<s>[INST] Motion Tracking Error At Higher Speeds I am interested in a way to reduce the tracking error in a CIP motion application. The system has two PowerFlex 755 drives operating in CIP motion. The master axis is connected via a non-synchronous belt to a press. Attached to the press is an 842E motion encoder, which ... |
<s>[INST] Servos and kinetix 6500 Summary: Problems with motion of servos and kinetix 6500Good morning, I have 4 kinetix 6500 and 4 servos MPM-B1653C-MJ74AA. I have them all on stopped status, and i am using Motion Direct Commands to move them, but i'm having several problems with them. The MDC that I use when in stopp... |
<s>[INST] Powerflex 525 with PWM EDIT: moved to Drive and Motion Community -FL How to control Powerflex 525 with Three-phase motor by PWM or PTO [/INST] The PowerFlex 525 drive comes with a digital input built into the terminal block (terminal 7) able to read pulse train signals up to 100 kHz at 24V. PWM (Pulse Width M... |
<s>[INST] Encoder Noise Feedback Greetings, I have a customer with a unique Torque Prove application. They have installed the PF700 and encoder, along with the cables. The issue is that the encoder feedback cable and drive power cables run in the same cat track and due to the unique nature of this mobile hoisting syste... |
<s>[INST] Drive Executive Summary: About Drive Executive Software Does anybody know whether Rockwell stopped providing Drive Executive Software with RSL5K Professional? Regarrds, --Rahul. [/INST] Rahul, as far as I can see through web sites infos and docs, Drive Executive Lite is still included in the RS5k package. htt... |
<s>[INST] servo drive 2198 H025-ERS Summary: servo drive AOPHi I have some issues on the AOP installation. I have a drive 2198 H025-ERS. I tired to installed AOP and eds file. But after that, I found I need Major Version 7. I only have version 1-5 I am using Studio5000 V29.01 Where can I found a correct one AOP Did I m... |
<s>[INST] Unable to get Ethernet Comms working on Dual Port Ethernet Module - PowerFlex 525 Summary: Dual Port Ethernet Communications Setup ProblemsWe have a problem communicating to our PowerFlex 525 drives using the dual port ethernet interface from the stratix switch. Communication is OK if we use the embedded ethe... |
<s>[INST] PowerFlex 700 20-COMM_E Problem I have hooked up two PowerFlex 700 drives to a ControlLogix processor via a 1756-ENBT card. The drives are the only things that are on the network. The first drive connects but then faults out on a F75 (Port 5 Adapter) fault and the second drive will not connect because of a Co... |
<s>[INST] PF750 Fibers Functions Summary: Looking for a white paper or write-up on the Fibers Functions in the PowerFlex 750 family I'm looking for something more descriptive than is in the 750-PM001 on the fibers functions. Anyone know of any manuals, write-ups, or have an example they would care to share on this? Tha... |
<s>[INST] vfd with panel Summary: vfd panel 7.5hp and 15hpneed a vfd with panel, 7.5hp and 15 hp, allen bradley brand with pressure transmitter feedback look.Is this still available in the market?If it is, anybody who could provide a formal quoatation for us. thanks [/INST] If you look up who your local sales office wo... |
<s>[INST] Harmonic Filter with PowerFlex700 drives Summary: Use one Harmonic Filter with multiple PowerFlex700 drives Hello dears, I am designing a RO system which we are using almost 15 PF700 drives (11KW=10 and 5.5KW=5) in same MCC room. I want to use single Harmonic filter (Low Pass) with all VFDs. My two questions ... |
<s>[INST] PF700 Analog Output I have a project where I am reading output power from a PowerFlex 700 series A VFD (part number 20B D 077 A 3ANNANA0) over the analog output connection. I am scaling this value between 0 and 90 kW. My customer complains that at a no load situation the display from this scaling will be arou... |
