command
stringlengths
2
75
syntax
stringlengths
0
289k
hierarchy_level
stringlengths
0
6.91k
description
stringlengths
0
45.2k
options
listlengths
0
499
required_privilege_level
stringlengths
0
330k
release_information
stringlengths
0
3.14k
related_documentation
listlengths
0
22
show oam ethernet connectivity-fault-management forwarding-state
show oam ethernet connectivity-fault-management forwarding-state interface interface-name | instance instance-name brief | detail | extensive
Display IEEE 802.1ag Operation, Administration, and Management (OAM) connectivity fault management forwarding state information for Ethernet interfaces.
[ { "name": "interface interface-name", "desc": "Display forwarding state information for the specified Ethernet interface only." }, { "name": "instance instance-name", "desc": "Display forwarding state information for the specified forwarding instance only." }, { "name": "brief | detail |...
view Output Fields Table 977 on page 23538 lists the output fields for the show oam ethernet connectivity-fault-management forwarding-state command. Output fields are listed in the approximate order in which they appear. Table 977: show oam ethernet connectivity-fault-management forwarding-state Output Fields Field Nam...
Command introduced in Junos OS Release 8.4.
[]
show oam ethernet connectivity-fault-management interfaces
show oam ethernet connectivity-fault-management interfaces ethernet-interface-name level md-level brief | detail | extensive
On M7i and M10i routers with Enhanced CFEB (CFEB-E), and on M320, MX Series, ACX Series, T320, and T640 routers, display IEEE 802.1ag Operation, Administration, and Management (OAM) connectivity fault management (CFM) database information for Ethernet interfaces. In addition, for Ethernet interfaces on MX Series router...
[ { "name": "brief | detail | extensive", "desc": "(Optional) Specified level of output." }, { "name": "ethernet-interface-name", "desc": "(Optional) CFM information only for CFM entities attached to the specified Ethernet interface." }, { "name": "level md-level", "desc": "(Optional) ...
view Output Fields Table 978 on page 23544 lists the output fields for the show oam ethernet connectivity-fault-management interfaces command. Output fields are listed in the approximate order in which they appear. Table 978: show oam ethernet connectivity-fault-management interfaces Output Fields Field Name Field Desc...
Command introduced in Junos OS Release 8.4. Support for ITU-T Y.1731 frame delay measurement added in Junos OS Release 9.5. Support for ITU-T Y.1731 Ethernet synthetic frame loss measurement (ETH-SLM) added in Junos OS Release 13.2 for ACX Series and MX Series routers.
[ "Ethernet Alarm Indication", "show oam ethernet connectivity-fault-management linktrace path-" ]
database
show oam ethernet connectivity-fault-management linktrace path-database mac-address maintenance-association ma-name maintenance-domain md-name
On M320, MX Series, T320, and T640 routers, display IEEE 802.1ag Operation, Administration, and Management (OAM) connectivity fault management maintenance linktrace database information.
[ { "name": "mac-address", "desc": "Display connectivity fault management path database information for the specified MAC address of the remote host." }, { "name": "maintenance-association", "desc": "" }, { "name": "ma-name", "desc": "Display connectivity fault management path database...
view Output Fields Table 979 on page 23560 lists the output fields for the show oam ethernet connectivity-fault-management linktrace path-database command. Output fields are listed in the approximate order in which they appear. Table 979: show oam ethernet connectivity-fault-management linktrace path-database Output F...
Command introduced in Junos OS Release 9.0.
[]
show oam ethernet connectivity-fault-management loss-statistics
show oam ethernet connectivity-fault-management loss-statistics maintenance-domain md-name maintenance-association ma-name <count entry-count> <local-mep local-mep-id> <remote-mep remote-mep-id>
On MX Series and ACX series routers with Ethernet interfaces, display ETH-LM statistics for on-demand mode only.
[ { "name": "maintenance-domain md-name", "desc": "Name of an existing CFM maintenance domain." }, { "name": "maintenance-association", "desc": "" }, { "name": "ma-name", "desc": "Name of an existing CFM maintenance association." }, { "name": "count entry-count", "desc": "(...
view Output Fields Table 980 on page 23563 lists the output fields for the show oam ethernet connectivity-fault-management loss- statistics command. Output fields are listed in the approximate order in which they appear. Table 980: show oam ethernet connectivity-fault-management loss-statistics Output Fields Output Fie...
Command introduced in Junos OS Release 11.1.
[]
show oam ethernet connectivity-fault-management mep-database
show oam ethernet connectivity-fault-management mep-database maintenance-domain domain-name maintenance-association ma-name <local-mep local-mep-id> <remote-mep remote-mep-id> extensive
On M7i and M10i routers with Enhanced CFEB (CFEB-E), and on M320, M120, MX Series, ACX Series, T320, and T640 routers, display IEEE 802.1ag Operation, Administration, and Management (OAM) connectivity fault management (CFM) database information for CFM maintenance association end points (MEPs) in a CFM session. In addi...
[ { "name": "maintenance-association ma-name", "desc": "Display connectivity fault management information for the specified maintenance association." }, { "name": "maintenance-domain domain-name", "desc": "Display connectivity fault management information for the specified maintenance domain." }...
view Output Fields Table 981 on page 23569 lists the output fields for the show oam ethernet connectivity-fault-management mep- database command. Output fields are listed in the approximate order in which they appear. Table 981: show oam ethernet connectivity-fault-management mep-database Output Fields Field Name Field...
Command introduced in Junos OS Release 8.4. Support for ITU-T Y.1731 frame delay measurement added in Junos OS Release 9.5. Support for ITU-T Y.1731 synthetic frame loss measurement added in Junos OS Release 13.2 for MX Series routers. Support for ITU-T Y.1731 ethernet expected defect function (ETH-ED) added in Junos O...
[]
show oam ethernet connectivity-fault-management mep-statistics
show oam ethernet connectivity-fault-management mep-statistics maintenance-domain md-name maintenance-association ma-name <mep mep-id> <remote-mep remote-mep-id> <count entry-count>
On MX Series and ACX Series routers and EX Series switches with Ethernet interfaces, display ETH-DM statistics and ETH-DM frame counts. For Ethernet interfaces on MX Series routers, display any ITU-T Y.1731 synthetic frame loss measurement (ETH-SLM) statistics and frame counts.
[ { "name": "maintenance-domain", "desc": "" }, { "name": "md-name", "desc": "Name of an existing CFM maintenance domain." }, { "name": "maintenance-association", "desc": "" }, { "name": "ma-name", "desc": "Name of an existing CFM maintenance association." }, { "nam...
view Output Fields Table 982 on page 23586 lists the output fields for the show oam ethernet connectivity-fault-management mep- statistics command. Output fields are listed in the approximate order in which they appear. Table 982: show oam ethernet connectivity-fault-management delay-statistics and mep-statistics Outpu...
Command introduced in Junos OS Release 9.5. Support for ITU-T Y.1731 Ethernet synthetic frame loss measurement (ETH-SLM) added in Junos OS Release 13.2 for MX Series routers.
[]
show oam ethernet connectivity-fault-management mip
show oam ethernet connectivity-fault-management mip <qualifier>
Display all the maintenance association intermediate points (MIPs) created in the system. Specify qualifiers to display specific MIPs.
[ { "name": "qualifier", "desc": "(Optional) Display the specified MIP." } ]
view Output Fields Table 983 on page 23602 lists the output fields for the show oam ethernet connectivity-fault-management mip command. Output fields are listed in the approximate order in which they appear. Table 983: show oam ethernet connectivity-fault-management mip Output Fields Field Name Field Description MIP in...
Command introduced in Junos OS Release 10.2.
[]
show oam ethernet connectivity-fault-management path-database
show oam ethernet connectivity-fault-management path-database <host-mac-address> <maintenance-association ma-name> <maintenance-domain domain-name>
On M7i and M10i with Enhanced CFEB (CFEB-E), M320, MX Series, ACX Series, T320, and T640 routers, display IEEE 802.1ag Operation, Administration, and Management (OAM) connectivity fault management path database information for a host configured with an MEP.
[ { "name": "host-mac-address", "desc": "(Optional) Display connectivity fault management path database information for a specified Ethernet host." }, { "name": "maintenance-association", "desc": "" }, { "name": "ma-name", "desc": "(Optional) Display connectivity fault management path ...
view Output Fields No Link Title lists the output fields for the show oam ethernet connectivity- fault-management path-database command. Output fields are listed in the approximate order in which they appear. Table 984: show oam ethernet connectivity-fault-management linktrace path-database Output Fields Field Name Fie...
Command introduced in Junos OS Release 8.4.
[]
show oam ethernet connectivity-fault-management policer
show oam ethernet connectivity-fault-management policer <maintenance-domain md-name> <maintenance- association ma-name>
On M120, M320, MX Series, T320, and T640 routers displays connectivity-fault-management policer statistics.
[ { "name": "maintenance-domain", "desc": "" }, { "name": "md-name", "desc": "Name of an existing CFM maintenance domain. If this option is not specified, policer statistics are displayed for all maintenance associations for all maintenance domains." }, { "name": "maintenance-association m...
view Output Fields Table 985 on page 23608 lists the output fields for the show oam ethernet connectivity-fault-management policer command. Output fields are listed in the approximate order in which they appear. Table 985: show oam ethernet connectivity-fault-management policer Output Fields Field Name Field Descriptio...
Command introduced in Junos OS Release 10.0.
[]
show oam ethernet connectivity-fault-management sla-iterator-history
show oam ethernet connectivity-fault-management sla-iterator-history <availability> <bin> <delay-measurement> <local-mep local-mep-id> <logical-system logical-system name> <loss-measurement> <maintenance-association maintenance-association-name> <maintenance-domain maintenance-domain-name> <record-number> <remote-mep r...
Display the Ethernet Operation, Administration, and Maintenance (OAM) service-level agreement (SLA) iterator history information.
[ { "name": "availability", "desc": "History availability for SLM/LM measurements." }, { "name": "bin", "desc": "Display history of delay measurement bin statistics." }, { "name": "delay-measurement", "desc": "Display history of delay measurement statistics." }, { "name": "loca...
view Output Fields "Output Fields" on page 23612 lists the output fields for the show oam ethernet connectivity-fault-management sla-iterator-history command. Output fields are listed in the approximate order in which they appear. Table 986: show oam ethernet connectivity-fault-management sla-iterator-history Output F...
