FeelAuthors commited on
Commit
762f6d2
·
verified ·
1 Parent(s): 9d7901c

README: document the new per-axis tactile force columns

Browse files
Files changed (1) hide show
  1. README.md +54 -18
README.md CHANGED
@@ -21,7 +21,7 @@ A multimodal egocentric manipulation dataset combining **Project Aria** smart-gl
21
  - **52 trials**, **3,317 episodes**, **~2.8 h** of segmented manipulation, ~4.6 GB
22
  - **Recording dates**: 2026-01-10, 2026-01-21, 2026-01-28, 2026-04-30, 2026-05-06, 2026-08-05, 2026-08-06, 2026-08-07
23
  - **Camera**: Project Aria RGB (1408×1408, **10 fps**, MPEG-4 Part 2 / `mpeg4`, yuv420p)
24
- - **Tactile**: two PX6AX-GEN3-DP-S2015-Elite fingertip sensor modules on the right hand; one force magnitude per module per frame, resampled to the 10 fps video grid (raw logs ran at ~900 Hz in 2026-01/04/05 and ~91 Hz in the August sessions)
25
  - **Hand pose**: right-hand thumb-tip and index-tip positions from Aria MPS hand tracking, plus a per-frame validity flag
26
  - **Mean episode length**: 3.1 s (101,219 frames @ 10 fps)
27
  - **4 collectors**, anonymized as Collector A / B / C / D
@@ -45,6 +45,11 @@ different people (Collectors A, B and D), which makes cross-collector evaluation
45
  shorter mean episode length reflects finer segmentation in the v2 sessions (2026-08-07 averages
46
  2.3 s/episode vs. 5.6 s in v1), not a change of task.
47
 
 
 
 
 
 
48
  ## Dataset statistics
49
 
50
  ### By recording date
@@ -153,6 +158,8 @@ Each row in `episode_*.parquet`:
153
  | `status.hands.valid_right` | bool | (1,) | Right-hand tracking validity |
154
  | `action.tactile.left.force_total` | float32 | (1,) | Sensor module **1** force magnitude (raw counts) |
155
  | `action.tactile.right.force_total` | float32 | (1,) | Sensor module **2** force magnitude (raw counts) |
 
 
156
  | `observation.images.main` | video | 1408×1408×3 | Aria RGB stream (`mpeg4`, yuv420p, 10 fps) |
157
 
158
  ### Note on the `left` / `right` tactile column names
@@ -164,26 +171,54 @@ the raw log rather than by name.
164
 
165
  Which fingers those two modules sat on is **not** the same in every session:
166
 
167
- | Trials | Module 1 (`…left.force_total`) | Module 2 (`…right.force_total`) |
168
- |--------|--------------------------------|---------------------------------|
169
  | the 45 trials under `20260110/` … `20260506/` and `20260807/` | thumb tip | index fingertip |
170
  | the 7 trials under `20260805/` and `20260806/` | **middle-finger tip** | **little-finger tip** |
171
 
172
- Treat the two columns as "module 1 / module 2" and consult this table before pooling sessions.
173
- `modality.json` exposes the same two values as `module1_force_total` / `module2_force_total`, and each
174
- trial's `description` field names the finger that module was mounted on in that session.
175
-
176
- Each value is the magnitude `sqrt(Fx² + Fy² + Fz²)` of that module's 3-axis combined force, in
177
- **raw signed-16-bit sensor counts — not newtons**. No force calibration was applied, so the values
178
- are suitable for relative/temporal analysis (contact onset, grip modulation) but not for absolute
179
- force comparison across sessions. The per-axis `Fx/Fy/Fz` components and the distributed per-taxel
180
- readings are not part of this release — only the combined magnitude.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
181
 
182
  ### Note on tactile sampling
183
 
184
  The tactile stream is logged independently of the camera and then **linearly interpolated onto each
185
- video frame's timestamp**, so the dataset carries exactly one value per module per frame at 10 Hz.
186
- Raw log rates differ by session:
187
 