<s>[INST] Powerflex700VC Encoder Loss Flt 91 Summary: PowerFlex700VC FLT 91 Encoder Loss FaultGood day! One of our electrical hoists is tripping from time to time with FLT 91 Encoder Loss Fault. Sometimes it happens during lifting and hoisting up/down with or without load and sometimes even without using it. The system... |
<s>[INST] Kinetix Hard Overtravel I need to set the action for hard overtravel to function as Soft Overtravel - that is - allow motion in the opposite direction and automatically clear when the Hard Overtravel switch is no longer contacted. Any ideas? [/INST] Review tech note 21499. Basically, to get off a hardware ove... |
<s>[INST] RIO adapter 1336- MOD-G2 with PF 70 I am replacing a 1336 drive with a PowerFlex 70. The 1336 is controlled by a PLC 5/40 through RIO adapter [/INST] I'm not aware of such a possibility...the only old interfaces that can work with Powerflex 70EC Drives are the Scanport adapters. Here you've to use a 20-COMM-R... |
<s>[INST] MAJ Instruction Jerk Units Hi, I'd like to know what Jerk Units refer to. Especially, about % of time, Units per MasterUnit3, % of time-Master Driven. Let me know the definitions of jerk units, please. Environment: Studio 5000 ver33.01_ MAJ, MAM Instruction Best regard Daniel Kim [/INST] Hi Dong-Uk Kim, See t... |
<s>[INST] Powerful 4 E-STOP I am building a small panel with two(2) powerflex 4 VFD drives.I need to hard wire an e-stop into the drives. How do I do this?I have been told that contactors on the motors are not good and that I can't e-stop electronics. Does that mean I can't e-stop the VFD? The application is small. It ... |
<s>[INST] Setting Home position on an absolute encoder Summary: I don't see where to choose absoluteHello all, I have a MPL-B320P-MJ74AA connected to a Kinetix 350 drive 2097-V34PR5-LM. I need to be able to set the absolute encoder to 0 at the home position. I've read in other posts to go to the Homing tab, but there i... |
<s>[INST] Powerflex 400P Pressure application Summary: run drive at pressure setpointHello, I have been searching for some time but not finding exactly what I am looking for. I have a Power flex 400P drive Cat [/INST] http://literature.rockwellautomation.com/idc/groups/literature/documents/um/22c-um001_-en-p.pdf Take a... |
<s>[INST] PowerFlex 700S Phase I versus Phase II control Summary: which should I choose for a new project? (if there is a choice)Hi, After doing a lot of reading and asking many questions here on this forum, I believe the PowerFlex 700S is the drive best suited for my particular web handling application in which I need... |
<s>[INST] kinetix300 alarm E19 EDIT: Linkified the Sample Code Item for convenience and removed the unlinked URL -FL Hello everyone, I would like to ask you I have a set of Kinetix300 servo, the drive is 2097-V33PR1, the motor is TLY-A220T-HJ62AN, I according to the ID number 96735, Alarm E19 when the servo drive retur... |
<s>[INST] PowerFlex 400 - not operating at low drive signal input voltage? We have a PowerFlex 400 drive that is set for 25Hz at minimum and 50 Hz at maximum. The speed is to be controlled by a 0-10VDC input signal. At 10VDC the drive runs 50Hz, at 5VDC the drive runs 37.5Hz and at 2VDC the drive runs at 30Hz. Anything... |
<s>[INST] MPL Motor Cable Hello, I have an MPL motor with a bayonet connector and a feedback cable used with a speed DIN. Can I use this motor and cable together? In this case I can't use transition cables. I need a solution with the products I have. Thanks, [/INST] Hello, Can you please confirm the full catalogue numb... |
<s>[INST] Powerflex 700 PI control....Help needed Hi I am new to the forums, I hope I'm in the right place to get some help.I have an application using a 110 Kw powerflex 700 inverter (vector) driving a 90kw motor being used as a pump (PD not centrifugal). I have a pressure gauge sending me a 4-20 mA signal which I am ... |
<s>[INST] Connected Components Workbench Developer Edition All, Does any one of you have , any documentation related to CCW Developer edition, that describes the trending facility that the latest version has inbuilt. I am basically looking for the sampling rates, capturing interval etc. The profile & the launch materia... |
