FeelAuthors commited on
Commit
0c13e24
·
verified ·
1 Parent(s): 4963122

README: drop gaze/IMU claims (not exported), scope hand-pose description to what is in the parquet, relabel unlabelled collector D->C

Browse files
Files changed (1) hide show
  1. README.md +13 -8
README.md CHANGED
@@ -14,7 +14,7 @@ size_categories:
14
 
15
  # FEEL-Benchmark
16
 
17
- A multimodal egocentric manipulation dataset combining **Project Aria** smart-glasses recordings (RGB video, eye gaze, hand tracking, IMU) with synchronized **PX6AX-GEN3-DP-S2015-Elite** fingertip tactile-sensor readings. Released in [LeRobot v3.0](https://github.com/huggingface/lerobot) format (GR00T path variant).
18
 
19
  ## Overview
20
 
@@ -22,10 +22,9 @@ A multimodal egocentric manipulation dataset combining **Project Aria** smart-gl
22
  - **Recording dates**: 2026-01-10, 2026-01-21, 2026-01-28, 2026-04-30, 2026-05-06, 2026-08-05, 2026-08-06, 2026-08-07
23
  - **Camera**: Project Aria RGB (1408×1408, **10 fps**, MPEG-4 Part 2 / `mpeg4`, yuv420p)
24
  - **Tactile**: two PX6AX-GEN3-DP-S2015-Elite fingertip sensor modules (thumb tip + index fingertip), 3-axis force logged at ~1 kHz
25
- - **Hand pose**: Aria MPS hand tracking (left + right, validity flags, confidence)
26
- - **Gaze**: Aria MPS general eye gaze (yaw/pitch + depth)
27
  - **Mean episode length**: 3.1 s (101,219 frames @ 10 fps)
28
- - **3 collectors**, anonymized as Collector A / B / D
29
 
30
  ## Release history
31
 
@@ -41,7 +40,7 @@ A multimodal egocentric manipulation dataset combining **Project Aria** smart-gl
41
 
42
  v2 adds the 2026-08-05/06/07 sessions (+2,637 episodes) and replaces `P25_bottle` and `P75_bottle`
43
  with re-segmented versions (−20 episodes). All v1 trials were recorded by a single person
44
- (Collector D); v2 introduces Collector A and Collector B, which makes cross-collector evaluation
45
  possible. The shorter mean episode length reflects finer segmentation in the v2 sessions
46
  (2026-08-07 averages 2.3 s/episode vs. 5.6 s in v1), not a change of task.
47
 
@@ -75,16 +74,19 @@ possible. The shorter mean episode length reflects finer segmentation in the v2
75
 
76
  ### By collector
77
 
78
- Trial directories carry a `collectorA` / `collectorB` infix. **Trials with no collector infix were recorded by Collector D.** The mapping between these labels and the people who recorded the data is not released.
79
 
80
  | Collector | Trials | Episodes | Frames | Duration (min) |
81
  |-----------|-------:|---------:|-------:|---------------:|
82
  | Collector A | 10 | 1,036 | 27,271 | 45.5 |
83
  | Collector B | 5 | 829 | 15,130 | 25.2 |
84
- | Collector D | 37 | 1,452 | 58,818 | 98.0 |
85
 
86
  The 2026-08-07 session is the only one recorded by multiple collectors on the same objects, which makes it usable as a cross-collector generalization split.
87
 
 
 
 
88
  ## Layout
89
 
90
  Datasets are grouped by recording session date:
@@ -175,7 +177,10 @@ Each `meta/info.json` declares `"path_format": "groot"`. The `data_path` and `vi
175
 
176
  ## Sensors
177
 
178
- - **Project Aria** (RGB, eye-tracking cameras, SLAM cameras, IMUs) with MPS post-processing for gaze + hand tracking
 
 
 
