hash stringlengths 32 32 | doc_id stringlengths 5 12 | section stringlengths 5 1.47k | content stringlengths 0 6.67M |
|---|---|---|---|
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.1 Logged MDT / E-UTRAN Inter-RAT measurement, logging and reporting / Idle mode | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.1.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.1.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged mea... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.1.3 Test Purpose | 1. Verify logging and reporting of Logged MDT E-UTRAN Inter-RAT measurements |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.1.4 Method of test | System Simulator: 1 UTRAN FDD cell (or TDD cell) and 1 E-UTRAN cell. Cell 1 is a UTRAN cell, and Cell 2 is an E-UTRAN Cell. Cell 2 configuration refers to “Cell 1” in TS36.508 clause 6.3. SIB configuration 6 is applied in accordance with TS 34.108 clause 6.1.0a.2.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1as specifie... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.1.5 Test requirement | At step 15, the UE shall transmit a UE INFORMATION RESPONSE message, with IE “Logged Measurements Inter-RAT Neighbour cells list” include Logged Measurements of Cell 2 (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.2 Logged MDT / GERAN Inter-RAT measurement, logging and reporting / Idle mode | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.2.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.2.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged mea... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.2.3 Test Purpose | 1. Verify logging and reporting of Logged MDT GERAN Inter-RAT measurements |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.2.4 Method of test | Initial Condition
System Simulator: 2 cells – cell 1 and cell 9 are active. Cell 1 is UTRA FDD or TDD cells. Cell 9 is GSM cell. The PLMN of Cell 1 and Cell 9 are the same.
UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.3.2-1and Table 8.6.3.2-2 illustrates ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.2.5 Test requirement | At step 15, the UE shall transmit a UE INFORMATION RESPONSE message, with IE “Logged Measurements Inter-RAT Neighbour cells list” include Logged Measurements of Cell 9 (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.3 Logged MDT / Maintaining logged measurement configuration / UTRAN to E-UTRAN Inter-RAT mobility | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.3.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.3.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logge... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.3.3 Test Purpose | 1. Verify indication of availability of Logged MDT measurements in HANDOVER TO UTRAN COMMAND message.
2. Verify that logged measurement configurations and logs are maintained despite periods of interruptions due to UE transitions to E-UTRAN. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.3.4 Method of test | System Simulator: 1 UTRAN FDD cell (or TDD cell) and 1 E-UTRAN cell. Cell 1 is a UTRAN cell, and Cell 2 is an E-UTRAN Cell. Cell 2 configuration refers to “Cell 1” in TS 36.508 clause 6.3.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Related ICS/IXIT statements
- Compressed mode ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.3.5 Test requirement | At step 20, the UE shall transmit a HANDOVER TO UTRAN COMPLETE message, with the IE "Logged Meas Available" on Cell 1 (TP1).
At step 24, the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 1 and Cell 2 (TP2). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.4 Logged MDT / Maintaining logged measurement configuration / UTRAN to GERAN Inter-RAT mobility | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.4.1 Definition | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.4.2 Conformance requirement | [TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged mea... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.4.3 Test Purpose | 1. Verify indication of availability of Logged MDT measurements in HANDOVER TO UTRAN COMMAND message.
2. Verify that logged measurement configurations and logs are maintained despite periods of interruptions due to UE transitions to other RAT. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.4.4 Method of test | Initial Condition
System Simulator: 2 cells – cell 1 and cell 9 are active. Cell 1 is UTRA FDD or TDD cells. Cell 9 is GSM cell. The PLMN of Cell 1 and Cell 9 are the same.
UE: CELL_DCH (state 6-9) in cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.3.4-1
Parameter
Unit
Cell 1 (UTRA)
T0
T1
T2
UT... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.3.4.5 Test requirement | At step 33, the UE shall transmit a HANDOVER TO UTRAN COMPLETE message, with the IE "Logged Meas Available" on Cell 1 (TP1).