188
  | Sessions | Trials | Raw log rate | Host-timestamp resolution |
189
  |----------|-------:|--------------|---------------------------|
@@ -217,10 +252,11 @@ Each `meta/info.json` declares `"path_format": "groot"`. The `data_path` and `vi
217
  exports only the RGB video and the two hand-landmark positions listed above** — gaze, full 21-joint
218
  hand landmarks, left-hand data, device pose and IMU are not included in the parquet files.
219
  - **PX6AX-GEN3-DP-S2015-Elite** fingertip tactile sensors — two modules on the right hand. The sensor
220
- hardware reports 3-axis combined force plus distributed per-taxel forces over a serial link; the
221
- logger recorded the two enabled modules at ~900 Hz (2026-01/04/05) or ~91 Hz (August). Only the
222
- combined-force magnitude of each module is exported here, linearly interpolated onto the 10 fps video
223
- frame grid — per-axis components and per-taxel data are not included in this release. See
 
224
  [the note above](#note-on-the-left--right-tactile-column-names) for which fingers the two modules
225
  were mounted on in each session.
226
 
 
21
  - **52 trials**, **3,317 episodes**, **~2.8 h** of segmented manipulation, ~4.6 GB
22
  - **Recording dates**: 2026-01-10, 2026-01-21, 2026-01-28, 2026-04-30, 2026-05-06, 2026-08-05, 2026-08-06, 2026-08-07
23
  - **Camera**: Project Aria RGB (1408×1408, **10 fps**, MPEG-4 Part 2 / `mpeg4`, yuv420p)
24
+ - **Tactile**: two PX6AX-GEN3-DP-S2015-Elite fingertip sensor modules on the right hand; per module and per frame, a 3-axis force vector `(Fx, Fy, Fz)` plus its magnitude, resampled to the 10 fps video grid (raw logs ran at ~900 Hz in 2026-01/04/05 and ~91 Hz in the August sessions)
25
  - **Hand pose**: right-hand thumb-tip and index-tip positions from Aria MPS hand tracking, plus a per-frame validity flag
26
  - **Mean episode length**: 3.1 s (101,219 frames @ 10 fps)
27
  - **4 collectors**, anonymized as Collector A / B / C / D
 
45
  shorter mean episode length reflects finer segmentation in the v2 sessions (2026-08-07 averages
46
  2.3 s/episode vs. 5.6 s in v1), not a change of task.
47
 
48
+ **v2.1 (2026-08-11)** adds the per-axis tactile columns `action.tactile.module1.force_xyz` and
49
+ `action.tactile.module2.force_xyz` to every episode parquet, recovered from the raw tactile logs and
50
+ resampled with the same interpolation that produced the existing `force_total` columns. Trial,
51
+ episode and frame counts are unchanged, as are the 14 pre-existing columns and all videos.
52
+
53
  ## Dataset statistics
54
 
55
  ### By recording date
 
158
  | `status.hands.valid_right` | bool | (1,) | Right-hand tracking validity |
159
  | `action.tactile.left.force_total` | float32 | (1,) | Sensor module **1** force magnitude (raw counts) |
160
  | `action.tactile.right.force_total` | float32 | (1,) | Sensor module **2** force magnitude (raw counts) |
161
+ | `action.tactile.module1.force_xyz` | float32 | (3,) | Sensor module **1** 3-axis force `[Fx, Fy, Fz]` (raw counts) |
162
+ | `action.tactile.module2.force_xyz` | float32 | (3,) | Sensor module **2** 3-axis force `[Fx, Fy, Fz]` (raw counts) |
163
  | `observation.images.main` | video | 1408×1408×3 | Aria RGB stream (`mpeg4`, yuv420p, 10 fps) |
164
 
165
  ### Note on the `left` / `right` tactile column names
 
171
 
172
  Which fingers those two modules sat on is **not** the same in every session:
173
 
174
+ | Trials | Module 1 (`…left.force_total`, `…module1.force_xyz`) | Module 2 (`…right.force_total`, `…module2.force_xyz`) |
175
+ |--------|------------------------------------------------------|------------------------------------------------------|
176
  | the 45 trials under `20260110/` … `20260506/` and `20260807/` | thumb tip | index fingertip |
177
  | the 7 trials under `20260805/` and `20260806/` | **middle-finger tip** | **little-finger tip** |
178
 
