hash
stringlengths
32
32
doc_id
stringlengths
5
12
section
stringlengths
5
1.47k
content
stringlengths
0
6.67M
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.1.5 Test Requirement
After step 5 the UE shall start to transmit 2 MEASUREMENT REPORT messages at 64 seconds interval. The measurement quantity "CPICH RSCP" of cell 2 shall be reported in these messages. After step 7 the UE shall not transmit any MEASUREMENT REPORT messages within 64 seconds after SS has transmitted the MEASUREMENT CONTROL...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.2 Measurement Control and Report: Inter-frequency measurement for transition from idle mode to CELL_DCH state (FDD)
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.2.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.2.2 Conformance requirement
Upon transition from idle mode to CELL_DCH state, the UE shall: 1> stop monitoring the list of cells assigned in the IE "inter-frequency cell info list" in System Information Block type 12 (or System Information Block type 11). Upon reception of a MEASUREMENT CONTROL message the UE shall: 1> read the IE "Measurement co...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.2.3 Test Purpose
1. To confirm that the UE stops monitoring the list of cells assigned in the IE "inter-frequency cell info" in System Information Block type 11 messages, after it enters CELL_DCH state from idle mode. 2. To confirm that the UE, which requires compressed mode, starts to perform inter-frequency measurement and related re...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.2.4 Method of test
Initial Condition System Simulator: 2 cells – Cell 1 and cell 4 are active. UE: "Registered idle mode on CS" (state 2) or "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE st...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.2.5 Test Requirement
After step 5 the UE shall not transmit any MEASUREMENT REPORT messages pertaining to the measurement of CPICH RSCP of cell 4. If UE requires compressed mode operation, after step 5, UE shall activate compressed mode operations at the time indicated by IE "TGCFN" and then transmit PHYSICAL CHANNEL RECONFIGURATION COMPLE...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.3 Measurement Control and Report: Intra-frequency measurement for transition from idle mode to CELL_FACH state (FDD)
8.4.1.3.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.3.2 Conformance requirement
Upon transition from idle mode to CELL_FACH state, the UE shall: 1> begin or continue monitoring cells listed in the IE "intra-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11). In CELL_FACH state, the UE shall: 1> include a measurement report in the IE "Measur...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.3.3 Test Purpose
1. To confirm that the UE begins or continues to monitor cells listed in IE "intra-frequency cell info list" of System Information Block type 11 or 12 messages after it has entered CELL_FACH state from idle mode. 2. To confirm that the UE applies the reporting criteria stated in "intra-frequency measurement reporting c...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.3.4 Method of test
Initial Condition System Simulator: 2 cells. Cell 1 and cell 2 are active. SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents). UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108. If the UE supports both CS and PS domains, the initial UE state shall be "Registered i...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.3.5 Test Requirement
After step 5 the UE shall not transmit any MEASUREMENT REPORT messages on the uplink DCCH. After step 6 the UE shall initiate cell update procedure by transmitting CELL UPDATE message on CCCH. In this message, IE "cell update cause" shall be set to "periodic cell update". It shall include IE "measured results on RACH",...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.4 Measurement Control and Report: Inter-frequency measurement for transition from idle mode to CELL_FACH state (FDD)
8.4.1.4.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.4.2 Conformance requirement
Upon transition from idle mode to CELL_FACH state, the UE shall: 1> begin or continue monitoring cells listed in the IE "inter-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11); Reference 3GPP TS 25.331, clause 8.4.1.9.2
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.4.3 Test Purpose
1. To confirm that the UE begins to monitor the list of cells assigned in the IE "inter-frequency cell info list" in System Information Block type 11 or 12 messages, after it enters CELL_FACH state from idle mode. However, it shall not transmit any MEASUREMENT REPORT messages to report measured results for inter-freque...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.4.4 Method of test
Initial Condition System Simulator: 2 cells – Cell 1 and cell 4 are active. UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/P...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.4.5 Test Requirement
After step 5 the UE shall not transmit any MEASUREMENT REPORT messages pertaining to any measurement quantities for cell 4. After step 7 the UE shall reselect to cell 4 and transmit a CELL UPDATE message on the uplink CCCH of cell 4. After step 9, the UE shall transmit a UTRAN MOBILITY INFORMATION CONFIRM message on up...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.5 Measurement Control and Report: Intra-frequency measurement for transition from CELL_DCH to CELL_FACH state (FDD)
