19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.5.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.5.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in tables 8.6.5.1.4.1, 8.6.5.1.4.2 and 8.6.5.1.4.3. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2B and 3A shall be us...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.5.1.4.2 Procedure
1) The RF parameters are set up according to T0 in Table 8.6.5.1.4.4 and 8.6.5.1.4.5. 2) The UE is switched on. 3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2. 4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compressed gaps)...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.5.1.5 Test requirements
Table 8.6.5.1.4.4: Cell Specific parameters for Correct reporting of neighbours in AWGN propagation condition Parameter Unit Cell 1 Cell 2 T0 T1 T2 T3 T4 T5 T0 T1 T2 T3 T4 T5 UTRA RF Channel Number Channel 1 Channel 2 CPICH_Ec/Ior dB -9.2 -9.2 PCCPCH_Ec/Ior dB -11.2 -11.2 SCH_Ec/Ior dB -11.2 -11.2 PICH_Ec/Ior dB -14.2 ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6 E-UTRAN Measurement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1 Correct reporting of E-UTRAN FDD neighbour in fading propagation condition in CELL_DCH
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1.1 Definition and applicability
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signallin...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1.2 Minimum requirement
When compressed mode gaps are used for E-UTRAN measurements, the UE shall be able to identify a new detectable E-UTRAN cell within ; If the UE does not need compressed mode to perform E-UTRAN measurements, the UE shall be able to identify a new detectable E-UTRAN cell within ms. Where: TE-UTRAN: This is the minimum ti...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1.3 Test purpose
To verify that the UE meets the minimum requirement. The test is performed in fading propagation conditions.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table K.2 in Annex K. The test consists of three successive time periods, with time duration T1, T2 and T3. The test parameters are given in tables 8.6.6.1.4.1, 8.6.6.1.4.2 and 8.6.6.1.4.3. In the measurement control information it is ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1.4.2 Procedure
1) The RF parameters for cell 1 are set up according to T0 in Table 8.6.6.1.5.1. 2) The UE is switched on. 3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2. The SS shall switch the power settings from T0 to T1 according to the parameters defined in 8.6.6.1.5.2 and 8.6.6.1....
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.1.5 Test requirements
If the UE needs compressed mode to perform E-UTRAN measurements: - The UE shall send one Event 3C triggered measurement report for cell 2, with a measurement reporting delay less than 2.65 seconds from the beginning of time period T2. - The UE shall send one Event 3B triggered measurement report for cell 2, with a meas...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2 Correct reporting of E-UTRAN TDD neighbour in fading propagation condition in CELL_DCH
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2.1 Definition and applicability
In the event triggered reporting period the measurement reporting delay is defined as the time between any events that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delay by other RRC signalling...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2.2 Minimum requirement
1) In CELL_DCH state when a transmission gap pattern sequence is provided by the UTRAN the UE shall continuously measure previously detected E-UTRAN cells and search for new E-UTRAN cells. - In order for the requirements in the following subsections to apply the UTRAN must provide a transmission gap pattern sequence wi...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2.3 Test purpose
To verify that the UE meets the minimum requirement.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table K.2 in Annex K. The test parameters are given in table 8.6.6.2.2, 8.6.6.2.3 and 8.6.6.2.4 below. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 3B and 3C shall be used. ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2.4.2 Procedure
1) The RF parameters for cell 1 are set up according to T1 in Table 8.6.6.2.5.1 and 8.6.6.2.5.2. 2) The UE is switched on. 3) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. 4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Othe...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.6.2.5 Test requirements
For the test to pass, the total number of successful tests shall be more than 90% of the cases with a confidence level of 95 %. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 an...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7 Combined Inter-frequency and E-UTRAN measurements
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1 Correct reporting of E-UTRA FDD neighbours in fading propagation condition
Editor’s note: This Test case is incomplete for frequencies above 3GHz • The Test system uncertainties applicable above 3GHz are undefined • The Test Tolerances and Test Requirements applicable above 3GHz are undefined
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1.1 Definition and applicability
