task: arg
The gun number arg is not a valid gun number, the gun index is out of
range.
Allowed values are: arg to max arg .
Consequences
It will not be possible run this instruction until this value is changed.
Probable causes
A gun index number that was out of range was programmed in the
instruction.
Current configured size of 'curr_gundata' is arg
Recommended actions
1. Change the gun index number in the instruction.
2. Increase the setup data 'SW_NOF_GUNS' and the spot application
data types if needed.
110670, Spot application user module changed
Description
Task: arg
The routine arg has a newer syntax, the user module has changed since
previous RobotWare releases.
Current module: arg
Current version: arg
Consequences
This instruction might not work correctly, some data(s) may not be
updated correctly.
There is a risk that improvements and/or corrections added since
previous RobotWare releases are unavailable.
Probable causes
The user modules probably originates from an backup taken from an
older system.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 375
|
6 Trouble shooting by Event log
372
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110658, Spot application error singularity error
Description
Task: arg
The robot is close to singularity. The performance of the Software
Equalizing will be poor.
Consequences
The performance of the Software Equalizing will be poor.
Probable causes
The robot is close to singularity.
Recommended actions
Reorient the robot or move the point.
110659, Spot application robot limit error
Description
Task: arg
The robot is outside it's working area.
Consequences
The position is not possible to reach.
Probable causes
The robot is outside it's working area or the robot is very close to it
when the gun arm deflection compensation is working.
Recommended actions
Reorient the robot or move the point.
110660, Spot application user module version
warning
Description
Task: arg
The version number of the user module(s) are different than the current
spot application version.
Current version of the spot application is arg .
Currently loaded user module and version number, arg , arg .
Consequences
The spot application might not work correctly, there is a possibility that
the customizable user modules has changed since previous RobotWare
releases.
There is a risk that improvements and/or corrections added since
previous RobotWare releases are unavailable.
Probable causes
The user modules probably originates from an backup taken from an
older system.
Recommended actions
1. Check that the user modules are up to date, compare them to the
versions in this RobotWare release.
2. Load the correct module(s) and make a P-start of the system.
3. This warning can be ignored if the improvements and/or corrections
in the user modules are not critical to the customer application.
110661, Spot application error signal label error
Description
Task: arg
The 'SignalLabel' name arg is not defined in the EIO configuration.
Probable causes
The 'SignalLabel' name is not defined in the EIO configuration.
Recommended actions
1. Check that the 'SignalLabel' is defined in the EIO configuration.
2. Add the missing 'SignalLabel'.
110662, Spot application missing routine error
Description
Task: arg
A Spot user routine is missing, routine arg
This software option will not work correctly without this routine.
Consequences
This software option will not work correctly without this routine.
Probable causes
The module with the routine is not loaded or the routine has been
removed from the module.
Recommended actions
1. Check that the module with the routine is loaded.
2. Load or add the missing module or routine.
110663, Spot application user data missing
error
Description
Task: arg
A Spot user data is missing, data arg
This software option may not work correctly without this data.
Consequences
This software option may not work correctly without this data.
Probable causes
The module with the data is not loaded or the data has been removed.
Recommended actions
1. Check that the module with the data is loaded.
2. Load or add the missing module or data.
3. Ignore this warning if the data has been intentionally removed.
6 Trouble shooting by Event log
373
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110664, Spot application sw equalizing active
error
Description
Task: arg
It is not possible to run synchronized Spot instructions when the
software equalizing mode is activated.
It is only possible to run spot instructions with software equalizing
activated in semi coordinated mode.
Consequences
It will not be possible to run any spot instructions with software
equalizing activated until the synchronized mode is disabled.
Probable causes
Synchronized mode is selected in the spot instruction.
Recommended actions
Turn off software equalizing to be able to run in synchronized mode or
change the spot instructions to semi coordinated movements instead.
110665, arg
Description
Task: arg
arg
arg
Recommended actions
arg
110666, Spot application servo gun close error
Description
Task: arg
Can not close a closed servo gun, the servo gun arg is not open!
Probable causes
The gun is already closed.
Recommended actions
Open the gun before trying to close it.
110667, Spot application force calib error
Description
Task: arg
Force calibration failed for servo gun arg .
Check the force calibration values and try again. Do not restart system
until a valid force calibration is made.
Consequences
The force calibration data will not be saved to the motion parameters.
Recommended actions
Check the values and try to do a force calibration again.
110668, Spot application thickness error
ignored
Description
Task: arg
arg
The current thickness error was ignored.
Current gun: arg
argarg
Probable causes
The operator probably ignored the thickness error.
Recommended actions
Check that it was OK to ignore the thickness error.
110669, Spot application gun number error
Description
Task: arg
The gun number arg is not a valid gun number, the gun index is out of
range.
Allowed values are: arg to max arg .
Consequences
It will not be possible run this instruction until this value is changed.
Probable causes
A gun index number that was out of range was programmed in the
instruction.
Current configured size of 'curr_gundata' is arg
Recommended actions
1. Change the gun index number in the instruction.
2. Increase the setup data 'SW_NOF_GUNS' and the spot application
data types if needed.
110670, Spot application user module changed
Description
Task: arg
The routine arg has a newer syntax, the user module has changed since
previous RobotWare releases.
Current module: arg
Current version: arg
Consequences
This instruction might not work correctly, some data(s) may not be
updated correctly.
There is a risk that improvements and/or corrections added since
previous RobotWare releases are unavailable.
Probable causes
The user modules probably originates from an backup taken from an
older system.
6 Trouble shooting by Event log
374
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Compare and upgrade the user modules to the latest version supplied
in this RobotWare release.
110671, Spot application error module not
saved
Description
Task: arg
Could not save the module arg .
Consequences
The module arg was not saved.
Data needed for the process was not saved and can if e.g. an p-start is
done be lost.
Probable causes
The module does not exist, or the disk is full or the file is write
protected.
Recommended actions
1. Check that the module exists in the specified location on the disk.
2. Try to save the module manually from the FlexPendant.
110672, Spot application configuration error
Description
Task: arg
The weld program number is out of limits for the defined weld
program group output (GO).
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Probable causes
The weld program signal group size is smaller than the specified weld
program.
Recommended actions
1. Increase the size of the weld program output group.
2. Decrease the weld program number.
110673, Spot application tool load definition
error
Description
Task: arg
The current used tool seems to have undefined load data.
The load of the tool is less or equal to 0 and/or the load center of gravity
is 0.
Current tool: arg .
Consequences
It will not be possible run this instruction until a correctly defined tool
is used.
Probable causes
The current tool is not correctly defined.
Recommended actions
Check that the load data for the tool is correctly defined before running
this routine.
110674, Spot application gun type error
Description
Task: arg
This routine can not be used with this type of gun.
Current gun type: arg .
Consequences
It will not be possible run this instruction with this gun type is used.
Probable causes
The 'gun_type' parameter in the used 'gundata' is not correctly defined.
Recommended actions
Check that the 'gun_type' parameter in the used 'gundata' is correctly
defined before running this routine.
110675, Spot application process task error
Description
Task: arg
The number of guns exceeds the number of activated process tasks.
Current gun: arg .
Consequences
It will not be possible to weld with more guns than the number of
activated process tasks.
Recommended actions
Configure more process tasks.
110676, Spot application power on error
Description
Task: arg
The power on sequence has not been done.
Consequences
The spot application will not work correctly.
Probable causes
An error occurred during the startup sequence.
Recommended actions
1. Check the event log for other errors occurring at the same time.
2. Correct the error and perform a p-start of the system.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 376
|
6 Trouble shooting by Event log
373
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110664, Spot application sw equalizing active
error
Description
Task: arg
It is not possible to run synchronized Spot instructions when the
software equalizing mode is activated.
It is only possible to run spot instructions with software equalizing
activated in semi coordinated mode.
Consequences
It will not be possible to run any spot instructions with software
equalizing activated until the synchronized mode is disabled.
Probable causes
Synchronized mode is selected in the spot instruction.
Recommended actions
Turn off software equalizing to be able to run in synchronized mode or
change the spot instructions to semi coordinated movements instead.
110665, arg
Description
Task: arg
arg
arg
Recommended actions
arg
110666, Spot application servo gun close error
Description
Task: arg
Can not close a closed servo gun, the servo gun arg is not open!
Probable causes
The gun is already closed.
Recommended actions
Open the gun before trying to close it.
110667, Spot application force calib error
Description
Task: arg
Force calibration failed for servo gun arg .
Check the force calibration values and try again. Do not restart system
until a valid force calibration is made.
Consequences
The force calibration data will not be saved to the motion parameters.
Recommended actions
Check the values and try to do a force calibration again.
110668, Spot application thickness error
ignored
Description
Task: arg
arg
The current thickness error was ignored.
Current gun: arg
argarg
Probable causes
The operator probably ignored the thickness error.
Recommended actions
Check that it was OK to ignore the thickness error.
110669, Spot application gun number error
Description
Task: arg
The gun number arg is not a valid gun number, the gun index is out of
range.
Allowed values are: arg to max arg .
Consequences
It will not be possible run this instruction until this value is changed.
Probable causes
A gun index number that was out of range was programmed in the
instruction.
Current configured size of 'curr_gundata' is arg
Recommended actions
1. Change the gun index number in the instruction.
2. Increase the setup data 'SW_NOF_GUNS' and the spot application
data types if needed.
110670, Spot application user module changed
Description
Task: arg
The routine arg has a newer syntax, the user module has changed since
previous RobotWare releases.
Current module: arg
Current version: arg
Consequences
This instruction might not work correctly, some data(s) may not be
updated correctly.
There is a risk that improvements and/or corrections added since
previous RobotWare releases are unavailable.
Probable causes
The user modules probably originates from an backup taken from an
older system.
6 Trouble shooting by Event log
374
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Compare and upgrade the user modules to the latest version supplied
in this RobotWare release.
110671, Spot application error module not
saved
Description
Task: arg
Could not save the module arg .
Consequences
The module arg was not saved.
Data needed for the process was not saved and can if e.g. an p-start is
done be lost.
Probable causes
The module does not exist, or the disk is full or the file is write
protected.
Recommended actions
1. Check that the module exists in the specified location on the disk.
2. Try to save the module manually from the FlexPendant.
110672, Spot application configuration error
Description
Task: arg
The weld program number is out of limits for the defined weld
program group output (GO).
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Probable causes
The weld program signal group size is smaller than the specified weld
program.
Recommended actions
1. Increase the size of the weld program output group.
2. Decrease the weld program number.
110673, Spot application tool load definition
error
Description
Task: arg
The current used tool seems to have undefined load data.
The load of the tool is less or equal to 0 and/or the load center of gravity
is 0.
Current tool: arg .
Consequences
It will not be possible run this instruction until a correctly defined tool
is used.
Probable causes
The current tool is not correctly defined.
Recommended actions
Check that the load data for the tool is correctly defined before running
this routine.
110674, Spot application gun type error
Description
Task: arg
This routine can not be used with this type of gun.
Current gun type: arg .
Consequences
It will not be possible run this instruction with this gun type is used.
Probable causes
The 'gun_type' parameter in the used 'gundata' is not correctly defined.
Recommended actions
Check that the 'gun_type' parameter in the used 'gundata' is correctly
defined before running this routine.
110675, Spot application process task error
Description
Task: arg
The number of guns exceeds the number of activated process tasks.
Current gun: arg .
Consequences
It will not be possible to weld with more guns than the number of
activated process tasks.
Recommended actions
Configure more process tasks.
110676, Spot application power on error
Description
Task: arg
The power on sequence has not been done.
Consequences
The spot application will not work correctly.
Probable causes
An error occurred during the startup sequence.
Recommended actions
1. Check the event log for other errors occurring at the same time.
2. Correct the error and perform a p-start of the system.
6 Trouble shooting by Event log
375
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110677, Spot application instruction aborted
Description
Task: arg
The instruction was aborted.
Instruction: arg
Consequences
Some data may not have been correctly updated.
Probable causes
The instruction was aborted by the operator and/or the PP was moved.
Recommended actions
Check that it was OK to abort this instruction.
110678, Spot application reference not done
error
Description
Task: arg
A reference measurement must be done before a tip wear or tip change
measurement can be done.
Instruction: arg
Probable causes
This instruction was run for the first time without the reference switch
selected.
Recommended actions
Run this instruction with the reference switch selected first.
110700, No weld internal.
Description
Task: arg
arg
Weld signal switched off at programming terminal.
Recommended actions
Check programming unit setting Operating mode for Weld on/off,
int.(S)/Weld/No weld (T).
110701, No weld external.
Description
Task: arg
arg
External weld signal was deactivated.
Recommended actions
Check signal at weld external input.
110702, The weld sequence is inhibited, weld
schedule stopped.
Description
Task: arg
arg
The started program was inhibited for the sequence/schedule
Recommended actions
Enable program at the programming terminal at Operation - Modify -
Programming - Sequence Setup Inhibit Sequence (S)/Start- Inhibit (T)
for all programs or Inhibit Sequence (P)/Start-Inhibit (P) for one
program - check program selection, select proper program.
110703, No valid weld program, no schedule
programmed.
Description
Task: arg
arg
wrong program selected - invalid spot selection - invalid parameters in
started program
Recommended actions
Check program selection - check spot selection - check value range of
the following parameters: power unit number, electrode/stepper
number, program number.
110704, The battery backup is low.
Description
Task: arg
arg
The buffer battery voltage has dropped
Recommended actions
Replace the backup battery in the weldtimer.
110705, Memory has been deleted.
Description
Task: arg
arg
All data of this weld timer has been deleted: - new timer firmware was
copied to system - battery is low or defective.
Recommended actions
Copy data (Operation - Services - Restore/Download) if the error
occurs repeatedly, replace timer.
110706, There is a hardware fault.
Description
Task: arg
arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 377
|
6 Trouble shooting by Event log
374
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Compare and upgrade the user modules to the latest version supplied
in this RobotWare release.
110671, Spot application error module not
saved
Description
Task: arg
Could not save the module arg .
Consequences
The module arg was not saved.
Data needed for the process was not saved and can if e.g. an p-start is
done be lost.
Probable causes
The module does not exist, or the disk is full or the file is write
protected.
Recommended actions
1. Check that the module exists in the specified location on the disk.
2. Try to save the module manually from the FlexPendant.
110672, Spot application configuration error
Description
Task: arg
The weld program number is out of limits for the defined weld
program group output (GO).
Current value: arg .
Consequences
It will not be possible to run any spot instructions until this value is
changed.
Probable causes
The weld program signal group size is smaller than the specified weld
program.
Recommended actions
1. Increase the size of the weld program output group.
2. Decrease the weld program number.
110673, Spot application tool load definition
error
Description
Task: arg
The current used tool seems to have undefined load data.
The load of the tool is less or equal to 0 and/or the load center of gravity
is 0.
Current tool: arg .
Consequences
It will not be possible run this instruction until a correctly defined tool
is used.
Probable causes
The current tool is not correctly defined.
Recommended actions
Check that the load data for the tool is correctly defined before running
this routine.
110674, Spot application gun type error
Description
Task: arg
This routine can not be used with this type of gun.
Current gun type: arg .
Consequences
It will not be possible run this instruction with this gun type is used.
Probable causes
The 'gun_type' parameter in the used 'gundata' is not correctly defined.
Recommended actions
Check that the 'gun_type' parameter in the used 'gundata' is correctly
defined before running this routine.
110675, Spot application process task error
Description
Task: arg
The number of guns exceeds the number of activated process tasks.
Current gun: arg .
Consequences
It will not be possible to weld with more guns than the number of
activated process tasks.
Recommended actions
Configure more process tasks.
110676, Spot application power on error
Description
Task: arg
The power on sequence has not been done.
Consequences
The spot application will not work correctly.
Probable causes
An error occurred during the startup sequence.
Recommended actions
1. Check the event log for other errors occurring at the same time.
2. Correct the error and perform a p-start of the system.
6 Trouble shooting by Event log
375
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110677, Spot application instruction aborted
Description
Task: arg
The instruction was aborted.
Instruction: arg
Consequences
Some data may not have been correctly updated.
Probable causes
The instruction was aborted by the operator and/or the PP was moved.
Recommended actions
Check that it was OK to abort this instruction.
110678, Spot application reference not done
error
Description
Task: arg
A reference measurement must be done before a tip wear or tip change
measurement can be done.
Instruction: arg
Probable causes
This instruction was run for the first time without the reference switch
selected.
Recommended actions
Run this instruction with the reference switch selected first.
110700, No weld internal.
Description
Task: arg
arg
Weld signal switched off at programming terminal.
Recommended actions
Check programming unit setting Operating mode for Weld on/off,
int.(S)/Weld/No weld (T).
110701, No weld external.
Description
Task: arg
arg
External weld signal was deactivated.
Recommended actions
Check signal at weld external input.
110702, The weld sequence is inhibited, weld
schedule stopped.
Description
Task: arg
arg
The started program was inhibited for the sequence/schedule
Recommended actions
Enable program at the programming terminal at Operation - Modify -
Programming - Sequence Setup Inhibit Sequence (S)/Start- Inhibit (T)
for all programs or Inhibit Sequence (P)/Start-Inhibit (P) for one
program - check program selection, select proper program.
110703, No valid weld program, no schedule
programmed.
Description
Task: arg
arg
wrong program selected - invalid spot selection - invalid parameters in
started program
Recommended actions
Check program selection - check spot selection - check value range of
the following parameters: power unit number, electrode/stepper
number, program number.
110704, The battery backup is low.
Description
Task: arg
arg
The buffer battery voltage has dropped
Recommended actions
Replace the backup battery in the weldtimer.
110705, Memory has been deleted.
Description
Task: arg
arg
All data of this weld timer has been deleted: - new timer firmware was
copied to system - battery is low or defective.
Recommended actions
Copy data (Operation - Services - Restore/Download) if the error
occurs repeatedly, replace timer.
110706, There is a hardware fault.
Description
Task: arg
arg
6 Trouble shooting by Event log
376
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Defective module. When booting, a module is detected which does not
match the firmware: - a firmware was introduced into the weld timer
which is not permitted for the existing hardware.
Recommended actions
Replace module or timer - replace module - load proper firmware to
the timer.
110707, External temperature too high.
Description
Task: arg
arg
Message of an external temperature input: - cable between
thermostatic switch and timer interrupted - insufficient cooling -
excessive welding heat/%I / duty cycle
Recommended actions
check cable/connector - check cooling circuit - reduce welding heat.
110708, Stop circuit open, no +24V.
Description
Task: arg
arg
+24V supply at stop circuit input missing.
Recommended actions
Close stop contact - check +24V supply at the inputs of the stop circuit.
110709, Circuit breaker tripped, weld without
command.
Description
Task: arg
arg
The timer module has activated the main switch relay: the related main
switch/circuit breaker is tripped.
Recommended actions
-
110710, Current feedback open.
Description
Task: arg
arg
Broken sensor cable - detached plug connections - incorrect connector
assignment - defective sensor.
Recommended actions
Replace cable - check plug-in connections - check connector
assignment - replace sensor.
110711, Current feedback short circuit.
Description
Task: arg
arg
Squeezed sensor cable - incorrect connector assignment - defective
sensor.
Recommended actions
Replace cable - check connector assignment - replace sensor.
110712, No primary voltage on first half wave.
Description
Task: arg
arg
No primary voltage was measured in KUR mode.
Recommended actions
Check connectors and cables.
110713, No current, weld 1 to 3.
Description
Task: arg
arg
Electrodes not closed - no electrical contact at the point to be welded -
contamination of sheets - use of sealant.
Recommended actions
Check closing mechanisms (robot, machine) - check position and
pressure of electrodes - clean sheets - check conductivity.
110714, Current is too low, weld 1 to 3.
Description
Task: arg
arg
Current measured is below tolerance band: - tolerance band too narrow
- programmed value too high, e.g., because of stepping - contamination
of electrodes - contamination of sheets - bad electrode positioning -
welding transformer too small.
Recommended actions
Check tolerance band - check programmed value, stepper values -
repeat weld, clean electrodes - repeat weld, clean sheets - improve
positioning - change over or replace welding transformer.
110715, Current is too high, weld 1 to 3.
Description
Task: arg
arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 378
|
6 Trouble shooting by Event log
375
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110677, Spot application instruction aborted
Description
Task: arg
The instruction was aborted.
Instruction: arg
Consequences
Some data may not have been correctly updated.
Probable causes
The instruction was aborted by the operator and/or the PP was moved.
