34.121-1
8.7.3.1.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.3.1.2. 2) If compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Otherwise, go to step 4. 3) UE shall transmit PHYSICAL CHAN...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.1.5 Test requirements
The UTRA Carrier RSSI absolute measurement accuracy shall meet the requirements in clause 8.7.3.1.2. The effect of assumed thermal noise and noise generated in the receiver (-99 dBm for Band I, IV, VI, X, XI, XIX and XXI, -98dBm for Band IX, -97 dBm for Band II, V and VII, -96 dBm for Band III, VIII, XII, XIII, XIV, X...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2 Relative measurement accuracy requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2.1 Definition and applicability
The relative accuracy requirement is defined as the UTRA Carrier RSSI measured from one frequency compared to the UTRA Carrier RSSI measured from another frequency. The requirements and this test apply for Release 6 and later releases to all types of UTRA for the FDD UE.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2.2 Minimum Requirements
The accuracy requirements in table 8.7.3.2.1 are valid under the following condition: |Channel 1_Io|dBm/3.84 MHz ‑ |Channel 2_Io|dBm/3.84 MHz < 20 dB. Table 8.7.3.2.1: UTRA Carrier RSSI Inter frequency relative accuracy Parameter Accuracy [dB] Conditions Normal condition Extreme condition UTRA Carrier RSSI is on Band I...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2.3 Test purpose
The purpose of this test is to verify that the UTRA Carrier RSSI measurement is within the specified limits. This measurement is for inter-frequency handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on different frequencies and compressed mode is applied. The gap length is 7, detailed definition is in clause C.5, Set 1 of table C.5.2 except for TGRRC a...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.3.2.3. 2) SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. 3) UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message. 4) SS shall transmit M...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.3.2.5 Test requirements
The UTRA Carrier RSSI relative measurement accuracy shall meet the requirements in clause 8.7.3.2.2. The effect of assumed thermal noise and noise generated in the receiver (-99 dBm for Band I, IV, VI, X, XI, XIX, XXI and XXXII, -98dBm for Band IX, -97 dBm for Band II, V and VII, -96 dBm for Band III, VIII, XII, XIII, ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4 SFN-CFN observed time difference
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1 Intra frequency measurement requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1.1 Definition and applicability
The intra frequency SFN-CFN observed time difference is defined as the SFN-CFN observed time difference from the active cell to a neighbour cell that is in the same frequency. This measurement is specified in clause 5.1.8 of TS 25.215 [22]. The reference point for the SFN-CFN observed time difference shall be the anten...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1.2 Minimum requirements
The accuracy requirement in table 8.7.4.1.1 is valid under the following conditions: CPICH_RSCP1,2|dBm according to Annex L.3.8 for a corresponding Band is low enough to ensure successful SFN decoding. Table 8.7.4.1.1: SFN-CFN observed time difference intra frequency accuracy Parameter Accuracy [chip] Conditions Operat...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1.3 Test Purpose
The purpose of this test is to verify that the SFN-CFN observed time difference measurement accuracy is within the specified limits in the clause 8.7.4.1.2. This measurement is for handover timing purposes to identify active cell and neighbour cell time difference.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. During the test the timing difference between Cell 1 and 2 can be set to value from 0…9830399 chips. In this case all cells are in the same frequency. Table 8.7.4.1.2 defines the lim...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.4.1.4. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT message. 4) SS shall check "OFF" and "Tm" values in...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.1.5 Test requirements
Table 8.7.4.1.3: SFN-CFN observed time difference intra frequency accuracy Parameter Accuracy [chip] Conditions Operating bands Io [dBm/3,84 [MHz] Minimum Io Maximum Io SFN-CFN observed time difference  1.5 I, IV, VI, X, XI, XIX, XXI and XXXII -94 -50 II, V and VII -92 -50 XXV and XXVI -90.5 (Note 1) -50 III, VIII, XI...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2 Inter frequency measurement requirement
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2.1 Definition and applicability
The inter frequency SFN-CFN observed time difference is defined as the SFN-CFN time difference from the active cell to a neighbour cell that is in a different frequency. This measurement is specified in clause 5.1.8 of TS 25.215 [22]. The reference point for the SFN-CFN observed time difference shall be the antenna con...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2.2 Minimum requirements
