text stringlengths 78 3.17k |
|---|
<|begin▁of▁sentence|>
### Instruction:
IP_NTP-5-STATE_CHANGE_TO_UNSYNC
### Response:
(Severity: 5), (Category: IP), (Description: when the node state change to unsync with the ntp server.), (Recommended Action: No action is required.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
FT-3-IDPROM_ACCESS_FAILED
### Response:
(Severity: 3), (Category: LIBRARY), (Description: Software cannot read the fan tray's IDRPOM.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support represen... |
<|begin▁of▁sentence|>
### Instruction:
DRP_PAIRING-3-NO_PROC_READY
### Response:
(Severity: 3), (Category: PLATFORM), (Description: Drp_pairing process failed to notify cfgmgr that it is now ready to accept admin config), (Recommended Action: Collect the console error messages exactly as it appears on the console and c... |
<|begin▁of▁sentence|>
### Instruction:
FR_SFRAR-2-INIT
### Response:
(Severity: 2), (Category: L2), (Description: During process start up an unrecoverable error occurred. The component will exit and should be restarted by the System Manager. Once restarted, it should work fine. The performance will be affected in the o... |
<|begin▁of▁sentence|>
### Instruction:
PLAT_L2FIB_VPLS-6-DEBUG_INFO
### Response:
(Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the debugging module in the platform L2FIB VPLS component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.)
<|EOT... |
<|begin▁of▁sentence|>
### Instruction:
BAG_SCHEMA-4-ERR_EVM_CREATE
### Response:
(Severity: 4), (Category: INFRA), (Description: Bag Schema Server failed to create its Event Manager which is a critical resource for the operation of the process. This error may be caused by low memory resources. The process will abort an... |
<|begin▁of▁sentence|>
### Instruction:
ETHER_CTRL-3-IF_OPERATION_FAIL
### Response:
(Severity: 3), (Category: PLATFORM), (Description: The particular operation mentioned in the message failed due to some reason. This is not a critical failure, the process can continue functioning as expected despite the failure.), (Rec... |
<|begin▁of▁sentence|>
### Instruction:
LIBIPV4PROTO-7-GET_PAK_HDR_COUNT
### Response:
(Severity: 7), (Category: IP), (Description: There was a problem while getting total packet header count for this node.), (Recommended Action: This could happen if there is a problem with packet shared memory on the node. The transpor... |
<|begin▁of▁sentence|>
### Instruction:
FPD_SERVER-6-UPGRADE_RESULT
### Response:
(Severity: 6), (Category: INFRA), (Description: Update FPD upgrade Status), (Recommended Action: The reason for failed FPD upgrade to be analyzed. Please contact Cisco Technical)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
XLNC-3-NETLINK_SOCK_HAS_NO_NETNS
### Response:
(Severity: 3), (Category: INFRA), (Description: The Netlink module contains a dictionary which maps each open Netlink socket to a network namespace file descriptor. The module attempted to look up a socket whose file descriptor is not... |
<|begin▁of▁sentence|>
### Instruction:
OBFLMGR-7-RACK_DECODE_FAILURE
### Response:
(Severity: 7), (Category: OS), (Description: An error happened for a rackid decoding.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representati... |
<|begin▁of▁sentence|>
### Instruction:
OIRD-5-OIROUT
### Response:
(Severity: 5), (Category: PLATFORM), (Description: Detected a card is removed from the chassis.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and... |
<|begin▁of▁sentence|>
### Instruction:
TACACSD-3-BAG_ENCODE_ERR
### Response:
(Severity: 3), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative ... |
<|begin▁of▁sentence|>
### Instruction:
EVM-1-QSM
### Response:
(Severity: 1), (Category: OS), (Description: A call to the QSM API failed. The server was not able to advertise itself.), (Recommended Action: This is an internal error and should be reported to TAC. The application process making the call has corrupted dat... |
<|begin▁of▁sentence|>
### Instruction:
FEAT_MGR-3-MATCH_TYPE_IN_ACL_NOT_SUPPORTED
### Response:
(Severity: 3), (Category: PKT_INFRA), (Description: The following match criteria specified in an ACL are not supported as part of a QoS policy: Packet Length, TTL, TCP Flags.), (Recommended Action: remove the match criteria ... |
<|begin▁of▁sentence|>
### Instruction:
INSTHELPER-3-RUNNING_ON_NON_PERSISTENT_DEVICE
