38.533
16.7.5 E-UTRAN RSRP for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.0.1 E-UTRAN RSRP absolute accuracy
When RedCap UE is capable of 2Rx, the minimum requirements given in clause 6.7.5.0.1 shall apply. When RedCap UE is only required to support 1Rx, the requirements for absolute accuracy of RSRP in this clause apply to a cell that has different carrier frequency from the serving cell. The accuracy requirements in Table 1...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1 NR SA FR1 - E-UTRA RSRP absolute measurement accuracy for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.1 Test purpose
To verify that the E-UTRAN RSRP measurement accuracy is within the specified limits. This test will verify the requirements in TS 38.133 [6] clause 10.2A.2 for SA inter-RAT E-UTRAN RSRP measurements.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.2 Test applicability
This test applies to all types of NR RedCap UEs with 1Rx from Release 17 onwards and supporting E-UTRA.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.5.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.5.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.5.1.4.1 with following exceptions: - Table 6.7.5.1.4.1-1 is replaced by Table 16.7.5.1.4.1-1; - Table 6.7.5.1.4.1-2 is replaced by Table 16.7.5.1.4.1-2; Table 16.7.5.1.4.1-1: Supported test configurations Configuration Description 16.7.5.1-1 NR 15 kHz SSB SCS, 10 MHz b...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.5.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.4.3 Message contents
Same as the message contents given in 6.7.5.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.1.5 Test requirement
Same as the test requirements given in clause 6.7.5.1.5 with following exceptions: - Table 6.7.5.1.5-1 is replaced by Table 16.7.5.1.5-1; - Table 6.7.5.1.5-2 is replaced by Table 16.7.5.1.5-2; - Table 6.7.5.1.5-3 is replaced by Table 16.7.5.1.5-3; Table 16.7.5.1.5-1: NR Cell specific test parameters (Cell 1) Parameter ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2 NR SA FR1 - E-UTRA RSRP absolute measurement accuracy for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.1 Test purpose
To verify that the E-UTRAN RSRP measurement accuracy is within the specified limits. This test will verify the requirements in TS 38.133 [6] clause 10.2A.2 for SA inter-RAT E-UTRAN RSRP measurements.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.2 Test applicability
This test applies to all types of NR RedCap UEs with 2Rx from Release 17 onwards and supporting E-UTRA.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.5.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.5.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.5.1.4.1 with following exceptions: - Table 6.7.5.1.4.1-1 is replaced by Table 16.7.5.2.4.1-1; - Table 6.7.5.1.4.1-2 is replaced by Table 16.7.5.2.4.1-2; Table 16.7.5.2.4.1-1: Supported test configurations Configuration Description 16.7.5.2-1 NR 15 kHz SSB SCS, 10 MHz b...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.5.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.4.3 Message contents
Same as the message contents given in 6.7.5.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.5.2.5 Test requirement
Same as the test requirements given in clause 6.7.5.1.5 with following exceptions: - Table 6.7.5.1.5-1 is replaced by Table 16.7.5.2.5-1; - Table 6.7.5.1.5-2 is replaced by Table 16.7.5.2.5-2; - Table 6.7.5.1.5-3 is replaced by Table 16.7.5.2.5-3; Table 16.7.5.2.5-1: NR Cell specific test parameters (Cell 1) Parameter ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6 E-UTRAN RSRQ for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.0.1 E-UTRAN RSRQ absolute accuracy
When RedCap UE is capable of 2Rx, the minimum requirements given in clause 6.7.6.0.1 shall apply. When RedCap UE is only required to support 1Rx, the requirements for absolute accuracy of RSRQ in this clause apply to a cell that has different carrier frequency from the serving cell. The accuracy requirements in Table 1...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1 NR SA FR1 - E-UTRA RSRQ absolute measurement accuracy for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.1 Test purpose
To verify that the E-UTRAN RSRQ measurement accuracy is within the specified limits. This test will verify the requirements in TS 38.133 [6] clause 10.2A.2 for SA inter-RAT E-UTRAN RSRP measurements.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.2 Test applicability
This test applies to all types of NR RedCap UEs with 1Rx from Release 17 onwards and supporting E-UTRA.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.6.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.6.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.6.1.4.1 with following exceptions: - Table 6.7.6.1.4.1-1 is replaced by Table 16.7.6.1.4.1-1; - Table 6.7.6.1.4.1-2 is replaced by Table 16.7.6.1.4.1-2; Table 16.7.6.1.4.1-1: Supported test configurations Configuration Description 16.7.6.1-1 NR 15 kHz SSB SCS, 10 MHz b...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.6.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.4.3 Message contents
