hash stringlengths 32 32 | doc_id stringlengths 5 12 | section stringlengths 5 1.47k | content stringlengths 0 6.67M |
|---|---|---|---|
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.4.6.2 Configuration for DC | Table 6.4.6.2-1: Intra-band non-contiguous EN-DC configurations
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A_n2A
DC_2A_n2A2
2A
n2A
NOTE2: Only single switched UL is supported |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.4.6.3 Maximum output power for DC | Table 6.4.6.3-1: Maximum output power for Intra-band non-contiguous EN-DC
DC configuration
Power class 2
(dBm)
Tolerance
(dB)
Power class 3
(dBm)
Tolerance
(dB)
DC_2A_n2A2
23
+2/-3
NOTE 2: Only single switched UL is supported |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.4.6.4 Spurious emission band UE co-existence for DC | Note that only Single Tx Switched UL mode is supported for this combination, no spurious emission band UE co-existence requirement is needed |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.4.6.5 MSD analysis for DC | Note that only Single Tx Switched UL mode is supported for this combination, no MSD requirement is needed
6.4.6.6 ∆RIBNC values
The delta R IBNC values for intra-band non-contiguous EN-DC DC_2_n2 are same as for CA_2A-2A in TS 36.101 and are shown in table below.
Table 6.4.6.6-1: Intra-band non-contiguous EN-DC with on... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.4.6.7 MPR, AMPR requirements | Note that only Single Tx Switched UL mode is supported for this combination, no MPR or A-MPR requirement is needed |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5 NR-U related EN-DC combinations | Editor’s Note: During RAN#87e, the following proposal is endorsed:
Carry on with NR-U core requirements with emphasis on generic requirements. For the NR-U combinations captured in the current NR-U WID, the TPs will be handled into the corresponding Rel-16 band combination baskets TR. Target a limited set of those band... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.1 DC_2_n46 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.1.1 Operating bands for DC | Table 6.5.1.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2_n46
2
n46
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.1.2 Configuration for DC | Table 6.5.1.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A_n46A
DC_2A_n46A
2A
n46A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.1.3 Maximum output power for DC | Table 6.5.1.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_2A_n46A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.1.4 Spurious emission band UE co-existence for DC | Does not need to be defined for this combination. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.1.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.5.1.5-1
Table 6.5.1.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
1850
1910
5150
5925
2nd harmonics fr... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.1.7 MSD | MSD for DC_2_n46 is proposed to be defined like in table below, where Note 1 in Table 6.5.1.7-1 is derived from Note 5 in TS 36.101 Table 7.3.1A-0eA and Note 2 in Table 6.5.1.7-1 is derived from Note 16 in TS36.101 in Table 7.3.1A-0a. The Table 6.5.1.7-2 is derived from TS36.101 Table 7.3.1A-0eC.
Table 6.5.1.7-1: Refer... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.2 DC_66_n46 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.2.1 Operating bands for DC | Table 6.5.2.1-1: DC band combination of 1 LTE band + 1 NR band
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_66_n46
66
n46
No |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.2.2 Configuration for DC | Table 6.5.2.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_66A_n46A
DC_66A_n46A
66A
n46A |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.2.3 Maximum output power for DC | Table 6.5.2.3-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_66A_n46A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.2.4 Spurious emission band UE co-existence for DC | Does not need to be defined for this combination. |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.2.5 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.5.2.5-1
Table 6.5.2.5-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
1710
1780
5150
5925
2nd harmonics fr... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.2.7 MSD | MSD for DC_66_n46 is proposed to be defined like in table below, where Note 1 in Table 6.5.2.7-1 is derived from Note 5 in TS36.101 Table 7.3.1A-0eA. The Table 6.5.2.7-2 is derived from TS36.101 Table 7.3.1A-0eC. MSD in Table 6.5.2.7-3 is derived from CA_2A-46A.