### Response:
(Severity: 3), (Category: INSTALL), (Description: A Managed node is running software from a non persistent device when it was instructed to use a persistent device at bring up time. Persistent device not available so soft... |
<|begin▁of▁sentence|>
### Instruction:
CROSSBAR-1-LOW_OUT_MEM_CORR_ECC_ERROR_LNK3
### Response:
(Severity: 1), (Category: PLATFORM), (Description: Crossbar driver detected multicast output memory correctable ECC error on link 3), (Recommended Action: If this alarm persists for a period of 60 seconds after all the cards... |
<|begin▁of▁sentence|>
### Instruction:
RSHD-3-ERR_MALLOC
### Response:
(Severity: 3), (Category: IP), (Description: The server has failed to acquire the required amount of memory), (Recommended Action: Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.)... |
<|begin▁of▁sentence|>
### Instruction:
NVRAM_PLATFORM-4-ERROR_RUN_BMON
### Response:
(Severity: 4), (Category: MEDIA), (Description: pthread_create() returns error. This error occurs when mapping of PLD register for reading NVRAM battery state is failed.), (Recommended Action: No action is required.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
MBSOC-6-BIND_INFO
### Response:
(Severity: 6), (Category: OS), (Description: Print socket bind info.), (Recommended Action: *SUPPORT*)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
XTC-7-CSPF_FALLBACK
### Response:
(Severity: 7), (Category: OS), (Description: A disjoint path couldn't be found.), (Recommended Action: Check network redundancy.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
IPV6_MA-3-EVENT_CONN_FAIL
### Response:
(Severity: 3), (Category: IP), (Description: The IPV6 MA process failed to initialize its event conn mgr infra.), (Recommended Action: Restarting ipv6_ma may fix the issue.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
UCP_OLM-7-ACTIVE_IPCC_AVAIL
### Response:
(Severity: 7), (Category: ROUTING), (Description: An IPCC has come back up or newly configured for a neighbor.), (Recommended Action: No action is required.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
FABRICQ-3-ERR_DEBUG_REGS
### Response:
(Severity: 3), (Category: FABRIC), (Description: Crab debugging registration failure. Its debug infra init failure. May not be related to PD.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system ... |
<|begin▁of▁sentence|>
### Instruction:
PDMA_SPP-3-ERR_THREAD
### Response:
(Severity: 3), (Category: PLATFORM), (Description: PDMA SPP Thread Error message.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provi... |
<|begin▁of▁sentence|>
### Instruction:
ELO-6-UNEXPECTED_STATE
### Response:
(Severity: 6), (Category: L2), (Description: Whilst parsing a variable response packet an invalid state was found. This could be an indication of a faulty implementation on remote peer.), (Recommended Action: No specific IOS-XR action needs to ... |
<|begin▁of▁sentence|>
### Instruction:
IPSEC_SVI_EA-3-STATE_CHANGE
### Response:
(Severity: 3), (Category: SERVICES), (Description: While the IPSec SVI EA process was checking the state for the specified interface, an error was encountered. The interface in question may be left in an inconsistent state.), (Recommended ... |
<|begin▁of▁sentence|>
### Instruction:
IKEv2-6-AUTH_SUCCESS
### Response:
(Severity: 6), (Category: SECURITY), (Description: IKEv2 peer is successfully authenticated using any of the configured remote methods), (Recommended Action: No Action Required)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
PLIM_FPGA-3-ERR_HW_HARD_RESET
### Response:
(Severity: 3), (Category: L2), (Description: A hardware error is detected on the Datapath FPGA. Software will take action as described in the error message to try to recover from the error. The hardware error and the software recovery ac... |
<|begin▁of▁sentence|>
### Instruction:
CPAK-2-LANE_0_LOW_RX_POWER_ALARM
### Response:
(Severity: 2), (Category: PLATFORM), (Description: Environmental monitoring has detected a CPAK Rx power less than or equal to the low Rx power alarm threshold. The CPAK is the pluggable optics on the line cards. The Rx power threshol... |
<|begin▁of▁sentence|>
### Instruction:
BM_PD-6-REPLAY_EVENT
### Response:
(Severity: 6), (Category: L2), (Description: The recent create/update event for the bundle has triggered validation which resulted in BMT misprogramming.This has resulted in replay call for the bundle.), (Recommended Action: Replay event will cor... |
<|begin▁of▁sentence|>
### Instruction:
IPV6_ACL-4-IPACCESSUNSUPPORTED
