hash stringlengths 32 32 | doc_id stringlengths 5 12 | section stringlengths 5 1.47k | content stringlengths 0 6.67M |
|---|---|---|---|
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.3.5 Test requirement | After step 9, the UE shall transmit a CELL UPDATE message in Cell 24.
After step 24, the UE shall transmit a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message with the number of reported RLC SDUs shall be greater than zero.
After step 35, the UE shall transmit a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message w... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.4 MBMS Controlling Cell Change - Idle mode - Frequency Layer Convergence – With HCS / MBMS Selected Service | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.4.1 Definition | Test to verify that the UE performs the cell reselection correctly for hierarchical cell structures. This shall be done according to the HCS priority, the received signal quality value Q and the quality level threshold criterion H. This test case is applicable for all UEs that support MBMS broadcast services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.4.2 Conformance requirement | When camped normally, the UE shall perform the following tasks:
- select and monitor the indicated PICH and PCH of the cell as specified in clause 8 according to information sent in system information;
- monitor relevant System Information. This is specified in [8];
- perform necessary measurements for the cell reselec... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.4.3 Test purpose | 1. To verify that a UE in idle mode ranks cells based on both HCS priority and R. Qhyst, Qoffset and PENALTY TIME are not applied so R equals CPICH_RSCP.
2. To verify that a UE in idle mode performs a Serving Cell Reselection to the Preferred Layer at Session Start.
3. To verify that a UE in idle mode performs an intr... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.4.4 Method of test | Initial Condition
System Simulator: 3 MBMS cells (Cell 21, Cell 24, Cell 26) with the downlink transmission power shown in column marked "T0" in table 8.5.6.4-1.
SS shall indicate in System Information that HCS is in use. Qhcs = 0 so all cells fulfil the criterion H >=0.
Each cell shall include the other cells as neigh... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.4.5 Test requirement | At step 5, the UE shall respond on Cell 24.
At step 15, the UE shall respond on Cell 26.
8.5.6.4m MBMS Controlling Cell Change - Idle mode - Frequency Layer Convergence – With HCS / MBMS Multicast Service
8.5.6.4m.1 Definition
This test is applicable for all UEs that support MBMS multicast services.
8.5.6.4m.2 Conforma... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.5 MBMS Controlling Cell Change in CELL_DCH during ongoing session / MBMS Broadcast Service | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.5.1 Definition and applicability | This test case is applicable for all UEs that support MBMS broadcast services and support MBMS p-t-m reception in CELL_DCH state. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.5.2 Conformance requirement | The UE shall detect the available MBMS services by acquiring the MBMS MODIFIED SERVICES INFORMATION and the MBMS UNMODIFIED SERVICES INFORMATION messages without delaying reading of MCCH until the next modification period and without stopping at the end of the modification period, in accordance with subclause 8.7.1.3 o... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.5.3 Test purpose | 1. To verify that a UE in CELL_DCH state performs an inter-frequency MBMS Controlling Cell Change during an ongoing Session.
2. To verify that a UE in CELL_DCH state performs an intra-frequency MBMS Controlling Cell Change during an ongoing Session.
3. To verify that a UE in CELL_DCH is able to apply MBMS NEIGHBOURING ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.5.4 Method of test | Initial Condition
System Simulator:
3 MBMS cells, Cell 21, Cell 24 and Cell 26.
User Equipment:
The UE is in CELL_DCH state as specified in clause 7.6 of TS 34.108.
The UE is interested in the broadcast service to be provided by the SS (included in MBMS_ACTIVATED_SERVICES variable).
Related ICS/IXIT statement(s)
- MBMS... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.6.5.5 Test requirement | After step 7, the UE shall transmit a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message with the number of reported RLC SDUs shall be greater than zero.
After step 10, the UE shall transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message in Cell 24.
After step 15, the UE shall transmit a UE TEST LOOP MODE 3 RLC ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7 MBSFN Specific Procedures (FDD/TDD) | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.1 Cell Update: cell reselection in CELL_PCH (unicast carrier) during ongoing MBMS session in MBSFN mode | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.1.1 Definition | This test is applicable for UEs that support MBMS broadcast services in MBSFN mode and which support either both transmit and receive functions or MBSFN receive only function. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.1.2 Conformance requirement | The UE reception of MBMS services provided in MBSFN mode shall not affect the UE behaviour on the unicast carrier. Especially the UE mobility on the unicast carrier is not affected by the reception of MBMS services provided on a cell operating in MBSFN mode and can imply that the reception of the MBMS service on the ce... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.1.3 Test purpose | To verify that the UE will perform a Cell Update on the unicast carrier while receiving an ongoing MBMS service via a p-t-m radio bearer on the MBSFN cluster. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.1.4 Method of test | Initial condition
System Simulator:
- MBSFN carrier: 1 cell, Cell 31 (PLMN1). In addition to broadcasting System Information, MCCH messages are transmitted by the SS on Cell 31 using MBMS configuration C1 and Default1 MCCH scheduling (No ongoing session) according to subclause 11.2 of TS 34.108.
