id stringlengths 12 16 | title stringlengths 6 140 | description stringlengths 76 139k | cpes listlengths 0 0 | cvss_v4_0 null | cvss_v3_1 float64 2.5 10 ⌀ | cvss_v3_0 float64 1.9 10 ⌀ | cvss_v2_0 null |
|---|---|---|---|---|---|---|---|
ICSA-22-242-11 | Sensormatic Electronics iSTAR | The affected product is vulnerable to a command injection that could allow an unauthenticated user root access to the system.CVE-2022-21941 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). | [] | null | null | 10 | null |
ICSA-24-270-03 | Atelmo Atemio AM 520 HD Full HD Satellite Receiver | The device enables an unauthorized attacker to execute system commands with elevated privileges. This exploit is facilitated through the use of the 'getcommand' query within the application, allowing the attacker to gain root access. | [] | null | 9.8 | null | null |
ICSA-18-151-03 | Yokogawa STARDOM Controllers (Update A) | The affected controllers utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.CVE-2018-10592 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (A... | [] | null | null | 5.3 | null |
ICSA-17-222-03 | Solar Controls WATTConfig M Software | An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file.CVE-2017-9648 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/... | [] | null | null | 7.8 | null |
ICSA-23-031-01 | Delta Electronics DOPSoft | Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.-CVE-2023-0123 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calcu... | [] | null | null | 7.8 | null |
ICSA-19-281-03 | Siemens SIMATIC WinAC RTX (F) 2010 (Update A) | Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the executing service. The security vulnerability could be exploited by an attacker with network access t... | [] | null | 7.5 | null | null |
ICSA-19-134-06 | Siemens SINAMICS PERFECT HARMONY GH180 Fieldbus Network | An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to com... | [] | null | null | 7.5 | null |
ICSA-19-311-01 | Mitsubishi Electric MELSEC-Q Series and MELSEC-L Series CPU Modules | A remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.CVE-2019-13555 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV... | [] | null | null | 7.5 | null |
ICSA-21-012-01 | Schneider Electric EcoStruxure Power Build-Rapsody (Update A) | A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. When a malicious SSD ... | [] | null | null | 7.8 | null |
ICSA-21-133-03 | OPC Foundation UA Products Built with .NET Framework | The affected products are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow.CVE-2021-27432 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-21-173-01 | Advantech WebAccess HMI Designer (Update A) | Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required.CVE-2021-33000 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/P... | [] | null | null | 5.4 | null |
ICSA-18-107-02 | Schneider Electric Triconex Tricon | System calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory. When a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow a... | [] | null | null | 7.9 | null |
ICSA-22-356-04 | Omron CX-Programmer | CX-Programmer is vulnerable to a Out-of-bounds Write when a user opens a specially crafted CXP file. This could cause a loss of sensitive information or arbitrary code execution.CVE-2022-43509 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR... | [] | null | null | 7.8 | null |
ICSA-24-023-02 | Crestron AM-300 | There is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access. | [] | null | 8.4 | null | null |
ICSA-20-063-02 | ICSA-20-063-02_PHOENIX CONTACT Emalytics Controller ILC | This device lacks proper permissions for read and write access to the configuration and start/stop services. CVE-2020-8768 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H). | [] | null | null | 9.4 | null |
ICSA-21-222-06 | Siemens Energy AGT and SGT Solutions | ** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. | [] | null | 9.8 | null | null |
ICSA-18-212-03 | WECON LeviStudioU (Update A) | Multiple stack-based buffer overflow vulnerabilities can be exploited when the application processes specially crafted project files.CVE-2018-10602 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Multiple heap-bas... | [] | null | null | 6.5 | null |
ICSA-24-235-04 | Avtec Outpost 0810 | Avtec Outpost stores sensitive information in an insecure location without proper access controls in place. Avtec Outpost uses a default cryptographic key that can be used to decrypt sensitive information | [] | null | 7.5 | null | null |
ICSA-20-212-04 | Mitsubishi Electric Factory Automation Engineering Products | Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. CVE-2020-14521 has been assigned to this vulnerability. A CVS... | [] | null | null | 8.3 | null |
ICSA-22-069-03 | Siemens SINEC NMS | A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application. The affected system allows to upload JSON objects that are deserialized to Java objects. Due to insecure deserialization of user-supplied content... | [] | null | 7.3 | null | null |
ICSA-19-255-04 | 3S-Smart Software Solutions GmbH CODESYS Control V3 OPC UA Server | Sending specific crafted requests from a trusted OPC UA client may cause a NULL pointer dereference, which may trigger a denial-of-service condition.CVE-2019-13542 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 6.5 | null |
ICSA-23-103-03 | Siemens in OPC Foundation Local Discovery Server | OPC Foundation Local Discovery Server (LDS) in affected products uses a hard-coded file path to a configuration file. This allows a normal user to create a malicious file that is loaded by LDS (running as a high-privilege user). | [] | null | 7.8 | null | null |
ICSA-21-040-09 | SIMATIC WinCC Graphics Designer | Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication. | [] | null | 6.2 | null | null |
ICSA-20-070-01 | ICSA-20-070-01_Siemens and PKE SiNVR/SiVMS Video Server (Update B) | The user configuration menu in the web interface of the Control Center Server (CCS) transfers user passwords in clear to the client (browser).