Same as the message contents given in 6.7.6.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.1.5 Test requirement
Same as the test requirements given in clause 6.7.6.1.5 with following exceptions: - Table 6.7.6.1.5-1 is replaced by Table 16.7.6.1.5-1; - Table 6.7.6.1.5-2 is replaced by Table 16.7.6.1.5-2; - Table 6.7.6.1.5-3 is replaced by Table 16.7.6.1.5-3; Table 16.7.6.1.5-1: NR Cell specific test parameters (Cell 1) Parameter ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2 NR SA FR1 - E-UTRA RSRQ absolute measurement accuracy for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.1 Test purpose
To verify that the E-UTRAN RSRQ measurement accuracy is within the specified limits. This test will verify the requirements in TS 38.133 [6] clause 10.2A.2 for SA inter-RAT E-UTRAN RSRP measurements.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.2 Test applicability
This test applies to all types of NR RedCap UEs with 2Rx from Release 17 onwards and supporting E-UTRA.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.6.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.6.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.6.1.4.1 with following exceptions: - Table 6.7.6.1.4.1-1 is replaced by Table 16.7.6.2.4.1-1; - Table 6.7.6.1.4.1-2 is replaced by Table 16.7.6.2.4.1-2; Table 16.7.6.2.4.1-1: Supported test configurations Configuration Description 16.7.6.2-1 NR 15 kHz SSB SCS, 10 MHz b...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.6.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.4.3 Message contents
Same as the message contents given in 6.7.6.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.6.2.5 Test requirement
Same as the test requirements given in clause 6.7.6.1.5 with following exceptions: - Table 6.7.6.1.5-1 is replaced by Table 16.7.6.2.5-1; - Table 6.7.6.1.5-2 is replaced by Table 16.7.6.2.5-2; - Table 6.7.6.1.5-3 is replaced by Table 16.7.6.2.5-3; Table 16.7.6.2.5-1: NR Cell specific test parameters (Cell 1) Parameter ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17 NR standalone tests in FR2 for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1 RRC_IDLE state mobility for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1 NR cell re-selection for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.0.1 Minimum conformance requirements for intra-frequency cell re-selection for RedCap
The UE shall be able to identify new intra-frequency cells and perform SS-RSRP and SS-RSRQ measurements of the identified intra-frequency cells without an explicit intra-frequency neighbour list containing physical layer cell identities. The UE shall be able to evaluate whether a newly detectable intra-frequency cell m...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.0.2 Minimum conformance requirements for inter-frequency cell re-selection for RedCap
The UE shall be able to identify new inter-frequency cells and perform SS-RSRP or SS-RSRQ measurements of identified inter-frequency cells if carrier frequency information is provided by the serving cell, even if no explicit neighbour list with physical layer cell identities is provided. If Srxlev > SnonIntraSearchP an...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.0.3 Minimum conformance requirements for intra-frequency cell re-selection for RedCap UE configured with stationary relaxed measurement criterion
This clause contains requirements for measurements on intra-frequency NR cells provided that: - UE is configured with stationaryMobilityEvaluation [2] criterion and UE has fulfilled that criterion, or - UE is configured with both stationaryMobilityEvaluation [2] criterion and cellEdgeEvaluationWhileStationary [2] crite...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.0.4 Minimum conformance requirements for inter-frequency cell re-selection for RedCap UE configured with stationary relaxed measurement criterion
This clause contains requirements for measurements on inter-frequency NR cells provided that: - UE is configured with stationaryMobilityEvaluation [2] criterion and UE has fulfilled that criterion, or - UE is configured with both stationaryMobilityEvaluation [2] criterion and cellEdgeEvaluationWhileStationary [2] crite...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1 NR SA FR2 Cell reselection for 2 Rx UE
Editor’s Note: This test case is complete for the following configurations: • Test frequency f ≤ 40.8 GHz. • UE PC3 This test case is incomplete for Test frequency f > 40.8 GHz This test case is incomplete for UE power class other than PC3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.1 Test purpose
The purpose of this test is to verify the requirement for the NR SA intra-frequency cell reselection in FR2 for 2 Rx RedCap UEs. The requirements are specified in TS 38.133 [6] in clause 4.2B.2.3..
