id
stringlengths
12
16
title
stringlengths
6
140
description
stringlengths
76
139k
cpes
listlengths
0
0
cvss_v4_0
null
cvss_v3_1
float64
2.5
10
cvss_v3_0
float64
1.9
10
cvss_v2_0
null
ICSA-21-180-02
Exacq Technologies exacqVision Enterprise Manager
The software does not sufficiently validate, filter, escape, and/or encode user-controllable input before it is placed in output used as a web page, which is served to other users. This may allow an attacker to send malicious requests on behalf of the victim.CVE-2021-27658 has been assigned to this vulnerability. A CVS...
[]
null
null
4.3
null
ICSA-17-285-04A
NXP Semiconductors MQX RTOS (Update A)
The Real-Time TCP/IP Communications Suite (RTCS) in MQX 's DHCP client fails to sanitize all inputs, which may allow maliciously crafted DHCP packets to cause memory to be overwritten, allowing remote code execution.CVE-2017-12718 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; t...
[]
null
null
5.3
null
ICSA-19-183-02
Quest KACE Systems Management Appliance
The vulnerability allows unintentional access to the appliance leveraging functions of the troubleshooting tools located in the administrator user interface. CVE-2019-10973 has been assigned to this vulnerability. A CVSS v3 base score of 2.7 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:...
[]
null
null
2.7
null
ICSMA-18-128-01
Silex Technology SX-500/SD-320AN or GE Healthcare MobileLink (Update B)
Authentication is not verified when making certain POST requests, which may allow attackers to modify system settings.CVE-2018-6020 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L). A system call parameter is not pr...
[]
null
null
7.4
null
ICSA-19-178-01
ABB PB610 Panel Builder 600
The ABB CP635 HMI component implements hidden administrative accounts used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool Panel Builder 600 to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are used over both HTTP(S) and FTP. There ...
[]
null
null
6.5
null
ICSA-22-069-08
Siemens Polarion ALM
A cross-site scripting is present due to improper neutralization of data sent to the web page through the SVN WebClient in the affected product. An attacker could exploit this to execute arbitrary code and extract sensitive information by sending a specially crafted link to users with administrator privileges.
[]
null
6.5
null
null
ICSA-24-030-04
Hitron Systems Security Camera DVR
An improper input validation vulnerability exists in Hitron Systems DVR HVR-4781 versions 1.03 through 4.02 that could allow an attacker to cause network attack in case of using default admin ID/PW. An improper input validation vulnerability exists in Hitron Systems DVR HVR-8781 versions 1.03 through 4.02 that could al...
[]
null
7.4
null
null
ICSA-18-009-01
Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers
The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. CVE-2017-16740 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).
[]
null
null
8.6
null
ICSA-19-290-01
AVEVA Vijeo Citect and Citect SCADA (Update A)
The IEC870IP driver for AVEVA 's Vijeo Citect, Citect SCADA, and Schneider Electric 's Power SCADA Operation has a buffer overflow that could result in a server-side crash. This vulnerability impacts only the IEC870IP driver and not the core Vijeo Citect, Citect SCADA, or Power SCADA Operation software.CVE-2019-13537 h...
[]
null
null
7.5
null
ICSA-20-343-01
Multiple Embedded TCP/IP Stacks
The function used in uIP-Contiki-OS to process IPv6 extension headers and extension header options can be forced into an infinite loop state due to unchecked header/option lengths.CVE-2020-13984 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:...
[]
null
null
8.1
null
ICSA-23-103-09
Siemens SCALANCE XCM332
In libtirpc before 1.3.3rc1, remote attackers could exhaust the file descriptors of a process that uses libtirpc because idle TCP connections are mishandled. This can, in turn, lead to an svc_run infinite loop without accepting new connections. Linux Kernel could allow a local attacker to execute arbitrary code on the ...
[]
null
9.8
null
null
ICSA-24-235-01
Rockwell Automation Emulate3D
A vulnerability exists in Rockwell Automation Emulate3D, which could be leveraged to execute a DLL hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious DLL and perform a remote code execution attack.
