19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.5.1.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.5.1.4.1 Initial conditions | Test environment: normal; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
The test parameters are given in tables 8.6.5.1.4.1, 8.6.5.1.4.2 and 8.6.5.1.4.3. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2B and 3A shall be us... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.5.1.4.2 Procedure | 1) The RF parameters are set up according to T0 in Table 8.6.5.1.4.4 and 8.6.5.1.4.5.
2) The UE is switched on.
3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2.
4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compressed gaps)... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.5.1.5 Test requirements | Table 8.6.5.1.4.4: Cell Specific parameters for Correct reporting
of neighbours in AWGN propagation condition
Parameter
Unit
Cell 1
Cell 2
T0
T1
T2
T3
T4
T5
T0
T1
T2
T3
T4
T5
UTRA RF Channel Number
Channel 1
Channel 2
CPICH_Ec/Ior
dB
-9.2
-9.2
PCCPCH_Ec/Ior
dB
-11.2
-11.2
SCH_Ec/Ior
dB
-11.2
-11.2
PICH_Ec/Ior
dB
-14.2
... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6 E-UTRAN Measurement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1 Correct reporting of E-UTRAN FDD neighbour in fading propagation condition in CELL_DCH | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1.1 Definition and applicability | In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signallin... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1.2 Minimum requirement | When compressed mode gaps are used for E-UTRAN measurements, the UE shall be able to identify a new detectable E-UTRAN cell within
;
If the UE does not need compressed mode to perform E-UTRAN measurements, the UE shall be able to identify a new detectable E-UTRAN cell within ms.
Where:
TE-UTRAN: This is the minimum ti... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1.3 Test purpose | To verify that the UE meets the minimum requirement. The test is performed in fading propagation conditions. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1.4.1 Initial conditions | Test environment: normal; see clauses G.2.1 and G.2.2.
Frequencies to be tested: see table K.2 in Annex K.
The test consists of three successive time periods, with time duration T1, T2 and T3. The test parameters are given in tables 8.6.6.1.4.1, 8.6.6.1.4.2 and 8.6.6.1.4.3. In the measurement control information it is ... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1.4.2 Procedure | 1) The RF parameters for cell 1 are set up according to T0 in Table 8.6.6.1.5.1.
2) The UE is switched on.
3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2. The SS shall switch the power settings from T0 to T1 according to the parameters defined in 8.6.6.1.5.2 and 8.6.6.1.... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.1.5 Test requirements | If the UE needs compressed mode to perform E-UTRAN measurements:
- The UE shall send one Event 3C triggered measurement report for cell 2, with a measurement reporting delay less than 2.65 seconds from the beginning of time period T2.
- The UE shall send one Event 3B triggered measurement report for cell 2, with a meas... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2 Correct reporting of E-UTRAN TDD neighbour in fading propagation condition in CELL_DCH | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2.1 Definition and applicability | In the event triggered reporting period the measurement reporting delay is defined as the time between any events that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delay by other RRC signalling... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2.2 Minimum requirement | 1) In CELL_DCH state when a transmission gap pattern sequence is provided by the UTRAN the UE shall continuously measure previously detected E-UTRAN cells and search for new E-UTRAN cells.
- In order for the requirements in the following subsections to apply the UTRAN must provide a transmission gap pattern sequence wi... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2.3 Test purpose | To verify that the UE meets the minimum requirement. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2.4.1 Initial conditions | Test environment: normal; see clauses G.2.1 and G.2.2.
Frequencies to be tested: see table K.2 in Annex K.
The test parameters are given in table 8.6.6.2.2, 8.6.6.2.3 and 8.6.6.2.4 below. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 3B and 3C shall be used. ... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2.4.2 Procedure | 1) The RF parameters for cell 1 are set up according to T1 in Table 8.6.6.2.5.1 and 8.6.6.2.5.2.
2) The UE is switched on.
3) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.
4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Othe... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.6.2.5 Test requirements | For the test to pass, the total number of successful tests shall be more than 90% of the cases with a confidence level of 95 %.
NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 an... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7 Combined Inter-frequency and E-UTRAN measurements | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1 Correct reporting of E-UTRA FDD neighbours in fading propagation condition | Editor’s note: This Test case is incomplete for frequencies above 3GHz
• The Test system uncertainties applicable above 3GHz are undefined
• The Test Tolerances and Test Requirements applicable above 3GHz are undefined |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1.1 Definition and applicability | In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signallin... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1.2 Minimum requirement | The UE shall be able to identify a new detectable cell belonging to the monitored set within
ms
A cell shall be considered detectable when CPICH Ec/Io > -20 dB, SCH_Ec/Io > -17 dB for at least one channel tap and SCH_Ec/Ior is equally divided between primary synchronisation code and secondary synchronisation code. When... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1.3 Test purpose | To verify that the UE makes correct reporting of an event when doing inter frequency and E-UTRAN FDD measurements. The test will partly verify the requirements in TS 25.133 [2] clauses 8.1.2.3 and 8.1.2.6. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1.4.1 Initial conditions | Test environment: normal; see clauses G.2.1 and G.2.2.
Frequencies to be tested: see table K.2 in Annex K.
The test consists of two successive time periods, with time durations T1 and T2. The test parameters are given in tables 8.6.7.1.4.1, 8.6.7.1.4.2 and 8.6.7.1.4.3 below. In the measurement control information it is... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1.4.2 Procedure | 1) The RF parameters are set up according to T1 in Table 8.6.7.1.4.4 and 8.6.7.1.4.5.
2) The UE is switched on.
3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2. T1 starts.
4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compr... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.1.5 Test requirements | The UE shall send one Event 2B triggered measurement report for Cell2, with a measurement reporting delay less than 5.14 s from the beginning of time period T2.
The UE shall send one Event 3A triggered measurement report for Cell3, with a measurement reporting delay less than 8.23 s from the beginning of time period T2... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2 Correct reporting of E-UTRA TDD neighbours in Fading propagation condition | Editor’s note: This section is incomplete. The following aspects are either missing or not yet determined:
• The Test system uncertainties applicable above 3GHz are undefined
• The Test Tolerances and Test Requirements applicable above 3GHz are undefined |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2.1 Definition and applicability | In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signallin... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2.2 Minimum requirement | When transmission gaps are scheduled for FDD inter frequency measurements the UE shall be able to identify a new detectable cell belonging to the monitored set within
ms
The UE physical layer shall when transmission gaps are scheduled for FDD inter frequency measurements also be capable of reporting measurements to hig... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2.3 Test purpose | To verify that the UE makes correct reporting of an event when doing combined inter frequency and EUTRAN TDD measurements. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2.4.1 Initial conditions | Test environment: normal; see clauses G.2.1 and G.2.2.
Frequencies to be tested: see table K.2 in Annex K.
The test parameters are given in tables 8.6.7.2.4.1, 8.6.7.2.4.2 and 8.6.7.2.4.3. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2B and 3A shall be used.... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2.4.2 Procedure | 1) The RF parameters are set up according to T1 in Table 8.6.7.2.4.4 and 8.6.7.2.4.5.
2) The UE is switched on.
3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2 T1 starts.
4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compre... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.6.7.2.5 Test requirements | Table 8.6.7.2.4.4: Cell Specific parameters for correct reporting
of neighbours in fading propagation condition
Parameter
Unit
Cell 1
Cell 2
T1
T2
T1
T2
UTRA RF Channel Number
Channel 1
Channel 2
CPICH_Ec/Ior
dB
-10
-10
PCCPCH_Ec/Ior
dB
-12
-12
SCH_Ec/Ior
dB
-12
-12
PICH_Ec/Ior
dB
-15
-15
DPCH_Ec/Ior
dB
Note 1
N/A
OCNS... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1 CPICH RSCP | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1 Intra frequency measurements accuracy | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1 Absolute accuracy requirement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1.1 Definition and applicability | The absolute accuracy of CPICH RSCP is defined as the CPICH RSCP measured from one cell compared to the actual CPICH RSCP power from same cell.