At step 37, the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 1 and Cell 9 (TP2). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4 Connection Establishment Failure | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.1 Connection Establishment Failure logging / Logging and reporting / T300 expiry | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.1.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.1.2 Conformance requirement | [TS 25.331, clause 8.1.3.5 (TP1)]
1> if the UE has not yet received an RRC CONNECTION SETUP message with the value of the IE "Initial UE identity" equal to the value of the variable INITIAL_UE_IDENTITY; and
1> if cell re-selection or expiry of timer T300 or timer T318 occurs:
the UE shall:
1> if the UE performs cell re... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.1.4 Method of test | Initial conditions
System Simulator:
Cell 1
User Equipment:
UE: Registered Idle Mode on PS (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
The UE sends RRC CONNECTION REQUEST message to SS, and SS does not response any message to UE.
The UE resubmits RRC CONNECTION REQUEST message 3 times an... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.1.5 Test requirements | At step 10, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available".(TP1,TP2).
At step 12, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1. (TP1, TP3). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.2 Connection Establishment Failure logging / Logging and reporting / Physical channel failure | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.2.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.2.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP2)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
...
1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.2.3 Test Purpose | 1. Verify that Connection Establishment Failure information is logged when Physical channel failure is occurred and V300 is greater than N300.
2. Verify that IE "Logged Connection Establishment Failure Info Available" is indicated at RRC connection establishment. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.2.4 Method of test | Initial conditions
System Simulator:
Cell 1
User Equipment:
UE: Registered Idle Mode on PS (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
SS transmits a Paging message.
The UE sends RRC CONNECTION REQUEST message to SS, and SS send a RRC CONNECTION SETUP message to UE without physical chann... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.2.5 Test requirements | At step 9, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available" (TP2).
At step 11, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1 (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.3 Connection Establishment Failure logging / Logging and reporting / Invalid RRC CONNECTION SETUP message | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.3.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.3.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP2)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
...
1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.3.4 Method of test | Initial conditions
System Simulator:
Cell 1
User Equipment:
UE: Registered Idle Mode on PS (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
SS transmits a Paging message.
The UE sends RRC CONNECTION REQUEST message to SS, and SS send a RRC CONNECTION SETUP message to UE with a unsupported fre... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.3.5 Test requirements | At step 9, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available".( TP2).
At step 11, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.4 Connection Establishment Failure logging / Logging and reporting / RRC CONNECTION REJECT message | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.4.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.4.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP1, TP2)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.4.3 Test Purpose | 1. Verify that Connection Establishment Failure information is logged when RRC CONNECTION REJECT message is received and V300 is greater than N300.
2. Verify that IE "Logged Connection Establishment Failure Info Available" is indicated at RRC connection establishment. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.4.4 Method of test | Initial conditions
System Simulator:
Cell 1
User Equipment:
UE: Registered Idle Mode on PS (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
SS transmits a Paging message.
The UE sends RRC CONNECTION REQUEST message to SS, and SS send a RRC CONNECTION REJECT message to UE.
Repeats last procedu... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.4.5 Test requirements | At step 9, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available" (TP2).
At step 12, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1 (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.5 Connection Establishment Failure logging / Logging and reporting / Invalid RRC CONNECTION REJECT message | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.5.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.5.2 Conformance requirement | [TS 25.331, clause 8.1.3.10(TP1)]
If the UE receives an RRC CONNECTION REJECT message which contains an IE "Initial UE identity" with a value which is identical to the value of the IE "Initial UE identity" in the most recent RRC CONNECTION REQUEST message sent by the UE; but the RRC CONNECTION REJECT message contains a... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.5.3 Test Purpose | 1. Verify that Connection Establishment Failure information is logged when Invalid RRC CONNECTION REJECT message is received and V300 is greater than N300.