[]
null
6.7
null
null
ICSA-22-221-01
Mitsubishi Electric Multiple Factory Automation Products (Update B)
A vulnerability in OpenSSL creates the potential for an infinite loop in the affected product, which could lead to a denial-of-service condition. CVE-2022-0778 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). A vulne...
[]
null
null
9.8
null
ICSA-21-355-04
Emerson DeltaV
A specially crafted script could cause a controller to restart and cause a denial-of-service condition.CVE-2021-26264 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H). Missing DLLs, if replaced by an insider, could ...
[]
null
null
8.1
null
ICSA-21-245-02
JTEKT TOYOPUC Products
The affected product may not be able to properly process an ICMP flood, which may allow an attacker to deny Ethernet communications between affected devices.CVE-2021-33011 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N...
[]
null
null
4.3
null
ICSA-23-299-01
Dingtian DT-R002
relay_cgi.cgi on Dingtian DT-R002 2CH relay devices with firmware 3.1.276A allows an attacker to replay HTTP post requests without the need for authentication or a valid signed/authorized request.
[]
null
5.9
null
null
ICSA-21-294-03
ICONICS GENESIS64 and Mitsubishi Electric MC Works64 OPC UA
The affected products are vulnerable to an uncontrollable recursion, which may trigger a stack-based buffer overflow.CVE-2021-27432 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-22-202-03
Rockwell Automation ISaGRAF Workbench
A crafted malicious .7z exchange file may allow an attacker to gain the privileges of the ISaGRAF Workbench software when opened. If the software is running at the SYSTEM level, then the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.CVE-2022-2463 has been assi...
[]
null
null
8.6
null
ICSA-23-299-02
Centralite Pearl Thermostat
A vulnerability in Centralite Pearl Thermostat 0x04075010 allows attackers to cause a denial of service (DoS) via a crafted Zigbee message.
[]
null
7.5
null
null
ICSMA-22-277-01
BD Totalys MultiProcessor
The affected product uses hard-coded credentials, which could allow an attacker to access, modify, or delete sensitive information including ePHI, PHI, and PII. To exploit this vulnerability, a threat actor would need physical or network access to the system and would need to bypass any additional security controls.CVE...
[]
null
null
6.6
null
ICSMA-21-322-02
Philips Patient Information Center iX (PIC iX) and Efficia CM Series
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. CVE-2021-43548 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculate...
[]
null
null
5.9
null
ICSA-23-047-06
Siemens Simcenter Femap before V2023.1
The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745) The affected application contains an out of bounds write past the end of an alloca...
[]
null
7.8
null
null
ICSA-20-261-01
Advantech WebAccess Node
The affected product has incorrect permissions set for resources used by specific services, which may allow code execution with system privileges.CVE-2020-16202 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-17-234-05
Saia Burgess Controls PCD Controllers
In certain circumstances, the device pads Ethernet frames with memory contents.CVE-2017-9628 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
5.3
null
ICSA-23-187-02
ABUS TVIP
ABUS TVIP 20000-21150 devices allows remote attackers to execute arbitrary code via shell metacharacters in the /cgi-bin/mft/wireless_mft ap field.
[]
null
null
7.2
null
ICSA-21-021-04
Mitsubishi Electric MELFA (Update A)
These robot controllers may allow an attacker to cause a denial-of-service condition in the execution of the robot program and the Ethernet communication by sending many packets in a burst over a short period. As a result of this denial-of-service condition, an error may occurCVE-2021-20586 has been assigned to this vu...
[]
null
null
7.5
null
ICSMA-21-322-02
Philips Patient Information Center iX (PIC iX) and Efficia CM Series
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. CVE-2021-43548 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculate...
[]
null
null
5.9
null
ICSA-18-212-02
Johnson Controls Metasys and BCPro
This vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.CVE-2018-10624 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/...
[]
null
null
4.3
null
ICSA-20-084-02
Schneider Electric IGSS SCADA Software
The affected product could allow a remote unauthenticated attacker to read arbitrary files on the device.CVE-2020-7478 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The affected product could allow a local user ...
[]
null
null
7.8
null
ICSA-22-104-15
Siemens Simcenter Femap
The affected application contains an out of bounds read past the end of an allocated buffer while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15114) The affected application contains an out of bounds write past the end of an allocate...
