text
stringlengths
38
9.81k
<s>[INST] MD60 No life. Lost ground while operating Summary: MD60 signal phase lost groundwhile operatingI have an 6MDAN-4P5101, single phase, 240v 1 HP. It has run regularly in my shop for 5 years. I lost the ground line while it was operating. I heard I small pop and now it doesn't do anything. I have cycled power an...
<s>[INST] View Designer issue. How can I create internal HMI tag in View Deisinger. [/INST] I don't believe it is possible to create an internal HMI tag in View Designer. This software is entirely different than FT View ME/SE, so some of the features you may be accustomed to don't necessarily exist here. Not yet, at le...
<s>[INST] Communications Hey guys: do you kwon any cause why cannot communicate with a Ultra3000i even if I check all communications parameters, port settings and RSLinx Classic and Enterprise are shutdown?? [/INST] Sabre, following some technotes that may help... Aid 47739Aid 49520Aid 34935Aid 46489 Hope this helps......
<s>[INST] Powerflex 525 Summary: Not receiving Drive Ready StatusWhen I reset my e-stop signal going to drive, I'm getting 'network ok' signal from the VFD but not the drive ready status within a particular amount of time, say 6 sec. I'm using CPS command to get the status. The ethernet is working fine. Any lead will h...
<s>[INST] 1756-L83ES wipe or unlock safety Processor. I've got an upgrade on an existing CPU System problem is the customer has changed the safety Unlock password and doesn't know what it is, and I need to make edits in the safety software. So, the question I have is there a way to brute force the safety open or wipe t...
<s>[INST] SEW AS7W with PF755 and CIP Motion Summary: Is the AS7W compatible with PF755 and CIP Motion?I have been supplied several SEW motor gearboxes fitted with AS7W encoders instead of the expected AS7Y, they are to be used with PF755 / UFB-1 and CIP Motion. SEW has told me that the AS7W is a Hyperface encoder. I h...
<s>[INST] PowerFlex70 and 20CommE We have PF70 drives that are configured to be controlled via the 20CommE module on Ethernet. Works well.In anticipation of a network or PLC crash, can the drive be configured to also respond to hardwired inputs, (start, stop, run at a preset speed) in order to accomodate the emergency ...
<s>[INST] Command vs. actual position glitch on virtual axis I was wondering if anyone else had run into an issue where .CommandPosition doesn't equal .ActualPosition on a virtual axis. The Rockwell documentation states that a virtual axis doesn't have an actual position, so .ActualPosition returns the same value as .C...
<s>[INST] Issue with an A-B PowerFlex 753 Summary: Event DigIn Cfg B, DI Run and DI Fwd Reverse at the same time shouldn't be an issueHi, I installed a PF 753 (20F-11ND052AA0NNNNN) Firmware: v2.007.37 with a 24V DC 22-Series I/O Module (20-750-2262C-2R) on slot 4 Configured: DI Stop on Port 0: Dig In Sts.Digital In 1 D...
<s>[INST] 700S JOG 1, JOG 2 I have a 700S which has the add on encoder board. The drive is setup to follow the auxiliary encoder encoder with the application of a run input (2 wire). My customer asked me to install a FWD/REV Jog cct. on this application. I setup JOG 1 and JOG 2 on digital inputs 1 and 2, JOG 1 setpoint...
<s>[INST] Powerflex Drive Support on RSLogix Architect Summary: I am using RSLogix Architect V3.6 but i could not import or export powerflex drives to or from RSLogix 5000.Is this feature available with any of the RSlogix Architect versions. [/INST] Hi, Drive support is also not available in RSLogix Architect V20. Plea...
<s>[INST] Aux encoder with K5500 I need to add a linear encoder to a Kinetix 5500 axis, controlled by a 1769-L33ERM. The 5500 has no auxiliary feedback input so my plan is to use the 1769-HSC to input the encoder signal. I would like some suggestions on how to program the linear scale. One thought I had was to take the...
<s>[INST] SMC-50 Underload Fault Reset Summary: Cannot reset Using PLC tag, but can reset using drive tab or keypadHello. I am having an issue with a SMC-50 Soft start. The drive has been added to the IO tree of an rslogix application and I can communicate to the drive and I can see status information and also set up c...
<s>[INST] PowerFlex70 EC Drives via Ethernet Anyone know the whereabouts in the documentation to calculate the packets per second (PPS) or CIP/TCP connections for a 20-Comm-E adapter? Trying to get a handle on configuring 40 PFlex70 drives on a ControlLogix system. I know it depends on the RPI but not sure about the 20...