An attacker with administrative privileges for the web interface could be able to read (and not only reset) passwords of other CCS users. The Control Center Server (CCS) contai... | [] | null | 4.3 | null | null |
ICSA-23-033-03 | Baicells Nova | Baicells Nova 227, Nova 233, Nova 243 LTE TDD eNodeB devices and Nova 246 with firmware through RTS/RTD 3.6.6 are vulnerable to remote shell code exploitation via HTTP command injections. Commands are executed using pre-login execution and executed with root permissions.-CVE-2023-24508 has been assigned to this vulnera... | [] | null | null | 9.8 | null |
ICSA-18-282-05 | Siemens SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET 200SP OpenController (Update A) | An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploita... | [] | null | 5.3 | null | null |
ICSA-22-333-02 | Hitachi Energy IED Connectivity Packages and PCM600 Products | A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy 's PCM600 products in which IED credentials are stored in cleartext inside the PCM600 database. An unauthorized user who gains access to the exported backup file could exploit ... | [] | null | null | 7.1 | null |
ICSA-22-349-14 | Siemens SISCO MMS-EASE Third Party Component | The SNAP Lite component in certain SISCO MMS-EASE and AX-S4 ICCP products allows remote attackers to cause a denial of service (CPU consumption) via a crafted packet. | [] | null | 7.5 | null | null |
ICSA-23-243-04 | Digi RealPort Protocol | Digi RealPort Protocol is vulnerable to a replay attack that may allow an attacker to bypass authentication to access connected equipment. | [] | null | null | 9 | null |
ICSA-21-280-05 | InHand Networks IR615 Router (Update A) | The affected product 's management portal does not contain an X-FRAME-OPTIONS header, which an attacker may take advantage of by sending a link to an administrator that frames the router 's management portal and could lure the administrator to perform changes.CVE-2021-38472 has been assigned to this vulnerability. A CV... | [] | null | null | 9.8 | null |
ICSA-22-286-13 | Siemens LOGO! 8 BM Devices | Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. Affected devices do not conduct certain validations when interacting with them. This could allow an unauthentic... | [] | null | 5.3 | null | null |
ICSA-21-035-02 | Horner Automation Cscape | The affected application lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-22663 has been assigned to this vulnerability. A CVSS v3 base score of... | [] | null | null | 7.8 | null |
ICSA-23-026-01 | Delta Electronics CNCSoft ScreenEditor | All versions prior to Delta Electronic's CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.-CVE-2022-4634 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been... | [] | null | null | 7.8 | null |
ICSA-21-061-01 | Hitachi ABB Power Grids Ellipse EAM | An attacker could exploit this vulnerability by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user 's session.CVE-2021-27416 has been assigned to this vulnerability. A CVS... | [] | null | null | 5.5 | null |
ICSA-19-050-02 | Delta Industrial Automation CNCSoft | An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files.CVE-2019-6547 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L). | [] | null | null | 4.4 | null |
ICSA-18-296-03 | Telecrane F25 Series | These devices use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent stop state.CVE-2018-17935 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been ... | [] | null | null | 7.6 | null |
ICSA-18-065-03 | Eaton ELCSoft | There are multiple cases where specially crafted files could cause a buffer overflow which, in turn, may allow remote execution of arbitrary code. CVE-2018-7511 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L). | [] | null | null | 6.3 | null |
ICSA-19-192-07 | Schneider Electric Floating License Manager | A denial of service vulnerability related to preemptive item deletion in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down.CVE-2018-20031 ... | [] | null | null | 7.5 | null |
ICSA-21-119-02 | Cassia Networks Access Controller | An attacker may be able to use minify route with a relative path to view any file on the server.CVE-2021-22685 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 6.2 | null |