179
  - **PX6AX-GEN3-DP-S2015-Elite** fingertip tactile sensors — two modules on the right hand (thumb tip,
180
  index fingertip). Each module reports 3-axis combined force plus distributed per-taxel forces over a
181
  serial link at ~1 kHz. Only the combined-force magnitudes are exported here; raw per-taxel data is
 
14
 
15
  # FEEL-Benchmark
16
 
17
+ A multimodal egocentric manipulation dataset combining **Project Aria** smart-glasses RGB video and MPS hand tracking with synchronized **PX6AX-GEN3-DP-S2015-Elite** fingertip tactile-sensor readings. Released in [LeRobot v3.0](https://github.com/huggingface/lerobot) format (GR00T path variant).
18
 
19
  ## Overview
20
 
 
22
  - **Recording dates**: 2026-01-10, 2026-01-21, 2026-01-28, 2026-04-30, 2026-05-06, 2026-08-05, 2026-08-06, 2026-08-07
23
  - **Camera**: Project Aria RGB (1408×1408, **10 fps**, MPEG-4 Part 2 / `mpeg4`, yuv420p)
24
  - **Tactile**: two PX6AX-GEN3-DP-S2015-Elite fingertip sensor modules (thumb tip + index fingertip), 3-axis force logged at ~1 kHz
25
+ - **Hand pose**: right-hand thumb-tip and index-tip positions from Aria MPS hand tracking, plus a per-frame validity flag
 
26
  - **Mean episode length**: 3.1 s (101,219 frames @ 10 fps)
27
+ - **3 collectors**, anonymized as Collector A / B / C
28
 
29
  ## Release history
30
 
 
40
 
41
  v2 adds the 2026-08-05/06/07 sessions (+2,637 episodes) and replaces `P25_bottle` and `P75_bottle`
42
  with re-segmented versions (−20 episodes). All v1 trials were recorded by a single person
43
+ (Collector C); v2 introduces Collector A and Collector B, which makes cross-collector evaluation
44
  possible. The shorter mean episode length reflects finer segmentation in the v2 sessions
45
  (2026-08-07 averages 2.3 s/episode vs. 5.6 s in v1), not a change of task.
46
 
 
74
 
75
  ### By collector
76
 
77
+ Trial directories carry a `collectorA` / `collectorB` infix. **Trials with no collector infix were recorded by Collector C**, who recorded alone up to 2026-05-06 and continued alongside A and B in the August sessions. The mapping between these labels and the people who recorded the data is not released.
78
 
79
  | Collector | Trials | Episodes | Frames | Duration (min) |
80
  |-----------|-------:|---------:|-------:|---------------:|
81
  | Collector A | 10 | 1,036 | 27,271 | 45.5 |
82
  | Collector B | 5 | 829 | 15,130 | 25.2 |
83
+ | Collector C | 37 | 1,452 | 58,818 | 98.0 |
84
 
85
  The 2026-08-07 session is the only one recorded by multiple collectors on the same objects, which makes it usable as a cross-collector generalization split.
86
 
87
+ A fourth person also recorded during the August sessions, but those recordings are still being
88
+ processed and are **not part of this release**; they will be added under a `collectorD` infix.
89
+
90
  ## Layout
91
 
92
  Datasets are grouped by recording session date:
 
177
 
178
  ## Sensors
179
 
180
+ - **Project Aria** (RGB, eye-tracking cameras, SLAM cameras, IMUs) with MPS post-processing for hand
181
+ tracking. The recordings also contain eye gaze, SLAM trajectory and IMU streams, but **this release
182
+ exports only the RGB video and the two hand-landmark positions listed above** — gaze, full 21-joint
183
+ hand landmarks, left-hand data, device pose and IMU are not included in the parquet files.
184
  - **PX6AX-GEN3-DP-S2015-Elite** fingertip tactile sensors — two modules on the right hand (thumb tip,
185
  index fingertip). Each module reports 3-axis combined force plus distributed per-taxel forces over a
186
  serial link at ~1 kHz. Only the combined-force magnitudes are exported here; raw per-taxel data is