<s>[INST] EDS 2011 Error Message Has anyone had trouble while monitoring an E3? I can monitor the parameters for a few seconds and then it just stops giving me error message EDS 2011. It states a communication error, unable to establish connection with the target device. I can monitor again right after but still only f... |
<s>[INST] Powerflex40P with Encoder, Just want Speed Control.... I have an application that uses a PF40P with an Encoder. I want to simply set the speed and am not doing any positioning. I'm guessing that I need to set the unit for PID control with the encoder as the PID feedback. Are there any User Guide that define t... |
<s>[INST] Trouble logging in to other parts of the community? Hi there. We've gotten reports of some Rockwell employees having issues logging in to other parts of the community. We are working hard to fix the login issue and will update you here when we have the issue resolved. Thank you for your patience! Eileen [/INS... |
<s>[INST] PowerFlex 753 with new Main Control board Summary: Having electronic keying issue Had a main board go out in a Powerflex 753. New board says it is v10.2. I can not find the database for this version and when I try to create one it never shows up? I have up to v6.11 on my laptop. Running off of a compactlogix ... |
<s>[INST] Documentation explanation Hello, Here is a copy of the PowerFlex 4 and 40 Technical Data.All communications looks to be present for the PF40, is that true ?I want to use a Modbus RTU link, is it possible without an additionnal board ? Many thanks. Serge. [/INST] Yes, this is true; see also this LINK for more ... |
<s>[INST] error 717-80030003 the path %1 could not be found in rslogix 5000 Has any one ever gotten this message when using RSLogix 5000 Pro?and opening a *.ACD project file? I'm running Windows 2000 and logged on as an administrator. Versions 10, 11, 12, 13, 14, 15, 16, and 17 are all installed on this computer. I use... |
<s>[INST] RsNetworxii EDS Wizard Summary: RsNetworxii EDS Wizard A newer version of the device is already registered on your systemTrying to register devices in RsNetWorxii and I keep getting an error that states that newer version of this device is already registered on your system. It then fails to register the devic... |
<s>[INST] Isolation between Analog common and Digital common Hi, I'm using PowerFlex 40 VFD to drive 1HP motor in delta connection. We are designing a PCB board with microcontroller ADC to measure the voltage between Pin 16 (Analog Output) with respect to pin 14 (Analog common). Also we are planning to power the board ... |
<s>[INST] Servo Motor Life expectancy I am using AB Servo Motor Model [/INST] It is required to call in Tech Support in order to get this information.... :smileysurprised: http://www.rockwellautomation.com/support/index.html - fuzzy logic \\n </s> |
<s>[INST] Kinetix Runtime Clocks. Is there any direct tags/status words that you can use to monitor runtime in the Kinetix CIP drives? Specifically, the Kinetix 5700. Ideally, I am looking for: -Power on time (such as DC Bus charged, but servo not enabled) -Actual runtime (-Servo On/Enabled) I know I can just use the... |
<s>[INST] Installing Drive Guard Option on Enhanced Power Flex 70 Drive We have many power flex 70 drives, some with devicenet, ethernet. Some have encoder feedback, some do not. Some have Drive Guard, some Don't. In an effort to keep from having 5 different drives on the shelf, we had researched and thought we could j... |
<s>[INST] Unwind/Winder Application I have an application that currently has two unwinds, idlers and a winder. Basically, it is a machine that takes two unwind rolls and glues them together to wind them. I am looking at replacing the current air/disk brake control on the unwinds as well as the main drive. There are two... |
<s>[INST] Issue with Powerflex 4 startup I've recently obtained two Powerflex 4 drives. I have connected each to identical wood lathes.The first was a 22AV4P5N104 and it works properly from either the keypad or remote control I've added. I also have a 22AA4P5N104 connected to the second lathe. The issue I have is this ... |