2. Verify that IE "Logged Connection Establishment Failure Info Available" is indicated at RRC connection establishment. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.5.4 Method of test | Initial conditions
System Simulator:
Cell 1
User Equipment:
UE: Registered Idle Mode on (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
SS transmits a Paging message.
The UE sends RRC CONNECTION REQUEST message to SS, and SS send a RRC CONNECTION REJECT message with protocol error to UE.
Rep... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.5.5 Test requirements | At step 9, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available".( TP2).
At step 12, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.6 Connection Establishment Failure logging / Logging and reporting / PLMN change | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.6.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.6.2 Conformance requirement | [TS 25.331, clause 8.1.3.5 (TP1, TP2)]
1> if the UE has not yet received an RRC CONNECTION SETUP message with the value of the IE "Initial UE identity" equal to the value of the variable INITIAL_UE_IDENTITY; and
1> if cell re-selection or expiry of timer T300 or timer T318 occurs:
the UE shall:
1> if the UE performs ce... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.6.3 Test Purpose | 1. Verify that IE "Logged Connection Establishment Failure Info Available" is not indicated in the cell that does not belong to the PLMN where RRC connection establishment failure was occurred.
2. Verify that IE "Logged Connection Establishment Failure Info Available" is indicated in the cell that belongs to the PLMN w... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.6.4 Method of test | Initial conditions
System Simulator:
3 cells, cell 1, cell 2 and cell 3.
User Equipment:
UE: Registered Idle Mode on PS (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
Table 8.6.4.6 illustrates the downlink power to be applied for the 3 cells. Column marked "T0" denotes the initial condition... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.6.5 Test requirements | At step 17, the UE should transmit an RRC CONNECTION SETUP COMPLETE message, and IE "Connection Establishment Failure Info Available" not presents. (TP1)
At step 19, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available". (TP2).
At step 20, The UE ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.7 Connection Establishment Failure logging / Logging and reporting / location information | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.7.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.7.2 Conformance requirement | [TS 25.331, clause 8.1.3.11(TP1)]
If the RRC connection establishment fails and the UE supports logging of failed RRC Connection Establishment, the UE shall perform logging of information for later retrieval. The UE shall store connection establishment failure information in the variable LOGGED_CONNECTION_ESTABLISHMENT... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.7.3 Test Purpose | 1. Verify presence of location information in RLF measurement, triggered by RRC connection establishment failure, is reported in connection establishment failure information in UE INFORMATION RESPONSE message. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.7.4 Method of test | Initial Condition
System Simulator:
Cell 1
User Equipment:
UE: Registered Idle mode on PS (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
The UE's positioning engine (e.g. standalone GNSS receiver) should be provided with any necessary stimulus to allow it to provide the position. This shall be done by use... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.7.5 Test requirement | At step 12, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report including location information on cell 1. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.8 Connection Establishment Failure logging / Logging and reporting / Intra-frequency measurements | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.8.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.8.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP1)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
...
1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.8.4 Method of test | Initial conditions
System Simulator:
2 cells, Cell 1 and Cell 2
User Equipment:
UE: Registered Idle mode (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.4.8 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.8.5 Test requirements | At step 13, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 2 and include the "Logged Measurements Intra Frequency Neighbouring Cells list" with Cell 1 information in the Report. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.9 Connection Establishment Failure logging / Logging and reporting / Inter-frequency measurements | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.9.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.9.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP1)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
...
1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.9.3 Test Purpose | 1. Verify that inter-frequency neighbour cell information (IE "Logged Measurements Inter Frequency list") is reported in connection establishment failure information in UE INFORMATION RESPONSE message. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.9.4 Method of test | Initial conditions
System Simulator:
2 cells, Cell 1 and Cell 4
User Equipment:
UE: Registered Idle mode (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Table 8.6.4.8 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.4.9.5 Test requirements | At step 13, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 4 and include the "Logged Measurements Inter Frequency Neighbouring Cells list" with Cell 1 information in the Report. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5 Inter-RAT Connection Establishment Failure | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.1 Connection Establishment Failure logging / Reporting at E-UTRAN inter-RAT handover | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.1.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.1.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP1)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
...