[]
null
7.8
null
null
ICSA-24-156-01
Uniview NVR301-04S2-P4 (Update A)
The affected product is vulnerable to reflected cross-site scripting attack (XSS). An attacker could send a user a URL that if clicked on could execute malicious JavaScript in their browser. This vulnerability affects both authenticated and unauthenticated pages under the /LAPI/ directory. As session data is unavailabl...
[]
null
6.1
null
null
ICSA-22-349-18
Siemens SCALANCE SC-600 Family
zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches. A use-after-free in Busybox 1.35-x's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function. A malicious server can serve ex...
[]
null
6.5
null
null
ICSA-21-350-17
Siemens JT Utilities and JT Open Toolkit
JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14829) JTTK library in affected products is vulnerable to an out of boun...
[]
null
7.8
null
null
ICSA-19-010-02
Omron CX-One CX-Protocol
Three type confusion vulnerabilities exist when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19027 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector st...
[]
null
null
6.6
null
ICSMA-21-019-01
Philips Interventional Workstations
The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.CVE-2020-27298 has been assigned to this vulnerability. A CV...
[]
null
null
6.5
null
ICSA-23-229-03
Schneider Electric PowerLogic ION7400 / PM8000 / ION8650 / ION8800 / ION9000 Power Meters
A cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.
[]
null
null
8.8
null
ICSA-20-065-01
WAGO I/O-CHECK
A specially crafted packet could cause the server to send back packets containing data from the stack.CVE-2019-5073 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). The affected products are vulnerable to a buffer ...
[]
null
null
10
null
ICSA-19-178-02
ABB CP651 HMI
The ABB CP651 HMI component implements hidden administrative accounts that are used during the provisioning phase of the HMI interface.CVE-2019-10995 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSA-19-178-04
SICK MSC800
The affected firmware versions contain a hard-coded customer account password.CVE-2019-10979 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-22-069-02
Siemens SIMOTICS CONNECT 400
ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004) The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the ...
[]
null
7.5
null
null
ICSA-18-130-01
MatrikonOPC Explorer
Successful exploitation of this vulnerability could allow an attacker to transfer unauthorized files from the host system. The attacker must have local access to be able to exploit this vulnerability.CVE-2018-8714 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector ...
[]
null
null
6.7
null
ICSA-18-172-01
Delta Electronics Delta Industrial Automation COMMGR
The application utilizes a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the applicatio...
[]
null
null
7.3
null
ICSA-18-352-04
3S-Smart Software Solutions GmbH CODESYS V3 Products
The application does not properly restrict communication channels, allowing the source of communication packets to be spoofed. CVE-2018-20026 has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N). The application suffers...
[]
null
null
9.4
null
ICSA-23-096-01
Industrial Control Links ScadaFlex II SCADA Controllers
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 devices, unauthenticated remote attackers can overwrite, delete, or create files. This allows an attacker to execute critical file CRUD operations on the device that can potentially allow system access and impact availability. CVE-2022-25359 has been assigned to this v...
[]
null
null
9.1
null
ICSA-22-326-04
GE CIMPLICITY
The affected product is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiRootOptionTable, which could allow an attacker to execute arbitrary code.CVE-2022-3084 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:...
[]
null
null
7.8
null
ICSA-19-225-01
Delta Industrial Automation DOPSoft
Processing a specially crafted project file may trigger multiple out-of-bounds read vulnerabilities, which may allow information disclosure, remote code execution, or crash of the application.CVE-2019-13513 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string ...
[]
null
null
7.8
null
ICSA-18-233-01
Yokogawa iDefine, STARDOM, ASTPLANNER, and TriFellows
This vulnerability that affects the license management function when it receives specially crafted data. An attacker could overflow the buffer by exploiting this, which may result in the license management function stopping or result in arbitrary code execution.CVE-2018-0651 has been assigned to this vulnerability. A C...
[]
null
null
8.6
null
ICSA-23-255-01
Hitachi Energy Lumada APM Edge
The public API function BIO_new_NDEF is a helper function used for streaming ASN.1 data via a BIO. It is primarily used internally to OpenSSL to support the SMIME, CMS and PKCS7 streaming capabilities, but may also be called directly by end user applications. The function receives a BIO from the caller, prepends a new ...