<s>[INST] kinetix 5500 - Demo box 120 VAC Hi, Can a kinetix 5500 be wired to 120 VAC for demo testing? Thanks, Thomas [/INST] The smallest K5500 drive shows a standard input of 195-264 VAC, single phase. It MIGHT work on 120, but I suggest you put a single-phase 120-240 step-up transformer into your demo box. The 2198-... |
<s>[INST] Product offering for replacing a 1388-AV60 What product does RA offer to replace an existing 1388-AV60 [/INST] PowerFlex 20P is a DC drive but I could not find a clear cut document that shows how to intergrate it in place of the 1388-AV60. The manual for the 20P can be found in the literature library. You can... |
<s>[INST] Sercos Protocol Error I am having an issue with a sercos ring randomly dropping out. The ring will get to phase 4 and then lose comms and start the cycle over again. This fault resets itself automatically, but it also stops all motion on that secros ring and causes an fast stop situation on our machine. I pul... |
<s>[INST] 'position' and non position Summary: CIP Motion architecture What is the position and non-position in the IAB software? [/INST] There is no difference in part numbers between position and non-position drives. The difference matters to the communication module which will be talking to the drives. The 1756-EN2X... |
<s>[INST] Single Isolation Transformer Multiple VFDs Summary: Has anyone ever use one big isolation tranformer to feed a panel with multiple VFDs?I have a panel with 11 1HP, 2 3HP, and 1 15HP PF525 drives and I want to use one isolation transformer to protect the power grid from the harmonics generated by the VFDs. I d... |
<s>[INST] PF70 460 volt drive to 230 volt motor I have a 230 volt motor rated at 8.2 FLA. I also have a PF70 460 volt drive rated at 11 amps (20BD011XXXXXXX) I am using this drive to power the 230 volt motor. I will change par 0554 Max voltage to 230 to accomplish this. Do i need to size the 460 volt drive to the FLA o... |
<s>[INST] SMC FW Upgrade I am trying to upgrade the firmware on a SMC drive but can't seem to get it going. Drive Explorer will connect to the drive but won't read the new firmware version and I don't see the SMC on Controlflash. Any advise? [/INST] I guess you're talking about SMC Flex.... :smileytongue: Did you alrea... |
<s>[INST] PowerFlex 525 - Series USB Application slow to open Peripheral Drive. Hi! I have a physical machine with W7 SP1 64 bits operating system, on this machine ControlFLASCH V15.03 is installed, a virtual machine with the same operating system settings with all software installed. I want to use the serial USB appli... |
<s>[INST] Torque Control PowerFlex 700 Hi,The parameter list in PowerFlex 700 AC Drives User Manual Series B, Vector Control Firmware 4.001 & Up Series B, Vector ControlFirmware 4.001 & Up Catalog 20b-um002_-en-p doesnt list the torque control parameters like 526, 527, 528 etc shown in the torque control blcok diagram ... |
<s>[INST] powerflex 755 cip motion drive Summary: absolute encoderUsing Studio 5000 rev 28, Powerflex755 Cip motion drive rev.12.002 with a 20-750-UFB-1 card . I'm working on an application that uses a screw jack to raise a roller in position for a lathe. I need a recommendation for an absolute encoder to use for this ... |
<s>[INST] breakout board connection I am using a breakout board (CN1) part no.2090-U3CBBDM44 (with 24VDC to 5VDC converter).How to wire 24DC to converter,can I tie terminal X-(AUX_COM) and X+(24V_AUX_PWR) to 0V and 24VDC terminals the same with I/O power supply termianl IOCOM and IOPWR? Thanks [/INST] Derek, you may do... |
<s>[INST] Correct way to change a PF drive (ENET) Summary: I need to know which is the best way to make the new drive recognized by PLC when I replace a new one When I have a drive that need to be replace, what i usually did is either these 2 ways : 1. Put the new drive in, config the new IP add, reset the ENET switch ... |