Table 6.5.2.7-1: Reference sensitivity QPSK PREFSENS (EN-... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.3 DC_48_n46 | |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.3.1 Configuration for DC | Table 6.5.3.1-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
Single UL allowed
DC_48A_n46A
DC_48A_n46A
No
DC_48B_n46A
DC_48B_n46A
No
DC_48C_n46A
DC_48B_n46A
No
DC_48D_n46A
DC_48B_n46A
No
DC_48E_n46A
DC_48B_n46A
No
DC_48A_n46B
DC_48A_n46A
No
DC_48B_n... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.3.2 Maximum output power for DC | Table 6.5.3.2-1: Maximum output power for inter-band EN-DC of 1 LTE band + 1 NR band
DC configuration
Power class 3
(dBm)
Tolerance
(dB)
DC_48A_n46A
23
+2/-3
DC_48B_n46A
23
+2/-3 |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.3.3 Spurious emission band UE co-existence for DC | Table 6.5.3.3-1: Spurious emissions for inter-band EN-DC of 1 LTE band + 1 NR band
E-UTRA and NR DC Configuration
Spurious emission
Protected band
Frequency range (MHz)
Maximum Level (dBm)
MBW (MHz)
NOTE
DC_48_n46
E-UTRA Band 2, 4, 5, 12, 13, 14, 17, 24, 25, 26, 29, 30, 41, 50, 51, 66, 70, 71, 74, 85
“FDL_low”
-
“FDL_h... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.3.4 MSD analysis for DC | For 2UL/2DL UE coexistence study 2nd, 3rd, 4th and 5th order harmonics and 2nd, 3rd, 4th and 5th order intermodulation products were calculated and presented in Table 6.5.3.4-1.
Table 6.5.3.4-1: Harmonic and IMD analysis
UE UL carriers
fx_low
fx_high
fy_low
fy_high
UL frequency (MHz)
5150
5925
3550
3700
2nd harmonics f... |
60867663a50f38ca462c3e99d4cdca20 | 37.716-11-11 | 6.5.3.6 MSD | Reference sensitivity exceptions due to cross band isolation are specified for DC_48_n46 in tables below.
Table 6.5.3.6.1: Reference sensitivity exceptions (MSD) due to cross band isolation for EN-DC in NR FR1
NR Band / Channel bandwidth of the affected DL band / MSD
UL band
DL band
5 MHz
(dB)
10 MHz
(dB)
15 MHz
(dB)
2... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 1 Scope | The present document is a technical report for Dual Connectivity (EN-DC) of 3 LTE bands (3DL/1UL) and 1 NR band (1DL/1UL) under Rel-16 time frame. The purpose is to gather the relevant background information and studies in order to address Dual Connectivity (EN-DC) of 3 LTE band (3DL/1UL) and 1 NR band (1DL/1UL)for the... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 2 References | The following documents contain provisions which, through reference in this text, constitute provisions of the present document.
- References are either specific (identified by date of publication, edition number, version number, etc.) or non‑specific.
- For a specific reference, subsequent revisions do not apply.
- Fo... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 3 Definitions, symbols and abbreviations | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 3.1 Definitions | For the purposes of the present document, the terms and definitions given in TR 21.905 [1] and the following apply.
A term defined in the present document takes precedence over the definition of the same term, if any, in TR 21.905 [1]. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 3.2 Symbols | For the purposes of the present document, the following symbols apply:
ΔRIB,c Allowed reference sensitivity relaxation due to support for inter-band CA operation, for serving cell c.
ΔTIB,c Allowed maximum configured output power relaxation due to support for inter-band CA
FDL_low The lowest frequency of the downlink o... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 3.3 Abbreviations | For the purposes of the present document, the abbreviations given in TR 21.905 [1] and the following apply.
An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in TR 21.905 [1].