Recommended actions
Check that it was OK to abort this instruction.
110678, Spot application reference not done
error
Description
Task: arg
A reference measurement must be done before a tip wear or tip change
measurement can be done.
Instruction: arg
Probable causes
This instruction was run for the first time without the reference switch
selected.
Recommended actions
Run this instruction with the reference switch selected first.
110700, No weld internal.
Description
Task: arg
arg
Weld signal switched off at programming terminal.
Recommended actions
Check programming unit setting Operating mode for Weld on/off,
int.(S)/Weld/No weld (T).
110701, No weld external.
Description
Task: arg
arg
External weld signal was deactivated.
Recommended actions
Check signal at weld external input.
110702, The weld sequence is inhibited, weld
schedule stopped.
Description
Task: arg
arg
The started program was inhibited for the sequence/schedule
Recommended actions
Enable program at the programming terminal at Operation - Modify -
Programming - Sequence Setup Inhibit Sequence (S)/Start- Inhibit (T)
for all programs or Inhibit Sequence (P)/Start-Inhibit (P) for one
program - check program selection, select proper program.
110703, No valid weld program, no schedule
programmed.
Description
Task: arg
arg
wrong program selected - invalid spot selection - invalid parameters in
started program
Recommended actions
Check program selection - check spot selection - check value range of
the following parameters: power unit number, electrode/stepper
number, program number.
110704, The battery backup is low.
Description
Task: arg
arg
The buffer battery voltage has dropped
Recommended actions
Replace the backup battery in the weldtimer.
110705, Memory has been deleted.
Description
Task: arg
arg
All data of this weld timer has been deleted: - new timer firmware was
copied to system - battery is low or defective.
Recommended actions
Copy data (Operation - Services - Restore/Download) if the error
occurs repeatedly, replace timer.
110706, There is a hardware fault.
Description
Task: arg
arg
6 Trouble shooting by Event log
376
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Defective module. When booting, a module is detected which does not
match the firmware: - a firmware was introduced into the weld timer
which is not permitted for the existing hardware.
Recommended actions
Replace module or timer - replace module - load proper firmware to
the timer.
110707, External temperature too high.
Description
Task: arg
arg
Message of an external temperature input: - cable between
thermostatic switch and timer interrupted - insufficient cooling -
excessive welding heat/%I / duty cycle
Recommended actions
check cable/connector - check cooling circuit - reduce welding heat.
110708, Stop circuit open, no +24V.
Description
Task: arg
arg
+24V supply at stop circuit input missing.
Recommended actions
Close stop contact - check +24V supply at the inputs of the stop circuit.
110709, Circuit breaker tripped, weld without
command.
Description
Task: arg
arg
The timer module has activated the main switch relay: the related main
switch/circuit breaker is tripped.
Recommended actions
-
110710, Current feedback open.
Description
Task: arg
arg
Broken sensor cable - detached plug connections - incorrect connector
assignment - defective sensor.
Recommended actions
Replace cable - check plug-in connections - check connector
assignment - replace sensor.
110711, Current feedback short circuit.
Description
Task: arg
arg
Squeezed sensor cable - incorrect connector assignment - defective
sensor.
Recommended actions
Replace cable - check connector assignment - replace sensor.
110712, No primary voltage on first half wave.
Description
Task: arg
arg
No primary voltage was measured in KUR mode.
Recommended actions
Check connectors and cables.
110713, No current, weld 1 to 3.
Description
Task: arg
arg
Electrodes not closed - no electrical contact at the point to be welded -
contamination of sheets - use of sealant.
Recommended actions
Check closing mechanisms (robot, machine) - check position and
pressure of electrodes - clean sheets - check conductivity.
110714, Current is too low, weld 1 to 3.
Description
Task: arg
arg
Current measured is below tolerance band: - tolerance band too narrow
- programmed value too high, e.g., because of stepping - contamination
of electrodes - contamination of sheets - bad electrode positioning -
welding transformer too small.
Recommended actions
Check tolerance band - check programmed value, stepper values -
repeat weld, clean electrodes - repeat weld, clean sheets - improve
positioning - change over or replace welding transformer.
110715, Current is too high, weld 1 to 3.
Description
Task: arg
arg
6 Trouble shooting by Event log
377
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Current measured exceeds tolerance band: - programmed value jump
to lower current values - handling of different sheet thicknesses or
sheet layers - variant electrode pressure conditions - variant resistances
(impedance) in secondary circuit, e.g. shunt resistor - mains voltage
fluctuations.
Recommended actions
Increase tolerance band, reduce programmed value jumps - use several
programs with different parameters - check electrode force system -
check secondary circuit - increase tolerance band, ensure constant
conditions.
110716, Current is low in consecutive welds,
weld 1 to 3.
Description
Task: arg
arg
Current measured is below the limited tolerance band after n
repetitions: - programmed value jump to higher current values -
handling of different sheet thicknesses or sheet layers - variant
electrode pressure conditions - variant resistance conditions in
secondary circuit - mains voltage fluctuations.
Recommended actions
Value jumps - use several programs with different parameters - check
electrode force system - ensure constant conditions - increase tolerance
band, ensure constant conditions.
110717, Weld time is too short, weld 1 to 3.
Description
Task: arg
arg
The permitted time tolerance is not reached - external termination of
weld signal.
Recommended actions
Check setting at Operation - Modify - Programming - Welding
parameters - Time monitoring - check signal.
110718, Weld time is too long, weld 1 to 3.
Description
Task: arg
arg
The permitted time tolerance is exceeded.
Recommended actions
Check setting at Operation - Modify - Programming - Welding
parameters - Time monitoring.
110719, Faulty configuration
Description
Number of configured weld timers are arg .
The configuration file(s) for Bosch weld timer interface does not
contain all expected data.
Consequences
The Bosch weld timer interface will not be able to connect to any weld
timer.
Probable causes
Wrong version or corrupt configuration file(s).
Recommended actions
1. Re-install correct Bosch weld timer interface configuration files.
2. Check internal elog messages.
110720, Data value outside limits.
Description
Task: arg
Program Ref. arg
The value of 'TimerNo' is outside limits, current value: arg .
Allowed values are: 1 to arg .
Consequences
The instruction will not work until a valid value is entered.
Probable causes
An invalid value was entered.
Recommended actions
Change the value.
Recovery: arg
110721, Timer not connected
Description
Weld timer not connected, timer arg .
Consequences
It will not be possible to access the timer.
Probable causes
Faulty configuration or disconnected hardware.
Recommended actions
1. Check configuration and cables.
2. Check internal elog messages.
110722, Unknown fault in weld timer.
Description
Task: arg
arg
There is a unknown fault in the weld timer, code arg .
Recommended actions
Connect the BOS5000/6000 application and check the reason for the
fault.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 379
|
6 Trouble shooting by Event log
376
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Defective module. When booting, a module is detected which does not
match the firmware: - a firmware was introduced into the weld timer
which is not permitted for the existing hardware.
Recommended actions
Replace module or timer - replace module - load proper firmware to
the timer.
110707, External temperature too high.
Description
Task: arg
arg
Message of an external temperature input: - cable between
thermostatic switch and timer interrupted - insufficient cooling -
excessive welding heat/%I / duty cycle
Recommended actions
check cable/connector - check cooling circuit - reduce welding heat.
110708, Stop circuit open, no +24V.
Description
Task: arg
arg
+24V supply at stop circuit input missing.
Recommended actions
Close stop contact - check +24V supply at the inputs of the stop circuit.
110709, Circuit breaker tripped, weld without
command.
Description
Task: arg
arg
The timer module has activated the main switch relay: the related main
switch/circuit breaker is tripped.
Recommended actions
-
110710, Current feedback open.
Description
Task: arg
arg
Broken sensor cable - detached plug connections - incorrect connector
assignment - defective sensor.
Recommended actions
Replace cable - check plug-in connections - check connector
assignment - replace sensor.
110711, Current feedback short circuit.
Description
Task: arg
arg
Squeezed sensor cable - incorrect connector assignment - defective
sensor.
Recommended actions
Replace cable - check connector assignment - replace sensor.
110712, No primary voltage on first half wave.
Description
Task: arg
arg
No primary voltage was measured in KUR mode.
Recommended actions
Check connectors and cables.
110713, No current, weld 1 to 3.
Description
Task: arg
arg
Electrodes not closed - no electrical contact at the point to be welded -
contamination of sheets - use of sealant.
Recommended actions
Check closing mechanisms (robot, machine) - check position and
pressure of electrodes - clean sheets - check conductivity.
110714, Current is too low, weld 1 to 3.
Description
Task: arg
arg
Current measured is below tolerance band: - tolerance band too narrow
- programmed value too high, e.g., because of stepping - contamination
of electrodes - contamination of sheets - bad electrode positioning -
welding transformer too small.
Recommended actions
Check tolerance band - check programmed value, stepper values -
repeat weld, clean electrodes - repeat weld, clean sheets - improve
positioning - change over or replace welding transformer.
110715, Current is too high, weld 1 to 3.
Description
Task: arg
arg
6 Trouble shooting by Event log
377
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Current measured exceeds tolerance band: - programmed value jump
to lower current values - handling of different sheet thicknesses or
sheet layers - variant electrode pressure conditions - variant resistances
(impedance) in secondary circuit, e.g. shunt resistor - mains voltage
fluctuations.
Recommended actions
Increase tolerance band, reduce programmed value jumps - use several
programs with different parameters - check electrode force system -
check secondary circuit - increase tolerance band, ensure constant
conditions.
110716, Current is low in consecutive welds,
weld 1 to 3.
Description
Task: arg
arg
Current measured is below the limited tolerance band after n
repetitions: - programmed value jump to higher current values -
handling of different sheet thicknesses or sheet layers - variant
electrode pressure conditions - variant resistance conditions in
secondary circuit - mains voltage fluctuations.
Recommended actions
Value jumps - use several programs with different parameters - check
electrode force system - ensure constant conditions - increase tolerance
band, ensure constant conditions.
110717, Weld time is too short, weld 1 to 3.
Description
Task: arg
arg
The permitted time tolerance is not reached - external termination of
weld signal.
Recommended actions
Check setting at Operation - Modify - Programming - Welding
parameters - Time monitoring - check signal.
110718, Weld time is too long, weld 1 to 3.
Description
Task: arg
arg
The permitted time tolerance is exceeded.
Recommended actions
Check setting at Operation - Modify - Programming - Welding
parameters - Time monitoring.
110719, Faulty configuration
Description
Number of configured weld timers are arg .
The configuration file(s) for Bosch weld timer interface does not
contain all expected data.
Consequences
The Bosch weld timer interface will not be able to connect to any weld
timer.
Probable causes
Wrong version or corrupt configuration file(s).
Recommended actions
1. Re-install correct Bosch weld timer interface configuration files.
2. Check internal elog messages.
110720, Data value outside limits.
Description
Task: arg
Program Ref. arg
The value of 'TimerNo' is outside limits, current value: arg .
Allowed values are: 1 to arg .
Consequences
The instruction will not work until a valid value is entered.
Probable causes
An invalid value was entered.
Recommended actions
Change the value.
Recovery: arg
110721, Timer not connected
Description
Weld timer not connected, timer arg .
Consequences
It will not be possible to access the timer.
Probable causes
Faulty configuration or disconnected hardware.
Recommended actions
1. Check configuration and cables.
2. Check internal elog messages.
110722, Unknown fault in weld timer.
Description
Task: arg
arg
There is a unknown fault in the weld timer, code arg .
Recommended actions
Connect the BOS5000/6000 application and check the reason for the
fault.
6 Trouble shooting by Event log
378
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110723, Power unit not ready.
Description
Task: arg
arg
The power unit temperature is too high.
Recommended actions
1. Check cooling.
2. Check duty cycle, load.
3. Check cables, connectors.
110724, 27~V Synchronisation, power fault.
Description
Task: arg
arg
Welding network has been switched off, or is outside the range of 50
to 60 Hz +- 5%.
Recommended actions
1. Switch on and check weldin network.
2. Reset error, check all line phases.
3. Check synchronisation voltage.
4. Check fuses in power unit or replace power unit.
110725, 24V off or too low.
Description
Task: arg
arg
The 24V supply for the internal logic is too low(approx. 19V).
Recommended actions
1. Check 24V supply.
2. Check the connectors.
110726, Transformer temperature too high.
Description
Task: arg
arg
The temperature of the welding transformer is too high.
Recommended actions
1. Check cables and connectors.
2. Check cooling circuit of the welding transformer.
3. Reduce welding heat.
110727, Cooling temperature too high.
Description
Task: arg
arg
The heat sink is too hot(above 70ºC) or the ambient temperature is too
high(above 70ºC).
Recommended actions
1. Check cooling.
2. Check duty cycle, load.
3. Check temperature inside the process cabinet or check process
cabinet cooling.
110728, IO bus fault.
Description
Task: arg
arg
The serial IO module has signalled a bus fault to the timer module.
Recommended actions
Replace IO module or timer.
110729, Electrode life has expired, end of
stepper.
Description
Task: arg
arg
The specified electrode has reached the Electrode life Expired, End of
stepper condition.
Recommended actions
The electrode must be replaced.
110730, Tip dress request.
Description
Task: arg
arg
The specified electrode has reached the Tip dress request, Tip dress
inq. condition.
Recommended actions
The electrode tip must be dressed.
110760, Tool Change Error
Description
Task: arg
arg
arg
arg
Recommended actions
arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 380
|
6 Trouble shooting by Event log
377
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Current measured exceeds tolerance band: - programmed value jump
to lower current values - handling of different sheet thicknesses or
sheet layers - variant electrode pressure conditions - variant resistances
(impedance) in secondary circuit, e.g. shunt resistor - mains voltage
fluctuations.
Recommended actions
Increase tolerance band, reduce programmed value jumps - use several
programs with different parameters - check electrode force system -
check secondary circuit - increase tolerance band, ensure constant
conditions.
110716, Current is low in consecutive welds,
weld 1 to 3.
Description
Task: arg
arg
Current measured is below the limited tolerance band after n
repetitions: - programmed value jump to higher current values -
handling of different sheet thicknesses or sheet layers - variant
electrode pressure conditions - variant resistance conditions in
secondary circuit - mains voltage fluctuations.
Recommended actions
Value jumps - use several programs with different parameters - check
electrode force system - ensure constant conditions - increase tolerance
band, ensure constant conditions.
110717, Weld time is too short, weld 1 to 3.
Description
Task: arg
arg
The permitted time tolerance is not reached - external termination of
weld signal.
Recommended actions
Check setting at Operation - Modify - Programming - Welding
parameters - Time monitoring - check signal.
110718, Weld time is too long, weld 1 to 3.
Description
Task: arg
arg
The permitted time tolerance is exceeded.
Recommended actions
Check setting at Operation - Modify - Programming - Welding
parameters - Time monitoring.
110719, Faulty configuration
Description
Number of configured weld timers are arg .
The configuration file(s) for Bosch weld timer interface does not
contain all expected data.
Consequences
The Bosch weld timer interface will not be able to connect to any weld
timer.
Probable causes
Wrong version or corrupt configuration file(s).
Recommended actions
1. Re-install correct Bosch weld timer interface configuration files.
2. Check internal elog messages.
110720, Data value outside limits.
Description
Task: arg
Program Ref. arg
The value of 'TimerNo' is outside limits, current value: arg .
Allowed values are: 1 to arg .
Consequences
The instruction will not work until a valid value is entered.
Probable causes
An invalid value was entered.
Recommended actions
Change the value.
Recovery: arg
110721, Timer not connected
Description
Weld timer not connected, timer arg .
Consequences
It will not be possible to access the timer.
Probable causes
Faulty configuration or disconnected hardware.
Recommended actions
1. Check configuration and cables.
2. Check internal elog messages.
110722, Unknown fault in weld timer.
Description
Task: arg
arg
There is a unknown fault in the weld timer, code arg .
Recommended actions
Connect the BOS5000/6000 application and check the reason for the
fault.
6 Trouble shooting by Event log
378
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110723, Power unit not ready.
Description
Task: arg
arg
The power unit temperature is too high.
Recommended actions
1. Check cooling.
2. Check duty cycle, load.
3. Check cables, connectors.
110724, 27~V Synchronisation, power fault.
Description
Task: arg
arg
Welding network has been switched off, or is outside the range of 50
to 60 Hz +- 5%.
Recommended actions
1. Switch on and check weldin network.
2. Reset error, check all line phases.
3. Check synchronisation voltage.
4. Check fuses in power unit or replace power unit.
110725, 24V off or too low.
Description
Task: arg
arg
The 24V supply for the internal logic is too low(approx. 19V).
Recommended actions
1. Check 24V supply.
2. Check the connectors.
110726, Transformer temperature too high.
Description
Task: arg
arg
The temperature of the welding transformer is too high.
Recommended actions
1. Check cables and connectors.
2. Check cooling circuit of the welding transformer.
3. Reduce welding heat.
110727, Cooling temperature too high.
Description
Task: arg
arg
The heat sink is too hot(above 70ºC) or the ambient temperature is too
high(above 70ºC).
Recommended actions
1. Check cooling.
2. Check duty cycle, load.
3. Check temperature inside the process cabinet or check process
cabinet cooling.
110728, IO bus fault.
Description
Task: arg
arg
The serial IO module has signalled a bus fault to the timer module.
Recommended actions
Replace IO module or timer.
110729, Electrode life has expired, end of
stepper.
Description
Task: arg
arg
The specified electrode has reached the Electrode life Expired, End of
stepper condition.
Recommended actions
The electrode must be replaced.
110730, Tip dress request.
Description
Task: arg
arg
The specified electrode has reached the Tip dress request, Tip dress
inq. condition.
Recommended actions
The electrode tip must be dressed.
110760, Tool Change Error
Description
Task: arg
arg
arg
arg
Recommended actions
arg
6 Trouble shooting by Event log
379
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110790, Medar WT: No contact with Medar.
Description
No communication with Medar weld timer arg , or the Medar unit does
not respond.
No contact on address arg .
Recommended actions
1.Check the address.
2.Check the serial cable.
3.Check the Medar unit.
110801, Dispense Error
Description
Task: arg
arg
Not possible to start without On argument.
arg
Recommended actions
Add On switch to first instruction.
110802, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_fl1_corr is out of limits.
arg
110803, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_fl2_corr is out of limits.
arg
110804, Dispense Error
Description
Task: arg
arg
Value for flow1_type in beaddata is out of limits.
arg
110805, Dispense Error
Description
Task: arg
arg
Value for flow2_type in beaddata is out of limits.
arg
110806, Dispense Error
Description
Task: arg
arg
Not possible to use two On instructions in sequence.
arg
Recommended actions
Remove one instruction with On switch.
110807, Dispense Error
Description
Task: arg
arg
Value for fl1_delay in equipdata is out of limits.
arg
110808, Dispense Error
Description
Task: arg
arg
Value for fl2_delay in equipdata is out of limits.
arg
110809, Dispense Error
Description
Task: arg
arg
Value for ref_speed in equipdata is out of limits.
arg
110810, Dispense Error
Description
Task: arg
arg
Value for equip_no in beaddata is out of limits.
arg
110811, Dispense Error
Description
Task: arg
arg
Unexpected Stop. Stopped while dispensing was active.
arg
arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 381
|
6 Trouble shooting by Event log
378
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110723, Power unit not ready.
Description
Task: arg
arg
The power unit temperature is too high.
Recommended actions
1. Check cooling.
2. Check duty cycle, load.
3. Check cables, connectors.
110724, 27~V Synchronisation, power fault.
Description
Task: arg
arg
Welding network has been switched off, or is outside the range of 50
to 60 Hz +- 5%.
Recommended actions
1. Switch on and check weldin network.
2. Reset error, check all line phases.
3. Check synchronisation voltage.
4. Check fuses in power unit or replace power unit.
110725, 24V off or too low.
Description
Task: arg
arg
The 24V supply for the internal logic is too low(approx. 19V).
Recommended actions
1. Check 24V supply.
2. Check the connectors.
110726, Transformer temperature too high.
Description
Task: arg
arg
The temperature of the welding transformer is too high.
Recommended actions
1. Check cables and connectors.
2. Check cooling circuit of the welding transformer.
3. Reduce welding heat.
110727, Cooling temperature too high.
Description
Task: arg
arg
The heat sink is too hot(above 70ºC) or the ambient temperature is too
high(above 70ºC).
Recommended actions
1. Check cooling.
2. Check duty cycle, load.
3. Check temperature inside the process cabinet or check process
cabinet cooling.