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signallin...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1.2 Minimum requirement
The UE shall be able to identify a new detectable cell belonging to the monitored set within ms A cell shall be considered detectable when CPICH Ec/Io > -20 dB, SCH_Ec/Io > -17 dB for at least one channel tap and SCH_Ec/Ior is equally divided between primary synchronisation code and secondary synchronisation code. When...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1.3 Test purpose
To verify that the UE makes correct reporting of an event when doing inter frequency and E-UTRAN FDD measurements. The test will partly verify the requirements in TS 25.133 [2] clauses 8.1.2.3 and 8.1.2.6.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table K.2 in Annex K. The test consists of two successive time periods, with time durations T1 and T2. The test parameters are given in tables 8.6.7.1.4.1, 8.6.7.1.4.2 and 8.6.7.1.4.3 below. In the measurement control information it is...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1.4.2 Procedure
1) The RF parameters are set up according to T1 in Table 8.6.7.1.4.4 and 8.6.7.1.4.5. 2) The UE is switched on. 3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2. T1 starts. 4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compr...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.1.5 Test requirements
The UE shall send one Event 2B triggered measurement report for Cell2, with a measurement reporting delay less than 5.14 s from the beginning of time period T2. The UE shall send one Event 3A triggered measurement report for Cell3, with a measurement reporting delay less than 8.23 s from the beginning of time period T2...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2 Correct reporting of E-UTRA TDD neighbours in Fading propagation condition
Editor’s note: This section is incomplete. The following aspects are either missing or not yet determined: • The Test system uncertainties applicable above 3GHz are undefined • The Test Tolerances and Test Requirements applicable above 3GHz are undefined
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2.1 Definition and applicability
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit the measurement report over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signallin...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2.2 Minimum requirement
When transmission gaps are scheduled for FDD inter frequency measurements the UE shall be able to identify a new detectable cell belonging to the monitored set within ms The UE physical layer shall when transmission gaps are scheduled for FDD inter frequency measurements also be capable of reporting measurements to hig...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2.3 Test purpose
To verify that the UE makes correct reporting of an event when doing combined inter frequency and EUTRAN TDD measurements.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table K.2 in Annex K. The test parameters are given in tables 8.6.7.2.4.1, 8.6.7.2.4.2 and 8.6.7.2.4.3. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2B and 3A shall be used....
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2.4.2 Procedure
1) The RF parameters are set up according to T1 in Table 8.6.7.2.4.4 and 8.6.7.2.4.5. 2) The UE is switched on. 3) A call is set up according to the test procedure specified in TS 34.108 [3] sub clause 7.3.2 T1 starts. 4) If Compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compre...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.6.7.2.5 Test requirements
Table 8.6.7.2.4.4: Cell Specific parameters for correct reporting of neighbours in fading propagation condition Parameter Unit Cell 1 Cell 2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 CPICH_Ec/Ior dB -10 -10 PCCPCH_Ec/Ior dB -12 -12 SCH_Ec/Ior dB -12 -12 PICH_Ec/Ior dB -15 -15 DPCH_Ec/Ior dB Note 1 N/A OCNS...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1 CPICH RSCP
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1 Intra frequency measurements accuracy
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1 Absolute accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1.1 Definition and applicability
The absolute accuracy of CPICH RSCP is defined as the CPICH RSCP measured from one cell compared to the actual CPICH RSCP power from same cell. The requirements and this test apply to all types of UTRA for the FDD UE.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1.2 Minimum Requirements
The accuracy requirements in table 8.7.1.1.1.1 are valid under the following conditions: CPICH_RSCP1|dBm.according to Annex L.3.1 for a corresponding Band Table 8.7.1.1.1.1: CPICH_RSCP Intra frequency absolute accuracy Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operating bands Io [dBm/3,84MHz...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1.3 Test purpose
The purpose of this test is to verify that the CPICH RSCP absolute measurement accuracy is within the specified limits in clause 8.7.1.1.1.2. This measurement is for handover evaluation, DL open loop power control, UL open loop control and for the calculation of pathloss.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. CPICH RSCP intra frequency absolute accuracy requirements are tested by using test parameters in table 8.7.1.1.1.2. Table 8.7.1.1.1....