- Unicast carrier : 2 ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.1.5 Test requirements | 1) After step 9, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report a number > 0 for Cell 31 MTCH.
3) After step 11, the UE shall reselect to Cell 2 and transmit a CELL UPDATE message, containing the IE "Cell update cause" set to "cell reselection".
4) After step 13, the UE shall enter CELL_PCH state... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.2 Re-acquire MCCH - modified MBSFN inter frequency neighbour list / All MBSFN services notified | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.2.1 Definition | This test is applicable for UEs that support MBMS broadcast services in MBSFN mode and which support either both transmit and receive functions or MBSFN receive only function. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.2.2 Conformance requirement | Upon receiving the MBMS GENERAL INFORMATION message, the UE should store all relevant IEs included in this message. The UE shall also:
1> act upon all received information elements as specified in subclause 8.6, unless specified otherwise in the following.
…
For FDD 3.84 Mcps TDD IMB and 3.84/7.68 Mcps TDD if the IE "M... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.2.3 Test purpose | 1. To verify that the UE correctly re-acquires the MCCH information when the UE receives the IE MBMS re- acquire MCCH in a received MBMS MODIFIED SERVICES INFORMATION message.
2. To verify that the UE acts upon the modified IE MBSFN inter frequency neighbour list received in the re-acquired MBMS GENERAL INFORMATION mes... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.2.4 Method of test | Initial condition
System Simulator:
- MBSFN carrier: 3 cells, Cell 31, Cell 36 and Cell 38 (all PLMN1). Cell 36 and Cell 38 are powered off. In addition to broadcasting System Information, MCCH messages are transmitted by the SS on Cell 31 using MBMS configuration C1 and Default1 MCCH scheduling (No ongoing session) ac... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.2.5 Test requirements | 1) After step 15, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report that zero RLC SDUs have been received.
2) After step 18, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report that > 0 RLC SDUs have been received. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.3 Re-acquire MCCH - modified MBSFN inter frequency neighbour list / MBSFN services not notified | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.3.1 Definition | This test is applicable for UEs that support MBMS broadcast services in MBSFN mode and which support either both transmit and receive functions or MBSFN receive only function. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.3.2 Conformance requirement | Upon receiving the MBMS GENERAL INFORMATION message, the UE should store all relevant IEs included in this message. The UE shall also:
1> act upon all received information elements as specified in subclause 8.6, unless specified otherwise in the following.
…
For FDD, 3.84 Mcps TDD IMB and 3.84/7.68 Mcps TDD if the IE "... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.3.3 Test purpose | 1. To verify that the UE correctly re-acquires the MCCH information when the UE receives the IE MBMS re- acquire MCCH in a received MBMS MODIFIED SERVICES INFORMATION message.
2. To verify that the UE acts upon the modified IE MBSFN inter frequency neighbour list received in the re-acquired MBMS GENERAL INFORMATION mes... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.3.4 Method of test | Initial condition
System Simulator:
- MBSFN carrier: 3 cells, Cell 31, Cell 36 and Cell 38 (all PLMN1). Cell 36 and Cell 38 are powered off. In addition to broadcasting System Information, MCCH messages are transmitted by the SS on Cell 31 using MBMS configuration C1 and Default1 MCCH scheduling (No ongoing session) ac... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.3.5 Test requirements | For sub-test 1:
1) After step 15, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report a count > 0 for the number of RLC SDUs received.
2) After step 18, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report a count corresponding to zero RLC SDUs.
For sub-test 2:
1) After step 15, the U... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.4 MBSFN TDM Information / TDM services de-multiplexing | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.4.1 Definition | This test is applicable for UEs that support MBMS broadcast services in MBSFN mode and which support either both transmit and receive functions or MBSFN receive only function. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.4.2 Conformance requirement | For cells operating in MBSFN mode as indicated in subclause 8.1.1.6.3 upon receiving the MBMS CURRENT CELL P-T-M RB INFORMATION message, the UE shall act as specified in subclauses 8.7.5.3.
…
The UE applies the MBMS p-t-m radio bearer configuration procedure whenever it detects that one of the activated services is pro... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.4.3 Test purpose | 1. To verify that the UE correctly acquires the MCCH, when two services included in the variable MBMS_ACTIVATED_SERVICES are broadcast in a time division multiplexed fashion in the current MBSFN cluster.