Command introduced in Junos OS Release 14.2
[]
show oam ethernet connectivity-fault-management sla-iterator-statistics
show oam ethernet connectivity-fault-management sla-iterator-statistics maintenance-domain md-name maintenance-association ma-name sla-iterator sla-iterator <local-mep local-mep-id> <remote-mep remote-mep-id>
Display the Ethernet Operation, Administration, and Maintenance (OAM) service-level agreement (SLA) iterator statistics.
[ { "name": "maintenance-domain md-name", "desc": "Name of an existing connectivity fault management (CFM) maintenance domain." }, { "name": "maintenance-association ma-name", "desc": "Name of an existing CFM maintenance association." }, { "name": "sla-iterator sla-iterator", "desc": "...
view Output Fields Table 987 on page 23623 lists the output fields for the show oam ethernet connectivity-fault-management sla- iterator-statistics command. Output fields are listed in the approximate order in which they appear. Table 987: show oam ethernet connectivity-fault-management sla-iterator-statistics Output F...
Command introduced in Junos OS Release 11.4 .
[ "Configure an Iterator Profile on a Switch (CLI Procedure)", "show oam ethernet connectivity-fault-management synthetic-loss-" ]
statistics
show oam ethernet connectivity-fault-management synthetic-loss-statistics <local-mep local-mep-id> maintenance-association ma-name <count entry-count> maintenance-domain md-name <remote-mep remote-mep-id>
On MX Series routers with Modular Port Concentrators (MPCs) with Ethernet interfaces, display the on- demand ETH-SLM statistics.
[ { "name": "count entry-count", "desc": "(Optional) Number of entries to display from the statistics table. The range of values is from 1 through 100. The default value is 100." }, { "name": "local-mep local-mep-id", "desc": "(Optional) Numeric identifier of the local MEP. The range of values is ...
view Output Fields Table 988 on page 23637 lists the output fields for the show oam ethernet connectivity-fault-management synthetic-loss-statistics command. Output fields are listed in the approximate order in which they appear. Table 988: show oam ethernet connectivity-fault-management synthetic-loss-statistics Outpu...
Command introduced in Junos OS Release 13.2.
[]
show oam ethernet evc
show oam ethernet evc <evc-id>
On MX Series routers with OAM Ethernet Virtual Connection (EVC) configurations, displays the EVC configuration and status information.
[]
View Output Fields Table 989 on page 23640 lists the output fields for the show oam ethernet evc command. Output fields are listed in the approximate order in which they appear. Table 989: show oam ethernet evc Output Fields Field Name Field Description EVC identifier Header for the EVC information showing the EVC name...
Command introduced in Junos OS Release 9.5.
[]
show oam ethernet fnp interface
show oam ethernet fnp interface <ethernet-interface-name> <routing-instance routing-instance-name>
On MX Series routers with Gigabit Ethernet or aggregated Ethernet PICs, displays OAM Ethernet Failure Notification Protocol (FNP) information for Ethernet interfaces.
[ { "name": "interface-name", "desc": "(Optional) Display Ethernet FNP information for the specified Ethernet interface only." }, { "name": "routing-instance-name", "desc": "(Optional) Display FNP for the specified routing instance." } ]
view Output Fields Table 990 on page 23643 lists the output fields for the show oam ethernet fnp interface command. Output fields are listed in the approximate order in which they appear. Table 990: show oam ethernet fnp interface Output Fields Field Name Field Description Interface Name of the interface for the displ...
Command introduced in Junos OS Release 11.4.
[]
show oam ethernet fnp messages
show oam ethernet fnp messages <interface interface-name> <routing instance routing-instance-name>
On MX Series routers with Gigabit Ethernet or aggregated Ethernet PICs, displays OAM Ethernet Failure Notification Protocol (FNP) messages.
[ { "name": "interface-name", "desc": "(Optional) Display Ethernet FNP messages for the specified Ethernet interface only." }, { "name": "routing-instance-name", "desc": "(Optional) Display FNP messages for the specified routing instance." } ]
view Output Fields Table 991 on page 23645 lists the output fields for the show oam ethernet fnp messages command. Output fields are listed in the approximate order in which they appear. Table 991: show oam ethernet fnp messages Output Fields Field Name Field Description Message from source MAC address The source MAC ...
Command introduced in Junos OS Release 11.4
[]
show oam ethernet fnp status
show oam ethernet fnp status <interface interface-name> <routing instance routing-instance-name>
On MX Series routers with Gigabit Ethernet or aggregated Ethernet PICs, displays OAM Ethernet Failure Notification Protocol (FNP) status.
[ { "name": "interface-name", "desc": "(Optional) Display Ethernet FNP information for the specified Ethernet interface only." }, { "name": "routing-instance-name", "desc": "(Optional) Display FNP for the specified routing instance." } ]
view Output Fields Table 992 on page 23647 lists the output fields for the show oam ethernet fnp status command. Output fields are listed in the approximate order in which they appear. Table 992: show oam ethernet fnp status Output Fields Field Name Field Description FNP interval The time interval between messages. Ta...
Command introduced in Junos OS Release 11.4
[]
show oam ethernet link-fault-management
show oam ethernet link-fault-management <brief | detail> <interface-name>
Display Operation, Administration, and Maintenance (OAM) link fault management (LFM) information for Ethernet interfaces.
[ { "name": "brief | detail", "desc": "(Optional) Display the specified level of output." }, { "name": "interface-name", "desc": "(Optional) Display link fault management information for the specified Ethernet interface only." } ]
view Output Fields Table 993 on page 23650 lists the output fields for the show oam ethernet link-fault-management command. Output fields are listed in the approximate order in which they appear. Table 993: show oam ethernet link-fault-management Output Fields Field Name Field Description Level of Output Status Status...
Statement for SRX Series Firewalls introduced in Junos OS Release 9.5.
[ "clear oam ethernet connectivity-fault-management statistics", "Understanding Ethernet OAM Link Fault Management for SRX Series Services Gateways", "Example: Configuring Ethernet OAM Link Fault Management on a Security Device" ]
show oam ethernet lmi statistics
show oam ethernet lmi statistics <interface interface-name>
On MX Series routers with Gigabit Ethernet or aggregated Ethernet PICs, displays OAM Ethernet Local Management Interface (LMI) statistics.
[ { "name": "interface", "desc": "(Optional) Display LMI statistics for a specified interface." }, { "name": "interface-name", "desc": "(Optional) Display Ethernet LMI information for the specified Ethernet interface only." } ]
view Output Fields Table 994 on page 23660 lists the output fields for the show oam ethernet lmi statistics command. Output fields are listed in the approximate order in which they appear. Table 994: show oam ethernet lmi statistics Output Fields Field Name Field Description Physical interface Name of the interface for...
Command introduced in Junos OS Release 9.5.
[]
show oam ethernet lmi
show oam ethernet lmi (interface <interface-name>)
On routers with Gigabit Ethernet or aggregated Ethernet, and OAM Ethernet Local Management Interface (E-LMI) configuration, display the LMI information for the configured interfaces or optionally for a specified interface. NOTE: On MX Series routers, E-LMI is supported on Gigabit Ethernet (ge), 10-Gigabit Ethernet (xe)...
[ { "name": "interface", "desc": "(Optional) Display LMI information for a specified interface." }, { "name": "interface-name", "desc": "(Optional) Display Ethernet LMI information for the specified interface only." } ]
View Output Fields Table 995 on page 23663 lists the output fields for the show oam ethernet lmi command. Output fields are listed in the approximate order in which they appear. Table 995: show oam ethernet lmi Output Fields Field Name Field Description Physical Interface Header for the EVC information showing the Ethe...
Command introduced in Junos OS Release 9.5.
[]
show oam fabric flow-specification
show oam fabric flow-specification <flow-specification-name>
Display the fabric flow specifications that are configured in a QFabric system Node group.
[ { "name": "flow-specification-name", "desc": "(Optional) Name of a flow specification." } ]
interface—To view this statement in the configuration. interface-control—To add this statement to the configuration. Output Fields Table 996 on page 23665 lists the output fields for the show oam fabric flow-specification command. Output fields are listed in the approximate order in which they appear. Table 996: show o...
Command introduced in Junos OS Release 12.2.
[ "Overview of Internal Fabric Monitoring", "Configuring a Fabric Maintenance Association", "Configuring Flow Specifications" ]
show oam fabric interfaces
show oam fabric interfaces <interface-name> <fabric-maintenance-association fma-name> <brief>
Display the fabric maintenance associations (FMAs) and fabric maintenance endpoints (FMEPs) that are configured in a QFabric system Node group. If you do not specify an interface, display information for an FMA (if one is specified) or all FMAs configured in the Node group.
[ { "name": "brief", "desc": "(Optional) Summarized version of the output." }, { "name": "fabric-maintenance-association fma-name", "desc": "(Optional) Name of a specific FMA." }, { "name": "interface-name", "desc": "(Optional) Name of a specific interface." } ]
interface—To view this statement in the configuration. interface-control—To add this statement to the configuration. Output Fields Table 997 on page 23670 lists the output fields for the show oam fabric interfaces command. Output fields are listed in the approximate order in which they appear. Table 997: show oam fabri...
Command introduced in Junos OS Release 12.2.
[ "Overview of Internal Fabric Monitoring", "Configuring a Fabric Maintenance Association", "Configuring Flow Specifications" ]
show openflow capability
show openflow capability <action | feature | match-condition>
Display support information for OpenFlow features, actions, and match conditions on the Juniper Networks device.
[ { "name": "none", "desc": "Display support information for all OpenFlow capabilities." }, { "name": "action", "desc": "(Optional) Display support information for OpenFlow actions." }, { "name": "feature", "desc": "(Optional) Display support information for OpenFlow features." }, ...
admin Output Fields Table 998 on page 23672 lists the output fields for the show openflow capability command. Output fields are listed in the approximate order in which they appear. Table 998: show openflow capability Output Fields Field Name Field Description Supported Features—Indicates Whether the Juniper Networks D...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands", "OpenFlow Support on Juniper Networks Devices" ]
show openflow controller
show openflow controller <address address> <switch switch-name>
Display OpenFlow controller information and connection status. OpenFlow controllers are configured at the [edit protocols openflow switch switch-name] hierarchy level.
[ { "name": "none", "desc": "Display information about all configured controllers." }, { "name": "address address", "desc": "(Optional) Display information about the controller at the specified IP address." }, { "name": "switch switch-name", "desc": "(Optional) Display information abou...
admin Output Fields Table 999 on page 23681 lists the output fields for the show openflow controller command. Output fields are listed in the approximate order in which they appear. Table 999: show openflow controller Output Fields Field Name Field Description Controller socket Socket on the controller to which the Ope...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands", "OpenFlow Support on Juniper Networks Devices", "Understanding the OpenFlow Version Negotiation Between the Controller and Devices Running", "Junos OS" ]
show openflow filters
show openflow filters <interface interface-name> <switch switch-name>
Display information for filters bound to OpenFlow interfaces.