ICSMA-22-167-01 | Hillrom Medical Device Management | The affected products contain hard-coded (unchangeable) passwords used for inbound authentication or outbound communication to external components.CVE-2022-26388 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L). The... | [] | null | null | 7.7 | null |
ICSA-22-132-09 | Siemens JT2GO and Teamcenter Visualization | The Tiff_Loader.dll is vulnerable to infinite loop condition while parsing specially crafted TIFF files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted C... | [] | null | 7.8 | null | null |
ICSMA-19-120-01 | Philips Tasy EMR (Update A) | The software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. CVE-2019-6562 has been assigned to this vulnerability. A CVSS v3 base score of 4.1 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N).. -... | [] | null | null | 4.3 | null |
ICSA-23-047-09 | Siemens SIMATIC Industrial Products | Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. | [] | null | 7.9 | null | null |
ICSA-24-228-06 | Siemens SINEC NMS | A use-after-free flaw was found in mm/mempolicy.c in the memory management subsystem in the Linux Kernel. This issue is caused by a race between mbind() and VMA-locked page fault, and may allow a local attacker to crash the system or lead to a kernel information leak. A memory disclosure vulnerability was found in Post... | [] | null | 4.3 | null | null |
ICSA-17-306-02 | Advantech WebAccess | The application lacks proper validation of the length of user-supplied data prior to copying it to a stack-based buffer, which could allow an attacker to execute arbitrary code under the context of the process.CVE-2017-14016 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVS... | [] | null | null | 7.3 | null |
ICSA-23-103-08 | Siemens Mendix Forgot Password Module | Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. | [] | null | 7.3 | null | null |
ICSMA-19-080-01 | Medtronic Conexus Radio Frequency Telemetry Protocol (Update C) | The Conexus telemetry protocol utilized within this ecosystem does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product 's radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communicati... | [] | null | null | 6.5 | null |
ICSA-23-262-03 | Omron Engineering Software Zip-Slip | DotNetZip.Semvered before 1.11.0 is vulnerable to directory traversal, which could allow attackers to write to arbitrary files via a ../ (dot dot slash) in a Zip archive entry mishandled during extraction. This vulnerability is also known as "Zip-Slip." | [] | null | null | 5.5 | null |
ICSA-24-228-09 | Siemens NX | The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process. | [] | null | 7.8 | null | null |
ICSA-22-349-03 | Siemens Multiple Denial of Service Vulnerabilities in Industrial Products | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of servi... | [] | null | 4.9 | null | null |
ICSA-21-173-02 | CODESYS V2 web server | Crafted web server requests may cause a stack-based buffer overflow. This could allow an attacker to execute arbitrary code on the CODESYS web server or trigger a denial-of-service condition due to a crash in the CODESYS web server.CVE-2021-30189 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has ... | [] | null | null | 9.1 | null |
ICSA-21-042-01 | Multiple Embedded TCP/IP Stacks (Update B) | Nut/Net software relies on highly predictable source values and has consistent increments when generating initial sequence numbers (ISN), which may allow an attacker to spoof or disrupt TCP connections.CVE-2020-27213 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vect... | [] | null | null | 6.5 | null |
ICSA-19-253-01 | Delta Electronics TPEditor | Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code.CVE-2019-13540 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/... | [] | null | null | 7.8 | null |
ICSA-22-167-08 | Siemens SICAM GridEdge | The affected software does not apply cross-origin resource sharing (CORS) restrictions for critical operations. In case an attacker tricks a legitimate user into accessing a special resource a malicious request could be executed. The affected software does not require authenticated access for privileged functions. This... | [] | null | 4.9 | null | null |