110728, IO bus fault.
Description
Task: arg
arg
The serial IO module has signalled a bus fault to the timer module.
Recommended actions
Replace IO module or timer.
110729, Electrode life has expired, end of
stepper.
Description
Task: arg
arg
The specified electrode has reached the Electrode life Expired, End of
stepper condition.
Recommended actions
The electrode must be replaced.
110730, Tip dress request.
Description
Task: arg
arg
The specified electrode has reached the Tip dress request, Tip dress
inq. condition.
Recommended actions
The electrode tip must be dressed.
110760, Tool Change Error
Description
Task: arg
arg
arg
arg
Recommended actions
arg
6 Trouble shooting by Event log
379
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110790, Medar WT: No contact with Medar.
Description
No communication with Medar weld timer arg , or the Medar unit does
not respond.
No contact on address arg .
Recommended actions
1.Check the address.
2.Check the serial cable.
3.Check the Medar unit.
110801, Dispense Error
Description
Task: arg
arg
Not possible to start without On argument.
arg
Recommended actions
Add On switch to first instruction.
110802, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_fl1_corr is out of limits.
arg
110803, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_fl2_corr is out of limits.
arg
110804, Dispense Error
Description
Task: arg
arg
Value for flow1_type in beaddata is out of limits.
arg
110805, Dispense Error
Description
Task: arg
arg
Value for flow2_type in beaddata is out of limits.
arg
110806, Dispense Error
Description
Task: arg
arg
Not possible to use two On instructions in sequence.
arg
Recommended actions
Remove one instruction with On switch.
110807, Dispense Error
Description
Task: arg
arg
Value for fl1_delay in equipdata is out of limits.
arg
110808, Dispense Error
Description
Task: arg
arg
Value for fl2_delay in equipdata is out of limits.
arg
110809, Dispense Error
Description
Task: arg
arg
Value for ref_speed in equipdata is out of limits.
arg
110810, Dispense Error
Description
Task: arg
arg
Value for equip_no in beaddata is out of limits.
arg
110811, Dispense Error
Description
Task: arg
arg
Unexpected Stop. Stopped while dispensing was active.
arg
arg
6 Trouble shooting by Event log
380
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110812, Dispense Error
Description
Task: arg
arg
Unknown error during dispensing.
arg
110813, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_nof_equip is out of limits.
arg
110814, Dispense Error
Description
Task: arg
arg
Value for flow1 in beaddata is out of limits.
arg
110815, Dispense Error
Description
Task: arg
arg
Value for flow2 in beaddata is out of limits.
arg
110816, Dispense Error
Description
Task: arg
arg
Value for fl1_corr in equipdata is out of limits.
arg
110817, Dispense Error
Description
Task: arg
arg
Value for fl2_corr in equipdata is out of limits.
arg
110818, Dispense Error
Description
Task: arg
arg
Not possible to change equipment in the middle of a string.
arg
110819, Dispense Error
Description
Task: arg
arg
Value for acc_max or decel_max in equipdata is too low.
arg
110820, Dispense Error
Description
Task: arg
arg
The calculated flow value is out of limits.
arg
110821, Dispense Error
Description
Task: arg
arg
fl1_delay or fl2_delay in equipdata is out of limits.
arg
111000, Itemsource exists
Description
Itemsource arg already exists.
Two itemsources may not have the same name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111001, Not a valid itemsource name
Description
Name arg is not a valid itemsource name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111002, Buffer size exceeded
Description
Fatal internal error for itemsource arg .
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 382
|
6 Trouble shooting by Event log
379
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110790, Medar WT: No contact with Medar.
Description
No communication with Medar weld timer arg , or the Medar unit does
not respond.
No contact on address arg .
Recommended actions
1.Check the address.
2.Check the serial cable.
3.Check the Medar unit.
110801, Dispense Error
Description
Task: arg
arg
Not possible to start without On argument.
arg
Recommended actions
Add On switch to first instruction.
110802, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_fl1_corr is out of limits.
arg
110803, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_fl2_corr is out of limits.
arg
110804, Dispense Error
Description
Task: arg
arg
Value for flow1_type in beaddata is out of limits.
arg
110805, Dispense Error
Description
Task: arg
arg
Value for flow2_type in beaddata is out of limits.
arg
110806, Dispense Error
Description
Task: arg
arg
Not possible to use two On instructions in sequence.
arg
Recommended actions
Remove one instruction with On switch.
110807, Dispense Error
Description
Task: arg
arg
Value for fl1_delay in equipdata is out of limits.
arg
110808, Dispense Error
Description
Task: arg
arg
Value for fl2_delay in equipdata is out of limits.
arg
110809, Dispense Error
Description
Task: arg
arg
Value for ref_speed in equipdata is out of limits.
arg
110810, Dispense Error
Description
Task: arg
arg
Value for equip_no in beaddata is out of limits.
arg
110811, Dispense Error
Description
Task: arg
arg
Unexpected Stop. Stopped while dispensing was active.
arg
arg
6 Trouble shooting by Event log
380
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110812, Dispense Error
Description
Task: arg
arg
Unknown error during dispensing.
arg
110813, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_nof_equip is out of limits.
arg
110814, Dispense Error
Description
Task: arg
arg
Value for flow1 in beaddata is out of limits.
arg
110815, Dispense Error
Description
Task: arg
arg
Value for flow2 in beaddata is out of limits.
arg
110816, Dispense Error
Description
Task: arg
arg
Value for fl1_corr in equipdata is out of limits.
arg
110817, Dispense Error
Description
Task: arg
arg
Value for fl2_corr in equipdata is out of limits.
arg
110818, Dispense Error
Description
Task: arg
arg
Not possible to change equipment in the middle of a string.
arg
110819, Dispense Error
Description
Task: arg
arg
Value for acc_max or decel_max in equipdata is too low.
arg
110820, Dispense Error
Description
Task: arg
arg
The calculated flow value is out of limits.
arg
110821, Dispense Error
Description
Task: arg
arg
fl1_delay or fl2_delay in equipdata is out of limits.
arg
111000, Itemsource exists
Description
Itemsource arg already exists.
Two itemsources may not have the same name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111001, Not a valid itemsource name
Description
Name arg is not a valid itemsource name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111002, Buffer size exceeded
Description
Fatal internal error for itemsource arg .
6 Trouble shooting by Event log
381
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Try warm start or cold start. Please report this error.
111003, Itemsource not defined
Description
The itemsource object has not been defined.
Recommended actions
Check itemsource at:
arg
Recovery: arg
111004, Itmsrc internal error
Description
Internal error for itemsource arg .
Error type: arg .
Recommended actions
Instruction: arg
Recovery: arg
111005, Flush itemsource first
Description
Itemsource arg must be flushed before it is used.
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111006, Ack item target first
Description
Item target must be acknowledged before executing the GetItmTgt(s)
instruction again.
Itemsource: arg .
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111007, Item target buffer full
Description
Item target buffer full for itemsource arg .
Recommended actions
Instruction: arg
Recovery: arg
111008, Too many item targets
Description
Too many item targets pushed to itemsource arg .
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111009, Conveyor eio init error
Description
Error in the initialisation of the I/O signals for itemsource arg , for
conveyor arg .
Recommended actions
Instruction: arg
Recovery: arg
111010, Conveyor does not exist
Description
Error for itemsource arg .
The conveyor arg
does not exist.
Recommended actions
Instruction: arg
Recovery: arg
111011, No conveyor name given
Description
Error for itemsource arg .
No conveyor name specified.
Recommended actions
Instruction: arg
Recovery: arg
111012, Conveyor limits error
Description
Error for itemsource arg , conveyor arg .
The limits are incorrect specified.
Recommended actions
Instruction: arg
Recovery: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 383
|
6 Trouble shooting by Event log
380
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
110812, Dispense Error
Description
Task: arg
arg
Unknown error during dispensing.
arg
110813, Dispense Error
Description
Task: arg
arg
Value for DPUSER data dp_nof_equip is out of limits.
arg
110814, Dispense Error
Description
Task: arg
arg
Value for flow1 in beaddata is out of limits.
arg
110815, Dispense Error
Description
Task: arg
arg
Value for flow2 in beaddata is out of limits.
arg
110816, Dispense Error
Description
Task: arg
arg
Value for fl1_corr in equipdata is out of limits.
arg
110817, Dispense Error
Description
Task: arg
arg
Value for fl2_corr in equipdata is out of limits.
arg
110818, Dispense Error
Description
Task: arg
arg
Not possible to change equipment in the middle of a string.
arg
110819, Dispense Error
Description
Task: arg
arg
Value for acc_max or decel_max in equipdata is too low.
arg
110820, Dispense Error
Description
Task: arg
arg
The calculated flow value is out of limits.
arg
110821, Dispense Error
Description
Task: arg
arg
fl1_delay or fl2_delay in equipdata is out of limits.
arg
111000, Itemsource exists
Description
Itemsource arg already exists.
Two itemsources may not have the same name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111001, Not a valid itemsource name
Description
Name arg is not a valid itemsource name.
Recommended actions
Check itemsource name at:
arg
Recovery: arg
111002, Buffer size exceeded
Description
Fatal internal error for itemsource arg .
6 Trouble shooting by Event log
381
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Try warm start or cold start. Please report this error.
111003, Itemsource not defined
Description
The itemsource object has not been defined.
Recommended actions
Check itemsource at:
arg
Recovery: arg
111004, Itmsrc internal error
Description
Internal error for itemsource arg .
Error type: arg .
Recommended actions
Instruction: arg
Recovery: arg
111005, Flush itemsource first
Description
Itemsource arg must be flushed before it is used.
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111006, Ack item target first
Description
Item target must be acknowledged before executing the GetItmTgt(s)
instruction again.
Itemsource: arg .
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111007, Item target buffer full
Description
Item target buffer full for itemsource arg .
Recommended actions
Instruction: arg
Recovery: arg
111008, Too many item targets
Description
Too many item targets pushed to itemsource arg .
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111009, Conveyor eio init error
Description
Error in the initialisation of the I/O signals for itemsource arg , for
conveyor arg .
Recommended actions
Instruction: arg
Recovery: arg
111010, Conveyor does not exist
Description
Error for itemsource arg .
The conveyor arg
does not exist.
Recommended actions
Instruction: arg
Recovery: arg
111011, No conveyor name given
Description
Error for itemsource arg .
No conveyor name specified.
Recommended actions
Instruction: arg
Recovery: arg
111012, Conveyor limits error
Description
Error for itemsource arg , conveyor arg .
The limits are incorrect specified.
Recommended actions
Instruction: arg
Recovery: arg
6 Trouble shooting by Event log
382
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111013, Cnv data defined late
Description
Error for itemsource arg , conveyor arg . The ItmSrcCnvDat instruction
must be called before the ItmSrcFlush instruction.
arg
Recommended actions
Instruction: arg
Recovery: arg
111014, Timeout
Description
Instruction reached timeout
Recommended actions
Instruction: arg
Recovery: arg
111015, Sortdata overridden
Description
Use of selection data will override the sortdata.
Recommended actions
Instruction: arg
Recovery: arg
111016, Orientation error
Description
The orientation in selection data is not correct defined.
Itemsource: arg
Recommended actions
All used orientations must be normalized i.e. the sum of the quaternion
elements squares must equal 1.
Instruction: arg
Recovery: arg
111017, Uplink message failed
Description
The system failed to send a rapid uplink message
Consequences
Program execution may run as expected.
Statistics may not be updated.
Probable causes
Network interrupt.
CPU overload in controller system.
CPU overload in remote system.
Remote system may not run as expected.
Recommended actions
Check network connection.
Check state of remote system.
Check robot program for infinite loops.
111100, Work object buffer full
Description
Too many conveyor strobes stored in
buffer for itemsource arg
In queue index: arg
Out queue index: arg
111101, Item target buffer full
Description
Item target buffer full for itemsource arg .
Item tag: arg .
Scene number arg .
111102, Too many item targets
Description
Too many item targets pushed to itemsource arg .
Number of items: arg .
Scene number arg .
111103, Push without any strobe
Description
Push received without any corresponding strobe signal is received for
itemsource arg .
Push scene number arg
Latest received strobe arg
Recommended actions
Check hardware connections
111104, Push received too late
Description
Push of items was received too late in itemsource arg .
Corresponding wobj already overwritten.
Push scene number arg .
Latest received strobe arg .
Recommended actions
Check the position generation frequency.
111105, Conveyor limits error
Description
Error in itemsource arg
Conveyor arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 384
|
6 Trouble shooting by Event log
381
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Try warm start or cold start. Please report this error.
111003, Itemsource not defined
Description
The itemsource object has not been defined.
Recommended actions
Check itemsource at:
arg
Recovery: arg
111004, Itmsrc internal error
Description
Internal error for itemsource arg .
Error type: arg .
Recommended actions
Instruction: arg
Recovery: arg
111005, Flush itemsource first
Description
Itemsource arg must be flushed before it is used.
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111006, Ack item target first
Description
Item target must be acknowledged before executing the GetItmTgt(s)
instruction again.
Itemsource: arg .
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111007, Item target buffer full
Description
Item target buffer full for itemsource arg .
Recommended actions
Instruction: arg
Recovery: arg
111008, Too many item targets
Description
Too many item targets pushed to itemsource arg .
arg
arg
Recommended actions
Instruction: arg
Recovery: arg
111009, Conveyor eio init error
Description
Error in the initialisation of the I/O signals for itemsource arg , for
conveyor arg .
Recommended actions
Instruction: arg
Recovery: arg
111010, Conveyor does not exist
Description
Error for itemsource arg .
The conveyor arg
does not exist.
Recommended actions
Instruction: arg
Recovery: arg
111011, No conveyor name given
Description
Error for itemsource arg .
No conveyor name specified.
Recommended actions
Instruction: arg
Recovery: arg
111012, Conveyor limits error
Description
Error for itemsource arg , conveyor arg .
The limits are incorrect specified.
Recommended actions
Instruction: arg
Recovery: arg
6 Trouble shooting by Event log
382
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111013, Cnv data defined late
Description
Error for itemsource arg , conveyor arg . The ItmSrcCnvDat instruction
must be called before the ItmSrcFlush instruction.
arg
Recommended actions
Instruction: arg
Recovery: arg
111014, Timeout
Description
Instruction reached timeout
Recommended actions
Instruction: arg
Recovery: arg
111015, Sortdata overridden
Description
Use of selection data will override the sortdata.
Recommended actions
Instruction: arg
Recovery: arg
111016, Orientation error
Description
The orientation in selection data is not correct defined.
Itemsource: arg
Recommended actions
All used orientations must be normalized i.e. the sum of the quaternion
elements squares must equal 1.
Instruction: arg
Recovery: arg
111017, Uplink message failed
Description
The system failed to send a rapid uplink message
Consequences
Program execution may run as expected.
Statistics may not be updated.
Probable causes
Network interrupt.
CPU overload in controller system.
CPU overload in remote system.
Remote system may not run as expected.
Recommended actions
Check network connection.
Check state of remote system.
Check robot program for infinite loops.
111100, Work object buffer full
Description
Too many conveyor strobes stored in
buffer for itemsource arg
In queue index: arg
Out queue index: arg
111101, Item target buffer full
Description
Item target buffer full for itemsource arg .
Item tag: arg .
Scene number arg .
111102, Too many item targets
Description
Too many item targets pushed to itemsource arg .
Number of items: arg .
Scene number arg .
111103, Push without any strobe
Description
Push received without any corresponding strobe signal is received for
itemsource arg .
Push scene number arg
Latest received strobe arg
Recommended actions
Check hardware connections
111104, Push received too late
Description
Push of items was received too late in itemsource arg .
Corresponding wobj already overwritten.
Push scene number arg .
Latest received strobe arg .
Recommended actions
Check the position generation frequency.
111105, Conveyor limits error
Description
Error in itemsource arg
Conveyor arg
6 Trouble shooting by Event log
383
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The limits are incorrect specified.
Recommended actions
Required: Enter < Exit
or: Enter < Start < Stop < Exit
Given: arg
111106, Trig distance warning
Description
Trig distance is too long for conveyor arg .
Trig distance is set to maximum.
Max: arg .
Given: arg .
111107, Trig distance warning
Description
Trig distance is too short for conveyor arg .
Trig distance is set to minimum.
Min: arg
Given: arg .
111108, Failed to send data
Description
An error occured when sending variable arg from the itemsource arg
to remote system.
Status arg .
Recommended actions
Check the position generation frequency and the network connections.
111109, Failed to open signal
Description
An error occured when opening Position Generator signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Position Generator signal name.
111110, Failed to open signal
Description
An error occured when opening Trig signal: arg for itemsource: arg .
Status arg .
Recommended actions
Check the Trig signal name.
111111, Failed to open signal
Description
An error occured when opening Strobe signal: arg for itemsource: arg .
Status arg .
Recommended actions
Check the Strobe signal name.
111112, Failed to open signal
Description
An error occured when opening Robot Execution signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Robot Execution signal name.
111113, Failed to open signal
Description
An error occured when opening Queue Idle signal: arg for itemsource:
arg .
Status arg .
Recommended actions
Check the Queue Idle signal name.
111114, Failed to open signal
Description
An error occured when opening Position Available signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Position Available signal name.
111115, Failed to open signal
Description
An error occured when opening Conveyor Control signal: arg for
itemsource: arg .
Status arg
Recommended actions
Check the Conveyor Control signal name.
111116, Prepared for PickMaster option not
installed.
Description
The Prepared for PickMaster option has not been correctly installed in
the system.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 385
|
6 Trouble shooting by Event log
382
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111013, Cnv data defined late
Description
Error for itemsource arg , conveyor arg . The ItmSrcCnvDat instruction
must be called before the ItmSrcFlush instruction.
arg
Recommended actions
Instruction: arg
Recovery: arg
111014, Timeout
Description
Instruction reached timeout
Recommended actions
Instruction: arg
Recovery: arg
111015, Sortdata overridden
Description
Use of selection data will override the sortdata.
Recommended actions
Instruction: arg
Recovery: arg
111016, Orientation error
Description
The orientation in selection data is not correct defined.
Itemsource: arg
Recommended actions
All used orientations must be normalized i.e. the sum of the quaternion
elements squares must equal 1.
Instruction: arg
Recovery: arg
111017, Uplink message failed
Description
The system failed to send a rapid uplink message
Consequences
Program execution may run as expected.
Statistics may not be updated.
Probable causes
Network interrupt.
CPU overload in controller system.
CPU overload in remote system.
Remote system may not run as expected.
Recommended actions
Check network connection.
Check state of remote system.
Check robot program for infinite loops.
111100, Work object buffer full
Description
Too many conveyor strobes stored in
buffer for itemsource arg
In queue index: arg
Out queue index: arg
111101, Item target buffer full
Description
Item target buffer full for itemsource arg .
Item tag: arg .
Scene number arg .
111102, Too many item targets
Description
Too many item targets pushed to itemsource arg .
Number of items: arg .
Scene number arg .
111103, Push without any strobe
Description
Push received without any corresponding strobe signal is received for
itemsource arg .
Push scene number arg
Latest received strobe arg
Recommended actions
Check hardware connections
111104, Push received too late
Description
Push of items was received too late in itemsource arg .
Corresponding wobj already overwritten.
Push scene number arg .
Latest received strobe arg .
Recommended actions
Check the position generation frequency.
111105, Conveyor limits error
Description
Error in itemsource arg
Conveyor arg
6 Trouble shooting by Event log
383
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The limits are incorrect specified.
Recommended actions
Required: Enter < Exit
or: Enter < Start < Stop < Exit
Given: arg
111106, Trig distance warning
Description
Trig distance is too long for conveyor arg .
Trig distance is set to maximum.
Max: arg .
Given: arg .
111107, Trig distance warning
Description
Trig distance is too short for conveyor arg .
Trig distance is set to minimum.
Min: arg
Given: arg .
111108, Failed to send data
Description
An error occured when sending variable arg from the itemsource arg
to remote system.
Status arg .
Recommended actions
Check the position generation frequency and the network connections.
111109, Failed to open signal
Description
An error occured when opening Position Generator signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Position Generator signal name.
111110, Failed to open signal
Description
An error occured when opening Trig signal: arg for itemsource: arg .
Status arg .
Recommended actions
Check the Trig signal name.
111111, Failed to open signal
Description
An error occured when opening Strobe signal: arg for itemsource: arg .
Status arg .
Recommended actions
Check the Strobe signal name.