[ { "name": "none", "desc": "Display information for all filters that are bound to OpenFlow interfaces." }, { "name": "interface interface-name", "desc": "(Optional) Display information for the filter bound to the specified OpenFlow interface. The interface name must include the logical unit numbe...
admin Output Fields Table 1000 on page 23685 lists the output fields for the show openflow filters command. Output fields are listed in the approximate order in which they appear. Table 1000: show openflow filters Output Fields Field Name Field Description Switch Name User-configured identifier for the OpenFlow virtual...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands", "Understanding OpenFlow Flows and Filters on Devices Running Junos OS" ]
show openflow flows
show openflow flows <brief | detail | summary> <flow-id> <switch switch-name>
Display information about traffic flows that match filters on OpenFlow interfaces.
[ { "name": "none", "desc": "(Same as brief) Display information for all flows." }, { "name": "brief | detail | summary", "desc": "(Optional) Display the specified level of output." }, { "name": "flow-id", "desc": "(Optional) Display information only for the specified flow." }, { ...
admin Output Fields Table 1001 on page 23689 lists the output fields for the show openflow flows command. Output fields are listed in the approximate order in which they appear. Table 1001: show openflow flows Output Fields Field Name Field Description Switch Name User-configured identifier for the OpenFlow virtual swi...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands", "OpenFlow Support on Juniper Networks Devices" ]
show openflow groups
show openflow groups <brief | details | summary> <group-id>
Display information about OpenFlow groups. Groups are supported only on Juniper Networks devices running OpenFlow v1.3.1 or later.
[ { "name": "none", "desc": "Display information for all groups." }, { "name": "brief | detail | summary", "desc": "(Optional) Display the specified level of output." }, { "name": "group-id", "desc": "(Optional) Display information about the specified group only." } ]
admin Output Fields Table 1002 on page 23695 describes the output fields for the show openflow groups command. Table 1002 on page 23695 lists the output fields in the approximate order in which they are displayed in the sample output. Table 1002: show openflow groups Output Fields Field Name Field Description Group ID ...
Command introduced in Junos OS Release 14.1X53-D10.
[ "Understanding How the OpenFlow Group Action Works", "OpenFlow Operational Mode Commands" ]
show openflow interfaces
show openflow interfaces <interface-name> <switch switch-name>
Display physical characteristics and status information for interfaces participating in OpenFlow.
[ { "name": "none", "desc": "Display information for all interfaces participating in OpenFlow." }, { "name": "interface-name", "desc": "(Optional) Display information only for the specified interface. Specify the interface" }, { "name": "name including the logical unit number", "desc":...
admin Output Fields Table 1003 on page 23699 lists the output fields for the show openflow interfaces command. Output fields are listed in the approximate order in which they appear. Table 1003: show openflow interfaces Output Fields Field Name Field Description Switch name User-configured identifier for the OpenFlow v...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow statistics flows
show openflow statistics flows <flow-id> <switch switch-name>
Display statistics for OpenFlow flows.
[ { "name": "none", "desc": "Display flow statistics for all flows for all OpenFlow virtual switches." }, { "name": "flow-id", "desc": "(Optional) Display flow statistics only for the specified flow." }, { "name": "switch switch-name", "desc": "(Optional) Display flow statistics only f...
admin Output Fields Table 1004 on page 23704 lists the output fields for the show openflow statistics flows command. Output fields are listed in the approximate order in which they appear. Table 1004: show openflow statistics flows Output Fields Field Name Field Description Switch Name User-configured identifier for th...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow statistics groups
show openflow statistics groups <group-id>
Switch Name User-configured identifier for the OpenFlow virtual switch in which the groups resides. Group ID Unique identifier assigned to the group by the OpenFlow controller. Ref Count Number of flow entries that reference the group. Number of packets (group) Number of packets handled by the group. Number of bytes (g...
[ { "name": "none", "desc": "Display statistics for all groups defined on all OpenFlow virtual switches." }, { "name": "group-id", "desc": "(Optional) Display statistics only for the specified group." } ]
admin Output Fields Table 1005 on page 23709 lists the output fields for the show openflow statistics groups command. Output fields are listed in the approximate order in which they appear. Table 1005: show openflow statistics groups Output Fields Field
Command introduced in Junos OS Release 14.1X53-D10.
[ "Understanding How the OpenFlow Group Action Works", "OpenFlow Operational Mode Commands" ]
show openflow statistics interfaces
show openflow statistics interfaces <switch switch-name>
Display statistics for interfaces participating in OpenFlow.
[ { "name": "none", "desc": "Display statistics for all interfaces participating in OpenFlow for all configured OpenFlow virtual switches." }, { "name": "switch switch-name", "desc": "(Optional) Display statistics only for those interfaces on the specified OpenFlow virtual switch." } ]
admin Output Fields Table 1006 on page 23712 lists the output fields for the show openflow statistics interfaces command. Output fields are listed in the approximate order in which they appear. Table 1006: show openflow statistics interfaces Output Fields Field Name Field Description Switch Name User-configured identif...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow statistics packet
show openflow statistics packet (in | out) <switch switch-name>
Display statistics for packet-in and packet-out (send-packet) actions.
[ { "name": "none", "desc": "Display statistics for all OpenFlow virtual switches." }, { "name": "switch switch-name", "desc": "(Optional) Display statistics only for the specified OpenFlow virtual switch." } ]
admin Output Fields Table 1007 on page 23717 lists the output fields for the show openflow statistics packet command. Output fields are listed in the approximate order in which they appear. Table 1007: show openflow statistics packet Output Fields Field Name Field Description Switch Name User-configured identifier for...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow statistics queue
show openflow statistics queue <interface interface-name>
Display statistics for hardware queues for interfaces participating in OpenFlow.
[ { "name": "none", "desc": "Display queue statistics for all interfaces participating in OpenFlow." }, { "name": "interface", "desc": "" }, { "name": "interface-name", "desc": "(Optional) Display queue statistics only for the specified interface. Specify the" }, { "name": "int...
admin Output Fields Table 1008 on page 23719 lists the output fields for the show openflow statistics queue command. Output fields are listed in the approximate order in which they appear. Table 1008: show openflow statistics queue Output Fields Field Name Field Description Switch Name User-configured identifier for th...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow statistics summary
show openflow statistics summary
Display summary statistics for all installed OpenFlow flow entries for all OpenFlow virtual switches.
[]
admin Output Fields Table 1009 on page 23723 lists the output fields for the show openflow statistics summary command. Output fields are listed in the approximate order in which they appear. Table 1009: show openflow statistics summary Output Fields Field Name Field Description Switch Name User-configured identifier f...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow statistics tables
show openflow statistics tables <switch switch-name>
Display statistics for OpenFlow flow tables.
[ { "name": "none", "desc": "Display statistics for flow tables on all OpenFlow virtual switches." }, { "name": "switch switch-name", "desc": "(Optional) Display statistics only for flow tables on the specified OpenFlow virtual switch." } ]
admin Output Fields Table 1010 on page 23726 lists the output fields for the show openflow statistics tables command. Output fields are listed in the approximate order in which they appear. Table 1010: show openflow statistics tables Output Fields Field Name Field Description Table Name String identifier for the OpenF...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow summary
show openflow summary
Display summary information for OpenFlow including the number of configured virtual switches, controllers, interfaces, and flows.
[]
admin Output Fields Table 1011 on page 23730 lists the output fields for the show openflow summary command. Output fields are listed in the approximate order in which they appear. Table 1011: show openflow summary Output Fields Field Name Field Description Number of switches Total number of configured OpenFlow virtual...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show openflow switch
show openflow switch <switch-name>
Display OpenFlow message statistics for OpenFlow virtual switches.
[ { "name": "none", "desc": "Display information for all OpenFlow virtual switches." }, { "name": "switch switch-name", "desc": "(Optional) Display information only for the specified OpenFlow virtual switch." } ]
admin Output Fields Table 1012 on page 23732 lists the output fields for the show openflow switch command. Output fields are listed in the approximate order in which they appear. Table 1012: show openflow switch Output Fields Field Name Field Description Switch Name User-configured identifier for the OpenFlow virtual ...
Command introduced in Junos OS Release 13.3.
[ "OpenFlow Operational Mode Commands" ]
show ospf context-identifier
show ospf context-identifier <brief | detail> <area area-id> <context-id> <instance instance-name>
Display the context identifier information processed and advertised by Open Shortest Path First (OSPF) for egress protection.
[ { "name": "none", "desc": "Display information about all context identifiers." }, { "name": "brief | detail", "desc": "(Optional) Display the specified level of output." }, { "name": "area area-id", "desc": "(Optional) Display information about the context identifier for the specifie...
view Output Fields Table 1013 on page 23736 lists the output fields for the show ospf context-identifier command. Output fields are listed in the approximate order in which they appear. Table 1013: show ospf context-identifier Output Fields Field Name Field Description Level of Output Context IPv4 address that defines ...
Command introduced in Junos OS Release 10.4.
[ "Junos OS VPNs Library for Routing Devices", "Junos OS VPNs Library for Routing Devices" ]
show ospf database
show ospf database <brief | detail | extensive | summary> <advertising-router (address | self)> <area area-id> <asbrsummary> <external> <instance instance-name> <link-local> <lsa-id lsa-id> <netsummary> <network> <nssa> <opaque-area> <router>
Display the entries in the OSPF version 2 (OSPFv2) link-state database, which contains data about link- state advertisement (LSA) packets.
[ { "name": "none", "desc": "Display standard information about entries in the OSPFv2 link-state database for all routing instances." }, { "name": "brief | detail | extensive |", "desc": "" }, { "name": "summary", "desc": "(Optional) Display the specified level of output." }, { ...
view Output Fields Table 1014 on page 23740 describes the output fields for the show ospf database command. Output fields are listed in the approximate order in which they appear. Table 1014: show ospf database Output Fields Field Name Field Description Level of Output area Area number. Area 0.0.0.0 is the backbone are...
Command introduced before Junos OS Release 7.4. advertising-router self (address | self) option introduced in Junos OS Release 9.5. advertising-router self (address | self) option introduced in Junos OS Release 9.5 for EX Series switches. show ospf database opaque-area extended-link link-addr (link-address) option intr...
[]
show ospf flex-algorithm
show ospf (spring | spf | route) flex-algorithm flex-algorithm-id logical-system (all |logical-system-name)
Display the configured flexible algorithm and the defined parameters.