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.5.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.5.2 Conformance requirement
Upon transition from CELL_DCH to CELL_FACH/CELL_PCH/URA_PCH state, the UE shall: 1> stop intra-frequency type measurement reporting; 1> if the transition is due to a reconfiguration message which included the IE "Primary CPICH info" (for FDD) or "Primary CCPCH info" (for TDD), and the UE selects a cell other than that ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.5.3 Test Purpose
1. To confirm that the UE stops performing intra-frequency measurement reporting specified in a MEASUREMENT CONTROL message, when it moves from CELL_DCH state to CELL_FACH state. 2. To confirm that the UE reads the System Information Block type 11 or 12 messages when it enters CELL_FACH state from CELL_DCH state, and s...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.5.4 Method of test
Initial Condition System Simulator: 3 cells – Cell 1 and cell 2 are active, while cell 3 is switched off.. SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents). UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108. Related ICS/IXIT statements - PS Supported yes/no Specific Mess...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.5.5 Test Requirement
After step 5, the UE shall start to transmit MEASUREMENT REPORT messages at 16 seconds interval. The first message may contain the IE "Cell measured results" to report cell 2's CPICH RSCP value, subsequent messages shall contain this IE. After step 8, the UE shall not send any MEASUREMENT REPORT messages containing rep...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.6 Measurement Control and Report: Inter-frequency measurement for transition from CELL_DCH to CELL_FACH state (FDD)
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.6.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.6.2 Conformance requirement
Upon transition from CELL_DCH to CELL_FACH/ CELL_PCH/URA_PCH state, the UE shall: 1> stop the inter-frequency type measurement reporting assigned in a MEASUREMENT CONTROL message; 1> begin monitoring cells listed in the IE "inter-frequency cell info list" received in System Information Block type 12 (or System Informat...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.6.3 Test Purpose
1. To confirm that UE ceases inter-frequency type measurement reporting assigned in MEASUREMENT CONTROL message when moving from CELL_DCH state to CELL_FACH. 2. To confirm that the UE begins to monitor the cells listed in "inter-frequency cell info" received in System Information Block type 11 or 12 messages, following...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.6.4 Method of test
Initial Condition System Simulator: 2 cells – Cell 1 and cell 2 are active. UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108. Related ICS/IXIT statements - Compressed mode required yes/no Specific Message contents System Information Block type 4 Use the same message type found in clau...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.6.5 Test Requirement
If UE requires compressed mode, after step 6, the UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC. After step 8 the UE shall transmit MEASUREMENT REPORT message to report cell 4's RSCP value in the IE "inter-frequency cell measured results". After step 10, the UE shal...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.7 Measurement Control and Report: Intra-frequency measurement for transition from CELL_FACH to CELL_DCH state (FDD)
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.7.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.7.2 Conformance requirement
Upon transition from CELL_FACH to CELL_DCH state: 1> if intra-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY: 2> if the cell in which the UE transited from CELL_FACH state is included in the active set for the CELL_DCH state, the UE shall: 3> resume the measurement r...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.7.3 Test Purpose
- To confirm that UE retrieves stored measurement control information for intra-frequency measurement type with "measurement validity" assigned to "CELL_DCH", after it enters CELL_DCH state from CELL_FACH state. - To confirm that the UE continues to monitor the neighbouring cells listed "intra-frequency cell info" IE i...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.7.4 Method of test
Initial Condition System Simulator: 3 cells – Cell 1, cell 2 and cell 3 are active. SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents). UE: PS-DCCH+DTCH_FACH (state 6-11). Test Procedure Table 8.4.1.7-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execut...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.7.5 Test Requirement
After step 3 the UE shall report cell 2's CPICH RSCP value by transmitting MEASUREMENT REPORT messages. After step 5 the UE shall transmit two MEASUREMENT REPORT messages which contain measured results of cell 3's CPICH RSCP value only, one for measurement identity 10 and one for measurement identity 11. After step 9 a...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.8 Measurement Control and Report: Inter-frequency measurement for transition from CELL_FACH to CELL_DCH state (FDD)
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.8.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.8.2 Conformance requirement