The accuracy requirement in table 8.7.4.2.1 is valid under the following conditions: CPICH_RSCP1|dBm according to Annex L.3.9 for a corresponding Band. | Channel 1_Io|dBm/3.84 MHz ‑Channel 2_Io|dBm/3.84 MHz |  20 dB. Table 8.7.4.2.1: SFN-CFN observed time difference inter frequency accuracy Parameter Accuracy [chip] C...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2.3 Test purpose
The purpose of this test is to verify that the SFN-CFN observed time difference measurement accuracy is within the specified limits in the clause 8.7.4.2.2. This measurement is for handover timing purposes to identify active cell and neighbour cell time difference.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. During the test the timing difference between Cell 1 and 2 can be set to value from 0…9830399 chips. In this test case both cells are on different frequencies. For UEs that require c...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.4.2.4. 2) If compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message. Otherwise go to step 4. 3) UE shall transmit PHYSICAL CHANN...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.4.2.5 Test requirements
Table 8.7.4.2.3: SFN-CFN observed time difference inter frequency accuracy Parameter Accuracy [chip] Conditions SFN-CFN observed time difference is on Band Io [dBm/3,84 [MHz] Minimum Io Maximum Io SFN-CFN observed time difference  1.5 I, IV, VI, X, XI, XIX, XXI and XXXII -94 -50 II, V and VII -92 -50 XXV and XXVI -90....
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5 SFN-SFN observed time difference
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.1 SFN-SFN observed time difference type 1
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.1.1 Definition and applicability
This measurement is specified in clause 5.1.9 of TS 25.215 [22]. The reference point for the SFN-SFN observed time difference type 1 shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA for the FDD UE. 8.7.5.1.2 Minimum requirements The accuracy requirement in table 8.7.5...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.1.3 Test purpose
The purpose of this test is to verify that the measurement accuracy of SFN-SFN observed time difference type 1 is within the limit specified in clause 8.7.5.1.2. This measurement is for identifying time difference between two cells.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. During the test the timing difference between Cell 1 and 2 can be set to value from 0…9830399 chips. 1) Connect SS to the UE antenna connector as shown in figure A.14. In this case all cells are in the same fre...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.1.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.5. The RF parameters for Test 1 are set up according to table 8.7.5.1.4. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check "SFN-SFN observed ti...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.1.5 Test requirements
Table 8.7.5.1.3: SFN-SFN observed time difference type 1 measurement accuracy Parameter Accuracy [chip] Conditions SFN-SFN observed time difference type 1 is on Band Io [dBm/3,84 [MHz] Minimum Io Maximum Io SFN-SFN observed time difference type1  1.5 I, IV, VI, X, XI, XIX, XXI and XXXII -94 -50 II, V and VII -92 -50 X...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.2 SFN-SFN observed time difference type 2 without IPDL period active
NOTE: This test case is not complete and there are currently no plans to complete it.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.2.1 Definition and applicability
This measurement is specified in clause 5.1.9 of TS 25.215 [22]. The reference point for the SFN-SFN observed time difference type 2 shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA for the FDD UE supporting this measurement.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.2.2 Minimum requirements
The accuracy requirement in table 8.7.5.2.1 is valid under the following conditions: CPICH_RSCP1,2|dBm according to Annex L.3.11 for a corresponding Band Table 8.7.5.2.1: SFN-SFN observed time difference type 2 measurement accuracy Parameter Accuracy [chip] Conditions Operating bands Io [dBm/3,84 [MHz] Minimum Io Maxim...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.2.3 Test purpose and Environment
The purpose of this test is to verify that the SFN-SFN observed time difference type 2 measurement accuracy without IPDL period active is within the limits specified in clause 8.7.5.2.2. During the test the time difference between Cell 1 and 2 can be set to value from ‑1279.75 to 1280 chips. In this case all cells are ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.3 SFN-SFN observed time difference type 2 with IPDL period active
Note: This test case is not complete and there are currently no plans to complete it.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.3.1 Definition and applicability
This measurement is specified in clause 5.1.9 of TS 25.215 [22]. The reference point for the SFN-SFN observed time difference type 2 shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA for the FDD UE supporting IPDL measurements.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.3.2 Minimum requirements