[ { "name": "flex-algorithm-id", "desc": "Specify the ID of the flex algorithm to view its configured parameters." }, { "name": "logical-system (all | logical-system-name)", "desc": "(Optional) Perform this operation on all logical systems or on a particular logical system." } ]
view Output Fields Table 1015 on page 23750 describes the output fields for the show ospf flex-algorithm command. Output fields are listed in the approximate order in which they appear. Table 1015: show ospf flex-algorithm Output Fields Field Name Field Description flex algorithm Name of the defined flexible algorithm....
Command introduced in Junos OS Release 21.1R1.
[ "Understanding OSPF Flexible Algorithm for Segment Routing", "Example: OSPF Flexible Algorithm", "flex-algorithm (Protocols OSPF)", "definition (Protocols OSPF)" ]
show ospf spring prefix sid map
show ospf spring prefix-sid-map
Displays segment routing mapping server (SRMS) advertisements.
[ { "name": "none", "desc": "Displays the SRMS advertisements and status of the mapping entry. Additional Information The output displays all the prefixes and SIDs. If in case two prefixes have the same SID or single prefix advertised by two multiple mapping servers have different SIDs, it also displays the m...
view Output Fields Table 1 describes the output fields for the show ospf spring prefix-sid-map command. Table 1016: show ospf spring prefix-sid-map Output Fields Field Name Field Description Level of Output SID segment identifier All levels Prefix Destination of the route. All levels Mapping server Name of the mapping ...
Command introduced in Junos OS Release 23.2R1 and Junos OS Evolved Release 23.2R1.
[ "https://www.juniper.net/documentation/us/en/software/junos/ospf/topics/ref/command/show-", "ospf-database.html" ]
show ospf spring sensor info
show ospf spring sensor info
Displays a list of sensors associated with the OSPF Source Packet Routing in Networking (SPRING) route and next hops for segment routing traffic. The command only displays the information related to the sensors and not the traffic statistics.
[ { "name": "none", "desc": "Display the sensor information of an OSPF SPRING route." } ]
view Output Fields Table 1 describes the output fields for the show ospf spring sensor info command. Output fields are listed in the approximate order in which they appear. Table 1017: show ospf spring sensor info Output Fields Field Field Description Sensor-name Represents the router or interface that the sensor is as...
Command introduced in Junos OS Release 23.1R1 and Junos OS Evolved Release 23.1R1.
[ "Overview of Segment Routing Statistics" ]
show ospf spring sid database
show ospf spring sid-database
Displays the segment identifier (SID) database with the prefix and index of native segment routing nodes.
[ { "name": "none", "desc": "Displays the SID database. Additional Information The output displays all the prefixes and all segment identifiers (SIDs). If in any case two prefixes have the same SID or single prefix advertised by two different nodes has different SIDs, it will also display the route-type of th...
view Output Fields Table 1 describes the output fields for the show ospf spring sid-database command. Output fields are listed in the approximate order in which they appear. Table 1018: show ospf spring sid-database Output Fields Field Name Field Description Level of Output SID segment identifier All levels Prefix Dest...
Command introduced in Junos OS Release 23.2R1 and Junos OS Evolved Release 23.2R1.
[ "https://www.juniper.net/documentation/us/en/software/junos/ospf/topics/ref/command/show-", "ospf-database.html" ]
show ospf3 database
show ospf3 database <brief | detail | extensive | summary> <advertising-router (address | self)> <area area-id> <external> <instance instance-name> <inter-area-prefix> <inter-area-router> <intra-area-prefix> <link> <link-local> <lsa-id lsa-id> <network> <nssa> <router>
Display the entries in the OSPF version 3 (OSPFv3) link-state database, which contains data about link- state advertisement (LSA) packets.
[ { "name": "detail extensive", "desc": "" }, { "name": "priority", "desc": "Router priority of the interface attaching the originating routing device to the link." }, { "name": "detail extensive", "desc": "Prefix-count Number of IPv6 address prefixes contained in the LSA. The rest of ...
view Output Fields Table 1019 on page 23768 lists the output fields for the show ospf3 database command. Output fields are listed in the approximate order in which they appear. Table 1019: show ospf3 database Output Fields Field Name Field Description Level of Output OSPF link state database, area area- number Entries ...
Command introduced before Junos OS Release 7.4. realm option introduced in Junos OS Release 9.2. advertising-router (address | self) option introduced in Junos Relase 9.5. advertising-router (address | self) option introduced in Junos OS Release 9.5 for EX Series switches.
[]
show ovsdb commit failures
show ovsdb commit failures <transaction-id>
Display configurations of Open vSwitch Database (OVSDB)-managed Virtual Extensible LANs (VXLANs) and associated logical interfaces that the Juniper Networks switch dynamically configured but was unable to commit. For each OVSDB-managed VXLAN and associated logical interface that you plan to implement in a Junos OS envi...
[ { "name": "none", "desc": "Display information about an erroneous transaction." }, { "name": "transaction-id", "desc": "Display information about the transaction with the specified numerical ID." } ]
admin Output Fields Table 1020 on page 23779 lists the output fields for the show ovsdb commit failures command. Output fields are listed in the approximate order in which they appear. Table 1020: show ovsdb commit failures Output Fields Field Name Field Description Txn ID ID assigned to a transaction by the Juniper Ne...
Command introduced in Junos OS Release 14.1X53-D26.
[ "Understanding Dynamically Configured VXLANs in an OVSDB Environment" ]
show ovsdb controller
show ovsdb controller <address ip-address>
Display information and connection status for software-defined networking (SDN) controllers to which the Juniper Networks device is connected.
[ { "name": "none", "desc": "Display information about all SDN controllers to which the Juniper Networks device is connected." }, { "name": "address ip-address", "desc": "Display information about the SDN controller at the specified IP address." } ]
admin Output Fields Table 1021 on page 23782 lists the output fields for the show ovsdb controller command. Output fields are listed in the approximate order in which they appear. Table 1021: show ovsdb controller Output Fields Field Name Field Description Controller IP address IP address of the SDN controller to whic...
Command introduced in Junos OS Release 14.1R2.
[ "Setting Up the OVSDB Protocol on Juniper Networks Devices that Support Manual Configuration of", "VXLANs", "Setting Up OVSDB on Juniper Networks Devices That Support the Dynamic Configuration of", "VXLANs", "Understanding How to Set Up OVSDB Connections on a Juniper Networks Device" ]
show ovsdb interface
show ovsdb interface <interface-name>
Display information about Open vSwitch Database (OVSDB)-managed interfaces configured by using the interfaces interface-name statement in the [edit protocols ovsdb] hierarchy.
[ { "name": "none", "desc": "Display information about all OVSDB-managed interfaces." }, { "name": "interface-name", "desc": "Display information about the specified OVSDB-managed interface." } ]
admin Output Fields Table 1022 on page 23785 lists the output fields for the show ovsdb interface command. Output fields are listed in the approximate order in which they appear. Table 1022: show ovsdb interface Output Fields Field Name Field Description Interface Name of interface. VLAN ID ID of Virtual Extensible LAN...
Command introduced in Junos OS Release 14.1R2.
[ "Setting Up the OVSDB Protocol on Juniper Networks Devices that Support Manual Configuration of", "VXLANs", "Setting Up OVSDB on Juniper Networks Devices That Support the Dynamic Configuration of", "VXLANs" ]
show ovsdb logical-switch
show ovsdb logical-switch <logical-switch-name>
NOTE: In the Open vSwitch Database (OVSDB) schema for physical devices, the logical switch table stores information about the Layer 2 broadcast domain that you configured in a VMware NSX or Contrail environment. In the NSX environment, the Layer 2 broadcast domain is known as a logical switch, while in the Contrail env...
[ { "name": "none", "desc": "Display information about all logical switches that are present in the OVSDB schema for physical devices." }, { "name": "logical-switch-name", "desc": "Display information about the specified logical switch." } ]
admin Output Fields Table 1023 on page 23788 lists the output fields for the show ovsdb logical-switch command. Output fields are listed in the approximate order in which they appear. Table 1023: show ovsdb logical-switch Output Fields Field Name Field Description Logical Switch Name UUID that is automatically generate...
Command introduced in Junos OS Release 14.1R2.
[ "OVSDB Schema for Physical Devices", "Troubleshooting a Nonoperational Logical Switch and Corresponding Junos OS OVSDB-Managed", "VXLAN" ]
show ovsdb mac
show ovsdb mac <address mac-address> <local> <logical-switch logical-switch-uuid> <multicast> <remote> <unicast>
Display media access control (MAC) addresses, as well as information about the MAC addresses, learned by a Juniper Networks device that functions as a hardware virtual tunnel endpoint (VTEP). Using the Open vSwitch Database (OVSDB) management protocol, this hardware VTEP can learn about MAC addresses directly or from o...
[ { "name": "none", "desc": "Display all MAC addresses, which includes all local, remote, unicast, and multicast addresses associated with all logical switches." }, { "name": "address mac-address", "desc": "Display the specified MAC address." }, { "name": "count", "desc": "(All Juniper...
admin Output Fields Table 1024 on page 23792 lists the output fields for the show ovsdb mac command. Output fields are listed in the approximate order in which they appear. Table 1024: show ovsdb mac Output Fields Field Name Field Description Logical Switch Name Universally unique identifier (UUID) of the logical swit...
Command introduced in Junos OS Release 14.1R2.
[ "OVSDB Schema for Physical Devices" ]
show ovsdb statistics interface
show ovsdb statistics interface <interface-name>
Display statistics for Open vSwitch Database (OVSDB)-managed interfaces configured by using the interfaces interface-name statement in the [edit protocols ovsdb] hierarchy. When an interface is configured as OVSDB-managed, the collection of statistics for that interface begins, and the statistics displayed at any given...
[ { "name": "none", "desc": "Display statistics for all configured OVSDB-managed interfaces." }, { "name": "interface-name", "desc": "Display statistics for the specified interface." } ]
admin Output Fields Table 1025 on page 23796 lists the output fields for the show ovsdb statistics interface command. Output fields are listed in the approximate order in which they appear. Table 1025: show ovsdb statistics interface Output Fields Field Name Field Description Num of rx pkts Number of packets received b...
Command introduced in Junos OS Release 14.1R2.
[]
show ovsdb tunnels
show ovsdb tunnels <destination-address ip-address> <source-address ip-address>
Display the status of tunnels established between Juniper Networks devices that act as hardware virtual tunnel endpoints (VTEPs), and software VTEPs and service nodes that replicate Layer 2 broadcast, unknown unicast, and multicast (BUM) packets within a Virtual Extensible LAN (VXLAN) managed by the Open vSwitch Databa...