<s>[INST] powerflex 753 and micrologix 1100 messaging Summary: will 500CPU write messages cause EEPROM damage I started messaging a 753 through a 22 com e from a micro 1100 using a 500CPU write message. After doing further research, reading the 22 com e manual, I see all examples show using the CIP Generic write, which... |
<s>[INST] ArmorStart 284GS I/O warning Found I/O warning bit ON in PLC. I could not find anything in AOP in studio 5000. Visually drive dont have red indication. How to find and reset this warning. I/O removed and power recycle tried. No luck. [/INST] nan \\n </s> |
<s>[INST] 180 Powerflex 700VC part number I need a 180Amp PFlex 700 type 1 with external HIM. I need 24V inputs and all the analog outputs available. I need 2 N.O. relay outputs and no communication modules. No braking resistors. Can someone help with this part number. I have this part number (20BD180A3ANNANC0)but not ... |
<s>[INST] Servo catalog number Trying to setup a Ultra 3000 drive (2098-DSD-030-SE) to a MPS-A454OF-MJ52DA servo motor. In module properties I can not find the servo in the motor catalog drop down box. Does this mean the drive and motor are not compatible with each other? According to Rockwells product sheet it is. Any... |
<s>[INST] Let shunt resistor work----K350 I have a 2097-Rx shunt resistor install on a Kinetix 350 But I don't configure the software let shunt resistor work My English is poor, I hope you can understand, thank you [/INST] Open the drive properties (from the IO tree), go to the Power tab, make sure the Bus Regulator Ac... |
<s>[INST] Powerflex 4 horizontal mounting Are there derating factors when mounting a Powerflex 4 horizontal ( sideways ) ? [/INST] David9, is it possible to provide forced air through the drive in the horizontal mounting configuration? Can you add a pancake fan to your enclosure directing air through the drive's coolin... |
<s>[INST] Roll Mill Launcher We have an application that was recently upgraded from an old 1394 multi axis servo to K6K. Two of these axis where geared together during a launching cycle to feed a sheet into a Roll mill. With the 1394 you where able to enable both axis to gear then trigger a start but with K6k when the ... |
<s>[INST] Downloading parameters to Ultra 3000i I am trying to download a parameter file to a Ultra 3000i (2098-DSD-020x) and it is giving me a Can't perform paste operation while Enable input active. I have clicked on the disable all tab and also made sure that the enabled option was not checked under the commands men... |
<s>[INST] PF755 over Ethernet/IP with CompactLogix Summary: How to setup the communication?Hi all, I have 2 PF755 suposelly communication with my CompactLogix. Everything looks ok but when I set the Reference value and the Start bit the drive does not start. I used the 755 Profile in Sudio 5000. Everything seems fine b... |
<s>[INST] EM Brake option for the PF40 Greetings, I have a customer looking to have a brake motor (c/w Electro-Mechanical brake (EM brake)). The digital inputs on the drive have an option for the EM brake release, however that parameter option is not available on my demo. The firmware on my drive is at version 2 levels... |
<s>[INST] Motor starter information Summary: Looking for product specifications and interconnect diagramHello, We have had a particular product that was specified to us for a new system we are building and I cannot find any information on it other than a replacement parts list. The part number that the company gave us ... |
<s>[INST] Integration of LabVIEW and Ultraware for the Ultra 3000 Drive Do any drivers exist which provide an interface between LabVIEW and an Ultra 3000 drive? Or is it possible to use the Ultraware software in conjunction with LabVIEW? Many thanks! [/INST] Hi, and welcome to the Forum ! Well, as far as I know, there ... |
<s>[INST] Mcirologix 1400 Ethernet to Danfoss FC302 Summary: Can I connect to the Danfoss FC302 c/w MCA121 kit onboardHello I have been reading the Danfoss manual on the MCA121 EIP card and it refers to connection with RS Logix 5000 later than version 20.0 Do you know if I can connect a 1400 using RSlogix 500 EIP or am... |