<s>[INST] Powerflex 40 smoking, but working... Hi.We have an application with about 20 VFD's (PF40 and 400) up and running OK for 3 years.One day the operator noticed that smoke (a lot) where coming out from one of the PF40's, he tripped the EM stop to cut power to the drive. The drive was stopped (motor NOT running) a...
<s>[INST] Max. Motor cable length with/without AC line Filter for Kinetix 5700 Hi everyone, I am using MPM-B1653F-MJ7AAA ( quantity - 1 ) connected with kinetix 5700 2198-S086-ERS3 single axis inverter (quantity - 1). VPL-B115E-PK14AS ( quantity - 6 ) connected with kinetix 5700 2198-D020-ERS3 dual axis inverter (quant...
<s>[INST] 1336F-b050 Drive Summary: stop drive after 20 minutesWe would like to stop drive after 20 minutes. But this drive is in a stand alone system connected to the pump itself. It has a HIM display, but no TB3 board. What I was going to do is add a timing relay inside and remove the enable after 20 minutes. So here...
<s>[INST] Controlling position on Ultra 3000 I want to be able to control the position of the motor by giving the drive a specific count. Presets positions restrict me to having only 8 position however I would like to be able to move the drive to a specific position. The psoition count will be eventually generated by a...
<s>[INST] Error 'Catastrophic failure' during installing Ultraware v1.64 I have installed Ultraware 1.63 long time ago. This software warning me that 'Unable to open Ultraware local machine registry key. You may need to reinstall Ultraware' So I download the Ultraware v1.64 from rockwell automation software site. But t...
<s>[INST] PowerFlex 523 Seria A x Serie B Analog Input An OEM was building air compressors using Powerflex 523 Serie A with a Pressure Transducer 4-20mA (2 wire) as a PID feedback connected to pins 11 (+24VDC) and 15 (4-20mA input). Now with Series B is connecting to 11 (24VDC) and 13 (Analog Input) but it is not worki...
<s>[INST] How to setup the config between micrologix 1200 - ENI-Interface module and HMI PANEL VIEW PLUS. My problem is my 3 device are in the network I can ping. but for any reazon the HMI don't see the plc. I setup the topic in the HMI proyect but the problem persisting. I used Micrologix 1200, ENI-interface module, ...
<s>[INST] Camming I have a PowerFlex DC Drive that I need a Kinetix 6000 Drive and/or motor to cam off of. PowerFlex DC can't be set up as axis so best approach please. [/INST] Your question implies that your DC motor has an encoder. If so, you're in luck but not the way you think. If it's an incremental encoder, I rec...
<s>[INST] Disable Hw limit Switches control Hi all, I need a way to enable/disable the hardware limit switches of a CIP axis via software like a MSG or SSV or something like that. Do you know if exist a way? The axis type is Kinetix 5500 Best regards. [/INST] See technote QA28637. (Requires TechConnect) If you don't ha...
<s>[INST] SMC Flex Par 50 Are the thermistor inputs used to calculate the %MTU ? , and if so can Par 50 be adjusted to give a trip point ? [/INST] MTU is motor thermal usage and is a mathematical model that simulates the amount of heat generated in a motor due to current draw over time. It is based on an I^2T algorigth...
<s>[INST] 1756-M02AS Axis Feedback Problems We have a control logix system, using version 13.04. We have a MTS temposonic linear probe that we have connected to a 1756-M02AS card and using feedback only for a display of the position. This works great until the power is removed from the control logix rack for whatever r...
<s>[INST] Kinetix and Mitsubishi compatibility Good morning. I am working on a retro fit of an older machine for my employer. The question I have, and can't seem to find the answer to is this: We have a machine that was previously controlled by all mitsubishi products and it was flooded. So the PLC, Servo drive is toas...
<s>[INST] Powerflex 400 heat sink overtemp What else would be causing this issue besides the description in the book? This is a new drive, it has only been running for less than 24hrs when we started having this issue....I have reviewed all the info in the menues and they seem to match what is on the name plate..... [/...
<s>[INST] Kinetix 5100 Hi All, Does anyone know if it is possible to read the digital input status of a Kinetix 5100 servo drive? Regards, Ian [/INST] It looks like you can MSG the drive to get information https://literature.rockwellautomation.com/idc/groups/literature/documents/um/2198-um004_-en-p.pdf tells you how to...