The requirements and this test apply to all types of UTRA for the FDD UE. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1.2 Minimum Requirements | The accuracy requirements in table 8.7.1.1.1.1 are valid under the following conditions:
CPICH_RSCP1|dBm.according to Annex L.3.1 for a corresponding Band
Table 8.7.1.1.1.1: CPICH_RSCP Intra frequency absolute accuracy
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operating bands
Io [dBm/3,84MHz... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1.3 Test purpose | The purpose of this test is to verify that the CPICH RSCP absolute measurement accuracy is within the specified limits in clause 8.7.1.1.1.2. This measurement is for handover evaluation, DL open loop power control, UL open loop control and for the calculation of pathloss. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1.4.1 Initial conditions | Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
In this case all cells are on the same frequency. CPICH RSCP intra frequency absolute accuracy requirements are tested by using test parameters in table 8.7.1.1.1.2.
Table 8.7.1.1.1.... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1.4.2 Procedure | 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.1.1.1.4.
2) SS shall transmit MEASUREMENT CONTROL message.
3) UE shall transmit periodically MEASUREMENT REPORT messages.
4) SS shall check CPICH_RSCP value in MEAS... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.1.5 Test requirements | Table 8.7.1.1.1.3: CPICH_RSCP Intra frequency absolute accuracy, test requirement
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operating bands
Io [dBm/3,84MHz]
Minimum Io
Maximum Io
CPICH_RSCP
7.4
10.4
I, IV, VI, X, XI, XIX, XXI and XXXII
-94
-70
II, V and VII
-92
-70
XXV and XXVI
-90.5
(No... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2 Relative accuracy requirement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2.1 Definition and applicability | The relative accuracy of CPICH RSCP is defined as the CPICH RSCP measured from one cell compared to the CPICH RSCP measured from another cell on the same frequency.
The requirements and this test apply to all types of UTRA for the FDD UE. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2.2 Minimum Requirements | The accuracy requirements in table 8.7.1.1.2.1 are valid under the following conditions:
CPICH_RSCP1,2|dBm according to Annex B.3.2 for a corresponding Band.
Table 8.7.1.1.2.1: CPICH_RSCP Intra frequency relative accuracy
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operating bands
Io [dBm/3,84... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2.3 Test purpose | The purpose of this test is to verify that the CPICH RSCP relative measurement accuracy is within the specified limits in clause 8.7.1.1.2.2. This measurement is for handover evaluation, DL open loop power control, UL open loop control and for the calculation of pathloss. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2.4.1 Initial conditions | Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
In this case all cells are on the same frequency. CPICH RSCP intra frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.1.1.2. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2.4.2 Procedure | 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.1.1.2.3.
2) SS shall transmit MEASUREMENT CONTROL message.
3) UE shall transmit periodically MEASUREMENT REPORT messages.
4) SS shall check CPICH_RSCP value of Cell... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.1.2.5 Test requirements | Table 8.7.1.1.2.2: CPICH_RSCP Intra frequency relative accuracy, test requirements
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operating bands
Io [dBm/3,84 [MHz]
Minimum Io
Maximum Io
CPICH_RSCP
3.8
3.8
I, IV, VI, X, XI, XIX, XXI and XXXII
-94
-50
II, V and VII
-92
-50
XXV and XXVI
-90.5
(... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2 Inter frequency measurement accuracy | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1 Relative accuracy requirement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1.1 Definition and applicability | The relative accuracy of CPICH RSCP in inter frequency case is defined as the CPICH RSCP measured from one cell compared to the CPICH RSCP measured from another cell on a different frequency.
The requirements and this test apply to all types of UTRA for the FDD UE. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1.2 Minimum Requirements | The accuracy requirements in table 8.7.1.2.1.1 are valid under the following conditions:
CPICH_RSCP1|dBm according to Annex L.3.3 for a corresponding Band
| Channel 1_Io|dBm/3.84 MHz ‑Channel 2_Io|dBm/3.84 MHz | 20 dB.