BS Base Station
CA Carrier Aggregation
CA_nX-nY Inter-band CA of component ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 4 Background | The present document is a technical report for Dual Connectivity (EN-DC) of 3 LTE band (3DL/1UL) and 1 NR band (1DL/1UL) under Rel-16 time frame. It covers both the UE and BS side. The document is divided in two different parts:
- General part: this part covers BS and UE specific which is band combination independent.... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 4.1 TR Maintenance | A single company is responsible for introducing all approved TPs in the current TR, i.e. TR editor. However, it is the responsibility of the contact person of each band combination to ensure that the TPs related to the band combination have been implemented. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5 EN-DC of 3 LTE band (3DL/1UL) + 1 NR band: Specific Band Combination Part | <Editor’s note: The requirements for specific band combinations shall be described according to the same mannter as specified in TS38.101-3.> |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1 Inter-band EN-DC within FR1 | 5.1.1 DC_1-3-18_n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.1.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-18_n77
CA_1-3-18
n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.1.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-3A-18A_n77A
DC_1A_n77A
DC_3A_n77A
DC_18A_n77A
CA_ 1A-3A-18A
n77
5.1.1.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-1: ΔTIB,c due to EN-DC(four bands)
Inter-band DC Co... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.2.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-18_n78
CA_1-3-18
n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.2.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-3A-18A_n78A
DC_1A_n78A
DC_3A_n78A
DC_18A_n78A
CA_ 1A-3A-18A
n78
5.1.2.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-1: ΔTIB,c due to EN-DC(four bands)
Inter-band DC Co... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.3.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-18_n79
CA_1-3-18
n79 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.3.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-3A-18A_n79A
DC_1A_n79A
DC_3A_n79A
DC_18A_n79A
CA_ 1A-3A-18A
n79
5.1.3.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-1: ΔTIB,c due to EN-DC(four bands)
Inter-band DC Co... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.4.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-41_n77
CA_1-3-41
n77
DC_1-3-41_n77(*)
CA_1-3-41
n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.4.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-3A-41A_n77A
DC_1A_n77A
DC_3A_n77A
DC_41A_n77A
CA_ 1A-3A-41A
n77
DC_1A-3A-41C_n77A
DC_1A_n77A
DC_3A_n77A
DC_41A_n77A
CA_ 1A-3A-41C
n77
DC_1A-3A-41A_n77(2A)
DC_1A_n7... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.5.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-41_n78
CA_1-3-41
n78
DC_1-3-41_n78(*)
CA_1-3-41
n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.5.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-3A-41A_n78A
DC_1A_n78A
DC_3A_n78A
DC_41A_n78A
CA_ 1A-3A-41A
n78
DC_1A-3A-41C_n78A
DC_1A_n78A
DC_3A_n78A
DC_41A_n78A
CA_ 1A-3A-41C
n78
DC_1A-3A-41A_n78(2A)
DC_1A_n7... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.6.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-41_n79
CA_1-3-41
n79 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.6.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-3A-41A_n79A
DC_1A_n79A
DC_3A_n79A
DC_41A_n79A
CA_ 1A-3A-41A
n79
DC_1A-3A-41C_n79A
DC_1A_n79A
DC_3A_n79A
DC_41A_n79A
CA_ 1A-3A-41C
n79
5.1.6.3 ∆TIB and ∆RIB values
... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.7.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-41-42_n77
CA_3-41-42
n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.7.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_3A-41A-42A_n77A
DC_3A_n77A
DC_41A_n77A
CA_ 3A-41A-42A
n77
DC_3A-41C-42A_n77A
DC_3A_n77A
DC_41A_n77A
CA_ 3A-41A-42A
n77
DC_3A-41A-42C_n77A
DC_3A_n77A
DC_41A_n77A
CA_ 3... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.8.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-41-42_n78
CA_3-41-42
n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.8.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_3A-41A-42A_n78A
DC_3A_n78A
DC_41A_n78A
CA_ 3A-41A-42A
n78
DC_3A-41C-42A_n78A
DC_3A_n78A
DC_41A_n78A
CA_ 3A-41A-42A
n78
DC_3A-41A-42C_n78A
DC_3A_n78A
DC_41A_n78A
CA_ 3... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.9.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-41-42_n79
CA_3-41-42
n79 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.9.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_3A-41A-42A_n79A
DC_3A_n79A
DC_41A_n79A
CA_ 3A-41A-42A
n79
DC_3A-41C-42A_n79A
DC_3A_n79A
DC_41A_n79A
CA_ 3A-41A-42A
n79
DC_3A-41A-42C_n79A
DC_3A_n79A
DC_41A_n79A
CA_ 3... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.10 DC_1-3-7_n78 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.10.1 Operating bands for DC | Table 5.1.10.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-7_n78
CA_1-3-7
n78
DC_3_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.10.2 Channel bandwidths per operating band for DC | Table 5.1.10.2-1 Inter-band EN-DC configurations (four bands)
EN-DC configuration
Uplink EN-DC configuration
E-UTRA CA configuration
NR band
DC_1A-3A-7C_n78A
DC_1A_n78A
DC_3A_n78A
DC_7A_n78A
DC_7C_n78A
CA_ 1A-3A-7C
n78
DC_1A-3C-7C_n78A
DC_1A_n78A
DC_3A_n78A
DC_3C_n78A DC_7A_n78A
DC_7C_n78A
CA_ 1A-3C-7C
n78
DC_1A-3A-7A_... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.10.3 Co-existence studies | Co-existence was studied for DC_1A-3A-7A_n78A in Rel-15 and the results are captured in 37.863-03-01. No further studies are needed for DC_1-3-7_n78.