<s>[INST] Powerflex 523 Ready and Digital In Feedback Summary: Ready and Digital In Status not working I have 52 Powerflex 523's on an Ethernet network using 523-E2P modules and DLR for the network. The drives are connected to an EN2TR module on the Control Logix Rack. PLC is L62 V20.12 EN2TR module is V4.4 Powerflex A...
<s>[INST] Can't add PowerFlex 700 to my project Summary: Module profile not installed. Error 8609-0Hi, I am starting a new RSLogix 5000 (v19) project where I will be using several PowerFlex 700 Vector drives. I have done this before, but I have switched to a new laptop since that time. Now, when I try to add the PowerF...
<s>[INST] SMC-3 delta Summary: 230v - 400v hi all, I have a motor: 22 kw - 230v. delta / 400v. star . Can I use a SMC-3 delta soft starter to run the motor with different voltage 230v and 400v, using contactors to make the delta or star configuration? and if I can do it, which is the better switch configuration to have...
<s>[INST] coping parameter from a powerflex to be stored on a pc Summary: I need to be able to store drive parameters on my pc networkWe have over 400 differant powerflex drives from 4 to 700s We need to be able to back up the parameters so we can use the copycat function to reinstall the parameters when a drive fails ...
<s>[INST] CompactLogix 5380 question. When I type the IP address of the PLC in Chrome a web server appears. Is there a way to see tag values here? [/INST] Unfortunately, no\n </s>
<s>[INST] How to compare two projects AOI automatically or easy way to understand changes? [/INST] Compare & Merge tool.\n </s>
<s>[INST] IAB question - multiple drives Is there a way to copy devices in IAB? I configured a PF700 DeviceNet drive in IAB. My application has 25 drives. I really don't want to configure each of them separately. I have not found a way to copy. Does anyone know if this can be done or if there is a work around? Thanks! ...
<s>[INST] PowerFlex 70 Jog Speed Reference I want to modify the jog speed over HMI via PLC + Ethernet. The system works fine with start, stop, jog … commands, and change speed over HMI, but can’t change jog speed. I went through the manual and this board can't find the answer about this function. Does any one know how ...
<s>[INST] Release date (just year) of Allen Bradley 2540AB Hi,It`s very important for me to understand the year of manufacturing of this computer.There is no year on the labels and there is not other labels. Ideas? http://picasaweb.google.bg/116078238941018557966/AlB [/INST] I'm afraid I'm unable to find out anything a...
<s>[INST] Load Sharing in DC Powerflex Hello to everyone. I have 3 old DC Drivers running on load sharing (paper machine). These old drivers have Load Sharing function, but these function need to be turned on manualy (relay). The bigger motor are 400 HP for yankee dryer, 300HP for cylinder dryer and 150HP for crescent ...
<s>[INST] Kinetix 5100, disconnect encoder without fault Hello, I would like to know if it is possible, by ethernet ip, to disable the kinetix 5100 drive, it is to be able to disconnect the encoder (through an ATI tool changer), so that, while it is energized, to be able to make the change, and it does not cause an non...
<s>[INST] Rslogix5000 V17 - Additional Axis Servo faults Axis00.Guard..... What do they mean? In Rslogix5000 V17 there are a whole bunch of additional servo axis faults added. Nobody within Rockwell Europe knows what they mean (I asked esupport and they still owe me an answer).I need to explain to my client what they m...
<s>[INST] Motor Encoder Connector on U3000 Since my motor encoder do not have pinout of overtravel limit, I leave +LIMIT/-LIMIT pins open on CN2. After I startup the driver, there is an Error Code L flashing which means the drive is in overtravel condition. The manaual indicates that the motion will be halt if +LIMIT/-...
<s>[INST] 1305 how do I program a 1305 to run on power up? I have set this parameter to enable - what else needs to be changed? [/INST] This applies only when there is a maintained input to the start and stop inputs. Refer to User Manual, Chapter 2, Figure 2.7 through Figure 2.10. Hope this helps, - fuzzy logic \\n </s...
<s>[INST] Kinetix 350 Active Homing Summary: MAH ends in ERR 84 - Drive Digital Input Not AssignedI am setting up a new application using older components: ControlLogix 1756-L63 CPU rev 20.11, 1756-EN2T Ethernet/IP card, RSLogix 5000 v20.01, Kinetix 350 rev 1.55. This is an upgrade of a system we had with a SLC500 and ...