The accuracy requirement in table 8.7.5.3.1 is valid under the following conditions: CPICH_RSCP1,2|dBm according to Annex B.3.11 for a corresponding Band Additionally the accuracy requirement in table 8.7.5.3.1 is also valid for neighbour cells for which the following conditions apply to during idle periods provided id...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.5.3.3 Test purpose and Environment
The purpose of this test is to verify that the SFN-SFN observed time difference type 2 measurement accuracy without IPDL period active is within the limits specified in clause 8.7.5.2.2. During the test the time difference between Cell 1 and 2 shall be set according to the assistance data defined in table 8.7.5.3.3. In...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6 UE Rx-Tx time difference
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1 UE Rx-Tx time difference type 1 (Release 5 and earlier)
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1.1 Definition and applicability
The UE Rx-Tx time difference is defined as the time difference between the UE uplink DPCCH/DPDCH frame transmission and the first detected path (in time) of the downlink DPCH frame from the measured radio link. The reference point of the UE Rx-Tx time difference shall be the antenna connector of the UE. This measuremen...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1.2 Minimum requirements
Table 8.7.6.1.1: UE Rx-Tx time difference type 1 measurement accuracy Parameter Accuracy [chip] Conditions Operating bands Io [dBm/3,84 [MHz] Minimum Io Maximum Io UE RX-TX time difference  1.5 I, IV, VI, X, XI, XIX and XXI -94 -50 II, V and VII -92 -50 XXV and XXVI -90.5 (Note 1) -50 III, VIII, XII, XIII, XIV, XX and...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1.3 Test purpose
The purpose of this test is to verify that the measurement accuracy of Rx-Tx time difference is within the limit specified in clause 8.7.6.1.2. This measurement is used for call setup purposes to compensate propagation delay of DL and UL.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. 1) Connect SS to the UE antenna connector as shown in figure A.1 Table 8.7.6.1.2: UE Rx-Tx time difference type 1 intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 1 Cell 1 UTRA RF...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters are set up according to table 8.7.6.1.4 for Test 1. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT message. 4) SS shall check "UE Rx-Tx time differenc...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.1.5 Test requirements
Table 8.7.6.1.3 UE Rx-Tx time difference type 1 measurement accuracy Parameter Accuracy [chip] Conditions Operating bands Io [dBm/3,84 [MHz] Minimum Io Maximum Io UE RX-TX time difference  2.0 I, IV, VI, X, XI, XIX and XXI -94 -50 II, V and VII -92 -50 XXV and XXVI -90.5 (Note 1) -50 III, VIII, XII, XIII, XIV, XX and ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.2 UE Rx-Tx time difference type 2
NOTE: This test case is not complete and there are currently no plans to complete it.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.2.1 Definition and applicability
The UE Rx-Tx time difference is defined as the time difference between the UE uplink DPCCH/DPDCH frame transmission and the first detected path (in time) of the downlink DPCH frame from the measured radio link. The reference point of the UE Rx-Tx time difference shall be the antenna connector of the UE. This measuremen...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.2.2 Minimum requirements
Table 8.7.6.2.1: UE Rx-Tx time difference type 2 measurement accuracy Parameter Accuracy [chip] Conditions Operating bands Io [dBm/3,84 [MHz] Minimum Io Maximum Io UE RX-TX time difference  1.0 I, IV, VI, X, XI, XIX and XXI -94 -50 II, V and VII -92 -50 XXV and XXVI -90.5 (Note 1) -50 III, VIII, XII, XIII, XIV, XX and...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.6.2.3 Test purpose
The purpose of this test is to verify that the measurement accuracy of Rx-Tx time difference type 2 is within the limit specified in clause 8.7.6.2.2. The connection is started using cell 1, then cell 2 is added to the active set so that cell 1 is the timing reference. During the test the downlink DPCH time difference ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.7 Observed time difference to GSM cell (R99 and Rel-4 only)
Void
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8 P-CCPCH RSCP
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1 Absolute measurement accuracy
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.1 Definition and applicability
The absolute accuracy of P-CCPCH RSCP is defined as the P-CCPCH RSCP measured in an UTRA TDD cell on one frequency compared to the actual P-CCPCH RSCP power of that cell on the same frequency. The requirements and this test apply only to UE supporting both UTRA FDD and UTRA TDD for Release 99 and Release 4 only.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.2 Minimum Requirements