2. To verify that the UE correctly acts upon the IE MBSFN TDM Information List received in the MBMS CURRENT CELL P-T... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.4.4 Method of test | Initial condition
System Simulator:
- MBSFN carrier: 1 cell, Cell 31 (PLMN1). In addition to broadcasting System Information, MCCH messages are transmitted by the SS on Cell 31 using MBMS configuration C1 and Default1 MCCH scheduling (one ongoing session) according to subclause 11.2 of TS 34.108.
- Unicast carrier : 1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.4.5 Test requirements | 1) After step 9, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report an SDU count = 0.
2) After step 12, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report an SDU count > 0.
3) After step 23, the UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE message shall report an SDU count = 0.
4) ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.5 MBSFN Session Reconfiguration / Change of MBSFN Cluster frequency on notification via MCCH (FDD) | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.5.1 Definition | This test is applicable for UEs that support MBMS broadcast services in MBSFN mode and which support either both transmit and receive functions or MBSFN receive only function. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.5.2 Conformance requirement | The UE applies the MCCH acquisition procedure to determine the MBMS services available in the cell and to initiate reception of the services that the UE has activated. The procedure applies to all UEs supporting MBMS, irrespective of their state (idle, URA_PCH, CELL_PCH, CELL_FACH and CELL_DCH).
…
The UE shall detect t... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.5.3 Test purpose | To verify that the UE correctly handles the notification procedure after receiving the MBMS MODIFIED SERVICES INFORMATION message via MCCH indicating a change in available services.
To verify that the UE acts upon service priority indications from upper layers that require a change in MBSFN cluster frequency.
To verify... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.5.4 Method of test | Initial condition
System Simulator:
- MBSFN carrier: 2 cells, Cell 31 and Cell 33, the tow cells are in deferent MBSFN cluster.
User Equipment:
- The UE is in MBSFN Idle mode with one activated service as specified in clause 7.6.4 of TS 34.108. The UE has selected (i.e. it is included in MBMS_ACTIVATED_SERVICES variabl... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.5.7.5.5 Test requirements | At step 4 the UE shall select new MBSFN Cluster and perform Cell Reselection from Cell 31 to Cell 33.
At step 12 the UE shall send a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE with a RLC SDU counter value greater zero. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6 Minimization of Drive Test Specific Procedures | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.1 Immediate MDT | NOTE: Immediate MDT logging and reporting is provided by the UE through normal measurement procedures (subclause 8.4). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2 Logged MDT | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.1 Logged MDT / Intra-frequency measurement, logging and reporting / Idle mode | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.1.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.1.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logge... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.1.3 Test Purpose | 1. Verify logging of configured Logged MDT measurements in Idle mode.
2. Verify logging and reporting of Logged MDT Intra-frequency measurements.
3. Verify indication of availability of Logged MDT measurements at RRC connection establishment.
4. Verify presence of correct time stamp in Logged MDT measurement reports. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.1.4 Method of test | Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active. Cell 1 and Cell 2 belongs to same PLMN, but have different Location Area Codes.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.1-1 illustrates the downlink power to be applied for ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.1.5 Test requirement | At step 10 the UE shall transmit a RRC CONNECTION SETUP COMPLETE message on uplink DCCH including the IE “Logged Meas Available” (TP3).
At step 12 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neigh... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.2 Logged MDT / Intra-frequency measurement, logging and reporting / CELL_PCH | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.2.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.2.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged mea... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.2.3 Test Purpose | 1. Verify logging of configured Logged MDT measurements in CELL_PCH state.
2. Verify logging and reporting of Logged MDT Intra-frequency measurements.
3. Verify indication of availability of Logged MDT measurements in CELL UPDATE message. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.2.4 Method of test | Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active.
SYSTEM INFORMATION BLOCK TYPE 4 (see specific message contents).
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.2-1 illustrates the downlink power to be applied for the 2 cells at ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.2.5 Test requirement | At step 6 the UE shall transmit a CELL UPDATE message on uplink DCCH including the IE “Logged Meas Available” (TP3).
At step 9 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.3 Logged MDT / Inter-frequency measurement, logging and reporting / URA_PCH | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.3.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.3.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged mea... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.3.3 Test Purpose | 1. Verify logging of configured Logged MDT measurements in URA_PCH state
2. Verify logging and reporting of Logged MDT Inter-frequency measurements
3. Verify indication of availability of Logged MDT measurements in URA UPDATE message |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.3.4 Method of test | Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 4 are active.
SYSTEM INFORMATION BLOCK TYPE 4 (see specific message contents).
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.3-1 illustrates the downlink power to be applied for the 2 cells at ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.3.5 Test requirement | At step 6 the UE shall transmit a URA UPDATE message on uplink DCCH including the IE “Logged Meas Available” (TP3).