<s>[INST] SMC Flex Help Hello Friends, I am using about 30 number of 150-SMC-Flex devices on DeviceNet with 20-COMM-D Series-B module. I have installed the modules and the LEDs PORT/MOD/NET-A are steady Green. I have programmed the 150-SMC-Flex for Soft Start and Soft Stop Parameters. I am trying to give DeviceNet Out ...
<s>[INST] ArmorStart 284D Summary: Wiring Diagram I am working with the 284D armorstart and am wondering where to find a internal wiriing diagram for the unit. I specifically I want to know where the control power wires go inside the ArmorStart. The OEM that did the hardware layout did not follow the pin outs for this ...
<s>[INST] PowerFlex 40 (or 523) Keypad Control with Start at Powerup Hi All, I have a contractor who's customer builds machines that used TB Woods drives. We are converting them over to PowerFlex, but one feature that they used in the TB Woods was a setting that allowed them to have both keypad control with the ability...
<s>[INST] PF400 comms loss problem client has 4 x 250kW PF400 units with 22commD and 22Him3cs door mounted HMI. As soon as I plug the HIMM in, the drive trips on “Comms Loss”. Reset the drive, fault re-appears within a few seconds. Leave HIMM plugged out – no problem then. have flased the 22commD to latest firmware as ...
<s>[INST] Welcome to Engage, A Rockwell Automation Community--Rockwell Automation Staff Thank you for your interest in Engage! As a Rockwell employee, you can participate in this modern, customer-facing platform experience in which Rockwell staff, customers, prospects, partners, and others can share knowledge, best pra...
<s>[INST] MPL B320P-R Hook and Tune problem. Hallo. I am building some kind of manipulator with this servo motors. And now it's time when I need help. I try to do Test Marker (ok), test feedback (ok), but Test Command cannot be completed , motor start and does one rev. and then is a information Test Command cannot be c...
<s>[INST] Where are the CAM points stored? In a system I've got a virtual axis and a physical axis. Using a MAPC Instruction I control the physical axis depending on the position of the virtual one with the CAM editor, but.... where are those CAM points stored? I've looked inside all the tags created and couldn't find ...
<s>[INST] PowerFlex 40 Control from Terminals or 22-COMM-E Summary: A051[6] , P36 ,P38We need a Powerflex 40 to Remote start/reference from 22-Comm-e . Local start/reference from terminals If AO51 =6 and input hi does 22-comm-e control VFD? If A051=6 and input lo does P36 and p38 control VFD? Thanks [/INST] Yes, it wil...
<s>[INST] Kinetix 5700 and STO I have a dual inverter that I want to use STO via ethernet/ip. Can I use a selector switch to an input to a safety PLC and turn off the STO and still be considered safe? [/INST] Hello Fleener You can use a safety selector and connect it to a safety input module that is linked to your safe...
<s>[INST] Could you explain to me what of fuction is about registration swith? Summary: I want to know why we need registration swith? Could you pls expalin to me ? thank you very much [/INST] I mean I don't know what is registration switch for? anybody can help expalain to me? Thanks \\n </s>
<s>[INST] ControlFLASH Plus V1.00.00 is available for download (free) Summary: The next generation of flashing firmware devices is availableAll, ControlFLASH Plus V1.00.00 has been released for download from PCDC. This new flashing firmware tool is free. It allows better firmware lifecycle management and improved produ...
<s>[INST] PowerFlex 750 as CIP drives Summary: Using Powerflex 750 drives as CIP Integrated motion drives Has anyone had any experience using a 755 drive, 20-750-UFB-1 card and a SSI encoder? I cannot get the Logix PLC to configure the drive in a usable way. [/INST] I have! I have! Getting the settings right required s...
<s>[INST] 1336 plus and 1336 Plus 2 serial fault Hi, I have got a couple of drives (1336 plus and 1336 Plus 2) I want to connect (via scanport - 1203-module) to a logix controller. However, some of them give F10-serial fault when the scanport cable is unplugged. This network is only for reading parameters (logging). I'...
<s>[INST] PowerFlex 4(x) Series Remote HIM I'm trying to pick a drive and I want a remote HIM, a process controller sending a 0-10VDC speed reference and an AUTO-MANUAL selctor switch.(Too bad there's no auto-tuning on the PF4 series drives or I would use the internal PID - but that's another story...)The remote HIM ne...