5.1.10.4 ∆TIB and ∆RIB values
For DC_1-3-7_n78 the TIB,c and RIB values are same as DC_1A-3A-7A_n78A given in the tables below.
Table 5.1.10.4-1: ΔTIB,c
Inter-band DC C... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.10.5 REFSENS | No additional MSD requirements need to be defined for these dual connectivity configurations. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.11 DC_2A-66A-(n)71AA | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.11.1 Operating bands for EN-DC | Table 5.1.11.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-66_(n)71
CA_2-66-71
n71
No1
NOTE 1: For UE(s) supporting dynamic power sharing it is mandatory to do dual simultaneous UL. For UE(s) not supporting dynamic power sharing single UL is allowed. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.11.2 Configuration for EN-DC | Table 5.1.11.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR configuration
DC_2A-66A-(n)71AA
DC_2A_n71A
DC_66A_n71A
CA_2A-66A_71A
n71A
5.1.11.3 ∆TIB and ∆RIB values
∆TIB and ∆RIB values for DC_2_66_n71 are already specified in TS 38.10... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.11.4 REFSENS requirements | REFSENS exceptions needed for DC_2A-(n)71AA due to band 71 uplink harmonic into band 2 is already specified in Table 7.3B.2.3.1-1 of TS 38.101-3. Impact of contiguous intraband EN-DC operation on band 71 on REFSENS is already specified in Table 7.3B.2.1-1 of TS 38.101-3. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.12 DC_1-5-41_n79 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.12.1 Operating bands for EN-DC | Table 5.1.12.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-5-41_n79
CA_1-5-41
n79
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.12.2 Configurations for EN-DC | Table 5.1.12.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-5A-41A_n79A
DC_1A_n79A
DC_5A_n79A
DC_41A_n79A
CA_1A-5A-41A
n79A
5.1.12.3 ∆TIB and ∆RIB values
For DC_1A-5A-41A_n79A, the TIB,c and RIB,c values are given i... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.12.4 REFSENS requirements | Co-existence study for DC_1-5-41_n79 was covered by the studies for the fallback modes of DC_1-5_n79, DC_1-41_n79 and DC_5-41_n79.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.13 DC_3-5-41_n79 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.13.1 Operating bands for EN-DC | Table 5.1.13.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_3-5-41_n79
CA_3-5-41
n79
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.13.2 Configurations for EN-DC | Table 5.1.13.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3A-5A-41A_n79A
DC_3A_n79A
DC_5A_n79A
DC_41A_n79A
CA_3A-5A-41A
n79A
5.1.13.3 ∆TIB and ∆RIB values
For DC_3A-5A-41A_n79A, the TIB,c and RIB,c values are given i... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.13.4 REFSENS requirements | Co-existence study for DC_3-5-41_n79 was covered by the studies for the fallback modes of DC_3-5_n79, DC_3-41_n79 and DC_5-41_n79.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.14 DC_1-3-5_n79 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.14.1 Operating bands for EN-DC | Table 5.1.14.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-5_n79
CA_1-3-5
n79
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.14.2 Configurations for EN-DC | Table 5.1.14.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-5A_n79A
DC_1A_n79A
DC_3A_n79A
DC_5A_n79A
CA_1A-3A-5A
n79A
5.1.14.3 ∆TIB and ∆RIB values
For DC_1A-3A-5A_n79A, the TIB,c and RIB,c values are given in th... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.14.4 REFSENS requirements | Co-existence study for DC_1-3-5_n79 was covered by the studies for the fallback modes of DC_1-3_n79, DC_1-5_n79 and DC_3-5_n79.
No additional MSD requirement need to be defined for this dual connectivity configuration.
5.1.15 DC_1-18-42_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.15.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-18-42_n78
CA_1-18-42
n78
no |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.15.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-18A-42A_n78A
DC_1A_n78A
DC_18A_n78A
CA_ 1A-18A-42A
n78
DC_1A-18A-42C_n78A
DC_1A_n78A
DC_18A_n78A
CA_ 1A-18A-42C
n78
5.1.15.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.16.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-18-42_n78
CA_3-18-42
n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.16.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_3A-18A-42A_n78A
DC_3A_n78A
DC_18A_n78A
CA_ 3A-18A-42A
n78
DC_3A-18A-42C_n78A
DC_3A_n78A
DC_18A_n78A
CA_ 3A-18A-42C
n78
5.1.16.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.17.1 Operating bands for DC_1-8-20_n78 | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-8-20_n781
CA_1-8-20
n78
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.17.2 Configurations for DC_1-8-20_n78 | Table 5.5B.4.3-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-8A-20A_n78A
DC_1A_n78A
DC_8A_n78A
DC_20A_n78A
CA 1A-8A-20A
n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.17.3 Co-existence Studies | Co-existence studies of this 4DL/2UL DC configuration are already covered in the constituent fall-back modes. Therefore, no additional studies are needed.