<s>[INST] Spara parts of PF700S Please, where can I find information about spare parts corresponding to PowerFlex 700S, like list spare parts, delivery time and quotation, the catalogue number is:20DD385A0ENNBNANE Please, Can You help me? with some information. [/INST] Please have a look to the following link, there is... |
<s>[INST] PF750 Drives | Dual Loop Control EDIT: linkified technode URL for convenience -FL Hello, I have read that dual loop control is support with the PowerFlex 755 AC Drive. Does anyone have experience with the application? As far as I researched, only UFB card supports it. In this card, I know that incremental enc... |
<s>[INST] Kinetix 6000 E36 and E72 Faults Summary: What temperatures do you see these faults?Approximately what internal temperature in a Kinetix 6000 would indicate an E36, drive converter overtemperature or an E72, drive inverter overtemperature? [/INST] Per the manual, the environmental operating range is 0-50C. If ... |
<s>[INST] Can Ultra 100 series drive with DeviceNet be used without DeviceNet interface? After looking through the user manual, I'm unable to determine if an Ultra 100 series drive with the DeviceNet interface can be setup and operated like a standard 100 series drive without using the DeviceNet interface. Anyone know?... |
<s>[INST] Loading motion programs into an IMC-110 module using ODS and a PIC I have a customer with an older SLC-503 machine that lost memory from the IMC-110 motion module. We have the .amp programs, the old ODS floppy's and a PIC, but it's been fifteen years since I've used ODS. I have some old AB documentation, but ... |
<s>[INST] Drive speed, Devicenet Hi, I have a PowerFlex 700 connected in Devicenet, I want to change the speed from a PV+ who is connected to a compactlogix L35E (through ETH)... I know how to program the parameters of start-stop, faults, active and other easy conditions in the scanner module using RSLogix 5000 and RSN... |
<s>[INST] Multiple Motion Groups Summary: Why can't you make more than 1 Motion Group in Control Logix 5000? Why are there Motion Groups if you can't have more than 1? It would be nice to be able to make more than 1. As it stands, you can only issue a group command if you want all of your axis to act on it. [/INST] Wel... |
<s>[INST] Power Flex 40P What is the component DP 51 ? [/INST] I think you've to add more details on what you're searching for.... where did you see that code ? Is it on the Control Board ? The more infos and details you put in your posts, the more help you may expect to receive... :smileywink: - fuzzy logic \\n </s> |
<s>[INST] Optix Multiple Fill Colors. I have a simple rectangle that I am wanting to fill will 3 different colors based on an integer. I am trying to utilize the KeyValueConverter for this task and converting the integer to a string value. Obviously, this is not working for me. Any suggestions are greatly appreciated.... |
<s>[INST] SMC-3 control terminal question I have a really basic question on some new SMC-3 (150-C16NBD) softstarts I am installing: How are IN1 & IN2 used? I dont understand how they work or what they are. The datasheet does not say. Thanks! Jeff [/INST] See the following technotes... Aid 62695 - Aid 62696 - Aid 24364 ... |
<s>[INST] Power Flex 700S - failure to turn on Good evening, I have this problem with a PowerFlex 700S VFD, from time to time, but not always. When I power up the VFD the display stays in Connecting to, and I can only correct it by turning it off and on again, sometimes up to 2 or 3 times. And it only happens every tim... |
<s>[INST] powerflex 4 control net why can't i upload parameters from drive in rslogix 5000 ver 16 using cnet? I can't see the drive, all i see is the 1756-cnb card and i cant choose a drive. [/INST] Make sure your drive has been added to your I/O configuration under the CNB card responsible for the drive. Also, when yo... |