111112, Failed to open signal
Description
An error occured when opening Robot Execution signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Robot Execution signal name.
111113, Failed to open signal
Description
An error occured when opening Queue Idle signal: arg for itemsource:
arg .
Status arg .
Recommended actions
Check the Queue Idle signal name.
111114, Failed to open signal
Description
An error occured when opening Position Available signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Position Available signal name.
111115, Failed to open signal
Description
An error occured when opening Conveyor Control signal: arg for
itemsource: arg .
Status arg
Recommended actions
Check the Conveyor Control signal name.
111116, Prepared for PickMaster option not
installed.
Description
The Prepared for PickMaster option has not been correctly installed in
the system.
6 Trouble shooting by Event log
384
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reinstall the system using a proper key containing the Prepared for
PickMaster option.
111117, Uplink message failed
Description
The system failed to send a process uplink message.
Consequences
Item targets may not be picked.
The system may not run as expected.
Probable causes
Network interrupt.
CPU overload in controller system.
CPU overload in remote system.
Remote system may not run as expected.
Recommended actions
Check network connection.
Check state of remote system.
Check robot program for infinite loops.
111400, GAP IO Error
Description
Task: arg
Context: arg
111402, GAP Execution Error
Description
Task: arg
Context: arg
Failed to access routine, arg
111403, Failed to advance to station
Description
Task: arg , failed to advance to station arg
111404, GAP Error
Description
Task: arg ,
GAP Error posted from PartCrossCheckOK routine.
PartCrossCheckOK not ok.
111405, GAP Execution Error
Description
BeforePart or AfterPart Sync Timeout in arg .
111406, Event execution error
Description
Event procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the ee_event data
arg to an existing procedure.
111407, GAP Execution Error
Description
Error in GAPExecCycle: arg
111408, GAP Execution Error
Description
WaitSyncPart Timeout: arg in arg .
111409, GAP Execution Error
Description
Error in GapExecPart: arg .
111410, No part selected for station
Description
No part selected for station arg in task arg .
111411, GAP Execution Error
Description
Part station number is invalid: arg
Valid station: arg
Next station: arg
111412, Not matching tasklists in tasks
Description
Tasklist in partdata arg in task arg does not match tasklist in partdata
arg in task arg .
Recommended actions
Check and change the tasklists so they match.
111413, Invalid task name
Description
Taskname arg in partdata is invalid
111414, GAP Execution Error
Description
The tasklist must include 'this' task: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 386
|
6 Trouble shooting by Event log
383
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
The limits are incorrect specified.
Recommended actions
Required: Enter < Exit
or: Enter < Start < Stop < Exit
Given: arg
111106, Trig distance warning
Description
Trig distance is too long for conveyor arg .
Trig distance is set to maximum.
Max: arg .
Given: arg .
111107, Trig distance warning
Description
Trig distance is too short for conveyor arg .
Trig distance is set to minimum.
Min: arg
Given: arg .
111108, Failed to send data
Description
An error occured when sending variable arg from the itemsource arg
to remote system.
Status arg .
Recommended actions
Check the position generation frequency and the network connections.
111109, Failed to open signal
Description
An error occured when opening Position Generator signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Position Generator signal name.
111110, Failed to open signal
Description
An error occured when opening Trig signal: arg for itemsource: arg .
Status arg .
Recommended actions
Check the Trig signal name.
111111, Failed to open signal
Description
An error occured when opening Strobe signal: arg for itemsource: arg .
Status arg .
Recommended actions
Check the Strobe signal name.
111112, Failed to open signal
Description
An error occured when opening Robot Execution signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Robot Execution signal name.
111113, Failed to open signal
Description
An error occured when opening Queue Idle signal: arg for itemsource:
arg .
Status arg .
Recommended actions
Check the Queue Idle signal name.
111114, Failed to open signal
Description
An error occured when opening Position Available signal: arg for
itemsource: arg .
Status arg .
Recommended actions
Check the Position Available signal name.
111115, Failed to open signal
Description
An error occured when opening Conveyor Control signal: arg for
itemsource: arg .
Status arg
Recommended actions
Check the Conveyor Control signal name.
111116, Prepared for PickMaster option not
installed.
Description
The Prepared for PickMaster option has not been correctly installed in
the system.
6 Trouble shooting by Event log
384
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reinstall the system using a proper key containing the Prepared for
PickMaster option.
111117, Uplink message failed
Description
The system failed to send a process uplink message.
Consequences
Item targets may not be picked.
The system may not run as expected.
Probable causes
Network interrupt.
CPU overload in controller system.
CPU overload in remote system.
Remote system may not run as expected.
Recommended actions
Check network connection.
Check state of remote system.
Check robot program for infinite loops.
111400, GAP IO Error
Description
Task: arg
Context: arg
111402, GAP Execution Error
Description
Task: arg
Context: arg
Failed to access routine, arg
111403, Failed to advance to station
Description
Task: arg , failed to advance to station arg
111404, GAP Error
Description
Task: arg ,
GAP Error posted from PartCrossCheckOK routine.
PartCrossCheckOK not ok.
111405, GAP Execution Error
Description
BeforePart or AfterPart Sync Timeout in arg .
111406, Event execution error
Description
Event procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the ee_event data
arg to an existing procedure.
111407, GAP Execution Error
Description
Error in GAPExecCycle: arg
111408, GAP Execution Error
Description
WaitSyncPart Timeout: arg in arg .
111409, GAP Execution Error
Description
Error in GapExecPart: arg .
111410, No part selected for station
Description
No part selected for station arg in task arg .
111411, GAP Execution Error
Description
Part station number is invalid: arg
Valid station: arg
Next station: arg
111412, Not matching tasklists in tasks
Description
Tasklist in partdata arg in task arg does not match tasklist in partdata
arg in task arg .
Recommended actions
Check and change the tasklists so they match.
111413, Invalid task name
Description
Taskname arg in partdata is invalid
111414, GAP Execution Error
Description
The tasklist must include 'this' task: arg
6 Trouble shooting by Event log
385
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111415, GAP Execution Error
Description
Task: arg
Tasks could not be cross-checked. Station: arg
111416, GAP Execution Error
Description
GapEE_Stopped failed in task: arg
111417, GAP Access IO Error
Description
GAP Access IO Error in task: arg
111419, GAP cfg data error
Description
Cfg data not found in InstancePath: arg
Attribute: arg
111420, GAP IO Error
Description
GAP IO Error in shared module.
111421, GAP Task Error
Description
Maximum of GAP tasks defined ( arg ).
111422, GAP event error
Description
arg GAP_EE_EVT
Unknown event id: arg
111423, GAP proc error
Description
GAP_EE_EVT Unknown proc arg
111424, Partdata not found for PLC code
Description
No matching partdata found in task arg for PLC code arg
Recommended actions
Create partdata with matching plc code.
111425, Menudata not found for PLC code
Description
No matching menudata found in task arg for PLC code arg
Recommended actions
Create menudata with matching plc code.
111426, Not valid task state for menudata
Description
The state of task arg should be at safe or at service when running
selected menudata.
111427, Not valid station for menudata
Description
Current station ( arg ) in task arg does not match valid station arg in
menudata
111428, Not valid user level for menudata
Description
Not valid menudata. Current user level arg does not match minimum
user level arg defined in menudata
111429, Part execution error
Description
Part procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the partdata to an
existing procedure.
111430, Menu execution error
Description
Menu procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the menu to an
existing procedure.
111431, Timeout during handshaking
Description
Timeout during handshaking in task arg .
Probable causes
The configured signal run_part_signal_in or run_menu_signal_in
wasn't set to 0 within configured timeout ( arg seconds) after the
configured signal run_ack_out was set to 1.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 387
|
6 Trouble shooting by Event log
384
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Reinstall the system using a proper key containing the Prepared for
PickMaster option.
111117, Uplink message failed
Description
The system failed to send a process uplink message.
Consequences
Item targets may not be picked.
The system may not run as expected.
Probable causes
Network interrupt.
CPU overload in controller system.
CPU overload in remote system.
Remote system may not run as expected.
Recommended actions
Check network connection.
Check state of remote system.
Check robot program for infinite loops.
111400, GAP IO Error
Description
Task: arg
Context: arg
111402, GAP Execution Error
Description
Task: arg
Context: arg
Failed to access routine, arg
111403, Failed to advance to station
Description
Task: arg , failed to advance to station arg
111404, GAP Error
Description
Task: arg ,
GAP Error posted from PartCrossCheckOK routine.
PartCrossCheckOK not ok.
111405, GAP Execution Error
Description
BeforePart or AfterPart Sync Timeout in arg .
111406, Event execution error
Description
Event procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the ee_event data
arg to an existing procedure.
111407, GAP Execution Error
Description
Error in GAPExecCycle: arg
111408, GAP Execution Error
Description
WaitSyncPart Timeout: arg in arg .
111409, GAP Execution Error
Description
Error in GapExecPart: arg .
111410, No part selected for station
Description
No part selected for station arg in task arg .
111411, GAP Execution Error
Description
Part station number is invalid: arg
Valid station: arg
Next station: arg
111412, Not matching tasklists in tasks
Description
Tasklist in partdata arg in task arg does not match tasklist in partdata
arg in task arg .
Recommended actions
Check and change the tasklists so they match.
111413, Invalid task name
Description
Taskname arg in partdata is invalid
111414, GAP Execution Error
Description
The tasklist must include 'this' task: arg
6 Trouble shooting by Event log
385
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111415, GAP Execution Error
Description
Task: arg
Tasks could not be cross-checked. Station: arg
111416, GAP Execution Error
Description
GapEE_Stopped failed in task: arg
111417, GAP Access IO Error
Description
GAP Access IO Error in task: arg
111419, GAP cfg data error
Description
Cfg data not found in InstancePath: arg
Attribute: arg
111420, GAP IO Error
Description
GAP IO Error in shared module.
111421, GAP Task Error
Description
Maximum of GAP tasks defined ( arg ).
111422, GAP event error
Description
arg GAP_EE_EVT
Unknown event id: arg
111423, GAP proc error
Description
GAP_EE_EVT Unknown proc arg
111424, Partdata not found for PLC code
Description
No matching partdata found in task arg for PLC code arg
Recommended actions
Create partdata with matching plc code.
111425, Menudata not found for PLC code
Description
No matching menudata found in task arg for PLC code arg
Recommended actions
Create menudata with matching plc code.
111426, Not valid task state for menudata
Description
The state of task arg should be at safe or at service when running
selected menudata.
111427, Not valid station for menudata
Description
Current station ( arg ) in task arg does not match valid station arg in
menudata
111428, Not valid user level for menudata
Description
Not valid menudata. Current user level arg does not match minimum
user level arg defined in menudata
111429, Part execution error
Description
Part procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the partdata to an
existing procedure.
111430, Menu execution error
Description
Menu procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the menu to an
existing procedure.
111431, Timeout during handshaking
Description
Timeout during handshaking in task arg .
Probable causes
The configured signal run_part_signal_in or run_menu_signal_in
wasn't set to 0 within configured timeout ( arg seconds) after the
configured signal run_ack_out was set to 1.
6 Trouble shooting by Event log
386
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Make sure to reset configured signal run_part_signal_in or
run_menu_signal_in after configured signal run_ack_out is set to 1.
111432, Not valid plc code in task
Description
Not valid plc code in task arg .
Probable causes
The configured group signal plc_cmd_group_in has a not valid value
arg .
Values in the range of 1-99 is reserved for error codes.
Recommended actions
Make sure requests are higher than 99.
111433, Next station configuration error
Description
PROC configuration for next_stn_ arg _signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure next_stn_ arg _signal_in to ensure that orders for station arg
will be executed.
111434, At station configuration error
Description
PROC configuration for at_stn_ arg _signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure at_stn_ arg _signal_in to ensure that orders for station arg
will be executed.
111501, BullsEye Text Error
Description
BullsEye could not access text.
Index given: arg
Text Table: arg
Consequences
BullsEye will be unable to generate proper message dialogs.
Recommended actions
Please report this error to your ABB support representative.
111502, BullsEye Obsolete Message
Description
BullsEye Obsolete Message
111503, BullsEye Error
Description
Range-of-motion test failed.
111504, BullsEye Error
Description
RangeCheck feature does not support coordinated work objects.
111505, BullsEye Error
Description
RangeCheck feature does not support uframe transforms.
111506, BullsEye Data Loaded
Description
Stored reference data was loaded successfully.
111507, BullsEye Error
Description
No reference data file was found.
Probable causes
No previous data was stored.
111508, BullsEye Error
Description
The reference data file is already loaded.
111509, BullsEye Error
Description
An error occurred while unloading the reference data module.
Recommended actions
Reset program by moving the program pointer to the main routine and
restart program execution.
111510, BullsEye Error
Description
An error occured while reading data from the stored reference data
module.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 388
|
6 Trouble shooting by Event log
385
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111415, GAP Execution Error
Description
Task: arg
Tasks could not be cross-checked. Station: arg
111416, GAP Execution Error
Description
GapEE_Stopped failed in task: arg
111417, GAP Access IO Error
Description
GAP Access IO Error in task: arg
111419, GAP cfg data error
Description
Cfg data not found in InstancePath: arg
Attribute: arg
111420, GAP IO Error
Description
GAP IO Error in shared module.
111421, GAP Task Error
Description
Maximum of GAP tasks defined ( arg ).
111422, GAP event error
Description
arg GAP_EE_EVT
Unknown event id: arg
111423, GAP proc error
Description
GAP_EE_EVT Unknown proc arg
111424, Partdata not found for PLC code
Description
No matching partdata found in task arg for PLC code arg
Recommended actions
Create partdata with matching plc code.
111425, Menudata not found for PLC code
Description
No matching menudata found in task arg for PLC code arg
Recommended actions
Create menudata with matching plc code.
111426, Not valid task state for menudata
Description
The state of task arg should be at safe or at service when running
selected menudata.
111427, Not valid station for menudata
Description
Current station ( arg ) in task arg does not match valid station arg in
menudata
111428, Not valid user level for menudata
Description
Not valid menudata. Current user level arg does not match minimum
user level arg defined in menudata
111429, Part execution error
Description
Part procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the partdata to an
existing procedure.
111430, Menu execution error
Description
Menu procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the menu to an
existing procedure.
111431, Timeout during handshaking
Description
Timeout during handshaking in task arg .
Probable causes
The configured signal run_part_signal_in or run_menu_signal_in
wasn't set to 0 within configured timeout ( arg seconds) after the
configured signal run_ack_out was set to 1.
6 Trouble shooting by Event log
386
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Make sure to reset configured signal run_part_signal_in or
run_menu_signal_in after configured signal run_ack_out is set to 1.
111432, Not valid plc code in task
Description
Not valid plc code in task arg .
Probable causes
The configured group signal plc_cmd_group_in has a not valid value
arg .
Values in the range of 1-99 is reserved for error codes.
Recommended actions
Make sure requests are higher than 99.
111433, Next station configuration error
Description
PROC configuration for next_stn_ arg _signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure next_stn_ arg _signal_in to ensure that orders for station arg
will be executed.
111434, At station configuration error
Description
PROC configuration for at_stn_ arg _signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure at_stn_ arg _signal_in to ensure that orders for station arg
will be executed.
111501, BullsEye Text Error
Description
BullsEye could not access text.
Index given: arg
Text Table: arg
Consequences
BullsEye will be unable to generate proper message dialogs.
Recommended actions
Please report this error to your ABB support representative.
111502, BullsEye Obsolete Message
Description
BullsEye Obsolete Message
111503, BullsEye Error
Description
Range-of-motion test failed.
111504, BullsEye Error
Description
RangeCheck feature does not support coordinated work objects.
111505, BullsEye Error
Description
RangeCheck feature does not support uframe transforms.
111506, BullsEye Data Loaded
Description
Stored reference data was loaded successfully.
111507, BullsEye Error
Description
No reference data file was found.
Probable causes
No previous data was stored.
111508, BullsEye Error
Description
The reference data file is already loaded.
111509, BullsEye Error
Description
An error occurred while unloading the reference data module.
Recommended actions
Reset program by moving the program pointer to the main routine and
restart program execution.
111510, BullsEye Error
Description
An error occured while reading data from the stored reference data
module.
6 Trouble shooting by Event log
387
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111511, BullsEye Data Saved
Description
The reference data has been saved successfully.
111512, BullsEye Error
Description
An error occured while saving the reference data.
111513, BullsEye Tool Initialized
Description
The tool, arg , has been initialized in the BullsEye data collection.
Task: arg
111514, BullsEye Tool Added
Description
The tool, arg , has been added to the BullsEye data collection.
Task: arg
111515, BullsEye Tool Removed
Description
The tool, arg , has been removed from the BullsEye data collection.
Task: arg
Consequences
BullsEye will no longer be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111516, BullsEye IO Error
Description
Invalid input name: arg
Tool: arg
Task: arg
Consequences
No connection to the digital input could be established. Initialization
has failed.
Recommended actions
Check that the specified input exists in the system.
111517, BullsEye Error
Description
The tool, arg , is not included in the BullsEye data collection.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111518, BullsEye IO Error
Description
BullsEye attempted to reconnect a previously connected IO signal.
Input Name: arg
Tool: arg
Task: arg
Recommended actions
If problem persists, run the BESetupToolJ instruction to reinitialize the
tool.
111519, BullsEye RangeCheck Failed
Description
Joint Limit Check failed for a Twist of arg and a Tilt of arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111520, BullsEye RangeCheck Failed
Description
Singularity Check failed for a Twist of arg and a Tilt of arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device.
111521, BullsEye RangeCheck Failed
Description
No solution could be found within acceptable Joint Limits and
Singularity checks.
A Twist of arg and a Tilt of arg was specified.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 389
|
6 Trouble shooting by Event log
386
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Make sure to reset configured signal run_part_signal_in or
run_menu_signal_in after configured signal run_ack_out is set to 1.
111432, Not valid plc code in task
Description
Not valid plc code in task arg .
Probable causes
The configured group signal plc_cmd_group_in has a not valid value
arg .
Values in the range of 1-99 is reserved for error codes.
Recommended actions
Make sure requests are higher than 99.
111433, Next station configuration error
Description
PROC configuration for next_stn_ arg _signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure next_stn_ arg _signal_in to ensure that orders for station arg
will be executed.
111434, At station configuration error
Description
PROC configuration for at_stn_ arg _signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure at_stn_ arg _signal_in to ensure that orders for station arg
will be executed.
111501, BullsEye Text Error
Description
BullsEye could not access text.
Index given: arg
Text Table: arg
Consequences
BullsEye will be unable to generate proper message dialogs.
Recommended actions
Please report this error to your ABB support representative.
111502, BullsEye Obsolete Message
Description
BullsEye Obsolete Message
111503, BullsEye Error
Description
Range-of-motion test failed.
111504, BullsEye Error
Description
RangeCheck feature does not support coordinated work objects.
111505, BullsEye Error
Description
RangeCheck feature does not support uframe transforms.
111506, BullsEye Data Loaded
Description
Stored reference data was loaded successfully.
111507, BullsEye Error
Description
No reference data file was found.
Probable causes
No previous data was stored.
111508, BullsEye Error
Description
The reference data file is already loaded.
111509, BullsEye Error
Description
An error occurred while unloading the reference data module.
Recommended actions
Reset program by moving the program pointer to the main routine and
restart program execution.
111510, BullsEye Error
Description
An error occured while reading data from the stored reference data
module.
6 Trouble shooting by Event log
387
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111511, BullsEye Data Saved
Description
The reference data has been saved successfully.
111512, BullsEye Error
Description
An error occured while saving the reference data.
111513, BullsEye Tool Initialized
Description
The tool, arg , has been initialized in the BullsEye data collection.
Task: arg
111514, BullsEye Tool Added
Description
The tool, arg , has been added to the BullsEye data collection.
Task: arg
111515, BullsEye Tool Removed
Description
The tool, arg , has been removed from the BullsEye data collection.
Task: arg
Consequences
BullsEye will no longer be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111516, BullsEye IO Error
Description
Invalid input name: arg
Tool: arg
Task: arg
Consequences
No connection to the digital input could be established. Initialization
has failed.
Recommended actions
Check that the specified input exists in the system.
111517, BullsEye Error
Description
The tool, arg , is not included in the BullsEye data collection.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111518, BullsEye IO Error
Description
BullsEye attempted to reconnect a previously connected IO signal.
Input Name: arg
Tool: arg
Task: arg
Recommended actions
If problem persists, run the BESetupToolJ instruction to reinitialize the
tool.