<s>[INST] Error E64 (Kinetix 6000 2094-xxxx-x) Regarding E64 (Kinetix 6000 2094-xxxx-x), it happened in 5 axis of my production line (about 85 axis) Actually we see this issue every week. What we did: 1,For the 1st action, we used tie wrap to fasten feedback cable connector at motor end. This allowed us to run for 1 hr...
<s>[INST] 8720MC F1 fuse blown Summary: 8720MC Regen Power supply keeps blowing F1 fuseWhat do I need to look at for possible causes for the F1 fuse blowing? Is it something inside the Power Supply, or wiring on the outside? We have a master unit and a slave unit and it blows both of them. [/INST] nan \\n </s>
<s>[INST] Ultra 5000 Drive C Programs Failing? We had an issue last night with the Ultra5000 drive failing on one of our Hem presses. The hempress was stuck in the lower position (Manual and Auto). Cycled power to the drive several times but couldn't get devicenet communication. So we eventually swapped the drive. As p...
<s>[INST] Variable frequency drive energy saving calculator Summary: Variable frequency drive energy saving calculatorcan anyone please provide me the excel sheet in which I can calculate the energy saved by adopting the variable frequency drive for the Blower in sewage treatment plant for 120HP motor. [/INST] Contact ...
<s>[INST] command fault on 1746-hstp1 module Keep getting this fault when tring to jog the axis. slc503, 2 1746-hstp1 moduleconnected to md808-128 controller. When through the module book and set it all up, but get a command fault when tring to move axis. Let me know what other info you need to try to help meplease. Th...
<s>[INST] Looking for a name of a part Summary: Trying to figure a name and a function of a part in clients el.cabinetHello! I am trying to figure out what does this component do (in the picture - on the left, gray, named N30.1) and what is its actual name? Sorry for the picture quality, it is the best one I got. [/INS...
<s>[INST] Allen Bradley Power Flex 7000 Password Protection Problem Dear All, I'm using Allen Bradley Power Flex 7000 45KW Inverter in my Industry and facing an issue of Password. My AC Drive is not allow to enter in any parameters list due to password. We did not know the password. Kindly help me how can I access to m...
<s>[INST] 2711P-T15C4D9 Windows CE 6.0 with extended features Hi, I try to understand the difference of the PV 2711P-T15C4D8 and 2711P-T15C4D9. In the discription the ending 9 is marked as Windows CE 6.0 with extended features. Does anyone knows what these extended features are? There is nothing described in the techni...
<s>[INST] 200hp 1336 Plus - Why am I getting an F12 Overcurrent fault at power up? I am getting an F12 overcurrent fault as soon as I power my drive up. The motor has megged good and I have even taken the motor leads off of the drive. Ohm value between each VFD output phase is around 2.0 meg.Things I have checked:- che...
<s>[INST] Problem with touch screen calibration 2711P-T15C22D9P. First step: Terminal Settings, then choose Input Devices>touch screen>Calibration. Second Step: Carefully press and briefly hold stylus on the center of the target. Repeat as the target moves around the screen. The problem is that i don't have a message t...
<s>[INST] 843ES CIP-Safety configuration issue Hi All, I'm new to Rockwell products, hope this is the right forum to post the issue. With one of my customers, we're struggling to configure an 843ES encoder, here are the details. IP/DHCP configuration Our network configuration does not allow the default 192.168.1.xxx su...
<s>[INST] Re: Cut to length Flying Shear Hi,A couple of years ago,I made a very similar application, only using Ultra 5000 and ANSI C programming, and also instead of CAM , I used gearAfter comparing the number of pulses provided by the Aux encoder with the LenghtCount variable, it geared the motor to the encoder, afte...
<s>[INST] FTview10.0 SE. On a button I can Run command with the parameter Language en-US (or some other language) - and then the language is activated. How do I run this command from VBA? [/INST] ou may use the following VBA script: ExecuteCommand Language en-US\n </s>
<s>[INST] Active homing on torque level How does the active homing on torque level work?The typically set for the torque level in the homing tab of the axis properties does not match the torque level the axis is using to do the homing sequence. [/INST] Did you see the Application Manual at this LINK ? It could be usefu...
<s>[INST] 20 COMM D FW VERSION Summary: ERRORS WHEN CHANGING 20 COMM D MODULE WITH DIFFERENT FIRMWARE [/INST] I'm getting some faults related to PORT 5 adapter on a PF70 with device net adapter 20 COMM D, so after troubleshooting it I decided to change 20 COMM D comms adapter, the one that is installed is a 20 COMM D F...