ICSA-24-228-06 | Siemens SINEC NMS | A use-after-free flaw was found in mm/mempolicy.c in the memory management subsystem in the Linux Kernel. This issue is caused by a race between mbind() and VMA-locked page fault, and may allow a local attacker to crash the system or lead to a kernel information leak. A memory disclosure vulnerability was found in Post... | [] | null | 4.3 | null | null |
ICSA-18-298-01 | GEOVAP Reliance 4 SCADA/HMI | This vulnerability could allow an unauthorized attacker to inject arbitrary code.CVE-2018-17904 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). | [] | null | null | 6.1 | null |
ICSA-21-110-07 | Siemens Mendix | Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges. | [] | null | 8.1 | null | null |
ICSA-23-234-01 | Hitachi Energy AFF66x | In uClibc and uClibc-ng before 1.0.39, incorrect handling of special characters in domain names DNS servers returned via gethostbyname, getaddrinfo, gethostbyaddr, and getnameinfo could lead to output of wrong hostnames (leading to domain hijacking) or injection into applications (leading to remote code execution, XSS,... | [] | null | null | 7.5 | null |
ICSA-21-056-01 | PerFact OpenVPN-Client | An attacker can take leverage on this architecture and send the config command from any application running on the local host machine to force the back-end server into initializing a new open-VPN instance with arbitrary open-VPN configuration. This could result in the attacker achieving execution with privileges of a S... | [] | null | null | 8.8 | null |
ICSA-20-238-02 | Emerson OpenEnterprise | Inadequate encryption may allow the credentials used by OpenEnterprise to access field devices and external systems to be obtained.CVE-2020-16235 has been assigned to this vulnerability. A CVSS v3 base score of 3.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N). | [] | null | null | 3.8 | null |
ICSA-22-349-19 | Siemens SICAM PAS | Affected software does not properly secure a folder containing library files. This could allow an attacker to place a custom malicious DLL in this folder which is then run with SYSTEM rights when a service is started that requires this DLL.
At the time of assigning the CVE, the affected firmware version of the compone... | [] | null | 8.3 | null | null |
ICSA-22-195-17 | Siemens Opcenter Quality | The affected applications do not properly validate login information during authentication. This could lead to denial of service condition for existing users or allow unauthenticated remote attackers to successfully login without credentials. | [] | null | 9.6 | null | null |
ICSA-23-045-01 | Weintek EasyBuilder Pro cMT Series | The listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user's computer or gain access to sensitive data. CVE-2023-0104 has been assigned to this vulnerability. A CVSS v3 base score of 9.3 has b... | [] | null | null | 9.3 | null |
ICSA-18-011-03 | PHOENIX CONTACT FL SWITCH | A remote unauthenticated attacker may be able to craft special HTTP requests allowing an attacker to bypass web-service authentication allowing the attacker to obtain administrative privileges on the device. CVE-2017-16743 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS ... | [] | null | null | 5.3 | null |
ICSA-18-198-02 | WAGO e!DISPLAY Web-Based-Management | Authenticated and unauthenticated users can send specially crafted requests to the web server, which allows code injection within the WBM. The code will be rendered and/or executed within the user 's browser.CVE-2018-12981 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been calculated; the CVS... | [] | null | null | 8 | null |
ICSA-22-195-03 | Siemens SIMATIC MV500 Devices | The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users' sessions. Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker... | [] | null | 7.5 | null | null |
ICSA-18-200-03 | Echelon SmartServer 1, SmartServer 2, SmartServer 3, i.LON 100, i.LON 600 (Update A) | An attacker can use the SOAP API to retrieve and change sensitive configuration items such as the usernames and passwords for the Web and FTP servers. This vulnerability does not affect the i.LON 600 product.CVE-2018-10627 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVS... | [] | null | null | 9.8 | null |