Table 8.7.1.2.1.1: CPICH_RSCP Inter frequency relative accuracy
Parameter
Accuracy [dB]
Conditions
... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1.3 Test purpose | The purpose of this test is to verify that the CPICH RSCP relative measurement accuracy is within the specified limits in clause 8.7.1.2.1.2. This measurement is for handover evaluation, DL open loop power control, UL open loop control and for the calculation of pathloss. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1.4.1 Initial conditions | Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
In this case both cells are on different frequencies.
For UEs that require compressed mode, compressed mode is applied. The gap length is 7, detailed definition is in clause C.5, set... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1.4.2 Procedure | 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.1.2.1.4.
2) If compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Otherwise, go to step 4.
3) UE shall transmit PHYSICAL CHANN... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.1.2.1.5 Test requirements | Table 8.7.1.2.1.3: CPICH_RSCP Inter frequency relative accuracy, test requirements
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
CPICH_RSCP is on Band
Io [dBm/3,84 [MHz]
Minimum Io
Maximum Io
CPICH_RSCP
7.1
7.1
I, IV, VI, X, XI, XIX, XXI and XXXII
-94
-50
II, V and VII
-92
-50
XXV and XXVI
-... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2 CPICH Ec/Io | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1 Intra frequency measurements accuracy | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1 Absolute accuracy requirement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1.1 Definition and applicability | The absolute accuracy of CPICH Ec/Io is defined as the CPICH Ec/Io measured from one cell compared to the actual CPICH_Ec/Io power ratio from same cell.
The requirements and this test apply to all types of UTRA for the FDD UE. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1.2 Minimum Requirements | The accuracy requirements in table 8.7.2.1.1.1 are valid under the following conditions:
CPICH_RSCP1|dBm according to Annex L.3.4 for a corresponding Band
Table 8.7.2.1.1.1: CPICH_Ec/Io Intra frequency absolute accuracy, minimum requirements
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operatin... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1.3 Test purpose | The purpose of this test is to verify that the CPICH Ec/Io absolute measurement accuracy is within the specified limits in clause 8.7.2.1.1.2. This measurement is for Cell selection/re-selection and for handover evaluation. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1.4.1 Initial conditions | Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
In this case all cells are on the same frequency. CPICH Ec/Io intra frequency absolute accuracy requirements are tested by using the test parameters in table 8.7.2.1.1.2.
Table 8.7.2... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1.4.2 Procedure | 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.2.1.1.5.
2) SS shall transmit MEASUREMENT CONTROL message.
3) UE shall transmit periodically MEASUREMENT REPORT messages.
4) SS shall check CPICH_Ec/No value in ... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.1.5 Test requirements | The CPICH Ec/Io measurement accuracy shall meet the requirements in clause 8.7.2.1.1.2. The effect of assumed thermal noise and noise generated in the receiver (-99 dBm for Band I, IV, VI, X, XI, XIX, XXI and XXXII, -98dBm for Band IX, -97 dBm for Band II, V and VII, -96 dBm for Band III, VIII, XII, XIII, XIV, XX and ... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2 Relative accuracy requirement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2.1 Definition and applicability | The relative accuracy of CPICH Ec/Io is defined as the CPICH Ec/Io measured from one cell compared to the CPICH Ec/Io measured from another cell on the same frequency.
The requirements and this test apply to all types of UTRA for the FDD UE. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2.2 Minimum Requirements | The accuracy requirements in table 8.7.2.1.2.1 are valid under the following conditions:
CPICH_RSCP1,2|dBm according to Annex B.3.5 for a corresponding Band
Table 8.7.2.1.2.1: CPICH_Ec/Io Intra frequency relative accuracy
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operating bands
Io [dBm/3,84... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2.3 Test purpose | The purpose of this test is to verify that the CPICH Ec/Io relative measurement accuracy is within the specified limits in clause 8.7.2.1.2.2. This measurement is for Cell selection/re-selection and for handover evaluation. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2.4.1 Initial conditions | Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
In this case all cells are in the same frequency. CPICH Ec/Io intra frequency relative accuracy requirements are tested by using test parameters in table 8.7.2.1.1.2. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2.4.2 Procedure | 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.2.1.2.3.
2) SS shall transmit MEASUREMENT CONTROL message.