<s>[INST] 825-PD protection Relay I need some explation on the function of the terminals Y-(common),and Y12 (IN1) in the 825-PD protection relay. Do i need to use this terminal for a DOL connection?. [/INST] lukman, the function you may assign to that input, and to the other inputs also, are shown in the 825-PD User Ma...
<s>[INST] Axis Properties - Backlash Reversal Offset Enter the value of the reversal offset for the load in terms of user defined position units. Compensation Window Enter the value for the compensation window in terms of user position units. What Does 'Compensation Window' mean? [/INST] See the Motion System Tuning do...
<s>[INST] PowerFlex400 not starting from Logic(Studio 5000 V24.0) Hello Everyone, Hope your good. This is Waseem, and facing problem with PowerFlex400. I'm controlling it over Ethernet(22-Comm-E) and Studio 5000 V24.0, I have created logic to control the VFD, Mapping also done with it in logic. The main problem is comi...
<s>[INST] Configuring 527 for fan motor application I am currently adding a 527 drive to a L71S PLC via ethernet. I am trying to configure the motion group and I need to know what settings I will need in setting up the axis. [/INST] If you already have the drive configured in the IO tree, you should also have an axis a...
<s>[INST] Ultra 3000 Indexing Drive I am using an Ultra 3000 in a simple positioning application. The drive is set up for Indexing and being commanded to move from a PLC using the Index control inputs. The axis is also being 'homed' using the Homing control inputs. The problem I am having is making the drive fault out ...
<s>[INST] Error code 22 in CAT 160 inverter Hi every body. I have CAT 160 BA01NSF1P1 inverter from AB. I have error code 07 22 . I downloaded manual,but there isn't this error code information.what should I do? [/INST] Fault Code 22 Indication: Drive Reset Description: Stop input not present. Corrective Action: Check s...
<s>[INST] COMMUNICATION PROBLEM WITH A 1394-SJT05-T-RL GMC SERVO DRIVE I HAVE A COMMUNICATION PROBLEM WITH A 1394-SJT05-T-RL GMC SERVO DRIVE. I CAN´T GO ONLINE WITH GML COMMANDER. I CHECK RS-232 INTERFACE CONNECTIONS, PORT CONFIGURATION IN MY PC AND THE SERIAL PORT CONFIGURATION SWITCH BUT I CAN´T GO ONLINE. SERIAL POR...
<s>[INST] Kinetix 300 Vertical Brake Summary: Need information on wiring of control and timing for vertical application with holding brake We have a vertical application. The servo motor has a holding brake. An emergency turn off requires the following sequence (this is easy to achieve in other servos) 1. Press emergen...
<s>[INST] Loadcell feedback to a Kinetix 5700 drive Hello all, Keeping it simple, I am running a servo to a force. I have a loadcell to an Analog input card that feeds MCD instruction to control a MAJ velocity. This works, but I am thinking that a could wire the loadcell directly to the secondary feedback of the K5700 ...
<s>[INST] FTview SE 10.0: How to display (and edit) a different language than the default? I have two languages in my installation. I design in English - but as I sometimes just copy a text box and change the text - then I also need to change the second language. How do I switch the display language in my display edito...
<s>[INST] powerFlex4 f005 error I am using a powerflex4 inverter with 0.75 kw rating 1-phase input and there is an error f005 (over voltage error) is appearing at power up and it is disappear after many tries of clearing the fault and restart it . and when I shut the power off for a time and want to run it again this f...
<s>[INST] Servo motor control Whether the servo motor can be directly controlled by 5069-ob8f / 5069-ob8 DC IO module output. If not, what method should be used to control the servo motor? [/INST] Hello Gary. We have a Servo Control solution in our Kinetix portfolio that can be controlled directly with I/O interface Lo...
<s>[INST] 1747-UIC driver Summary: 1747-UIC dont work in my PC Hi My PC crashed last week, now I'm installing everything again, I tryed the 1747-UIC and had a FTDI FT8U2XX device driver under Universal serial bus controllers but nothing shows up on Com & LTP ports, first I installed from RDS500 cd and then I tryed the ...
<s>[INST] Email Address / Subject of Engage outbound Mails Hi, it would be great to have a more descriptive Email Address for Engage Outbound Mails (e.g. the Daily Consolidated Digest), so that it is easier to define a automatic filter for moving the Mail to a folder. The current address is DoNotReply@rockwellautomatio...