111519, BullsEye RangeCheck Failed
Description
Joint Limit Check failed for a Twist of arg and a Tilt of arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111520, BullsEye RangeCheck Failed
Description
Singularity Check failed for a Twist of arg and a Tilt of arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device.
111521, BullsEye RangeCheck Failed
Description
No solution could be found within acceptable Joint Limits and
Singularity checks.
A Twist of arg and a Tilt of arg was specified.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
6 Trouble shooting by Event log
388
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111522, BullsEye RangeCheck Failed
Description
No solution could be found within acceptable Joint Limits and
Singularity checks with adequate face-plate clearance.
A Twist of arg and a Tilt of arg was specified.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111523, BullsEye BaseFrame Read Error
Description
BullsEye was unable to read the BaseFrame definition for the robot.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
The Motion Configuration Database (MOC) may have excessive
protections implemented. Please ensure that the baseframe definition
is accessible.
111524, BullsEye TCP Extended
Description
The instruction, BETcpExtend, was used to shift the TCP of arg .
Task: arg
New Extension: arg
Change: arg
111525, BullsEye Setup Complete
Description
Setup complete for:
Tool: arg
Task: arg
New work object: arg
New TCP: arg
Max, Mean Deviation: arg
111526, BullsEye Setup Failed
Description
The setup for Tool, arg , failed.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
1. Check error log for additional messages.
2. Check setup parameters, sensor device, and start positions before
attempting the setup again.
111527, BullsEye Error
Description
The start position for Tool, arg , is not defined.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to define the position.
111528, BullsEye Beam Moved
Description
Beam has moved or calibration changed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to define the beam
position.
111529, BullsEye Updated TCP
Description
The TCP for Tool, arg , has been updated by BEUpdateTool.
Task: arg
New TCP: arg
Change: arg
Elapsed Time: arg
111530, BullsEye Error
Description
Beam location could not be determined.
Tool: arg
Task: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 390
|
6 Trouble shooting by Event log
387
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111511, BullsEye Data Saved
Description
The reference data has been saved successfully.
111512, BullsEye Error
Description
An error occured while saving the reference data.
111513, BullsEye Tool Initialized
Description
The tool, arg , has been initialized in the BullsEye data collection.
Task: arg
111514, BullsEye Tool Added
Description
The tool, arg , has been added to the BullsEye data collection.
Task: arg
111515, BullsEye Tool Removed
Description
The tool, arg , has been removed from the BullsEye data collection.
Task: arg
Consequences
BullsEye will no longer be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111516, BullsEye IO Error
Description
Invalid input name: arg
Tool: arg
Task: arg
Consequences
No connection to the digital input could be established. Initialization
has failed.
Recommended actions
Check that the specified input exists in the system.
111517, BullsEye Error
Description
The tool, arg , is not included in the BullsEye data collection.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111518, BullsEye IO Error
Description
BullsEye attempted to reconnect a previously connected IO signal.
Input Name: arg
Tool: arg
Task: arg
Recommended actions
If problem persists, run the BESetupToolJ instruction to reinitialize the
tool.
111519, BullsEye RangeCheck Failed
Description
Joint Limit Check failed for a Twist of arg and a Tilt of arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111520, BullsEye RangeCheck Failed
Description
Singularity Check failed for a Twist of arg and a Tilt of arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device.
111521, BullsEye RangeCheck Failed
Description
No solution could be found within acceptable Joint Limits and
Singularity checks.
A Twist of arg and a Tilt of arg was specified.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
6 Trouble shooting by Event log
388
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111522, BullsEye RangeCheck Failed
Description
No solution could be found within acceptable Joint Limits and
Singularity checks with adequate face-plate clearance.
A Twist of arg and a Tilt of arg was specified.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111523, BullsEye BaseFrame Read Error
Description
BullsEye was unable to read the BaseFrame definition for the robot.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
The Motion Configuration Database (MOC) may have excessive
protections implemented. Please ensure that the baseframe definition
is accessible.
111524, BullsEye TCP Extended
Description
The instruction, BETcpExtend, was used to shift the TCP of arg .
Task: arg
New Extension: arg
Change: arg
111525, BullsEye Setup Complete
Description
Setup complete for:
Tool: arg
Task: arg
New work object: arg
New TCP: arg
Max, Mean Deviation: arg
111526, BullsEye Setup Failed
Description
The setup for Tool, arg , failed.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
1. Check error log for additional messages.
2. Check setup parameters, sensor device, and start positions before
attempting the setup again.
111527, BullsEye Error
Description
The start position for Tool, arg , is not defined.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to define the position.
111528, BullsEye Beam Moved
Description
Beam has moved or calibration changed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to define the beam
position.
111529, BullsEye Updated TCP
Description
The TCP for Tool, arg , has been updated by BEUpdateTool.
Task: arg
New TCP: arg
Change: arg
Elapsed Time: arg
111530, BullsEye Error
Description
Beam location could not be determined.
Tool: arg
Task: arg
6 Trouble shooting by Event log
389
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
1. Check that the sensor device is working properly.
2. Execute the BESetupToolJ setup instruction to define the beam
position.
111531, BullsEye Error
Description
The start position was changed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to redefine the new start
position.
111532, BullsEye Error
Description
The tool, arg , is not set up.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111533, BullsEye Error
Description
A full TCP measurement failed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
If problem persists, execute the BESetupToolJ setup instruction to add
and initialize the tool.
111534, BullsEye Day1 TCP Updated
Description
The Day1 TCP has been updated due to a change in the beam location.
Tool: arg
Task: arg
Consequences
New TCP: arg
Change: arg
111535, BullsEye Day1 TCP Updated
Description
The operator has permitted the Day1 TCP to be updated.
Tool: arg
Task: arg
Consequences
New TCP: arg
Change: arg
111536, BullsEye New TCP Rejected
Description
The operator rejected the TCP measurement.
Tool: arg
Task: arg
Consequences
TCP will remain unchanged.
Original TCP: arg
Measured TCP: arg
111537, BullsEye Updated TCP
Description
The TCP for Tool, arg , has been updated by BECheckTcp.
Task: arg
New TCP: arg
Change: arg
Elapsed Time: arg
111538, BullsEye Debug On
Description
Debug mode has been turned on.
Task: arg
111539, BullsEye Debug Off
Description
Debug mode has been turned off.
Task: arg
111540, BullsEye Error
Description
An error has occurred. The cause has not been identified.
Task: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 391
|
6 Trouble shooting by Event log
388
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111522, BullsEye RangeCheck Failed
Description
No solution could be found within acceptable Joint Limits and
Singularity checks with adequate face-plate clearance.
A Twist of arg and a Tilt of arg was specified.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Try a different start position or relocate the BullsEye device. If no
acceptable position can be found, try reducing the requested Tilt and
Twist in the be_scan data. However, be aware that reducing these
values may reduce the accuracy.
111523, BullsEye BaseFrame Read Error
Description
BullsEye was unable to read the BaseFrame definition for the robot.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
The Motion Configuration Database (MOC) may have excessive
protections implemented. Please ensure that the baseframe definition
is accessible.
111524, BullsEye TCP Extended
Description
The instruction, BETcpExtend, was used to shift the TCP of arg .
Task: arg
New Extension: arg
Change: arg
111525, BullsEye Setup Complete
Description
Setup complete for:
Tool: arg
Task: arg
New work object: arg
New TCP: arg
Max, Mean Deviation: arg
111526, BullsEye Setup Failed
Description
The setup for Tool, arg , failed.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
1. Check error log for additional messages.
2. Check setup parameters, sensor device, and start positions before
attempting the setup again.
111527, BullsEye Error
Description
The start position for Tool, arg , is not defined.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to define the position.
111528, BullsEye Beam Moved
Description
Beam has moved or calibration changed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to define the beam
position.
111529, BullsEye Updated TCP
Description
The TCP for Tool, arg , has been updated by BEUpdateTool.
Task: arg
New TCP: arg
Change: arg
Elapsed Time: arg
111530, BullsEye Error
Description
Beam location could not be determined.
Tool: arg
Task: arg
6 Trouble shooting by Event log
389
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
1. Check that the sensor device is working properly.
2. Execute the BESetupToolJ setup instruction to define the beam
position.
111531, BullsEye Error
Description
The start position was changed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to redefine the new start
position.
111532, BullsEye Error
Description
The tool, arg , is not set up.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111533, BullsEye Error
Description
A full TCP measurement failed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
If problem persists, execute the BESetupToolJ setup instruction to add
and initialize the tool.
111534, BullsEye Day1 TCP Updated
Description
The Day1 TCP has been updated due to a change in the beam location.
Tool: arg
Task: arg
Consequences
New TCP: arg
Change: arg
111535, BullsEye Day1 TCP Updated
Description
The operator has permitted the Day1 TCP to be updated.
Tool: arg
Task: arg
Consequences
New TCP: arg
Change: arg
111536, BullsEye New TCP Rejected
Description
The operator rejected the TCP measurement.
Tool: arg
Task: arg
Consequences
TCP will remain unchanged.
Original TCP: arg
Measured TCP: arg
111537, BullsEye Updated TCP
Description
The TCP for Tool, arg , has been updated by BECheckTcp.
Task: arg
New TCP: arg
Change: arg
Elapsed Time: arg
111538, BullsEye Debug On
Description
Debug mode has been turned on.
Task: arg
111539, BullsEye Debug Off
Description
Debug mode has been turned off.
Task: arg
111540, BullsEye Error
Description
An error has occurred. The cause has not been identified.
Task: arg
6 Trouble shooting by Event log
390
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
If problems persists, try:
1. Execute the BESetupToolJ setup instruction to reinitialize the tool.
2. Please contact your ABB support representative if problem cannot
be corrected.
111541, BullsEye TCP OK
Description
The TCP for Tool, arg , has not been updated by BECheckTcp, because
it is within tolerance.
Task: arg
Measured TCP: arg
Current TCP: arg
Elapsed Time: arg
111551, SmarTac Configuration Error
Description
Signal names supplied in PROC cannot be found in EIO.
Recommended actions
Please check the PROC config and EIO config.
111552, SmarTac Configuration Error
Description
An error occurred while attempting to establish connections to I/O.
Recommended actions
Please check the PROC config and EIO config.
111553, SmarTac Configuration Error
Description
SmarTac was unable to find:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111554, SmarTac Configuration Error
Description
SmarTac tried to access an illegal type:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111555, SmarTac Configuration Error
Description
SmarTac experienced an unknown error trying to access:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111556, SmarTac Result
Description
Search Result: arg
Search Type: Search 1D
Search Name: arg
111557, SmarTac Search Override
Description
Optional limit exceeded on Search_1D!
Search Name: arg
The magnitude of the offset = arg
The preset limit = arg
111558, SmarTac Search Override
Description
Default search result selected after failed search.
Manual override selected.
Search Type: Search 1D
Search Name: arg
111559, SmarTac Result
Description
Part detected.
Search Type: Part Search
111560, SmarTac Search Override
Description
Default search result selected.
No part found during part search.
Manual override 'TRUE' selected.
Search Type: Part Search
111561, SmarTac Search Override
Description
Default search result selected.
No part found during part search.
Manual override 'FALSE' selected.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 392
|
6 Trouble shooting by Event log
389
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
1. Check that the sensor device is working properly.
2. Execute the BESetupToolJ setup instruction to define the beam
position.
111531, BullsEye Error
Description
The start position was changed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to redefine the new start
position.
111532, BullsEye Error
Description
The tool, arg , is not set up.
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
Execute the BESetupToolJ setup instruction to add and initialize the
tool.
111533, BullsEye Error
Description
A full TCP measurement failed.
Tool: arg
Task: arg
Consequences
BullsEye will not be able to evaluate this tool.
Recommended actions
If problem persists, execute the BESetupToolJ setup instruction to add
and initialize the tool.
111534, BullsEye Day1 TCP Updated
Description
The Day1 TCP has been updated due to a change in the beam location.
Tool: arg
Task: arg
Consequences
New TCP: arg
Change: arg
111535, BullsEye Day1 TCP Updated
Description
The operator has permitted the Day1 TCP to be updated.
Tool: arg
Task: arg
Consequences
New TCP: arg
Change: arg
111536, BullsEye New TCP Rejected
Description
The operator rejected the TCP measurement.
Tool: arg
Task: arg
Consequences
TCP will remain unchanged.
Original TCP: arg
Measured TCP: arg
111537, BullsEye Updated TCP
Description
The TCP for Tool, arg , has been updated by BECheckTcp.
Task: arg
New TCP: arg
Change: arg
Elapsed Time: arg
111538, BullsEye Debug On
Description
Debug mode has been turned on.
Task: arg
111539, BullsEye Debug Off
Description
Debug mode has been turned off.
Task: arg
111540, BullsEye Error
Description
An error has occurred. The cause has not been identified.
Task: arg
6 Trouble shooting by Event log
390
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
If problems persists, try:
1. Execute the BESetupToolJ setup instruction to reinitialize the tool.
2. Please contact your ABB support representative if problem cannot
be corrected.
111541, BullsEye TCP OK
Description
The TCP for Tool, arg , has not been updated by BECheckTcp, because
it is within tolerance.
Task: arg
Measured TCP: arg
Current TCP: arg
Elapsed Time: arg
111551, SmarTac Configuration Error
Description
Signal names supplied in PROC cannot be found in EIO.
Recommended actions
Please check the PROC config and EIO config.
111552, SmarTac Configuration Error
Description
An error occurred while attempting to establish connections to I/O.
Recommended actions
Please check the PROC config and EIO config.
111553, SmarTac Configuration Error
Description
SmarTac was unable to find:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111554, SmarTac Configuration Error
Description
SmarTac tried to access an illegal type:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111555, SmarTac Configuration Error
Description
SmarTac experienced an unknown error trying to access:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111556, SmarTac Result
Description
Search Result: arg
Search Type: Search 1D
Search Name: arg
111557, SmarTac Search Override
Description
Optional limit exceeded on Search_1D!
Search Name: arg
The magnitude of the offset = arg
The preset limit = arg
111558, SmarTac Search Override
Description
Default search result selected after failed search.
Manual override selected.
Search Type: Search 1D
Search Name: arg
111559, SmarTac Result
Description
Part detected.
Search Type: Part Search
111560, SmarTac Search Override
Description
Default search result selected.
No part found during part search.
Manual override 'TRUE' selected.
Search Type: Part Search
111561, SmarTac Search Override
Description
Default search result selected.
No part found during part search.
Manual override 'FALSE' selected.
6 Trouble shooting by Event log
391
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Search Type: Part Search
111562, SmarTac Result
Description
Location Result: arg
Width Result: arg
Search Type: Groove
Search Name: arg
111563, SmarTac Search Override
Description
Default search result was selected after a failed Groove Search.
Manual override selected.
Search Type: Groove
Search Name: arg
111564, SmarTac Text Error
Description
SmarTac could not access text.
Index given: arg
Text Table: arg
Consequences
SmarTac will not be able to display messages correctly.
Recommended actions
Report to ABB.
111601, DB Table Creation Failed
Description
Failed to create WebWare table: tblBullsEye
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111602, DB Table Created
Description
The table, tblBullsEye, was successfully added to the WebWare
database.
111603, Production Monitor Error
Description
Configuration Error.
Production Monitor was unable to find:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111604, Production Monitor Error
Description
Configuration Error.
Production Monitor tried to access an illegal type:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111605, Production Monitor Error
Description
Configuration Error.
Production Monitor experienced an unknown error trying to access:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111606, Production Monitor Error
Description
Text Resource Error.
Production Monitor could not access text.
Index: arg
File: arg
Recommended actions
Report to ABB.
111607, Production Monitor DB
Description
Creating the tblCycRes table in the WebWare database...
111608, DB Table Creation Failed
Description
Failed to create WebWare table: tblCycRes
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 393
|
6 Trouble shooting by Event log
390
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
If problems persists, try:
1. Execute the BESetupToolJ setup instruction to reinitialize the tool.
2. Please contact your ABB support representative if problem cannot
be corrected.
111541, BullsEye TCP OK
Description
The TCP for Tool, arg , has not been updated by BECheckTcp, because
it is within tolerance.
Task: arg
Measured TCP: arg
Current TCP: arg
Elapsed Time: arg
111551, SmarTac Configuration Error
Description
Signal names supplied in PROC cannot be found in EIO.
Recommended actions
Please check the PROC config and EIO config.
111552, SmarTac Configuration Error
Description
An error occurred while attempting to establish connections to I/O.
Recommended actions
Please check the PROC config and EIO config.
111553, SmarTac Configuration Error
Description
SmarTac was unable to find:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111554, SmarTac Configuration Error
Description
SmarTac tried to access an illegal type:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111555, SmarTac Configuration Error
Description
SmarTac experienced an unknown error trying to access:
arg
in PROC configuration.
Probable causes
A PROC configuration file was loaded with errors.
111556, SmarTac Result
Description
Search Result: arg
Search Type: Search 1D
Search Name: arg
111557, SmarTac Search Override
Description
Optional limit exceeded on Search_1D!
Search Name: arg
The magnitude of the offset = arg
The preset limit = arg
111558, SmarTac Search Override
Description
Default search result selected after failed search.
Manual override selected.
Search Type: Search 1D
Search Name: arg
111559, SmarTac Result
Description
Part detected.
Search Type: Part Search
111560, SmarTac Search Override
Description
Default search result selected.
No part found during part search.
Manual override 'TRUE' selected.
Search Type: Part Search
111561, SmarTac Search Override
Description
Default search result selected.
No part found during part search.
Manual override 'FALSE' selected.
6 Trouble shooting by Event log
391
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Search Type: Part Search
111562, SmarTac Result
Description
Location Result: arg
Width Result: arg
Search Type: Groove
Search Name: arg
111563, SmarTac Search Override
Description
Default search result was selected after a failed Groove Search.
Manual override selected.
Search Type: Groove
Search Name: arg
111564, SmarTac Text Error
Description
SmarTac could not access text.
Index given: arg
Text Table: arg
Consequences
SmarTac will not be able to display messages correctly.
Recommended actions
Report to ABB.
111601, DB Table Creation Failed
Description
Failed to create WebWare table: tblBullsEye
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111602, DB Table Created
Description
The table, tblBullsEye, was successfully added to the WebWare
database.
111603, Production Monitor Error
Description
Configuration Error.
Production Monitor was unable to find:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111604, Production Monitor Error
Description
Configuration Error.
Production Monitor tried to access an illegal type:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111605, Production Monitor Error
Description
Configuration Error.
Production Monitor experienced an unknown error trying to access:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111606, Production Monitor Error
Description
Text Resource Error.
Production Monitor could not access text.
Index: arg
File: arg
Recommended actions
Report to ABB.
111607, Production Monitor DB
Description
Creating the tblCycRes table in the WebWare database...
111608, DB Table Creation Failed
Description
Failed to create WebWare table: tblCycRes
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
6 Trouble shooting by Event log
392
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111609, DB Table Created
Description
The table, tblCycRes, was successfully added to the WebWare
database.
111610, Production Monitor DB
Description
Creating the tblSeamRes table in the WebWare database...
111611, DB Table Creation Failed
Description
Failed to create WebWare table: tblSeamRes
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111612, DB Table Created
Description
The table, tblSeamRes, was successfully added to the WebWare
database.
111613, Production Monitor DB
Description
Creating the tblSeamEv table in the WebWare database...
111614, DB Table Creation Failed
Description
Failed to create WebWare table: tblSeamEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111615, DB Table Created
Description
The table, tblSeamEv, was successfully added to the WebWare
database.
111616, DB Table Creation Failed
Description
Failed to create WebWare table: tblCycleEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111617, DB Table Created
Description
The table, tblCycleEv, was successfully added to the WebWare
database.
111618, DB Table Creation Failed
Description
Failed to create WebWare table: tblGapEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111619, DB Table Created
Description
The table, tblGapEv, was successfully added to the WebWare database.
111620, Production Monitor Mismatch
Description
The part information for, arg , has changed in task, arg .
Consequences
The reference data stored for this part can no longer be linked to the
part program.
Recommended actions
Please delete the reference file to store new data.
111621, Production Monitor Error
Description
The reference data module for part, arg , is already loaded.
An attempt will be made to unload the module and then reload.
Task Name: arg
111622, Production Monitor Error
Description
The reference data module for part, arg , is already loaded. An attempt
to unload the module failed.