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.2 Test applicability
This test applies to all types of NR RedCap UE release 17 and forward.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.3 Minimum conformance requirements
The minimum conformance requirements are defined in clause 17.1.1.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.17.1.1.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 17.1.1.1.4.1-1. Table 17.1.1.1.4.1-1: Supported test configurations for NR SA FR2 Cell reselection to FR2 intra-frequency NR case for 2 Rx Configuration Description 17.1.1.1-1 120 kHz SSB SCS, 100 MHz bandwidth, TDD duplex mode 17.1.1.1-2 240 kHz S...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.4.2 Test procedure
Two cells are deployed in the test, which are one FR2 NR PCell (Cell 1) and an NR neighbour cell (Cell 2) on the same frequency. The test consists of 3 successive time periods, with time duration of T1, T2, and T3 respectively. Only cell 1 is already identified by the UE prior to the start of the test. Cell 1 and cell ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: Table 17.1.1.1.4.3-1: Common Exception messages Default Message Contents Common contents of system information blocks exceptions Table H.2.1-2 Default RRC messages and information elements contents exceptions Table 7.1.1.1.4.3-...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.1.5 Test requirement
Table 17.1.1.1.5-1 defines the primary level settings including test tolerances for NR – E-UTRA cell re-selection test case in AWGN for 2 Rx UE. Table 17.1.1.1.5-1: Cell specific test parameters for NR SA FR2 Cell reselection to FR2 intra-frequency NR case for 2 Rx Parameter Unit Test configuration Cell 1 Cell 2 T1 T2 ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2 NR SA FR2-FR2 Cell reselection for 2 Rx UE
Editor’s Note: This test case is complete for the following configurations: • Test frequency f ≤ 40.8 GHz. • UE PC3 This test case is incomplete for Test frequency f > 40.8 GHz This test case is incomplete for UE power class other than PC3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.1 Test purpose
The purpose of this test is to verify the requirement for the NR SA intra-frequency cell reselection in FR2 for 2 Rx RedCap UEs. The requirements are specified in TS 38.133 [6] in clause 4.2B.2.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.2 Test applicability
This test applies to all types of NR RedCap UE release 17 and forward.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.3 Minimum conformance requirements
The minimum conformance requirements are defined in clause 17.1.1.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.17.1.1.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 17.1.1.2.4.1-1. Table 17.1.1.2.4.1-1: Supported test configurations for NR SA FR2-FR2 Cell reselection to FR2 inter-frequency NR for 2 Rx Configuration Description for serving cell Description for target cell 17.1.1.2-1 120 kHz SSB SCS, 100 MHz ban...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.4.2 Test procedure
Two cells on two RF channels are deployed in the test, which are one FR2 NR PCell (Cell 1) on RF channel 1 and an NR neighbour cell (Cell 2) on RF channel 2. The test consists of 3 successive time periods, with time duration of T1, T2, and T3 respectively. Only cell 1 is already identified by the UE prior to the start ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: Table 17.1.1.2.4.3-1: Common Exception messages Default Message Contents Common contents of system information blocks exceptions Table H.2.2-1 for NR Cell 1 Default RRC messages and information elements contents exceptions Tabl...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.2.5 Test requirement
Table 17.1.1.2.5-1 defines the primary level settings including test tolerances for NR – E-UTRA cell re-selection test case in AWGN for 2 Rx UE. Table 17.1.1.2.5-1: Cell specific test parameters for NR SA FR2-FR2 Cell reselection to FR2 inter-frequency NR for 2 Rx Parameter Unit Test configuration Cell 1 Cell 2 T1 T2 T...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3 NR SA FR2 Cell reselection for UE fulfilling stationary relaxed measurement criterion for 2 Rx UE
Editor’s Note: This test case is complete for the following configurations: • Test frequency f ≤ 40.8 GHz. • UE PC3 This test case is incomplete for Test frequency f > 40.8 GHz This test case is incomplete for UE power class other than PC3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.1 Test purpose
The purpose of this test is to verify the requirement for the NR SA intra-frequency cell reselection in FR2 for 2 Rx RedCap UEs. The requirements are specified in TS 38.133 [6] in clause 4.2B.2.9.2..