<s>[INST] Rockwell Drives Firmware now secure Summary: Rockwell now uses SecureFlash for drive firmwareIf you purchase a drive new now, it will come with firmware that is digitally signed and thus secure. If you wish to replace an existing drive with a new one, you cannot simply downgrade the firmware by flashing with ...
<s>[INST] When drive is told to decel it stops Summary: when we tell the drive to decel it coast to a stop.I have a power flex 753 drive on a 250hp motor. The machine has been in service for 10 years, but we had a drive go bad a few weeks ago. We installed the new drive loaded the original parameter's back in, and it w...
<s>[INST] Rotary to Linear Motion any Ideas? [/INST] Try a virtual Axis as the position on the linear axis (Axis 1) Axis 2 is the Angular Position of the CAM Create a MAPC to copy the effect of the physical CAM (Look up COS rule to calculate values) Tie Axis 2 to Axis 1 via the MAPC Control the motion via Axis 1 Proble...
<s>[INST] Ultra 3000 Won't communicate I have a set of Ultra3000i drives that will no longer communicate with ultraware. I have tried with my other drives to verify that the problem is not with ultraware settings. Any help would be greatly apprecieated. [/INST] Do you mean you are able to connect to other Ultra drives ...
<s>[INST] Kinetix 5300 Communication I have two Kinetix 5300 drives in a new machine. Connecting to a 1769-L36ERM compactlogix processor version 33. I set the software up as we have in the past for the 350 drives. Both drives have configured IP addresses in the in the range of the processor. On startup the drives show ...
<s>[INST] Safety Instruction Safety L6XS for SafeOff (dual channel Output - single channel feedback input) Hello, I'm looking for a safety instruction in my L62S that can handle the safe-off functionality as follows:- Safe-Off switching done by 2 safety outputs (dual channel) to 2 relays on same SafeOff-board of K6000-...
<s>[INST] power cable high flex for the MPL-B880D-MJ22AA I have found the standard flex power cable for the MPL-B880D-MJ22AA servo motor. What is the part number to order high flex instaed of non-flex power cable? Standard power cable part number 2090-XXNPMP8S03. THANK-YOU [/INST] The part number you need is : 2090-XXT...
<s>[INST] STEP Files Does RA provide .stp files of their components. I would like to use 4983-DC120-03.If I had the solid model, it would be very easy to incorporate the part into my (PRO-E) design. The dwg, dxf, & pdf options under the drawings tab don't help me. [/INST] As far as I know, the .stp files are only avail...
<s>[INST] Problem with SERCOS interface on Ultra3000 Drive. We have a control system that consists of 4 Ultra3000's communicating with an Allen Bradley PLC via a SERCOS fiber optic link. Ever since the initial startup of this unit we have had intermittent communication errors. Well, today they became much less intermit...
<s>[INST] PowerFlex 755 and IPM motor with an encoder Summary: Can’t control the speed of a permanent magnet motorHi, I am trying to control Internal Permanent Magnet Motor (not experienced at all) with Powerflex755 drive and I am lost. Today last thing I was successfully able to do was direction test and auto tune for...
<s>[INST] Kinetix drivers Summary: Load the parameters setting automatically from PLC programHello, 1-Is it possible to load the parameters setting automatically for Kinetix 300 using RS Logix 5000 ? If this possible,explain how to do it? 2-For the Kintix drivers which the parameters loaded automatically from PLC progr...
<s>[INST] How to send an ASCII/telnet command to a IP device by RSLogix 500 Hello, I have a ML1400 and I need to access the data of a Omega device through a Ethernet Network. This Omega device is a coordinator that handles wireless data transmission from a 0-20mA device. You can use a Telnet programs to access the data...
<s>[INST] Heartbeat for Powerflex 70 EC w/ ethernet with Logix Profile Hello, I came acrossed a slight issue today. I have a Powerflex 70EC VFD with ethernet connect to my CLX v16 PLC. The drive was running and I use the DriveStatus_Active bit as my running feedback. In the middle of the drive running, an electrician u...
<s>[INST] PF 400 output current fluctuations Summary: pf400 output current is fluctuation too muchhoping all you are doing great. here is new the problem, PF 400 3-phase 25Hp drive is having issue. in telephonic discussion with site person he told me that there are total 7 drives out of which 2 drives is having issues....