### Response:
(Severity: 4), (Category: ACL), (Description: An access list that contains object-groups in one of its entries was specified. At this time ACLs with object-groups are supported only for packet filtering. I.e., attached to an interface.)... |
<|begin▁of▁sentence|>
### Instruction:
SPAN-4-DB_DELETE_FAILED
### Response:
(Severity: 4), (Category: L2), (Description: SPAN was unable to remove an object from its database. The process will attempt to recover, but it is possible that traffic will not be replicated correctly, or some traffic will not be replicated t... |
<|begin▁of▁sentence|>
### Instruction:
PLATFORM_LPTS_PIFIB-5-ERR_TCAM_PREFIX_COMPRESS
### Response:
(Severity: 5), (Category: OS), (Description: IPv6 prefix compression failed because the line card has run out of internal resources for compressing a preifx. It shouldn't have any major impact on the system service. The ... |
<|begin▁of▁sentence|>
### Instruction:
BOOTVAR-7-CANT_OPEN
### Response:
(Severity: 7), (Category: INSTALL), (Description: Either the NVRAM file system is in error, or the boot-variable infrastructure is behaving incorrectly. A file required for carrying out the current request or operation could not be opened, so proc... |
<|begin▁of▁sentence|>
### Instruction:
BGP-3-ERR_ALM_ONE_LABEL
### Response:
(Severity: 3), (Category: ROUTING), (Description: The ALM/LSD API was unable to allocate a requested label.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical supp... |
<|begin▁of▁sentence|>
### Instruction:
DMAC-0-CRC_ERROR
### Response:
(Severity: 0), (Category: PLATFORM), (Description: CRC rate above acceptable level), (Recommended Action: Gather the data listed in 'required_info'. If the issue persists then copy the error message exactly as it appears, and report it to your techni... |
<|begin▁of▁sentence|>
### Instruction:
PARSER-7-ERR_LRD_EVENT
### Response:
(Severity: 7), (Category: MGBL), (Description: Registration to LRd failed.), (Recommended Action: Restart parser_server process after all cards come up.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
PLIM-4-SPA_HW_ERR
### Response:
(Severity: 4), (Category: L2), (Description: SPA hardware detected errron on the PLIM. For this no software action is needed.), (Recommended Action: None.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
FIA-1-SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_7_0
### Response:
(Severity: 1), (Category: FABRIC), (Description: SKT_SMC1_INTR_8B10B_DECODE_DISPARITY_ERROR_7 interrupt on FIA), (Recommended Action: Wait a few minutes. If it doesn't recover, please reload the board using command... |
<|begin▁of▁sentence|>
### Instruction:
FABRIC_DRVR-3-ERR_RELOAD
### Response:
(Severity: 3), (Category: FABRIC), (Description: Fabric driver encountered an error when trying to reload. The card cannot be reloaded at the time of the message. Fabric driver may retry again when resources and conditions are met. The card a... |
<|begin▁of▁sentence|>
### Instruction:
CFM-3-SATELLITE_UNEXPECTED_NOTIFICATION
### Response:
(Severity: 3), (Category: L2), (Description: An unexpected notification was received for the given Satellite. CFM may fail to function correctly on the Satellite affected.), (Recommended Action: If the error is the result of a ... |
<|begin▁of▁sentence|>
### Instruction:
VIC-6-BAY_OPTICS_OIRIN
### Response:
(Severity: 6), (Category: PLATFORM), (Description: OPTICS enity is inserted into the line card), (Recommended Action: Debug message only. No action is required.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
IPV6-4-EVENTCONN_CREATE_FAILED
### Response:
(Severity: 4), (Category: IP), (Description: The IPv6 IO process failed to create a connection to a server), (Recommended Action: Restarting ipv6_io may fix the issue.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
ST16550-3-INTERRUPT_UNMASK_ERROR
### Response:
(Severity: 3), (Category: MGBL), (Description: The ST16550 UART driver has been unable to unmask the UART interrupt.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the s... |
<|begin▁of▁sentence|>
### Instruction:
CT_DSP-1-ALARM_OPTICS_PWR_SUPPLY_ALARM
### Response:
(Severity: 1), (Category: PLATFORM), (Description: '.'), (Recommended Action: --)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
BRIDGE-2-XAUI_0_LQ_SEQ_1
### Response:
(Severity: 2), (Category: PLATFORM), (Description: Queue sequence error on XAUI 0 LQ on bridge instance-1.), (Recommended Action: If the error persists, please reload the board using the command 'hw-module location <> reload'. If the message ... |