Task Name: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 394
|
6 Trouble shooting by Event log
391
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Search Type: Part Search
111562, SmarTac Result
Description
Location Result: arg
Width Result: arg
Search Type: Groove
Search Name: arg
111563, SmarTac Search Override
Description
Default search result was selected after a failed Groove Search.
Manual override selected.
Search Type: Groove
Search Name: arg
111564, SmarTac Text Error
Description
SmarTac could not access text.
Index given: arg
Text Table: arg
Consequences
SmarTac will not be able to display messages correctly.
Recommended actions
Report to ABB.
111601, DB Table Creation Failed
Description
Failed to create WebWare table: tblBullsEye
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111602, DB Table Created
Description
The table, tblBullsEye, was successfully added to the WebWare
database.
111603, Production Monitor Error
Description
Configuration Error.
Production Monitor was unable to find:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111604, Production Monitor Error
Description
Configuration Error.
Production Monitor tried to access an illegal type:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111605, Production Monitor Error
Description
Configuration Error.
Production Monitor experienced an unknown error trying to access:
arg
in the PROC configuration.
Recommended actions
Check the PROC configuration file for errors.
111606, Production Monitor Error
Description
Text Resource Error.
Production Monitor could not access text.
Index: arg
File: arg
Recommended actions
Report to ABB.
111607, Production Monitor DB
Description
Creating the tblCycRes table in the WebWare database...
111608, DB Table Creation Failed
Description
Failed to create WebWare table: tblCycRes
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
6 Trouble shooting by Event log
392
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111609, DB Table Created
Description
The table, tblCycRes, was successfully added to the WebWare
database.
111610, Production Monitor DB
Description
Creating the tblSeamRes table in the WebWare database...
111611, DB Table Creation Failed
Description
Failed to create WebWare table: tblSeamRes
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111612, DB Table Created
Description
The table, tblSeamRes, was successfully added to the WebWare
database.
111613, Production Monitor DB
Description
Creating the tblSeamEv table in the WebWare database...
111614, DB Table Creation Failed
Description
Failed to create WebWare table: tblSeamEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111615, DB Table Created
Description
The table, tblSeamEv, was successfully added to the WebWare
database.
111616, DB Table Creation Failed
Description
Failed to create WebWare table: tblCycleEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111617, DB Table Created
Description
The table, tblCycleEv, was successfully added to the WebWare
database.
111618, DB Table Creation Failed
Description
Failed to create WebWare table: tblGapEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111619, DB Table Created
Description
The table, tblGapEv, was successfully added to the WebWare database.
111620, Production Monitor Mismatch
Description
The part information for, arg , has changed in task, arg .
Consequences
The reference data stored for this part can no longer be linked to the
part program.
Recommended actions
Please delete the reference file to store new data.
111621, Production Monitor Error
Description
The reference data module for part, arg , is already loaded.
An attempt will be made to unload the module and then reload.
Task Name: arg
111622, Production Monitor Error
Description
The reference data module for part, arg , is already loaded. An attempt
to unload the module failed.
Task Name: arg
6 Trouble shooting by Event log
393
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
This is an abnormal condition that will prevent Production Monitor
from working properly until the problem is resolved.
Recommended actions
Delete the reference module from this task and restart program
execution from the main.
111623, Production Monitor Error
Description
The reference data module for part, arg , could not be unloaded.
Task Name: arg
Recommended actions
Restart the program execution from the main.
111624, Production Monitor Error
Description
The reference data for part, arg , could not be read from the stored data
file.
Task Name: arg
Probable causes
The data file may contain syntax errors.
Recommended actions
Please delete the reference data file to allow new data to be stored.
111625, Monitor Data Saved
Description
Nominal data was saved successfully for, arg .
Task Name: arg
111626, Production Monitor Error
Description
An error occured while saving reference data file for part, arg .
Task Name: arg
Consequences
Production Monitor will not be able to perform monitoring activities.
Recommended actions
Report to ABB.
111627, Production Monitor Timer Reset
Description
The cycle timer has been reset to prevent a possible overflow.
Task Name: arg
111628, Production Monitor Timer Reset
Description
The arc timer has been reset to prevent a possible overflow.
Task Name: arg
111629, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtc1D
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111630, DB Table Created
Description
The table, tblSmtc1D, was successfully added to the WebWare
database.
111631, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtcPart
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111632, DB Table Created
Description
The table, tblSmtcPart, was successfully added to the WebWare
database.
111633, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtcGroove
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111634, DB Table Created
Description
The table, tblSmtcGroove, was successfully added to the WebWare
database.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 395
|
6 Trouble shooting by Event log
392
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111609, DB Table Created
Description
The table, tblCycRes, was successfully added to the WebWare
database.
111610, Production Monitor DB
Description
Creating the tblSeamRes table in the WebWare database...
111611, DB Table Creation Failed
Description
Failed to create WebWare table: tblSeamRes
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111612, DB Table Created
Description
The table, tblSeamRes, was successfully added to the WebWare
database.
111613, Production Monitor DB
Description
Creating the tblSeamEv table in the WebWare database...
111614, DB Table Creation Failed
Description
Failed to create WebWare table: tblSeamEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111615, DB Table Created
Description
The table, tblSeamEv, was successfully added to the WebWare
database.
111616, DB Table Creation Failed
Description
Failed to create WebWare table: tblCycleEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111617, DB Table Created
Description
The table, tblCycleEv, was successfully added to the WebWare
database.
111618, DB Table Creation Failed
Description
Failed to create WebWare table: tblGapEv
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111619, DB Table Created
Description
The table, tblGapEv, was successfully added to the WebWare database.
111620, Production Monitor Mismatch
Description
The part information for, arg , has changed in task, arg .
Consequences
The reference data stored for this part can no longer be linked to the
part program.
Recommended actions
Please delete the reference file to store new data.
111621, Production Monitor Error
Description
The reference data module for part, arg , is already loaded.
An attempt will be made to unload the module and then reload.
Task Name: arg
111622, Production Monitor Error
Description
The reference data module for part, arg , is already loaded. An attempt
to unload the module failed.
Task Name: arg
6 Trouble shooting by Event log
393
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
This is an abnormal condition that will prevent Production Monitor
from working properly until the problem is resolved.
Recommended actions
Delete the reference module from this task and restart program
execution from the main.
111623, Production Monitor Error
Description
The reference data module for part, arg , could not be unloaded.
Task Name: arg
Recommended actions
Restart the program execution from the main.
111624, Production Monitor Error
Description
The reference data for part, arg , could not be read from the stored data
file.
Task Name: arg
Probable causes
The data file may contain syntax errors.
Recommended actions
Please delete the reference data file to allow new data to be stored.
111625, Monitor Data Saved
Description
Nominal data was saved successfully for, arg .
Task Name: arg
111626, Production Monitor Error
Description
An error occured while saving reference data file for part, arg .
Task Name: arg
Consequences
Production Monitor will not be able to perform monitoring activities.
Recommended actions
Report to ABB.
111627, Production Monitor Timer Reset
Description
The cycle timer has been reset to prevent a possible overflow.
Task Name: arg
111628, Production Monitor Timer Reset
Description
The arc timer has been reset to prevent a possible overflow.
Task Name: arg
111629, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtc1D
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111630, DB Table Created
Description
The table, tblSmtc1D, was successfully added to the WebWare
database.
111631, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtcPart
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111632, DB Table Created
Description
The table, tblSmtcPart, was successfully added to the WebWare
database.
111633, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtcGroove
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111634, DB Table Created
Description
The table, tblSmtcGroove, was successfully added to the WebWare
database.
6 Trouble shooting by Event log
394
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111635, DB Table Creation Failed
Description
Failed to create WebWare table: tblTchClean
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111636, DB Table Created
Description
The table, tblTchClean, was successfully added to the WebWare
database.
111637, DB Table Creation Failed
Description
Failed to create WebWare table: tblNavigSrchSp.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111638, DB Table Created
Description
The table, tblNavigSrchSp, was successfully added to the WebWare
database.
111639, DB Table Creation Failed
Description
Failed to create WebWare table: tblNavigMeas1D.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111640, DB Table Created
Description
The table, tblNavigMeas1D, was successfully added to the WebWare
database.
111641, DB Table Creation Failed
Description
WebWare database tables must be created in Automatic Mode.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Switch to Automatic Mode and try again.
111701, Torch Services Error
Description
Torch services MechClean configuration error. IO arg NOT found.
111702, Torch Services Error
Description
Torch services MechClean configuration error. Check PROC cfg
domain.
111703, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services was
unable to find: arg / arg in PROC configuration.
111704, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111705, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services
experienced an unknown error trying to access: arg / arg in PROC
configuration.
111706, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services was unable
to find: arg / arg in PROC configuration.
111707, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111708, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services
experienced an unknown error trying to access: arg / arg in PROC
configuration.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 396
|
6 Trouble shooting by Event log
393
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Consequences
This is an abnormal condition that will prevent Production Monitor
from working properly until the problem is resolved.
Recommended actions
Delete the reference module from this task and restart program
execution from the main.
111623, Production Monitor Error
Description
The reference data module for part, arg , could not be unloaded.
Task Name: arg
Recommended actions
Restart the program execution from the main.
111624, Production Monitor Error
Description
The reference data for part, arg , could not be read from the stored data
file.
Task Name: arg
Probable causes
The data file may contain syntax errors.
Recommended actions
Please delete the reference data file to allow new data to be stored.
111625, Monitor Data Saved
Description
Nominal data was saved successfully for, arg .
Task Name: arg
111626, Production Monitor Error
Description
An error occured while saving reference data file for part, arg .
Task Name: arg
Consequences
Production Monitor will not be able to perform monitoring activities.
Recommended actions
Report to ABB.
111627, Production Monitor Timer Reset
Description
The cycle timer has been reset to prevent a possible overflow.
Task Name: arg
111628, Production Monitor Timer Reset
Description
The arc timer has been reset to prevent a possible overflow.
Task Name: arg
111629, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtc1D
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111630, DB Table Created
Description
The table, tblSmtc1D, was successfully added to the WebWare
database.
111631, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtcPart
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111632, DB Table Created
Description
The table, tblSmtcPart, was successfully added to the WebWare
database.
111633, DB Table Creation Failed
Description
Failed to create WebWare table: tblSmtcGroove
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111634, DB Table Created
Description
The table, tblSmtcGroove, was successfully added to the WebWare
database.
6 Trouble shooting by Event log
394
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111635, DB Table Creation Failed
Description
Failed to create WebWare table: tblTchClean
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111636, DB Table Created
Description
The table, tblTchClean, was successfully added to the WebWare
database.
111637, DB Table Creation Failed
Description
Failed to create WebWare table: tblNavigSrchSp.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111638, DB Table Created
Description
The table, tblNavigSrchSp, was successfully added to the WebWare
database.
111639, DB Table Creation Failed
Description
Failed to create WebWare table: tblNavigMeas1D.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111640, DB Table Created
Description
The table, tblNavigMeas1D, was successfully added to the WebWare
database.
111641, DB Table Creation Failed
Description
WebWare database tables must be created in Automatic Mode.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Switch to Automatic Mode and try again.
111701, Torch Services Error
Description
Torch services MechClean configuration error. IO arg NOT found.
111702, Torch Services Error
Description
Torch services MechClean configuration error. Check PROC cfg
domain.
111703, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services was
unable to find: arg / arg in PROC configuration.
111704, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111705, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services
experienced an unknown error trying to access: arg / arg in PROC
configuration.
111706, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services was unable
to find: arg / arg in PROC configuration.
111707, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111708, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services
experienced an unknown error trying to access: arg / arg in PROC
configuration.
6 Trouble shooting by Event log
395
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111709, Torch Services Error
Description
Torch services Wirecut configuration error. IO arg NOT found.
111710, Torch Services Error
Description
Torch services MechClean configuration error. Check PROC cfg
domain.
111711, Torch Services Error
Description
Torch services Spray configuration error. Check PROC cfg domain.
111712, Torch Services Error
Description
Torch services Spray configuration error. Torch Services was unable to
find: arg / arg in PROC configuration.
111713, Torch Services Error
Description
Torch services Spray configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111714, Torch Services Error
Description
Torch services Spray configuration error. Torch Services experienced
an unknown error trying to access: arg / arg in PROC configuration.
111715, Torch Services Warning
Description
Torch services Spray has unconfigured IO.
111716, Torch Services Warning
Description
Torch services Wirecut has unconfigured IO.
111717, Torch Services Warning
Description
Torch services MechClean has unconfigured IO.
111751, Navigator Configuration Error
Description
Navigator configuration error. IO arg NOT found.
111752, Navigator Configuration Error
Description
Navigator configuration error. Navigator was unable to find: arg / arg in
PROC configuration.
111753, Navigator Configuration Error
Description
Navigator configuration error. Navigator tried to access an illegal type:
arg / arg in PROC configuration.
111754, Navigator Configuration Error
Description
Navigator configuration error. Navigator experienced an unknown
error trying to access: arg / arg in PROC configuration.
111755, Navigator error
Description
Sphere with name arg could not be localized.
Probable causes
Nominal point doesn't have sufficient accuracy.
Search radius is too small.
111756, Navigator Configuration Warning
Description
Navigator has unconfigured IO.
111800, Illegal tuning parameter
Description
Task: arg
Context: arg
arg is not a valid tuning parameter.
Arcitune only allows parameters 20 to 29 and 31 to 41.
111801, Illegal Schedule Number
Description
Task: arg
Context: arg
arg is not a valid schedule number.
Arcitune only allows schedules 1 to 99.
111802, Unsupported SID-file version
Description
Task: arg
Context: arg
The SID-file version is not supported.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 397
|
6 Trouble shooting by Event log
394
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111635, DB Table Creation Failed
Description
Failed to create WebWare table: tblTchClean
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111636, DB Table Created
Description
The table, tblTchClean, was successfully added to the WebWare
database.
111637, DB Table Creation Failed
Description
Failed to create WebWare table: tblNavigSrchSp.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111638, DB Table Created
Description
The table, tblNavigSrchSp, was successfully added to the WebWare
database.
111639, DB Table Creation Failed
Description
Failed to create WebWare table: tblNavigMeas1D.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Check the WebWare server.
111640, DB Table Created
Description
The table, tblNavigMeas1D, was successfully added to the WebWare
database.
111641, DB Table Creation Failed
Description
WebWare database tables must be created in Automatic Mode.
Consequences
Production Monitor will be unable to log data to the database.
Recommended actions
Switch to Automatic Mode and try again.
111701, Torch Services Error
Description
Torch services MechClean configuration error. IO arg NOT found.
111702, Torch Services Error
Description
Torch services MechClean configuration error. Check PROC cfg
domain.
111703, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services was
unable to find: arg / arg in PROC configuration.
111704, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111705, Torch Services Error
Description
Torch services MechClean configuration error. Torch Services
experienced an unknown error trying to access: arg / arg in PROC
configuration.
111706, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services was unable
to find: arg / arg in PROC configuration.
111707, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111708, Torch Services Error
Description
Torch services Wirecut configuration error. Torch Services
experienced an unknown error trying to access: arg / arg in PROC
configuration.
6 Trouble shooting by Event log
395
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111709, Torch Services Error
Description
Torch services Wirecut configuration error. IO arg NOT found.
111710, Torch Services Error
Description
Torch services MechClean configuration error. Check PROC cfg
domain.
111711, Torch Services Error
Description
Torch services Spray configuration error. Check PROC cfg domain.
111712, Torch Services Error
Description
Torch services Spray configuration error. Torch Services was unable to
find: arg / arg in PROC configuration.
111713, Torch Services Error
Description
Torch services Spray configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111714, Torch Services Error
Description
Torch services Spray configuration error. Torch Services experienced
an unknown error trying to access: arg / arg in PROC configuration.
111715, Torch Services Warning
Description
Torch services Spray has unconfigured IO.
111716, Torch Services Warning
Description
Torch services Wirecut has unconfigured IO.
111717, Torch Services Warning
Description
Torch services MechClean has unconfigured IO.
111751, Navigator Configuration Error
Description
Navigator configuration error. IO arg NOT found.
111752, Navigator Configuration Error
Description
Navigator configuration error. Navigator was unable to find: arg / arg in
PROC configuration.
111753, Navigator Configuration Error
Description
Navigator configuration error. Navigator tried to access an illegal type:
arg / arg in PROC configuration.
111754, Navigator Configuration Error
Description
Navigator configuration error. Navigator experienced an unknown
error trying to access: arg / arg in PROC configuration.
111755, Navigator error
Description
Sphere with name arg could not be localized.
Probable causes
Nominal point doesn't have sufficient accuracy.
Search radius is too small.
111756, Navigator Configuration Warning
Description
Navigator has unconfigured IO.
111800, Illegal tuning parameter
Description
Task: arg
Context: arg
arg is not a valid tuning parameter.
Arcitune only allows parameters 20 to 29 and 31 to 41.
111801, Illegal Schedule Number
Description
Task: arg
Context: arg
arg is not a valid schedule number.
Arcitune only allows schedules 1 to 99.
111802, Unsupported SID-file version
Description
Task: arg
Context: arg
The SID-file version is not supported.
6 Trouble shooting by Event log
396
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111803, Default I/O Unit is Not Specified
Description
Task: arg
No default io unit specified
InstancePath: /PROC/ARCI_USER_PROP/ arg
Attribute: use_default_io
111804, Configuration Data is Not Found
Description
Task: arg
InstancePath: arg
Attribute: arg
111805, EPROM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111806, RAM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111807, External RAM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111808, Power Supply Voltage 5V Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111809, High DC Voltage Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111810, High Temperature Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111811, High Primary Current Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111812, DC Voltage Error
Description
WDU: 3 V (battery)
PS: +15 VC
I/O unit: arg
Error code: arg
Internal unit: arg
111813, DC Voltage Error
Description
PS: -15 VC
I/O unit: arg
Error code: arg
Internal unit: arg
111814, DC Voltage Error
Description
PS: +15 VB
I/O unit: arg
Error code: arg
Internal unit: arg
111815, Current-servo / Wire speed-servo Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111816, Communication Error
Description
Internal bus warning.
I/O unit: arg
Error code: arg
Internal unit: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 398
|
6 Trouble shooting by Event log
395
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111709, Torch Services Error
Description
Torch services Wirecut configuration error. IO arg NOT found.
111710, Torch Services Error
Description
Torch services MechClean configuration error. Check PROC cfg
domain.
111711, Torch Services Error
Description
Torch services Spray configuration error. Check PROC cfg domain.
111712, Torch Services Error
Description
Torch services Spray configuration error. Torch Services was unable to
find: arg / arg in PROC configuration.
111713, Torch Services Error
Description
Torch services Spray configuration error. Torch Services tried to
access an illegal type: arg / arg in PROC configuration.
111714, Torch Services Error
Description
Torch services Spray configuration error. Torch Services experienced
an unknown error trying to access: arg / arg in PROC configuration.
111715, Torch Services Warning
Description
Torch services Spray has unconfigured IO.
111716, Torch Services Warning
Description
Torch services Wirecut has unconfigured IO.
111717, Torch Services Warning
Description
Torch services MechClean has unconfigured IO.
111751, Navigator Configuration Error
Description
Navigator configuration error. IO arg NOT found.
111752, Navigator Configuration Error
Description
Navigator configuration error. Navigator was unable to find: arg / arg in
PROC configuration.
111753, Navigator Configuration Error
Description
Navigator configuration error. Navigator tried to access an illegal type:
arg / arg in PROC configuration.
111754, Navigator Configuration Error
Description
Navigator configuration error. Navigator experienced an unknown
error trying to access: arg / arg in PROC configuration.
111755, Navigator error
Description
Sphere with name arg could not be localized.
Probable causes
Nominal point doesn't have sufficient accuracy.
Search radius is too small.
111756, Navigator Configuration Warning
Description
Navigator has unconfigured IO.
111800, Illegal tuning parameter
Description
Task: arg
Context: arg
arg is not a valid tuning parameter.
Arcitune only allows parameters 20 to 29 and 31 to 41.
111801, Illegal Schedule Number
Description
Task: arg
Context: arg
arg is not a valid schedule number.
Arcitune only allows schedules 1 to 99.
111802, Unsupported SID-file version
Description
Task: arg
Context: arg
The SID-file version is not supported.