[]
null
null
5.9
null
ICSA-18-032-02
3S-Smart Software Solutions GmbH CODESYS Web Server
A crafted request may cause a buffer overflow and could therefore execute arbitrary code on the web server or lead to a denial-of-service condition due to a crash in the web server. CVE-2018-5440 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L...
[]
null
null
9.8
null
ICSMA-18-312-01
Philips iSite and IntelliSpace PACS
Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system.CVE-2018-17906 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).
[]
null
null
6.3
null
ICSA-21-182-02
Sensormatic Electronics C-CURE 9000 (Update A)
An insecure client automatic update feature in C-CURE 9000 can allow remote execution of lower privileged Windows programs.CVE-2021-27660 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSA-20-163-02
Rockwell Automation FactoryTalk Linx Software (Update A)
An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.CVE-2020-11999 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is ...
[]
null
null
7.5
null
ICSA-21-061-02
Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers (Update A)
The connection establishment algorithm found in CompactLogix 5370 and ControlLogix 5570 does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in com...
[]
null
null
5.8
null
ICSA-21-350-09
Siemens SINUMERIK Edge
The affected software does not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity by interfering in the communication path between the client and the intended server.
[]
null
7.4
null
null
ICSA-23-052-01
Mitsubishi Electric MELSOFT iQ AppPortal
MELSOFT iQ AppPortal: v1.00A to 1.29F contains a flaw that could result in unidentified impacts such as authentication bypass, information disclosure, or a denial-of-service condition in Apache HTTP Server used by VisualSVN Server. CVE-2023-26377 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has ...
[]
null
null
9.8
null
ICSA-23-348-09
Siemens Simantic S7-1500 CPU family
Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations.
[]
null
7.5
null
null
ICSA-17-192-04
OSIsoft PI Coresight
This product contains a cross-site request forgery vulnerability that may allow access to the PI system.CVE-2017-9641 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L).
[]
null
null
7.1
null
ICSA-17-306-01
Siemens SIMATIC PCS 7 (Update A)
An authenticated, remote attacker who is member of the "administrators" group couldcrash services by sending specially crafted messages to the DCOM interface.
[]
null
null
4.9
null
ICSA-21-315-10
Siemens SENTRON powermanager
The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
[]
null
7.8
null
null
ICSA-22-242-04
Hitachi Energy RTU500 series
A vulnerability exists in the HCI Modbus TCP function included in the affected product versions. If the HCI Modbus TCP is enabled and configured, then an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused...
[]
null
null
7.5
null
ICSA-19-351-02
Siemens SPPA-T3000 (Update A)
Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacke...
[]
null
5.3
null
null
ICSMA-21-152-01
Hillrom Medical Device Management (Update B)
The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution. CVE-2021-27410 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:L). The affected product is vulner...
[]
null
null
5.9
null
ICSA-19-171-01
PHOENIX CONTACT Automation Worx Software Suite
An access of uninitialized pointer vulnerability may allow remote code execution.CVE-2019-12870 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). An out-of-bounds read vulnerability may allow remote code execution.C...
[]
null
null
7.8
null
ICSA-23-171-02
Enphase Installer Toolkit Android App
Enphase Installer Toolkit versions 3.27.0 and prior have hard coded credentials embedded in binary code in the Android application. An attacker can exploit this and gain access to sensitive information.
[]
null
null
8.6
null
ICSA-23-136-02
Rockwell ArmorStart
A cross site scripting vulnerability was discovered that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability. A cross site scripting vulnerability was disco...
[]
null
null
4.7
null
ICSA-19-253-06
OSIsoft PI SQL Client
An attacker could exploit this vulnerability in a third-party component to remotely execute code on the client computer with the same permissions as the PI SQL Client user. Communication with a malicious PI SQL Data Access Server (RTQP Engine) is needed to expose a PI SQL client to this vulnerability.CVE-2017-9765 has ...
[]
null
null
8.1
null
ICSA-23-285-01
Siemens SIMATIC CP products
The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions. Affected devices insufficiently control continuous mapping of direct memory access (DMA) r...