<|begin▁of▁sentence|>
### Instruction:
FRAG-7-INIT_ERR
### Response:
(Severity: 7), (Category: PKT_INFRA), (Description: The Fragment Reassembly Plugin encountered a fatal error during initialization.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisc... |
<|begin▁of▁sentence|>
### Instruction:
NP-3-NP_PERF_INFO
### Response:
None
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
CPU_CTRL-3-ERR_INIT
### Response:
(Severity: 3), (Category: PLATFORM), (Description: CPUCtrl Driver encountered an initialization error and may not operate correctly. The supplied text string will explain the reason. Call support with this text.), (Recommended Action: Copy the err... |
<|begin▁of▁sentence|>
### Instruction:
IKE-3-INTF_PARAMS_FAILURE
### Response:
(Severity: 3), (Category: SECURITY), (Description: [1] When an interface is configured with a VRF that is not configured globally, it is treated as invalid VRF. SAs should not be created on this interface. [2] When an interface state is not ... |
<|begin▁of▁sentence|>
### Instruction:
STREE-4-CONNECT_FAIL
### Response:
(Severity: 4), (Category: L2), (Description: stp_process is most likely in a bad state or basic system services have failed. stp_process error messages are generally indicative of health of control-ethernet which is critical for system operation.... |
<|begin▁of▁sentence|>
### Instruction:
CLNS-3-EDM_CLIENT
### Response:
(Severity: 3), (Category: ROUTING), (Description: CLNS EDN client (usually a show command) failled to perform certain operation.), (Recommended Action: Please contact cisco-support with required information. Copy the error message exactly as it appe... |
<|begin▁of▁sentence|>
### Instruction:
IP_STATIC-6-NHDB_OUT_OF_SUBNET
### Response:
(Severity: 6), (Category: ROUTING), (Description: The nexthop of a static route is outside of outgoing interface. This is an invalid configuration.), (Recommended Action: Check the routing table to see whether any static routes are miss... |
<|begin▁of▁sentence|>
### Instruction:
DIAMETER_BASE-3-ERR_THREAD_FN
### Response:
(Severity: 3), (Category: SECURITY), (Description: The call to pthread functions, such as pthread_create, lock/unlock a mutex or wait on a condition, failed. The error is displayed in the message.), (Recommended Action: *SH_TECH*)
<|EOT|... |
<|begin▁of▁sentence|>
### Instruction:
FABIO_TOPAZ-3-ERR_QAD_EGRESS_QUEUE_MISSING
### Response:
(Severity: 3), (Category: PLATFORM), (Description: Failed to find the qad queue for egress packets. This could causes applications using this qad queue not sending out packet %s - QAD queue name %s - thread name), (Recommend... |
<|begin▁of▁sentence|>
### Instruction:
ISIS-4-TIMESTAMP_FAIL
### Response:
(Severity: 4), (Category: ROUTING), (Description: An unexpected error occurred whilst recording a timestamp. This implies an internal programming error.), (Recommended Action: Copy the error message exactly as it appears on the console or in the... |
<|begin▁of▁sentence|>
### Instruction:
CATAPULT-3-ERR_EXIT
### Response:
(Severity: 3), (Category: PLATFORM), (Description: An error occurred in CATAPULT Driver which requires exiting (and, hence, restarting) the process.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the ... |
<|begin▁of▁sentence|>
### Instruction:
PLIM_SERVICES-6-SESSION_USAGE_THRESH_EXCEEDED
### Response:
(Severity: 6), (Category: PLATFORM), (Description: Sessions have exceeded 90% threshold Details will be given in the meesage displayed), (Recommended Action: Reduce number of sessions for this particular user.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
SYSDB-7-REPLY
### Response:
(Severity: 7), (Category: SYSDB), (Description: The server failed to reply to a client request. A likely reason for this is that the process in question has exited.), (Recommended Action: Copy the error message exactly as it appears on the console or in... |
<|begin▁of▁sentence|>
### Instruction:
RCMD-4-INV_DIAG_CONFIG
### Response:
(Severity: 4), (Category: ROUTING), (Description: Invalid configuration exists for non-linecard location. Diagnostics configuation can be only for linecard slots.), (Recommended Action: Please remove the invalid location from under RCMD diagnos... |
<|begin▁of▁sentence|>
### Instruction:
RSMLIB-4-EXIT_ON_ERR