[ { "name": "none", "desc": "Display all tunnels." }, { "name": "destination-address ip-address(Optional)", "desc": "Display tunnels that have the specified destination address." }, { "name": "source-address ip-address(Optional)", "desc": "Display tunnels that have the specified source...
admin Output Fields Table 1026 on page 23800 lists the output fields for the show ovsdb tunnels command. Output fields are listed in the approximate order in which they appear. Table 1026: show ovsdb tunnels Output Fields Field Name Field Descriptions SRC IP Address IP address of the OVSDB-managed physical interface f...
Command introduced in Junos OS Release 14.1X53-D40.
[ "Understanding BFD in a VMware NSX Environment with OVSDB and VXLAN" ]
show ovsdb virtual-tunnel-end-point
show ovsdb virtual-tunnel-end-point address <ip-address> encapsulation <encapsulation-type>
Display information about the following entities that the Juniper Networks device has learned: • Other Juniper Networks devices that function as hardware virtual tunnel endpoints (VTEPs) • Software VTEPs • Service nodes • Top-of-rack service nodes (TSNs)
[ { "name": "none", "desc": "Display information about all VTEPs, service nodes, and TSNs that the Juniper Networks device has learned." }, { "name": "address ip-address", "desc": "Display information about the entity with the specified IP address." }, { "name": "encapsulation", "desc"...
admin Output Fields Table 1027 on page 23803 lists the output fields for the show ovsdb virtual-tunnel-end-point command. Output fields are listed in the approximate order in which they appear. Table 1027: show ovsdb virtual-tunnel-end-point Output Fields Field Name Field Description Encapsulation Encapsulation type o...
Command introduced in Junos OS Release 14.1R2.
[]
show passive-monitoring error
show passive-monitoring error (* | all | mo-fpc/pic/port)
(M40e, M160, and M320 Series routers and T Series routers only) Display passive monitoring error statistics.
[ { "name": "* | all | mo-fpc/pic/port", "desc": "Display error statistics for monitoring interfaces. Use a wildcard character, specify all interfaces, or provide a specific interface name." } ]
view Output Fields Table 1028 on page 23805 lists the output fields for the show passive-monitoring error command. Output fields are listed in the approximate order in which they appear. Table 1028: show passive-monitoring error Output Fields Field Name Field Description Passive monitoring interface Name of the passive...
Command introduced before Junos OS Release 7.4.
[]
show passive-monitoring flow
show passive-monitoring flow (* | all | mo-fpc/pic/port)
(M40e, M160, and M320 Series routers and T Series routers only) Display passive flow statistics.
[ { "name": "* | all | mo-fpc/pic/port", "desc": "Display passive flow statistics for monitoring interfaces. Use a wildcard character, specify all interfaces, or provide a specific interface name." } ]
view Output Fields Table 1029 on page 23808 lists the output fields for the show passive-monitoring flow command. Output fields are listed in the approximate order in which they appear. Table 1029: show passive-monitoring flow Output Fields Field Name Field Description Passive monitoring interface Name of the passive m...
Command introduced before Junos OS Release 7.4.
[]
show passive-monitoring memory
show passive-monitoring memory (* | all | mo-fpc/pic/port)
(M40e, M160, and M320 Series routers and T Series routers only) Display passive monitoring memory and flow record statistics
[ { "name": "* | all | mo-fpc/pic/port", "desc": "Display memory and flow record statistics for monitoring interfaces. Use a wildcard character, specify all interfaces, or provide a specific interface name." } ]
view Output Fields Table 1030 on page 23812 lists the output fields for the show passive-monitoring memory command. Output fields are listed in the approximate order in which they appear. Table 1030: show passive-monitoring memory Output Fields Field Name Field Description Passive monitoring interface Name of the pass...
Command introduced before Junos OS Release 7.4.
[]
show passive-monitoring status
show passive-monitoring status (*| all | mo-fpc/pic/port)
(M40e, M160, and M320 Series routers and T Series routers only) Display passive monitoring status.
[ { "name": "* | all | mo-fpc/pic/port", "desc": "Display status for monitoring interfaces. Use a wildcard character, specify all interfaces, or provide a specific interface name." } ]
view Output Fields Table 1031 on page 23814 lists the output fields for the show passive-monitoring status command. Output fields are listed in the approximate order in which they appear. Table 1031: show passive-monitoring status Output Fields Output Field Output Field Description Passive monitoring interface Name of...
Command introduced before Junos OS Release 7.4.
[]
show passive-monitoring usage
show passive-monitoring usage (* | all | mo-fpc/pic/port)
(M40e, M160, and M320 Series routers and T Series routers only) Display passive monitoring usage statistics.
[ { "name": "* | all | mo-fpc/pic/port", "desc": "Display usage statistics for monitoring interfaces. Use a wildcard character, specify all interfaces, or provide a specific interface name." } ]
view Output Fields Table 1032 on page 23816 lists the output fields for the show passive-monitoring usage command. Output fields are listed in the approximate order in which they appear. Table 1032: show passive-monitoring usage Output Fields Output Field Output Field Description Passive monitoring interface Name of th...
Command introduced before Junos OS Release 7.4.
[]
show path-computation-client active-pce
show path-computation-client active-pce <brief | detail>
Displays information about the current active Path Computation Element (PCE).
[ { "name": "none", "desc": "Display brief information about the current active PCE." }, { "name": "brief | detail", "desc": "(Optional) Display the specific level of output." } ]
view Output Fields Table 1033 on page 23819 describes the output fields for the show path-computation-client active-pce command. Output fields are listed in the approximate order in which they appear. Table 1033: show path-computation-client active-pce Output Fields Field Name Field Description Level of Output IP addr...
Command introduced in Junos OS Release 12.3.
[]
show path-computation-client lsp
show path-computation-client lsp <extensive (name lsp name)> <name> <p2mp>
Display the state of label-switched paths (LSPs) known to the Path Computation Client (PCC).
[ { "name": "none", "desc": "Display information about LSPs known to the PCC." }, { "name": "extensive", "desc": "(Optional) Display extensive level of output about each known LSP - point-to-point and point-to-multipoint LSPs." }, { "name": "name", "desc": "(Optional) Enter regular exp...
view Output Fields Table 1034 on page 23825 describes the output fields for the show path-computation-client lsp command. Output fields are listed in the approximate order in which they appear. Table 1034: show path-computation-client lsp Output Fields Field Name Field Description LSP Name Name of the LSP. Status LSP ...
Command introduced in Junos OS Release 17.2R1. extensive and p2mp options introduced in Junos OS Release 18.3R1 on MX Series routers. name option introduced in Junos OS Release 20.1R1 and Junos OS Evolved Release 20.1R1 on PTX10003-160C and PTX10008 routers.
[]
show path-computation-client statistics
show path-computation-client statistics <brief | detail> <all>
Display statistics about the Path Computation Element (PCE).
[ { "name": "none", "desc": "Display statistics about the primary PCE." }, { "name": "brief | detail", "desc": "(Optional) Display the specific level of output." }, { "name": "all", "desc": "(Optional) Display the statistics about all PCEs configured on the PCC." } ]
view Output Fields Table 1035 on page 23833 describes the output fields for the show path-computation-client statistics command. Output fields are listed in the approximate order in which they appear. Table 1035: show path-computation-client statistics Output Fields Field Name Field Description Level of Output IP addr...
Command introduced in Junos OS Release 12.3.
[]
show path-computation-client status
show path-computation-client status <extensive>
Display the status of the Path Computation Client (PCC).
[ { "name": "none", "desc": "Display the status of the PCC." }, { "name": "extensive", "desc": "(Optional) Display extensive information about the PCC including point-to-point and point-to-multipoint PCE-initiated LSPs. For point-to-multipoint PCE-initiated LSPs, the extensive output displays the ...
view Output Fields Table 1036 on page 23841 describes the output fields for the show path-computation-client status command. Output fields are listed in the approximate order in which they appear. Table 1036: show path-computation-client status Output Fields Field Name Field Description Session Name of the PCE with whi...
Command introduced in Junos OS Release 17.2R1. extensive option introduced in Junos OS Release 18.3R1 on MX Series routers.
[]
show performance-monitoring mpls lsp
show performance-monitoring mpls lsp <brief | detail | extensive> <name lsp name>
Display the following performance monitoring data: • Packet loss measurement • Packet throughput measurement • Two-way channel delay • Round-trip delay • Inter-packet delay variation (IPDV)
[ { "name": "none", "desc": "Display standard information performance monitoring data." }, { "name": "brief | detail |", "desc": "" }, { "name": "extensive", "desc": "(Optional) Display the specified level of output. NOTE: The extensive option displays the same information as the detai...
View Output Fields Table 1037 on page 23845 describes the output fields for the show performance-monitoring mpls lsp command. Output fields are listed in the approximate order in which they appear. Table 1037: show performance-monitoring mpls lsp Output Fields Field Name Display Data Field Description Level of Output ...
Command introduced in Junos OS Release 15.1.
[]
show pfe cfeb
show pfe cfeb
(M7i routers only) Display Packet Forwarding Engine Compact Forwarding Engine Board (CFEB) status and statistics information.
[]
admin Output Fields Table 1038 on page 23852 lists the output fields for the show pfe cfeb command. Output fields are listed in the approximate order in which they appear. Table 1038: show pfe cfeb Output Fields Field Name Field Description CFEB status Status of CFEB: • Slot—CFEB slot number. • State—Status of the CFE...
Command introduced before Junos OS Release 7.4.
[]
show pfe data
show pfe data <”usp flow config”> <”usp flow stats”>
Displays the Packet Forwarding Engine data. The Packet Forwarding Engine is the central processing element of the forwarding plane, systematically moving the packets in and out of the device. In Junos OS, the Packet Forwarding Engine has a locally stored forwarding table. The forwarding table is a synchronized copy of ...
[ { "name": "”usp flow config”", "desc": "Displays current flow configuration in logical system root-logical-system." }, { "name": "”usp flow stats”", "desc": "Displays current flow statistics." } ]
view Output Fields Table 1039 on page 23859 lists the output fields for the show pfe data command. Output fields are listed in the approximate order in which they appear. Table 1039: show pfe data Output Fields Field Name Field Description Flow main Parameters Information about flow main parameters: • allow-dns-reply—...