5.1.17.4 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-1: ΔTIB,c due to EN-DC (four bands)
Inter-band DC Configuration
E-UTRA and NR Band
ΔTIB,c [dB]
DC_1-8-20_n78A
1
0.3
... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.17.5 REFSENS requirements | REFSENS requirements of this 4DL/2UL DC configuration are already covered by constituent fall-back modes. Therefore, no additional REFSENS requirements are needed.
5.1.18 DC_3-8-20_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.18.1 Operating bands for DC_3-8-20_n78 | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-8-20_n781
CA_1-8-20
n78
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.18.2 Configurations for DC_3-8-20_n78 | Table 5.5B.4.3-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3A-8A-20A_n78A
DC_3A_n78A
DC_8A_n78A
DC_20A_n78A
CA 3A-8A-20A
n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.18.3 Co-existence Studies | Co-existence studies of this 4DL/2UL DC configuration are already covered in the constituent fall-back modes. Therefore, no additional studies are needed.
5.1.18.4 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-1: ΔTIB,c due to EN-DC (four bands)
Inter-band DC Configuration
E-UTRA and NR Band
ΔTIB,c [dB]
DC_3-8-20_n78A
3
0.6
... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.18.5 REFSENS requirements | REFSENS requirements of this 4DL/2UL DC configuration are already covered by constituent fall-back modes. Therefore, no additional REFSENS requirements are needed.
5.1.19 DC_3-18-42_n79 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.19.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-18-42_n79
CA_3-18-42
n79
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.19.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_3A-18A-42A_n79A
DC_3A_n79A
DC_18A_n79A
CA_ 3A-18A-42A
n79
DC_3A-18A-42C_n79A
DC_3A_n79A
DC_18A_n79A
CA_ 3A-18A-42C
n79
5.1.19.3 ∆TIB and ∆RIB values
The same values o... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.20.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-18-42_n77
CA_3-18-42
n77
DC_3_n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.20.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_3A-18A-42A_n77A
DC_3A_n77A
DC_18A_n77A
CA_ 3A-18A-42A
n77
DC_3A-18A-42C_n77A
DC_3A_n77A
DC_18A_n77A
CA_ 3A-18A-42C
n77
5.1.20.3 ∆TIB and ∆RIB values
The same values o... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.21.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-18-42_n79
CA_1-18-42
n79
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.21.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-18A-42A_n79A
DC_1A_n79A
DC_18A_n79A
CA_ 1A-18A-42A
n79
DC_1A-18A-42C_n79A
DC_1A_n79A
DC_18A_n79A
CA_ 1A-18A-42C
n79
5.1.21.3 ∆TIB and ∆RIB values
The same values o... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.22.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-18-42_n77
CA_1-18-42
n77
DC_1_n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.22.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-18A-42A_n77A
DC_1A_n77A
DC_18A_n77A
CA_ 1A-18A-42A
n77
DC_1A-18A-42C_n77A
DC_1A_n77A
DC_18A_n77A
CA_ 1A-18A-42C
n77
5.1.22.3 ∆TIB and ∆RIB values
The same values o... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.23 DC_1A-3C-28A_n78A_BCS0 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.23.1 Operating bands for DC | Table 5.1.23.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-28_n781
CA_1-3-28
n78
DC_3_n78
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.23.2 Configuration for DC | Table 5.1.23.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3C-28A_n78A
DC_1A_n78A
DC_3A_n78A
DC_28A_n78A
CA_1A-3C-28A
n78A
5.1.23.3 ∆TIB and ∆RIB values
For DC_1-3-28_n78 the TIB,c and RIB,c values ar... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.23.4 REFSENS requirements | No further MSD are needed to be specified for DC_1A-3C-28A_n78A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.24 DC_1A-7A-28A_n78A_BCS0 | DC_1A-7C-28A_n78A_BCS0 |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.