Upon transition from CELL_FACH to CELL_DCH state, the UE shall: 1> if inter-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY: 2> if the cell in which the UE transited from CELL_FACH state is included in the active set for the CELL_DCH state, the UE shall: 3> resume the...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.8.3 Test Purpose
1. To confirm that the UE resumes inter-frequency measurements and reporting stored for which the measurement control information has IE "measurement validity" assigned to the value "CELL_DCH", after it re-enters CELL_DCH state from CELL_FACH state. 2. To confirm that the UE resumes inter-frequency measurement and repo...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.8.4 Method of test
Initial Condition System Simulator: 2 cells – Cell 1, cell 5 are active. SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents). UE: PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108. Related ICS/IXIT statements - Compressed mode required yes/no Table 8.4.1.8-1 illustrates the dow...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.8.5 Test Requirement
After step 2, if UE requires compressed mode the UE shall not send any MEASUREMENT REPORT messages on the uplink DCCH of cell 1. If UE do not require compressed mode, the UE shall send a MEASUREMENT REPORT message on the uplink DCCH of cell 1. After step 4 and 8, UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPL...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.9 Measurement Control and Report: Unsupported measurement in the UE
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.9.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.9.2 Conformance requirement
If UTRAN instructs the UE to perform a measurement that is not supported by the UE, the UE shall: 1> retain the measurement configuration that was valid before the MEASUREMENT CONTROL message was received; 1> set the IE "RRC transaction identifier" in the MEASUREMENT CONTROL FAILURE message to the value of "RRC transac...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.9.3 Test purpose
1. To confirm that the UE transmits a MEASUREMENT CONTROL FAILURE message, with the value "unsupported measurement" in IE "failure cause" when the SS instructs the UE to perform an unsupported measurement by sending a MEASUREMENT CONTROL message. To confirm that the UE retains its existing valid measurement configurati...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.9.4 Method of test
Initial Condition System Simulator: 1cell UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. [Editor's note: It is assumed in this test that the UE under test does not possess any inter-RAT measurement capa...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.9.5 Test requirement
After step 2 the UE shall transmit a MEASUREMENT REPORT messages at 1 second interval. In these messages, the IE "CHOICE measurement" shall be set to "UE internal measured results", and it shall contain the measured UL transmitted power reading in IE "UE Transmitted Power". After step 4 the UE shall transmit a MEASURE...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.10 Measurement Control and Report: Failure (Invalid Message Reception)
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.10.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.10.2 Conformance requirement
If the MEASUREMENT CONTROL message contains a protocol error causing the variable PROTOCOL_ERROR_REJECT to be set to TRUE according to TS 25.331 clause 9, the UE shall perform procedure specific error handling as follows. The UE shall: 1> set the IE "RRC transaction identifier" in the MEASUREMENT CONTROL FAILURE messag...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.10.3 Test Purpose
1. To confirm that the UE continues its ongoing processes and procedures after it has received an invalid MEASUREMENT CONTROL message. 2. To confirm that the UE transmits MEASUREMENT CONTROL FAILURE message, after it has received an invalid MEASUREMENT CONTROL message.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.10.4 Method of test
Initial Condition System Simulator: 1 cell. UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. Test Procedure The UE is initially brought to CELL_DCH. SS transmits a MEASUREMENT CONTROL message to the UE, c...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.10.5 Test Requirement
After step 4 the UE shall transmit MEASUREMENT CONTROL FAILURE message, stating the IE "failure cause" as "protocol error" and IE "protocol error information" as "Message extension not comprehended". After step 5 the UE shall continue to send MEASUREMENT REPORT, with the measurement identity number set to 3 and "measur...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.11 Void
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.12 Void
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.13 Void
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.14 Measurement Control and Report: Cell forbidden to affect reporting range (FDD)
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.14.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.14.2 Conformance requirement
The reporting range affects the reporting events 1A and 1B. The reporting range is defined as a function of all the Primary CPICHs in the active set. If the parameter W is set to 0, the reporting range is defined relative to the best Primary CPICH. However, there could be cases where it is good to forbid a specific Pri...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.14.3 Test Purpose