Command introduced in Junos OS Release 18.2R3-S3. Starting in Junos OS Release 18.2R3-S3, 19.1R3, 19.2R3, 19.3R3, 19.4R2, 20.1R2, you can now view the Packet Forwarding Engine data using the usp flow config and usp flow stats options for the show pfe data command.
[ "Junos OS Architecture Overview" ]
show pfe feb
show pfe feb
(M5 and M10 routers only) Display Packet Forwarding Engine Forwarding Engine Board (FEB) status and statistics information.
[]
admin Output Fields Table 1040 on page 23871 lists the output fields for the show pfe feb command. Output fields are listed in the approximate order in which they appear. Table 1040: show pfe feb Output Fields Field Name Field Description FEB status Status of FEB: • Slot—FEB slot number. • State—State of the FEB: • Off...
Command introduced before Junos OS Release 7.4.
[]
show pfe filter hw summary
show pfe filter hw summary
Display a summary of the access control list (ACL; also known as firewall filter) ternary content- addressable memory (TCAM) hardware utilization to show the allocated, used, and free TCAM entry space. Command supported on standalone QFX Series switches, QFX5100-only (pure QFX5100) Virtual Chassis Fabric (VCF), QFX5100...
[]
view Output Fields Table 1041 on page 23880 lists the output fields for the show pfe filter hw summary command. Output fields are listed in the approximate order in which they appear. Table 1041: show pfe filter hw summary Output Fields Field Name Field Description Group ACL ingress and egress filter groups: • iRACL gr...
Command introduced in Junos OS Release 14.1X53-D10. Command supported on EX Series in Junos OS Release 23.4R1.
[ "Planning the Number of Firewall Filters to Create" ]
show pfe fpc
show pfe fpc slot <detail | extensive> <all-members> <local> <member member-id>
Display Packet Forwarding Engine statistics for the specified Flexible PIC Concentrator (FPC). NOTE: Starting in Junos OS Evolved Releases 23.4R2 and 24.2R1, this command is disabled across all Junos OS Evolved platforms. Previously, the following error message was returned when executing the command: error: the statis...
[ { "name": "slot", "desc": "FPC slot number. Replace slot with a value from 0 through 2." }, { "name": "detail |", "desc": "" }, { "name": "extensive", "desc": "(Optional) Display the specified level of detail." }, { "name": "all-members", "desc": "(MX Series routers only)...
admin Output Fields Table 1042 on page 23885 lists the output fields for the show pfe fpc command. Output fields are listed in the approximate order in which they appear. Table 1042: show pfe fpc Output Fields Field Name Field Description FPC 1 status Status of FPC 1: • Slot—FPC slot number – 1. • State—State of FPC1:...
Command introduced before Junos OS Release 7.4.
[]
show pfe next-hop
show pfe next-hop <fpc slot> <interface interface-name> <lcc number>
Display Packet Forwarding Engine next-hop information.
[ { "name": "none", "desc": "Display all Packet Forwarding Engine next-hop information." }, { "name": "fpc slot", "desc": "(TX Matrix and TX Matrix Plus routers only) (Optional) Show the next hops for a Flexible PIC Concentrator (FPC) slot. On a TX Matrix router, if you specify the number of a T6...
admin Output Fields Table 1043 on page 23911 lists the output fields for the show pfe next hop command. Output fields are listed in the approximate order in which they appear. Table 1043: show pfe next-hop Output Fields Field Name Field Description ID The next-hop ID for the entry. Type The next-hop type for the entry....
Command introduced before Junos OS Release 7.4.
[ "Routing Matrix with TXP-T1600 Configuration", "Routing Matrix with TXP-T1600-3D Configuration", "Routing Matrix with TXP-T4000-3D Configuration", "Routing Matrix with a TXP-Mixed-LCC-3D Configuration" ]
show pfe route
show pfe route <fpc slot> <<inet6 | ip | iso> <prefix prefix> | <table <table-name> <index index> <prefix prefix>>> <lcc number> <mpls> <summary>
Display the routes in the Packet Forwarding Engine forwarding table. The Packet Forwarding Engine forwards packets between input and output interfaces. NOTE: The Routing Engine maintains a master copy of the forwarding table. It copies the forwarding table to the Packet Forwarding Engine, which is the part of the route...
[ { "name": "none", "desc": "Display all Packet Forwarding Engine forwarding table information." }, { "name": "clnp", "desc": "(Optional) Show International Standards Organization (ISO) connectionless-mode network protocol (CLNP) route table information." }, { "name": "dhcp", "desc": "...
admin Output Fields Table 1044 on page 23920 lists the output fields for the show pfe route command. Output fields are listed in the approximate order in which they appear. Table 1044: show pfe route Output Fields Field Name Field Description Destination Destination address for the entry. NH IP Addr Next-hop IP addres...
Command introduced before Junos OS Release 7.4. Command option hw introduced in Junos OS Release 14.1X53-D10 for the QFX Series. Command support introduced in Junos OS Evolved Release 22.4R1 for the PTX Series.
[ "Routing Matrix with TXP-T1600 Configuration", "Routing Matrix with TXP-T1600-3D Configuration", "Routing Matrix with TXP-T4000-3D Configuration", "Routing Matrix with a TXP-Mixed-LCC-3D Configuration" ]
show pfe sFlow egress-mcast-stats
show pfe sFlow egress-mcast-stats
Displays sFlow egress multicast sampling related statistics from the packet forwarding Engine. Dropped samples are the samples exceeding the maximum replication rate. When the router reaches 1990 replications of packets per second with the maximum being 2000 replications along with one packet for the multicast group wi...
[]
view Output Fields Table 1 lists the output fields for the show pfe sFlow egress-mcast-stats command. Table 1046: show pfe sFlow egress-mcast-stats Output Fields Field Name Field Description Slot FPC slot. Table 1046: show pfe sFlow egress-mcast-stats Output Fields (Continued) Field Name Field Description Rate per sec...
Command introduced in Junos OS Release 21.2R1.
[]
show pfe ssb
show pfe ssb
(M20 routers only) Display Packet Forwarding Engine System and Switch Board (SSB) status and statistics information.
[]
admin Output Fields Table 1047 on page 23933 lists the output fields for the show pfe ssb command. Output fields are listed in the approximate order in which they appear. Table 1047: show pfe ssb Output Fields Field Name Field Description Uptime (total) SSB uptime. Failures Number of failures . Pending Number of pendi...
Command introduced before Junos OS Release 7.4.
[]
show pfe statistics bridge
show pfe statistics bridge <fpc slot>
Display information about the number of packets discarded in the ingress pipeline of the Packet Forwarding Engine, packets discarded because of egress filtering or congestion filtering, number of control packets, and general counters for dropped packets. You can use this information to inform troubleshooting investigat...
[ { "name": "none", "desc": "Display bridge counter statistics for all Flexible PIC Concentrator (FPC) slots." }, { "name": "fpc slot", "desc": "(Optional) Display bridge counter statistics for a specific FPC slot." } ]
view Output Fields Table 1048 on page 23942 lists the output fields for the show pfe statistics bridge command. Output fields are listed in the approximate order in which they appear. Table 1048: show pfe statistics bridge Output Fields Field Name Field Description Ingress Counters Information about ingress counters: ...
Command introduced in Junos OS Release 12.1.
[ "Monitoring Switch Control Traffic" ]
show pfe terse
show pfe terse <all-members> <local> <member member-id>
Display Packet Forwarding Engine status information.
[ { "name": "none", "desc": "Display brief information about the Packet Forwarding Engine." }, { "name": "all-members", "desc": "(MX Series routers only) (Optional) Display Packet Forwarding Engine status information for all members in the Virtual Chassis configuration." }, { "name": "lcc ...
admin Sample Output show pfe terse (TX Matrix Router) user@host> show pfe terse Slot Type Slot State Flags Uptime 0 SFM Present Online 0x0bf 01:25:42 2 SFM Present Online 0x0bf 01:25:40 0 FPC Present Online 0x102 01:25:57 1 FPC Present Online 0x102 01:25:55 2 FPC Present Online 0x102 01:25...
Command introduced before Junos OS Release 7.4.
[]
show pfe version
show pfe version <brief | detail>
Display Packet Forwarding Engine version information.
[ { "name": "brief | detail", "desc": "Display the specified level of output." } ]
admin Sample Output show pfe version brief user@host> show pfe version brief PFED release 11.1D0 built by builder on 2010-11-11 05:16:11 UTC show pfe version detail user@host> show pfe version detail PFED release 11.1D0 built by builder on 2010-11-11 05:16:11 UTC device01.example.com:/volume/build/junos/rpd_feb11/1...
Command introduced before Junos OS Release 7.4.
[]
show pfe vxlan
show pfe vxlan <intf-usage | nh-usage | vport-usage>
You use the show pfe vxlan command options to show the utilization tables for Egress L3 Interface numbers, Egress L3 Next-hops, and source vports.
[ { "name": "intf-usage", "desc": "Show utilization of the Egress L3 Interface number table." }, { "name": "nh-usage", "desc": "Show utilization of the Egress L3 Next-hop table." }, { "name": "vport-usage", "desc": "Show utilization of the source vport table." } ]
view Output Fields Table 1049: show pfe vxlan intf-usage Output Fields Field Name Field Description Overlay bank size The maximum number of interfaces that can be configured for overlay networks. Reserved entries (Overlay) The number of reserved entries configured. Overlay intf num entries The number of local L3 interf...
Command introduced before Junos OS Release 22.2R3
[]
show pim bidirectional df-election interface
show pim bidirectional df-election interface <inet | inet6> <instance instance name> <interface-name> <logical-system (all | logical-system-name)>
For bidirectional PIM, display the default and the configured designated forwarder (DF) election parameters for each interface.
[ { "name": "none", "desc": "Display standard information about all interfaces." }, { "name": "inet | inet6", "desc": "(Optional) Display DF election parameters for IPv4 or IPv6 family addresses, respectively." }, { "name": "instance instance-name", "desc": "(Optional) Display DF elect...
view Output Fields Table 1052 on page 23957 describes the output fields for the show pim bidirectional df-election interface command. Output fields are listed in the approximate order in which they appear. Table 1052: show pim bidirectional df-election interface Output Fields Field Name Field Description Instance Name ...
Command introduced in Junos OS Release 12.1.
[]
show pim bidirectional df-election
show pim bidirectional df-election <brief | detail > <inet | inet6> <instance instance name> <logical-system (all | logical-system-name)> <rpa address>
For bidirectional PIM, display the designated forwarder (DF) election results for each interface grouped by the rendezvous point addresses (RPAs).