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.2.1 3.84Mcps TDD option
The accuracy requirement in table 8.7.8.1.1 is valid under the following conditions: P-CCPCH_RSCP  -102 dBm, Table 8.7.8.1.1: P-CCPCH RSCP inter frequency absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal conditions Extreme conditions Io [dBm/3.84 MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.2.2 1.28Mcps TDD option
The accuracy requirement in table 9.31A is valid under the following conditions: P-CCPCH RSCP  -102 dBm P-CCPCH Ec/Io > -8 dB Table 8.7.8.1.1A: P-CCPCH RSCP inter frequency absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal conditions Extreme conditions Io [dBm/1.28 MHz] P-CCPCH_RSCP dBm  6  9 -94...-7...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.3 Test purpose
The purpose of this test is to verify that the P-CCPCH RSCP absolute measurement accuracy is within the specified limits.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.4.1 Initial conditions
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.4.1.1 3.84Mcps TDD option
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 is a UTRA FDD cell and cell 2 is a 3.84Mcps TDD cell. The second Beacon timeslot shall be provided for cell 2 in timeslot...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.4.1.2 1.28Mcps TDD option
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 is a UTRA FDD cell and cell 2 is a 1.28McpsTDD cell. The second Beacon timeslot shall be provided for cell 2 in timeslot ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.4.2 Procedure
1) SS shall transmit the PHYSICAL CHANNEL RECONFIGURATION message. 2) UE shall transmit the PHYSICAL CHANNEL RECONFIGURATION COMPLETE message. 3) SS shall transmit the MEASUREMENT CONTROL message. 4) UE shall transmit periodically MEASUREMENT REPORT messages. 5) SS shall check P-CCPCH RSCP values of Cell 2 in the MEASU...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.8.1.5 Test requirements
The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.8.1.2. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requi...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9 UE Transmission Power Headroom
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9.1 Definition and applicability
The accuracy requirements for the UE transmission power headroom depends on the total power transmitted by the UE as defined in the functionality in section 9.2.5.3.2 of TS 25.321 [13], section 9.1.13.4 of TS 25.133 [2] and section 5.1.14 of TS 25.215 [22]. The requirements and this test apply to Release 6 and later r...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9.2 Minimum Requirements
The UE transmission power headroom (UPH) is defined in section 5.1.14 of TS 25.215 [22] as the ratio of the maximum UE transmission power and the corresponding DPCCH code power, and shall be calculated as following: where: Pmax,tx = min {Maximum allowed UL TX Power, Pmax} is the UE maximum transmission power; Maximum a...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9.3 Test purpose
The purpose of this test case is to verify that the UE transmission power headroom measurement report accuracy is within the specified limits defined in section 9.1.13.4 of 25.133 [2] shown in table 8.7.9.1.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. 1) Connect the SS (node B emulator) to the UE antenna connector as shown in figure A.1. 2) The beta factors for E-DPCCH & HS-DPCCH, Reference E-TFCI index, and E-DCH configurations a...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9.4.2 Test procedure
1) The Scheduling Information configuration for the E-DCH indicates to the UE that it shall periodically report Scheduling Information, which contains UPH measurement every E-DCH TTI. During the test the system simulator shall not send any scheduling grant to the UE, and therefore the UE will not send any payload data ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.9.5 Test requirements
The UE transmission power headroom measurement report accuracy recorded in steps 6, 9 and 10 above shall meet the requirements in table 8.7.9.5. The rate of correct measurements observed during repeated tests shall be at least 90%. To pass the test, the UE transmission power headroom accuracy for each power level in th...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10 E-UTRAN FDD RSRP absolute accuracy (CELL_DCH)
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10.1 Definition and applicability
The absolute accuracy of RSRP is defined as the RSRP measured from a cell that has different carrier frequency from the serving cell. The E-UTRAN FDD RSRP absolute accuracy measurement is used for handover between UTRAN FDD and E-UTRAN FDD. The requirements and this test apply to the combined UTRAN FDD and E-UTRAN FDD ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10.2 Minimum Requirements
The accuracy requirements for E-UTRA RSRP measurements in CELL_DCH state shall be the same as the inter-frequency RSRP accuracy requirements in3GPP TS36.133[34], as follows: Cell specific reference signals are transmitted either from one, two or four antenna ports. Conditions defined in TS 36.101 [37] clause 7.3 for re...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10.3 Test purpose