6 Trouble shooting by Event log
396
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111803, Default I/O Unit is Not Specified
Description
Task: arg
No default io unit specified
InstancePath: /PROC/ARCI_USER_PROP/ arg
Attribute: use_default_io
111804, Configuration Data is Not Found
Description
Task: arg
InstancePath: arg
Attribute: arg
111805, EPROM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111806, RAM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111807, External RAM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111808, Power Supply Voltage 5V Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111809, High DC Voltage Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111810, High Temperature Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111811, High Primary Current Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111812, DC Voltage Error
Description
WDU: 3 V (battery)
PS: +15 VC
I/O unit: arg
Error code: arg
Internal unit: arg
111813, DC Voltage Error
Description
PS: -15 VC
I/O unit: arg
Error code: arg
Internal unit: arg
111814, DC Voltage Error
Description
PS: +15 VB
I/O unit: arg
Error code: arg
Internal unit: arg
111815, Current-servo / Wire speed-servo Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111816, Communication Error
Description
Internal bus warning.
I/O unit: arg
Error code: arg
Internal unit: arg
6 Trouble shooting by Event log
397
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111818, Communication Error
Description
Internal bus is off.
I/O unit: arg
Error code: arg
Internal unit: arg
111819, Message Lost
Description
A message has been lost on the internal bus.
I/O unit: arg
Error code: arg
Internal unit: arg
111821, Lost Contact with MEK
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111822, Lost Contact with LUD
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111823, Battery Driven Memory Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111824, Unaccepted Settings
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111825, Incompatible Settings
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111826, Overflow in Transmit Buffer
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111827, Overflow in Receive Buffer
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111829, Incompatible Weld Data Format
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111830, Watchdog Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111832, Stack Overflow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111833, No Water Flow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111834, Lost Contact with TIG Card
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111850, Invalid Tuning Parameter
Description
Task: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 399
|
6 Trouble shooting by Event log
396
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111803, Default I/O Unit is Not Specified
Description
Task: arg
No default io unit specified
InstancePath: /PROC/ARCI_USER_PROP/ arg
Attribute: use_default_io
111804, Configuration Data is Not Found
Description
Task: arg
InstancePath: arg
Attribute: arg
111805, EPROM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111806, RAM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111807, External RAM Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111808, Power Supply Voltage 5V Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111809, High DC Voltage Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111810, High Temperature Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111811, High Primary Current Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111812, DC Voltage Error
Description
WDU: 3 V (battery)
PS: +15 VC
I/O unit: arg
Error code: arg
Internal unit: arg
111813, DC Voltage Error
Description
PS: -15 VC
I/O unit: arg
Error code: arg
Internal unit: arg
111814, DC Voltage Error
Description
PS: +15 VB
I/O unit: arg
Error code: arg
Internal unit: arg
111815, Current-servo / Wire speed-servo Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111816, Communication Error
Description
Internal bus warning.
I/O unit: arg
Error code: arg
Internal unit: arg
6 Trouble shooting by Event log
397
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111818, Communication Error
Description
Internal bus is off.
I/O unit: arg
Error code: arg
Internal unit: arg
111819, Message Lost
Description
A message has been lost on the internal bus.
I/O unit: arg
Error code: arg
Internal unit: arg
111821, Lost Contact with MEK
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111822, Lost Contact with LUD
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111823, Battery Driven Memory Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111824, Unaccepted Settings
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111825, Incompatible Settings
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111826, Overflow in Transmit Buffer
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111827, Overflow in Receive Buffer
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111829, Incompatible Weld Data Format
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111830, Watchdog Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111832, Stack Overflow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111833, No Water Flow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111834, Lost Contact with TIG Card
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111850, Invalid Tuning Parameter
Description
Task: arg
6 Trouble shooting by Event log
398
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Context: arg
arg is not valid as a tuning parameter.
MigRobTune allows parameters 20 to 29 and 31 to 41.
111851, Invalid Schedule Number
Description
Task: arg
Context: arg
arg is not a valid schedule number.
MigRobTune only allows schedules 1 to 99.
111852, Unsupported SID File
Description
Task: arg
Context: arg
The SID file version is not supported.
111853, Default I/O Unit is Not Specified
Description
Task: arg
Default I/O unit is not specified.
InstancePath: /PROC/MIGROB_USER_PROP/ arg
Attribute: use_default_io
111854, Configuration Data is Not Found
Description
Task: arg
InstancePath: arg
Attribute: arg
111855, Schedule does not exist
Description
The schedule arg does not exist in the power source arg , in arg .
Consequences
The welding results will not be as expected.
Recommended actions
Make sure that the schedule has been created before using it in a weld
instruction.
111856, Program memory error (EPROM)
Description
The program memory is damaged in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111857, Microprocessor RAM error
Description
The microprocessor is unable to print/read to the internal memory in
unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111858, External RAM error
Description
The microprocessor is unable to print/read to the external memory in
unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111859, 5V power supply low
Description
The power supply voltage is too low in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process is stopped and starting is prevented.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111860, Intermediate DC voltage outside limits
Description
The voltage is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The power unit is stopped and cannot be started.
Probable causes
Too high a voltage can be due to severe transients on the mains power
supply or to a weak power supply (high inductance of the supply or a
phase missing).
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 400
|
6 Trouble shooting by Event log
397
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111818, Communication Error
Description
Internal bus is off.
I/O unit: arg
Error code: arg
Internal unit: arg
111819, Message Lost
Description
A message has been lost on the internal bus.
I/O unit: arg
Error code: arg
Internal unit: arg
111821, Lost Contact with MEK
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111822, Lost Contact with LUD
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111823, Battery Driven Memory Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111824, Unaccepted Settings
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111825, Incompatible Settings
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111826, Overflow in Transmit Buffer
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111827, Overflow in Receive Buffer
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111829, Incompatible Weld Data Format
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111830, Watchdog Error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111832, Stack Overflow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111833, No Water Flow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111834, Lost Contact with TIG Card
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111850, Invalid Tuning Parameter
Description
Task: arg
6 Trouble shooting by Event log
398
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Context: arg
arg is not valid as a tuning parameter.
MigRobTune allows parameters 20 to 29 and 31 to 41.
111851, Invalid Schedule Number
Description
Task: arg
Context: arg
arg is not a valid schedule number.
MigRobTune only allows schedules 1 to 99.
111852, Unsupported SID File
Description
Task: arg
Context: arg
The SID file version is not supported.
111853, Default I/O Unit is Not Specified
Description
Task: arg
Default I/O unit is not specified.
InstancePath: /PROC/MIGROB_USER_PROP/ arg
Attribute: use_default_io
111854, Configuration Data is Not Found
Description
Task: arg
InstancePath: arg
Attribute: arg
111855, Schedule does not exist
Description
The schedule arg does not exist in the power source arg , in arg .
Consequences
The welding results will not be as expected.
Recommended actions
Make sure that the schedule has been created before using it in a weld
instruction.
111856, Program memory error (EPROM)
Description
The program memory is damaged in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111857, Microprocessor RAM error
Description
The microprocessor is unable to print/read to the internal memory in
unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111858, External RAM error
Description
The microprocessor is unable to print/read to the external memory in
unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111859, 5V power supply low
Description
The power supply voltage is too low in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process is stopped and starting is prevented.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111860, Intermediate DC voltage outside limits
Description
The voltage is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The power unit is stopped and cannot be started.
Probable causes
Too high a voltage can be due to severe transients on the mains power
supply or to a weak power supply (high inductance of the supply or a
phase missing).
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
6 Trouble shooting by Event log
399
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111861, High temperature
Description
The thermal overload-cut has tripped in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process is stopped and cannot be restarted until
the cut-out has reset.
Recommended actions
Check that the cooling air inlets or outlets are not blocked or clogged
with dirt. Check the duty cycle being used, to make sure that the
equipment is not being overloaded.
111862, High primary current
Description
The power unit arg takes too much current from the DC voltage that
supplies it.
Fault code: arg
Internal unit: arg
Consequences
The power unit is stopped and cannot be started.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111863, Low battery voltage or power supply
Description
Unit: arg
See description corresponding to the internal unit: arg
WDU: Low battery voltage +3 V
Battery voltage too low in unit arg . If the battery is not replaced, all
stored data will be lost.
PS: +15 V power supply
The power supply is too high or too low in unit arg .
Fault code: arg
Recommended actions
Send for a service technician.
111864, -15 V power supply
Description
The power supply is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Send for a service technician.
111865, +24 V power supply
Description
The power supply is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Send for a service technician.
111866, Current-servo / wire speed-servo error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111867, Communication error (warning)
Description
The load on the system's CAN-bus is temporarily too high in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The power unit/wire feed unit has lost contact with the welding data
unit.
Recommended actions
Check that all the equipment is correctly connected. If the fault
persists, send for a service technician.
111869, Communication error
Description
The system's CAN-bus has temporarily stopped working due to the
load being too high.
Fault code: arg
Internal unit: arg
Consequences
The current welding process stops.
Recommended actions
Check that all the equipment is correctly connected. Turn off the mains
power supply to reset the unit. If the fault persists, send for a service
technician.
111870, Messages lost
Description
The microprocessor is unable to process incoming messages
sufficiently quickly and information has been lost in unit arg .
Fault code: arg
Internal unit: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 401
|
6 Trouble shooting by Event log
398
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Context: arg
arg is not valid as a tuning parameter.
MigRobTune allows parameters 20 to 29 and 31 to 41.
111851, Invalid Schedule Number
Description
Task: arg
Context: arg
arg is not a valid schedule number.
MigRobTune only allows schedules 1 to 99.
111852, Unsupported SID File
Description
Task: arg
Context: arg
The SID file version is not supported.
111853, Default I/O Unit is Not Specified
Description
Task: arg
Default I/O unit is not specified.
InstancePath: /PROC/MIGROB_USER_PROP/ arg
Attribute: use_default_io
111854, Configuration Data is Not Found
Description
Task: arg
InstancePath: arg
Attribute: arg
111855, Schedule does not exist
Description
The schedule arg does not exist in the power source arg , in arg .
Consequences
The welding results will not be as expected.
Recommended actions
Make sure that the schedule has been created before using it in a weld
instruction.
111856, Program memory error (EPROM)
Description
The program memory is damaged in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111857, Microprocessor RAM error
Description
The microprocessor is unable to print/read to the internal memory in
unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111858, External RAM error
Description
The microprocessor is unable to print/read to the external memory in
unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Restart the machine. If the fault persists, send for a service technician.
111859, 5V power supply low
Description
The power supply voltage is too low in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process is stopped and starting is prevented.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111860, Intermediate DC voltage outside limits
Description
The voltage is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The power unit is stopped and cannot be started.
Probable causes
Too high a voltage can be due to severe transients on the mains power
supply or to a weak power supply (high inductance of the supply or a
phase missing).
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
6 Trouble shooting by Event log
399
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111861, High temperature
Description
The thermal overload-cut has tripped in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process is stopped and cannot be restarted until
the cut-out has reset.
Recommended actions
Check that the cooling air inlets or outlets are not blocked or clogged
with dirt. Check the duty cycle being used, to make sure that the
equipment is not being overloaded.
111862, High primary current
Description
The power unit arg takes too much current from the DC voltage that
supplies it.
Fault code: arg
Internal unit: arg
Consequences
The power unit is stopped and cannot be started.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111863, Low battery voltage or power supply
Description
Unit: arg
See description corresponding to the internal unit: arg
WDU: Low battery voltage +3 V
Battery voltage too low in unit arg . If the battery is not replaced, all
stored data will be lost.
PS: +15 V power supply
The power supply is too high or too low in unit arg .
Fault code: arg
Recommended actions
Send for a service technician.
111864, -15 V power supply
Description
The power supply is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Send for a service technician.
111865, +24 V power supply
Description
The power supply is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Send for a service technician.
111866, Current-servo / wire speed-servo error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111867, Communication error (warning)
Description
The load on the system's CAN-bus is temporarily too high in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The power unit/wire feed unit has lost contact with the welding data
unit.
Recommended actions
Check that all the equipment is correctly connected. If the fault
persists, send for a service technician.
111869, Communication error
Description
The system's CAN-bus has temporarily stopped working due to the
load being too high.
Fault code: arg
Internal unit: arg
Consequences
The current welding process stops.
Recommended actions
Check that all the equipment is correctly connected. Turn off the mains
power supply to reset the unit. If the fault persists, send for a service
technician.
111870, Messages lost
Description
The microprocessor is unable to process incoming messages
sufficiently quickly and information has been lost in unit arg .
Fault code: arg
Internal unit: arg
6 Trouble shooting by Event log
400
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111872, Lost contact with MEK
Description
Unit: arg
Fault code: arg
Internal unit: arg
111873, Lost contact
Description
The welding data unit(WDU) has lost contact with the power unit(PS)
in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process stops.
Recommended actions
Check the cables. If the fault persists, send for a service technician.
111874, Memory error in battery-supplied data
memory RAM
Description
The battery has lost voltage in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. The welding data
unit is reset.
111875, Non-permitted set values stored in
RAM
Description
Non-permitted values have been discovered at start-up in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Delete all data contained in the welding data unit.
Turn off the mains power supply to reset the unit. The welding unit is
reset.
111876, Incompatible set values stored in RAM
Description
Non-permitted welding data combinations have been specified in unit
arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111877, Transmit buffer overflow
Description
The welding data unit does not manage to transmit information to the
other units sufficiently quickly in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit.
111878, Receiver buffer overflow
Description
The welding data unit does not manage to process information from
the other units sufficiently quickly.
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit.
111880, Incompatible weld data format
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111881, Program error
Description
Something has prevented the processor from performing its normal
duties in the program in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The program restarts automatically. The current welding process will
be stopped.
Recommended actions
Review the handling of welding programs during welding. If the fault
is repeated, send for a service technician.
111883, Lost program data
Description
Program execution does not work in unit arg .
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 402
|
6 Trouble shooting by Event log
399
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111861, High temperature
Description
The thermal overload-cut has tripped in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process is stopped and cannot be restarted until
the cut-out has reset.
Recommended actions
Check that the cooling air inlets or outlets are not blocked or clogged
with dirt. Check the duty cycle being used, to make sure that the
equipment is not being overloaded.
111862, High primary current
Description
The power unit arg takes too much current from the DC voltage that
supplies it.
Fault code: arg
Internal unit: arg
Consequences
The power unit is stopped and cannot be started.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111863, Low battery voltage or power supply
Description
Unit: arg
See description corresponding to the internal unit: arg
WDU: Low battery voltage +3 V
Battery voltage too low in unit arg . If the battery is not replaced, all
stored data will be lost.
PS: +15 V power supply
The power supply is too high or too low in unit arg .
Fault code: arg
Recommended actions
Send for a service technician.
111864, -15 V power supply
Description
The power supply is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Send for a service technician.
111865, +24 V power supply
Description
The power supply is too high or too low in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Send for a service technician.
111866, Current-servo / wire speed-servo error
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111867, Communication error (warning)
Description
The load on the system's CAN-bus is temporarily too high in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The power unit/wire feed unit has lost contact with the welding data
unit.
Recommended actions
Check that all the equipment is correctly connected. If the fault
persists, send for a service technician.
111869, Communication error
Description
The system's CAN-bus has temporarily stopped working due to the
load being too high.
Fault code: arg
Internal unit: arg
Consequences
The current welding process stops.
Recommended actions
Check that all the equipment is correctly connected. Turn off the mains
power supply to reset the unit. If the fault persists, send for a service
technician.
111870, Messages lost
Description
The microprocessor is unable to process incoming messages
sufficiently quickly and information has been lost in unit arg .
Fault code: arg
Internal unit: arg
6 Trouble shooting by Event log
400
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111872, Lost contact with MEK
Description
Unit: arg
Fault code: arg
Internal unit: arg
111873, Lost contact
Description
The welding data unit(WDU) has lost contact with the power unit(PS)
in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process stops.
Recommended actions
Check the cables. If the fault persists, send for a service technician.
111874, Memory error in battery-supplied data
memory RAM
Description
The battery has lost voltage in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. The welding data
unit is reset.
111875, Non-permitted set values stored in
RAM
Description
Non-permitted values have been discovered at start-up in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Delete all data contained in the welding data unit.
Turn off the mains power supply to reset the unit. The welding unit is
reset.
111876, Incompatible set values stored in RAM
Description
Non-permitted welding data combinations have been specified in unit
arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111877, Transmit buffer overflow
Description
The welding data unit does not manage to transmit information to the
other units sufficiently quickly in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit.
111878, Receiver buffer overflow
Description
The welding data unit does not manage to process information from
the other units sufficiently quickly.
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit.
111880, Incompatible weld data format
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111881, Program error
Description
Something has prevented the processor from performing its normal
duties in the program in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The program restarts automatically. The current welding process will
be stopped.
Recommended actions
Review the handling of welding programs during welding. If the fault
is repeated, send for a service technician.
111883, Lost program data
Description
Program execution does not work in unit arg .
6 Trouble shooting by Event log
401
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111884, No water flow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111885, Lost contact with TIG card
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111900, Item target buffer full
Description
Target buffer full for Work Area arg .
Target number: arg .
Scene number arg .
111901, Push without any strobe
Description
Push received without any corresponding strobe signal is received for
Work Area arg .
Push scene number arg
Latest received strobe arg
Recommended actions
Check hardware connections
111902, Push received too late
Description
Push of items was received too late to Work Area arg .
Corresponding Work Object already overwritten.
Push scene number arg .
Latest received strobe arg .
Recommended actions
Check the position generation frequency.
111903, Conveyor limits error
Description
Error in Work Area arg
Conveyor arg
The limits are incorrect specified.
Recommended actions
Required: Enter < Exit
or: Enter < Start < Stop < Exit
Given: arg
111904, Trig distance warning
Description
Trig distance is too long for conveyor arg .
Trig distance is set to maximum.
Max: arg .
Given: arg .
111905, Trig distance warning
Description
Trig distance is too short for conveyor arg .
Trig distance is set to minimum.
Min: arg
Given: arg .
111913, Prepared for PickMaster option not
installed.
Description
The Prepared for PickMaster option has not been correctly installed in
the system.
Recommended actions
Reinstall the system using a proper key containing the Prepared for
PickMaster option.
111914, Uplink message failed
Description
The system failed to send an uplink message.
Status: arg
Recommended actions
Check network connection.
Check state of remote system.
111915, Failed to open Work Object
Description
An error occurred when opening Work Object: arg for Work Area: arg .
Status arg .
Consequences
The program execution is immediately halted.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 403
|
6 Trouble shooting by Event log
400
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111872, Lost contact with MEK
Description
Unit: arg
Fault code: arg
Internal unit: arg
111873, Lost contact
Description
The welding data unit(WDU) has lost contact with the power unit(PS)
in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The current welding process stops.
Recommended actions
Check the cables. If the fault persists, send for a service technician.
111874, Memory error in battery-supplied data
memory RAM
Description
The battery has lost voltage in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. The welding data
unit is reset.
111875, Non-permitted set values stored in
RAM
Description
Non-permitted values have been discovered at start-up in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Delete all data contained in the welding data unit.
Turn off the mains power supply to reset the unit. The welding unit is
reset.
111876, Incompatible set values stored in RAM
Description
Non-permitted welding data combinations have been specified in unit
arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111877, Transmit buffer overflow
Description
The welding data unit does not manage to transmit information to the
other units sufficiently quickly in unit arg .
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit.
111878, Receiver buffer overflow
Description
The welding data unit does not manage to process information from
the other units sufficiently quickly.
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit.
111880, Incompatible weld data format
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111881, Program error
Description
Something has prevented the processor from performing its normal
duties in the program in unit arg .
Fault code: arg
Internal unit: arg
Consequences
The program restarts automatically. The current welding process will
be stopped.
Recommended actions
Review the handling of welding programs during welding. If the fault
is repeated, send for a service technician.
111883, Lost program data
Description
Program execution does not work in unit arg .
6 Trouble shooting by Event log
401
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111884, No water flow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111885, Lost contact with TIG card
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111900, Item target buffer full
Description
Target buffer full for Work Area arg .
Target number: arg .
Scene number arg .
111901, Push without any strobe
Description
Push received without any corresponding strobe signal is received for
Work Area arg .
Push scene number arg
Latest received strobe arg
Recommended actions
Check hardware connections
111902, Push received too late
Description
Push of items was received too late to Work Area arg .
Corresponding Work Object already overwritten.
Push scene number arg .
Latest received strobe arg .
Recommended actions
Check the position generation frequency.
111903, Conveyor limits error
Description
Error in Work Area arg
Conveyor arg
The limits are incorrect specified.
Recommended actions
Required: Enter < Exit
or: Enter < Start < Stop < Exit
Given: arg
111904, Trig distance warning
Description
Trig distance is too long for conveyor arg .