[]
null
4.4
null
null
ICSA-21-112-02
Mitsubishi Electric GOT (Update A)
A password authentication bypass vulnerability exists in the VNC function of the GOT2000 series and the GOT SIMPLE series due to improper authentication.CVE-2021-20590 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N...
[]
null
null
5.9
null
ICSA-24-046-04
Siemens CP343-1 Devices
Affected products incorrectly validate TCP sequence numbers. This could allow an unauthenticated remote attacker to create a denial of service condition by injecting spoofed TCP RST packets.
[]
null
7.5
null
null
ICSA-22-104-04
Siemens SCALANCE FragAttacks
The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary c...
[]
null
5.4
null
null
ICSA-20-310-02
Mitsubishi Electric GT14 Model of GOT1000 Series
The affected product has a memory corruption vulnerability, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.CVE-2020-5644 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is ...
[]
null
null
5.3
null
ICSA-22-144-02
Matrikon OPC Server
The affected product is vulnerable to a condition where a low-privileged user allowed to connect to the OPC server to use the functions of the IPersisFile can execute operating system processes with system-level privileges.CVE-2022-1261 has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been assig...
[]
null
null
5.8
null
ICSA-21-210-01
Hitachi ABB Power Grids eSOMS
The web application password field allows a browser to store user credentials, which may allow an attacker who gains control of the users ' system, or successfully exploits a cross site scripting vulnerability in another application, to capture stored passwords.CVE-2021-35527 has been assigned to this vulnerability. A ...
[]
null
null
7.5
null
ICSA-23-334-01
Delta Electronics DOPSoft
The affected product is vulnerable to a stack-based buffer overflow, which may allow for arbitrary code execution if an attacker can lead a legitimate user to execute a specially crafted file.
[]
null
null
7.8
null
ICSA-22-172-01
Mitsubishi Electric MELSEC iQ-R, Q, L Series and MELIPC Series (Update B)
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
[]
null
null
7.5
null
ICSA-19-318-01
Siemens Mentor Nucleus Networking Module
By sending specially crafted DHCP packets to a device, an attacker may be able to affect availability and integrity of the device. Adjacent network access, but no authentication and no user interaction is needed to conduct this attack. At the time of advisory publication no public exploitation of this security vulnerab...
[]
null
null
7.1
null
ICSA-20-014-01
GE PACSystems RX3i
Sending specially manipulated packets can cause the module state to change to halt-mode, resulting in a denial-of-service condition. An operator must reboot the CPU module after removing battery or energy pack to recover from halt-mode.CVE-2019-13524 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 ...
[]
null
null
7.5
null
ICSA-23-264-05
Rockwell Automation Connected Components Workbench
Connected Components Workbench utilizes CefSharp version 81.3.100 that contains a use after free vulnerability in Google Chrome versions before 86.0.4240.198. If exploited, a remote threat actor could potentially perform a sandbox escape via a crafted HTML page. Connected Components Workbench utilizes CefSharp version ...
[]
null
null
8.8
null
ICSA-22-258-02
Siemens Simcenter Femap and Parasolid
The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17276) The affected application contains an out of bounds write past the end of an al...
[]
null
7.8
null
null
ICSA-23-026-02
Econolite EOS (Update A)
Econolite EOS versions prior to 3.2.23 lack a password requirement for gaining "READONLY" access to log files and certain database and configuration files. One such file contains tables with MD5 hashes and usernames for all defined users in the control software, including administrators and technicians. Econolite EOS v...
[]
null
9.8
null
null
ICSA-21-028-01
Rockwell Automation FactoryTalk Linx and FactoryTalk Services Platform
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected. An attacker-control...
[]
null
null
7.5
null
ICSA-21-103-03
JTEKT TOYOPUC products
If Ethernet communication of the affected product is left in an open state by an attacker, Ethernet communications cannot be established with other devices, depending on the settings of the link parameters.CVE-2021-27458 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS ...
[]
null
null
7.5
null
ICSA-21-110-01
Hitachi ABB Power Grids Ellipse APM
A stored XSS vulnerability in the main dashboard of Ellipse APM versions prior to 5.3.0.1, 5.2.0.3, and 5.1.0.6 allows an authenticated user or integrated application to inject malicious data into the application that can then be executed in a victim 's browser.CVE-2021-27887 has been assigned to this vulnerability. A ...