1. To confirm that the UE reports the triggering of event 1A to the SS, if a primary CPICH currently measured by the UE enters the reporting range. 2. To confirm that the UE reports the triggering of event 1B to the SS, if a primary CPICH currently measured by the UE leaves the reporting range. 3. To confirm that the U...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.14.4 Method of test
Initial Condition System Simulator: 3 cells – Cell 1, cell 2 and cell 3 are active. SCH_Ec is set to 0 dB relative to CPICH_Ec. UE: CS-DCCH+DTCH _DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. Test Procedure Table 8.4.1...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.14.5 Test requirement
After step 1, the UE shall send a MEASUREMENT REPORT message on the uplink DCCH. The message shall contain the IE "Event results" to report that cell 2 has triggered intra-frequency event 1A. After step 3, the UE shall send a ACTIVE SET UPDATE COMPLETE message on the uplink DCCH. After step 5a, the UE shall transmit ME...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.15 Measurement Control and Report: Configuration Incomplete
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.15.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.15.2 Conformance requirement
If IE "Traffic volume measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE "measurement command" has the value "setup", but IE "Traffic volume measurement quantity" or IE "Traffic volume reporting quantity" is not received, the UE shall: 1> clear all stored measurement control information relat...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.15.3 Test Purpose
1. To confirm that the UE sends a MEASUREMENT CONTROL FAILURE message, after receiving a MEASUREMENT CONTROL message with IE "Measurement command" set to "Setup" and the following contents: - "CHOICE measurement type" IE is set to "Intra-frequency measurement" and "Intra-frequency measurement quantity" is omitted; or -...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.15.4 Method of test
Initial Condition System Simulator: 1 cell. UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. Test Procedure The UE is initially brought to CELL_DCH. SS then send a MEASUREMENT CONTROL message to UE. The U...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.15.5 Test Requirement
After step 1a, the UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH, reporting the RLC buffer payload of each RBs mapped on DCH at every 8s interval. After step 2, 4, 6, 8, 10, 12, 14 and step 16, the UE shall transmit MEASUREMENT CONTROL FAILURE message, stating the IE "failure cause" as "incomplete c...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.16 Measurement Control and Report: Traffic volume measurement for transition from idle mode to CELL_FACH state
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.16.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.16.2 Conformance requirement
Upon transition from idle mode to CELL_FACH state, the UE shall: 1> store the measurement control information from the IE "Traffic volume measurement system information" received in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11) in the variable MEASUREMENT_IDEN...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.16.3 Test Purpose
1. To confirm that after a state transition from idle mode to CELL_FACH state, the UE shall begin a traffic volume type measurement, as specified in System Information Block type 11 or 12 messages on BCCH. 2. To confirm that in CELL_FACH state, the UE shall send a MEASUREMENT REPORT message when reporting criteria is s...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.16.4 Method of test
Initial Condition System Simulator: 1cell UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7). Test Procedure The UE is initially in idle mode. The System Informat...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.16.5 Test Requirement
After step 5 the UE shall send MEASUREMENT REPORT messages on the uplink DCCH contain RLC buffer payload information for all SRBs. After 6 seconds UE shall send second MEASUREMENT REPORT messages contain RLC buffer payload information for all SRBs and RAB. After step 8 the UE shall overwrite measurement information rec...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.17 Measurement Control and Report: Traffic volume measurement for transition from idle mode to CELL_DCH state
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.17.1 Definition
8.4.1.17.2 Conformance requirement Upon transition from idle mode to CELL_DCH state, the UE shall: 1> begin a traffic volume type measurement, assigned in System Information Block type 11 (or System Information Block type 12. Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.17.3 Test Purpose
1. To confirm that after a state transition from idle mode to CELL_DCH state, the UE begin a traffic volume type measurement, as specified in System Information Block type 11 or 12 messages on BCCH. When entering CELL_DCH state, the UE shall send a MEASUREMENT REPORT message when reporting criteria is satisfied. 2. Du...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.17.4 Method of test
Initial Condition System Simulator: 1cell UE: "Registered idle mode on CS" (state 2) or "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mod...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.17.5 Test Requirement