Trig distance is set to maximum.
Max: arg .
Given: arg .
111905, Trig distance warning
Description
Trig distance is too short for conveyor arg .
Trig distance is set to minimum.
Min: arg
Given: arg .
111913, Prepared for PickMaster option not
installed.
Description
The Prepared for PickMaster option has not been correctly installed in
the system.
Recommended actions
Reinstall the system using a proper key containing the Prepared for
PickMaster option.
111914, Uplink message failed
Description
The system failed to send an uplink message.
Status: arg
Recommended actions
Check network connection.
Check state of remote system.
111915, Failed to open Work Object
Description
An error occurred when opening Work Object: arg for Work Area: arg .
Status arg .
Consequences
The program execution is immediately halted.
6 Trouble shooting by Event log
402
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
No Work Object arg exist in loaded RAPID modules.
Recommended actions
Check that the Work Object data name exists.
111916, Tool name is missing for target
Description
There was no tool for target in Work Area: arg .
Status arg .
Recommended actions
Check the tool name for target.
111917, Action list name missing
Description
There was no action list name for target in Work Area: arg .
Status arg .
Recommended actions
Check the tool name for target.
111918, Work Object name is missing for Work
Area
Description
There was no Work Object for Work Area: arg .
Status arg .
Recommended actions
Check the Work Object name for Work Area.
111920, Missing tooldata for generated
operation set
Description
Tooldata not found for generated operation set on work area arg .
Consequences
The project can not be run.
Probable causes
Tooldata not properly configured for the robot in the PickMaster line
configuration.
Recommended actions
Check used tooldatas in the PickMaster line configuration.
111921, Target reset after move of Program
Pointer
Description
The current target in work area " arg " with arg products are reset to its
origin and will be executed again.
Consequences
The current target and operation arg from layer arg will be executed
once again.
Probable causes
The PP was moved without any target was finished.
Since the program context cannot be secured, the whole operation will
be executed from beginning.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning.
Restart in reduced speed to avoid unexpected behavior.
111922, Targets lost after move of Program
Pointer
Description
arg targets with arg products in work area " arg " are lost because the
operation was interrupted.
Consequences
The current target and operation arg from layer arg will be lost.
Probable causes
The PP was moved after at least one target in the operation was
finished.
Since the program context cannot be secured, next operation will be
executed.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning. An unfinished operation may be finished
manually.
Restart in reduced speed to avoid unexpected behavior.
111923, Targets lost after LOST acknowledge
Description
arg targets with arg products in Work Area " arg " are lost because the
operation was interrupted.
Consequences
The current target and operation arg from layer arg will be lost.
Probable causes
The last target acknowledge was set to LOST after at least one target
in the operation was finished.
Since the operation cannot be finished, next operation will be
executed.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning. An unfinished operation may be finished
manually.
Restart in reduced speed to avoid unexpected behavior.
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 404
|
6 Trouble shooting by Event log
401
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
111884, No water flow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111885, Lost contact with TIG card
Description
I/O unit: arg
Error code: arg
Internal unit: arg
111900, Item target buffer full
Description
Target buffer full for Work Area arg .
Target number: arg .
Scene number arg .
111901, Push without any strobe
Description
Push received without any corresponding strobe signal is received for
Work Area arg .
Push scene number arg
Latest received strobe arg
Recommended actions
Check hardware connections
111902, Push received too late
Description
Push of items was received too late to Work Area arg .
Corresponding Work Object already overwritten.
Push scene number arg .
Latest received strobe arg .
Recommended actions
Check the position generation frequency.
111903, Conveyor limits error
Description
Error in Work Area arg
Conveyor arg
The limits are incorrect specified.
Recommended actions
Required: Enter < Exit
or: Enter < Start < Stop < Exit
Given: arg
111904, Trig distance warning
Description
Trig distance is too long for conveyor arg .
Trig distance is set to maximum.
Max: arg .
Given: arg .
111905, Trig distance warning
Description
Trig distance is too short for conveyor arg .
Trig distance is set to minimum.
Min: arg
Given: arg .
111913, Prepared for PickMaster option not
installed.
Description
The Prepared for PickMaster option has not been correctly installed in
the system.
Recommended actions
Reinstall the system using a proper key containing the Prepared for
PickMaster option.
111914, Uplink message failed
Description
The system failed to send an uplink message.
Status: arg
Recommended actions
Check network connection.
Check state of remote system.
111915, Failed to open Work Object
Description
An error occurred when opening Work Object: arg for Work Area: arg .
Status arg .
Consequences
The program execution is immediately halted.
6 Trouble shooting by Event log
402
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
No Work Object arg exist in loaded RAPID modules.
Recommended actions
Check that the Work Object data name exists.
111916, Tool name is missing for target
Description
There was no tool for target in Work Area: arg .
Status arg .
Recommended actions
Check the tool name for target.
111917, Action list name missing
Description
There was no action list name for target in Work Area: arg .
Status arg .
Recommended actions
Check the tool name for target.
111918, Work Object name is missing for Work
Area
Description
There was no Work Object for Work Area: arg .
Status arg .
Recommended actions
Check the Work Object name for Work Area.
111920, Missing tooldata for generated
operation set
Description
Tooldata not found for generated operation set on work area arg .
Consequences
The project can not be run.
Probable causes
Tooldata not properly configured for the robot in the PickMaster line
configuration.
Recommended actions
Check used tooldatas in the PickMaster line configuration.
111921, Target reset after move of Program
Pointer
Description
The current target in work area " arg " with arg products are reset to its
origin and will be executed again.
Consequences
The current target and operation arg from layer arg will be executed
once again.
Probable causes
The PP was moved without any target was finished.
Since the program context cannot be secured, the whole operation will
be executed from beginning.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning.
Restart in reduced speed to avoid unexpected behavior.
111922, Targets lost after move of Program
Pointer
Description
arg targets with arg products in work area " arg " are lost because the
operation was interrupted.
Consequences
The current target and operation arg from layer arg will be lost.
Probable causes
The PP was moved after at least one target in the operation was
finished.
Since the program context cannot be secured, next operation will be
executed.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning. An unfinished operation may be finished
manually.
Restart in reduced speed to avoid unexpected behavior.
111923, Targets lost after LOST acknowledge
Description
arg targets with arg products in Work Area " arg " are lost because the
operation was interrupted.
Consequences
The current target and operation arg from layer arg will be lost.
Probable causes
The last target acknowledge was set to LOST after at least one target
in the operation was finished.
Since the operation cannot be finished, next operation will be
executed.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning. An unfinished operation may be finished
manually.
Restart in reduced speed to avoid unexpected behavior.
6 Trouble shooting by Event log
403
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111924, Operation handler not in use
Description
Task: arg
Function arg failed. The current targets in this operation are lost.
Program Ref. arg
Consequences
It is not possible to finish this operation. The execution will stop if no
action is taken in an ERROR handler.
Probable causes
This might be caused by a pulse on the Robot Execution signal after
the operation descriptor has been fetched. It is more likely to occur if
the operation is a multidrop.
Recommended actions
1. Move PP to main and restart the execution.
2. Use an ERROR handler and run i.e. ExitCycle.
Recovery: arg
111925, Failed to open PM work area signal
Description
An error occurred when opening signal arg configured in PickMaster
for work area: arg . (Internal status arg .)
Consequences
The current PickMaster project will not execute.
Probable causes
The work area signal is missing in the I/O configuration of the robot
controller.
The I/O unit is not running.
Recommended actions
1. Check the signal name in the Work Area configuration of
PickMaster.
2. Check the signal name in the I/O configuration of the robot
controller.
3. Check if the I/O unit is running.
111926, Triggering too frequently
Description
A new pulse on signal arg is to be requested before the previous pulse
has finished. The signal is still high. The configured pulse length is arg
ms.
Consequences
The operation fails to complete its task.
Probable causes
The pulse length is too long or the pick and place operation is very
short.
Recommended actions
Decrease the configured pulse length.
111927, PM group signal too short for work area
Description
PickMaster group signal arg configured for work area arg has too few
bits. Required number of bits is arg .
Consequences
The current project can not execute.
Probable causes
The signal has to few bits defined in the I/O configuration of the
controller.
Recommended actions
Check the controller I/O configuration of the signal.
111950, No PickMaster Flow to Retrieve
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Probable causes
There is no flow ready when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction. If a arg is used,
and
this error occur often, increase the arg .
Recovery: arg
111951, Value Error
Description
Task: arg
Illegal value in argument arg .
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
Error in the RAPID program.
Recommended actions
Check the value. arg must be a positive integer.
111952, Execution Error
Description
Task: arg
The task is not allowed to execute the instruction arg .
Program Ref. arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 405
|
6 Trouble shooting by Event log
402
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
No Work Object arg exist in loaded RAPID modules.
Recommended actions
Check that the Work Object data name exists.
111916, Tool name is missing for target
Description
There was no tool for target in Work Area: arg .
Status arg .
Recommended actions
Check the tool name for target.
111917, Action list name missing
Description
There was no action list name for target in Work Area: arg .
Status arg .
Recommended actions
Check the tool name for target.
111918, Work Object name is missing for Work
Area
Description
There was no Work Object for Work Area: arg .
Status arg .
Recommended actions
Check the Work Object name for Work Area.
111920, Missing tooldata for generated
operation set
Description
Tooldata not found for generated operation set on work area arg .
Consequences
The project can not be run.
Probable causes
Tooldata not properly configured for the robot in the PickMaster line
configuration.
Recommended actions
Check used tooldatas in the PickMaster line configuration.
111921, Target reset after move of Program
Pointer
Description
The current target in work area " arg " with arg products are reset to its
origin and will be executed again.
Consequences
The current target and operation arg from layer arg will be executed
once again.
Probable causes
The PP was moved without any target was finished.
Since the program context cannot be secured, the whole operation will
be executed from beginning.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning.
Restart in reduced speed to avoid unexpected behavior.
111922, Targets lost after move of Program
Pointer
Description
arg targets with arg products in work area " arg " are lost because the
operation was interrupted.
Consequences
The current target and operation arg from layer arg will be lost.
Probable causes
The PP was moved after at least one target in the operation was
finished.
Since the program context cannot be secured, next operation will be
executed.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning. An unfinished operation may be finished
manually.
Restart in reduced speed to avoid unexpected behavior.
111923, Targets lost after LOST acknowledge
Description
arg targets with arg products in Work Area " arg " are lost because the
operation was interrupted.
Consequences
The current target and operation arg from layer arg will be lost.
Probable causes
The last target acknowledge was set to LOST after at least one target
in the operation was finished.
Since the operation cannot be finished, next operation will be
executed.
Recommended actions
Make sure the tool is empty and cleared, since the whole cycle will be
executed from beginning. An unfinished operation may be finished
manually.
Restart in reduced speed to avoid unexpected behavior.
6 Trouble shooting by Event log
403
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111924, Operation handler not in use
Description
Task: arg
Function arg failed. The current targets in this operation are lost.
Program Ref. arg
Consequences
It is not possible to finish this operation. The execution will stop if no
action is taken in an ERROR handler.
Probable causes
This might be caused by a pulse on the Robot Execution signal after
the operation descriptor has been fetched. It is more likely to occur if
the operation is a multidrop.
Recommended actions
1. Move PP to main and restart the execution.
2. Use an ERROR handler and run i.e. ExitCycle.
Recovery: arg
111925, Failed to open PM work area signal
Description
An error occurred when opening signal arg configured in PickMaster
for work area: arg . (Internal status arg .)
Consequences
The current PickMaster project will not execute.
Probable causes
The work area signal is missing in the I/O configuration of the robot
controller.
The I/O unit is not running.
Recommended actions
1. Check the signal name in the Work Area configuration of
PickMaster.
2. Check the signal name in the I/O configuration of the robot
controller.
3. Check if the I/O unit is running.
111926, Triggering too frequently
Description
A new pulse on signal arg is to be requested before the previous pulse
has finished. The signal is still high. The configured pulse length is arg
ms.
Consequences
The operation fails to complete its task.
Probable causes
The pulse length is too long or the pick and place operation is very
short.
Recommended actions
Decrease the configured pulse length.
111927, PM group signal too short for work area
Description
PickMaster group signal arg configured for work area arg has too few
bits. Required number of bits is arg .
Consequences
The current project can not execute.
Probable causes
The signal has to few bits defined in the I/O configuration of the
controller.
Recommended actions
Check the controller I/O configuration of the signal.
111950, No PickMaster Flow to Retrieve
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Probable causes
There is no flow ready when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction. If a arg is used,
and
this error occur often, increase the arg .
Recovery: arg
111951, Value Error
Description
Task: arg
Illegal value in argument arg .
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
Error in the RAPID program.
Recommended actions
Check the value. arg must be a positive integer.
111952, Execution Error
Description
Task: arg
The task is not allowed to execute the instruction arg .
Program Ref. arg
6 Trouble shooting by Event log
404
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The task is not configured to control mechanical units
Recommended actions
Change the configuration or remove the instruction.
111953, Can not retrieve operation
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Probable causes
There is no operation to retrieve when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction. If a arg is used,
an this error occur often, increase the arg .
Recovery: arg
111954, Can not retrieve targets
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Probable causes
There is no target ready when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction. If a arg is used,
an this error occur often, increase the arg .
Recovery: arg
111956, Wrong value on in parameter arg
Description
Task: arg
Parameter arg has value arg . The only values that can be used for arg
are the predefined values for:
arg
Program Ref: arg
Consequences
The program execution is immediately halted.
Probable causes
Wrong value on in parameter arg .
Recommended actions
Change value on in parameter arg .
111957, No active project
Description
Task: arg
Instruction/function arg has detected that the project has been stopped.
The RAPID can not continue its execution without an active project.
Program Ref: arg
Consequences
The program execution is immediately halted.
Probable causes
1) Project has been stopped.
2) A power fail has occurred, and the RAPID program has been started
without starting the project again.
3) A warm start has been done, and the RAPID program has been
started without starting the project again.
Recommended actions
Start a project.
In some cases PP must be moved to main.
111958, No active project
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
There is no project running when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction.
Recovery: arg
111959, Not valid work object data
Description
Task: arg
Instruction arg failed.
No Work Area has reference to work object data named arg .
Program Ref. arg
Consequences
The program execution is immediately halted.
Recommended actions
Use an error handler and do a RETRY on instruction with another work
object data as parameter.
Recovery: arg
|
ABB_IRC5_Operating_Troubleshooting_Manual
|
https://library.e.abb.com/public/e6617595547fc6c2c1257cc5004451bd/Operating%20manual_Trouble%20shooting_3HAC020738-001_revK_en.pdf
| 406
|
6 Trouble shooting by Event log
403
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111924, Operation handler not in use
Description
Task: arg
Function arg failed. The current targets in this operation are lost.
Program Ref. arg
Consequences
It is not possible to finish this operation. The execution will stop if no
action is taken in an ERROR handler.
Probable causes
This might be caused by a pulse on the Robot Execution signal after
the operation descriptor has been fetched. It is more likely to occur if
the operation is a multidrop.
Recommended actions
1. Move PP to main and restart the execution.
2. Use an ERROR handler and run i.e. ExitCycle.
Recovery: arg
111925, Failed to open PM work area signal
Description
An error occurred when opening signal arg configured in PickMaster
for work area: arg . (Internal status arg .)
Consequences
The current PickMaster project will not execute.
Probable causes
The work area signal is missing in the I/O configuration of the robot
controller.
The I/O unit is not running.
Recommended actions
1. Check the signal name in the Work Area configuration of
PickMaster.
2. Check the signal name in the I/O configuration of the robot
controller.
3. Check if the I/O unit is running.
111926, Triggering too frequently
Description
A new pulse on signal arg is to be requested before the previous pulse
has finished. The signal is still high. The configured pulse length is arg
ms.
Consequences
The operation fails to complete its task.
Probable causes
The pulse length is too long or the pick and place operation is very
short.
Recommended actions
Decrease the configured pulse length.
111927, PM group signal too short for work area
Description
PickMaster group signal arg configured for work area arg has too few
bits. Required number of bits is arg .
Consequences
The current project can not execute.
Probable causes
The signal has to few bits defined in the I/O configuration of the
controller.
Recommended actions
Check the controller I/O configuration of the signal.
111950, No PickMaster Flow to Retrieve
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Probable causes
There is no flow ready when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction. If a arg is used,
and
this error occur often, increase the arg .
Recovery: arg
111951, Value Error
Description
Task: arg
Illegal value in argument arg .
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
Error in the RAPID program.
Recommended actions
Check the value. arg must be a positive integer.
111952, Execution Error
Description
Task: arg
The task is not allowed to execute the instruction arg .
Program Ref. arg
6 Trouble shooting by Event log
404
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
Probable causes
The task is not configured to control mechanical units
Recommended actions
Change the configuration or remove the instruction.
111953, Can not retrieve operation
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Probable causes
There is no operation to retrieve when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction. If a arg is used,
an this error occur often, increase the arg .
Recovery: arg
111954, Can not retrieve targets
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Probable causes
There is no target ready when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction. If a arg is used,
an this error occur often, increase the arg .
Recovery: arg
111956, Wrong value on in parameter arg
Description
Task: arg
Parameter arg has value arg . The only values that can be used for arg
are the predefined values for:
arg
Program Ref: arg
Consequences
The program execution is immediately halted.
Probable causes
Wrong value on in parameter arg .
Recommended actions
Change value on in parameter arg .
111957, No active project
Description
Task: arg
Instruction/function arg has detected that the project has been stopped.
The RAPID can not continue its execution without an active project.
Program Ref: arg
Consequences
The program execution is immediately halted.
Probable causes
1) Project has been stopped.
2) A power fail has occurred, and the RAPID program has been started
without starting the project again.
3) A warm start has been done, and the RAPID program has been
started without starting the project again.
Recommended actions
Start a project.
In some cases PP must be moved to main.
111958, No active project
Description
Task: arg
Instruction arg failed.
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
There is no project running when executing instruction.
No arg or a low value is used on arg in this instruction.
Recommended actions
Use an error handler and do a RETRY on instruction.
Recovery: arg
111959, Not valid work object data
Description
Task: arg
Instruction arg failed.
No Work Area has reference to work object data named arg .
Program Ref. arg
Consequences
The program execution is immediately halted.
Recommended actions
Use an error handler and do a RETRY on instruction with another work
object data as parameter.
Recovery: arg
6 Trouble shooting by Event log
405
3HAC020738-001 Revision: K
© Copyright 2005-2010 ABB. All rights reserved.
111960, Invalid descriptor used
Description
Task: arg
Instruction arg failed.
The Work Area descriptor that is used refers to an object that does not
exist.
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
An instruction/function is executed without a valid descriptor.
The Work Area descriptor has not been fetched correctly, or it is a
restart after power fail.
Recommended actions
Check manual about how to get valid descriptors for Work Areas.
111961, No PickMaster Flow to Retrieve
Description
Task: arg
Instruction arg failed.
Program Ref. arg
The flow has been deleted when the instruction arg returned the flow.
Consequences
The program execution is immediately halted.
Probable causes
The flow has been removed.
Recommended actions
Restart project.
111962, Invalid target handle
Description
Task: arg
Instruction arg failed.
The target handle that is used refer to an object that does not exist or is
not initialized.
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
An instruction/function is executed without a valid descriptor.
The target handle has not been fetched correctly, or it is a restart after
power fail.
Recommended actions
Restart the project or rewrite the RAPID program.
111963, Invalid action handle
Description
Task: arg
Instruction arg failed.
The action handle that is used refer to an object that does not exist or
is not initialized.
Program Ref. arg
Consequences
The program execution is immediately halted.
Probable causes
An instruction/function is executed without a valid handle.
The action handle has not been fetched correctly, or it is a restart after
power fail.
Recommended actions
Restart the project or rewrite the RAPID program.
111964, Error event trigged
Description
Task: arg
Instruction arg failed.
The Work Area arg is set in error state after an error event.
Program Ref. arg
Consequences
It is not possible to execute the program until the error is solved.
Probable causes
1. The error source signal has set the Work Area in error state.
2. Stop immediately has been used from FlexPendant.
3. An internal process error has occurred.
Recommended actions
Solve the cause of the error situation and use one of the restart options
from FlexPendant
112000, Failed to open signal
Description
An error occurred when opening signal arg for arg .
The signal should be of type arg .
Status arg .
Consequences
The execution is stopped immediately.
Probable causes
Wrong signal type or signal name.
Recommended actions
Check the signal name and type.
|