At step 9 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 4 in the “Logged Measurements Inter Frequency Neighbouring Cells list” (... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.4 Logged MDT / Intra-frequency measurement, logging and reporting / Idle mode / Limiting area scope | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.4.1 Definition | This test is applicable for all UEs that support Logged MDT services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.4.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1, TP2, TP3)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.4.4 Method of test | Initial conditions
System Simulator:
3 cells, cell 1, cell 2 and cell 3.
User Equipment:
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
Table 8.6.2.4.4-1 illustrates the downlink power to be applied for the 3 cells. Column marked "T0" denotes the initial conditions, ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.4.5 Test requirements | At step 9, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present (TP1).
At step 18, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available” (TP1).
At step 21, the UE shall send an UE INFORMATION RESPONSE message with Logged... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.5 Logged MDT / Release of logged MDT measurement configuration / Expire of duration timer | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.5.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.5.2 Conformance requirement | [TS 25.331, clause 8.5.63.3 (TP1, TP2)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> st... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.5.3 Test Purpose | 1. Verify release of Logged MDT measurement configuration up on stop or expire of logging duration timer.
2. Verify that UE, when being requested to report logged MDT measurements before the duration timer has expired, deletes the reported logged MDT measurements. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.5.4 Method of test | Initial Condition
System Simulator: Cell 1 is active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits an RRC CONNEC... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.5.5 Test requirement | At step 11, the UE shall send an UE INFORMATION RESPONSE message, without IE “Logged Meas Report” (TP2).
At step 24, the UE shall transmit a RRC CONNECTION SETUP COMPLETE message, without IE “Logged Meas Available” (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.6 Logged MDT / Release of logged MDT measurement configuration / Reception of new logged measurement configuration, Detach or UE power off | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.6.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.6.2 Conformance requirement | [TS 25.331, clause 8.5.63.3 (TP1, TP2)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> st... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.6.3 Test Purpose | 1. Verify release of logged measurement configuration and logs up on reception of new logged measurement configuration
2. Verify release of logged measurement configuration and logs upon UE switch off or detach |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.6.4 Method of test | Initial Condition
System Simulator: Cell 1 is active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Related ICS/IXIT statement(s)
Switch off button Yes/No.
Test Procedure
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to c... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.6.5 Test requirement | At step 10, the UE shall send a UE INFORMATION RESPONSE message, without IE “Logged Meas Report” (TP1).
At step18, the UE shall send a UE INFORMATION RESPONSE message, with IE “Logged Meas Report”. And the IE “Logged Meas Report” does not include logged measurement reports based on the message LOGGING MEASUREMENT CONFI... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.7 Logged MDT / Maintaining logged measurement configuration / UE state transitions and mobility | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.7.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.7.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1, TP2, TP3, TP4)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuratio... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.7.3 Test Purpose | 1. Verify that UE is not indicating availability of Logged MDT measurements when UE has moved to a non MDT PLMN cell
2. Verify that logged measurement configurations and logs are maintained despite periods of interruptions due to UE transitions to CELL_FACH or CELL_DCH
3. Verify that logged measurement configurations a... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.7.4 Method of test | Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.7 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the in... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.7.5 Test requirement | At step 6, the UE shall transmit a CELL UPDATE message without the IE "Logged Meas Available" on Cell 2 (TP1).
At step 10, the UE shall transmit a CELL UPDATE message with the IE "Logged Meas Available" set as TRUE on Cell 3 (TP3).
At step 19, the UE shall transmit a UE INFORMATION RESPONSE message, with IE “Logged Mea... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.8 Logged MDT / Reporting / Location information | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.8.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.8.2 Conformance requirement | [TS 25.331, clause 8.5.65.2]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.8.3 Test Purpose | 1. Verify presence of location information in Logged MDT measurement reports. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.8.4 Method of test | Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
The UE's positioning engine (e.g. standalone GNSS receiver) should be provided with any necessary stimulus to allow it to provide the position. This shall be do... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.8.5 Test requirement | Test step numbers as per expected sequence table in subclause 8.6.2.1.4.
At step 12 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” with the IE Ellipsoid point or IE Ellipsoid... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.9 Logged MDT / Logging and reporting / PLMN list / PLMN change | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.9.1 Definition | This test is applicable for all UEs that support Enhancement of Logged MDT services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.9.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logge... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.9.4 Method of test | Initial conditions
System Simulator:
3 cells, cell 1, cell 2 and cell 3.
User Equipment:
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
Table 8.6.2.9 illustrates the downlink power to be applied for the 3 cells. Column marked "T0" denotes the initial conditions, whil... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.2.9.5 Test requirements | At step 11, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present (TP1).
At step 20, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available” (TP2).
At step 23, the UE shall send an UE INFORMATION RESPONSE message with Logge... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3 Inter-RAT Logged MDT |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.