[ { "name": "none", "desc": "Display standard information about all interfaces." }, { "name": "brief | detail", "desc": "(Optional) Display the specified level of output." }, { "name": "inet | inet6", "desc": "(Optional) Display DF election results for IPv4 or IPv6 family addresses, re...
view Output Fields Table 1053 on page 23961 describes the output fields for the show pim bidirectional df-election command. Output fields are listed in the approximate order in which they appear. Table 1053: show pim bidirectional df-election Output Fields Field Name Field Description Level of Output Family IPv4 addres...
Command introduced in Junos OS Release 12.1.
[]
show pim bootstrap
show pim bootstrap <instance instance-name>
For sparse mode only, display information about Protocol Independent Multicast (PIM) bootstrap routers.
[ { "name": "none", "desc": "Display PIM bootstrap router information for all routing instances." }, { "name": "instance instance-name", "desc": "(Optional) Display information about bootstrap routers for a specific PIM-enabled routing instance." }, { "name": "logical-system (all | logical...
view Output Fields Table 1054 on page 23965 describes the output fields for the show pim bootstrap command. Output fields are listed in the approximate order in which they appear. Table 1054: show pim bootstrap Output Fields Field Name Field Description Instance Name of the routing instance. BSR Bootstrap router. Pri P...
Command introduced before Junos OS Release 7.4. instance option introduced in Junos OS Release 10.0 for EX Series switches.
[]
show pim interfaces
show pim interfaces <inet | inet6> <instance (instance-name | all)>
Display information about the interfaces on which Protocol Independent Multicast (PIM) is configured.
[ { "name": "none", "desc": "Display interface information for all family addresses for the main instance." }, { "name": "inet | inet6", "desc": "(Optional) Display interface information for IPv4 or IPv6 family addresses, respectively." }, { "name": "instance (instance-name |", "desc":...
view Output Fields Table 1055 on page 23968 describes the output fields for the show pim interfaces command. Output fields are listed in the approximate order in which they appear. Table 1055: show pim interfaces Output Fields Field Name Field Description Instance Name of the routing instance. Name Interface name. Stat...
Command introduced before Junos OS Release 7.4. inet6 and instance options introduced in Junos OS Release 10.0 for EX Series switches. Commmand introduced in Junos OS Release 11.3 for the QFX Series. Support for bidirectional PIM added in Junos OS Release 12.1. Support for the instance all option added in Junos OS Rele...
[]
show pim join
show pim join <brief | detail | extensive | summary> <dense | sparse> <exact> <inet | inet6> <instance (all | instance-name)> <range> <rp ip-address/prefix | source ip-address/prefix> <sg | star-g>
Display information about Protocol Independent Multicast (PIM) groups for all PIM modes. For bidirectional PIM, display information about PIM group ranges (*,G-range) for each active bidirectional RP group range, in addition to each of the joined (*,G) routes.
[ { "name": "none", "desc": "Display the standard information about PIM groups for all supported family addresses for all routing instances." }, { "name": "brief | detail | extensive |", "desc": "" }, { "name": "summary", "desc": "(Optional) Display the specified level of output." },...
view Output Fields Table 1056 on page 23974 describes the output fields for the show pim join command. Output fields are listed in the approximate order in which they appear. Table 1056: show pim join Output Fields Field Name Field Description Level of Output Instance Name of the routing instance. brief detail extensi...
Command introduced before Junos OS Release 7.4. summary option introduced in Junos OS Release 9.6. inet6 and instance options introduced in Junos OS Release 10.0 for EX Series switches. Support for bidirectional PIM added in Junos OS Release 12.1. Multiple new filter options introduced in Junos OS Release 13.2. downst...
[ "clear pim join", "Example: Configuring Multicast-Only Fast Reroute in a PIM Domain", "Example: Configuring Bidirectional PIM", "Example: Configuring PIM State Limits" ]
show pim mdt data-mdt-joins
show pim mdt data-mdt-joins <logical-system (all | logical-system-name)> instance instance-name
In a draft-rosen Layer 3 multicast virtual private network (MVPN) configured with service provider tunnels, display the advertisements of new multicast distribution tree (MDT) group addresses cached by the provider edge (PE) routers in the specified VPN routing and forwarding (VRF) instance that is configured to use th...
[ { "name": "instance", "desc": "" }, { "name": "instance-name", "desc": "Display data MDT join packets cached by PE routers in a specific PIM instance." }, { "name": "logical-system (all", "desc": "" }, { "name": "| logical-system-name)", "desc": "(Optional) Perform this o...
view Output Fields Table 1057 on page 23995 describes the output fields for the show pim mdt data-mdt-joins command. Output fields are listed in the approximate order in which they appear. Table 1057: show pim mdt data-mdt-joins Output Fields Field Name Field Description C-Group IPv4 group address in the address space ...
Command introduced in Junos OS Release 11.2.
[ "Understanding Data MDTs", "Example: Configuring Data MDTs and Provider Tunnels Operating in Source-Specific Multicast Mode", "Example: Configuring Data MDTs and Provider Tunnels Operating in Any-Source Multicast Mode" ]
show pim mdt data-mdt-limit
show pim mdt data-mdt-limit instance instance-name <logical-system (all | logical-system-name)>
Display the maximum number configured and the currently active data multicast distribution trees (MDTs) for a specific VPN routing and forwarding (VRF) instance.
[ { "name": "instance instance-name", "desc": "Display data MDT information for the specified VRF instance." }, { "name": "logical-system (all", "desc": "" }, { "name": "| logical-system-name)", "desc": "(Optional) Perform this operation on all logical systems or on a particular logica...
view Output Fields Table 1058 on page 23998 describes the output fields for the show pim mdt data-mdt-limit command. Output fields are listed in the approximate order in which they appear. Table 1058: show pim mdt data-mdt-limit Output Fields Field Name Field Description Maximum Data Tunnels Maximum number of data MDTs...
Command introduced in Junos OS Release 12.2.
[ "Understanding Data MDTs", "Example: Configuring Data MDTs and Provider Tunnels Operating in Source-Specific Multicast Mode", "Example: Configuring Data MDTs and Provider Tunnels Operating in Any-Source Multicast Mode" ]
show pim mdt
show pim mdt instance instance-name <brief | detail | extensive> data-mdt-joins data-mdt-limit inet inet6 <incoming | outgoing> <logical-system (all | logical-system-name)> <range>
Display information about Protocol Independent Multicast (PIM) default multicast distribution tree (MDT) and the data MDTs in a Layer 3 VPN environment for a routing instance.
[ { "name": "instance instance-name", "desc": "Display information about data-MDTs for a specific PIM-enabled routing instance." }, { "name": "brief | detail | extensive", "desc": "(Optional) Display the specified level of output." }, { "name": "data-mdt-joins", "desc": "Show received...
view Output Fields Table 1059 on page 24000 describes the output fields for the show pim mdt command. Output fields are listed in the approximate order in which they appear. Table 1059: show pim mdt Output Fields Field Name Field Description Level of Output Instance Name of the routing instance. All levels Tunnel direc...
Command introduced before Junos OS Release 7.4. Support for IPv6 added in Junos OS Release 17.3R1.
[]
show pim mvpn
show pim mvpn <logical-system (all | logical-system-name)>
Display information about multicast virtual private network (MVPN) instances.
[ { "name": "logical-system (all | logical-system-name)", "desc": "(Optional) Perform this operation on all logical systems or on a particular logical system." } ]
view Output Fields Table 1060 on page 24006 describes the output fields for the show pim mvpn command. Output fields are listed in the approximate order in which they appear. Table 1060: show pim mvpn Output Fields Field Name Field Description Level of Output Instance Name of the routing instance. All levels VPN-Group ...
Command introduced in Junos OS Release 9.4.
[]
show pim neighbors
show pim neighbors <brief | detail> <inet | inet6> <instance (instance-name | all)>
17.3R1 Starting in Junos OS release 17.3R1, uptime is not reset during ISSU.
[ { "name": "none", "desc": "(Same as brief) Display standard information about PIM neighbors for all supported family addresses for the main instance." }, { "name": "brief | detail", "desc": "(Optional) Display the specified level of output." }, { "name": "inet | inet6", "desc": "(Opt...
view Output Fields Table 1061 on page 24008 describes the output fields for the show pim neighbors command. Output fields are listed in the approximate order in which they appear. Table 1061: show pim neighbors Output Fields Field Name Field Description Level of Output Instance Name of the routing instance. All levels ...
Command introduced before Junos OS Release 7.4. inet6 and instance options introduced in Junos OS Release 10.0 for EX Series switches. Support for bidirectional PIM added in Junos OS Release 12.1. Support for the instance all option added in Junos OS Release 12.1. Support for RFC 5496 (via rpf-vector) added in Junos OS...
[]
show pim rps
show pim rps <brief | detail | extensive> <group-address> <inet | inet6> <instance (all | instance-name)>
Display information about Protocol Independent Multicast (PIM) rendezvous points (RPs).
[ { "name": "none", "desc": "Display standard information about PIM RPs for all groups and family addresses for all routing instances." }, { "name": "brief | detail | extensive", "desc": "(Optional) Display the specified level of output." }, { "name": "group-address", "desc": "(Optiona...
view Output Fields Table 1062 on page 24015 describes the output fields for the show pim rps command. Output fields are listed in the approximate order in which they appear. Table 1062: show pim rps Output Fields Field Name Field Description Level of Output Instance Name of the routing instance. All levels Table 1062:...
Command introduced before Junos OS Release 7.4. inet6 and instance options introduced in Junos OS Release 10.0 for EX Series switches. Support for bidirectional PIM added in Junos OS Release 12.1.
[ "Example: Configuring Bidirectional PIM" ]
show pim snooping interfaces
show pim snooping interfaces <brief | detail> <instance instance-name> <interface interface-name> <logical-system logical-system-name> <vlan-id vlan-identifier>
Display information about PIM snooping interfaces.
[ { "name": "none", "desc": "Display detailed information." }, { "name": "brief | detail", "desc": "(Optional) Display the specified level of output." }, { "name": "instance <instance-name>", "desc": "(Optional) Display PIM snooping interface information for the specified routing insta...
view Output Fields Table 1063 on page 24026 lists the output fields for the show pim snooping interface command. Output fields are listed in the approximate order in which they appear. Table 1063: show pim snooping interface Output Fields Field Name Field Description Level of Output Instance Routing instance for PIM sn...
Command introduced in Junos OS Release 12.3.
[ "PIM Snooping for VPLS" ]
show pim snooping join
show pim snooping join <brief | detail | extensive> <instance instance-name> <logical-system logical-system-name> <vlan-id vlan-id>
Display information about Protocol Independent Multicast (PIM) snooping joins.