1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.1.3 Test Purpose | 1. Verify that IE "Logged Connection Establishment Failure Info Available" is indicated at inter-RAT handover to UTRA. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.1.4 Method of test | Initial conditions
System Simulator:
2 cells, 1 UTRAN FDD cell (or TDD cell) and 1 E-UTRAN cell. Cell 1 is a UTRAN cell, and Cell 2 is an E-UTRAN Cell. Cell 2 configuration refers to “Cell 1” in TS36.508 clause 6.3. SIB configuration 6 is applied in accordance with TS 34.108 clause 6.1.0a.2
User Equipment:
UE: state R... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.1.5 Test requirements | At step 23, The UE shall send HANDOVER TO UTRAN COMPLETE message to SS, and include IE “Connection Establishment Failure Info Available” as True (TP1).
At step 27, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.2 Connection Establishment Failure logging / Logging and reporting / E-UTRA Inter-RAT measurements | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.2.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.2.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP1)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
...
1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.2.4 Method of test | Initial conditions
System Simulator:
2 cells, Cell 1 and Cell 2(E-UTRA)
User Equipment:
UE: Registered Idle mode (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
Table 8.6.5.2 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column m... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.2.5 Test requirements | At step 16, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1 and include the "Logged Measurements E-UTRA Frequency Neighbours List" with Cell 2 information in the Report. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.3 Connection Establishment Failure logging / Logging and reporting / GERAN Inter-RAT measurements | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.3.1 Definition | This test is applicable for all UEs that support Connection Establishment Failure logging services. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.3.2 Conformance requirement | [TS 25.331, clause 8.1.3.6 (TP1)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
...
1... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.3.4 Method of test | Initial conditions
System Simulator:
2 cells, Cell 1 (UTRAN) and Cell 9(GERAN)
User Equipment:
UE: Registered Idle mode (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
Table 8.6.5.3-1 and table 8.6.5.3-2 illustrate the downlink power to be applied for the 3 cells at various time instants of ... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.6.5.3.5 Test requirements | At step 24, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1 and include the “Logged Measurements GSM Neighbouring Cells list” with Cell 9 information in the Report. (TP1). |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.7 Automatic Neighbour Relation (ANR) for UTRAN | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.7.1 Intra-UTRAN | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.7.1.1 Intra-UTRA / Intra-frequency ANR measurement, logging and reporting in IDLE Mode / RSCP Absolute Threshold | |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.7.1.1.1 Definition and applicability | All UEs supporting UTRA FDD or UTRA TDD and UTRAN ANR measurements. |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.7.1.1.2 Conformance requirement | [TS 25.304, clause 5.8.1 (TP3)]
The UE may be configured to perform UTRAN ANR measurement and logging in IDLE mode, CELL_PCH and URA_PCH state with Logging Measurement Configuration message as specified in [4]. If configured, the UE will
- perform measurements and evaluation on the cells which are not included in the n... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.7.1.1.3 Test purpose | 1. Verify that UE signals capability "Support of UTRAN ANR".
2. To verify that the UE correctly reads “Logged ANR configuration Info” in LOGGING MEASUREMENT CONFIGURATION message for Intra-UTRA ANR case when Absolute Threshold for RSCP is configured.
3. To verify that the UE trigger and performs ANR measurements on a c... |
4251e2eb3ecde7c73983ce7a4175ddf3 | 34.123-1 | 8.7.1.1.4 Method of test | Initial Condition
System Simulator: 3 FDD or TDD cells – cell 1, cell 2 and cell 3 are active.
SYSTEM INFORMATION BLOCK TYPE 11 of Cell 1: See specific message contents.
NOTE: Cell 2 is listed as intra-frequency neighbour cell. Cell 3 is not included in the intra-frequency or inter-frequency cell info lists.
SS sets th... |