ICSA-18-065-01 | Hirschmann Automation and Control GmbH Classic Platform Switches | A session fixation vulnerability in the web interface has been identified, which may allow an attacker to hijack web sessions. CVE-2018-5465 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H). An information exposure ... | [] | null | null | 7.5 | null |
ICSA-23-348-12 | Siemens SCALANCE and RUGGEDCOM M-800/S615 Family | Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device. An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the ... | [] | null | 7.2 | null | null |
ICSA-24-074-14 | Mitsubishi Electric MELSEC-Q/L Series (Update B) | In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet. In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to execute malicious code on a ta... | [] | null | 9.8 | null | null |
ICSMA-22-251-01 | Baxter Sigma Spectrum Infusion Pump (Update A) | The Baxter Spectrum WBM (v16, v16D38, v17, v17D19, v20D29 to v20D32, and v22D19 to v22D28) stores network credentials and patient health information (PHI) in unencrypted form. PHI is only stored in Spectrum IQ pumps using auto programming. An attacker with physical access to a device without all data and settings erase... | [] | null | null | 7.5 | null |
ICSA-20-142-01 | Johnson Controls Software House C-CURE 9000 and American Dynamics victor VMS | During installation or upgrade to C•CURE 9000 v2.70 and victor Video Management System v5.2, the credentials of the user performing the installation or upgrade are saved in a file. The install log file persists after the installation.CVE-2020-9045 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has... | [] | null | null | 9.9 | null |
ICSA-19-015-01 | LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA | Opening a specially crafted report format file allows execution of script code, which may allow remote code execution, data exfiltration, or cause a system crash.CVE-2018-18988 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:... | [] | null | null | 5.3 | null |
ICSA-22-195-02 | Siemens SICAM GridEdge | Affected software uses an improperly protected file to import SSH keys. Attackers with access to the filesystem of the host on which SICAM GridEdge runs, are able to inject a custom SSH key to that file. | [] | null | 6.3 | null | null |
ICSA-17-152-02 | NXP i.MX Product Family | When the device is configured in security enabled configuration. SDP could be used to download a small section of code to an unprotected region of memory.CVE-2017-7936 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:L).... | [] | null | null | 6 | null |
ICSA-21-343-01 | Hitachi Energy GMS600, PWC600, and Relion | An attacker could exploit this vulnerability by first gaining access to credentials of any account or have access to a session ticket issued for an account. After gaining access via the configuration tool that accesses the proprietary Open Data-base Connectivity (ODBC) protocol (TCP 2102), the database table can be man... | [] | null | null | 7.2 | null |
ICSMA-23-180-01 | Medtronic Paceart Optima System | If a healthcare delivery organization has enabled the optional Paceart Messaging Service in the Paceart Optima system, an unauthorized user could exploit this vulnerability to perform remote code execution and/or denial-of-service (DoS) attacks by sending specially crafted messages to the Paceart Optima system. Remote ... | [] | null | null | 9.8 | null |
ICSA-21-350-17 | Siemens JT Utilities and JT Open Toolkit | JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14829) JTTK library in affected products is vulnerable to an out of boun... | [] | null | 7.8 | null | null |
ICSA-20-161-02 | Mitsubishi Electric MELSEC iQ-R Series (Update C) | An attacker can cause a denial-of-service condition at the Ethernet port by sending a specially crafted packet.CVE-2020-13238 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). | [] | null | null | 5.3 | null |
ICSA-23-157-02 | Mitsubishi Electric MELSEC iQ-R Series/iQ-F Series | Authentication bypass vulnerability in FTP function on EtherNet/IP module due to weak password requirements allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing. Authentication bypass vulnerability in FTP function on EtherNet/IP module due to use of hard-co... | [] | null | null | 6.3 | null |
ICSA-22-349-07 | Siemens Simcenter STAR-CCM+ | The affected application improperly assigns file permissions to installation folders.