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.1.1.1.4. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check CPICH_RSCP value in MEAS...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.1.5 Test requirements
Table 8.7.1.1.1.3: CPICH_RSCP Intra frequency absolute accuracy, test requirement Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operating bands Io [dBm/3,84MHz] Minimum Io Maximum Io CPICH_RSCP  7.4  10.4 I, IV, VI, X, XI, XIX, XXI and XXXII -94 -70 II, V and VII -92 -70 XXV and XXVI -90.5 (No...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2 Relative accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2.1 Definition and applicability
The relative accuracy of CPICH RSCP is defined as the CPICH RSCP measured from one cell compared to the CPICH RSCP measured from another cell on the same frequency. The requirements and this test apply to all types of UTRA for the FDD UE.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2.2 Minimum Requirements
The accuracy requirements in table 8.7.1.1.2.1 are valid under the following conditions: CPICH_RSCP1,2|dBm according to Annex B.3.2 for a corresponding Band. Table 8.7.1.1.2.1: CPICH_RSCP Intra frequency relative accuracy Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operating bands Io [dBm/3,84...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2.3 Test purpose
The purpose of this test is to verify that the CPICH RSCP relative measurement accuracy is within the specified limits in clause 8.7.1.1.2.2. This measurement is for handover evaluation, DL open loop power control, UL open loop control and for the calculation of pathloss.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. CPICH RSCP intra frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.1.1.2.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.1.1.2.3. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check CPICH_RSCP value of Cell...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.1.2.5 Test requirements
Table 8.7.1.1.2.2: CPICH_RSCP Intra frequency relative accuracy, test requirements Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operating bands Io [dBm/3,84 [MHz] Minimum Io Maximum Io CPICH_RSCP  3.8  3.8 I, IV, VI, X, XI, XIX, XXI and XXXII -94 -50 II, V and VII -92 -50 XXV and XXVI -90.5 (...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2 Inter frequency measurement accuracy
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1 Relative accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1.1 Definition and applicability
The relative accuracy of CPICH RSCP in inter frequency case is defined as the CPICH RSCP measured from one cell compared to the CPICH RSCP measured from another cell on a different frequency. The requirements and this test apply to all types of UTRA for the FDD UE.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1.2 Minimum Requirements
The accuracy requirements in table 8.7.1.2.1.1 are valid under the following conditions: CPICH_RSCP1|dBm according to Annex L.3.3 for a corresponding Band | Channel 1_Io|dBm/3.84 MHz ‑Channel 2_Io|dBm/3.84 MHz |  20 dB. Table 8.7.1.2.1.1: CPICH_RSCP Inter frequency relative accuracy Parameter Accuracy [dB] Conditions ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1.3 Test purpose
The purpose of this test is to verify that the CPICH RSCP relative measurement accuracy is within the specified limits in clause 8.7.1.2.1.2. This measurement is for handover evaluation, DL open loop power control, UL open loop control and for the calculation of pathloss.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. For UEs that require compressed mode, compressed mode is applied. The gap length is 7, detailed definition is in clause C.5, set...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.1.2.1.4. 2) If compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Otherwise, go to step 4. 3) UE shall transmit PHYSICAL CHANN...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.1.2.1.5 Test requirements
Table 8.7.1.2.1.3: CPICH_RSCP Inter frequency relative accuracy, test requirements Parameter Accuracy [dB] Conditions Normal condition Extreme condition CPICH_RSCP is on Band Io [dBm/3,84 [MHz] Minimum Io Maximum Io CPICH_RSCP  7.1  7.1 I, IV, VI, X, XI, XIX, XXI and XXXII -94 -50 II, V and VII -92 -50 XXV and XXVI -...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2 CPICH Ec/Io
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1 Intra frequency measurements accuracy
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1 Absolute accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1.1 Definition and applicability
The absolute accuracy of CPICH Ec/Io is defined as the CPICH Ec/Io measured from one cell compared to the actual CPICH_Ec/Io power ratio from same cell. The requirements and this test apply to all types of UTRA for the FDD UE.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1.2 Minimum Requirements
The accuracy requirements in table 8.7.2.1.1.1 are valid under the following conditions: CPICH_RSCP1|dBm according to Annex L.3.4 for a corresponding Band Table 8.7.2.1.1.1: CPICH_Ec/Io Intra frequency absolute accuracy, minimum requirements Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operatin...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1.3 Test purpose
The purpose of this test is to verify that the CPICH Ec/Io absolute measurement accuracy is within the specified limits in clause 8.7.2.1.1.2. This measurement is for Cell selection/re-selection and for handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. CPICH Ec/Io intra frequency absolute accuracy requirements are tested by using the test parameters in table 8.7.2.1.1.2. Table 8.7.2...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.2.1.1.5. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check CPICH_Ec/No value in ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.1.5 Test requirements