3) UE shall transmit periodically MEASUREMENT REPORT messages.
4) SS shall check CPICH_Ec/No value of ... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.1.2.5 Test requirements | Table 8.7.2.1.2.2: CPICH_Ec/Io Intra frequency relative accuracy
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operating bands
Io [dBm/3,84 [MHz]
Minimum Io
Maximum Io
The lower of the CPICH_Ec/Io from cell1 and cell2
2.3 for ‑14
CPICH Ec/Io 2.8 for ‑16
CPICH Ec/Io
<
-14 3.8 for ‑20
... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2 Inter frequency measurement accuracy | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.1 Absolute accuracy requirement | Void |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2 Relative accuracy requirement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2.1 Definition and applicability | The relative accuracy of CPICH Ec/Io in the inter frequency case is defined as the CPICH Ec/Io measured from one cell compared to the CPICH Ec/Io measured from another cell on a different frequency.
The relative accuracy is defined using the lower CPICH_Ec/Io of cell 1 and cell 2.
The requirements and this test apply t... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2.2 Minimum Requirements | The accuracy requirements in table 8.7.2.2.2.1 are valid under the following conditions:
CPICH_RSCP1|dBm according to Annex L.3.7 for a corresponding Band
| Channel 1_Io|dBm/3.84 MHz ‑Channel 2_Io|dBm/3.84 MHz | 20 dB.
Table 8.7.2.2.2.1: CPICH_Ec/Io Inter frequency relative accuracy, minimum requirements
Parameter
Ac... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2.3 Test purpose | The purpose of this test is to verify that the CPICH Ec/Io relative measurement accuracy is within the specified limits in clause 8.7.2.2.2.2. This measurement is for Cell selection/re-selection and for handover evaluation. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2.4.1 Initial conditions | Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
In this case both cells are on different frequencies.
For UEs that require compressed mode, compressed mode is applied. The gap length is 7, detailed definition is in clause C.5, set... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2.4.2 Procedure | 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.2.2.2.4.
2) If compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Otherwise, go to step 4.
3) UE shall transmit PHYSICAL CH... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.2.2.2.5 Test requirements | The effect of assumed thermal noise and noise generated in the receiver -99 dBm for Band I, IV, VI, X, XI, XIX, XXI and XXXII, -98dBm for Band IX, -97 dBm for Band II, V and VII, -96 dBm for Band IIII, VIII, XII, XIII, XIV, XX and XXII, -95.5 dBm for Band XXV and XXVI) shall be added into the required accuracy defined... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.3 UTRA Carrier RSSI | NOTE: This measurement is for Inter-frequency handover evaluation. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.3.1 Absolute measurement accuracy requirement | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.3.1.1 Definition and applicability | The absolute accuracy of UTRA Carrier RSSI is defined as the UTRA Carrier RSSI measured from one frequency compared to the actual UTRA Carrier RSSI power of that same frequency.
The requirements and this test apply to all types of UTRA for the FDD UE. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.3.1.2 Minimum Requirements | Table 8.7.3.1.1: UTRA Carrier RSSI Inter frequency absolute accuracy
Parameter
Accuracy [dB]
Conditions
Normal condition
Extreme condition
Operating bands
Io [dBm/3,84MHz]
Minimum Io
Maximum Io
UTRA Carrier RSSI
4
7
I, IV, VI, X, XI, XIX, XXI and XXXII
-94
-70
II, V and VII
-92
-70
XXV and XXVI
-90.5
(Note 1)
-70
I... |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.3.1.3 Test purpose | The purpose of this test is to verify that the UTRA Carrier RSSI measurement is within the specified limits. This measurement is for inter-frequency handover evaluation. |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.3.1.4 Method of test | |
19eaceb417a28bf040422bcad9ef7619 | 34.121-1 | 8.7.3.1.4.1 Initial conditions | Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2.
Frequencies to be tested: mid range; see clause G.2.4.
In this case both cells are on different frequencies.
For UEs that require compressed mode, compressed mode is applied. The gap length is 7, detailed definition is in clause C.5, Set... |