This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges. | [] | null | 7.8 | null | null |
ICSA-20-266-01 | GE Digital APM Classic | CVE-2020-16240 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). An insecure direct object reference (IDOR) vulnerability allows user account data to be downloaded in JavaScript object notation (JSON) format by user... | [] | null | null | 7.2 | null |
ICSA-17-334-01 | Siemens SWT3000 | The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained. SWT3000 with TPOP is not affected by this vulnerability.CVE-2016-4784 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculat... | [] | null | null | 4.3 | null |
ICSA-21-287-01 | Schneider Electric CNM | The affected product has an issue with privilege management, which could cause an arbitrary command execution when the software is configured with specially crafted event actions.CVE-2021-22801 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L... | [] | null | null | 7.8 | null |
ICSA-21-131-02 | Mitsubishi Electric GOT and Tension Controller (Update A) | An attacker could exploit this vulnerability to cause a denial-of-service condition in the MODBUS/TCP server communication function of GOT2000 series, GOT SIMPLE series, SoftGOT2000 and Tension Controller.CVE-2021-20589 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS v... | [] | null | null | 5.9 | null |
ICSA-23-024-01 | XINJE XD | A zip slip vulnerability in XINJE XD/E Series PLC Program Tool up to version v3.5.1 could provide an attacker with arbitrary file write privilege when opening a specially crafted project file. This vulnerability can be triggered by manually opening an infected project file, or by initiating an upload program request fr... | [] | null | null | 7.3 | null |
ICSA-19-337-01 | Reliable Controls LicenseManager | An authenticated user may be able to insert malicious code into the system root path, which may allow execution of code with elevated privileges of the application.CVE-2019-18245 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/... | [] | null | null | 7.8 | null |
ICSA-22-263-03 | Dataprobe iBoot-PDU | A specific function does not sanitize the input provided by the user, which may expose the affected an OS command injection vulnerability. CVE-2022-3183 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The device�s e... | [] | null | null | 6.5 | null |
ICSA-22-258-05 | Siemens SINEC INS | The package ua-parser-js before 0.7.23 are vulnerable to Regular Expression Denial of Service (ReDoS) in multiple regexes (see linked commit for more info). json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_memappend. Axios NPM package 0.21.0 contains... | [] | null | 5.3 | null | null |
ICSA-24-046-16 | Rockwell Automation FactoryTalk Service Platform | A privilege escalation vulnerability exists in FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and ... | [] | null | 9 | null | null |
ICSA-18-345-02 | Siemens SINUMERIK Controllers (Update A) | The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the f... | [] | null | null | 10 | null |
ICSA-20-070-05 | Johnson Controls Metasys | An XXE vulnerability exists that may allow an attacker to harvest ASCII files from the server.CVE-2020-9044 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-21-217-03 | ICSA-21-217-03_mySCADA myPRO | The affected product does not restrict unauthorized read access to sensitive system information.CVE-2021-33013 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N). The affected product allows an unauthenticated remote ... | [] | null | null | 7.5 | null |
ICSA-24-074-14 | Mitsubishi Electric MELSEC-Q/L Series (Update B) | In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet. In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to execute malicious code on a ta... | [] | null | 9.8 | null | null |
ICSA-22-314-05 | Siemens RUGGEDCOM ROS | Affected devices improperly handle partial HTTP requests which makes them vulnerable to slowloris attacks.
This could allow a remote attacker to create a denial of service condition that persists until the attack ends. | [] | null | 5.3 | null | null |
ICSMA-17-229-01 | ICSMA-17-229-01_Philips' DoseWise Portal Vulnerabilities | The backend database of the DWP application uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application... | [] | null | null | 6.5 | null |
ICSA-22-179-04 | Motorola Solutions MOSCAD IP and ACE IP Gateways | The product lacks authentication features, which could allow any attacker capable of communicating with the port in question to invoke a variety of engineer actions, such as manipulation of RTU configurations or logic/applications.CVE-2022-30276 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has b... | [] | null | null | 7.5 | null |
ICSA-22-181-03 | Emerson DeltaV Distributed Control System | Several protocols, including Firmware upgrade, Plug-and-Play, Hawk services, Management, SIS communications, and multi-cast have no authentication. This could allow an attacker who has reverse-engineered communications to invoke desired functionality or cause a denial-of-service condition.CVE-2022-29957 has been assign... | [] | null | null | 8.8 | null |
ICSA-19-353-04 | Reliable Controls MACH-ProWebCom/Sys | An authenticated user clicking on a malicious link may allow an attacker to execute commands on behalf of the affected user.CVE-2019-18249 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:L). | [] | null | null | 8.2 | null |
ICSA-22-174-04 | Pyramid Solutions EtherNet/IP Adapter Development Kit | The affected products are vulnerable to an out-of-bounds write, which may allow an unauthorized attacker to send a specially crafted packet that may result in a denial-of-service condition.CVE-2022-1737 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV... | [] | null | null | 9.8 | null |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.