### Response:
(Severity: 4), (Category: L2), (Description: An error occurred in the PSE ASIC client library after which the client code cannot continue. This error is encountered when a client module (e.g. cli command) has difficulty retrieving information fro... |
<|begin▁of▁sentence|>
### Instruction:
sIMP-4-ITI_WARN
### Response:
(Severity: 4), (Category: SECURITY), (Description: An internal software error occurred.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provi... |
<|begin▁of▁sentence|>
### Instruction:
I2C-4-BOARD_POWERUP_WARN
### Response:
(Severity: 4), (Category: PLATFORM), (Description: This message is just an warning of different group id in IDEEPROM. Currently this warning can be ignored and continue with the warning.), (Recommended Action: No action required. Ignore this ... |
<|begin▁of▁sentence|>
### Instruction:
PLAT_CLIENT-4-UPGRADE_ALLOWED
### Response:
(Severity: 4), (Category: LICENSE), (Description: Software upgrades are allowed but will be blocked after the upgrade grace period of 90 days expires. Please check show license platform summary/detail for more information.), (Recommended... |
<|begin▁of▁sentence|>
### Instruction:
PLDMGR-3-DEV_LIB_INIT
### Response:
(Severity: 3), (Category: PLATFORM), (Description: An error occurred when loading the PD library for a specific platform's dll for device access, causing the process to return unexpectedly.), (Recommended Action: Copy the error message exactly a... |
<|begin▁of▁sentence|>
### Instruction:
How does IS-IS select the best path to a destination?
### Response:
IS-IS follows this route selection: 1) Prefer L1 path over L2 path, 2) Prefer internal path over external path, 3) Prefer lowest metric, 4) Load balance across up to 6 equal-cost paths.
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
DUMPER-7-THREAD_MUTEX_UNLOCK
### Response:
(Severity: 7), (Category: OS), (Description: A internal mutex operation has failed. This is a bug.), (Recommended Action: Please contact support with the following data. 1. show exception 2. admin show exception trace dumper severity info... |
<|begin▁of▁sentence|>
### Instruction:
ASIC_SCAN_SERVER-3-ERR_INIT
### Response:
(Severity: 3), (Category: L2), (Description: ASIC scan server has failed the initialization sequence due to the specified reason. This would result in the automatic restart of the process.), (Recommended Action: Copy the error message exac... |
<|begin▁of▁sentence|>
### Instruction:
FCA-0-MPA_ACT2_I2C_READ
### Response:
(Severity: 0), (Category: PLATFORM), (Description: i2c failures during LC Authentication), (Recommended Action: Please copy the error message exactly as it appears on the screen and gather the output of CLIs 'show diag <lc> eeprom-info', 'show... |
<|begin▁of▁sentence|>
### Instruction:
POLICY_REPOSITORY_DYNREG-3-INSTALL_AP_FAIL
### Response:
(Severity: 3), (Category: ROUTING), (Description: An error was encountered as new attach point data was being swapped out for old data. As a result, the old data is either still activated, or NO data is activated for this at... |
<|begin▁of▁sentence|>
### Instruction:
IFMGR_ENCAP-3-SYSDB_ERR
### Response:
(Severity: 3), (Category: PKT_INFRA), (Description: The code has hit a sysdb error situation while applying encapsulation config, for which there is no current handling, therefore the system may now be out of sync.), (Recommended Action: Repea... |
<|begin▁of▁sentence|>
### Instruction:
PLACED-3-CARD_TYPE
### Response:
(Severity: 3), (Category: OS), (Description: PlaceD daemon was unable to obtain the card type. Recovery occurs with automatic process restart.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log. ... |
<|begin▁of▁sentence|>
### Instruction:
SSE_QOSEA-6-DEBUG_INIT_FAIL
### Response:
(Severity: 6), (Category: QOS), (Description: Debug initialization failed within EA. Debugs may not be printed), (Recommended Action: Try restarting QoS EA process)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
CCC-4-BOARD_REMOVAL_PWR_OFF
### Response:
(Severity: 4), (Category: DRIVER), (Description: When partially disconnect the card from midplane, the SEATED_L pin will deassert indicating the board removal event, but if the card is left in that position, it will continue receiving powe... |
<|begin▁of▁sentence|>
### Instruction:
FABRIC_DRVR-7-ERRRATE_EXCEED_DEBUG
### Response:
(Severity: 7), (Category: FABRIC), (Description: The fabric driver encountered the annunciated error. The Fabric driver and the System should still continue to function as normal.), (Recommended Action: No action is required.)