<s>[INST] POWERFLEX 700S FAN Summary: SHOULDN'T FAN STOP WHEN VSD IS ON IDLE?Hello experts, I have got 13 (thirteen) 355kW VSDs and when they are in idle mode the cooling fans remaining running all the time. I have before worked with SIEMENS MASTERDRIVES and MICROMASTERS SIEMENS MASTERDRIVES the fan will only start whe... |
<s>[INST] Powerflex 700 fault 121 I am experienceing this fault and did a search of the forum and found this, but it was left unresolved. http://forums.rockwellautomation.com/t5/forums/forumtopicpage/board-id/Drives/message-id/2212 . I was wanting to see if anyone has found a resolution to this fault. I have replaced a... |
<s>[INST] Log of faults is not updating I have a system with kinetix 6000 and Controllogix, but in the feedback structure for each drive in the processor is not updating the log when a fault happens. What could be the problem?, how do i solve it?. [/INST] What type of fault are you getting (can you see a flashing 'E' f... |
<s>[INST] 1756-HSC Do we have to tie the 24vdc common to card and if so where do we do that? [/INST] It depends... if you have a Differential Line Driver encoder, you don't need 24 Vdc common.If you use a different source, the Common should be connected to the RET terminal of the input you use (A,B). Aid 41188 See also... |
<s>[INST] ultra 3000 sercos loosing enable Summary: loosing enable signal and no faultsI have a client with 4 drives on Sercos. all 4 drives have same hard wired enable signal. Drive [/INST] Are you running this via ControlLogix and RS5000? You could use the trending tool (a software scope) to track a number of tags as... |
<s>[INST] PF70 speed command Is it possible to use analog input 1 as the main speed command for a PF70 with analog input 2 as a trim.ie multiply the required speed of analog 1 by the % of analog 2.For example if analog 1 is 12 mA (4-20mA input) then this is half speed.Then if analog 2 is 2.5V (0-10V input) then the spe... |
<s>[INST] SERCOS IDN Messaging Can anyone provide a list of IDNs that can be read/written to Kinetix 6000?The configuration dialog for the MSG requires a 'Identification Number:' and 'Element:'. I cannot find these values documented. As a specific case, I am trying to read/write the bus capacitance parameter (parameter... |
<s>[INST] How force AOI local tags. For testing and commissioning, I have to force many AOI local tags. How to do it. There any many bit level XIC in the AOI instant and each to be toggled permanently to start AHU fan. [/INST] If the local tags are exposed as external access, then you can toggle them on the HMI via FTL... |
<s>[INST] CIP Module Fault - 755/53 & EN3TR Getting random module sync faults that can only be reset by completely powering down the drive. Only thing on the EN3TR network is drives and an HMI. Anyone else have this problem? Don't seem to have the issue with the Kinetix 6500 drives on the same network, just the PowerFl... |
<s>[INST] PF525 Rating Table Object? Hi all, I'm reworking an AOI I wrote for the PowerFlex 525 and am diving into the DPI objects documented in 520com-um001_-en-e.pdf. One parameter I originally put to use to establish parameter ranges is D367 [Drive Type]. I made use of QA20724 to get rated horsepower, power, current... |
<s>[INST] Transaction Manager V13.10 String data issue. last week FTTM V13.10 installed and tested with 1756-L71 PLC V24. I am able to write data from PLC to SQL table. I am trying to read data from SQL table using stored procedures method. Compare string from PLC tag with SQL table. When configure string instead of P... |
<s>[INST] flashing green led on Sercos interface 1756-M16SE Summary: flashing green led on Sercos interface 1756-M16SEi have a flashing green led on a Sercos interface 1756-M16SE module, on which one drive axis was removed physically, deleted from the program with successful download. i checked the manuals and found th... |
<s>[INST] PF400: Motor Overload Tripping Problem. Hi all, I am facing one problem in PF 400 drive while setting P033 [Motor OL Current] parameter. I want drive to be tripped on 220 Amp. As per manual the drive will fault on an F7 Motor Overload if the value of this parameter P033 [Motor OL Current] is exceeded by 150% ... |