[ { "name": "none", "desc": "Display detailed information." }, { "name": "brief | detail | extensive", "desc": "(Optional) Display the specified level of output." }, { "name": "instance instance-name", "desc": "(Optional) Display PIM snooping join information for the specified routing ...
view Output Fields Table 1064 on page 24030 lists the output fields for the show pim snooping join command. Output fields are listed in the approximate order in which they appear. Table 1064: show pim snooping join Output Fields Field Name Field Description Level of Output Instance Routing instance for PIM snooping. Al...
Command introduced in Junos OS Release 12.3.
[ "PIM Snooping for VPLS" ]
show pim snooping neighbors
show pim snooping neighbors <brief | detail> <instance instance-name> <interface interface-name> <logical-system logical-system-name> <vlan-id vlan-identifier>
Display information about Protocol Independent Multicast (PIM) snooping neighbors.
[ { "name": "none", "desc": "Display detailed information." }, { "name": "brief | detail", "desc": "(Optional) Display the specified level of output." }, { "name": "instance instance-name", "desc": "(Optional) Display PIM snooping neighbor information for the specified routing instance...
view Output Fields Table 1065 on page 24036 lists the output fields for the show pim snooping neighbors command. Output fields are listed in the approximate order in which they appear. Table 1065: show pim snooping neighbors Output Fields Field Name Field Description Level of Output Instance Routing instance for PIM sn...
Command introduced in Junos OS Release 12.3.
[ "Configuring Interface Priority for PIM Designated Router Selection", "Modifying the PIM Hello Interval", "PIM Snooping for VPLS", "show pim neighbors" ]
show pim snooping statistics
show pim snooping statistics <instance instance-name> <interface interface-name> <logical-system logical-system-name> <vlan-id vlan-id>
Display Protocol Independent Multicast (PIM) snooping statistics.
[ { "name": "none", "desc": "Display PIM statistics." }, { "name": "instance instance-name", "desc": "(Optional) Display statistics for a specific routing instance enabled by Protocol Independent Multicast (PIM) snooping." }, { "name": "interface interface-name", "desc": "(Optional) Di...
view Output Fields Table 1066 on page 24043 lists the output fields for the show pim snooping statistics command. Output fields are listed in the approximate order in which they appear. Table 1066: show pim snooping statistics Output Fields Field Name Field Description Level of Output Instance Routing instance for PIM ...
Command introduced in Junos OS Release 12.3.
[ "PIM Snooping for VPLS" ]
show pim source
show pim source <brief | detail> <inet | inet6> <instance instance-name> <source-prefix>
Display information about the Protocol Independent Multicast (PIM) source reverse path forwarding (RPF) state.
[ { "name": "none", "desc": "Display standard information about the PIM RPF state for all supported family addresses for all routing instances." }, { "name": "brief | detail", "desc": "(Optional) Display the specified level of output." }, { "name": "inet | inet6", "desc": "(Optional) D...
view Output Fields Table 1067 on page 24050 describes the output fields for the show pim source command. Output fields are listed in the approximate order in which they appear. Table 1067: show pim source Output Fields Field Name Field Description Instance Name of the routing instance. Source Address of the source or r...
Command introduced before Junos OS Release 7.4. inet6 and instance options introduced in Junos OS Release 10.0 for EX Series switches.
[]
show pim statistics
show pim statistics <inet |inet6)> <instance (all | instance-name)> <interface interface-name>
Display Protocol Independent Multicast (PIM) statistics.
[ { "name": "none", "desc": "Display PIM statistics." }, { "name": "inet | inet6", "desc": "(Optional) Display IPv4 or IPv6 PIM statistics, respectively." }, { "name": "instance (all | instance-name)", "desc": "(Optional) Display statistics for all routing instances or a specific routi...
view Output Fields Table 1068 on page 24054 describes the output fields for the show pim statistics command. Output fields are listed in the approximate order in which they appear. Table 1068: show pim statistics Output Fields Field Name Field Description Instance Name of the routing instance. This field only appears i...
Command introduced before Junos OS Release 7.4. inet6 and instance options introduced in Junos OS Release 10.0 for EX Series switches. Support for bidirectional PIM added in Junos OS Release 12.1.
[]
show poe controller (View)
show poe controller
Display the status of the Power over Ethernet (PoE) controller.
[ { "name": "none", "desc": "Display general parameters of the PoE software module controller." } ]
View Output Fields Table 1069 on page 24073 lists the output fields for the show poe controller command. Output fields are listed in the approximate order in which they appear. Table 1069: show poe controller Output Fields Field name Field Description Controller-index Identifies the controller. Maximum-power Specifies...
Command introduced in Junos OS Release 9.5.
[]
show poe controller
show poe controller
Display configuration and status of the PoE controllers.
[]
view Output Fields Table 1070 on page 24075 lists the output fields for the show poe controller command. Output fields are listed in the approximate order in which they appear. Table 1070: show poe controller Output Fields Field Name Field Description Controller index PoE controller number: • 0 for EX2200, EX3200, sta...
Command introduced in Junos OS Release 9.0. Command introduced in Junos OS Release 12.2 for ACX2000 routers. Statement introduced in Junos OS Release 17.2R1 for a Junos Fusion Provider Edge.
[ "request system firmware upgrade poe", "Verifying PoE Configuration and Status (CLI Procedure)", "Verifying PoE Configuration and Status for a Junos Fusion (CLI Procedure)", "Monitoring PoE Power Consumption (CLI Procedure)", "Upgrading the PoE Controller Software" ]
show poe interface
show poe interface <fpc-slot number> <interface-name>
Display the status of PoE interfaces.
[ { "name": "none", "desc": "Display status of all PoE interfaces on the switch or router." }, { "name": "fpc-slot number", "desc": "(Optional) (EX6200 or EX8200 switches only) Display the status of the PoE interfaces on" }, { "name": "interface-name", "desc": "(Optional) Display the s...
view Output Fields Table 1071 on page 24079 lists the output fields for the show poe interface command. Output fields are listed in the approximate order in which they appear. Table 1071: show poe interface Output Fields Field Name (All Interfaces Output) Field Name (Single Interface Output) Field Description Interface...
Command introduced in Junos OS Release 9.0. Command introduced in Junos OS Release 12.2 for ACX2000 routers.
[ "Enabling PoE on EX Series Switches (CLI Procedure)" ]
show poe notification-control
show poe notification-control
Display the state of the PoE notification-control option, which enables or disables PoE SNMP traps.
[]
view Output Fields Table 1072 on page 24089 lists the output fields for the show poe notification-control command. Output fields are listed in the approximate order in which they appear. Table 1072: show poe notification-control Output Fields Field Name Field Description FPC slot FPC slot number: • 0 for a standalone s...
Command introduced in Junos OS Release 9.0.
[ "Verifying PoE Configuration and Status (CLI Procedure)" ]
show poe telemetries
show poe telemetries <interface interface-name count number> <count number interface interface-name>
Display a history of power consumption on the specified interface. Telemetries must be enabled on the interface before you can display a history of power consumption.
[ { "name": "Interface interface-name", "desc": "Display telemetries for the specified PoE interface." }, { "name": "count number", "desc": "Display the specified number of telemetries records for the specified PoE interface." } ]
View Output Fields Table 1073 on page 24092 lists the output fields for the show poe telemetries interface command. Output fields are listed in the approximate order in which they appear. Table 1073: show poe telemetries interface Output Fields Field name Field Description S1 No Number of the record for the specified ...
Command modified in Junos OS Release 12.3X48-D10.
[]
show policer (EX)
show policer <policer-name>
Display statistics about configured policers.
[ { "name": "none", "desc": "Display the count of policed packets for all configured policers in the system." }, { "name": "policer-name", "desc": "(Optional) Display the count of policed packets for the specified policer." } ]
view Output Fields Table 1074 on page 24094 lists the output fields for the show policer command. Output fields are listed in the approximate order in which they appear. Table 1074: show policer Output Fields Field Name Field Description Level of Output Filter Name of filter that is configured with the filter statement...
Command introduced in Junos OS Release 9.0.
[ "Example: Configuring Firewall Filters for Port, VLAN, and Router Traffic on EX Series Switches", "Verifying That Firewall Filters Are Operational", "Verifying That Policers Are Operational", "Firewall Filters for EX Series Switches Overview", "Understanding the Use of Policers in Firewall Filters" ]
show policer
show policer <detail> <policer-name>
Display the number of policed packets for a given policer or an aggregate policer. An aggregate policer is an aggregate of different policers on the same logical interface.
[ { "name": "detail", "desc": "(Optional) Display additional statistics and counters. Requires the \"enhanced-policer\" on page 6690 statement to be enabled at the [edit chassis] hierarchy level. NOTE: show policer detail is not available for the following counters: three color policers, hierarchical policers...
view Output Fields Table 1075 on page 24097 lists the output fields for the show policer command. Output fields are listed in the approximate order in which they appear. Table 1075: show policer Output Fields Field Name Field Description Name Name of the policer. Policier detail also includes the following statistics:...
Command introduced before Junos OS Release 7.4. The command show policer detail was introduced in Junos OS Release 12.3.
[]
show policy conditions
show policy conditions <condition-name> <detail> <dynamic>
Display all the configured conditions as well as the routing tables with which the configuration manager is interacting. If the detail keyword is included, the output also displays dependent routes for each condition.
[ { "name": "none", "desc": "Display all configured conditions and associated routing tables." }, { "name": "condition-name", "desc": "(Optional) Display information about the specified condition only." }, { "name": "detail", "desc": "(Optional) Display the specified level of output." ...
view Output Fields Table 1076 on page 24102 lists the output fields for the show policy conditions command. Output fields are listed in the approximate order in which they appear. Table 1076: show policy conditions Output Fields Field Name Field Description Level of Output Condition Name of configured condition. All l...
Command introduced in Junos OS Release 9.0.
[]
show policy damping
show policy damping
Display information about BGP route flap damping parameters.
[ { "name": "none", "desc": "Display information about BGP route flap damping parameters." }, { "name": "logical-system (all | logical-system-name)", "desc": "(Optional) Perform this operation on all logical systems or on a particular logical system. Additional Information In the output from this ...
view Output Fields Table 1077 on page 24104 describes the output fields for the show policy damping command. Output fields are listed in the approximate order in which they appear. Table 1077: show policy damping Output Fields Field Name Field Description Halflife Decay half-life, in minutes. The value represents the p...
Command introduced before Junos OS Release 7.4.
[ "Routing Policies, Firewall Filters, and Traffic Policers User Guide", "clear bgp damping" ]