<|EOT... |
<|begin▁of▁sentence|>
### Instruction:
PLAT_L2FIB-6-HW_PLAT_INIT_INFO
### Response:
(Severity: 6), (Category: PLATFORM), (Description: Failed to initialize the LC hardware in the platform L2FIB component.), (Recommended Action: No action is required. Platform software will correct itself if this happens.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
PLATFORM_LPTS_PIFIB-3-ERR_PROG_BFD_DISC_TBL
### Response:
(Severity: 3), (Category: OS), (Description: The system failed to program BFD discriminator table on the linecard.), (Recommended Action: When this issue happens, restart the pifibm_server_lc process on that linecard. If th... |
<|begin▁of▁sentence|>
### Instruction:
MFR_MA-3-RECVFROM
### Response:
(Severity: 3), (Category: L2), (Description: The socket call recvfrom returned an error.), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical suppor... |
<|begin▁of▁sentence|>
### Instruction:
LC_CPUCTRL-2-RSP_PAR_ERROR
### Response:
(Severity: 2), (Category: PLATFORM), (Description: LC CPU controller driver detected fabric parity from RSP.), (Recommended Action: If all other LCs also report this parity error alongwith peer RSP, then check for any bent pins on the RSP f... |
<|begin▁of▁sentence|>
### Instruction:
SM-3-CANNOT_DO_DLL
### Response:
(Severity: 3), (Category: INSTALL), (Description: The install infrastructure failed to open/close/reopen a DLL), (Recommended Action: If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your... |
<|begin▁of▁sentence|>
### Instruction:
CIH-1-ASIC_ERROR_PERSIST_REPROG_RESOURCE_THRESH
### Response:
(Severity: 1), (Category: PLATFORM), (Description: ASIC errors need to reprogram resource have happened, such errors has crossed threshold.), (Recommended Action: Errors that cause reprogram resource have happened and e... |
<|begin▁of▁sentence|>
### Instruction:
OSPF-4-SRGB_LIM_EXCEED
### Response:
(Severity: 4), (Category: ROUTING), (Description: Platform does not support the configured segment routing global-block range. This may result in failure in label allocation and affect feature working until it is resolved. Separate errors will ... |
<|begin▁of▁sentence|>
### Instruction:
rlogin-3-ERR_FLUSH
### Response:
(Severity: 3), (Category: IP), (Description: tcflush() call failed.), (Recommended Action: 'Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the represent... |
<|begin▁of▁sentence|>
### Instruction:
AFMON-3-ERR_EVENT_INIT
### Response:
(Severity: 3), (Category: PLATFORM), (Description: Failed to initialize event manager event.), (Recommended Action: No action is required. Process will be automatically restarted. If not recovered, it is a fatal condition If the message recurs,... |
<|begin▁of▁sentence|>
### Instruction:
DPA_QOSEA-3-BANDWIDTH_RANGE
### Response:
(Severity: 3), (Category: QOS), (Description: The minimum bandwidth or shape rate configured is out of the supported bandwidth range at this level. The message will provide further details on the error.), (Recommended Action: Please adjust... |
<|begin▁of▁sentence|>
### Instruction:
SYSDB-4-SC_MISSFILENAME
### Response:
(Severity: 4), (Category: SYSDB), (Description: The command entered requires an file name and one was not supplied.), (Recommended Action: Use the help command to determine the correct usage for this command. If the message recurs, copy the er... |
<|begin▁of▁sentence|>
### Instruction:
What is the purpose of the MPLS TE FRR backup bandwidth protection feature?