The purpose of this test is to verify that the E-UTRAN FDD RSRP measurement accuracy in CELL_DCH state, for UE that needs compressed mode to perform E-UTRAN FDD measurements, is within the specified limits. This measurement is for UTRAN FDD to E-UTRAN FDD handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table K.2 in Annex K. In the test in Cell_DCH state compressed mode with purpose "E-UTRAN FDD RSRP Measurement" is applied to measure on E-UTRAN FDD. The compressed mode pattern repeats every 80 ms and uses ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10.4.2 Test Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.10.5.2 and table 8.7.10.5.3. 2) If compressed mode is required,SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compressed gaps). Otherwise, Go to Ste...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.10.5 Test requirements
Table 8.7.10.5.2 and table 8.7.10.5.3 defines the primary level settings including test tolerances for all tests. For the test to pass, the ratio of successful reported values according to table 8.7.10.5.4 in each test shall be more than 90% with a confidence level of 95%. Table 8.7.10.5.1: Void Table 8.7.10.5.2: UTRAN...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11 E-UTRAN TDD RSRP absolute accuracy (CELL_DCH)
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11.1 Definition and applicability
The absolute accuracy of RSRP is defined as the RSRP measured from a cell that has different carrier frequency from the serving cell. The E-UTRAN TDD RSRP absolute accuracy measurement is used for handover between UTRAN FDD and E-UTRAN TDD. The requirements and this test apply to the combined UTRAN FDD and E-UTRAN TDD ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11.2 Minimum Requirements
The accuracy requirements for E-UTRA RSRP measurements in CELL_DCH state shall be the same as the inter-frequency RSRP accuracy requirements in3GPP TS36.133[34], as follows: - Cell specific reference signals are transmitted either from one, two or four antenna ports. - Conditions defined in 36.101 Section 7.3 for refer...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11.3 Test purpose
The purpose of this test is to verify that the E-UTRAN TDD RSRP measurement accuracy in CELL_DCH state, for UE that needs compressed mode to perform E-UTRAN TDD measurements, is within the specified limits. This measurement is for UTRAN FDD to E-UTRAN TDD handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table K.2 in Annex K. In the test in Cell_DCH state compressed mode with purpose "E-UTRAN TDD RSRP Measurement" is applied to measure on E-UTRAN TDD. The compressed mode pattern repeats every 80 ms and uses ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11.4.2 Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.11.5.2 and table 8.7.11. 5.3. 2) If compressed mode is required, SS shall transmit PHYSICAL CHANNEL RECONFIGURATION message (compressed gaps). Otherwise, Go to S...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.11.5 Test requirements
Table 8.7.11.5.2 and table 8.7.11.5.3 define the primary level settings including test tolerances for all tests. For the test to pass, the ratio of successful reported values according to table 8.7.10.5.4 in each test shall be more than 90% with a confidence level of 95%. Table 8.7.11.5.1: Void Table 8.7.11.5.2: UTRAN ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.12 E-UTRAN FDD RSRQ absolute accuracy (CELL_DCH)
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.12.1 Definition and applicability
The absolute accuracy of RSRQ is defined as the RSRQ measured from a cell that has different carrier frequency from the serving cell. The E-UTRAN FDD RSRQ absolute accuracy measurement is used for handover between UTRAN FDD and E-UTRAN FDD. The requirements and this test apply to the combined UTRAN FDD and E-UTRAN FDD ...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.12.2 Minimum Requirements
The accuracy requirements for E-UTRA RSRQ measurements in CELL_DCH state shall be the same as the inter-frequency RSRQ accuracy requirements in3GPP TS36.133[34], as follows: - Cell specific reference signals are transmitted either from one, two or four antenna ports. - Conditions defined in TS 36.101 [37] clause 7.3 fo...
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.12.3 Test purpose
The purpose of this test is to verify that the E-UTRAN FDD RSRQ measurement accuracy in CELL_DCH state, for UE that needs compressed mode to perform E-UTRAN FDD measurements, is within the specified limits. This measurement is for UTRAN FDD to E-UTRAN FDD handover evaluation.
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.12.4 Method of test
19eaceb417a28bf040422bcad9ef7619
34.121-1
8.7.12.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table K.2 in Annex K In the test in Cell_DCH state compressed mode with purpose "E-UTRAN FDD RSRQ Measurement" is applied to measure on E-UTRAN FDD. The compressed mode pattern repeats every 80 ms and uses a...