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.2 Test applicability
This test applies to all types of NR RedCap UE release 17 and forward supporting Rel-17 relaxed RRM measurements of neighbour cells in RRC_IDLE/RRC_INACTIVE.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.3 Minimum conformance requirements
The minimum conformance requirements are defined in clause 17.1.1.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.17.1.1.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 17.1.1.3.4.1-1. Table 17.1.1.3.4.1-1: Supported test configurations for NR SA FR2 Cell reselection to FR2 intra-frequency NR for UE fulfilling stationary relaxed measurement criterion for 2 Rx UE Configuration Description 17.1.1.3-1 120 kHz SSB SCS...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.4.2 Test procedure
Two cells are deployed in the test, which are one FR2 NR PCell (Cell 1) and an NR neighbour cell (Cell 2) on the same frequency. The test consists of 2 successive time periods, with time duration of T1, T2 respectively. Both cell 1 and cell2 are already identified by the UE prior to the start of the test. Cell 1 and ce...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: Table 17.1.1.3.4.3-1: Common Exception messages Default Message Contents Common contents of system information blocks exceptions Table H.2.1-2 Default RRC messages and information elements contents exceptions Table 17.1.1.3.4.3...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.3.5 Test requirement
Table 17.1.1.3.5-1 defines the primary level settings including test tolerances for NR – E-UTRA cell re-selection test case in AWGN for UE fulfilling stationary relaxed measurement criterion for 2 Rx UE. Table 17.1.1.3.5-1: Cell specific test parameters for NR SA FR2 Cell reselection to FR2 intra-frequency NR for UE fu...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4 NR SA FR2-FR2 Cell reselection for UE fulfilling stationary mobility relaxed measurement criterion for 2 Rx UE
Editor’s Note: This test case is complete for the following configurations: • Test frequency f ≤ 40.8 GHz. • UE PC3 This test case is incomplete for Test frequency f > 40.8 GHz This test case is incomplete for UE power class other than PC3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.1 Test purpose
The purpose of this test is to verify the requirement for the NR SA intra-frequency cell reselection in FR2 for 2 Rx RedCap UEs. The requirements are specified in TS 38.133 [6] in clause 4.2B.2.10.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.2 Test applicability
This test applies to all types of NR RedCap UE release 17 and forward supporting Rel-17 relaxed RRM measurements of neighbour cells in RRC_IDLE/RRC_INACTIVE.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.3 Minimum conformance requirements
The minimum conformance requirements are defined in clause 17.1.1.0.4. The normative reference for this requirement is TS 38.133 [6] clause A.17.1.1.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 17.1.1.4.4.1-1. Table 17.1.1.4.4.1-1: Supported test configurations for NR SA FR2-FR2 Cell reselection to FR2 inter-frequency NR for UE fulfilling stationary mobility relaxed measurement criterion for 2 Rx UE Configuration Description for serving c...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.4.2 Test procedure
The test consists of one active cell and one neighbour cell on two different NR RF channels. The UE is requested to monitor the neighbouring cell on one of the NR carriers. The test consists of two successive time periods, with time duration of T1, T2 respectively. Both Cell 1 and Cell 2 are already identified by the U...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: Table 17.1.1.5.4.3-1: Common Exception messages Default Message Contents Common contents of system information blocks exceptions Default RRC messages and information elements contents exceptions Table 17.1.1.5.4.3-2: RACH-Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.1.1.4.5 Test requirement
Table 17.1.1.4.5-1 defines the primary level settings including test tolerances for NR – E-UTRA cell re-selection test case in AWGN for UE fulfilling stationary relaxed measurement criterion for 2 Rx UE. Table 17.1.1.4.5-1: Cell specific test parameters for NR SA FR2-FR2 Cell reselection to FR2 inter-frequency NR for U...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2 RRC_INACTIVE state mobility for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1 Configured Grant based Small Data Transmissions for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.0.1 Minimum conformance requirements for TA validation using CG-SDT
The requirements in this clause are applicable when the UE is configured with timing alignment (TA) validation using cg-SDT-RSRP-ChangeThreshold for transmitting in uplink using CG-SDT as specified in TS 38.331 [13]. The requirements in this clause are applicable for the UE performing small data tranmissions using conf...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1 NR SA FR2 TA validation for CG-SDT for 2 Rx UE
Editor’s Note: This test case is incomplete in following aspects: - Test procedure needs further updates; - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.1 Test purpose
To verify that the UE properly perform TA validation for CG-SDT transmission as specified in TS 38.133 [6] clause 5.2B.2.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.2 Test applicability
This test applies to all types of NR RedCap UE with 2Rx from Release 17 onwards and supporting CG-SDT.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 17.2.1.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.17.2.1.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.4.1 Initial conditions
Same as the initial conditions given in clause 7.2.1.1.4.1 with following exceptions: - Table 7.2.1.1.4.1-1 is replaced by Table 17.2.1.1.4.1-1; - Table 7.2.1.1.4.1-2 is replaced by Table 17.2.1.1.4.1-2; - Table 7.2.1.1.4.1-3 is replaced by Table 17.2.1.1.4.1-3; Table 17.2.1.1.4.1-1: Supported test configurations Table...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.4.2 Test procedure
Same as the test procedure given in clause 7.2.1.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.4.3 Message contents
Same as the message contents given in 7.2.1.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.2.1.1.5 Test requirements
Same as the test requirements given in clause 7.2.1.1.5 with following exceptions: - Table 7.2.1.1.5-1 is replaced by Table 17.2.1.1.5-1. Table 17.2.1.1.5-1: Cell-specific test parameters (NR Cell 1) Parameter Unit Test 1 T1 T2 T3 T4 T5 AoA setup Setup 1 defined in A.3.15 Assumption for UE beams Note 4 Rough EPRE ratio...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.3 RRC_CONNECTED state mobility for RedCap