After step 5, due to triggering of event 4B, the UE shall send MEASUREMENT REPORT message using unacknowledged mode of RLC. After step 7, UE shall send MEASUREMENT REPORT message using Acknowledged mode of RLC. After 8 seconds UE shall send second MEASUREMENT REPORT message. After step 10, the UE shall not send MEASUR...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.18 Measurement Control and Report: Traffic volume measurement for transition from CELL_FACH state to CELL_DCH state
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.18.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.18.2 Conformance requirement
Upon transition from CELL_FACH to CELL_DCH state, the UE shall: - retrieve each set of measurement control information of measurement type "traffic volume" stored; - if the optional IE "measurement validity" for this measurement has not been included: - delete the measurement; - if the IE "measurement validity" for the...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.18.3 Test Purpose
1. To confirm that the UE performs traffic volume measurements and the associated reporting when it enters CELL_DCH state from CELL_FACH state, and that such measurement contexts (and optionally, the reporting context) valid for CELL_DCH state have been previously stored. 2. To confirm that the UE shall continue to per...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.18.4 Method of test
Initial Condition System Simulator: 1 cell SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents). UE: PS-DCCH+DTCH_FACH (state 6-11) as specified in clause 7.4 of TS 34.108 Test Procedure Initially the UE is in CELL_FACH state. MEASUREMENT CONTROL message is sent to the UE to establish traffic volume measurem...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.18.5 Test Requirement
The UE shall send MEASUREMENT REPORT message in steps 21, 29 and 37. The UE shall not send MEASUREMENT REPORT message in steps 5, 8, and 13. 8.4.1.18a Measurement Control and Report: Traffic volume measurement for transition from Enhanced CELL_FACH state (common E-DCH in UL and HS-DSCH DL) to CELL_DCH state 8.4.1.18a.1...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.19 Measurement Control and Report: Traffic volume measurement for transition from CELL_DCH to CELL_FACH state
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.19.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.19.2 Conformance requirement
Upon transition from CELL_DCH to CELL_FACH or CELL_PCH or URA_PCH state, the UE shall: 1> retrieve each set of measurement control information of measurement type "traffic volume" stored in the variable MEASUREMENT_IDENTITY; and 2> if the optional IE "measurement validity" for this measurement has not been included: 3>...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.19.3 Test Purpose
1. The UE shall performs traffic volume measurements and the associated reporting when it enters CELL_FACH state from CELL_DCH state, and that such measurement contexts (and optionally, the reporting context) valid for CELL_FACH state have been previously stored. 2. The UE shall perform traffic volume measurement liste...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.19.4 Method of test
Initial Condition System Simulator: 1 cell SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents). UE: PS-DCCH+DTCH_DCH (state 6-10) as specified in clause 7.4 of TS 34.108 Test Procedure Initially the UE is in CELL_DCH state. MEASUREMENT CONTROL message is sent to the UE to establish traffic volume measuremen...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.19.5 Test Requirement
The UE shall send MEASUREMENT REPORT message in steps 13, 29 and 36. The UE shall not send MEASUREMENT REPORT message in steps 5, 8, and 21.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.20 Void
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.21 Void
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.22 Measurement Control and Report: Quality measurements
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.22.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.22.2 Conformance requirement
Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.6 unless otherwise specified below. The UE shall: 1> read the IE "Measurement command"; 1> if the IE "Measurement command" has the value "setup": 2> store this measurement in the variable MEASUREMENT_IDENTITY...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.22.3 Test Purpose
1. To confirm that the UE performs quality measurement as specified in MEASUREMENT CONTROL message received. In CELL_DCH state, the UE shall send MEASUREMENT REPORT message when the reporting criteria is fulfilled for any ongoing quality measurement.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.22.4 Method of test
Initial Condition System Simulator: 1 cell UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) as specified in clause 7.4 of TS 34.108, depending on the CN domain(s) supported by the UE. Test Procedure The UE is in CELL_DCH state. MEASUREMENT CONTROL message is sent to UE to assign quality measurement and...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.22.5 Test Requirement
In step 2 and 3, the UE shall send MEASUREMENT REPORT message to report BLER for downlink DCH transport channel.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
8.4.1.23 Measurement Control and Report: Intra-frequency measurement for events 1C and 1D