[]
null
null
6.3
null
ICSA-17-318-02A
ABB TropOS (Update A)
An industry-wide vulnerability exists in the WPA2 key management algorithm devices that use IEEE 802.11w, including the TropOS broadband mesh routers listed above. The vulnerability may allow an attacker to decrypt, replay, and forge some frames on a WPA2 encrypted network.The following CVEs have been assigned to this ...
[]
null
null
null
null
ICSA-20-301-01
SHUN HU Technology JUUKO Industrial Radio Remote Control
K-800 is vulnerable to a replay attack and command forgery, which could allow attackers to replay commands, control the device, view commands, or cause the device to stop running.CVE-2018-17932 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:A/AC:L...
[]
null
null
7.5
null
ICSA-21-005-06
Delta Electronics CNCSoft ScreenEditor
A stack-based buffer overflow may exist when processing specially crafted project files, which may allow an attacker to execute arbitrary code.CVE-2020-27281 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-21-222-03
Siemens JT2Go and Teamcenter Visualization (Update A)
An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Open Design Alliance Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a ...
[]
null
3.3
null
null
ICSA-21-068-09
Siemens Solid Edge File Parsing
Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049) When opening a specially cra...
[]
null
7.8
null
null
ICSMA-18-144-01
BeaconMedaes TotalAlert Scroll Medical Air Systems
An attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.CVE-2018-7518 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/...
[]
null
null
7.5
null
ICSA-18-067-02
ICSA-18-067-02_Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension (Update B)
Successful exploitation of this vulnerability could allow an attacker to either upgrade or downgrade the firmware of the device, including downgrading to older versions with known vulnerabilities.CVE-2018-4838 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector stri...
[]
null
null
7.5
null
ICSA-22-118-01
Johnson Controls Metasys
Under certain circumstances, an authenticated user could elevate their privileges to administrator.CVE-2021-36207 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSA-21-105-02
EIPStackGroup OpENer Ethernet/IP
A specifically crafted packet sent by an attacker to the affected devices may cause a denial-of-service condition.CVE-2021-27478 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). A specifically crafted packet sent b...
[]
null
null
7.5
null
ICSA-22-167-11
Siemens Xpedition Designer
The affected application assigns improper access rights to the service executable. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
[]
null
7.8
null
null
ICSA-23-320-12
Siemens PNI
.NET and Visual Studio Information Disclosure Vulnerability. zlib through 1.2.12 has a heap-based buffer over-read or buffer overflow in inflate in inflate.c via a large gzip header extra field. NOTE: only applications that call inflateGetHeader are affected. Some common applications bundle the affected zlib source cod...
[]
null
7.3
null
null
ICSA-22-034-02
Airspan Networks Mimosa
The affected product does not perform proper authorization and authentication checks on multiple API routes. An attacker may gain access to these API routes and achieve remote code execution, create a denial-of-service condition, and obtain sensitive information.CVE-2022-21196 has been assigned to this vulnerability. A...
[]
null
null
6.5
null
ICSA-21-194-06
Siemens SIMATIC Software Products (Update B)
A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
[]
null
7.3
null
null
ICSA-23-278-01
Hitachi Energy AFS65x,AFF66x, AFS67x, and AFR67x Series Products
In Expat (aka libexpat) before 2.4.3, a left shift by 29(or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior (e.g., allocating too few bytes, or only freeing memory). In doProlog in xmlparse.c in Expat (aka libexpat) before 2.4.3, an integer overflow exists for m_groupSize. Vulnerabl...
[]
null
null
7.5
null
ICSA-21-315-08
Siemens NX OBJ Translator
The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointe...
[]
null
3.3
null
null
ICSA-21-313-06
OSIsoft PI Web API
A remote authenticated attacker with write access to a PI Server could trick a user into interacting with a PI Web API endpoint and redirect them to a malicious website. As a result, a victim may disclose sensitive information to the attacker or be provided with false information.CVE-2021-43549has been assigned to this...
[]
null
null
6.9
null
ICSA-23-031-01
Delta Electronics DOPSoft
Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.-CVE-2023-0123 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calcu...
[]
null
null
7.8
null