The CPICH Ec/Io measurement accuracy shall meet the requirements in clause 8.7.2.1.1.2. The effect of assumed thermal noise and noise generated in the receiver (-99 dBm for Band I, IV, VI, X, XI, XIX, XXI and XXXII, -98dBm for Band IX, -97 dBm for Band II, V and VII, -96 dBm for Band III, VIII, XII, XIII, XIV, XX and ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2 Relative accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2.1 Definition and applicability
The relative accuracy of CPICH Ec/Io is defined as the CPICH Ec/Io measured from one cell compared to the CPICH Ec/Io measured from another cell on the same frequency. The requirements and this test apply to all types of UTRA for the FDD UE.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2.2 Minimum Requirements
The accuracy requirements in table 8.7.2.1.2.1 are valid under the following conditions: CPICH_RSCP1,2|dBm according to Annex B.3.5 for a corresponding Band Table 8.7.2.1.2.1: CPICH_Ec/Io Intra frequency relative accuracy Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operating bands Io [dBm/3,84...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2.3 Test purpose
The purpose of this test is to verify that the CPICH Ec/Io relative measurement accuracy is within the specified limits in clause 8.7.2.1.2.2. This measurement is for Cell selection/re-selection and for handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are in the same frequency. CPICH Ec/Io intra frequency relative accuracy requirements are tested by using test parameters in table 8.7.2.1.1.2.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.2.1.2.3. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check CPICH_Ec/No value of ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.1.2.5 Test requirements
Table 8.7.2.1.2.2: CPICH_Ec/Io Intra frequency relative accuracy Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operating bands Io [dBm/3,84 [MHz] Minimum Io Maximum Io The lower of the CPICH_Ec/Io from cell1 and cell2  2.3 for ‑14  CPICH Ec/Io  2.8 for ‑16  CPICH Ec/Io < -14  3.8 for ‑20  ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2 Inter frequency measurement accuracy
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.1 Absolute accuracy requirement
Void
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2 Relative accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2.1 Definition and applicability
The relative accuracy of CPICH Ec/Io in the inter frequency case is defined as the CPICH Ec/Io measured from one cell compared to the CPICH Ec/Io measured from another cell on a different frequency. The relative accuracy is defined using the lower CPICH_Ec/Io of cell 1 and cell 2. The requirements and this test apply t...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2.2 Minimum Requirements
The accuracy requirements in table 8.7.2.2.2.1 are valid under the following conditions: CPICH_RSCP1|dBm according to Annex L.3.7 for a corresponding Band | Channel 1_Io|dBm/3.84 MHz ‑Channel 2_Io|dBm/3.84 MHz |  20 dB. Table 8.7.2.2.2.1: CPICH_Ec/Io Inter frequency relative accuracy, minimum requirements Parameter Ac...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2.3 Test purpose
The purpose of this test is to verify that the CPICH Ec/Io relative measurement accuracy is within the specified limits in clause 8.7.2.2.2.2. This measurement is for Cell selection/re-selection and for handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. For UEs that require compressed mode, compressed mode is applied. The gap length is 7, detailed definition is in clause C.5, set...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.2.2.2.4. 2) If compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Otherwise, go to step 4. 3) UE shall transmit PHYSICAL CH...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.2.2.2.5 Test requirements
The effect of assumed thermal noise and noise generated in the receiver -99 dBm for Band I, IV, VI, X, XI, XIX, XXI and XXXII, -98dBm for Band IX, -97 dBm for Band II, V and VII, -96 dBm for Band IIII, VIII, XII, XIII, XIV, XX and XXII, -95.5 dBm for Band XXV and XXVI) shall be added into the required accuracy defined...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3 UTRA Carrier RSSI
NOTE: This measurement is for Inter-frequency handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.1 Absolute measurement accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.1.1 Definition and applicability
The absolute accuracy of UTRA Carrier RSSI is defined as the UTRA Carrier RSSI measured from one frequency compared to the actual UTRA Carrier RSSI power of that same frequency. The requirements and this test apply to all types of UTRA for the FDD UE.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.1.2 Minimum Requirements
Table 8.7.3.1.1: UTRA Carrier RSSI Inter frequency absolute accuracy Parameter Accuracy [dB] Conditions Normal condition Extreme condition Operating bands Io [dBm/3,84MHz] Minimum Io Maximum Io UTRA Carrier RSSI  4  7 I, IV, VI, X, XI, XIX, XXI and XXXII -94 -70 II, V and VII -92 -70 XXV and XXVI -90.5 (Note 1) -70 I...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.1.3 Test purpose
The purpose of this test is to verify that the UTRA Carrier RSSI measurement is within the specified limits. This measurement is for inter-frequency handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. For UEs that require compressed mode, compressed mode is applied. The gap length is 7, detailed definition is in clause C.5, Set...