### Response:
The MPLS TE FRR backup bandwidth protection feature extends the bandwidth protection concept to backup tunnels. It ensures that backup tunnels configured for bandwidth protection have a bandw... |
<|begin▁of▁sentence|>
### Instruction:
CLKCTRL_T-3-RX_ALARM_RAI_SYNC_0
### Response:
(Severity: 3), (Category: PLATFORM), (Description: The BITS receiver has detected RAI defect for incoming signal. Receiving remote alarm indication(RAI) means the far-end equipment over the T1/E1 line has a problem with the signal it i... |
<|begin▁of▁sentence|>
### Instruction:
FABRIC_DRVR-3-RCC_LIB_INIT_FAIL
### Response:
(Severity: 3), (Category: FABRIC), (Description: Fabric driver cannot initialize the RCC memory controller library. The node may be not be able to initialized properly.), (Recommended Action: Collect all the event logs and 'sh controll... |
<|begin▁of▁sentence|>
### Instruction:
SHELFMGRV2-3-PULSE_FAILURE
### Response:
(Severity: 3), (Category: PLATFORM), (Description: This message indicates that an IPC failure has occured in Shelf Manager.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your C... |
<|begin▁of▁sentence|>
### Instruction:
STP_SHIM-6-LINK_STATE_CHANGE
### Response:
(Severity: 6), (Category: PLATFORM), (Description: Spanning Tree Port's state change indication.), (Recommended Action: No action is required.)
<|EOT|>
|
<|begin▁of▁sentence|>
### Instruction:
PLDMGR-3-MMAP_ERROR
### Response:
(Severity: 3), (Category: PLATFORM), (Description: mmap has failed, this may be a program level error), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support repres... |
<|begin▁of▁sentence|>
### Instruction:
FSYNC-4-TIMER_FAILED
### Response:
(Severity: 4), (Category: L2), (Description: A Frequency Synchronization process has failed to process a timer event.), (Recommended Action: The process will exit and will be restarted. If the problem persists, Copy the error message exactly as i... |
<|begin▁of▁sentence|>
### Instruction:
BGP-3-BUF_TOO_SHORT
### Response:
(Severity: 3), (Category: ROUTING), (Description: Whilst trying to format a string, the buffer passed in was too short and the string was truncated.), (Recommended Action: Copy the error message exactly as it appears on the console or in the syste... |
<|begin▁of▁sentence|>
### Instruction:
STATE_OUT_OF_SYNC-6-UNSUPPORTED_METRIC_ON_BUNDLE_MEMBER
### Response:
(Severity: 6), (Category: PLATFORM), (Description: Some metric types of performance traffic monitoring are not supported on a few types of linecards. User added a new bundle-ethernet member that belongs to a lin... |
<|begin▁of▁sentence|>
### Instruction:
VPA_8P_GE-2-SPA_JKT_ERR
### Response:
(Severity: 2), (Category: L2), (Description: The Jacket failed to parse spa driver arguments.), (Recommended Action: Check if Jacket process is blocked on any thing. collect the trace log via 'show plim ether trace error location <>' 'show pli... |
<|begin▁of▁sentence|>
### Instruction:
SHMWIN_SVR-3-NOVMEM
### Response:
(Severity: 3), (Category: OS), (Description: Not enough memory available for shared memory window in the system. Top shared memory window users will be display on the console.), (Recommended Action: If this message recurs, copy the system message ... |
<|begin▁of▁sentence|>
### Instruction:
TIMER-3-TIMERNEG
### Response:
(Severity: 3), (Category: OS), (Description: An internal error occured in timer api.), (Recommended Action: Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide... |
<|begin▁of▁sentence|>
### Instruction:
SAT_CHASSIS_ENVMON-2-SAT_PEM_NO_INPUT
### Response:
(Severity: 2), (Category: PLATFORM), (Description: This alarm is generated when one of the power cable to power module is unplugged/plugged in on satellite.), (Recommended Action: Please check Power input connections to the satel... |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.