179
+ Treat the columns as "module 1 / module 2" and consult this table before pooling sessions.
180
+ `modality.json` exposes the four values as `module1_force_total` / `module2_force_total` /
181
+ `module1_force_xyz` / `module2_force_xyz`, and each entry's `description` field names the finger that
182
+ module was mounted on in that session.
183
+
184
+ The `force_total` value is the magnitude `sqrt(Fx² + Fy² + Fz²)` of that module's 3-axis combined
185
+ force, in **raw signed-16-bit sensor counts — not newtons**. No force calibration was applied, so
186
+ the values are suitable for relative/temporal analysis (contact onset, grip modulation) but not for
187
+ absolute force comparison across sessions. The distributed per-taxel readings are not part of this
188
+ release.
189
+
190
+ The two `force_xyz` columns use the neutral `module1` / `module2` names rather than the legacy
191
+ `left` / `right`; `module1.force_xyz` pairs with `left.force_total`, and `module2.force_xyz` with
192
+ `right.force_total`.
193
+
194
+ ### Note on the 3-axis force components
195
+
196
+ `action.tactile.module{1,2}.force_xyz` hold the per-axis combined force `[Fx, Fy, Fz]` in the same
197
+ raw signed-16-bit counts as `force_total`. Two caveats:
198
+
199
+ - **The axes are the sensor module's own local frame.** Each module's orientation on the fingertip
200
+ was not recorded, so the axes are not expressed in a hand, camera or world frame, and they are not
201
+ directly comparable across modules or sessions. Empirically `Fz` carries most of the magnitude
202
+ (mean |Fz|/‖F‖ = 0.78; `Fz` is the largest-magnitude axis in 67–70 % of frames), consistent with
203
+ `Fz` being the axis normal to the sensing pad and `Fx`/`Fy` the two shear components — but that is
204
+ an observation about this data, not a calibrated fact.
205
+ - **‖(Fx, Fy, Fz)‖ is not exactly equal to `force_total`.** The magnitude and the vector were each
206
+ interpolated onto the video frame grid independently, and linear interpolation does not commute
207
+ with taking a norm when the force direction rotates between two raw samples. The two agree exactly
208
+ at raw sample times; between them they differ by ≤ 0.01 counts on 96.8 % of frames, with a p99 of
209
+ 0.03 and a worst case of 0.86 counts (`force_total` itself has p50 = 6.1, p99 = 79.9, max = 143.4
210
+ counts). Use `force_total` when you want the scalar the original pipeline produced, and
211
+ `force_xyz` when you want direction.
212
+
213
+ Across the 69.1 M raw samples behind this release the per-axis values span `[-128, 255]` counts, and
214
+ `[-128, 136]` after resampling; the extreme values are each ~0.002 % of samples, so no material
215
+ clipping occurs.
216
 
217
  ### Note on tactile sampling
218
 
219
  The tactile stream is logged independently of the camera and then **linearly interpolated onto each
220
+ video frame's timestamp**, so the dataset carries exactly one magnitude and one 3-axis vector per
221
+ module per frame at 10 Hz. Raw log rates differ by session:
222
 
223
  | Sessions | Trials | Raw log rate | Host-timestamp resolution |
224
  |----------|-------:|--------------|---------------------------|
 
252
  exports only the RGB video and the two hand-landmark positions listed above** — gaze, full 21-joint
253
  hand landmarks, left-hand data, device pose and IMU are not included in the parquet files.
254
  - **PX6AX-GEN3-DP-S2015-Elite** fingertip tactile sensors — two modules on the right hand. The sensor
255
+ hardware reports 3-axis combined force (each axis a 16-bit signed value) plus distributed per-taxel
256
+ forces over a serial link; the logger recorded the two enabled modules at ~900 Hz (2026-01/04/05)
257
+ or ~91 Hz (August). The combined force of each module is exported here both as a magnitude and as
258
+ its three axis components, linearly interpolated onto the 10 fps video frame grid — the per-taxel
259
+ data is not included in this release. See
260
  [the note above](#note-on-the-left--right-tactile-column-names) for which fingers the two modules
261
  were mounted on in each session.
262