<s>[INST] Powerflex 525 Summary: My drive is putting out 24v on my safe inputsMy drive is putting out 24v on my safe inputs, I'm trying to input the 24v from a relay. Is there a parameter that I can change in the drive that will stop the drive from outputting and take an input? [/INST] Page 239 of the user manual: http... |
<s>[INST] What is the use of Program mode and Test mode over Run mode in rockwell PLC. [/INST] Run mode is the normal mode of operation. Test mode is a version of Run mode. You can make online edits, Accept them, then go into Test mode and see if they work as expected. Then you have the choice to finalise and keep the... |
<s>[INST] Kinetix 5500/5700: Error 16#080e Safety network number mismatch. After swapping of two Kinetix 5500/5700 Servo Drives and assigning of new IP Addresses, the modules show error code 16#080e Safety network number mismatch in Studio 5000 Logix Designer Software. An attempt to Reset Ownership from the Safety tab ... |
<s>[INST] SMC Flex Start Stop Summary: Soft Starter wont start We have an SMC Flex Soft connected to the L23E PLC via Ethernet ( 20 Comm E card ). The sofstarter Display/Control has firmware revision 6.006. When commanded to start with LogicCommand_Start, it does start up but when commanded to stop with LogicCommand_St... |
<s>[INST] 2HP PF755 Motor Speed Varying with Encoder Feedback Summary: Closed Loop Speed Control is PoorHello. I have been getting beat-up by this drive path over the past few weeks. It is a 2HP/480V/1750rpm application with a PF755/2HP connected to a known well-performing Marathon Blue Max 1024 Quad Encoder-Feedback m... |
<s>[INST] Kinetix 5700 - 2198-D006-ERS4 v13.003 - EDS File Summary: EDS file for v32.03Hello, I am looking for the EDS file for the kinetix 5700 2198-D006-ERS4 in version 13.003 for Logic Designer v32.03. On the rockwell support there is marked that these versions are compatible. However, I cannot select a version grea... |
<s>[INST] Kinetix 6000 Flash Programming Summary: How to flash ancient hardware to current I have several drives in a system which are 2094-BC02-M02 and 2094-BM01 units, RSlogix 5000 reports them as Revision 1.75 while RSlinx reports them as Revision 1.075. According to the documentation I have been able to find 1.85 /... |
<s>[INST] 160 Drive DeviceNET interface Summary: DeviceNET interface retain settings? We have a facility in Malaysia that has several 160 drives on DeviceNET that have failed. They do not have RSNetworx, or the experience to use it if they purchased a copy. We have here a few of these drives that were pulled from older... |
<s>[INST] PF400 powering up in Hand mode I have 2 PF400 7.5hp drives, one of them keeps booting up in Hand mode after a power outage.I recorded the basic parameters :p031-460, p032-60, p033-12, p034-15, p035-60, p036-003, p037-001, p038-002, p039-150, p040-20, p042-002What other parameters should I look at that could p... |
<s>[INST] Allen-Bradley Power Flex 4 I was involved in a project that required three conveyors to run at the same speed and the engineer suggested that we connect three motors in parallel, connected to an A-B PowerFlex 4. When we tried to run the drive it acted very strange. Two of the motors were rated at .8 amps and ... |
<s>[INST] Setting servo torque limit Running Kinetix SERCOS drives with MPL motors They were at 40% constant and 50% peak. They were faulting out when trying to home. They said they could find no mechanical issues. I bumped the peak up to 60% and then 75% to get them going, and they later found some minor mechanical is... |
<s>[INST] How to reset motion instruction error? For example, if MSO instruction's error bit has been set for some reson, how to reset or clear it in PLC without drive or PLC power recycle? [/INST] Please try to take a look first to the Motion Instructions Reference Manual - Chapter 1 (Motion Concepts) about the behavi... |